Cooling Solutions

advertisement
Cooling Solutions
for the IT environment
“APC has the complete cooling solutions line for your data center
needs. We offer a range of products to meet all density levels for
wiring closets, small, medium, and large data centers. Our highly
efficient, scaleable solutions with active response controls offer predictable cooling for your needs today and in the future.”
Donna Williams
Director, Product Line Management, Cooling Solutions
Modular/High-Density
Air Conditioning 4
Air Distribution/Fans 9
Room Air Conditioning 13
Wiring Closet Ventilation Unit NetworkAIR FM
Rack Air Removal Unit SX
NetworkAIR PA
InfraStruXure Cooling Distribution
Unit
Rack Air Distribution Unit
Heat Rejection 15
InfraStruXure® InRow™ RP
Rack Side Air Distribution Unit
Chillers
InfraStruXure® InRow™ RC
®
InfraStruXure® InRow™ SC
Hot Aisle Containment System
Rack Air Containment System
System-level solutions for
data centers on demand
InfraStruXure, APC’s innovative methodology for designing, deploying and optimizing data centers, fully integrates power, cooling,
security, and environmental management within a rack-optimized
design. Using an open, building-block approach, InfraStruXure
allows the selection of standardized components to create a solution through modular configurations. This standardization enables
an easily scalable architecture designed to meet changing needs
and future expansion. This award-winning, patent-pending approach
increases availability, improves adaptability, speeds deployment,
and lowers the total cost of ownership for IT environments—from
wiring closets to server rooms to data centers.
The support structure of all highly available networks
consists of power, cooling, racks and physical
structure, security and fire protection, cabling, and the
management and servicing of these elements.
For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
30 kW &
above
Ensuring the proper environment for IT systems is essen-
APC cooling solutions give you the maximum amount
tial to maintaining high availability. Regardless of applica-
of cooling in the least amount of floor space. Scalable
tion, IT equipment produces heat that can be damaging to
solutions, including air distribution/fans, portables, and
both uptime and the longevity of your investment.
precision cooling systems, are tailored to meet the unique
Designed to provide cool air distribution and heat remov-
cooling demands of your environment, from wiring clos-
al in any IT environment at the rack, row, and room level,
ets and computer rooms to data centers of all sizes.
Heat
Density
(per rack)
Server Room /
Wiring Closet
Solutions
Product / Applications
Data Center Solutions
Product / Applications
Rack Air Containment
High Density Racks
Best predictability
23 kW
Hot Aisle Containment System
High Density Zones
Best capacity sharing
Best predictability
Best floor space utilization
Improved redundancy and
efficiency
10 kW
InRow™ RC & CDU, RP
Medium to high density
modular and scalable
7 kW
InRow SC
In-row air conditioning for
server rooms and wiring
closets
Air Removal Unit
Hot spot problem solver
NetworkAIR PA
Portable, self-contained
air conditioning
NetworkAIR FM
Low density
Very flexible
4 kW
3 kW
Wiring Closet Ventilation Unit
Rapidly deployable wall and
ceiling mount heat removal
For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Air Distribution Unit
Raised floor air distribution
Side Air Distribution Unit
Side to side air distribution
Modular/High Density Air Conditioning
InfraStruXure® InRow™ RC
In-row air conditioning for medium to large data centers
including high density applications.
Data center heat densities continue to increase, making it more difficult to provide adequate cooling. To ensure proper airflow paths the
distance between the heat source and heat removal system must
decrease. The in-row concept closely couples cooling with heat load,
preventing exhaust air recirculation to sensitive IT equipment. The
InfraStruXure InRow RC is a computer room air conditioning system
designed for installation in the row to maximize sensible cooling
and increase efficiency. The unit captures heat directly from the hot
aisle and distributes cool air ensuring that equipment temperatures
are constantly held to setpoint conditions. The energy-efficient
design lowers total cost of ownership by monitoring IT equipment
inlet temperatures to modulate capacity based on the demand for
cooling. Fan speed is controlled based on the demand to reduce
energy consumption during off-peak cooling periods. Heat rejection
ACRC100
for the unit can be handled through an existing chilled water system
ACRC103
or an APC-supplied chiller. The modular, scalable solution improves
Cooling Option
Chilled Water
agility by enabling you to add cooling as demand increases, making
Capacity
up to 30 kW
the InRow RC ideal for small to large datacenters.
Airflow
2900 CFM
Nominal Input Voltage
100V,120V
200V
Features and Benefits
Input Power
1100 Watts
Availability
Rack Height
• Active response controls Monitor and actively adjust cooling capacity
to ensure proper server inlet temperatures. Through the microprocessor
controller, visibility into the operation and health of the unit is provided.
Input Connections
NEMA L5-20P
Control panel
Multi-function LCD status and control console
1380 Watts
Input Frequency
• Predictable cooling Placing the unit in the row of racks moves the source
of cooling closer to the heat load. This eliminates air mixing and provides a
predictable cooling architecture.
IEC 309 16A 2P+E
78.39 in (1991.00 mm)
Maximum Width
11.81 in (300.00 mm)
Maximum depth
42.126 in (1070.00 mm)
• Dual A-B power inputs Draws power from the UPS for power protection
with dual feeds for redundancy.
• Top and bottom chilled water connections Allows chilled water to be
connected from the top, if routing from overhead, or bottom, if on a raised floor.
Units per Pallet
• Variable speed fans Variable speed fans reduce energy consumption
during off-peak cooling periods.
42U
Maximum Height
Net Weight
Total Cost of Ownership
50/60 Hz
Color
Regulatory Approvals
Standard Warranty
358 lbs. (162.73 kg)
Black
1
cUL Listed,FCC Part 15
Class A,ICES-003,Industry
Canada,MEA,UL Listed,VCCI
C-tick,CE,EN 55022 Class
A,EN 55024,EN 60950,IEC
60950,IEC 61000-3-2,IEC
61000-3-3,MEA,VDE
1 year (parts only)
• In-Row architecture In-row architecture enables pay-as-you-grow
deployment of cooling.
Manageability
• Microprocessor controller Utilizes intelligent, proactive control and
real-time capacity monitoring. The system is controlled by a master
microprocessor providing high level control functionality and human interface
via a four line, eighty character, alphanumeric display.
• Building management system integration Sends alarms and data points
allowing you to manage critical building infrastructure from a single system.
Agility
• Modular design Provides scalable solutions to add cooling as demand
increases.
Serviceability
• Hot swappable fans Allow system to remain operational if a fan
replacement is required.
• Infrastruxure manager compatible Enables centralized management via
the APC InfraStruXure® Manager.
For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Modular/High Density Air Conditioning
InfraStruXure® Cooling Distribution Unit
Flexible chilled water distribution system for the
InfraStruXure® InRow™ RC.
The Cooling Distribution Unit provides centralized cooling, balancing and distribution through jointless and flexible chilled water
piping in the data center. The Cooling Distribution Unit and Chilled
Water Whip system allows for quick deployment and enables
customer infrastructure the flexibility to grow and change with
minimal labor and installation costs.
PEX-AL-PEX piping, used for chilled water piping between the
CDU and InRow RC, allows the chilled water to be routed without
the use of elbows or any intermediate joints from the CDU to each
InRow RC. This application greatly improves the reliability of the
system by dramatically reducing the chance of leakage.
PEX-AL-PEX is a multi-layered composite tubing consisting of
aluminum tubing sandwiched between inner and outer layers of
cross-linked polyethylene, providing flexibility of the piping to be
routed through the data center with the rigidity to stay in place.
With smooth interior walls and the chemical properties of the
material, PEX-AL-PEX is resistant to mineral buildup, corrosion,
and the risk of pinholes. The multi-press fittings provide a reliable
and leak resistant connection to both the CDU and InRow RC.
ACFD12-CXX-T
Cooling Options
ACFD12-CXX-B
Glycol, Chilled Water
The individual chilled water lines to the RC are both flexible and
Capacity
up to 12 InRow RC units
jointless, enabling customer infrastructure to be deployed quickly,
Maximum Height
78.40 inches (1991 mm)
added for future expansion, or rerouted with minimal time as
Maximum Width
42.13 inches (1070 mm)
demands change.
Maximum depth
29.53 inches (750 mm)
Net Weight
Features and Benefits
Color
Agility
Regulatory Approvals
• Flexible piping Flexible piping allows for quick deployment and start up.
Standard Warranty
Units per Pallet
500 lbs. (227.27 kg)
Black
1
cUL Listed,MEA,UL Listed
1 year (parts only)
Availability
• Jointless piping Jointless piping minimizes the risk of fluid leaks.
Serviceability
• Coolant isolation Allows isolation of cooling circuits for servicing.
For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
Modular/High Density Air Conditioning
InfraStruXure® InRow™ RP
In-row precision air conditioning for medium to large data
centers including high density applications.
InfraStruXure InRow RP is a high capacity precision air conditioning unit designed to maximize sensible cooling for high efficiency
operation. The InRow RP product increases the capacity range
for chilled water applications and includes an air cooled solution.
Both the chilled water and air cooled products offer the ability to
control humidity with canister humidifiers and electric reheat,
enabling data center designs to leverage the InRow Architecture
for both sensible cooling of the IT load in the row, and humidity
control of the entire data center. The in-row concept closely couples cooling with the heat load, preventing exhaust air recirculation to sensitive IT equipment. The energy-efficient design lowers
total cost of ownership by monitoring IT equipment inlet temperatures to modulate capacity based on the demand for cooling.
Fan speed is controlled based on the demand to reduce energy
consumption during off-peak cooling periods. The modular, scalable solution improves agility by enabling you to add cooling as
demand increases, making the InRow RP ideal for small to large
data centers.
Total Cost of Ownership
Features and Benefits
• Variable speed fans Reduce energy consumption during off-peak cooling
periods.
• In-Row architecture Enables pay-as-you-grow deployment of cooling.
Availability
Agility
• Active response controls Monitor and actively adjust cooling capacity
to ensure proper server inlet temperatures. Through the microprocessor
controller, visibility into the operation and health of the unit is provided.
• Predictable cooling Placing the unit in the row of racks moves the source
of cooling closer to the heat load. This eliminates air mixing and provides a
predictable cooling architecture.
• Rack inlet control Guarantees inlet temperature to IT equipment.
• Steam humidifier Humidity is managed through a self-contained steam
canister humidifier for maximum efficiency and ease of maintenance. The
pure-steam canister maintains consistent capacity output, and requires very
little scheduled maintenance.
• Real-Time capacity monitoring Real-time display of current and available cooling.
• Electric reheat Prevents overcooling during dehumidification
• Modular design Provides scalable solutions to add cooling as demand
increases.
ACRP100
Cooling Options
Capacity
Airflow
Nominal Inout Voltage
Input Power
Input Frequency
Input Connections
Warranty
ACRP101
Serviceability
• Field replaceable components Fans and electronics module can be
readily replaced without uninstalling the unit.
Manageability
• Microprocessor controller An 80-character LCD backlit alphanumeric
display provides communication and alarm indication.
ACRP102
ACRP500
ACRP501
R407C
Chilled Water
10–37 kW
up to 70 kW
4800
ACRP502
6950
200–240 3PH
460–480 3PH
380–415 3PH
200–240 3PH
460–480 3PH
380–415 3PH
13737W
11212W
13056W
3204W
2054W
2818W
50/60
60
50
50/60
60
50
Hardwire 4-wire (3PH+G)
1 year parts only
For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Modular/High Density Air Conditioning
InfraStruXure® InRow™ SC
Rapidly deployable, in-row air conditioning for server rooms
and wiring closets.
New technologies are increasing heat loads in today’s server rooms
and wiring closets, which often lack adequate cooling. The APC
InfraStruXure InRow SC is a self-contained cooling solution that
maximizes availability within small IT rooms. This energy-efficient
unit lowers operating costs by using variable speed fans, capacity
modulation, and an in-row form factor. The InRow SC’s plug-andplay design allows for rapid installation without the need for running
refrigerant lines or providing remote heat exchangers. The predictive
failure notification and high head pressure protection features, along
with hot-swappable fans, improve the availability of IT equipment.
Features and Benefits
Agility
• Easy to install Self-contained design allows for fast installation without
refrigerant lines or remote heat exchangers. Unit requires only power,
condensate drain and an available return plenum to provide effective cooling.
• In-Row architecture Provides increased predictability of cooling
performance.
• Modular design Provides scalable solutions to add cooling as demand
increases.
Manageability
ACSC100
ACSC101
Cooling Option
R410A
Capacity
up to 7 kW
Compressor Type
Rotary
Air Discharge Patterns
Horizontal
Intake Air
Rear Return
Refrigerant
R410A
Air Flow
1200 CFM
Nominal Input Voltage
Input Power
200V, 208V, 230V
2940 Watts
2530 Watts
60 Hz +/- 3 Hz
50 Hz +/- 3 Hz
IEC 309 16A 2P+E
• Real-Time capacity monitoring Displays current and available cooling.
Input Frequency
• Microprocessor controller Displays an 80-character LCD backlit
alphanumeric display that provides communication and alarm indication.
Input Connections
NEMA L6–20P
Control panel
Multi-function LCD status and control console
• Network manageable View the user interface with a browser. Gives quick
access from anywhere on the network
Maximum Height
Maximum Width
300.00 mm
• InfraStruXure Manager compatible Enables centralized management via
the APC InfraStruXure Manager.
Maximum depth
1069.00 mm
• Building management system integration Allows you to send alarms
and data points to manage critical building infrastructure from a single
system.
Color
Availability
• Ducted condenser air Uses unconditioned air from plenum space to reject
the heat rather than conditioned room air.
1991.00 mm
Net Weight
Regulatory Approvals
165.91 kg
Black
BSMI,EN 55022 Class A,FCC
Part 15 Class A,ICES-003,UL
Listed,VCCI,VDE, CCC
Standard Warranty
BSMI, EN 55022 Class A,
FCC Part 15 Class A,
ICES-003,UL Listed, VDE,
VCCI C-tick, CE, CCC
1 year repair or replace
• Built-In condensate pump Factory installed pump collects and removes
water from the air conditioner, ensuring continuous operation.
Serviceability
• High head pressure protection Ensures the InRow SC remains operational
even when the condenser inlet air is restricted or very hot.
• Hot swappable fans Allow system to remain operational if a fan
replacement is required.
• Coil freeze protection Hot gas bypass prevents evaporator coil from
freezing during light load conditions.
• Washable filters Easy to maintain, cleanable, deep loading mesh filter
removes particles from the return air stream.
• Predictive failure notification Maximizes system availability by providing
early warning of required fan or filter replacement.
Total Cost of Ownership
• Automatic restart In the event of a power failure the InRow™ SC will
resume operation.
• Rack inlet temperature control Reduces the risk of hot spots at the rack level.
• Variable speed fans Reduce energy consumption during off-peak cooling
periods.
• Green refrigerant Environmentally friendly refrigerant that can offer LEED points.
For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
Modular/High Density Air Conditioning
Hot Aisle Containment
Hot aisle containment for high-density configurations.
Mixing of hot and cold air streams in the data center lowers availability of IT equipment. Returning the warmest possible air to the
computer room air conditioners increases the efficiency and capacity
of the system. The hot aisle containment system ensures proper air
distribution by completely separating supply and return air paths.
The hot aisle is sealed off using doors and transparent ceiling tiles
that extend the width of the hot aisle. Ceiling tiles are available for
both 19” and 23” racks. Two-rack kits complete with ceiling tile and
hardware are available for future expansion.
• One-way locking door Secures the hot aisle while allowing for quick exit
in case of emergency.
Features and Benefits
• Scaleable densities Allow higher density cooling to be achieved by
integrating the hot aisle containment system with in-row architecture.
Availability
• Modular design Modular design provides scalable solutions to add cooling
as demand increases.
• Cable access brush strip Blocks air from escaping through holes
surrounding cabling.
Total Cost of Ownership
Agility
• Ceiling tiles Close off the top of the hot aisle to prevent warm air from
mixing with room air.
• Energy efficiency Increases cooling capacity of the associated air
conditioners without driving up power consumption. Rack Air Containment
Modular air containment system designed to maximize
cooling predictability, capacity, and efficiency.
Deployment of high density loads in IT environments can create areas
of unpredictable cooling performance. APC’s Rack Air Containment
is a modular system designed to work in conjunction with APC
NetShelter® SX enclosures and InRow™ cooling units to provide maximum cooling predictability, capacity, and efficiency. By attaching
to the rear of the NetShelter SX, air exhausted from IT equipment
is forced to pass through the cooling unit where it is conditioned.
This ensures that warm exhaust air does not find its way back to
the air inlets of installed servers. N+1 and 2N configurations allow
for maximum availability. Front containment can also be added to
Availability
provide additional isolation and noise dampening.
• Redundancy Systems can be configured to included an additional InRow
cooling unit to provide N+1 or 2N redundancy.
Features and Benefits
• Integrated pressure sensors Pressure sensors in the InRow cooling units
provide fan speed control for optimum system efficiency.
Adaptability
Convenience
• Modular design Compatible with standard NetShelter SX racks, providing
maximum system flexibility and scalability.
• Noise dampening Containment of both front and rear provides reduction of
noise caused by installed equipment.
• Front containment Ensures cold supply air is not captured by neighboring
equipment.
• Plexiglass door inserts Provides required air containment and a consistent
look across the racks while allowing visibility to installed IT equipment.
• Rear containment Ensures server exhaust air is returned to the InRow
cooling units for maximum cooling predictability.
• Easy to install Innovative design allows for fast, easy installation by almost
anybody.
For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Air Distribution/Fans
Wiring Closet Ventilation Unit
Rapidly deployable wall and ceiling mount heat removal for
wiring closets.
Wiring closet heat loads are rising due to deployment of technologies such as VoIP and Power over Ethernet. The Wiring Closet
Ventilation Unit is a rapidly deployable wall and ceiling mount heat
removal system designed specifically for the wiring closet environment. By exhausting hot air from the closet to an adjacent space
it allows conditioned air (entering through the Air Intake Grill) to
cool the load. Dual fans increase availability while LED status indicators and dry contact outputs enhance the unit’s manageability.
Selectable fan speeds allow the user to choose between maximum
performance and quiet operation.
Features and Benefits
Availability
Manageability
• Fault-tolerant fan system In event of a fan failure the remaining fan
automatically speeds up to compensate. Fans are N+1 redundant up to 300
CFM of airflow. • Predictive failure notification Maximizes system availability by providing
early warning of required fan replacement. • Selectable speed fans Selectable fan speed (high/low) via toggle switch
provides options for maximum performance or quiet operation. • Dry contact output Provides remote notification of failures when used with
APC environmental monitoring unit or system. • LED status indicators Provide visual notification of fan failure. Adaptability
• Multiple mounting methods Flexible design allows for both drywall and
ceiling mount installations. • Easy to install Innovative design allows for fast, easy installation by almost
anybody. ACF301
Cooling Capacity Options
• Hardwire capable For installations where hard wiring is required or
prefered. Air Flow
• Architecturally neutral Unobstrusive design and coloring
blends in with the surroundings. Input Power
Nominal Input Voltage
Input Connections
3 kW of heat removal
475.00 CFM
100–240V, 50/60 Hz
85 Watts Input
Hard Wire 3-wire, IEC-320 C14, NEMA 5-15P
Maximum Height
12.80 inches (325 mm)
Maximum Width
17.10 inches (434 mm)
Maximum depth
7.00 inches (178 mm)
Color
Regulatory Approvals
Standard Warranty
For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
White
cUL Listed,CE,EN 55022 Class A,EN 55024,
FCC Part 15 Class A,VCCI
2 years repair or replace
Air Distribution/Fans
Rack Air Removal Unit SX
Performance heat removal for high-density equipment in
NetShelter® SX and VX enclosures.
High-density equipment creates an environment where traditional
air distribution methods are often not effective. Densely packed
enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, ducting it to the return air plenum and eliminating hot spots. Through
automatic fan speed adjustment based on temperature or power
consumption, the fans will self-adjust for optimal performance.
With a unit-mounted LCD display users can view temperatures at
the rack, monitor alarm conditions and adjust unit set points. The
integrated network management card allows for remote monitoring and control of the Rack Air Removal Unit SX. This space-saving product mounts to the back of either the NetShelter SX or VX
enclosure – requiring zero U space.
Features and Benefits
Manageability
• Network manageable View the user interface with a browser. Gives quick
access from anywhere on the network
ACF400
Cooling Capacity Options
• InfraStruXure® Manager compatible Enables centralized management
via the APC InfraStruXure Manager.
Air Discharge Patterns
• Temperature monitoring Allows up to 3 remote sensors to monitor rack
inlet temperature.
Nominal Input Voltage
23 kW
Upflow,Ducted
Air Flow
• LCD display Accessible without opening the door for easy operation.
Allows user to locally monitor and control the unit.
Input Power
Availability
Input Connections
• Fault-tolerant fan system In event of a fan failure the remaining fans will
speed up to compensate. Fans are N+1 redundant up to 1500 CFM of airflow.
Control panel
• Dual A-B power inputs Draw power from the UPS for power protection
with dual feeds for redundancy.
Maximum Width
2000 CFM
1200 Watts
• Field replaceable components Fans and electronics module can be
readily replaced without uninstalling the unit.
Adaptability
50/60 Hz
IEC-320 C14, NEMA 5–15P
Multi-function LCD status and control console
Maximum Height
1918.00 mm
597.00 mm
Maximum depth
Net Weight
Color
Regulatory Approvals
Standard Warranty
Upflow,Ducted
100V,120V,200V,208V,230V
Input Frequency
• Ducted Exhaust System Removes hot air from the data center to prevent
recirculation and eliminate air mixing.
ACF402
737.00 mm
254 mm
67.27 KG
77.27 KG
Black
cUL Listed,CE,EN 55022 Class A,EN 55024,FCC Part 15 Class
A,ICES-003,IEC 61000-3-2,IEC 61000‑3‑3,UL Listed,VDE,VCCI
2 years repair or replace
• Adjustable mounting frame The frame can mount on Netshelter SX or VX
enclosures and extends to accommodate 42U, 47U or 48U rack heights.
• Zero “U” Solution Mounts to the rear of the rack, leaving valuable rack
space for other equipment.
Total Cost of Ownership
• Easy to install Innovative design allows for fast, easy installation by almost
anybody.
• Variable speed fans Reduce energy consumption during off-peak cooling
periods.
• Increased capacity Higher rate of heat removal allows more equipment to
be installed in each rack.
10
For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Air Distribution/Fans
Rack Air Distribution Unit
Air distribution for power dense enclosures and low
pressure areas
The Rack Air Distribution Unit is a 2U fan unit that works with an
existing precision air conditioning system to deliver cool air to the
equipment contained in a rack enclosure. The Rack Air Distribution
Unit connects into the raised floor and pulls supply air directly into
the enclosure. This prevents the conditioned air from mixing with
warmer room air before reaching the equipment.
The Rack Air Distribution Unit minimizes temperature differences
between the top and bottom of the enclosure. It also prevents hot
exhaust air from recirculating to the inlet of the enclosure.
The product is recommended for rack enclosures with loads
greater than 1.5kW and can provide airflow for loads up to 3.5kW.
It is also ideal for enclosures in raised floor environments where
underfloor air distribution is inadequate.
Air Flow
Amp Draw Nominal
Nominal Input Voltage
Input Power
Input Frequency
Features and Benefits:
Availability
ACF001
ACF002
ACF003
503 CFM
420 CFM
503 CFM
2A
1A
2A
120V
208V, 230V
100V
240 Watts
230 Watts
200 Watts
60 Hz +/- 1Hz
50/60 Hz
50/60 Hz
C-13
NEMA 5–15P
C-13
IEC-320 C14
Rack Height
Input Connections
2U
• Dual fans Deliver air to equipment in the rack where floor tile velocity is
inadequate for proper cooling.
Maximum Height
• Raised floor duct Delivers cool, conditioned air directly from the raised
floor to the inlet of the IT equipment.
Maximum depth
737 mm
Agility
Net Weight
18.64 KG
Color
• Air filtration Removes dirt and other particulates from the intake air for
cleaner supply air.
• Fan control switches Users can turn one or both fans on and off
depending on the heat load.
Maximum Width
Regulatory Approvals
Standard Warranty
C-13
NEMA 5–15P
89.00 mm
422.00 mm
421.00 mm
Black
UL Recognized
CE,
UL Recognized
METI Denan,
UL Recognized
2 years repair or replace
• Mounting rails Adjustable depth allows the unit to fit APC's NetShelter®
enclosure or other 19" EIA-310-D enclosure.
• Fan guards A safety measure that provides protection from the fan opening
by covering the inlet.
Total Cost of Ownership
• Dual A-B power inputs Draw power from the UPS for power protection
with dual feeds for redundancy.
For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
11
Air Distribution/Fans
Rack Side Air Distribution Unit
Air distribution for networking equipment with side to
side airflow
Housing equipment with side to side airflow creates many challenges for IT and facility managers, particularly in regards to cooling. Because most enclosures are designed for a front to back airflow pattern, it is difficult to maintain ideal operating temperatures
on side to side airflow equipment. The Rack Side Air Distribution
Unit allows for greater security and organization by allowing racks
to be placed adjacent to one another without impeding airflow.
The Rack Side Air Distribution Unit is a 2U rack mountable air
distribution product for networking equipment or servers with
Nominal Input Voltage
side to side airflow. It pulls in conditioned air from the front of
Input Power
the rack and distributes it to the side air intake of the networking
Input Frequency
equipment. This extends equipment life by providing proper inlet
temperatures.
ACF201BLK
ACF202BLK
120V
208V, 230V
150 Watts
60Hz
50/60Hz
Air Flow
Amp Draw Nominal
260 CFM
2A
1A
Net Weight
32 lbs (15kg)
This product is recommended for one or more networking products
Max. Height
3.44 inches (87.4 mm)
that are stacked consecutively in a rack. Rack Side Air Distribution
Max. Width
16.98 inches (431 mm)
Units may be placed above and/or below the networking equip-
Max. Depth
26.34 inches (669 mm)
ment. Airflow pattern is user configurable via an interchangeable
Color
Approvals
air turning vane.
Standard warranty
Black
UL Recognized
CE
2 years repair or replace
Features and Benefits:
Availability
• Dual fans Deliver air to equipment in the rack where floor tile velocity is
inadequate for proper cooling.
• Fan control switches Users can turn one or both fans on and off
depending on the heat load.
Agility
• Mounting rails Adjustable depth allows the unit to fit APC's NetShelter®
enclosure or other 19" EIA-310-D enclosure.
• Fan guard A safety measure that provides protection from the fan opening
by covering the inlet.
Total Cost of Ownership
• Dual A-B power inputs Draw power from the UPS for power protection
with dual feeds for redundancy.
• Air turning vane Directs air up or down the side of the rack, supplying cool
air to the inlet of side to side airflow equipment.
Manageability
• LED status indicators Indicate the operating condition of the unit including
power-on and alarm state.
12
For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Room Air Conditioning
NetworkAIR® FM
Modular floor mount precision air conditioning for
environmentally sensitive equipment areas
The NetworkAIR FM utilizes leading edge precision air technologies. Modular construction, variable frequency drives, dedicated
dehumidification, tandem scroll compressors, and front service
access are all integrated into one high efficiency system. A scalable design enables customers to meet the changing needs of their
environments.
Features and Benefits
Availability
• Tandem scroll compressors Quiet and efficient operation of scroll
compressors, connected on a common circuit for staged capacity control
(N/A chilled water systems).
• Direct drive motors Stress on bearings is nearly eliminated, increasing
useful life. Allows integral fan/motor assembly to be factory balanced which
lowers vibration and expedites startup. Eliminates the need for unreliable
belts, pulleys and special bearings.
• Variable frequency drives Enable the fans to be soft started, saving
energy during power up. Controlling the motor speed simplifies the
adjustment for static pressure and gives the option of back-draft prevention.
Economy
• Dedicated dehumidification Boosts system efficiency by adding latent
capacity without overcooling or increasing the requirement for reheat,
resulting in up to 15% lower energy consumption (N/A chilled water
systems).
• SCR electric reheat Modulates capacity to save energy. Exacting amounts
of reheat loaded equally on all three phases.
• Steam humidifier Humidity is managed through a self-contained steam
canister humidifier for maximum efficiency and ease of maintenance. The
pure-steam canister maintains consistent capacity output, and requires very
little scheduled maintenance.
Manageability
Serviceability
• Microprocessor controller Provides proactive control and real-time
monitoring via a four line, eighty character alphanumeric display.
• Programmable input/output contacts Allows device contacts to be
connected to the air conditioner and mapped to customer outputs or system
alarms.
• Front service access The system has full service, front access for routine
servicing of components. Front access also narrows the footprint of the
system making it possible for units to be placed side by side.
Protection
• Network interface Provides management by connecting the device directly
to the network with a dedicated IP address, avoiding the need for a proxy
such as a server. Management is available via Web browser, Telnet or SSH.
Notification features inform you of problems as they occur.
• Double-walled panels Separates insulation from the air stream, which
prevents periodic maintenance of the insulation and reduces noise levels.
Small particles of insulation can be picked up by the air stream if not isolated.
• Redundant group control Allows up to 4 groups of precision air
conditioners to communicate with each other for redundancy, demand
fighting prevention, mode assist, and global sharing of certain settings.
FM-DX 60Hz
Cooling Options
FM-CW 60Hz
Air, Water, Glycol, Economizer, Multicool
Humidification Capacity
Compressor Type / Refrigerant
FM40H-AGB-ESD
Chilled Water
10 lbs/hr
Chilled Water
10 lbs/hr
Tandem Scroll / R22
Input Frequency
FM40B-CFB-ESD
Air
N/A
Tandem Scroll / R407C
N/A
60 Hz
50 Hz
Nominal Input Voltage
208V 3PH, 480V 3PH, 600V 3PH
400V 3PH
Air Discharge Patterns
Downflow, Upflow Front Return, Upflow Rear Return
Control Panel
Net Weight
Downflow
Microprocessor Controller
2,360 lbs (1072.73 kg)
1,180 lbs (536 kg)
2,360 lbs (1072.73 kg)
Max. Height
76.89 inches(1953.01 mm)
Max. Width
70.87 inches (1800.1 mm)
Max. Depth
35.00 inches (889.00 mm)
Approvals
Standard Warranty
CSA, MEA, UL Listed
1,180 lbs (536 kg)
CE, Eurovent
1 year (parts only) optional extended warranties available.
For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
13
Room Air Conditioning
NetworkAIR® PA*
Portable, self-contained air conditioning solutions for small
rooms and data closets
Inconsistent and high temperatures can lower the expected life of,
and permanently damage your electronic equipment. IT refreshes
and equipment relocation result in unpredictable and ever-changing environments. The NetworkAIR PA provides portable cooling
for your sensitive electronic equipment to meet the environmental
demands of small rooms and data closets.
This self-contained solution does not require an external condenser, refrigerant piping, or building water source for operation.
Heat is rejected to a drop ceiling or adjacent area via a flexible duct
kit. The NetworkAIR PA can be installed quickly and inexpensively,
without the need for building modifications.
Features and Benefits:
Availability
• Automatic restart Returns the unit to its last operating status in the event
of a power failure, in order to protect the compressor and the environment.
(Not available on the AP7003 unit).
• Ducting kit Allows hot air to be removed and distributed to a drop ceiling
or hard-ducted return. This increases the efficiency of the computer room air
conditioning system in both capacity and dehumidification.
ACPA4000
Cooling Capacity
3.9kW
Air
Compressor Type
Rotary
Nominal Input Voltage
Input Power
Input Frequency
Agility
Air Flow
120V
1,610 Watts
692 Watts
60Hz
Coolant
• Replacement ceiling tile Fits into a standard drop ceiling to provide a
connection point for the ducting kit. (Not available on the AP7003 unit).
1.6kW
Cooling Options
• High head pressure protection Prevents compressor damage (not
available on AP7003 unit).
• Easy to install Self-contained, air cooled design allows for fast, easy
installation.
AP7003
R22
600 CFM
170 CFM
Condensate Tank
N/A
3.5 qt
Condensate Pump
1.6 gal/hr
Approvals
Standard Warranty
N/A
UL Listed
1 year repair or replace
• Casters Provide flexibility to move the unit to wherever cooling is required.
Manageability
• Network manageable Remotely monitor and control NetworkAIR PA4000
environmental information from anywhere on the network via a Web browser
(not available on the AP7003 unit).
• LED status indicators Four (4) external status indicator LEDs represent:
major alarm; minor alarm; check log (new alarm/warning has occurred);
system on (evaporator blower is running). Not available on the AP7003 unit.
• On/off scheduling Allows the user to determine when the unit operates,
saving energy costs. (Not available on the AP7003 unit).
* available in North America only
14
For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Heat Rejection
Air Cooled Modular Chillers*
Air Cooled Chillers for air conditioning equipment in data
centers, server rooms and wiring closets.
APC air cooled chillers for air conditioning equipment in data
centers are a new generation of leading-edge technology. These
all-in-one integrated packages reduce time and cost of installation.
Features and Benefits:
Manageability
• Microprocessor controller Provides proactive control and real-time
monitoring via a four line, eighty character, alphanumeric display.
• ModBus translator Optional feature allows integration with Building
Management System.
Total Cost of Ownership
• Variable speed fans Reduce energy consumption during off-peak cooling
periods.
• Integrated hydronics package Includes all the necessary components to
make one connection to the chilller without the need of external connections
to auxiliary equipment such as pumps, increasing the speed of deployment.
Availability
• Scroll compressors Utilize few moving parts for increased reliability and
life expectancy.
• Independent power feed Optional feed to the pumps allows for wiring to
the UPS, thus ensuring chilled water availability during generator start-up
when used with a storage tank.
• Dual redundant pumps Provide reliable chilled water flow sized for full
capacity.
• Low ambient controls Enable chiller operation in temperatures down to -20°F.
Convenience
• Optional storage tank Fits under chiller without increasing footprint.
SKU Series
Capacity
UPSable pump (optional)
Storage tank option
Windbaffle option
Voltages
ACCH050
ACCH084
ACCH120
ACCH167
ACCH200
ACCH220
50kW
84KW
120KW
167KW
200KW
220KW
Yes
Yes
Yes
Yes
N/A
N/A
ACTA1100
ACTA1101
ACTA1102
ACTA1102
N/A
N/A
ACAC30001
ACAC30002
ACAC30003
ACAC30004
ACAC30005
ACAC30005
208/3PH, 480/3PH
208/3PH, 480/3PH
208/3PH, 480/3PH
208/3PH, 480/3PH
208/3PH, 480/3PH
208/3PH, 480/3PH
Height in inches*
52
52
52
52
90
90
Width in inches*
82
108
108
108
95
95
Depth in inches*
Weight in lbs*
43
43
90
90
89
89
1298
1819
3134
3603
4705
4911
Standard Warranty
1 year (parts only), optional extended warranties available
* Weights and dimensions do not include storage tank or windbaffles
* available in North America only
For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
15
S
ince 1981, APC has been a global leader in power availability solutions, setting the
industry standard for quality, innovation, and support. From its corporate headquarters in West Kingston, Rhode Island, APC operates sales offices throughout
the world and manufacturing facilities on four continents and distribution facilities on
five continents. APC ships products to over 150 countries.
Over 30 million satisfied customers worldwide depend on APC’s Legendary Reliability®.
Propelled by real-world experience and a drive towards technological innovation, APC
has the experience, scale, global presence, and stability to respond to emerging IT
availability needs.
As the recipient of hundreds of awards worldwide, APC is recognized for excellence in both its business
and product performance. Every year since 1999, APC has been named to the Forbes Platinum 400
list of the Best Big Companies in America. For 11 years in a row, APC has received the Channel
Champion award in the UPS category.
es
Strategi
Cooling igh
-h
for Ultra cks and
ra
density ers
rv
blade se
Choose the optimal service solution to increase your system availability.
Receive your FREE APC white paper “Cooling Strategies for Ultra-High
Density Racks and Blade Servers”. Visit us online at http://promo.apc.com
and enter key code s369y.
APC’s quality
system is
certified by
ISO 9002
standards
For more information call:
Tel: 800 800 4APC - US & Canada
Tel: 401 789 0204 - World wide
APC Corporate
APC North America
132 Fairgrounds Road
West Kingston, RI
02892 USA
Call: 800 800 4APC
Fax: 401 789 3710
APC Latin America
5301 Blue Lagoon Drive
Suite #610
Miami, FL 33126 USA
Call: 305 266 5005
Fax: 305 266 9695
APC Europe
APC Ireland
Ballybrit Business Park
Galway, Ireland
Call: +353 91 702000
Fax: +353 91 756909
APC Asia Pacific
APC Australia
Level 13 The Denison
65 Berry Street
North Sydney, NSW 2060
Call: +61 2 9955 9366
Fax: +61 2 9955 2844
Visit: www.apc.com
e-mail: apcinfo@apc.com
Web Support: : support. apc.com
©2007. All rights reserved. All APC trademarks are property of American Power Conversion. Other trademarks are property of their respective owners. Specifications are subject to change without notice. PART# 996-2854B