CITEC INTEGRATED RACK

advertisement
“New evolution with high density cooling solutions by CITEC”
CITEC INTEGRATED RACK
INTRODUCTION
Nowadays, the cooling of computer and telecommunication equipment
rooms is becoming a major challenge because of the increasing
compactness of data processing equipment.
While the industry struggles to address various of these problems and
others, Citec’s has designed Citec Integrated Rack (CIR) as a new
evolution of cooling solutions for data centers worldwide.
This rack leads the way in thermal management and allows companies to:
• Fully populate server racks and increase power density with
significantly improving energy efficiency.
• Decrease power costs.
• Revolutionize how data centers are designed, built, and operated.
• Increase the computing power in data centers.
• Decrease server failure due to heat damage.
With High Density Heat Containment (HDHC) technology, data centers
can be utilized or built in a substantially more efficient manner to save
upfront costs and reducing operating costs.
FEATURES
• Fan integrated for easy installation and deployment
• Pressure transmitter to monitor real time differential air pressure
• NTC temperature sensors to monitor real time both inlet and outlet air
temperature
• Auto reset thermal overload protection on fan motor and power supply
• Remote ON/OFF switch (optional)
• Ducting (optional)
• Alarm notification
CITEC INTEGRATED RACK
RACK
• Finished high quality powder coated
• Integrated with fan
• Four-post racks allow for mounting slides to support the
equipment at the front and rear
• Up to 42U high
• Compliant standard for 19 inch equipment
• Panel mounting various international standards
• Lockable blanking rear swing door
• Lockable detachable panels
• Side vertical metal cable management panel
• Perforated front door
• Base frame with cable entry access
Front View
DISPLAY
• LCD Display located at front panel
• User friendly navigation mode
• Push buttons for unit ON/OFF
SERVICE ENTRY / ACCESS
REQUIREMENT
• Front service for easy maintenance access and fan removable
• Simple sliding fan mechanism
• Fan replacement can take place while other fan is in operation
• Electrical section located at the front of the rack
• High and low voltage wiring segregation
CITEC INTERNATIONAL SDN. BHD.
“Contain the heat and improve the data center efficiency”
HOW IT WORKS
Hot air goes back
to cooling unit
Fan ensure hot air
being extracted out of
the rack effectively.
* the duct is an option
Electrical section
Solid rear panel
Cold air
Raised floor
The heat containment utilizes a physical barrier to contain
the IT equipment heat and provide a predictable pathway for
its return to the data center cooling units. The cool air is
delivered to the IT equipment through the raised floor
perforated tiles. Heated exhaust air from the IT equipment
can be removed from the rear of the rack using high flow
low power fans. The air is then ducted to the ceiling plenum
for return to the cooling units. In this arrangement, the
maximum amount of cool air will be available to the IT
equipment load while all waste heat is contained and return
to the cooling units.
BENEFITS OF HDHC
SYSTEM
• No hot aisle, the whole data center is cold
• Higher return air temperature to Precision Air
Conditioner (PAC), increase PAC cooling
capacity
• Smaller PAC models can be used to provide
cost saving and energy efficiency
• No cold spot because of supply air is at design
rack inlet air
• Consistent temperature at rack intake from
bottom to top
• Lower RH return air improve sensible heat ratio
“Designed to fulfill the requirements of modern day high density data center”
ADVANTAGES
• To boost data centre reliability
• Optimize current cooling infrastructure
• Reduce or eliminate PAC over-provisioning by providing physical
separation of cool supply and hot return air streams
• Restore PAC capacity for needed IT equipment loads by eliminating air
recirculation and by pass
• Round the clock operation with full performance
• Redundancy fan design
TECHNICAL DATA
CIR3000E
CIR3000A
Supply Voltage
Max Air Flow (m3/h)
Rate Current*
3000
1.65A
Max Power Consumption*
Fan Type
CIR1500E
CIR1500A
230 +/- 10% VAC
1500
1.95A
1.00A
1.30A
285W
334W
180W
208W
EC Axial Fan
AC Axial Fan
EC Axial Fan
AC Axial Fan
Working Temperature
Working Humidity
Physical Dimension (mm)
Racks Info
-10°C to 60°C
20% to 90% RH
800 (W) X 1000 (D) X 2335 (H)
Four-post Type
High Up to 42U
Standards 19" Equipment
Racks Accessories
(Option)
Power Distribution
Equipment Tray
Sliding Tray
Blank Panels
Adjustable Feet
Rear View
Ducting
* the data shown is rated at 230VAC, 50Hz
All information, including illustrations, contained in this brochure, is believed to be accurate
and reliable. Users, however, should independently evaluate the suitability of each product
for their own application. CITEC makes no warranties as to the accuracy or completeness of
the information, and disclaims any liability regarding its use.
CITEC INTERNATIONAL SDN. BHD. (372827-H)
No. 47, (PT 63846), Lorong Jala 14/KS10, Telok Gong,
42000 Port Klang, Selangor Darul Ehsan, Malaysia.
Tel: 603-3134 2668 Fax: 603-3134 2648
Email: enquiry@citec.com.my
Version 1.0 / 2009 / CIR 01
Due to our policy of continuous development and improvement, the specifications and data
herein are subject to change without notice. We must therefore reserve the right to supply
equipment that may differ from that described and illustrated herein.
www.citec.com.my