“New evolution with high density cooling solutions by CITEC” CITEC INTEGRATED RACK INTRODUCTION Nowadays, the cooling of computer and telecommunication equipment rooms is becoming a major challenge because of the increasing compactness of data processing equipment. While the industry struggles to address various of these problems and others, Citec’s has designed Citec Integrated Rack (CIR) as a new evolution of cooling solutions for data centers worldwide. This rack leads the way in thermal management and allows companies to: • Fully populate server racks and increase power density with significantly improving energy efficiency. • Decrease power costs. • Revolutionize how data centers are designed, built, and operated. • Increase the computing power in data centers. • Decrease server failure due to heat damage. With High Density Heat Containment (HDHC) technology, data centers can be utilized or built in a substantially more efficient manner to save upfront costs and reducing operating costs. FEATURES • Fan integrated for easy installation and deployment • Pressure transmitter to monitor real time differential air pressure • NTC temperature sensors to monitor real time both inlet and outlet air temperature • Auto reset thermal overload protection on fan motor and power supply • Remote ON/OFF switch (optional) • Ducting (optional) • Alarm notification CITEC INTEGRATED RACK RACK • Finished high quality powder coated • Integrated with fan • Four-post racks allow for mounting slides to support the equipment at the front and rear • Up to 42U high • Compliant standard for 19 inch equipment • Panel mounting various international standards • Lockable blanking rear swing door • Lockable detachable panels • Side vertical metal cable management panel • Perforated front door • Base frame with cable entry access Front View DISPLAY • LCD Display located at front panel • User friendly navigation mode • Push buttons for unit ON/OFF SERVICE ENTRY / ACCESS REQUIREMENT • Front service for easy maintenance access and fan removable • Simple sliding fan mechanism • Fan replacement can take place while other fan is in operation • Electrical section located at the front of the rack • High and low voltage wiring segregation CITEC INTERNATIONAL SDN. BHD. “Contain the heat and improve the data center efficiency” HOW IT WORKS Hot air goes back to cooling unit Fan ensure hot air being extracted out of the rack effectively. * the duct is an option Electrical section Solid rear panel Cold air Raised floor The heat containment utilizes a physical barrier to contain the IT equipment heat and provide a predictable pathway for its return to the data center cooling units. The cool air is delivered to the IT equipment through the raised floor perforated tiles. Heated exhaust air from the IT equipment can be removed from the rear of the rack using high flow low power fans. The air is then ducted to the ceiling plenum for return to the cooling units. In this arrangement, the maximum amount of cool air will be available to the IT equipment load while all waste heat is contained and return to the cooling units. BENEFITS OF HDHC SYSTEM • No hot aisle, the whole data center is cold • Higher return air temperature to Precision Air Conditioner (PAC), increase PAC cooling capacity • Smaller PAC models can be used to provide cost saving and energy efficiency • No cold spot because of supply air is at design rack inlet air • Consistent temperature at rack intake from bottom to top • Lower RH return air improve sensible heat ratio “Designed to fulfill the requirements of modern day high density data center” ADVANTAGES • To boost data centre reliability • Optimize current cooling infrastructure • Reduce or eliminate PAC over-provisioning by providing physical separation of cool supply and hot return air streams • Restore PAC capacity for needed IT equipment loads by eliminating air recirculation and by pass • Round the clock operation with full performance • Redundancy fan design TECHNICAL DATA CIR3000E CIR3000A Supply Voltage Max Air Flow (m3/h) Rate Current* 3000 1.65A Max Power Consumption* Fan Type CIR1500E CIR1500A 230 +/- 10% VAC 1500 1.95A 1.00A 1.30A 285W 334W 180W 208W EC Axial Fan AC Axial Fan EC Axial Fan AC Axial Fan Working Temperature Working Humidity Physical Dimension (mm) Racks Info -10°C to 60°C 20% to 90% RH 800 (W) X 1000 (D) X 2335 (H) Four-post Type High Up to 42U Standards 19" Equipment Racks Accessories (Option) Power Distribution Equipment Tray Sliding Tray Blank Panels Adjustable Feet Rear View Ducting * the data shown is rated at 230VAC, 50Hz All information, including illustrations, contained in this brochure, is believed to be accurate and reliable. Users, however, should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. CITEC INTERNATIONAL SDN. BHD. (372827-H) No. 47, (PT 63846), Lorong Jala 14/KS10, Telok Gong, 42000 Port Klang, Selangor Darul Ehsan, Malaysia. Tel: 603-3134 2668 Fax: 603-3134 2648 Email: enquiry@citec.com.my Version 1.0 / 2009 / CIR 01 Due to our policy of continuous development and improvement, the specifications and data herein are subject to change without notice. We must therefore reserve the right to supply equipment that may differ from that described and illustrated herein. www.citec.com.my