Smart Solutions
Intelligent, integrated
infrastructure for the data center
1
Smart Solutions Family
2
Smart Solutions
From Emerson Network Power
 An integrated data center infrastructure
– Power, Cooling
– Racks, Power Distribution
– Infrastructure and IT Management
What makes these solutions unique?
Efficient
Economical
Interoperable
Control
• Enhance business, space, energy efficiency
• Rapid deployment, easy servicing
• Make use of existing infrastructure
• Avoid expensive room upgrades
• Simple and flexible design and implementation
• Systems work together
• Optimized planning, monitoring and
management
• Control your IT environment
3
SmartRow
TM
4
Introducing SmartRow
TM
Intelligent, integrated infrastructure in a self contained line-up
Needs Addressed
Applications
•
•
•
•
Capacity: 20kW
Racks: 3-6
Floor: Primarily non-raised
Key Applications: Small data
centers; remote sites
•
•
•
•
•
Integrated design
Standardization
Low 1st cost & operating cost
Availability
Speed of deployment
5
SmartRow - What is it?
TM
 Single line of racks
 Complete and integrated
data center infrastructure
– 3-6 racks (up to 20kW)
– Integrated Cooling
– Airflow Management
– Fire Suppression
– UPS
– Power Distribution
 Liebert Challenger
– Monitoring
– Downflow 5-Ton
– Air, Water/Glycol or
Chilled Water
6
SmartRow – Airflow Management
TM
7
SmartRow Benefits
TM
Efficient
• Significant energy savings from enclosed precision cooling
system, variable capacity and intelligent controls
• Optimizes space efficiency through integrated system
Economical
• Room neutral: No effect on existing space
• Reduce cost of installation: no need to undertake expensive
upgrades to fire suppression, cooling capacity or flooring
Interoperable
• Can be deployed in just weeks: simple in design &
deployment
• Local data center experts and service teams for configuration,
installation, maintenance, repair
Control
• Monitors temperature and controls precision cooling operating
levels accordingly
• Monitors equipment for quicker response & resolution
8
SmartRow Design & Cost Example
TM
Situation: deploy 18 kW of IT to a non-IT ready room
Conventional Design
18 kW, 288 sq ft
1 rows, 6 racks
Ceiling mounted ducted cooling
(6) 5 kVA UPS
Room renovation, fire suppression
SmartRow
18 kW, 288 sq ft
1 rows, 6 racks
1 Liebert Challenger (downflow)
6 Liebert GXT 5 kVA
Room neutral
9
SmartRow Cost Comparison
TM
Conventional
SmartRow
Cost Savings
% Savings
$60,000
$43,000
$17,000
28%
$105,000
$109,000
-$4,000
-3%
$165,000
$152,000
$13,000
8%
$8,800
$6,400
$2,400
27%
5 Year OpEx
$44,000
$32,000
$12,000
27%
5 Year TCO
$209,000
$184,000
$25,000
12%
Room Costs
contractor, installation, engineering services
Infrastructure Equipment
UPS, distribution, cooling, racks, fire suppression
Total CapEx
Annual Energy Consumption
power & cooling equipment energy use
Room Savings
Room neutral, fewer services to retrofit room
into an IT space
Equipment Savings
Pre-engineered, integrated precision cooling,
ducting, distribution and fire suppression
Energy Savings
Airflow management, variable capacity,
intelligent controls
10
Smart Solutions - Summary
Smart Solutions
SmartRowTM
SmartModTM
SmartAisleTM
Ideal Applications
Non-traditional space
Disaster recovery
Non-traditional space
Disaster recovery
Auxiliary capacity
Data Center
High Density Pod
20 kW
30-90 kW
200-400 kW
Most cost effective
up to 400 kW
kW per Rack
2 to 6 kW / rack
5 to 14 kW / rack
5 to 30 kW / rack
Key Benefits
Fully integrated,
standalone roomneutral system
All in one design, just
add servers and
network connection
Standardized
solution building
blocks
Capacity
Example Layout
11
Smart Control
Liebert Precision Cooling Strategy
Strategies for Energy Efficiency
How do we get the most out of the
cooling equipment?
4 Strategies
1. Maximize the Temperature Back to the Cooling Unit
2. Match Cooling Capacity & Airflow with the IT Equipment
3. System Design to Reduce Component Power
4. Use Networking and Monitoring Tools So Units Can
Work Together
1. Maximize the Temperature Back to
the Cooling Unit
---- Chilled Water CRAC ---- Direct Expansion CRAC
 Higher return air temperatures
increases the cooling unit capacity
 Higher Precision Cooling unit ΔT &
SHR
 Recovers stranded capacity
 Efficiency gain from 15% to 20%
Steps - Actions that maintain Cooling Reliability:
1. Controlled separation of Hot and Cold air streams
 Perimeter Cooling
 Row Cooling
2. Move to Supply Air temperature control
 Return Air Temperature control is now meaningless
 Precision is controlling the air temperature to the servers
 Liebert is the sole leader in this control technology
2. Manage the Airflow to the Server
Too Much Flow – Waste of Energy
Too Much Little – Unreliable
Under floor Pressure
control or just supply
only control
16
2. Match Cooling Capacity & Airflow with
the IT Equipment
 Eliminate the excess airflow by controlling the cooling
capacity and the supply airflow independently
Cooling Unit Capacity (kW) = Server Load (kW)
Cooling Unit Airflow = Server Airflow
 Efficiency benefit of 10% to 15%
100%
0%
Compressor
Fans
3. System Design to Reduce Component
Power
A. Reduce Cooling Unit Fan power
VFD and EC Fans
Full
Fan
Speed
100%
Part
80%
Load
Energy Savings
0%  10%  30%
30%  40%  65%
Liebert XD - at the
source with smaller fans
or no fans results in:
1. Fan component – 65%
to 100% lower
2. System benefit of 25%
3. System Design to Reduce
Component Power
B.
Minimized Compressor hours of operation with Economization modes
 Location and Data Center operating condition dependant
 Wide range of benefits from 12% to 35% on the system
 Use the TCO model to make the right choice
4. Use Networking and Monitoring
Tools So Units Can Work Together
Teamwork: In operation

Use monitoring and optimization tools to improve efficiency

Benefits of cooling units working together
–
Share data between multiple units to ensure that servers only get
what they need
–
Avoid conflict between units, i.e. disallow dehumidification if
humidification is the proper operation
Liebert iCOM™
Application Control
SmartAisle™ -control
Managing the Cooling
to the Server
Group Control
Teamwork
Cooling System
Efficiency
Unit Control
Advanced
Performance,
Diagnostics and
Efficiency
21
Containment Comparison
<<Without containment
With containment>>
22
Smart Aisle Overview
• Smart Aisle is a control mode that allows iCOM to manage air flow
and cooling capacity independently.
• Smart Aisle is a server centric solution meaning that it focuses on the
inlet temperature to the servers
• As the environment changes due to server utilization, equipment
location changes and outside variables so does the iCOM controller
• Adapts from no containment to end containment to full containment
23
Cold Aisle Containment - SmartAisle™
Integrated Containment Benefits
Control with iCOM
Match Cooling and Airflow to IT
equipment delta T to eliminate waste
iCOM will vary the fan speed independently with Liebert DS and Liebert CW to
match server ΔT to eliminate bypass air
Other benefits
Higher rack density ~ 12kW
Recover stranded cooling capacity
Less dependant on open floor tile placement
24