Smart Solutions Intelligent, integrated infrastructure for the data center 1 Smart Solutions Family 2 Smart Solutions From Emerson Network Power An integrated data center infrastructure – Power, Cooling – Racks, Power Distribution – Infrastructure and IT Management What makes these solutions unique? Efficient Economical Interoperable Control • Enhance business, space, energy efficiency • Rapid deployment, easy servicing • Make use of existing infrastructure • Avoid expensive room upgrades • Simple and flexible design and implementation • Systems work together • Optimized planning, monitoring and management • Control your IT environment 3 SmartRow TM 4 Introducing SmartRow TM Intelligent, integrated infrastructure in a self contained line-up Needs Addressed Applications • • • • Capacity: 20kW Racks: 3-6 Floor: Primarily non-raised Key Applications: Small data centers; remote sites • • • • • Integrated design Standardization Low 1st cost & operating cost Availability Speed of deployment 5 SmartRow - What is it? TM Single line of racks Complete and integrated data center infrastructure – 3-6 racks (up to 20kW) – Integrated Cooling – Airflow Management – Fire Suppression – UPS – Power Distribution Liebert Challenger – Monitoring – Downflow 5-Ton – Air, Water/Glycol or Chilled Water 6 SmartRow – Airflow Management TM 7 SmartRow Benefits TM Efficient • Significant energy savings from enclosed precision cooling system, variable capacity and intelligent controls • Optimizes space efficiency through integrated system Economical • Room neutral: No effect on existing space • Reduce cost of installation: no need to undertake expensive upgrades to fire suppression, cooling capacity or flooring Interoperable • Can be deployed in just weeks: simple in design & deployment • Local data center experts and service teams for configuration, installation, maintenance, repair Control • Monitors temperature and controls precision cooling operating levels accordingly • Monitors equipment for quicker response & resolution 8 SmartRow Design & Cost Example TM Situation: deploy 18 kW of IT to a non-IT ready room Conventional Design 18 kW, 288 sq ft 1 rows, 6 racks Ceiling mounted ducted cooling (6) 5 kVA UPS Room renovation, fire suppression SmartRow 18 kW, 288 sq ft 1 rows, 6 racks 1 Liebert Challenger (downflow) 6 Liebert GXT 5 kVA Room neutral 9 SmartRow Cost Comparison TM Conventional SmartRow Cost Savings % Savings $60,000 $43,000 $17,000 28% $105,000 $109,000 -$4,000 -3% $165,000 $152,000 $13,000 8% $8,800 $6,400 $2,400 27% 5 Year OpEx $44,000 $32,000 $12,000 27% 5 Year TCO $209,000 $184,000 $25,000 12% Room Costs contractor, installation, engineering services Infrastructure Equipment UPS, distribution, cooling, racks, fire suppression Total CapEx Annual Energy Consumption power & cooling equipment energy use Room Savings Room neutral, fewer services to retrofit room into an IT space Equipment Savings Pre-engineered, integrated precision cooling, ducting, distribution and fire suppression Energy Savings Airflow management, variable capacity, intelligent controls 10 Smart Solutions - Summary Smart Solutions SmartRowTM SmartModTM SmartAisleTM Ideal Applications Non-traditional space Disaster recovery Non-traditional space Disaster recovery Auxiliary capacity Data Center High Density Pod 20 kW 30-90 kW 200-400 kW Most cost effective up to 400 kW kW per Rack 2 to 6 kW / rack 5 to 14 kW / rack 5 to 30 kW / rack Key Benefits Fully integrated, standalone roomneutral system All in one design, just add servers and network connection Standardized solution building blocks Capacity Example Layout 11 Smart Control Liebert Precision Cooling Strategy Strategies for Energy Efficiency How do we get the most out of the cooling equipment? 4 Strategies 1. Maximize the Temperature Back to the Cooling Unit 2. Match Cooling Capacity & Airflow with the IT Equipment 3. System Design to Reduce Component Power 4. Use Networking and Monitoring Tools So Units Can Work Together 1. Maximize the Temperature Back to the Cooling Unit ---- Chilled Water CRAC ---- Direct Expansion CRAC Higher return air temperatures increases the cooling unit capacity Higher Precision Cooling unit ΔT & SHR Recovers stranded capacity Efficiency gain from 15% to 20% Steps - Actions that maintain Cooling Reliability: 1. Controlled separation of Hot and Cold air streams Perimeter Cooling Row Cooling 2. Move to Supply Air temperature control Return Air Temperature control is now meaningless Precision is controlling the air temperature to the servers Liebert is the sole leader in this control technology 2. Manage the Airflow to the Server Too Much Flow – Waste of Energy Too Much Little – Unreliable Under floor Pressure control or just supply only control 16 2. Match Cooling Capacity & Airflow with the IT Equipment Eliminate the excess airflow by controlling the cooling capacity and the supply airflow independently Cooling Unit Capacity (kW) = Server Load (kW) Cooling Unit Airflow = Server Airflow Efficiency benefit of 10% to 15% 100% 0% Compressor Fans 3. System Design to Reduce Component Power A. Reduce Cooling Unit Fan power VFD and EC Fans Full Fan Speed 100% Part 80% Load Energy Savings 0% 10% 30% 30% 40% 65% Liebert XD - at the source with smaller fans or no fans results in: 1. Fan component – 65% to 100% lower 2. System benefit of 25% 3. System Design to Reduce Component Power B. Minimized Compressor hours of operation with Economization modes Location and Data Center operating condition dependant Wide range of benefits from 12% to 35% on the system Use the TCO model to make the right choice 4. Use Networking and Monitoring Tools So Units Can Work Together Teamwork: In operation Use monitoring and optimization tools to improve efficiency Benefits of cooling units working together – Share data between multiple units to ensure that servers only get what they need – Avoid conflict between units, i.e. disallow dehumidification if humidification is the proper operation Liebert iCOM™ Application Control SmartAisle™ -control Managing the Cooling to the Server Group Control Teamwork Cooling System Efficiency Unit Control Advanced Performance, Diagnostics and Efficiency 21 Containment Comparison <<Without containment With containment>> 22 Smart Aisle Overview • Smart Aisle is a control mode that allows iCOM to manage air flow and cooling capacity independently. • Smart Aisle is a server centric solution meaning that it focuses on the inlet temperature to the servers • As the environment changes due to server utilization, equipment location changes and outside variables so does the iCOM controller • Adapts from no containment to end containment to full containment 23 Cold Aisle Containment - SmartAisle™ Integrated Containment Benefits Control with iCOM Match Cooling and Airflow to IT equipment delta T to eliminate waste iCOM will vary the fan speed independently with Liebert DS and Liebert CW to match server ΔT to eliminate bypass air Other benefits Higher rack density ~ 12kW Recover stranded cooling capacity Less dependant on open floor tile placement 24 Q&A 25