Cooling Solutions for the IT environment “APC has the complete cooling solutions line for your data center needs. We offer a range of products to meet all density levels for wiring closets, small, medium, and large data centers. Our highly efficient, scaleable solutions with active response controls offer predictable cooling for your needs today and in the future.” Donna Williams Director, Product Line Management, Cooling Solutions Modular/High-Density Air Conditioning 4 Air Distribution/Fans 9 Room Air Conditioning 13 Wiring Closet Ventilation Unit NetworkAIR FM Rack Air Removal Unit SX NetworkAIR PA InfraStruXure Cooling Distribution Unit Rack Air Distribution Unit Heat Rejection 15 InfraStruXure® InRow™ RP Rack Side Air Distribution Unit Chillers InfraStruXure® InRow™ RC ® InfraStruXure® InRow™ SC Hot Aisle Containment System Rack Air Containment System System-level solutions for data centers on demand InfraStruXure, APC’s innovative methodology for designing, deploying and optimizing data centers, fully integrates power, cooling, security, and environmental management within a rack-optimized design. Using an open, building-block approach, InfraStruXure allows the selection of standardized components to create a solution through modular configurations. This standardization enables an easily scalable architecture designed to meet changing needs and future expansion. This award-winning, patent-pending approach increases availability, improves adaptability, speeds deployment, and lowers the total cost of ownership for IT environments—from wiring closets to server rooms to data centers. The support structure of all highly available networks consists of power, cooling, racks and physical structure, security and fire protection, cabling, and the management and servicing of these elements. For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268 30 kW & above Ensuring the proper environment for IT systems is essen- APC cooling solutions give you the maximum amount tial to maintaining high availability. Regardless of applica- of cooling in the least amount of floor space. Scalable tion, IT equipment produces heat that can be damaging to solutions, including air distribution/fans, portables, and both uptime and the longevity of your investment. precision cooling systems, are tailored to meet the unique Designed to provide cool air distribution and heat remov- cooling demands of your environment, from wiring clos- al in any IT environment at the rack, row, and room level, ets and computer rooms to data centers of all sizes. Heat Density (per rack) Server Room / Wiring Closet Solutions Product / Applications Data Center Solutions Product / Applications Rack Air Containment High Density Racks Best predictability 23 kW Hot Aisle Containment System High Density Zones Best capacity sharing Best predictability Best floor space utilization Improved redundancy and efficiency 10 kW InRow™ RC & CDU, RP Medium to high density modular and scalable 7 kW InRow SC In-row air conditioning for server rooms and wiring closets Air Removal Unit Hot spot problem solver NetworkAIR PA Portable, self-contained air conditioning NetworkAIR FM Low density Very flexible 4 kW 3 kW Wiring Closet Ventilation Unit Rapidly deployable wall and ceiling mount heat removal For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268 Air Distribution Unit Raised floor air distribution Side Air Distribution Unit Side to side air distribution Modular/High Density Air Conditioning InfraStruXure® InRow™ RC In-row air conditioning for medium to large data centers including high density applications. Data center heat densities continue to increase, making it more difficult to provide adequate cooling. To ensure proper airflow paths the distance between the heat source and heat removal system must decrease. The in-row concept closely couples cooling with heat load, preventing exhaust air recirculation to sensitive IT equipment. The InfraStruXure InRow RC is a computer room air conditioning system designed for installation in the row to maximize sensible cooling and increase efficiency. The unit captures heat directly from the hot aisle and distributes cool air ensuring that equipment temperatures are constantly held to setpoint conditions. The energy-efficient design lowers total cost of ownership by monitoring IT equipment inlet temperatures to modulate capacity based on the demand for cooling. Fan speed is controlled based on the demand to reduce energy consumption during off-peak cooling periods. Heat rejection ACRC100 for the unit can be handled through an existing chilled water system ACRC103 or an APC-supplied chiller. The modular, scalable solution improves Cooling Option Chilled Water agility by enabling you to add cooling as demand increases, making Capacity up to 30 kW the InRow RC ideal for small to large datacenters. Airflow 2900 CFM Nominal Input Voltage 100V,120V 200V Features and Benefits Input Power 1100 Watts Availability Rack Height • Active response controls Monitor and actively adjust cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided. Input Connections NEMA L5-20P Control panel Multi-function LCD status and control console 1380 Watts Input Frequency • Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. IEC 309 16A 2P+E 78.39 in (1991.00 mm) Maximum Width 11.81 in (300.00 mm) Maximum depth 42.126 in (1070.00 mm) • Dual A-B power inputs Draws power from the UPS for power protection with dual feeds for redundancy. • Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor. Units per Pallet • Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods. 42U Maximum Height Net Weight Total Cost of Ownership 50/60 Hz Color Regulatory Approvals Standard Warranty 358 lbs. (162.73 kg) Black 1 cUL Listed,FCC Part 15 Class A,ICES-003,Industry Canada,MEA,UL Listed,VCCI C-tick,CE,EN 55022 Class A,EN 55024,EN 60950,IEC 60950,IEC 61000-3-2,IEC 61000-3-3,MEA,VDE 1 year (parts only) • In-Row architecture In-row architecture enables pay-as-you-grow deployment of cooling. Manageability • Microprocessor controller Utilizes intelligent, proactive control and real-time capacity monitoring. The system is controlled by a master microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display. • Building management system integration Sends alarms and data points allowing you to manage critical building infrastructure from a single system. Agility • Modular design Provides scalable solutions to add cooling as demand increases. Serviceability • Hot swappable fans Allow system to remain operational if a fan replacement is required. • Infrastruxure manager compatible Enables centralized management via the APC InfraStruXure® Manager. For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268 Modular/High Density Air Conditioning InfraStruXure® Cooling Distribution Unit Flexible chilled water distribution system for the InfraStruXure® InRow™ RC. The Cooling Distribution Unit provides centralized cooling, balancing and distribution through jointless and flexible chilled water piping in the data center. The Cooling Distribution Unit and Chilled Water Whip system allows for quick deployment and enables customer infrastructure the flexibility to grow and change with minimal labor and installation costs. PEX-AL-PEX piping, used for chilled water piping between the CDU and InRow RC, allows the chilled water to be routed without the use of elbows or any intermediate joints from the CDU to each InRow RC. This application greatly improves the reliability of the system by dramatically reducing the chance of leakage. PEX-AL-PEX is a multi-layered composite tubing consisting of aluminum tubing sandwiched between inner and outer layers of cross-linked polyethylene, providing flexibility of the piping to be routed through the data center with the rigidity to stay in place. With smooth interior walls and the chemical properties of the material, PEX-AL-PEX is resistant to mineral buildup, corrosion, and the risk of pinholes. The multi-press fittings provide a reliable and leak resistant connection to both the CDU and InRow RC. ACFD12-CXX-T Cooling Options ACFD12-CXX-B Glycol, Chilled Water The individual chilled water lines to the RC are both flexible and Capacity up to 12 InRow RC units jointless, enabling customer infrastructure to be deployed quickly, Maximum Height 78.40 inches (1991 mm) added for future expansion, or rerouted with minimal time as Maximum Width 42.13 inches (1070 mm) demands change. Maximum depth 29.53 inches (750 mm) Net Weight Features and Benefits Color Agility Regulatory Approvals • Flexible piping Flexible piping allows for quick deployment and start up. Standard Warranty Units per Pallet 500 lbs. (227.27 kg) Black 1 cUL Listed,MEA,UL Listed 1 year (parts only) Availability • Jointless piping Jointless piping minimizes the risk of fluid leaks. Serviceability • Coolant isolation Allows isolation of cooling circuits for servicing. For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268 Modular/High Density Air Conditioning InfraStruXure® InRow™ RP In-row precision air conditioning for medium to large data centers including high density applications. InfraStruXure InRow RP is a high capacity precision air conditioning unit designed to maximize sensible cooling for high efficiency operation. The InRow RP product increases the capacity range for chilled water applications and includes an air cooled solution. Both the chilled water and air cooled products offer the ability to control humidity with canister humidifiers and electric reheat, enabling data center designs to leverage the InRow Architecture for both sensible cooling of the IT load in the row, and humidity control of the entire data center. The in-row concept closely couples cooling with the heat load, preventing exhaust air recirculation to sensitive IT equipment. The energy-efficient design lowers total cost of ownership by monitoring IT equipment inlet temperatures to modulate capacity based on the demand for cooling. Fan speed is controlled based on the demand to reduce energy consumption during off-peak cooling periods. The modular, scalable solution improves agility by enabling you to add cooling as demand increases, making the InRow RP ideal for small to large data centers. Total Cost of Ownership Features and Benefits • Variable speed fans Reduce energy consumption during off-peak cooling periods. • In-Row architecture Enables pay-as-you-grow deployment of cooling. Availability Agility • Active response controls Monitor and actively adjust cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided. • Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. • Rack inlet control Guarantees inlet temperature to IT equipment. • Steam humidifier Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure-steam canister maintains consistent capacity output, and requires very little scheduled maintenance. • Real-Time capacity monitoring Real-time display of current and available cooling. • Electric reheat Prevents overcooling during dehumidification • Modular design Provides scalable solutions to add cooling as demand increases. ACRP100 Cooling Options Capacity Airflow Nominal Inout Voltage Input Power Input Frequency Input Connections Warranty ACRP101 Serviceability • Field replaceable components Fans and electronics module can be readily replaced without uninstalling the unit. Manageability • Microprocessor controller An 80-character LCD backlit alphanumeric display provides communication and alarm indication. ACRP102 ACRP500 ACRP501 R407C Chilled Water 10–37 kW up to 70 kW 4800 ACRP502 6950 200–240 3PH 460–480 3PH 380–415 3PH 200–240 3PH 460–480 3PH 380–415 3PH 13737W 11212W 13056W 3204W 2054W 2818W 50/60 60 50 50/60 60 50 Hardwire 4-wire (3PH+G) 1 year parts only For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268 Modular/High Density Air Conditioning InfraStruXure® InRow™ SC Rapidly deployable, in-row air conditioning for server rooms and wiring closets. New technologies are increasing heat loads in today’s server rooms and wiring closets, which often lack adequate cooling. The APC InfraStruXure InRow SC is a self-contained cooling solution that maximizes availability within small IT rooms. This energy-efficient unit lowers operating costs by using variable speed fans, capacity modulation, and an in-row form factor. The InRow SC’s plug-andplay design allows for rapid installation without the need for running refrigerant lines or providing remote heat exchangers. The predictive failure notification and high head pressure protection features, along with hot-swappable fans, improve the availability of IT equipment. Features and Benefits Agility • Easy to install Self-contained design allows for fast installation without refrigerant lines or remote heat exchangers. Unit requires only power, condensate drain and an available return plenum to provide effective cooling. • In-Row architecture Provides increased predictability of cooling performance. • Modular design Provides scalable solutions to add cooling as demand increases. Manageability ACSC100 ACSC101 Cooling Option R410A Capacity up to 7 kW Compressor Type Rotary Air Discharge Patterns Horizontal Intake Air Rear Return Refrigerant R410A Air Flow 1200 CFM Nominal Input Voltage Input Power 200V, 208V, 230V 2940 Watts 2530 Watts 60 Hz +/- 3 Hz 50 Hz +/- 3 Hz IEC 309 16A 2P+E • Real-Time capacity monitoring Displays current and available cooling. Input Frequency • Microprocessor controller Displays an 80-character LCD backlit alphanumeric display that provides communication and alarm indication. Input Connections NEMA L6–20P Control panel Multi-function LCD status and control console • Network manageable View the user interface with a browser. Gives quick access from anywhere on the network Maximum Height Maximum Width 300.00 mm • InfraStruXure Manager compatible Enables centralized management via the APC InfraStruXure Manager. Maximum depth 1069.00 mm • Building management system integration Allows you to send alarms and data points to manage critical building infrastructure from a single system. Color Availability • Ducted condenser air Uses unconditioned air from plenum space to reject the heat rather than conditioned room air. 1991.00 mm Net Weight Regulatory Approvals 165.91 kg Black BSMI,EN 55022 Class A,FCC Part 15 Class A,ICES-003,UL Listed,VCCI,VDE, CCC Standard Warranty BSMI, EN 55022 Class A, FCC Part 15 Class A, ICES-003,UL Listed, VDE, VCCI C-tick, CE, CCC 1 year repair or replace • Built-In condensate pump Factory installed pump collects and removes water from the air conditioner, ensuring continuous operation. Serviceability • High head pressure protection Ensures the InRow SC remains operational even when the condenser inlet air is restricted or very hot. • Hot swappable fans Allow system to remain operational if a fan replacement is required. • Coil freeze protection Hot gas bypass prevents evaporator coil from freezing during light load conditions. • Washable filters Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream. • Predictive failure notification Maximizes system availability by providing early warning of required fan or filter replacement. Total Cost of Ownership • Automatic restart In the event of a power failure the InRow™ SC will resume operation. • Rack inlet temperature control Reduces the risk of hot spots at the rack level. • Variable speed fans Reduce energy consumption during off-peak cooling periods. • Green refrigerant Environmentally friendly refrigerant that can offer LEED points. For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268 Modular/High Density Air Conditioning Hot Aisle Containment Hot aisle containment for high-density configurations. Mixing of hot and cold air streams in the data center lowers availability of IT equipment. Returning the warmest possible air to the computer room air conditioners increases the efficiency and capacity of the system. The hot aisle containment system ensures proper air distribution by completely separating supply and return air paths. The hot aisle is sealed off using doors and transparent ceiling tiles that extend the width of the hot aisle. Ceiling tiles are available for both 19” and 23” racks. Two-rack kits complete with ceiling tile and hardware are available for future expansion. • One-way locking door Secures the hot aisle while allowing for quick exit in case of emergency. Features and Benefits • Scaleable densities Allow higher density cooling to be achieved by integrating the hot aisle containment system with in-row architecture. Availability • Modular design Modular design provides scalable solutions to add cooling as demand increases. • Cable access brush strip Blocks air from escaping through holes surrounding cabling. Total Cost of Ownership Agility • Ceiling tiles Close off the top of the hot aisle to prevent warm air from mixing with room air. • Energy efficiency Increases cooling capacity of the associated air conditioners without driving up power consumption. Rack Air Containment Modular air containment system designed to maximize cooling predictability, capacity, and efficiency. Deployment of high density loads in IT environments can create areas of unpredictable cooling performance. APC’s Rack Air Containment is a modular system designed to work in conjunction with APC NetShelter® SX enclosures and InRow™ cooling units to provide maximum cooling predictability, capacity, and efficiency. By attaching to the rear of the NetShelter SX, air exhausted from IT equipment is forced to pass through the cooling unit where it is conditioned. This ensures that warm exhaust air does not find its way back to the air inlets of installed servers. N+1 and 2N configurations allow for maximum availability. Front containment can also be added to Availability provide additional isolation and noise dampening. • Redundancy Systems can be configured to included an additional InRow cooling unit to provide N+1 or 2N redundancy. Features and Benefits • Integrated pressure sensors Pressure sensors in the InRow cooling units provide fan speed control for optimum system efficiency. Adaptability Convenience • Modular design Compatible with standard NetShelter SX racks, providing maximum system flexibility and scalability. • Noise dampening Containment of both front and rear provides reduction of noise caused by installed equipment. • Front containment Ensures cold supply air is not captured by neighboring equipment. • Plexiglass door inserts Provides required air containment and a consistent look across the racks while allowing visibility to installed IT equipment. • Rear containment Ensures server exhaust air is returned to the InRow cooling units for maximum cooling predictability. • Easy to install Innovative design allows for fast, easy installation by almost anybody. For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268 Air Distribution/Fans Wiring Closet Ventilation Unit Rapidly deployable wall and ceiling mount heat removal for wiring closets. Wiring closet heat loads are rising due to deployment of technologies such as VoIP and Power over Ethernet. The Wiring Closet Ventilation Unit is a rapidly deployable wall and ceiling mount heat removal system designed specifically for the wiring closet environment. By exhausting hot air from the closet to an adjacent space it allows conditioned air (entering through the Air Intake Grill) to cool the load. Dual fans increase availability while LED status indicators and dry contact outputs enhance the unit’s manageability. Selectable fan speeds allow the user to choose between maximum performance and quiet operation. Features and Benefits Availability Manageability • Fault-tolerant fan system In event of a fan failure the remaining fan automatically speeds up to compensate. Fans are N+1 redundant up to 300 CFM of airflow. • Predictive failure notification Maximizes system availability by providing early warning of required fan replacement. • Selectable speed fans Selectable fan speed (high/low) via toggle switch provides options for maximum performance or quiet operation. • Dry contact output Provides remote notification of failures when used with APC environmental monitoring unit or system. • LED status indicators Provide visual notification of fan failure. Adaptability • Multiple mounting methods Flexible design allows for both drywall and ceiling mount installations. • Easy to install Innovative design allows for fast, easy installation by almost anybody. ACF301 Cooling Capacity Options • Hardwire capable For installations where hard wiring is required or prefered. Air Flow • Architecturally neutral Unobstrusive design and coloring blends in with the surroundings. Input Power Nominal Input Voltage Input Connections 3 kW of heat removal 475.00 CFM 100–240V, 50/60 Hz 85 Watts Input Hard Wire 3-wire, IEC-320 C14, NEMA 5-15P Maximum Height 12.80 inches (325 mm) Maximum Width 17.10 inches (434 mm) Maximum depth 7.00 inches (178 mm) Color Regulatory Approvals Standard Warranty For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268 White cUL Listed,CE,EN 55022 Class A,EN 55024, FCC Part 15 Class A,VCCI 2 years repair or replace Air Distribution/Fans Rack Air Removal Unit SX Performance heat removal for high-density equipment in NetShelter® SX and VX enclosures. High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, ducting it to the return air plenum and eliminating hot spots. Through automatic fan speed adjustment based on temperature or power consumption, the fans will self-adjust for optimal performance. With a unit-mounted LCD display users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control of the Rack Air Removal Unit SX. This space-saving product mounts to the back of either the NetShelter SX or VX enclosure – requiring zero U space. Features and Benefits Manageability • Network manageable View the user interface with a browser. Gives quick access from anywhere on the network ACF400 Cooling Capacity Options • InfraStruXure® Manager compatible Enables centralized management via the APC InfraStruXure Manager. Air Discharge Patterns • Temperature monitoring Allows up to 3 remote sensors to monitor rack inlet temperature. Nominal Input Voltage 23 kW Upflow,Ducted Air Flow • LCD display Accessible without opening the door for easy operation. Allows user to locally monitor and control the unit. Input Power Availability Input Connections • Fault-tolerant fan system In event of a fan failure the remaining fans will speed up to compensate. Fans are N+1 redundant up to 1500 CFM of airflow. Control panel • Dual A-B power inputs Draw power from the UPS for power protection with dual feeds for redundancy. Maximum Width 2000 CFM 1200 Watts • Field replaceable components Fans and electronics module can be readily replaced without uninstalling the unit. Adaptability 50/60 Hz IEC-320 C14, NEMA 5–15P Multi-function LCD status and control console Maximum Height 1918.00 mm 597.00 mm Maximum depth Net Weight Color Regulatory Approvals Standard Warranty Upflow,Ducted 100V,120V,200V,208V,230V Input Frequency • Ducted Exhaust System Removes hot air from the data center to prevent recirculation and eliminate air mixing. ACF402 737.00 mm 254 mm 67.27 KG 77.27 KG Black cUL Listed,CE,EN 55022 Class A,EN 55024,FCC Part 15 Class A,ICES-003,IEC 61000-3-2,IEC 61000‑3‑3,UL Listed,VDE,VCCI 2 years repair or replace • Adjustable mounting frame The frame can mount on Netshelter SX or VX enclosures and extends to accommodate 42U, 47U or 48U rack heights. • Zero “U” Solution Mounts to the rear of the rack, leaving valuable rack space for other equipment. Total Cost of Ownership • Easy to install Innovative design allows for fast, easy installation by almost anybody. • Variable speed fans Reduce energy consumption during off-peak cooling periods. • Increased capacity Higher rate of heat removal allows more equipment to be installed in each rack. 10 For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268 Air Distribution/Fans Rack Air Distribution Unit Air distribution for power dense enclosures and low pressure areas The Rack Air Distribution Unit is a 2U fan unit that works with an existing precision air conditioning system to deliver cool air to the equipment contained in a rack enclosure. The Rack Air Distribution Unit connects into the raised floor and pulls supply air directly into the enclosure. This prevents the conditioned air from mixing with warmer room air before reaching the equipment. The Rack Air Distribution Unit minimizes temperature differences between the top and bottom of the enclosure. It also prevents hot exhaust air from recirculating to the inlet of the enclosure. The product is recommended for rack enclosures with loads greater than 1.5kW and can provide airflow for loads up to 3.5kW. It is also ideal for enclosures in raised floor environments where underfloor air distribution is inadequate. Air Flow Amp Draw Nominal Nominal Input Voltage Input Power Input Frequency Features and Benefits: Availability ACF001 ACF002 ACF003 503 CFM 420 CFM 503 CFM 2A 1A 2A 120V 208V, 230V 100V 240 Watts 230 Watts 200 Watts 60 Hz +/- 1Hz 50/60 Hz 50/60 Hz C-13 NEMA 5–15P C-13 IEC-320 C14 Rack Height Input Connections 2U • Dual fans Deliver air to equipment in the rack where floor tile velocity is inadequate for proper cooling. Maximum Height • Raised floor duct Delivers cool, conditioned air directly from the raised floor to the inlet of the IT equipment. Maximum depth 737 mm Agility Net Weight 18.64 KG Color • Air filtration Removes dirt and other particulates from the intake air for cleaner supply air. • Fan control switches Users can turn one or both fans on and off depending on the heat load. Maximum Width Regulatory Approvals Standard Warranty C-13 NEMA 5–15P 89.00 mm 422.00 mm 421.00 mm Black UL Recognized CE, UL Recognized METI Denan, UL Recognized 2 years repair or replace • Mounting rails Adjustable depth allows the unit to fit APC's NetShelter® enclosure or other 19" EIA-310-D enclosure. • Fan guards A safety measure that provides protection from the fan opening by covering the inlet. Total Cost of Ownership • Dual A-B power inputs Draw power from the UPS for power protection with dual feeds for redundancy. For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268 11 Air Distribution/Fans Rack Side Air Distribution Unit Air distribution for networking equipment with side to side airflow Housing equipment with side to side airflow creates many challenges for IT and facility managers, particularly in regards to cooling. Because most enclosures are designed for a front to back airflow pattern, it is difficult to maintain ideal operating temperatures on side to side airflow equipment. The Rack Side Air Distribution Unit allows for greater security and organization by allowing racks to be placed adjacent to one another without impeding airflow. The Rack Side Air Distribution Unit is a 2U rack mountable air distribution product for networking equipment or servers with Nominal Input Voltage side to side airflow. It pulls in conditioned air from the front of Input Power the rack and distributes it to the side air intake of the networking Input Frequency equipment. This extends equipment life by providing proper inlet temperatures. ACF201BLK ACF202BLK 120V 208V, 230V 150 Watts 60Hz 50/60Hz Air Flow Amp Draw Nominal 260 CFM 2A 1A Net Weight 32 lbs (15kg) This product is recommended for one or more networking products Max. Height 3.44 inches (87.4 mm) that are stacked consecutively in a rack. Rack Side Air Distribution Max. Width 16.98 inches (431 mm) Units may be placed above and/or below the networking equip- Max. Depth 26.34 inches (669 mm) ment. Airflow pattern is user configurable via an interchangeable Color Approvals air turning vane. Standard warranty Black UL Recognized CE 2 years repair or replace Features and Benefits: Availability • Dual fans Deliver air to equipment in the rack where floor tile velocity is inadequate for proper cooling. • Fan control switches Users can turn one or both fans on and off depending on the heat load. Agility • Mounting rails Adjustable depth allows the unit to fit APC's NetShelter® enclosure or other 19" EIA-310-D enclosure. • Fan guard A safety measure that provides protection from the fan opening by covering the inlet. Total Cost of Ownership • Dual A-B power inputs Draw power from the UPS for power protection with dual feeds for redundancy. • Air turning vane Directs air up or down the side of the rack, supplying cool air to the inlet of side to side airflow equipment. Manageability • LED status indicators Indicate the operating condition of the unit including power-on and alarm state. 12 For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268 Room Air Conditioning NetworkAIR® FM Modular floor mount precision air conditioning for environmentally sensitive equipment areas The NetworkAIR FM utilizes leading edge precision air technologies. Modular construction, variable frequency drives, dedicated dehumidification, tandem scroll compressors, and front service access are all integrated into one high efficiency system. A scalable design enables customers to meet the changing needs of their environments. Features and Benefits Availability • Tandem scroll compressors Quiet and efficient operation of scroll compressors, connected on a common circuit for staged capacity control (N/A chilled water systems). • Direct drive motors Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced which lowers vibration and expedites startup. Eliminates the need for unreliable belts, pulleys and special bearings. • Variable frequency drives Enable the fans to be soft started, saving energy during power up. Controlling the motor speed simplifies the adjustment for static pressure and gives the option of back-draft prevention. Economy • Dedicated dehumidification Boosts system efficiency by adding latent capacity without overcooling or increasing the requirement for reheat, resulting in up to 15% lower energy consumption (N/A chilled water systems). • SCR electric reheat Modulates capacity to save energy. Exacting amounts of reheat loaded equally on all three phases. • Steam humidifier Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure-steam canister maintains consistent capacity output, and requires very little scheduled maintenance. Manageability Serviceability • Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character alphanumeric display. • Programmable input/output contacts Allows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms. • Front service access The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side. Protection • Network interface Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur. • Double-walled panels Separates insulation from the air stream, which prevents periodic maintenance of the insulation and reduces noise levels. Small particles of insulation can be picked up by the air stream if not isolated. • Redundant group control Allows up to 4 groups of precision air conditioners to communicate with each other for redundancy, demand fighting prevention, mode assist, and global sharing of certain settings. FM-DX 60Hz Cooling Options FM-CW 60Hz Air, Water, Glycol, Economizer, Multicool Humidification Capacity Compressor Type / Refrigerant FM40H-AGB-ESD Chilled Water 10 lbs/hr Chilled Water 10 lbs/hr Tandem Scroll / R22 Input Frequency FM40B-CFB-ESD Air N/A Tandem Scroll / R407C N/A 60 Hz 50 Hz Nominal Input Voltage 208V 3PH, 480V 3PH, 600V 3PH 400V 3PH Air Discharge Patterns Downflow, Upflow Front Return, Upflow Rear Return Control Panel Net Weight Downflow Microprocessor Controller 2,360 lbs (1072.73 kg) 1,180 lbs (536 kg) 2,360 lbs (1072.73 kg) Max. Height 76.89 inches(1953.01 mm) Max. Width 70.87 inches (1800.1 mm) Max. Depth 35.00 inches (889.00 mm) Approvals Standard Warranty CSA, MEA, UL Listed 1,180 lbs (536 kg) CE, Eurovent 1 year (parts only) optional extended warranties available. For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268 13 Room Air Conditioning NetworkAIR® PA* Portable, self-contained air conditioning solutions for small rooms and data closets Inconsistent and high temperatures can lower the expected life of, and permanently damage your electronic equipment. IT refreshes and equipment relocation result in unpredictable and ever-changing environments. The NetworkAIR PA provides portable cooling for your sensitive electronic equipment to meet the environmental demands of small rooms and data closets. This self-contained solution does not require an external condenser, refrigerant piping, or building water source for operation. Heat is rejected to a drop ceiling or adjacent area via a flexible duct kit. The NetworkAIR PA can be installed quickly and inexpensively, without the need for building modifications. Features and Benefits: Availability • Automatic restart Returns the unit to its last operating status in the event of a power failure, in order to protect the compressor and the environment. (Not available on the AP7003 unit). • Ducting kit Allows hot air to be removed and distributed to a drop ceiling or hard-ducted return. This increases the efficiency of the computer room air conditioning system in both capacity and dehumidification. ACPA4000 Cooling Capacity 3.9kW Air Compressor Type Rotary Nominal Input Voltage Input Power Input Frequency Agility Air Flow 120V 1,610 Watts 692 Watts 60Hz Coolant • Replacement ceiling tile Fits into a standard drop ceiling to provide a connection point for the ducting kit. (Not available on the AP7003 unit). 1.6kW Cooling Options • High head pressure protection Prevents compressor damage (not available on AP7003 unit). • Easy to install Self-contained, air cooled design allows for fast, easy installation. AP7003 R22 600 CFM 170 CFM Condensate Tank N/A 3.5 qt Condensate Pump 1.6 gal/hr Approvals Standard Warranty N/A UL Listed 1 year repair or replace • Casters Provide flexibility to move the unit to wherever cooling is required. Manageability • Network manageable Remotely monitor and control NetworkAIR PA4000 environmental information from anywhere on the network via a Web browser (not available on the AP7003 unit). • LED status indicators Four (4) external status indicator LEDs represent: major alarm; minor alarm; check log (new alarm/warning has occurred); system on (evaporator blower is running). Not available on the AP7003 unit. • On/off scheduling Allows the user to determine when the unit operates, saving energy costs. (Not available on the AP7003 unit). * available in North America only 14 For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268 Heat Rejection Air Cooled Modular Chillers* Air Cooled Chillers for air conditioning equipment in data centers, server rooms and wiring closets. APC air cooled chillers for air conditioning equipment in data centers are a new generation of leading-edge technology. These all-in-one integrated packages reduce time and cost of installation. Features and Benefits: Manageability • Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display. • ModBus translator Optional feature allows integration with Building Management System. Total Cost of Ownership • Variable speed fans Reduce energy consumption during off-peak cooling periods. • Integrated hydronics package Includes all the necessary components to make one connection to the chilller without the need of external connections to auxiliary equipment such as pumps, increasing the speed of deployment. Availability • Scroll compressors Utilize few moving parts for increased reliability and life expectancy. • Independent power feed Optional feed to the pumps allows for wiring to the UPS, thus ensuring chilled water availability during generator start-up when used with a storage tank. • Dual redundant pumps Provide reliable chilled water flow sized for full capacity. • Low ambient controls Enable chiller operation in temperatures down to -20°F. Convenience • Optional storage tank Fits under chiller without increasing footprint. SKU Series Capacity UPSable pump (optional) Storage tank option Windbaffle option Voltages ACCH050 ACCH084 ACCH120 ACCH167 ACCH200 ACCH220 50kW 84KW 120KW 167KW 200KW 220KW Yes Yes Yes Yes N/A N/A ACTA1100 ACTA1101 ACTA1102 ACTA1102 N/A N/A ACAC30001 ACAC30002 ACAC30003 ACAC30004 ACAC30005 ACAC30005 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH Height in inches* 52 52 52 52 90 90 Width in inches* 82 108 108 108 95 95 Depth in inches* Weight in lbs* 43 43 90 90 89 89 1298 1819 3134 3603 4705 4911 Standard Warranty 1 year (parts only), optional extended warranties available * Weights and dimensions do not include storage tank or windbaffles * available in North America only For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268 15 S ince 1981, APC has been a global leader in power availability solutions, setting the industry standard for quality, innovation, and support. From its corporate headquarters in West Kingston, Rhode Island, APC operates sales offices throughout the world and manufacturing facilities on four continents and distribution facilities on five continents. APC ships products to over 150 countries. Over 30 million satisfied customers worldwide depend on APC’s Legendary Reliability®. Propelled by real-world experience and a drive towards technological innovation, APC has the experience, scale, global presence, and stability to respond to emerging IT availability needs. As the recipient of hundreds of awards worldwide, APC is recognized for excellence in both its business and product performance. Every year since 1999, APC has been named to the Forbes Platinum 400 list of the Best Big Companies in America. For 11 years in a row, APC has received the Channel Champion award in the UPS category. es Strategi Cooling igh -h for Ultra cks and ra density ers rv blade se Choose the optimal service solution to increase your system availability. Receive your FREE APC white paper “Cooling Strategies for Ultra-High Density Racks and Blade Servers”. Visit us online at http://promo.apc.com and enter key code s369y. APC’s quality system is certified by ISO 9002 standards For more information call: Tel: 800 800 4APC - US & Canada Tel: 401 789 0204 - World wide APC Corporate APC North America 132 Fairgrounds Road West Kingston, RI 02892 USA Call: 800 800 4APC Fax: 401 789 3710 APC Latin America 5301 Blue Lagoon Drive Suite #610 Miami, FL 33126 USA Call: 305 266 5005 Fax: 305 266 9695 APC Europe APC Ireland Ballybrit Business Park Galway, Ireland Call: +353 91 702000 Fax: +353 91 756909 APC Asia Pacific APC Australia Level 13 The Denison 65 Berry Street North Sydney, NSW 2060 Call: +61 2 9955 9366 Fax: +61 2 9955 2844 Visit: www.apc.com e-mail: apcinfo@apc.com Web Support: : support. apc.com ©2007. All rights reserved. All APC trademarks are property of American Power Conversion. Other trademarks are property of their respective owners. Specifications are subject to change without notice. PART# 996-2854B