Water Technologies Water Purification Products and Services Catalog This electronic catalog features programming which allows easy point-and-click navigation. The catalog features a “Main Table of Contents” and actions buttons to return to “Section Table of Contents” or to return to the prior selection “Go Back” buttons. “Main Table of Contents” and “Section Table of Contents” allow the user to scroll over subjects and advance by clicking on the titles. Click here to enter the catalog. At Siemens Water Technologies, our mission is to provide products and services to meet your water treatment needs, any time, any place. As one of the world’s largest water treatment companies, we offer a wide range of products and services, combined with experience and technical knowledge you can trust. We will deliver a solution that meets even the most stringent specifications. And, because your satisfaction is important to us, we stand behind the quality of our products and services. Main Table of Contents S 1 U M M A R Table of Contents Y PRODUCT QUICK REFERENCE GUIDE BY INDUSTRY . . . . . . . . . . . . . . . . . . 2 WAT E R P U R I F I C AT I O N PRODUCTS AND SERVICES C ATA L O G WATER TREATMENT TECHNOLOGIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 WASTEWATER CAPABILITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 SUPPORT SERVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 WATER QUALITY STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 TRADEMARK STATEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253 For a detailed table of contents, refer to each section’s table of contents. BACK 2 PRODUCT QUICK REFERENCE GUIDE BY INDUSTRY C O N S U LT T H E S E G U I D E L I N E S T O F I N D S I E M E N S WAT E R T E C H N O L O G I E S P R O D U C T S A N D S Y S T E M S F O R Y O U R I N D U S T RY . I N D U S T R I E S A R E L I S T E D AT T H E T O P. ACTIVATED CARBON FILTERS CT Series Carbon Towers HOT Series Systems l l l l KF Series l l Mobile l l l l l l l l l l l l VP Series CHEMICAL FEED SYSTEMS CLARIFIERS Package Precipitators DEAERATORS SLH Deaerating Heaters DG Series Forced Draft Decarbonators l l l l l l l l l l l l l l l l Deionization Recirculating Systems (DIRS) l l l l l l l l l VP Series Mixed Beds Mobile l l l l l l l l l l l l l l l l l l Use this table only as a guideline. Products may be used in other industries depending on your specifications. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK l l l l l l l VP Series Two Beds l l l l l l CDI-LX™ Systems l l l l l l l l l l l l l l l l CDI-LX™ Low Profile Kits l l l DEIONIZATION l l l Main Table of Contents l l l l l l l l l l l l l l l l l l l l l l l l l l l l 3 PRODUCT QUICK REFERENCE GUIDE BY INDUSTRY C O N S U LT T H E S E G U I D E L I N E S T O F I N D S I E M E N S WAT E R T E C H N O L O G I E S P R O D U C T S A N D S Y S T E M S F O R Y O U R I N D U S T RY . I N D U S T R I E S A R E L I S T E D AT T H E T O P. SERVICE DEIONIZATION (SDI) Tanks, Deionizers, Carbon and Resin WATER SYSTEMS INTEGRATED l EPV™ Systems PreVUE® Systems VP Series l 40 Series Pharm40 Series l l l l l l BevMAX™ Vantage™ M21, 41, 43 Vantage™ M83, M84 l Vantage™ M280 l Vantage™ M240 l l l l l l l l l RO SYSTEMS MicRo Series l l MULTIMEDIA FILTERS AVGF Gravity Filters Mobile l l APEX™ Systems KF Series l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Use this table only as a guideline. Products may be used in other industries depending on your specifications. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Main Table of Contents 4 PRODUCT QUICK REFERENCE GUIDE BY INDUSTRY C O N S U LT T H E S E G U I D E L I N E S T O F I N D S I E M E N S WAT E R T E C H N O L O G I E S P R O D U C T S A N D S Y S T E M S F O R Y O U R I N D U S T RY . I N D U S T R I E S A R E L I S T E D AT T H E T O P. (continued from page 3) MEDICAL RO (DIALYSIS) Med-RO® RX Series SOFTENERS KF Series VP Series l l l l l l l l l l l l l l l l l l l l l l l l l l l l LABORATORY PRODUCTS PURELAB® Ultra PURELAB® Classic PURELAB® UHQ Water Purification Systems PURELAB® Option Water Purifiers MEDICA® l l MEDICA® Pro REVERSE OSMOSIS SYSTEMS PURELAB® Prima CENTRA® (HF) MODULAB® (HF) l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Use this table only as a guideline. Products may be used in other industries depending on your specifications. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK l Main Table of Contents l l 5 Water Treatment Technologies TA B L E O F CONTENTS Removal of Common Contaminants Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Activated Carbon Filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Chemical Addition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Clarification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Continuous Electrodeionization (CEDI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Dealkalization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Degasification/Deaeration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Deionization (DI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Distillation for WFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Reverse Osmosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 S3™ Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Sanitization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Softening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Ultraviolet Sterilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 BACK Main Table of Contents 6 Removal of Common Contaminants COMMON CONTAMINANTS Alkalinity TECHNOLOGY Carbon Dioxide Calcium, Magnesium Activated Carbon Filtration Chlorine, Chloramines Inorganics l Chemical Addition l l l l Continuous Electrodeionization (CEDI) l l l l Dealkalization l l l Clarification Degasification/Deaeration l Deionization l Distillation l l l l l l l Filtration Reverse Osmosis (RO) l Sanitization Softening l Ultraviolet Sterilization l l Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 7 COMMON CONTAMINANTS Iron (dissolved) Microbiologicals Organics Particles Pyrogens Silica 8 l l l Description of Technology l 8 l 8 l l 9 9 10 l l l l l l l l 10 l 11 12 l l l l l l l l l l 14 14 15 l l l 15 Removal of Contaminants is based on the proper use of equipment in the appropriate treatment train. Products are combined to form the best solution for you. Use this table only as a guide. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 8 WATER TREATMENT TECHNOLOGIES ACTIVATED CARBON FILTRATION Activated carbon is carbon that has been processed at high temperature to form a material with high adsorptive capacity. Usually available in a granular or powdered form, activated carbon is used to remove chlorine, chloramines and dissolved organics from water. Carbon filters are frequently used as pretreatment to membrane and ion exchange-based systems that can be damaged by oxidants such as chlorine. Two types of activated carbon media: • High-capacity granular carbon for chlorine removal. • Organic reduction carbon that uses bituminous coal activated at high temperature for adsorption of both high and low molecular weight organics. There are several different types of activated carbon filters available, including service carbon, backwashable carbon and steam or hot-water-sanitizable carbon. CHEMICAL ADDITION Chemicals are often added during or after industrial and municipal water treatment to enhance the treatment process or further treat the water to meet specific customer requirements. The water’s pH is sometimes adjusted to meet the operating specifications required by certain membranes or ion exchange resins. This is accomplished by adding caustic soda to raise the pH, or acid to reduce the pH. Dispersants or antiscalants are sometimes added to prevent scaling from a concentration of specific ions in the water. Oxidizing agents, sequestering (chelating) agents and reducing agents can also be added to the water. Oxidizing agents are used to prevent microbial growth. Sequestering agents help prevent hardness minerals, such as calcium and magnesium, from depositing on the surface of water systems, system piping and tanks. Reducing agents, such as sodium metabisulfite, are added to neutralize oxidizing agents, such as ozone or chlorine, or remove oxygen. CLARIFICATION Clarification is a multi-step process that reduces turbidity and suspended matter. It also reduces iron and removes color, taste and odor in the water by adding oxidizing agents, such as chlorine. Clarification consists of three steps: coagulation, flocculation and sedimentation. During the coagulation stage, chemical coagulants or pH-adjustment chemicals are used to destabilize the particles. During the flocculation stage, other chemicals are added to take the previously destabilized particles and make them stick together. They become agglomerated and form a floc. During sedimentation, the floc settles by gravity and separates from the water. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 9 WATER TREATMENT TECHNOLOGIES CONTINUOUS ELECTRODEIONIZATION (CEDI) Continuous Electrodeionization Siemens CDI® System ¶ Feed Water NaCl high-purity water without the problems and costs associated with regeneration chemicals and waste neutralization. It is used to further deionize RO product ¶ º Continuous Electro Deionization (CEDI) is a continuous process for producing ¶ ¹ water and remove carbon dioxide, silica and total organic carbon (TOC). CEDI systems use ion exchange membranes, ion exchange resins and electricity to Cl– produce consistent high-quality water with no regeneration downtime. When fed with RO product water, CEDI systems achieve better than 99.5% salt Cl– Na+ Na+ (+) Anode removal and produce up to 18.2 mΩ-cm (0.055 micromho/cm) resistivity · ¸ OH– quality water. ¸ (–) Cathode ¶ How a CEDI system works: Feedwater entering the system flows inside resin/membrane product and concentrate compartments. The feed stream flows parallel to the membrane H+ Product Water H2O ¼ Waste Stream (NaCl) Concentrate Ï Ë Ì surface. Í captured anions through the anion membranes. Resins capture dissolved ions. Electric potential drives captured cations through the cation membranes and Cation-permeable membranes transport cations out of the diluting compartment, but prevent anions from leaving the concentrate Î compartment. Ï Ð but prevent cations from leaving the concentrate compartment. Anion-permeable membranes transport anions out of diluting compartment, Waste stream removes concentrated ions from the system. Product water leaves the system. DEALKALIZATION Dealkalizers remove alkalinity from feedwater for process, boiler feed (lowpressure boilers) and cooling-tower applications. Chloride cycle dealkalizers use strong-base anion ion exchange resins that are regenerated with salt to remove bicarbonate, carbonate, sulphate and nitrate ions from high alkalinity waters by exchanging them for chloride ions. Split stream dealkalizers “split” the feedwater, so a portion goes to the hydrogen-form cation resin unit, converting all alkalinity to carbon dioxide, and the other portion to the sodium-form cation resin unit (softening). The effluents of both units are then re-joined to produce dealkalized water. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 10 WATER TREATMENT TECHNOLOGIES DEGASIFICATION/DEAERATION Degasification, or gas stripping, removes undesirable dissolved gases, such as oxygen, carbon dioxide, ammonia and hydrogen sulfide from water. The gases are removed by exposing the water to a vapor phase that is missing the gases to be eliminated. Degasification equipment is classified as ebullition, tray or drip and spray type units. One type of drip degasifer is the forced draft degasifer, which removes dissolved gases from water without changing its ambient temperature. Forced draft degasifiers are particularly useful for eliminating carbon dioxide formed by the acid used to adjust raw water alkalinity prior to reverse osmosis treatment. They also reduce hydrogen sulfide and other dissolved gases in water, and may be used to oxidize dissolved iron and manganese for subsequent removal by a filter or clarifier. In this type of operation, they are commonly referred to as aeration units since they add oxygen to the water for oxidation. DEIONIZATION Deionization removes dissolved minerals and salts, as well as some dissolved organics, from water using the process of ion exchange. During ion exchange, certain ions of a given charge are replaced (or exchanged) with different ions of the same charge. These replacement ions are provided by ion exchange resins. Positively charged ions in the water (cations), such as calcium, magnesium and sodium are removed by cation exchange resins and replaced with hydrogen ions. Negatively charged ions (anions), such as chloride, nitrate and sulfate are removed by anion exchange resins and replaced with hydroxide ions. The hydrogen and hydroxide ions then unite to form water molecules. Deionization is conducted in pressure vessels containing the ion exchange resins. Typical deionization systems consist of separate cation and anion vessels connected in series (called a separate bed or two bed). These systems produce water up to 1 megohm-cm quality. For higher purity water, a single vessel containing a mixture of cation and anion resins (called a mixed bed) is employed. Mixed bed deionizers can produce water up to 18 megohm-cm quality. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 11 WATER TREATMENT TECHNOLOGIES Service Deionization Service deionization (SDI) refers to portable deionization equipment that is designed for off-site regeneration. A SDI system typically consists of a prefilter, activated carbon and deionization (DI) tanks, interconnecting hoses, pressure gauges, a pressure regulator and quality indicators. SDI systems may include separate bed tanks, mixed bed tanks or a combination of the two, depending on the product water quality requirements. When the resins in the tanks reach exhaustion (are no longer capable of effective ion exchange), the tanks are disconnected and replaced with tanks containing freshly regenerated resins. The tanks containing the exhausted resin are transported to a regeneration facility. With SDI, the customer does not make a major capital investment, and does not handle hazardous regeneration chemicals (acids and caustics). Automatic Deionization Deionizers that are regenerated at the customer site are referred to as automatic deionizers (Auto DI). During regeneration, the cation resin is treated with acid, usually hydrochloric acid, and the anion resin is treated with caustic. Automatic deionizers contain the necessary piping, valves and controls, water quality monitors and alarms to regenerate the system when required. DISTILLATION FOR WFI Distillation is a process whereby feedwater is vaporized at a pressure slightly above atmospheric, leaving non-volatile impurities behind. The vapor passes through a separator where heavier particles are raised. The vapor is then compressed to a higher temperature and pressure. This high temperature vapor transfers its latent heat to the feedwater as it condenses (leaving noncondensables behind). Degassing of the distillate further increases the purity of the water. The steam heats the water in the evaporators and the extra heat is then recovered. Vapor compression distillation is often used in purified water production to produce hot distillate in systems where the water is stored and distributed at an elevated temperature (176˚F/80°C). Distillation removes salts, colloids, particles, bacteria and pyrogens from water down to 10 parts per trillion (ppt). It is used for producing Water for Injection (WFI) and USP Purified Water. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 12 WATER TREATMENT TECHNOLOGIES FILTRATION Filtration removes solid matter and suspended impurities from a fluid stream by passing it through a variety of devices, including microporous filters (which include depth, screen and surface filters), ultrafiltration units, greensand, activated carbon, diatomaceous earth and multimedia filters. Microporous filters remove particles according to the filter’s pore size. They are often used before other water purification equipment, such as deionization and reverse osmosis systems, and are also used as polishing filters to remove resin and carbon fines, colloids and microorganisms. Surface Filtration Depth Filtration Microfiltration Microfiltration, also known as surface, membrane, screen and absolute filtration, uses microporous filters to remove particles and bacteria in the approximate range of 0.05 to 10 microns. Microporous filter ratings correspond to the largest hole or pore in the filter material matrix, which means anything larger will be “absolutely” removed. Microporous filters are often used as “polishing” filters to remove contaminants that were not removed by depth filtration. Multimedia Filtration Multimedia filters offer a highly efficient means of removing suspended particulate matter from water. The three layers of media are selected for their particular size, specific gravity and ability to trap particles of specific size ranges. As water flows downward through the bed, it encounters layers of media with decreasing porosity, so successively smaller particles are trapped in each layer, providing true depth filtration. The filters provide high clarity water either for direct use or for pretreatment to softeners, deionizers or reverse osmosis systems. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 13 WATER TREATMENT TECHNOLOGIES Nanofiltration Nanofiltration is a crossflow-membrane separation process that removes selected salts, most organics and particles in the 300 to 1,000 molecular weight range. Nanofiltration softens the water without the need for salt regeneration. Ultrafiltration Ultrafiltration uses membranes to retain undissolved and dissolved contaminants that are larger than the nominal molecular weight cutoff rating (NMWC) of the membrane (typically 5,000 to 500,000 daltons). Ultrafiltration removes particles, colloidal silica, microorganisms and pyrogens. Osmosis REVERSE OSMOSIS The natural process of osmosis occurs when solutions with different Osmotic Pressure concentrations of salts are separated by a semi-permeable membrane. As osmotic pressure drives water through the membrane, the water dilutes the more concentrated solution until equilibrium is achieved. Reverse osmosis (RO) uses external pressure to reverse the process of osmosis. The water is forced by this external pressure through a semi-permeable membrane from a more concentrated solution to a less concentrated one. The RO membrane allows the water to pass through while retaining (or holding back) a large percentage of the Membrane dissolved inorganics, organics, bacteria and pyrogens. The pure water collected Reverse Osmosis on the downstream side of the membrane is called the permeate or product water. RO membranes remove 99% of the feedwater particles, colloids, bacteria, Pressure pyrogens and organics greater than 200-300 molecular weight (MW) range, or larger than the membrane’s pore size of 150 to 200 Ångströms. It removes 9099% of dissolved inorganics. The greater the ionic charge of the inorganic contaminants, the more likely they will be removed by the RO membrane. RO Membrane Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 14 WATER TREATMENT TECHNOLOGIES S3™ SYSTEM S3™ system is a patent-pending technology developed by Siemens Water Technologies for high-purity water applications. S3™ technology is used to produce purified water, non-compendial water or still feed water. The technology improves upon proven active sanitization methods with a unique, start/stop mode of operation. Conventional systems require continuous water recirculation for microbial control, thereby wasting significant energy, water and consumables. The Siemens’ S3™ process implements periodic short, high temperature heat cycles of up to 80˚C prior to startup for water production. The high temperature hold period is typically 5 minutes or less. The shortened heat cycles result in water conservation and energy reduction when compared with continuous recirculation methods. The water and energy cost savings often significantly exceed the system capital cost over the lifetime of the system. SANITIZATION Water purification systems and filters can become contaminated by bacteria that grow inside them. Although most water systems remove the majority of organic material from the feedwater, gram negative bacteria are able to survive and multiply in water that contains only small amounts of organic matter. The bacteria eventually form a layer of biofilm on the water system surfaces, and this biofilm continuously releases microbes into the water. Bacteria also forms pyrogens that may elevate organic levels in the product water. For this reason, proper sanitization of water systems is essential for optimum performance. The frequency of sanitization and the method used depends on your specific application. Sanitization can be done either continuously or periodically with shock treatments. Continuous sanitization keeps bacteria growth from recurring, while shock treatments remove bacteria but do not prevent it from recurring. Continuous sanitization is typically used when a constant level of sanitant is not harmful to the end-user production process. Shock treatments usually involve shutting down the production process, introducing sanitant into the system and then flushing the sanitant from the system before it is placed back on-line. Often, the water purification system must be cleaned before it can be sanitized. Cleaning removes the biofilm from equipment surfaces, resulting in more effective sanitization. Some common chemical sanitants are chlorine (liquid and gas), chloramines, chlorine dioxide (ClO2), hydrogen peroxide (H2O2), peracetic acid (CH3COOOH), ozone (O3) and formaldehyde (HCHO). Physical treatments include heat and ultraviolet (UV) light. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 15 WATER TREATMENT TECHNOLOGIES Ca+Mg+ SOFTENING Softening removes hardness minerals, such as calcium and magnesium from water. Water softeners are commonly used as pretreatment for boiler feed makeup water systems to prevent calcium and magnesium scale formation in boilers. They are also used to remove dissolved iron from water. Ion exchange water softening replaces or exchanges the calcium and magnesium cations with an equivalent number of sodium cations. Cation Resin Hot process softening removes hardness by heating the water to near boiling, Brine Tank followed by the introduction of softening chemicals, such as hydrated lime and soda ash. The minerals then precipitate and settle toward the bottom of the tank, forming a sludge blanket. As the treated water flows through the sludge blanket, most of the turbidity is trapped and removed. The effluent is then passed Na+ through filters that remove the last trace of suspended matter. Water Softening Cold lime softening is similar to hot process softening, except the water is not heated before lime is introduced into the system. This process is carried out in a specially designed clarifier. Softeners can be regenerated co-current (downflow) or counter-current (counterflow). Co-current is when the regenerant chemical and service flows are in the same direction. Counter-current is when the service and regeneration chemical flows are in the opposite direction. Counter-current operations provide lower hardness leakage when operated properly. ULTRAVIOLET STERILIZATION Ultraviolet (UV) sterilization is used as a pretreatment and/or post-treatment step to kill or inhibit growth of microorganisms, remove ozone, chlorine and trace organics and reduce total organic carbon (TOC). In UV sterilization, the water is exposed, at a controlled rate, to ultraviolet light waves. Ultraviolet is the band of light located in the spectrum between 2000 and 3000 Ångström wavelengths. The most effective range for destroying bacteria is at 2537 Ångström (254 nanometers). The bacteria absorb the UV radiation energy, which destroys or inactivates their DNA, thus preventing the bacteria from reproducing. UV systems may reduce 99% of bacteria in the water. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents BACK BACK Main Table of Contents Section Table of Contents 17 Products TA B L E O F CONTENTS BACK ACTIVATED CARBON FILTERS KF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 VP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 CT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 HOT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 ACTIVATED CARBON MEDIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 ANALYTICAL ANALYZERS, TEST KITS, SAMPLING DEVICES Analyzers Silica . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Chlorine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Hardness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Dissolved Solids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Hydrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Microbiological Analysis Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Portable TOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Test Kits Fouling Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Alkalinity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Carbon Dioxide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Chlorine. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Hardness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Iron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 pH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Silica . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 RO Water Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Sampling Devices Bacteria Samplers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 ESP Sanitary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 BAG FILTERS Filter Bags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 CARTRIDGE FILTERS Cartridge End Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Activated Carbon Filters Granular Activated Carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Pulverized Activated Carbon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Particulate Cartridges DI Gard™ String Wound. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 ROGARD™ Graded Density Polypropylene . . . . . . . . . . . . . . . . . . . 36 Prepure DP™ Graded Density Polypropylene Depth . . . . . . . . . . . . . 37 NT Series Graded Pore Polypropylene Depth. . . . . . . . . . . . . . . . . . . 38 Postpure PP™ Graded Density Pleated Polypropylene Depth . . . . . 39 NA Series Absolute Rated Polypropylene Depth. . . . . . . . . . . . . . . . . 40 WN Series Pleated Polysulfone Membrane. . . . . . . . . . . . . . . . . . . . . 41 Main Table of Contents 18 Products, continued WE Series Pleated Polysulfone Membrane . . . . . . . . . . . . . . . . . . . . 42 DI Series Pleated Hydrophilic PVDF Media . . . . . . . . . . . . . . . . . . . . 43 PV Series Pleated Hydrophilic PVDF Media . . . . . . . . . . . . . . . . . . . . 44 VH Series Pleated PES Media Pharmaceutical Grade. . . . . . . . . . . . 45 UF Series Hollow Fiber Polysulfone Media . . . . . . . . . . . . . . . . . . . . . 46 Housings 316 Stainless Steel, Single Tube (Code F) . . . . . . . . . . . . . . . . . . . . . 47 316L Stainless Steel, Single Tube (Code O) . . . . . . . . . . . . . . . . . . . . 48 316L Electropolished Stainless Steel, Multi-tube. . . . . . . . . . . . . . . . . 49 316L Stainless Steel, Multi-tube (High-Purity) . . . . . . . . . . . . . . . . . . . 50 316 Stainless Steel, Multi-tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 304 Stainless Steel, Multi-tube (with V Clamp closure). . . . . . . . . . . . 53 304 Stainless Steel, Multi-tube (with Swing Bolt closure). . . . . . . . . . . . 54 Polypropylene Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 White Polypropylene Plastic (Dialysis). . . . . . . . . . . . . . . . . . . . . . . . . 56 Natural Polypropylene Plastic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Speciality Cartridges CLERIFY™ Oil Adsorption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Vent Filter Cartridges Hydrophobic PTFE Media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 EA Series Hydrophobic Polypropylene Media . . . . . . . . . . . . . . . . . . . 60 VA Series Hydrophobic PTFE Media . . . . . . . . . . . . . . . . . . . . . . . . . . 61 VP Series Hydrophobic PTFE Media . . . . . . . . . . . . . . . . . . . . . . . . . . 62 CHEMICAL FEED SYSTEMS AND ACCESSORIES Pre-Kitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Dual Pump Skidded - Grundfos . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Dual Pump Skidded - LMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Polymer Feed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Metering Pumps Chem-Tech® Metering Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 LMI® Metering Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Pulsatron® Metering Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Pulsatron® Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Chem-Ad® LX Diaphram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Encore® 700 Diaphram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Chemtube® PPS Peristaltic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Instrumentation & Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Storage and Bulk Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 CLARIFIERS Permutit® Package Precipitators . . . . . . . . . . . . . . . . . . . . . . . . . . 80 CLEAN-IN-PLACE SKIDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 CONTINUOUS DEIONIZATION SYSTEMS CDI-LX™ Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 CDI® Replacement Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 CONTROL PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 BACK DEAERATORS Permutit® SLH Dearating Heaters. . . . . . . . . . . . . . . . . . . . . . . . . . 85 DEGASIFIERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 DEIONIZATION Recirculating Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 VP Series Two Bed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 VP Series Mixed Bed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 VP Series Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 DIALYSIS (HEMODIALYSIS) Bicarbonate Mixing System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Med-RO® Reverse Osmosis Medical System – RX Series . . . . . . . . 92 GAUGES Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 HIGH PURITY WATER SYSTEMS PureFit® High Purity Water Treatment Systems . . . . . . . . . . . . . . . . 96 ION EXCHANGE RESINS AND FILTER MEDIA USF™ Ion Exchange Resins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Filter Media and Activated Carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Resin Cross Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 ION EXCHANGE WASTEWATER SYSTEMS . . . . . . . . . . . . . . . . . . . 102 Aquasaver Chemical Feed And Pump Skid. . . . . . . . . . . . . . . . . . . . 103 LABORATORY WATER PURIFICATION SYSTEMS Ultrapure Water Systems PURELAB® Ultra Water Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 PURELAB® Classic Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 PURELAB® UHQ Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 MODULAB® High Flow Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 General Grade Water Systems PURELAB® Option-S 7/15/30/60 Water Systems . . . . . . . . . . . . . . 110 PURELAB® Option-R 7/15/30/60 Systems . . . . . . . . . . . . . . . . . . . 112 PURELAB® Option-Q 7/15 Systems . . . . . . . . . . . . . . . . . . . . . . . . 114 Primary Grade Water Systems PURELAB® Prima 7/15/20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 PURELAB® Prima 30/60/90/120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Centra Packaged Central Water Systems . . . . . . . . . . . . . . . . . . . . . 120 Medica Water Systems for Clinical Analyzers MEDICA® S/R/D 7/15 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 MEDICA® Pro 30/60/120 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . 124 MEDICA® R-200 (High Volume) Systems . . . . . . . . . . . . . . . . . . . . 126 Deionization Systems Portable Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Disposable Deionization System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Recirculating Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 Modular Docking Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Storage Reservoirs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Accessories Carboys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 Faucets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Main Table of Contents Products, continued 19 TOTAL-CHECK™ 900 total organic carbon Monitor. . . . . . . . . . . . . 135 Remote Control Stations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Remote Dispense Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 Point-of-Use Capsule Filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 IWT® Filtration Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Replacement Cartridges Siemens, USFilter®, ELGA® Lab Water Systems . . . . . . . . . . . . . . 140 Millipore® Lab Water Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Barnstead® Lab Water Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 LEAK DETECTORS DI-SDI ALERT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 WLD Model 300A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 LIGHTS, QUALITY INDICATOR 5-Range Purity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Hy-Lite Water Quality Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 LIQUID LEVEL CONTROLS Tank Level Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 METERS Conductivity & Resistivity Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Total Organic Carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 MULTIMEDIA FILTERS AVGF® Gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 KF Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 VP Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 PUMPS, CENTRIFUGAL Multiple Stage Centrifugal/Victaulic Booster . . . . . . . . . . . . . . . . . . . 159 Multiple Stage Centrifugal/ANSI Flange Booster. . . . . . . . . . . . . . . . 160 Feedwater Booster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 REVERSE OSMOSIS MEMBRANES Replacement Membranes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 Siemens Proprietary Membranes for Obsolete Systems . . . . . . . . . 163 REVERSE OSMOSIS SYSTEMS Vantage™ MicRo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 Vantage™ M21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 Vantage™ M41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 Vantage™ M43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 Vantage™ M83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 Vantage™ M84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 Pharm 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 40 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Vantage M240 Two Pass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 Vantage M280 Two Pass. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 BevMAX™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 SERVICE DEIONIZATION (SDI) SDI Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 SOFTENERS KF Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 KF Series Twin Alternating Softeners. . . . . . . . . . . . . . . . . . . . . . . . . 186 KF Series Duplex Alternating Softeners. . . . . . . . . . . . . . . . . . . . . . . 187 BACK VP Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 STORAGE TANKS Polyethylene, Conical Bottom. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 Fiberglass, Dish-Bottom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Polyethylene, Flat Bottom. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 TerraPure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 SYSTEM, EPV™ VALIDATABLE SKIDDED EPV™ Validatable Skidded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 SYSTEM, PreVUE® AND APEX™ VALIDATED SKIDDED PreVUE® Validated Skidded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 APEX™ Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 TEMPORARY MOBILE WATER TREATMENT Mobile Demineralization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 Mobile Clarification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 Mobile Reverse Osmosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 PreFlex® Skid-Mounted Pretreatment Systems . . . . . . . . . . . . . . . . 202 FlexTrex® Skid-Mounted Deionization Systems . . . . . . . . . . . . . . . . 203 FlexRO® Skid-Mounted RO Systems . . . . . . . . . . . . . . . . . . . . . . . . 204 ULTRAVIOLET STERILIZERS ZCS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 ZHX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 ZCT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 Replacement UV Monitoring for Aquafine® Series UV . . . . . . . . . . . 208 Ultraviolet Light Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 VALVES/REGULATORS Blend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Pressure Relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 WASTEWATER CAPABILITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 SUPPORT SERVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 WATER QUALITY STANDARDS AND CONVERSIONS . . . . . . . . . . . 231 GLOSSARY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 TRADEMARK STATEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253 Main Table of Contents 20 ACTIVATED CARBON FILTERS KF Series Carbon Filters Flow Rates from 1 to 81 gpm KF Series Carbon Filters are ideal for commercial and light industrial filtration applications where the advantages of a lightweight, corrosive-resistant FRP pressure vessel and cost-effective top mounted valve are desirable. • For pharmaceutical, cosmetic, microelectronic, boiler feed, process water, laboratory applications and more • Tanks are blow-molded plastic, wrapped with high-strength fiberglass and contain epoxy resin for worry-free service • Dependable motorized control valve is included with each filter • Electromechanical timer allows automatic backwash • Pretreatment lock-out switch assembly is included to deactivate downstream equipment during backwash Requires field assembly SYSTEM SPECIFICATIONS Tank Size (D x H in) Pipe Size (in) Chlorine 10x40 1.0 12x52 1.0, 1.5 14x65 1.0, 1.5 16x65 1.0, 1.5 18x65 1.0, 1.5 21x62 1.5, 2.0 24x72 2.0 30x72 2.0 36x72 2.0 42x72 3.0 Electrical Requirements Organics Commercial* RO-Feed** Commercial* RO-Feed** Service Service Service Service Flow Flow Flow Flow Backwash Media Flow Vol (ft 3) Overall Shipping Dimensions Weight LxDxH (in) lb (kg) 6 gpm 4 gpm 2 gpm 2 gpm 8 gpm 2.0 12x12x63 140 (64) 12 gpm 8 gpm 4 gpm 4 gpm 14 gpm 4.0 16x16x76 310 (141) 3 gpm 9 gpm 15 gpm 18 gpm 24 gpm 45 gpm 60 gpm 2 gpm 6 gpm 10 gpm 12 gpm 16 gpm 30 gpm 40 gpm 1 gpm 3 gpm 5 gpm 6 gpm 8 gpm 15 gpm 20 gpm 1 gpm 3 gpm 5 gpm 5 gpm 10 gpm 18 gpm 1.0 3.0 5.0 10x10x50 14x14x76 18x18x76 100 (46) 210 (96) 400 (182) 6 gpm 24 gpm 6.0 21x21x74 530 (241) 15 gpm 50 gpm 15.0 30x30x96 1530 (694) 8 gpm 20 gpm 81 gpm 54 gpm 21 gpm 27 gpm ........... 110 V/1 ph/60 Hz – 10 watts 30 gpm 70 gpm 90 gpm 8.0 20.0 27.0 24x24x90 36x36x97 42x42x110 1190 (540) 1943 (882) 2000 (907) *Flow is based on 3.0 gpm/ft3 for chlorine removal. Flow is based on 1 gpm/ft3 for organic reduction. **Dechlorination flow is based on 2 gpm/ft3, and assumes inlet Cl2 < 3 ppm; outlet Cl2 ≤ 0.1 ppm; inlet turbidity < 5 NTU. Organic reduction flow is based on 1 gpm/ft3, and assumes inlet TOC ≤ 5 ppm as O2 consumed; inlet turbidity < 5 NTU. ORDERING INFORMATION Catalog Number: System Name . . . . . . . . . . . . . . . KFZCS XXX KFZCS F X Z F X 010, 012, 014, 016, 018, 021, Pressure Vessel Diameter (in inches). . . . . . . 024, 030, 036, 042 Pressure Vessel Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F = non-code, fiberglass Control Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X = NEMA 3R equivalent A = 1" Level of Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z = Stand alone B = 1.5" Backwash/Regeneration Initiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F = Timeclock, NEMA 3R equivalent C = 2" Inlet/Outlet Pipe Size † . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E = 3" Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X X = No Option To determine your catalog order number, replace the X with one of the numbered options below it. These filters are also available as duplex units. Please contact our Technical Support team for more information. †All sizes are not available with every tank size. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 21 ACTIVATED CARBON FILTERS VP Series Carbon Filters Flow Rates from 8 to 300 gpm VP Series Carbon Filters are a low cost, reliable and efficient way to purify water. These rugged, pre-engineered, pre-assembled units minimize installation and startup costs and are ideal for boiler feed, process water or rinse water applications. • VPEC denotes Non-ASME code vessels offered with express delivery • VPAC denotes ASME code vessel with stamp available • Simple design maximizes reliability and efficiency • 100 psig vessel rating offers added strength and integrity • Structural steel (seismic zone 4) legs provide rigid support of vessel for safety • Skid mounting with (seismic zone 4) structural steel beams for duplex systems • Backwash and regeneration controls are highly reliable • Optional metallic piping ensures long life and durability • Standard epoxy internal and external coating extend vessel life SYSTEM SPECIFICATIONS Model Number . . . . . . . . . . . . . . . . . . . . . . . Flow Rates Good . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Better . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Best . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Backwash Flow Rate . . . . . . . . . . . . . . . . . . Rinse Flow Rate . . . . . . . . . . . . . . . . . . . . . . Media (cubic feet) . . . . . . . . . . . . . . . . . . . . . System Dimensions* Pipe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . Column Size (D x H) inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H x W x D Simplex (Duplex) – inch . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shipping Weight lb. – Simplex (Duplex) . . . . . . . . . . . . . . . . kg – Simplex (Duplex) . . . . . . . . . . . . . . . . Operating Weight lb. – Simplex (Duplex) . . . . . . . . . . . . . . . . kg – Simplex (Duplex) . . . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . . . . . Model Number . . . . . . . . . . . . . . . . . . . . . . . Flow Rates Good . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Better . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Best . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Backwash Flow Rate . . . . . . . . . . . . . . . . . . Rinse Flow Rate . . . . . . . . . . . . . . . . . . . . . . Media (cubic feet) . . . . . . . . . . . . . . . . . . . . . System Dimensions* Pipe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . Column Size (D x H) inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H x W x D Simplex (Duplex) – inch . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shipping Weight lb. – Simplex (Duplex) . . . . . . . . . . . . . . . . kg – Simplex (Duplex) . . . . . . . . . . . . . . . . Operating Weight lb. – Simplex (Duplex) . . . . . . . . . . . . . . . . kg – Simplex (Duplex) . . . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . . . . . • Schedule 80 PVC piping enhances corrosion-resistance VPEC/VPAC-024 VPEC/VPAC-630 VPEC/VPAC-636 VPEC/VPAC-742 32 16 8 31 19 8 48 24 12 49 29 12 72 36 18 71 42 18 96 48 24 96 58 24 24 x 48 61x122 76x43x41 (80x97x41) 193x110x104(204x247x104) 30 x 60 77x153 90x43x48 (94x97x48) 229x110x122 (239x246x122) 36 x 60 92x153 96x45x54 (100x97x54) 244x114x137 (254x246x137) 42 x 72 107x183 112x47x58 (116x133x58) 285x119x147 (295x338x147) 1-1/2” 1,000 (2,000) 454 (908) 1-1/2” 1,380 (2,760) 626 (1,252) 2” 2,190 (4,380) 994 (1,987) 2” 3,160 (6,320) 1,433 (2,866) 1,800 (3,600) 2,580 (5,160) 4,340 (8,680) 6,090 (12,180) 817 (1,633) 1,171 (2,341) 1,969 (3,938) 2,762 (5,524) 110 V / 60 Hz / 1 ph / 3 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VPEC/VPAC-648 VPEC/VPAC-754 VPEC/VPAC-760 VPEC/VPAC-772 128 64 32 126 75 32 160 80 40 159 95 40 200 100 50 196 118 50 300** 150 75 283 170 75 48 x 60 122x153 106x54x65 (110x132x66) 269x137x165 (279x335x168) 54 x 72 139x183 121x61x75 (127x158x75) 307x155x191 (323x401x191) 60 x 72 153x183 125x64x81 (131x158x81) 318x163x206 (333x401x206) 72 x 72 183x183 129x72x93 (136x158x93) 328x183x236 (345x401x236) 2-1/2” 4,040 (8,080) 1,833 (3,666) 3” 5,550 (11,100) 2,517 (5,034) 3” 7,065 (14,130) 3,205 (6,410) 3” 10,210 (20,420) 4,631 (9,262) 7,940 (15,880) 10,570 (21,140) 13,275 (26,550) 19,200 (38,400) 3,602 (7,204) 4,794 (9,588) 6,021 (12,042) 8,709 (17,418) 110 V / 60 Hz / 1 ph / 3 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ORDERING INFORMATION VP Series Carbon Filters have extensive option packages. For ordering instructions, or additional product information, please contact technical support at 800.875.7873 extension 5000. * Approximate ** Rating for metallic piping only. Plastic piping requires aeration due to line velocities. Siemens In accordance with Siemens policy for continual product development and improvements, we reserve the right Water Technologies to change the product information within this literature at any time, without notice. Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 22 ACTIVATED CARBON FILTERS CT Series Carbon Towers Flow Rates from 57 to 382 gpm A complete line of standard carbon tower units designed for the beverage industry or any application that can utilize hot water or steam sanitization for dependable operation. The CT Series designation refers to beverage grade carbon towers with stainless steel pressure vessels, face piping and internal distributors. The units are available with programmable logic controllers (PLC) or manual operation. Carbon media and other optional equipment can be easily selected and ordered to address your specific requirements. • For pretreatment applications requiring removal of chlorine, chloramine, and many types of organic contaminants • Vessels are designed for hot water sanitization and steam vapor stripping/sanitization, bottom and/or top entry, for removing VOC’s such as trihalomethanes • Standard system is based on 1 gpm/ft3 and a backwash rate near 2 gpm/ft3 (dependent upon carbon density and particle size) • Uses advanced well screen internals to guarantee uniform distribution during draw-off and backwashing • Units available with PLC or manual operation • Vessels, piping and internals available in 316L or 304 stainless steel combinations • Full Drainability using scavenger screen ensures continuous complete removal of condensate during steaming • Higher flow systems, manway types, temperature and control probes, special carbon attributes, sampling ports, and finishes can be customized with minimal impact on delivery and cost SYSTEM SPECIFICATIONS Model Number CT050 CT100 CT150 CT200 CT250 CT300 CT350 Service Flow Rate . . . . . . . . . . . . . . . . . . 57 gpm 118 gpm 170 gpm 231 gpm 265 gpm 302 gpm 382 gpm Backwash Flow Rate*. . . . . . . . . . . . . . . . <96 gpm <196 gpm <283 gpm <385 gpm <442 gpm <503 <636 gpm Media Volume of Carbon (cu. ft.) . . . . . . . 57 118 170 231 265 302 382 Shell Diameter . . . . . . . . . . . . . . . . . . . . . 42" 60" 72" 84" 90" 96" 108" Carbon Bed Depth . . . . . . . . . . . . . . . . . . >5’ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Freeboard Above Carbon . . . . . . . . . . . . . >50% . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Design Pressure . . . . . . . . . . . . . . . . . . . . 65 or 100 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . Automated (PLC) or Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Underdrain System. . . . . . . . . . . . . . . . . . Well Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manway . . . . . . . . . . . . . . . . . . . . . . . . . . Top. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . 120 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . *At 10 gpm/ft2 and depends on carbon density and particle size. ORDERING INFORMATION Catalog Number: CT 050 System Name . . . . . . . . . . . . . CT 050, 100, 150, Model Number . . . . . . . . . . . 200, 250, 300, 350 A 6 6 A A = 100 psi Design Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B = 65 psi 6 = 316L Vessel Vessel Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 = 304 Vessel Piping Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 = 304 Piping Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 = 316L Piping A = Automatic Operation M = Manual Operation In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 23 ACTIVATED CARBON FILTERS Heat Optimized Technology “HOT” Series Systems for Carbon Towers For use with new or existing carbon towers Bacteria in production water and biofouling of water treatment systems can create operational challenges for Beverage and BioPharm manufacturers. To meet these challenges, the “HOT” Series systems were introduced. HOT technology is a Siemens patented process that provides thorough sanitization of new or existing carbon towers, reduces backwash water by up to 75%, and adds process control. HOT Series systems use hot water to eliminate the potential for bed contamination that can exist from utilizing plant steam. A HOT Series system can be provided independently, with or without an optional chilling exchanger, or as a complete system including carbon towers and ancillary equipment. • Field proven to provide more effective microbial kill than conventional steaming processes • More thorough kill lessens the bacteria counts, to significantly increase periods between sanitizations • Available with fully automated or manual operation • All stainless steel skid and process piping • Fully wired and hydrostatically tested prior to shipment • Less biofouling and cleaner carbon significantly increase carbon performance and substantially reduce costs • The heating system is capable of sanitizing the loop distribution piping and polishing equipment for improved operations • Bacteria control is improved due to uniform heating of the carbon bed in the expanded state with reduced potential for cold spots during sanitization. Time Comparison Of Heat Sanitization Techniques Within A Single 84” Diameter Carbon Tower Backwash to Drain (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Backwash Recycle & Heat (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . Heat-Up (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hold Time (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cool Down (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rinse to Drain (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Total Time (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Hours) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operator Attention (Hours) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Total Water Used (Gallons) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conventional Steaming HOT Series Systems 20 — 240 30 – 60 480 5 805 13.4 3 13,800 5 60 — — 480 5 550 9.2 0.5 4,500 HOT Series with Optional Chilling Exchanger 5 60 — 15 – 30 60 5 160 2.2 0.5 4,500 Beverage manufacturers who have extremely low bacteria specifications are utilizing loop configuration water distribution systems to keep the water moving more effectively than “dead ended” systems. The heating system included with the HOT Series Systems can serve double duty by sanitizing the loop distribution piping and polishing equipment as well. ORDERING INFORMATION Catalog No.: 67/HOT 250 T Heat Optimized Technology System . . . . . . 67/HOT Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 - Backwash: 96–283 GPM (For Siemens CT050, CT100, and CT150) 250 - Backwash: 284– 442 GPM (For Siemens CT200 and CT250) T - SS Tubing with Threads, 350 - Backwash: 443–636 GPM Flanges and Tri-clamps (For Siemens CT300 and CT350) S - SS Tubing with Tri-clamps Piping Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . only, 180 grit ID polish 2 - 208/240 VAC, 3 Phase, 60 Hz Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 480 VAC, 3 phase, 60 Hz Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A A - Automatic Cooling Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C C - Cooling Exchanger Included N - No Cooling Exchanger Valve Kits: For integration of the HOT Series System with existing 5 valve carbon towers, 2 additional valves are necessary for proper interconnection. The part numbers below are for a kit of 2 valves. Order 1 kit for each existing carbon tower that the HOT System will be used with. It is critical to consider the HOT Series System must work in conjunction with either a new or an existing carbon tower that is rated for a minimum of 65 PSI and equipped with ASME pressure relief valves. The HOT Series is intended for applications with both new or existing carbon towers. The backwash flow rates and pump sizing of the HOT Series system are based on the CT Series carbon towers. Some older, existing carbon towers utilize a 2’ bed depth or a wider, stockier vessel. This would change the required flow rates of the backwash and sanitization steps of the HOT process. HOT Series systems can be incorporated with Siemens either style of carbon tower. A Siemens Applications Engineer will ensure the HOT Series system is sized correctly for retrofit vessels. Water Technologies In accordance with Siemens policy for continual product development and improvements, we reserve the right Technical Support 800.875.7873 ext. 5000 to change the product information within this literature at any time, without notice. BACK Section Table of Contents 24 ACTIVATED CARBON MEDIA Activated Carbon Media Siemens Water Technologies is a national provider of complete turnkey carbon services. We inventory a full line of premium Westates® activated carbons made from high quality bituminous coal, coconut shell and anthracite coal raw materials. Applications for activated carbon include improving the taste and quality of drinking water, treating industrial wastewater, purifying materials used in production processes, controlling air emissions, and filtering contaminants out of groundwater in environmental cleanup sites. Our laboratory analyzes and certifies the quality of all the activated carbon supplied through an extensive QA/QC program. Our strategically located service centers allow for efficient and prompt delivery and service. Applications • Chlorine removal • Chloramine removal • VOC control from air strippers, soil vapor extraction and air sparge systems • Remediation • Solvent Recovery • Odor Control • Trace Organics • Disinfection By-products Westates® Activated Carbon Products • Vapor Phase Carbons • Liquid Phase Carbons • Bulk Carbons • Coconut-Shell Carbons • Bituminous Coal Carbons • Impregnated Carbons • Anthracite Carbons • Midas® Odor Control Media • VoCarb® Carbon • AquaCarb® Carbon Midas® Odor Control Media (OCM) Midas® OCM is a breakthrough in odor control. Unlike any other odor control media, Midas OCM is manufactured in a special process combining selected active ingredients and premium quality bituminous coal to produce an extraordinarily high H2S breakthrough capacity. This odor control media is not impregnated and therefore does not suffer the serious drawbacks associated with alkali-impregnated carbons. The lack of impregnant means all of Midas OCM’s pore volume and surface area are available for storing the sulfur produced during the catalytic oxidation of H2S and for the adsorption of any VOCs that may be present in the gas stream. And, since Midas OCM is not impregnated, it is safer to load, start-up and remove from an adsorber system. For a complete list of our Activated Carbon Turnkey Services, see page 216. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents ANALYTICAL TEST KITS, ANALYZERS, SAMPLING DEVICES Analyzers, Test Kits, Sampling Devices ORDERING INFORMATION Catalog No. Description ZWRQ03275 Fouling Index Test Kit METCL4678002 Chlorine Analyzer METSI6000001 HDREGTKIT METCDML532T1 METHY0828720 MHWG 037 00 ZTOCA1S20P METHD4270002 Silica Analyzer Hardness Monitor Replacement Reagent Kit Dissolved Solids Meter Dual Scale Universal Hydrometer Microbiological Analysis Monitor, white grid 50/pk Anatel® A1000 S20P Portable TOC Meter Hach® Hardness Monitor FOULING INDEX TEST KIT (SILT DENSITY INDEX) Used to measure the amount of colloidal particulate matter in a water stream, includes a filter disc holder, pressure regulator, pressure gauge, tweezers, filter discs, valves and fittings. Also required, but not included, is a timing device (stop watch, or wrist watch with a second hand). Measurement is made by passing the stream of water at a constant pressure through the filtration disc for a predetermined amount of time. SILICA ANALYZER Fully automated, continuous silica monitor measures silica in a single stream of water in the 0-100 ppb range. The monitor uses a silica molybate colorimetric procedure to measure resistive silica. Sulfuric acid and ammonium molybdate are added to the water sample, forming molybdosilica acid. Oxalic acid is used to reduce the molybdosilica acid to a molybdenum blue complex, which is measured photometrically at 810 nm. The silica analyzer requires 115V AC for operation, and comes with a one month supply of all necessary reagents, calibration solutions, and replacement tubing harness. CHLORINE ANALYZER Designed to provide an alarm signal when the total available chlorine in a water sample exceeds a preset limit. Has a 0.5 mg/L range, 0.01 mg/L resolution, and automatic color/turbidity compensation. Uses the DPD colorimetric method to measure free chlorine. HARDNESS MONITOR Designed to provided an alarm signal when the total hardness in the water sample exceeds a preset limit. The alarm trip point for this detector is 2 mg/L. The unit performs an analysis every two minutes. The hardness monitor uses a buffered colorimetric indicator to detect total hardness. A color is developed following the addition of an indicator reagent and a buffer in precise proportions. Color development is monitored by a colorimetric photometer. Three consecutive “hard” indications are required before an alarm circuit is activated; two before the alarm is cancelled. All reagents are included in the initial kit. DISSOLVED SOLIDS METER Hand-held analog meter measures three ranges of dissolved solids (0-50, 0-500 and 0-5000 ppm) and features automatic temperature compensation, and a built-in cell cup that contains self-maintaining electrodes that never need replatinizing. DUAL SCALE UNIVERSAL HYDROMETER Measures the density of liquids both lighter and heavier than water. This plain form hydrometer is 15" (38cm) long, with a specific gravity range of 0.700 to 2.00 (Baume 10 to 70° light, 0 to 70° heavy). MICROBIOLOGICAL ANALYSIS MONITORS, 37mm Two-piece disposable monitor for microbiological analysis of samples by either vacuum filtration or for use with an ESP sampling valve. The 0.45 mm pore size filter is grid marked to aid in counting colonies grown on the surface. ANATEL® A1000 S20P PORTABLE TOC METER Rugged unit combines a sensor with controller, printer and carrying handle for convenient portability within your water system. This unit provides TOC analysis to 0.05 ppb without the inconvenience of acids, oxidants, and gases. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 25 26 ANALYTICAL TEST KITS, ANALYZERS, SAMPLING DEVICES Analyzers, Test Kits, Sampling Devices ALKALINITY Use a drop count titration method for the measurement of carbonates, bicarbonates, hydroxides, and other dissolved salts. In this kit an indicator is added to the sample, and then a dropper is used to add the titrant until the color changes. Kit includes enough reagents to perform approximately 100 phenolphthalein and 100 total (as CaCO3) tests. CARBON DIOXIDE Use a drop count titration method for the measurement of carbon dioxide. An indicator is added to the sample, and then a dropper is used to add the titrant until the color changes. Kit includes enough reagents to perform approximately 200 tests. CHLORINE - LOW RANGE Use a color disk that features a continuous-gradient color wheel for fast, accurate comparisons for chlorine measurement. The color wheel is simply rotated to obtain a color match with the treated sample. Each kit includes enough reagents to perform approximately 100 tests. CHLORINE - MID AND HIGH RANGE Use a drop count titration method to measure chlorine. An indicator is added to the sample, and then a dropper is used to add the titrant until the color changes. Kit measures total chlorine in the range of 10-200 mg/L. Kit includes enough reagents to perform approximately 100 tests. HARDNESS Use a drop count titration method for the measurement of calcium and magnesium. An indicator is added to the sample, and then a dropper is used to add the titrant until the color changes. Kit measures total hardness at CaCO3 in the range of 1-20 mg/L. Kit includes enough reagents to perform approximately 100 tests. IRON Use a color disk that features a continuous-gradient color wheel for fast, accurate comparisons for iron measurement. The color wheel is simply rotated to obtain a color match with the treated sample. Kit measures Fe in the range of 0-5 mg/L. Each kit includes enough reagents to perform approximately 100 tests. pH Most natural waters range from pH 4 to pH 9. Uses a color disk that features a continuous-gradient color wheel for fast, accurate comparisons. The color wheel is simply rotated to obtain a color match with the treated sample. Kit measures pH in the range of 4-10. Each kit includes enough reagents to perform approximately 300 tests. SILICA-LOW RANGE Uses a color disk that features a continuous-gradient color wheel for fast, accurate comparisons. The color wheel is simply rotated to obtain a color match with the treated sample. Kit measures SiO2 in the range of 0-1 mg/L. Each kit includes enough reagents to perform approximately 100 tests. ORDERING INFORMATION Catalog No. Description KIT2444301 Alkalinity Test Kit REAG2437401 Replacement reagent set (approx. 100 tests) KIT143601 Carbon Dioxide Test Kit REAG2437500 Replacement reagent set (approx. 200 tests) KIT1454201 KIT1454202 KIT1454200 Chlorine-Low Range, as free Cl2 down to 0.2 mg/L Chlorine-Low Range, as total Cl2 down to 0.2 mg/L Chlorine-Low Range, as free and total Cl2 down to 0.02 ppm mg/L REAG1406499 Replacement reagent set total chlorine REAG1407099 Replacement reagent set free chlorine REAG2440400 Replacement reagent set free & total chlorine KIT2444400 Chlorine-Mid and High Range Test Kit REAG2437700 Replacement reagent set (approx. 100 tests) KIT145201 Hardness Test Kit REAG2437800 Replacement reagent set (approx. 100 tests) KIT146400 REAG92799 Iron Test Kit Replacement reagent set (approx. 100 tests) KIT147011 pH Test Kit REAG2329332 Replacement reagent set (approx. 300 tests) KIT2255000 Silica-Low Range Test Kit REAG2462200 Replacement reagent set (approx. 100 tests) KIT1455400 Silica-High Range Test Kit REAG2462300 Replacement reagent set (approx. 100 tests) HAWP04700 TESTKITUP Replacement filters for Fouling Index Test Kit RO Water Quality Test Kit SILICA-HIGH RANGE Uses a color disk that features a continuous-gradient color wheel for fast, accurate comparisons. The color wheel is simply rotated to obtain a color match with the treated sample. Kit measures SiO2 in the range of 0-40 mg/L. Each kit includes enough reagents to perform approximately 100 tests. RO WATER QUALITY TEST KIT Convenient, self-contained test kit provides all the materials and instructions required for on-site monitoring of reverse osmosis (RO) systems, for both feed and product water. Because tap water is checked, pretreatment components for optimum RO performance can be determined. Each kit contains all materials and instructions to perform the following tests: Silt Density Index, Total Hardness, Alkalinity, pH, Temperature, Langelier Saturation Index, Free and Total Chlorine, Soluble and Insoluble Iron, Carbon Dioxide and Silica. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents ANALYTICAL TEST KITS, ANALYZERS, SAMPLING DEVICES Bacteria Samplers Provides simple, fast microbiological analysis of surface, natural source, make-up, process and laboratory-grade water (or high-purity). Extremely versatile for sampling fluids and different types of surfaces and crevices. Can be used in a variety of industries including beverage bottling/canning, cosmetic and pharmaceutical manufacturing, food processing. Each sampler absorbs 1 mL of sample. Consists of a plastic tab supporting a 0.45 µm filter bonded to an adsorbent pad containing dehydrated nutrient medium, and all contained in a transparent plastic case. • Filter surface is grid-marked to permit counting colonies • Presterilized and ready for use, the sample does not require special preparation • Entire assembly is sterilized and packaged in a sealed plastic envelope. Samples may be used in conjunction with the swabbing unit for surface-sanitization. This is a cotton-tipped swab stick in sterile buffer contained in a vial similar to the sampler vial. ORDERING INFORMATION Catalog No. MC0010025. . . . . MY0010025. . . . . MT0010025. . . . . MHPC10025 . . . . B01040WA . . . . . Description Coli-count Sampler (blue) 25/pk Yeast and Mold Sampler (white) 25/pk Total Count Sampler (white) 25/pk HPC Total Count Sampler for Dialysis (red) 25/pk Whirl-Pak® Thio-Bag® 100mL (100/pk) Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 27 28 ANALYTICAL TEST KITS, ANALYZERS, SAMPLING DEVICES ESP Sanitary Sampling Valves The ESP sanitary sampling valve is designed for the sterile sampling of high-purity water. It allows for mid-stream sample collection in water lines, resulting in truly representative sampling. The unique design eliminates bacterial and particle build-up that could interfere with bacteriological test results. • Comes complete with two 18-gauge blunt-end syringe needles (for sanitization), a spare set of seals, and two sealing caps (covers the Luer-slip outlet to maintain sanitary conditions) • Available in 1/4" (for use with 1-1/2" or larger diameter lines) and 1/8" (for use with 3/4" or larger lines) NPT or weldable configurations • Valves pre-welded into 1" – 3" diameter spool pieces or a 1-1/2" TC end cap is also available • Easily installed in liquid distribution lines; can be kept in a sanitary condition between uses • Bacteriological analysis monitor can be directly attached to the valves Luer-slip outlet, or flow can be directed into any type of container • Sampling valve body and stems constructed of 316 stainless steel • Operational up to 100 psig (7 bar) at 25°C SYSTEM SPECIFICATIONS Catalog Number ZWSSP0400 Type 1/4" NPTM Spare Parts Whirl-Pak® Bags (100 mL; 100/pk) Plastic Syringes, 20 mL (12/pk). Plastic Syringes, 50 mL (5/pk). . Spare Parts Kit (3 Viton® o-rings, 5 syringe needles, 10 plastic caps, 3 plug seals) Plastic Cap Only . . . . . . . . . . . . Spare Parts Kit (2 o-rings, 2 plug seals) . . ZWSSP0800 ZWSSPW400 1/8" NPTM Catalog No. 1/4" weldable ZWSSPW800 1/8" weldable ZWSSPW840 1" pre-welded ZWSSPW441 1 1/ 2" pre-welded ZWSSPW442 TC 2" pre-welded ZWSSPW442 9594 TC 3" pre-welded TC end cap pre-welded B01040WA XX11 020 12 XX11 050 05 YY20 04K 00 P91018 P91968 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 29 BAG FILTERS Bag Filters BAG FILTERS (LOW FLOW) • Polypropylene thermally welded bag ORDERING INFORMATION ORDERING INFORMATION Size Size LOW FLOW 20” LOW FLOW 10” 10 10 10 10 10 10 10 Micron Catalog Number 1 5 10 25 50 100 200 Micron Catalog Number 20 20 20 20 20 20 20 D1004445 D1004447 D1004449 D1004451 D1004453 D1004455 D1004457 1 5 10 25 50 100 200 D1004446 D1004448 D1004450 D1004452 D1004454 D1004456 D1004458 BAG FILTERS • Available in #1 (7x16.5") and #2 (7x32") sizes • Stainless steel locking ring • Choice of polypropylene or polyester felt materials ORDERING INFORMATION Polypropylene Felt Size Micron P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . 1 5 10 25 50 100 P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . 1 5 10 25 50 100 Catalog Number FBWPO1P2S FBWPO5P2S FBWPO10P2S FBWPO25P2S FBWPO50P2S FBWPO100P2S FBWPO1P1S FBWPO5P1S FBWPO10P1S FBWPO25P1S FBWPO50P1S FBWPO100P1S Polyester Felt Size P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . Micron Catalog Number 1 5 10 25 50 100 1 5 10 25 50 100 FBWPE1P2S FBWPE5P2S FBWPE10P2S FBWPE25P2S FBWPE50P2S FBWPE100P2S FBWPE1P1S FBWPE5P1S FBWPE10P1S FBWPE25P1S FBWPE50P1S FBWPE100P1S BAG FILTERS (SEWN-CASE QUANTITIES ONLY) • Polypropylene or polyester ORDERING INFORMATION ORDERING INFORMATION Size Micron Catalog Number Size Micron 5 10 25 50 100 P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . 5 10 25 50 100 Polypropylene P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . P1 . . . . . 5 10 25 50 100 FBSP05P2P FBSP010P2P FBSP025P2P FBSP050P2P FBSP0100P2P FBSP05P1P FBSP010P1P FBSP025P1P FBSP050P1P FBSP0100P1P Polyester P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . P2 . . . . . 5 10 25 50 100 Catalog Number FBSPE5P2S FBSPE10P2S FBSPE25P2S FBSPE50P2S FBSPE100P2S FBSPE5P1S FBSPE10P1S FBSPE25P1S FBSPE50P1S FBSPE100P1S Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 30 BAG FILTERS Bag Filter Housings STAINLESS STEEL NON-CODE BAG FILTER HOUSINGS* • 316SS construction • BUNA-N O-ring • 2" NPTF threaded or 2” RF 150lb ANSI flanged • Available in 65 gpm (size P1) or 125 gpm (size P2) flow rates • Rated at 150 psi @ 200°F ORDERING INFORMATION P1 . . . . . . . . . P2 . . . . . . . . . P1 (Flng). . . . P2 (Flng). . . . Catalog Number: FBHFBF111S FBHFBF112S FBHFBF111SF FBHFBF112SF STAINLESS STEEL ASME CODE BAG FILTER HOUSINGS* • 316SS construction • BUNA-A O-ring • RF 150lb ANSI flanged connections • Single bag housings available with swing bolt closure • Multi bag housings have swing bolt spring-assist closure, see flow rates below • Rated at 150 PSI @ 200˚F ORDERING INFORMATION 1 bag . . . . . . . . . . 1 bag . . . . . . . . . . 3 bag . . . . . . . . . . 4 bag . . . . . . . . . . 6 bag . . . . . . . . . . 8 bag . . . . . . . . . . Size Flow Rate Connection Part Number P2 125 2” FBHTBF112S 400 4” FBHF3AV0400001 P1 P2 P2 P2 P2 65 230 2” 3” 675 6” 900 8” FBHTBF111S FBHF3AV0300001 FBHF3AV0600001 FBHF3AV0800001 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 31 BAG FILTERS Bag Filter Housings PLASTIC BAG FILTER HOUSINGS (STANDARD FLOW) • Heavy duty reinforced polypropylene construction • Viton® Seals • 2" NPTF connections • Available in 50 gpm (size P1) or 100 gpm (size P2) flow rates • Rated at 150 psi @ 80°F • Duplex valved A/B bank divert operation ORDERING INFORMATION P1 . . . . . . . . . P2 . . . . . . . . . P1 (duplex) . . P2 (duplex) . . Catalog Number: FBHFLT4201 FBHFLT4202 FBHFLT1DUP FBHFLT2DUP PLASTIC BAG FILTER HOUSINGS • Polypropylene construction • Choice of 10” or 20” housings • Comes with gauge, wrench and 3/8” drain valve • Available in 1” and 1 1/2” NPT sizes • Large Acme thread closure ORDERING INFORMATION 10" . . . . . . . . . . . 10" . . . . . . . . . . . 20" . . . . . . . . . . . 20" . . . . . . . . . . . Inlet/Outlet Flow Rate Part# 1.5" 20 GPM D1004443 1" 1" 1.5" 15 GPM 15 GPM 20 GPM D1004442 FC150367 D1004444 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 32 CARTRIDGE FILTERS Cartridge End Caps The following table is presented as reference when ordering filter cartridges. For more detailed information, please contact our Technical Support Team at 800-8757873 ext. 5000. CARTRIDGE DESIGN DESCRIPTION Code F Style Cartridges Double open end with flat gasket Code 10 Style Cartridges Single Open End with 1-120 Internal O-Ring at Open End Code O Style Cartridges Single Open End with 2-222 O-Ring with Seal Code 5 Style Cartridges Single Open End 2-222 O-Ring Seal and Spear End Assembly Code 7 Style Cartridges Single Open End with 2-226 O-Ring Locking Seal and Spear End Assembly Code K SOE plastic spring assembly, saw cut end Gaskets compressed on knife edge seal of housing Single O-ring located inside the cartridge CODE F 10 O-rings are located externally on the cartridge 0 O-rings are located externally on the cartridge 5 O-rings are located externally on the cartridge. The adapter 7 locks into the housing with spear assembly Knife edge SOE with spring seal K Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 33 CARTRIDGE FILTER - ACTIVATED CARBON Granular Activated Carbon Filter Cartridge • Composed of lignite-based granular activated carbon in an upflow cartridge design for removing chlorine feed water • Cartridge is designed to allow water to enter the bottom of the cartridge, then filtered through the entire carbon bed before exiting at the top to maximize the contact time and therefore the adsorption • Internal expansion pad maintains a tight, compact column to minimize channeling or bypass • Nominal 20 micron post-filter reduces carbon fines as well as other suspended particles SPECIFICATIONS Dimensions 10" Cartridge 20" Cartridge Diameter (OD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Length (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.875" (7.3 cm) 9.75" (24.8 cm) 2.875" (7.3 cm) 20" (50.8 cm) 10" Cartridge Maximum . . . . . . . . . . . . . . . . . . . . . 1.0 gpm (3.8 lpm) 2.0 gpm (7.6 lpm) Filter Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Post filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Expansion Pad Foam . . . . . . . . . . . . . . . . . . . . . . . Outer Casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . End Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Granular, Activated Carbon Spun Polypropylene Polyether/Polyurethane Polystyrene Polystyrene Buna-N Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . 32 to 125°F (0 – 52°C) Recommended Water Flow Rates Materials Operating Parameters Carbon Volume . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ounces of granular carbon per 10" length ORDERING INFORMATION Catalog Number Description FCGC . . . . . . . . . . . . . Filter cartridge granular carbon XX . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20 F................. 20 . . . . . . . . . . . . . . . . Cartridge Code: F = flat gasket seal Nominal micron retention rating To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 34 CARTRIDGE FILTER - ACTIVATED CARBON Pulverized Activated Carbon Filter Cartridge • Composed of pre-washed, finely pulverized activated carbon, encapsulated in a depth filtration media of highly purified alpha-cellulose and synthetic fibers for removing chlorine • Depth-type cartridge ensures superior dirt holding capacity in sediment-laden waters to minimize premature exhaustion while it is being carbon treated • Design includes a thermally bonded outer, nominal 10 micron pre-filtration layer that provides for depth filtration in one pass without carbon channeling or media migration SPECIFICATIONS Dimensions 10" Cartridge 20" Cartridge Maximum . . . . . . . . . . . 1.0 gpm (3.8 lpm) 2.0 gpm (7.6 lpm) Primary filter media . . . . . . . . . . . . . . . . Inner Layer Media . . . . . . . . . . . . . . . . . Inner Core . . . . . . . . . . . . . . . . . . . . . . . Outer Netting . . . . . . . . . . . . . . . . . . . . . End Caps. . . . . . . . . . . . . . . . . . . . . . . . Pulverized, Activated Carbon Alpha Cellulose and Synthetic Fibers Polypropylene Polyolefin Low Durometer Polyethylene Temperature Range . . . 32 to 125°F (0 – 52°C) Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.75" (7.0 cm) 9.75" (24.8 cm) Recommended Water Flow Rates Materials Operating Parameters Carbon Volume ................... 2.75" (7.0 cm) 20" (50.8 cm) 3.7 ounces of pulverized carbon per 10" length ORDERING INFORMATION Catalog Number Description FCPC . . . . . . . . . . . . . . Filter cartridge pulverized carbon F . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20 10 . . . . . . . . . . . . . . . . . Nominal micron retention rating To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 35 CARTRIDGE FILTER - PARTICULATE DI GARD™ String Wound Prefiltration Cartridges • Designed for a variety of prefiltration applications such as SDI (service deionization), reverse osmosis, and CDI® (Continuous Deionization) systems • String wound type filter with your choice of cotton, industrial or surfactant-free polypropylene string over a polypropylene core • Large void volume design for low-cost, reliable filtration performance with high contaminant holding capacity • Continuous filter winding in 20-, 30-, and 40-inch lengths prevents by-passing or excessive pressure drops at the seams • Gasketed end caps on 0.5 µm rated filters for positive sealing that eliminates by-passing • Surfactant-free FCPX style filter meets USP Class VI Biological Tests for Plastics requirements SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.5" (6.5 cm) 9.75, 10, 19.5, 20, 29.25, 30, 40 FCCS . . . . . . . . . . . . . . FDA-Listed bleached white cotton fiber string media with polypropylene core FDA-Listed polypropylene fiber string media with polypropylene core Surfactant-free polypropylene fiber string media with polypropylene core NOTE: Code F cartridges (0.5 µm) have santophrene end seals. Materials FCPS . . . . . . . . . . . . . . FCPX . . . . . . . . . . . . . . ................... Operating Parameters Maximum Temperature . . . . . . . . . . . . . Maximum Differential Pressure @ 25°C Micron Ratings. . . . . . . . . . . . . . . . . . . . Filtration Efficiency . . . . . . . . . . . . . . . . Recommended Water Flow Rates . . 140°F (60°C) 50 psi (3.4 bar) 0.5, 1, 3, 5, 10, 20, 50 Microns Nominal 90% 5.0 gpm/10" length (18.9 lpm/10" length) ORDERING INFORMATION Catalog Number Description FCXX . . . . . . . . . . . . . . FCCS = FDA-Listed bleached cotton string fiber FCPS = FDA-Listed polypropylene string fiber FCPX = surfactant-free polypropylene string fiber cartridge F . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 19 = 19.5, 20 = 20, 29 = 29.25, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 20 = 20 µm, 50 = 50 µm To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 36 CARTRIDGE FILTER - PARTICULATE ROGARD™ Graded Density Polypropylene Media Filter Cartridge • Designed for a variety of prefiltration applications such as SDI (service deionization), reverse osmosis and CDI® (Continuous Deionization) systems • Graded density melt spun polypropylene media design for exceptional throughput, with high contaminant holding capacity • Gasketed end caps on 1, 3 and 5 µm rated filters for positive sealing that eliminates bypass contamination • Manufactured from materials which are listed for food contact applications in Title 21 of the U.S. Code of Federal Regulations. Product in compliance with EU Directive 2002/72/EC for plastic in food contact (in simulants A, B, C, and D). • All polypropylene components meet the specifications for biological safety as per the USP for Class VI-121˚C plastics (gaskets/O-rings excluded). • FCRO Series filter cartridges are free of surfactants, anti-static agents, binders, and adhesives • NSF Certified SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.5" (6.5 cm) 9.75, 10, 12, 19.5, 20, 30, 31, 40 Media . . . . . . . . . . . . . . Core . . . . . . . . . . . . . . . O-Rings. . . . . . . . . . . . . Gaskets. . . . . . . . . . . . . Melt blown polypropylene Integral polypropylene core Silicone o-rings Santoprene end seals Maximum Temperature . . . . . . . . . . . . . Maximum Differential Pressure @ 25°C Micron Ratings. . . . . . . . . . . . . . . . . . . . Filtration Efficiency . . . . . . . . . . . . . . . . Recommended Water Flow Rate . . . 140°F @ 25 psid 50 psi (3.4 bar) 1, 3, 5, 10, 20, 25, 50, 75 microns Nominal 90% 5.0 gpm/10" length (18.9 lpm/10" length) Materials Operating Parameters ORDERING INFORMATION Catalog Number and Description FCRO . . . . . . . . . . . . . . Rogard II all polypropylene depth cartridge X . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end (1&5 µm w/gasket) K = knife edge seal with spring seal 0 = 2-222 o-rings (12&20", 1&5 µm only) N = double open end (1, 3 & 5 µm – no gasket) XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 12 = 12, 19 = 19.5, 20 = 20, 30 = 30, 31 = 31, 40 = 40 XX . . . . . . . . . . . . . . . . . Micron Rating: 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 20 = 20 µm, 25 = 25 µm, 50 = 50 µm, 75 = 75 µm To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 37 CARTRIDGE FILTER - PARTICULATE Prepure DP™ Graded Density Polypropylene Depth Media Filter Cartridge • Composed of graded density melt blown polypropylene depth media for high efficiency prefiltration and post-filtration of DI resin applications • Prepure DP™ filtration cartridges feature high contaminant loading due to graded density depth filtration media construction • FDA Listed Materials - Manufactured from materials which are listed for food contact applications in Title 21 of the U.S. Code of Federal Regulations • All components meet the specifications for biological safety as per the USP for Class VI-121˚C plastics (gaskets/O-rings excluded). • Virgin polypropylene construction with fusion welding minimizes extractables SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.6" (6.6 cm) 9.75, 10, 20, 30, 40 Cartridge . . . . . . . . . . . . Media . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . Polypropylene caps, core and cage Non-woven melt blown polypropylene Silicone o-rings and gaskets Maximum Temperature . . . . . . . . . . . . . Maximum Differential Pressure @ 20°C Filtration Efficiency . . . . . . . . . . . . . . . . 180°F (82°C) @ 15 psid 75 psid (5.2 bard) Nominal 90% 0.5 – 5 micron. . . . . . . . 10 – 50 micron . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length) 5.0 gpm/10" length (18.9 lpm/10" length) Materials Operating Parameters Recommended Water Flow Rates Sanitizing Agents . . . . Chlorine or hydrogen peroxide ORDERING INFORMATION Catalog Number and Description FCDP . . . . . . . . . . . . . . All polypropylene depth filter cartridge X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 7 = 2-226 o-rings w/spear 1 = single open end w/internal o-ring F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 25 = 25 µm, 50 = 50 µm To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. Media Grade S5 1 3 5 10 25 50 Nominal .5 1 3 5 10 25 50 99.9% Abs 1 3 5 10 20 40 70 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 38 CARTRIDGE FILTER - PARTICULATE NT Series Graded Pore Polypropylene Depth Filter Cartridge • Designed to deliver precision prefiltration through the patented advanced melt blown structure that incorporates large diameter fibers for strength while maintaining small fibers for filtration • High purity, 100% polypropylene construction is free of surfactants, binders and adhesives • FDA Listed Materials - Manufactured from materials listed for food contact applications in Title 21 of the U.S. Code of Federal Regulations. Product (3 micron and higher) in compliance with EU Directive 2002/72/EC for plastic in food contact (in simulants A, B, C, and D). • Toxicity - All polypropylene components meet the specifications for biological safety as per the USP for Class VI-121˚C plastics (gaskets/O-rings excluded). SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.5" (6.5 cm) 9.75, 10, 20, 30, 40 Materials Cartridge . . . . . . . . . . . . Media . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . Operating Parameters Maximum Temperature 0.5-10 µm: . . . . . . . . . . . . . . . . . . . 15-120 µm: . . . . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 30°C Filtration Efficiency . . . . . . . . . . . . . . . . Recommended Water Flow Rates 0.5 – 3 micron. . . . . . . . 5 – 75 micron . . . . . . . . Sanitizing Agents . . . Polypropylene caps and core CoLD® fiber melt blown polypropylene Silicone o-rings and Santoprene® gaskets 15 psid (1.03 bard) @ 180˚F (82˚C) 25 psid (1.72 bard) @ 150˚F (66˚C) 60 psid (4.14 bard) @ 86˚F (30˚C) 25 psid (1.72 bard) @ 140˚F (60˚C) 50 psid (3.45 bard) @ ambient 60 psi (4.1 bar) Nominal 90% 2.0 gpm/10" length (7.6 lpm/10" length) 5.0 gpm/10" length (18.9 lpm/10" length) Chlorine, hydrogen peroxide Autoclaving: Single open end FCNT Series filter cartridges can be autoclaved for 30 minutes at 250˚F (121˚C) under no end load conditions. However, filter cartridges should be allowed to cool to normal system operating temperatures prior to use. Steam Sterilization: Not recommended. ORDERING INFORMATION Catalog Number and Description FCNT . . . . . . . . . . . . . . Polypropylene CoLD® depth filter cartridge X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 7 = 2-226 o-ring locking tabs w/spear 1 = single open end w/internal o-ring N = double open end (0.5 – 5 mm – no gasket) XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 15 = 15 µm, 20 = 20 µm, 30 = 30 µm, 40 = 40 µm, 50 = 50 µm, 75 = 75 µm Siemens Water Technologies 24-hr Customer Service: 800.466.7873 To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. BACK Section Table of Contents 39 CARTRIDGE FILTER - PARTICULATE Postpure PP™ Graded Density Pleated Polypropylene Depth Media Filter Cartridge • Composed of graded-density, pleated, polypropylene depth media for high efficiency postfiltration of DI resin applications • FDA Listed Materials - Manufactured from materials which are FDA listed for food contact applications in Title 21 of the U.S. Code of Federal Regulations. • Toxicity - All polypropylene components meet the specifications for biological safety as per the USP for Class VI-121˚C plastics (gaskets/O-rings excluded). • Cartridges are free of resins, binders and adhesives. SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.6" (6.6 cm) 10, 20, 30 Cartridge . . . . . . . . . . . . Media . . . . . . . . . . . . . . ................... Seals . . . . . . . . . . . . . . . Polypropylene caps, core and cage Pleated, non-woven melt blown polypropylene Silicone o-rings and gaskets Maximum Temperature . . . . . . . . . . . . . Maximum Differential Pressure @ 20°C Filtration Efficiency . . . . . . . . . . . . . . . . 150°F (65°C) @ 40 psid (2.8 bard) 75 psid (5.1 bard) nominal 90% 0.3 – 1 micron. . . . . . . . 3 – 30 micron . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length) 8.0 gpm/10" length (30.1 lpm/10" length) Materials Operating Parameters Recommended Water Flow Rates Sanitizing Agents Chlorine, hydrogen peroxide, in-line with hot water (82°C) for one hour, autoclaved for 20 minutes at 121°C under no load conditions. Sterilization Multiple autoclaving for 30 minutes at 250˚F (121˚C) under no end load conditions. Inline steam sterilization is not recommended. May be in-line sanitized with hot water at 180˚F (82˚C) for 1 hour. ORDERING INFORMATION Catalog Number and Description FCPP . . . . . . . . . . . . . . All polypropylene, pleated, nominal depth filter cartridge X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 w/spear 7 = 2-226 o-rings locking tabs w/spear 1 = single open end w/internal o-ring F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30 XX . . . . . . . . . . . . . . . . . Micron Rating: S3 = 0.3 µm, S6 = 0.6 µm, 01 =1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 30 = 30 µm To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 40 CARTRIDGE FILTER - PARTICULATE NA Series Absolute Rated Polypropylene Depth Filter Cartridge • Absolute filtration with sharp particle cutoffs deliver precise removal efficiencies • Patented melt blown structure provides outstanding retention efficiency, mechanical strength, and long on-stream life • High purity, 100% polypropylene construction is free of surfactants, binders and adhesives making these cartridges ideal for use in food and beverage applications • FDA Listed Materials - Manufactured from materials which are listed for food contact applications in Title 21 of the U.S. Code of Federal Regulations. Product (5 micron and higher) in compliance with EU Directive 2002/72/EC for plastic in food contact (in simulants A, B, C, and D). • Toxicity - All polypropylene components meet the specifications for biological safety as per the USP for Class VI-121˚C plastics (gaskets/O-rings excluded). SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . Materials Cartridge . . . . . . . . . . . . Media . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . Operating Parameters Maximum Temperature . . . . . . . . . . . . . 0.5-20 µm: . . . . . . . . . . . . . . . . . . . 30-120 µm: . . . . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 30°C Filtration Efficiency 2.5" (6.5 cm) 9.75, 10, 20, 30, 40 Polypropylene caps and core CoLD® fiber melt blown polypropylene Silicone o-rings and gaskets 15 psid (1.03 bard) @ 180˚F (82˚C) 25 psid (1.72 bard) @ 150˚F (66˚C) 60 psid (4.14 bard) @ 86˚F (30˚C) 25 psid (1.72 bard) @ 140˚F (60˚C) 50 psid (3.45 bard) @ ambient 60 psi (4.1 bar) Absolute (> 99.9% Retention Rating by ASTM F-795 Test) Recommended Water Flow Rates 0.5 – 5 micron. . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length) 10 – 70 micron . . . . . . . 5.0 gpm/10" length (18.9 lpm/10" length) Sanitizing Agents ................... Chlorine, hydrogen peroxide Autoclaving Single open end Nexis® Series filter cartridges can be autoclaved for 30 minutes at 250˚F (121˚C) under no end load conditions. However, filter cartridges should be allowed to cool to normal system operating temperatures prior to use. Steam Sterilization Not recommended ORDERING INFORMATION Catalog Number and Description FCNA . . . . . . . . . . . . . . Absolute rated CoLD depth filter cartridge X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 7 = 2-226 o-rings w/spear 1 = single open end w/ internal o-ring F = double open end w/flat gasket seal 5 = 2-222 o-rings w/spear XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 15 = 15 µm, 20 = 20 µm, 30 = 30 µm, 50 = 50 µm, 70 = 70 µm Siemens Water Technologies 24-hr Customer Service: 800.466.7873 To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. BACK Section Table of Contents 41 CARTRIDGE FILTER - PARTICULATE WN Series Pleated Polysulfone Membrane Filter Cartridge • Composed of pleated highly asymmetric polysulfone membrane over a nonwoven polypropylene support layer • For high flow rates and low pressure drops, absolute rated filters are designed for postfiltration in high purity water applications • High-purity construction materials are factory rinsed with DI water for quick onstream rinse up with a minimum of throughput • Meets criteria for USP Class VI Biological tests for plastics, ensuring that no surfactants or coatings interfere with the application • FDA listed materials - manufactured from materials which are FDA listed for food contact applications in Title 21 of the U.S. code of Federal Regulations SPECIFICATIONS Dimensions Diameter (OD) Length (in) ............... ............... 2.6" (6.6 cm) 9.75, 10, 20, 30, 40 Cartridge ............... Polypropylene caps, core and cage Materials Media Seals ............... ............... Operating Parameters Single layer asymmetric hydrophilic polysulfone Silicone o-rings and gaskets Maximum Temperature . . . . . . . . . . . . . . Maximum Differential Pressure @ 20°C . Filtration Efficiency . . . . . . . . . . . . . . . ............... 180°F (82°C) @ 50 psid (3.4 bard) 80 psi (5.5 bar) Absolute (> 99.9% Retention Rating by Latex Bead Challenge) 0.05 micron 0.1 micron 0.2 micron 0.45 micron ............... ............... ............... ............... 1.3 gpm/10" length (4.9 lpm/10" length) 1.7 gpm/10" length (6.4 lpm/10" length) 3.0 gpm/10" length (11.3 lpm/10" length) 5.5 gpm/10" length (20.8 lpm/10" length) ............... 5% Chlorine, 3% hydrogen peroxide Recommended Water Flow Rates Sanitizing Agents ORDERING INFORMATION Catalog Number and Description FCWN . . . . . . . . . . . . . . Filter cartridge single layer polysulfone X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear 1 = single open end w/ internal o-ring 7 = 2-226 o-rings w/locking tabs/spear end F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX(X) . . . . . . . . . . . . . . Micron Rating: S05 = 0.05 µm, S1 = 0.1 µm, S2 = 0.2 µm, S4 = 0.45 µm To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 42 CARTRIDGE FILTER - PARTICULATE WE Series Pleated Polysulfone Membrane Filter Cartridge • Composed of a double layer of integrity testable, highly asymmetric polysulfone membrane. These absolute rated filters offers superior bacteria and particle removal for high efficiency postfiltration for critical high purity water applications • Long on stream life, high flow rates and low pressure drops result from the membrane asymmetry • High-purity construction materials are factory flushed with DI water for quick on-stream rinse-up with a minimum of throughput • All polypropylene hardware and thermal welding minimizes extractables • All materials are FDA listed for contact with food and beverages SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . . . . . . . . . . . Length (in) . . . . . . . . . . . . . . . . . . . . . . . Materials Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . Media . . . . . . . . . . . . . . . . . . . . . . . . . . . polysulfone Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Rinse in @ 5-6 gpm per 10" to ensure removal of air and microbubbles between the membrane layers, especially with 0.02µ. Recommend flow per 10" is 2 gpm.) Operating Parameters Maximum Operating Temperature . . . . . Maximum Forward Differential Pressure ................................ ................................ Filtration Efficiency . . . . . . . . . . . . . . . . . Sanitizing Agents ................................ Integrity Test Pore Size . . . . . . . . . . . . . . . . . . . . . . . . 2.6" (6.6 cm) 9.75, 10, 20, 30, 40 Polypropylene caps, core and cage Double layer asymmetric hydrophilic Silicone o-rings and gaskets 86°F / 30°C (158˚F / 70˚C) 80 psid @68˚F / 5.5 bar @ 20˚C 20 psid @ 158˚F / 1.4 bar @ 70˚C 99.9% Absolute 5% Chlorine or 3% hydrogen peroxide Diffusional Flow (cc/min) @ Test Pressure per 10” length Diffusional Flow Valves (100% H20) (cc/min) @ Test pressure per 10” length 0.02 µm . . . . . . . . . . . . . . . . . . . . . . . . . < 30 cm3/min @ 50 psig / 3.4 bar 0.1 µm . . . . . . . . . . . . . . . . . . . . . . . . . . < 24 cm3/min @ 25 psig / 1.7 bar 0.2 µm . . . . . . . . . . . . . . . . . . . . . . . . . . < 20 cm3/min @ 20 psig / 1.4 bar 0.45 µm . . . . . . . . . . . . . . . . . . . . . . . . . < 15 cm3/min @ 15 psig / 1.0 bar ORDERING INFORMATION Catalog Number: FCWE . . . . . . X. . . . . . . . . . XX. . . . . . . . . XX(X) . . . . . . Filter cartridge double layer polysulfone Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear 1 = single open end w/ internal o-rings 7 = 2-226 o-rings w/locking tabs/spear end F = double open end w/flat gasket seal Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 Micron Rating: S02 = 0.02 µm, S1 = 0.1 µm, S2 = 0.2 µm, S4 = 0.45 µm Note: Not all part number combinations are available; consult Technical Support for assistance. To determine your catalog order number, replace the X with one of the numbered/lettered options beside it. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 43 CARTRIDGE FILTER - PARTICULATE DI Series Pleated Hydrophilic PVDF Media Pharmaceutical/Biotech Grade Filter Cartridge • Composed of a validatable, hydrophilic, PVDF membrane. Offering a high velocity DI water flush for quick rinse-up with no downstream contamination. • These absolute rated filters offer superior bacteria and particle removal for critical high purity postfiltration applications • Filters have single PVDF membrane with two layers of polypropylene support media to ensure absolute bacteria retention with typical LRV >8 • The all PVDF membrane can be sanitized with chlorine, hydrogen peroxide or steam • Virgin polypropylene construction with fusion welding minimizes extractables • Cartridges are 100% integrity tested to verify absolute sub-micron particle retention SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . . . . . . . . . . . . Length (in) . . . . . . . . . . . . . . . . . . . . . . . . Materials Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . 2.75" (7.0 cm) 10, 20, 30, 40 Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hydrophilic PVDF Silicone o-rings and gaskets Maximum Temperature . . . . . . . . . . . . . . Maximum Differential Pressure @ 25°C . Filtration Rating . . . . . . . . . . . . . . . . . . . . 176°F (80°C) @ 25 psid (1.7 bar) 50 psi (3.4 bar) 100% Absolute 0.1 micron . . . . . . . . . . . . . . . . . . . . . . . . 0.2 micron . . . . . . . . . . . . . . . . . . . . . . . . 0.5 gpm/10" length (1.9 lpm/10" length) 1.0 gpm/10" length (3.8 lpm/10" length) Operating Parameters Recommended Water Flow Rates Sanitizing Agents Chlorine, hydrogen peroxide Sterilization 30 SIP cycles of 30 min @ 121˚C; 30 autoclave cycles of 60 min @ 121˚C Integrity Test Pore Size . . . . . . . . . . . . . . . . . . . . . . . . . ............................... 0.1 µm . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.2 µm . . . . . . . . . . . . . . . . . . . . . . . . . . . Minimum Water Bubble Point @ 23˚C > 70 psig (≥ 4.8 bar) > 45 psig (≥ 3.1 bar) Diffusional Flow (cc/min) @ Test Pressure per 10" length in water < 20 @ 56 psig (3.8 bar) < 13.3 @ 40 psig (2.8 bar) ORDERING INFORMATION Catalog Number and Description FCDI . . . . . . . . . . . . . . . Filter cartridge Water DI X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear 7 = 2-226 o-rings w/locking tabs/spear end F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . Micron Rating: S1 = 0.1 µm, S2 = 0.2 µm To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 44 CARTRIDGE FILTER - PARTICULATE PV Series Pleated Hydrophilic PVDF Media Pharmaceutical Grade Filter Cartridge • Cartridge is a validated, pleated hydrophilic PVDF membrane over a non-woven polypropylene support layer • Code 0, Code 5, and Code 7 configurations are available in 10, 20 30, and 40-in lengths that are 100% tested in manufacturing to ensure absolute bacteria retention with typical titre reduction 7 2 of >10 /cm 7 2 • Quantitative retention of 10 CFU/cm Brevundimonas diminuta ATCC® 19146 per ASTM methodology • Component materials meet the criteria of the USP <88> Reactivity Test for Class VI Plastics. These products meet the requirements of the USP <88> Safety Test, utilizing a 0.9% sodium chloride extraction • Component materials meet the “non-fiber releasing” criteria as defined in 21 CFR 210.3 (b) (6) • Will meet the USP Oxidizable Substances Test requirements after a water flush of <1 L SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.75" (7.0 cm) 10, 20, 30, 40 Materials Cartridge . . . . . . . . . . . . Media . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . Operating Parameters Maximum Temperature . . . . . . . . . . . . . Maximum Differential Pressure @ 25°C Filtration Rating . . . . . . . . . . . . . . . . . . . Toxicity. . . . . . . . . . . . . . . . . . . . . . . . . . Validation . . . . . . . . . . . . . . . . . . . . . . . . Recommended Water Flow Rates 0.2 µm . . . . . . . . . . . . . Polypropylene caps, core and cage PVDF Silicone o-rings 176°F (80°C) @ 25 psid (1.7 bar) 80 psi (5.5 bar) 100% Absolute Non-toxic by USP Class VI biological test for plastics Quantitative Retention of 107 CFU/cm2 per ASTM methodology 1.0 gpm/10" length (3.8 lpm/10" length) Sanitizing Agents ................... Chlorine, hydrogen peroxide Sterilization ................... 30 SIP cycles of 30 min @ 135˚C; 30 autoclave cycles of 60 min @ 126˚C Integrity Test Pore Size Minimum Water Diffusional Flow (cc/min) Bubble Point @ 23˚C @ Test Pressure per 10" length > 50 psig (> 3.45 bar) < 13.3 @ 40 psig (3.1 bar) 0.2 µm . . . . . . . . . . . . . ORDERING INFORMATION Catalog Number and Description FCPV . . . . . . . . . . . . . . Filter cartridge pharmaceutical/validated X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end 7 = 2-226 o-rings w/locking tabs/spear end XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30 S2 . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 µm To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 45 CARTRIDGE FILTER - PARTICULATE VH Series Pleated PES Media Pharmaceutical Grade Filter Cartridge • Cartridge is a validated, pleated polyethersulphone membrane over a non-woven polyester support layer • Code 0, Code 5, Code 7 and Code 10 configurations are available in 10, 20 30, and 40-in lengths that are 100% tested in manufacturing to ensure absolute bacteria retention • Materials conform to the relevant requirements of 21CFR Part 177 and current USP Plastics Class VI-121˚C and ISO10993 equivalents • FCVH Series Sterilizing Grade 0.2 micron filters are validated by bacterial challenge 7 2 testing to methods specified in ASTM F838-83 (10 organisms/cm minimum) 11 with typical in-house challenge levels being 10 per 10 inch module for Brevundimonas diminuta • Contain no surfactants or coatings to interfere with your application, and the thermo-plastic construction process minimizes extractables. SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . Materials Cartridge . . . . . . . . . . . . 2.75" (7.0 cm) 10, 20, 30, 40 Support . . . . . . . . . . . . . Media . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . Operating Parameters Maximum Temperature . . . . . . . . . . . . . Maximum Differential Pressure @ 25°C Filtration Rating . . . . . . . . . . . . . . . . . . . Toxicity. . . . . . . . . . . . . . . . . . . . . . . . . . Validation . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene, core and cage, nylon endcaps with 316LSS insert Polyester Polyethersulphone Silicone o-rings 176°F (80°C) @ 29 psid (2.0 bard) 72 psi (5.0 bar) 100% Absolute Non-toxic by USP Class VI biological test for plastics Microbially retentive and validated to ASTM F838-83 methodology Recommended Water Flow Rates 0.1 µm . . . . . . . . . . . . . 1.8 gpm/10" length (2.3 lpm/10" length) 0.2 µm . . . . . . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length) 0.45 µm . . . . . . . . . . . . 3.0 gpm/10" length (11.4 lpm/10" length) Sanitizing Agents Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121°C under no load conditions. Sterilization FCVH cartridges can be repeatedly in-situ steam sterilized or autoclaved up to 130˚C (266˚F). They can be sanitized with hot water at up to 90˚C (194˚F) and are compatible with a wide range of chemicals. Integrity Test Pore Size . . . . . . . . . . . . . . . . Minimum Water Diffusional Flow (cc/min) Bubble Point @ Test Pressure per 10" length 0.1 µm . . . . . . . . . . . . . . . . . . ≥ 34.2 psig* ≤ 27 @ 70 psig (4.9 bar) 0.2 µm . . . . . . . . . . . . . . . . . . ≥ 49 psig ≤ 16 @ 40 psig (2.7 bar) 0.45 µm . . . . . . . . . . . . . . . . . ≥ 36 psig ≤ 16 @ 25 psig (1.7 bar) * 60/40 IPA water test solution ORDERING INFORMATION Catalog Number and Description FCVH . . . . . . . . . . . . . . Filter cartridge pharmaceutical/validated X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 1 = single open end w/internal o-ring 5 = 2-222 o-rings w/spear end 7 = 2-226 o-rings w/locking tabs/spear end XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . Micron Rating: S1 = 0.1 µm, S2 = 0.2 µm, S4 = 0.45 µm To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 46 CARTRIDGE FILTER - PARTICULATE UF Series Hollow Fiber Polysulfone Media Filter Cartridge • Composed of validatable hollow fiber polysulfone media with polypropylene hardware • These absolute rated filters offer excellent bacteria, particle and pyrogen removal for critical pharmaceutical and life science applications, at economical costs • Code 0, Code 5, and Code 7 configurations are available in 10, 20, 30 and 40-in lengths • Meet current USP Class VI biological test for plastics, with a validation certificate available • Contain no surfactants or coatings to interfere with your application, and thermo-plastic construction process minimizes extractables • Hollow fiber construction ensures strength, while exhibiting low pressure drop and exceptionally high flow rates • Multi-tube applications require special housings - contact Technical Support SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.9" (7.4 cm) 10, 20, 30, 40 Cartridge . . . . . . . . . . . . Media . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . Polypropylene caps and cage, polyurethane end sealant Polysulfone fibers Silicone o-rings Maximum Temperature . . . . . . . . . . . . . Maximum Differential Pressure . . . . . . . Filtration Rating . . . . . . . . . . . . . . . . . . . Toxicity. . . . . . . . . . . . . . . . . . . . . . . . . . Validation . . . . . . . . . . . . . . . . . . . . . . . . 185°F (85°C) @ 10 psid (.7 bar) 30 psi (2 bar) @ 25°C 100% Absolute Non-toxic by USP Class VI biological test for plastics Diffusive flow test methods 0.05 micron . . . . . . . . . . 0.1 and 0.2 micron . . . . 2.0 gpm/10" length (7.6 lpm/10" length) 3.0 gpm/10" length (11.4 lpm/10" length) Materials Operating Parameters Recommended Water Flow Rates Sanitizing Agents ................... ................... Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121°C under no load conditions ORDERING INFORMATION Catalog Number and Description FCUF . . . . . . . . . . . . . . Filter cartridge ultra filter X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end 1 = single open end w/ internal o-ring 7 = 2-226 o-rings w/locking tabs/spear end XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX(X) . . . . . . . . . . . . . . Micron Rating: S05 = 0.05 µm, S1 = 0.1 µm, S2 = 0.2 µm To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 47 CARTRIDGE FILTER - HOUSING 316 Stainless Steel, Single-Tube Filter Housing For Code F This single-tube cartridge filter housing is made of cast 316 stainless steel and includes 316 stainless steel shell. Housings are available to accommodate 10, 20 or 30-in Code F filter cartridges. The inlet and outlet are 3/4" NPT, and the bowl of each housing is fitted with a 1/4" NPT drain plug. This cartridge filter housing is ideal for a wide variety of low flow applications requiring a high quality prefilter housing or for applications where an industrial pre-filter is used. • Single tube housings accommodate 10", 20" and 30" Code F filter cartridges • Housing uses 316SS for construction of the head, bowl and port plug • Inlet and outlet connections are made to the housing head, allowing cartridges to be replaced without disconnecting the inlet/outlet piping • Housing can be autoclaved or hot-water sanitized with the cartridges in place for your convenience SPECIFICATIONS Dimensions 10-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials Length (A) 13.5" (34.3 cm) 23.5" (59.7 cm) 33.5" (85.1 cm) Width (B) 4.75 (12.1 cm) 4.75 (12.1 cm) 4.75 (12.1 cm) Bowl and Head . . . . . . . . . . . . . . . . . . . Port Plugs . . . . . . . . . . . . . . . . . . . . . . . O-ring. . . . . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel 316 stainless steel Ethylene Propylene Max Operating Pressure . . . . . . . . . . . Max Housing Flow Rate . . . . . . . . . . . . 175 psi (12.1 bar) @ 200°F (93°C) 12 gpm (45.4 lpm) Operating Parameters Note: Housing rating only, safe operating pressure will depend on filter cartridge and gaskets used. Connections Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . . . Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4" NPT 1/4" NPT Mounting Should be mounted by rigid pipe connections or with optional mounting bracket. Allow enough clearance below bottom of housing to allow cartridge to be changed. Flow Direction “Inlet” and “Outlet” are cast on the housing head for user convenience. ORDERING INFORMATION Catalog Number and Description ZHDFD1001 10" housing ZHDFD2001 20" housing ZHDXDB001 Mounting Bracket ZHDFD3001 B10015866 30" housing Shell O-ring EPDM Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 48 CARTRIDGE FILTER - HOUSING 316L Stainless Steel, Single-Tube Filter Housing For Code O This single-tube cartridge filter housing is made of 316L stainless steel and includes 316 stainless steel port plugs. Housings are available to accommodate 10, 20 or 30-in Code 0 filter cartridges. The inlet and outlet are 3/4" NPT, and the bowl of each housing is fitted with a 1/4" NPT drain plug. This cartridge filter housing is ideal for a wide variety of low flow applications requiring a high quality prefilter housing or for applications where an industrial pre-filter is used. • Inlet and outlet connections are made to the housing head, allowing cartridges to be replaced without disconnecting the inlet/outlet piping • Bowl incorporates a satin finish to help prevent bacterial build-up • Housing can be autoclaved or hot-water sanitized with the cartridges in place for your convenience • Two vent ports are included in the head for venting, or for the installation of pressure gauges SYSTEM SPECIFICATIONS Dimensions 10-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials Head . . . . . . . . . . . . . . . . . . . . . . . . . . . Bowl and Plugs . . . . . . . . . . . . . . . . . . . O-ring. . . . . . . . . . . . . . . . . . . . . . . . . . . Length (A) 14.8" (37.5 cm) 24.8" (62.9 cm) 34.8" (88.4 cm) Width (B) 4.2 (10.5 cm) 4.2 (10.5 cm) 4.2 (10.5 cm) 316L stainless steel 316 stainless steel EPDM Surface Finish Head . . . . . . . . . . . . . . . . . . . . . . . . . . . Cartridge Sealing Surface . . . . . . . . . . . Bowl. . . . . . . . . . . . . . . . . . . . . . . . . . . . Sand Blasted Finish 32 RMS Finish Satin Finish Operating Parameters Max Inlet Pressure . . . . . . . . . . . . . . . . 175 psi (12.1 bar) @ 150°F(66°C) Note: Housing rating only, safe operating pressure will depend on filter cartridge and gaskets used. Connections Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . . . Drain and Vent. . . . . . . . . . . . . . . . . . . . 3/4" NPT 1/4" NPT Mounting Should be mounted by rigid pipe connections or optional mounting bracket. Allow enough clearance below bottom of housing to allow cartridge to be changed. Flow Direction “Inlet” and “Outlet” are electroetched on the housing head for user convenience. ORDERING INFORMATION Catalog Number and Description ZHD0D1001 10" housing ZHD0D2001 20" housing ZHDXDB001 Mounting Bracket ZHD0D3001 B10015866 30" housing Shell O-ring EPDM Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 49 CARTRIDGE FILTER - HOUSING 316L Electropolished Stainless Steel, Multi-Tube Filter Housing For Code 5 or Code O This multi-tube cartridge filter housing is made of electropolished 316L stainless steel. Housings are available to accommodate 7 cartridges in 10, 20, 30 or 40" length, Code 5 or Code 0 configurations with two 222 o-rings. The bottom of each housing is fitted with a 3/4" NPTF drain plug. And each housing is equipped with a NPTF vent at the top of the housing. A V-band clamp closure allows cartridges to be changed quickly and easily. • Housing uses electropolished 316L stainless steel construction that is easy to clean and provides maximum corrosion resistance • Predrilled support stand allows the housing to be secured to floor or some mounting surface • A 1/4" NPTF air vent plug on the cover allows venting before start-up FILTER HOUSING SPECIFICATIONS Dimensions Inlet/Outlet Housing Dimensions (inches (cm) 7-round 10" 7-round 20" 7-round 30" 7-round 40" Materials 2" NPTM (5.1) 2" NPTM (5.1) 2" NPTM (5.1) 2" NPTM (5.1) A 25 (64) 33.5 (85) 44 (112) 54.5 (138) Head and Shell . . . . . . . . . . . . . . . . . . . Vent and Drain Plug . . . . . . . . . . . . . . . Seat Cups . . . . . . . . . . . . . . . . . . . . . . . O-Ring . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Parameters B 11.5 (29) 11.5 (29) 11.5 (29) 11.5 (29) C 5.5 (14) 5.5 (14) 5.5 (14) 5.5 (14) D 12 (30) 12 (30) 12 (30) 12 (30) Flange Option Max. Flow E 12.8" (32) 12.8" (32) 12.8" (32) 12.8" (32) Rate*/gpm (lpm) 35 (132) 70 (264) 105 (398) 140 (530) 316L Stainless Steel electropolished 316 Stainless Steel 316L Stainless Steel Ethylene Propylene Maximum Operating Pressure . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C) Maximum Water Flow Rate* . . . . . . . . . 140 gpm (528 Lpm) *Housing rating only, cartridge length and type will effect maximum flow rates ORDERING INFORMATION Catalog Number Description Inlet/Outlet ZHH000720 2" NPTM ZHH000710 7-round 10" ZHH000730 7-round 30" ZHH000740 ZHH000710F 2" NPTM 7-round 20" 2" NPTM 7-round 40" 2" NPTM 7-round 10" 2" flange ZHH000720F 7-round 20" 2" flange ZHH000740F 7-round 40" 2" flange ZHH000730F B10016248 7-round 30" 2" flange Spare Housing O-Ring EPDM Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 50 CARTRIDGE FILTER - HOUSING 316L Stainless Steel, Multi-Tube High Purity Housing For Code 0 and Code 5, option for Code 7 This multi-tube cartridge filter housing is made of 316L stainless steel, and suited to high purity and sanitary applications. These housings include options to accommodate Code 0 and 5 or Code 7 filter cartridges. • High quality, crevice free construction • External mirror polished, internally polished to 32 Ra–EP option ZHHP 3/5/8 Round • Steam sterilizable • Sanitary Tri-Clamp, vent and drain connections • Band clamp or Rathmann style screw clamp (used on 12, 18, 24 and 30 round vessels) body closure as standard for additional security • Inlet/outlet available with Tri-Clamp (below) or ANSI flange connections • Available in Code 0 and 5 (below) or optional Code 7 end cap configuration PRODUCT SPECIFICATIONS Head and Shell . . . . . . . . . . . . . . . . . . . 316L Stainless Steel Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . Silicone Surface Finish . . . . . . . . . . . . . . . . . . . . Internal: mechanical polish 32Ra External: mechanical polish, EP option Cartridge Configuration . . . . . . . . . . . . . Code 0 and 5, Code 7 option Maximum Operating Pressure . . . . . . . 3–8 Round:145 psig @ 104˚F 12 Round: 130.5 psig @ 104˚F Maximum Operating Temperature . . . . . 3–8 Round: 302˚F @ 108.75 psig 12 Round: 302˚F @ 101.50 psig ORDERING INFORMATION Part Number Cartridge ZHHP0N0320T ZHHP0N0330T ZHHP0N0520T ZHHP0N0530T ZHHP0N0820T ZHHP0N0830T ZHHP0N1220T ZHHP0N1230T No. Length 3 3 5 5 8 8 12 12 20 30 20 30 20 30 20 30 Vessel Size 3 round 5 round 8 round 12 round A (in) B (in) ZHHP 12 Round C (in) Dia. X-port Pipe Dia. 6.6 6.6 8.6 8.6 10.7 10.7 13.8 13.8 14.2 14.2 16.5 16.5 17.6 17.6 26.9 26.9 1–1/2" 1–1/2" 2" 2" 2" 2" 3" 3" Tri-Clamp Size (in) 1-1/2" 2" 2" 3" D (in) Overall Height 41.3 51.2 41.3 51.2 41.3 51.2 47.2 57.1 E (in) Required Clearance 21.3 31.1 21.3 31.1 21.3 31.1 21.3 31.1 Total Volume (L) 12.6 17.8 20 29.1 35.5 49.7 65 88 Total Net Weight (kg) 19.4 21.4 20 22 30 33 14.5 19 Flange Size (in) 1-1/4" 1-1/2" 1-1/2" 3" Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 51 CARTRIDGE FILTER - HOUSING 316 Stainless Steel, Multi-Tube Filter Housing For Code F This multi-tube cartridge filter housing is made of 316 stainless steel, and is suited for general-purpose industrial and commercial filtration. These housings can accommodate Code F (DOE) or Code 0 cartridges, and are available with 6, 12, and 21 tubes in 10, 20, 30, 40-inch lengths. • Incorporates a flow baffle, which deflects incoming flow to prevent cartridge erosion • An air vent on the cover allows venting before start-up • A swing bolt closure allows quick disassembly for cleaning and cartridge replacement 6-ROUND DIMENSIONS 12- AND 21-ROUND DIMENSIONS Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 52 CARTRIDGE FILTER - HOUSING 316 Stainless Steel, Multi-Tube Filter Housing FILTER HOUSING SPECIFICATIONS Dimensions (inches (cm) Inlet/Outlet 6-round 10” 6-round 20” 6-round 30” 6-round 40” 12-round 30” 12-round 40” 21-round 30” 21-round 40” 2 NPTM (5.1) 2 NPTM (5.1) 2 NPTM (5.1) 2 NPTM (5.1) 3 flange (7.6) 3 flange (7.6) 4 flange (10.16) 4 flange (10.16) Materials Housing Dimensions A B 24 (61) 34 (86) 45 (114) 56 (142) 56 (142) 66 (168) 57 (145) 67 (170) 11.2 (28) 11.2 (28) 11.2 (28) 11.2 (28) 31 (79) 31 (79) 31 (79) 31 (79) C 5.2 (13) 5.2 (13) 5.2 (13) 5.2 (13) 12 (30) 12 (30) 12 (30) 12 (30) D 10.2 (26) 10.2 (26) 10.2 (26) 10.2 (26) 12 (30) 12 (30) 16 (41) 16 (41) Flange Option E 15 (38) 15 (38) 15 (38) 15 (38) 16.4 (42) 16.4 (42) 20.8 (53) 20.8 (53) Max. Flow Rate*/gpm (lpm) 30 (114) 60 (227) 90 (340) 120 (454) 180 (680) 240 (908) 315 (1190) 420 (1560) Head, Shell, Plugs. . . 316L Stainless Steel Internals. . . . . . . . . . . 316 Stainless Steel Cover O-Ring. . . . . . . EDPM Maximum Operating Pressure 6-Round. . . . . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C) 12-Round. . . . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C) 21-Round. . . . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C) ORDERING INFORMATION Catalog Number Description Inlet/Outlet ZHGOF0620 6-round 20" 2" NPT ZHGOF0610 ZHGOF0630 ZHGOF0640 ZHGOF0610F ZHGOF0620F 6-round 10" 2" NPT 6-round 30" 2" NPT 6-round 40" 2" NPT 6-round 20" 2" flange 6-round 10" 2" flange ZHGOF0630F 6-round 30" 2" flange ZHFFI1230 12-round 30" 3" flange ZHGOF0640F ZHFFI1240 ZHFFI2130 ZHFFI2140 B10020279 B10015430 6-round 40" 2" flange 12-round 40" 3" flange 21-round 40" 4" flange 21-round 30" 4" flange Replacement O-ring EPDM 6-round Replacement O-ring EPDM 12-round *Housing rating only, cartridge length and type will effect maximum flow rates Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 53 CARTRIDGE FILTER - HOUSING 304 Stainless Steel, Multi-Tube Filter Housing with V-Clamp Closure For Code F This multi-tube cartridge filter housing is made of durable 304 stainless steel, and is suited for general-purpose industrial and commercial filtration. These housings can accommodate Code F (DOE, internals provided), and can be configured for Code 0 and Code 5 cartridges. • Incorporates a flow baffle, which deflects incoming flow to prevent cartridge erosion • A 1/4" NPT air vent on the cover allows venting before start-up • A 3/4" NPT drain plug allows for liquid removal • Cartridges are independently sealed inside the housing and a single V-band clamp housing closure allows easy cartridge replacement • Cartridge post can be lifted out, allowing easy removal of cartridges at the bottom of the stack FILTER HOUSING SPECIFICATIONS Cartridge Inlet/Outlet Housing Dimensions/Inches (cm) Housing Inches (cm) A B C D 5-round 10" 5-round 20" 5-round 30" 5-round 40" Materials 1-1/2 NPTM (3.8) 1-1/2 NPTM (3.8) 2 NPTM (5.1) 2 NPTM (5.1) 25 (64) 32.5 (85) 44 (112) 54.5 (138) Head, Shell, Plugs. . . . . . . . . . . . . . . . . Internals. . . . . . . . . . . . . . . . . . . . . . . . . Cover O-Ring. . . . . . . . . . . . . . . . . . . . . Hold Down Plate Nut . . . . . . . . . . . . . . . Operating Parameters 11.5 (29) 11.5 (29) 11.5 (29) 11.5 (29) 5.5 (14) 5.5 (14) 5.5 (14) 5.5 (14) 12 (30) 12 (30) 12 (30) 12 (30) Flange Opt. E 12.75 (32) 12.75 (32) 12.75 (32) 12.75 (32) Max. Flow Rate*/gpm (lpm) 25 (94.6) 50 (189) 75 (284) 100 (378) 304 Stainless Steel 316 Stainless Steel Ethylene Propylene Polypropylene Maximum Operating Pressure. . . . . . . . 150 psi (10.7 bar) @ 200°F (93°C) Maximum Housing Flow Rates* . . . . . . 100 gpm (378 lpm) *Housing rating only, cartridge length and type will effect maximum flow rates ORDERING INFORMATION Catalog Number Description Inlet/Outlet ZHFFI0520 1-1/2" NPT ZHFFI0510 ZHFFI0530 5-round 10" 1-1/2" NPT 5-round 20" 5-round 30" 2" NPT ZHFFI0540 5-round 40" 2" NPT ZHFFI0520F 5-round 20" 1-1/2" Flange ZHFFI0510F 5-round 10" 1-1/2" Flange ZHFFI0530F 5-round 30" B10016248 Spare Housing O-Ring EPDM ZHFFI0540F 2" Flange 5-round 40" 2" Flange **Flange inlet and outlet are also available; add F Suffix to part number Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 54 CARTRIDGE FILTER - HOUSING 304 Stainless Steel, Multi-Tube Filter Housing with Swing Bolt Closure For Code F This multi-tube cartridge filter housing is made of 18 gauge 304 stainless steel. Housings are available to accommodate 6, 10, 20, 30 or 40-in, Code F filter cartridges. The inlet and outlet are 2" NPT. There is a 1/2" NPT drain plug, and a 1/4" NPT vent at the top of the housing. A swing bolt closure allows quick disassembly for cleaning and service. This cartridge filter housing is ideal for a wide variety of high flow applications that require an economical, high quality housing. • Uses 304 stainless steel construction for maximum corrosion resistance to deliver years of dependable service • A swing bolt closure allows quick disassembly for cleaning and service • An air vent plug on the cover allows venting before start-up • This housing accommodates liquid flow rates up to 180 gpm (681 lpm) with operating pressures to 150 psig (10.3 bar) FILTER HOUSING SPECIFICATIONS Cartridge Housing Dimensions/Inches (cm) Housing A B C D 6-round 10" 6-round 20" 6-round 30" 6-round 40" Materials 24 (61) 34 (86) 45 (114) 56 (142) 11.2 (28) 11.2 (28) 11.2 (28) 11.2 (28) Head and Shell . . . . . . . . . . . . . . . . . . . Vent and Drain Plug . . . . . . . . . . . . . . . Seat Cups . . . . . . . . . . . . . . . . . . . . . . . O-Ring . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Parameters 5.2 (13) 5.2 (13) 5.2 (13) 5.2 (13) 10.2 (26) 10.2 (26) 10.2 (26) 10.2 (26) Flange Opt. E 15 (38) 15 (38) 15 (38) 15 (38) Max. Flow Rate*/gpm (lpm) 30 (114) 60 (227) 90 (340) 120 (454) 304 Stainless Steel 304 Stainless Steel 316L Stainless Steel Ethylene Propylene Maximum Operating Pressure . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C) Max Water Flow Rate*. . . . . . . . . . . . . . 120 gpm (454 Lpm) *Housing rating only, cartridge length and type will effect maximum flow rates ORDERING INFORMATION Catalog Number Description Inlet/Outlet ZHGAF0610 6-round 10" ZHGAF0630 6-round 30" 2" NPT ZHGAF0610F 6-round 10" 2" flange ZHGAF0620 ZHGAF0640 ZHGAF0620F ZHGAF0630F ZHGAF0640F B10020279 6-round 20" 6-round 40" 6-round 20" 6-round 30" 6-round 40" 2" NPT 2" NPT 2" NPT 2" flange 2" flange 2" flange Spare Housing O-ring Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 55 CARTRIDGE FILTER - HOUSING Polypropylene Plastic Filter Housings These filter housings are molded from polypropylene, and are available in 10 and 20 inch lengths. Housings are supplied with 3/4" inlet and outlets in standard flat gasket design for Code F filter cartridges. Heads are available with double cap plug design and Viton® o-rings. • Durable housings are made from all polypropylene materials • Housings contain no fillers, colorants, plasticizers, or lubricants • Housings are autoclavable, ETO sterilizable, and hydrogen peroxide compatible • Supplied with 3/4" NPT inlet and outlets in standard flat gasket design for Code F filter cartridges FILTER HOUSING SPECIFICATIONS Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5" ID, 5 1/8” OD maximum polypropylene cap and housing with standard Viton® E-60 o-rings 125 psi (8.6 bar) 100°F (38°C) Maximum Operating Pressure . . . . . . . . . . . . . . . . . . . . Maximum Operating Temperature . . . . . . . . . . . . . . . . . Sterilization/Sanitization Hydrogen Peroxide . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5% compatibility; static soak up to 24 hr at ambient temperature Weight 10" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 lb (1.4 kg) 4.25 lb (1.9 kg) Housing Compatibility/Cartridge Type ZHCFA1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHCFA2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ORDERING INFORMATION Catalog Number: ZHC Code F, 9 3/4” Code F, 20” F A XX Polypropylene System Name. . . . . . . . . . . . . filter housing Cartridge Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F = Code F Cartridge Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A = No plugs 10 = 10 Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 = 20 Number of Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To figure your order number, replace the X with one of the numbered options below it. ACCESSORIES Description Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-ring replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . XX 01 = 1 tube Catalog Number ZHA150060 FC150295 ZHA151021 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 56 CARTRIDGE FILTER - HOUSING White Polypropylene Plastic Filter Housing for Dialysis Filtration Applications These filter housings are molded from a white colored, high-density polypropylene, and are available in 12 and 20 inch lengths to accommodate 10 and 20 inch Code 0 filter cartridges. Housings are molded in dies that are minutely polished for an ultra-smooth finish to all contact surfaces, thus minimizing the opportunity for bacteria adhesion. Housings are supplied with 3/4" inlet and outlets. Heads are available with double cap plug design and Viton® o-rings. • Durable housings are made from all polypropylene materials with FDA approved white colorant • O-rings are molded of FDA approved Viton® • Available in 222 o-ring design for Code 0 filter cartridges • Housings are hydrogen peroxide compatible • Supplied with 3/4" NPT inlet and outlets FILTER HOUSING SPECIFICATIONS Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5" ID, 5 1/8” OD maximum White colored polypropylene cap and housing with standard Viton® E-60 o-rings 100 psi (6.9 bar) 100˚ F (35˚C) Maximum Operating Pressure . . . . . . . . . . . . . . . . . . . . Maximum Operating Temperature . . . . . . . . . . . . . . . . . Sterilization/Sanitization Hydrogen Peroxide . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5% compatibility; static soak up to 24 hr at ambient temperature Weight 12" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 lb (1.6 kg) 4.25 lb (1.9 kg) Housing Compatibility/Cartridge Type ZHW0D1201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHW0D2001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ORDERING INFORMATION Catalog Number: ZHW Code 0, 10" Code 0, 20" X X XX White polypropylene System Name. . . . . . . . . . . . . filter housing Cartridge Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 = Code 0 Housing Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D = Double cap plug 12 = 12 Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 = 20 Number of Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To figure your order number, replace the X with one of the numbered/lettered options below it. ACCESSORIES Description Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-ring Viton® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . XX 01 = 1 tube Catalog Number ZHA150060 ZHA151117 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 57 CARTRIDGE FILTER - HOUSING Natural Polypropylene Plastic Filter Housing These filter housings are molded from natural, high-density polypropylene, and is available in 10, 12 and 20 inch lengths. Housings are molded in dies that are minutely polished for an ultra-smooth finish to all contact surfaces, thus minimizing the opportunity for bacteria adhesion. Housings are supplied with 3/4" inlet and outlets in standard flat gasket design for Code F filter cartridges, and 222 o-ring design for Code 0 filter cartridges. Heads are available with double cap plug design and Viton® o-rings. • Durable housings are made from all polypropylene materials (except for o-rings) • Housings contain no fillers, colorants, plasticizers, or lubricants • Available in flat gasket design for Code F filter cartridges, and 222 o-ring design for Code 0 filter cartridges • Housings are autoclavable and hydrogen peroxide compatible • Supplied with 3/4" NPT inlet and outlets FILTER HOUSING SPECIFICATIONS Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5" ID, 5 1/8” OD maximum Natural polypropylene cap and housing with standard Viton® E-60 o-rings 100 psi 38° C (100°F) Maximum Operating Pressure . . . . . . . . . . . . . . . . . . . . Maximum Operating Temperature . . . . . . . . . . . . . . . . . Sterilization/Sanitization Autoclavable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hydrogen Peroxide . . . . . . . . . . . . . . . . . . . . . . . . . . 25 min 121-127°C (252-260°F) 7.5% compatibility; static soak up to 24 hr at ambient temperature Weight 10" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 lb (1.4 kg) 3.5 lb (1.6 kg) 4.25 lb (1.9 kg) Housing Compatibility/Cartridge Type ZHA0D1201* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHA0D2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHAFD1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHAFD2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code 0, 10" Code 0, 20" Code F, 9 3/4" Code F, 20" *Code 0, 10" cartridge must be used with 12" housing *Code 0 cartridge requires 12" housing ORDERING INFORMATION Catalog Number: ZHA X X XX Natural polypropylene System Name. . . . . . . . . . . . . filter housing F = Code F Cartridge Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 = Code 0 10 = 10 Housing Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D = Double cap plug 12 = 12 Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 = 20 Number of Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To figure your order number, replace the X with one of the numbered/lettered options below it. XX 01 = 1 tube *Code 0 cartridge requires 12" housing ACCESSORIES Description Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-ring Viton® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BACK Catalog Number ZHA150060 ZHA151117 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 58 CARTRIDGE FILTER - SPECIALTY CARTRIDGE CLERIFY™ Oil Adsorption Filter Cartridge • Composed of sheets of modified cellulose material rolled on a central polypropylene support core • Removes 95% of total hydrocarbons from water in a single pass. The media can adsorb up to 300% of its own weight in oils • Available in 2.75" and 4.6" diameters and lengths to 40" CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . . . . . . . . . Length ................... 2.75" (7.0 cm ) or 4.5" (11.7 cm ) 9.75", 10", 20", 30", 40” Materials Media ..................... Core . . . . . . . . . . . . . . . . . . . . . . . . . . Gaskets . . . . . . . . . . . . . . . . . . . . . Modified Cellulose Polypropylene Buna N Operating Parameters Max. Temperature ............ Max. Differential Pressure . . . . . . . . 120° F (50° C) 36 psi (2.5 bar) @ 25°C Recommended Water Flow Rates 2.75" Diameter . . . . . . . . . . . . . . . . . 4.60" Diameter . . . . . . . . . . . . . . . . ORDERING INFORMATION 5.0 gpm/10" Length (18.9 lpm/10" Length) 5.0 gpm/10" Length (18.9 lpm/10" Length) Catalog Number: HAC Hydrocarbon Adsorption Cartridge . HAC X X XX X X 09 = 9.75 A = 2.75" 0 = 2-222 O-Rings 10 = 10 Cartridge Diameter . . . . . . . . . . . . . . . . . . . . B = 4.5" F = Double open end 20 = 20 Cartridge Code ................................ w/flat gasket seals 30 = 30 Length (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 = 40 Core Material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P = Polypropylene Gasket Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B = Buna N Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 59 CARTRIDGE FILTER - VENT FILTER Hydrophobic PTFE Media Vent Capsule Filter • Composed of a pleated hydrophobic PTFE filter membrane rated at 0.01 µm absolute for small volume storage tank venting applications • Convenient threaded inlet, with 1/2" NPTM inlet fitting screws into 1/2" NPTF bulkhead fitting, eliminates the need for a filter housing • Hydrophobic expanded PTFE membranes are fully validated by bacterial challenge test methods • Filters feature thermally-bonded polypropylene cage without using adhesives to ensure low extractables • 100% integrity tested in manufacturing and can be repeatedly autoclaved with steam up to 140°C CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Length (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inner Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.48" (5.6 cm) 5.9 (15 cm) 1/2" NPTM Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene PTFE Membrane Maximum Temperature . . . . . . . . . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 80°C (176˚F) . . . . Air Filtration Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . 60˚C (140˚F) 65 psig (4.5 bar) 0.01 µm 100% Absolute Materials Operating Parameters ORDERING INFORMATION Catalog Number and Description FCVPTO6S1 Capsule Hydrophobic PTFE Filter NOTE: These filter cartridges should not be used as a combination air vent/water overflow device. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 60 CARTRIDGE FILTER - VENT FILTER EA Series Hydrophobic Polypropylene Media Vent Filter Cartridge • Composed of a pleated hydrophobic highly asymmetric polysulfone membrane rated at 0.02 µm absolute for sterile air filtration, storage tank venting applications • Filter components meet current USP Class VI biological test for plastics • Contain no surfactants or coatings to interfere with your application, and the thermo-plastic construction process minimizes extractables • Asymmetric single layer membrane ensures strength, while exhibiting low pressure drop and exceptionally high flow rates • Sterilized by autoclaving CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.6" (6.6 cm) 10, 20, 30 Cartridge . . . . . . . . . . . . Media . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . Polypropylene caps, core and cage Hydrophobic asymmetric polysulfone Silicone o-rings and gaskets Maximum Temperature . . . . . . . . . . . . . Maximum Differential Pressure @ 23°C Air Filtration Rating . . . . . . . . . . . . . . . . Toxicity. . . . . . . . . . . . . . . . . . . . . . . . . . Sanitizing Agents .............................. Ambient Air 60 psi (4.1 bar) 0.02 µm 100% Absolute Non-toxic by USP Class VI biological test for plastics Materials Operating Parameters Chlorine, hydrogen peroxide or autoclaving ORDERING INFORMATION Catalog Number and Description FCEA . . . . . . . . . . . . . . Filter cartridge vent polysulfone X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end 1 = single open end w/internal o-ring 7 = 2-226 o-rings w/locking tabs/spear end F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30 S2 . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.02 µm (air) To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. NOTE: These filter cartridges should not be used as a combination air vent/water overflow device. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 61 CARTRIDGE FILTER - VENT FILTER VA Series Hydrophobic PTFE Validated Membrane Vent Filter Cartridge • Hydrophobic, pleated PTFE membrane rated at 0.2µm absolute for sterile air filtration • Materials of construction conform to USP Class VI biological tests for plastics • High surface area and high voids volume combine to offer exceptional flow rates and extended service life • Fully validated by aerosol and liquid bacterial challenge • Filters are integrity testable by all methods including Water Intrusion Test • FCVA Series is fully retentive to aerosolized Brevundimonas diminuta (ATCC 19146) bacteria when challenged with a total of 2x109 cfu over a 1-hr test at the rated flow of the cartridge. • Conformance to the requirements for the non-fibre releasing filters as laid down in the U.S. Food and Drug Administration Regulations 12CFR211.72 and 210.3(b), (6). CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD). . . . . . . . Length (in). . . . . . . . . . . 2.6 5, 10, 20, 30 Cartridge . . . . . . . . . . . . Membrane. . . . . . . . . . . Seals . . . . . . . . . . . . . . . Polypropylene caps, core and cage Hydrophobic PTFE Silicone o-rings Maximum Temperature . . . . . . . . . . . . . Maximum Differential Pressure @ 20°C Air Filtration Rating . . . . . . . . . . . . . . . . Toxicity. . . . . . . . . . . . . . . . . . . . . . . . . . 50˚ C 50 psig 0.02 µm Absolute All components conform to the Biological Safety Standards identified in USP <88> Biological Reactivity to Class VI-121˚C levels ASTM F838-83 Liquid Bacterial Challenge Fully retentive to both Aerosol Bacteria and Phage Challenge Materials Operating Parameters Validation . . . . . . . . . . . . . . . . . . . . . . . . Sanitizing Agents Sterilization . . . . . . . . . . . . . . . . . . . . . . ................... Can be insitu steam sterilized up to 180 times at 142˚C Chlorine, hydrogen peroxide Micron Rating . . . . . . . . Minimum Bubble Point (psi) Pressure Decay Test Pressure (psi) Maximum Diffusional Flow (ml/min) 0.2 µm liquid rating 14.5 11.6 8.5, 18, 36, 54 Integrity Test @ 20˚C ORDERING INFORMATION Catalog Number and Description FCVA. . . . . . . . . . . . . . . Filter Cartridge Vent PTFE X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end 7 = 2-226 o-rings w/locking tabs/spear end XX . . . . . . . . . . . . . . . . . Length (in): 05 = 5, 10 = 10, 20 = 20, 30 = 30 S2 . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 µm To figure your order number, replace the X with one of the numbered or lettered options beside it. NOTE: These filter cartridges should not be used as a combination air vent/water overflow device. NOTE: Not all part number combinations are available; consult Technical Support for assistance. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 62 CARTRIDGE FILTER - VENT FILTER VP Series Hydrophobic PTFE Validated Media Vent Filter Cartridge • Composed of a pleated, hydrophobic, PTFE, Teflon® membrane rated at 0.2 µm absolute for sterile air filtration, storage tank venting applications • Filter components meet the criteria of the USP Class VI biological test for plastics • These filters feature minimal pressure loss, long service life due to high void volume, and can be repeatedly steam sterilized or autoclaved • Bacterial Growthrough - Prevention of bacterial grownthrough by Brevundimonas diminuta for at least 21 days @ a challenge level ≥ 1 x 107 CFU/cm2 CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) Length (in) ................ ................ 2.6" (6.6 cm) 10, 20, 30 Cartridge Media Seals ................ ................ ................ Polypropylene caps, core and cage Hydrophobic Teflon® PTFE Silicone o-rings and gaskets Materials Operating Parameters Maximum Temperature . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 21°C . . Air Filtration Rating ................ Toxicity ................ Virus Aerosol Retention . . . . . . . . . . . . . . . Sanitizing Agents Integrity Test ................ ................ Bubble point @ 23˚C . . . . . . . . . . . . . . . . Nitrogen Diffusion @ 23˚C . . . . . . . . . . . . . Ambient Air 72 psi (5.0 bar) 0.2 µm Absolute Non-toxic by USP Class VI biological test for plastics Retention of a worst case challenge of the model bacteriophage Φ X–174 was complete at challenge levels at 108 to 1010 virus particles at 1400 sL/min (50scfm) after 50 steam sterilization cycles of 30 minutes at 145˚C. Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121°C under no load conditions. ≥ 13 psig (≥ 900 mbar) nitrogen with 60/40% IPA/Water ≥ 45 mL/min @ 690 mbar (10 psig) in 60/40% IPA/Water ORDERING INFORMATION Catalog Number and Description FCVP . . . . . . . . . . . . . . Filter cartridge vent polysulfone X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end 7 = 2-226 o-rings w/locking tabs/spear end XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30 S2 . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 µm To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. NOTE: These filter cartridges should not be used as a combination air vent/water overflow device. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 63 CHEMICAL FEED SYSTEMS AND ACCESSORIES Antiscalant, Coagulants, Dechlorination, Chlorination, Cleaner and Disinfectants Siemens offers pretreatment chemical addition products to maintain the performance of Reverse Osmosis (RO) systems, inhibiting fouling and scaling of RO membranes. Siemens Technical Specialists can assist you in choosing the proper product and applying these products correctly. Pretreatment chemical addition can be a cost-effective alternative to other methods of controlling feedwater chemistry. Antiscalants/Antifoulants prevent scaling of RO membranes, as well as reduce the rate of colloidal fouling, including hardness and silica. Coagulants injected before multimedia filters and directly into clarifiers to improve filtration of silt, turbidity, particulate matter and colloids. Dechlorination chemicals include sodium sulfite, sodium bisulfite, or sodium metabisulfite to remove chlorine prior to reverse osmosis systems. Chlorination kills and controls bacteria in pretreatment systems. Cleaner chemicals with either low or high pH properties remove ionic and organic foulants in the RO membrane. Disinfectant chemicals, such as peroxyacetic acid and hydrogen peroxide formulations, are used to sanitize the reverse osmosis systems. Standard Chemical Feed System: Pre-kitted Chemical feed systems are pre-kitted units with ratings of 1, 2, 4 or 5 gph, and consist of a metering pump, a storage tank with a liquid level switch and suction tube shield. • Available with or without a flow pulsar. • A flowmeter pulsar is optionally available. SYSTEM SPECIFICATIONS Pump head . . . . . . . . . Fittings . . . . . . . . . . . . . Valve Balls . . . . . . . . . . Liquifram . . . . . . . . . . . Seal Rings . . . . . . . . . . Connections. . . . . . . . . Output . . . . . . . . . . . . . Tank . . . . . . . . . . . . . . . Tank Size (gallons) . . . Liquid Level Switch . . . Flow Meter Pulsar . . . . Electrical . . . . . . . . . . . PVC Polypropylene Ceramic Teflon® face Teflon® Liquid end no. 72S–0.5" tube Liquid end no. 92S–0.375" tube 100 psi Polyethylene 35 for 1 gph, 50 for 2.5 and 4 gph Polypropylene housing; PVC float tube; polypropylene float Body–bronze; Rotor–polypropylene 115 V/60 Hz ORDERING INFORMATION Catalog No. ZWCF40000 ZWCF400FM ZWCF25000 ZWCF250FM ZWCF10000 ZWCF100FM Description 4 gph chemical feed system w/outflow meter 4 gph chemical feed system w/flow meter 2.5 gph chemical feed system w/outflow meter 2.5 gph chemical feed system w/flow meter 1.0 gph chemical feed system w/outflow meter 1.0 gph chemical feed system w/flow meter ORDERING INFORMATION Contact Technical Support at (800) 875-7873 ext. 5000 for assistance in sizing your system, choosing the proper chemical and determining the quantity of chemical required. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 64 CHEMICAL FEED SYSTEMS AND ACCESSORIES - CHEMICAL FEED SYSTEMS Standard ChemFeed Systems: Grundfos® Pumps Siemens offers standard dual-pump feed systems covering common chemical applications. The table below lists chemicals and pump configurations available for Grundfos® Electronic Metering Pumps. All chemical feed skids are completely assembled and engineered for easy installation and operation. Ordering Information Catalog # Model # Description Capacity SP10701904 GR-16-100-C-V 15.84 GPD SP10701999 GR-48-100-C-E Two pump skid with common inlet/discharge. 100ml Calibration Cylinder Two pump skid with common inlet/discharge. 100ml Calibration Cylinder Two pump skid with common inlet/discharge. 250ml Calibration Cylinder Two pump skid with common inlet/discharge. 250ml Calibration Cylinder Two pump skid with common inlet/discharge. 250ml Calibration Cylinder * w/ Diaphragm Valves and Auto-Vent for Hypo SP10701987 SP10701997 SP10701907 GR-48-100-C-V GR-118-250-C-V GR-118-250-C-V-D 47.52 GPD 47.52 GPD 117.6 GPD 117.6 GPD Material of Construction CPVC / Viton® CPVC/ Viton® CPVC/EPDM CPVC/ Viton® CPVC/ Viton® Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents CHEMICAL FEED SYSTEMS AND ACCESSORIES - CHEMICAL FEED SYSTEMS Standard ChemFeed Systems: LMI® Pumps Siemens offers standard dual-pump feed systems covering common chemical applications. The table below lists chemicals and pump configurations available using LMI® Electronic Metering Pumps. All chemical feed skids are completely assembled and engineered for easy installation and operation. Ordering Information System Specifications Chemical Catalog # Output / PSI Pump Head Sodium Bisulfite SB-10-100 SB-24-100 SB-60-250 SB-96-500 10 GPD / 140 PSI 24 GPD / 110 PSI 60 GPD / 100 PSI 96 GPD / 100 PSI SH-10-100 SH-10-100 SH-60-250 SH-96-500 Connections Output Control Electrical Skid Sodium Bisulfite: PVDF /TFE Polymer: PP/TFE Bleach:PVDF/TFE Alum: PVDF/TFE Potassium Permanganate: PVDF/TFE Caustic: PVDF/TFE Hydrochloric Acid: PVDF/TFE Sulfuric Acid: PVDF/TFE Anti-Scalant: PVDF/TFE 1/2" CPVC 10,GPD / 140PSI 24GPD / 110PSI 60GPD / 100PSI 96GPD / 100PSI Polymer Bleach Alum Manual or 4-20 mA 120VAC / 60Hz / 1Ph Potassium Permanganate 24" x 36" PE Base Caustic Hydrochloric Acid Sulfuric Acid Anti-Scalant POLY-10-100 POLY-24-100 POLY-60-250 POLY-96-500 AL-10-100 AL-24-100 AL-60-250 AL-96-500 PP-10-100 PP-24-100 PP-60-250 PP-96-500 CAU-10-100 CAU-24-100 CAU-60-250 CAU-96-500 HCA-10-100 HCA-24-100 HCA-60-250 HCA-96-500 SA-10-100 SA-24-100 SA-60-250 SA-96-500 AS-10-100 AS-24-100 AS-60-250 AS-96-500 Spare LMI Pump Catalog # Spare Parts Catalog # AA971-353SI AA951-393SI B921-393SI C921-363SI SP-SB-10 SP-SB-24 SP-SB-60 SP-SB-96 10 GPD / 140 PSI 24 GPD / 110 PSI 60 GPD / 100 PSI 96 GPD / 100 PSI AA971-353HI AA951-393HI B921-393HI C921-363HI SP-SH-10 SP-SH-24 SP-SH-60 SP-SH-96 10 GPD / 140 PSI 24 GPD / 110 PSI 60 GPD / 100 PSI 96 GPD / 100 PSI AA971-353SI AA951-393SI B921-393SI C921-363SI 10 GPD / 140 PSI 24 GPD / 110 PSI 60 GPD / 100 PSI 96 GPD / 100 PSI AA971-155HV AA951-85HV B921-85HV C921-75HV 10 GPD / 140 PSI 24 GPD / 110 PSI 60 GPD / 100 PSI 96 GPD / 100 PSI AA971-353SI AA951-393SI B921-393SI C921-363SI 10 GPD / 140 PSI 24 GPD / 110 PSI 60 GPD / 100 PSI 96 GPD / 100 PSI AA971-353SI AA951-393SI B921-393SI C921-363SI 10 GPD / 140 PSI 24 GPD / 110 PSI 60 GPD / 100 PSI 96 GPD / 100 PSI AA971-353SI AA951-393SI B921-393SI C921-363SI 10 GPD / 140 PSI 24 GPD / 110 PSI 60 GPD / 100 PSI 96 GPD / 100 PSI AA971-353SI AA951-393SI B921-393SI C921-363SI 10 GPD / 140 PSI 24 GPD / 110 PSI 60 GPD / 100 PSI 96 GPD / 100 PSI AA971-353SI AA951-393SI B921-393SI C921-363SI SP-POLY-10 SP-POLY-24 SP-POLY-60 SP-POLY-96 SP-AL-10 SP-AL-24 SP-AL-60 SP-AL-96 SP-PP-10 SP-PP-24 SP-PP-60 SP-PP-96 SP-CAU-10 SP-CAU-24 SP-CAU-60 SP-CAU-96 SP-HCA-10 SP-HCA-24 SP-HCA-60 SP-HCA-96 SP-SA-10 SP-SA-24 SP-SA-60 SP-SA-96 SP-AS-10 SP-AS-24 SP-AS-60 SP-AS-96 Spare Parts Kits include (1) Calibration Cylinder, (1) Ball Valve, (1) Pump Spare Parts Kit (Seals, Springs, Ball Checks & Diaphragm). LMI = Liquid Metronics, Inc. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 65 66 CHEMICAL FEED SYSTEMS AND ACCESSORIES - CHEMICAL FEED SYSTEMS Polymer Feed Systems PolyBlend® PB polymer feed systems provide optimum polymer activation and performance. The PB Series PolyBlend® systems are economical and easy to install and operate. The patent technology and offer proven performance make the PolyBlend® the benchmark in the industry. Ordering Information PolyBlend® PB Series Polymer Feed Systems Catalog # Water Flow Diaphragm Pump Rate GPH Output GPH PB16-0.4 16 0.4 PB100-1.0 100 1.0 PB200-2.0 200 2.0 At the center of the PolyBlend® PB Series polymer feed system is the patented multizone mixing chamber. The advanced design provides uniform dispersion energy at the moment of initial wetting. The high-energy mix prevents agglomerations and eliminates the need for extended mixing and aging by applying the right energy at the right time. The low energy zone continues to activate the hydrated polymer without destroying the fragile polymer chains. The result is maximum polymer activation and improved polymer performance. EZ ChemFeed Systems Siemens offers a variety of chemical feed and control systems to meet the requirements of harsh industrial applications. From simple EZ Series pump skids and accessories to complex systems, Siemens has the ChemFeed solution for your water treatment needs. Ordering Information Standard EZ Chemical Feed Systems & Accessories Catalog # Model # Description CFSEZ1 EZ-1 Pump System The EZ1 Pumps System is a skid-mounted chemical metering system designed for maximum reliability and convenience. The EZ1 package utilizes LMI® pumps providing a broad range of capabilities EZ1 Systems are typically used in water treatment programs to dose proper amounts of inhibitors, dispersants, biocides, as well as pH control chemicals and oxidants. The system comes complete and ready for service upon delivery CFSEZ2 EZ-2 Pump System The EZ2 Dual Pump Skid System is a skid-mounted chemical metering system designed to feed either one or two chemicals together or separately. The EZ2 package utilizes LMI® pumps providing a broad range of capacities and flexibility to handle a wide range of applications. EZ2 Systems are typically used in water treatment programs to dose proper amounts of inhibitors, dispersants, biocides, as well as pH control chemical and oxidants. CFSEZENCLOSURE EZ -Enclosure The EZ Enclosure is a high-quality NEMA 12 fiberglass enclosure, which is ideal for a number of chemical treatment applications. These units are used for dual biocide applications where containment is important. CFSDRUMSHELF EZ- Drum Shelf The EZ Drum Shelf is designed to secure a metering pump atop a metal or plastic 55-gallon drum. The unit, constructed of 1/2 inch PVC, prevents pumps from tipping over. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS Chem-Tech® Chemical Metering Pumps The Chem-Tech® pump combines proven degassing technology with the durability and dependability that has earned Chem-Tech® pumps the respect of water treatment professionals around the world. The result is a series of positive displacement diaphragm metering pumps that are totally self-priming and maintain their prime even in the most demanding water conditioning and water treatment applications. Ordering Information Chem-Tech Prime Performance™ Pumps Catalog # X015-XA-BAA8XXX X015-XA-BBA8XXX X024-XA-BAA8XXX X024-XA-BBA8XXX X030-XA-BAA8XXX X030-XA-BBA8XXX Catalog # Series CTP-A Simplex (Peristaltic Pumps) CTPA2HSA-PAP1-XXXXX CTPA2LSA-PAP1-XXXXX CTPA3HSA-PAP1-XXXXX CTPA3LSA-PAP1-XXXXX CTPA4HSA-PAP1-XXXXX CTPA4LSA-PAP1-XXXXX CTPA6LSA-PAP1-XXXXX CTPA6HSA-PAP1-XXXXX Series CTP-A Duplex (Peristaltic Pumps) CTPB2LSA-PAP1-XXXXX CTPB3LSA-PAP1-XXXXX CTPB4LSA-PAP1-XXXXX CTPB6LSA-PAP1-XXXXX Series CTP-AE Simplex (Peristaltic Pumps) CTPA2HEA-PAP1-XXXXX CTPA2LEA-PAP1-XXXXX CTPA3HEA-PAP1-XXXXX CTPA3LEA-PAP1-XXXXX CTPA4HEA-PAP1-XXXXX CTPA4LEA-PAP1-XXXXX CTPA6LEA-PAP1-XXXXX CTPA6HEA-PAP1-XXXXX Series CTP-AE Duplex (Peristaltic Pumps) CTPB2LEA-PAP1-XXXXX CTPB3LEA-PAP1-XXXXX CTPB4LEA-PAP1-XXXXX CTPB6LEA-PAP1-XXXXX Series CTP-D Simplex (Peristaltic Pumps) CTPD2HSA-PAP1-XXXXX CTPD3HSA-PAP1-XXXXX CTPD4HSA-PAP1-XXXXX CTPD6HSA-PAP1-XXXXX Series CTP-D Duplex (Peristaltic Pumps) CTPE2HSA-PAP1-XXXXX CTPE3HSA-PAP1-XXXXX CTPE4HSA-PAP1-XXXXX CTPE6HSA-PAP1-XXXXX GPH 15 15 24 24 30 30 PSI 100 100 100 100 100 100 Head & Fittings PSI Tubing 3.5 3.5 8 8 13 13 30 30 125 80 110 70 100 50 40 80 Norprene Norprene Norprene Norprene Norprene Norprene Norprene Norprene GPH 7 16 26 60 3.5 3.5 8 8 13 13 30 30 80 70 50 40 125 80 110 70 100 50 40 80 PVC / Hypalon PVC / Viton PVC / Hypalon PVC / Viton PVC / Hypalon PVC / Viton Norprene Norprene Norprene Norprene Norprene Norprene Norprene Norprene 80 70 50 40 Norprene Norprene Norprene Norprene 14 32 52 120 125 110 100 80 Norprene Norprene Norprene Norprene *Standard Duplex models are of like pressure and flow rate 125 110 100 80 KX100-BAA8 KX100-BBA8 KX100-BAA8 KX100-BBA8 KX100-BAA8 KX100-BBA8 Norprene Norprene Norprene Norprene 7 16 26 60 7 16 26 60 KOP Kit Catalog # Norprene Norprene Norprene Norprene Peristaltic Tubing Option. - FLURAN® Severe Environment Tubing The tubing option is the sixth position in the model number, which is coded as “H” or “L” in the standard CTP models. Standard tubing on all models is norprene. The FLURAN tubing option is not available on CTP-A/AE duplex models or on models with a max flow rate greater than 24 GPD. Max pressure rating with FLURAN tubing is 60 PSl. When ordering FLURAN tubing, replace the “L” or “H” in the model number with “F”. Pos. 5&6 CTP-A/AE Models CTP-D Models 2F 3 GPD 7 GPD 3F 8 GPD 16 GPD 4F 13 GPD 26 GPD BACK Chem-Tech Prime Performance™ Pumps The new Chem-Tech Prime Performance™ pump combines Pulsafeeder’s proven degassing technology with the durability and dependability that has earned Chem-Tech® pumps the respect of water treatment professionals around the world. The result is a series of positive displacement diaphragm metering pumps that are totally self priming and maintain their prime even in the most demanding water conditioning and water treatment applications. Pump sizes are 15, 24, or 30 GPD @ 100 PSI and driven by 115VAC motors. Series CTP (Peristaltic Pumps) The Series CTP offers a bold new look in reliability and value and is available in three control options offering feed rates up to 60 GPD (9.5L PH) with pressures to 125 PSI ( 8.6bar). The Series CTP-A includes a percentage dial for reliable operation and adjustable feed rates in 5-second increments. The Series CTP AE is a 100% fixed rate economy model with an off-on dial for applications requiring constant feed and easy use. Both Series CTP-A and Series CTP-AE models are available with optional 7-day timers for biocide feed or other timed applications. For applications requiring precise feed rates, the Series CTP-D offers digital control from 10% to 100% up to 60 GPD (9.5LPH). Adjustable in 1% increments, the Series CTP-D provides maximum control for demanding applications. Simplex and duplex head configurations are both available. Control Options The control option is the seventh position in the model number, which is coded as an “S” in the standard Series CTP-A / CTP-D and as “E” in the standard Series CTP-AE. When ordering one of the following options, replace the “S” or “E” with the appropriate control option code listed below. Position 7 Description T 7 Day Mechanical Timer (2 hr. increments) with Series CTP-A R 7 Day Mechanical Timer (2 hr. increments) with Series CTP-AE D 7 Day – 8 Event Electronic Timer (1 min. increments) with Series CTP-A / CTP-D C 7 Day – 8 Event Electronic Timer (1 min. increments) with Series CTP-AE Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 67 68 CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS LMI® Series Chemical Metering Pumps Series A, B and C LMI® Chemical Metering Pumps have been an industry standard for over 20 years. The familiar yellow and black pumps have a rugged, totally enclosed, chemically resistant housing for protection in the harshest environments. Encapsulated electronics and a rigid housing and stroke bracket ensure years of precise, repeatable performance. The Series P Metering Pump is designed for more economical chemical injection. The totally enclosed, chemically resistant housing and encapsulated electronics provide the performance and long life. Dual manual control of stroke speed and length and fixed speed versions are available for simple manual or on/off control. Ordering Information A Series B Series C Series P Series NOTE: Catalog # GPH PSI Head & Fittings AA141-155S AA151-95S AA151-392SI AA161-362SI AA171-352SI AA741-352SI AA751-392SI AA771-352SI AA941-352SI AA951-392SI AA971-352SI .58 1 1 2 .42 .42 1 .42 .58 1 .42 250 110 110 50 140 140 110 140 250 110 140 PP PP PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF B111-392SI B121-393SI B721-490SI B911-398SI B921-393BI C101-94S C111-75S C121-362BI C131-313BI C141-35T C701-94S C731-20S C771-20S C911-363BI C921-363BI C931-313SI P021-352BI P121-352SI P131-392SI P141-352SI P151-392BI P161-362BI P741-352BI P751-392BI P761-362BI 1.6 2.5 2.5 1.6 2.5 150 100 100 150 100 1.3 2.5 4 8 20 1.3 8 10 2.5 4 8 300 150 100 60 25 300 60 80 150 100 60 .21 .21 .42 .58 1 2 .58 1 2 150 150 110 250 110 50 250 110 50 S and SI suffix indicate 4-Function Valve BI suffix indicate Bleed Valve *Please contact Technical Support for additional pump selections Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK PVDF/PVDF PVDF/PVDF Acrylic/PVC PVC/PVC PVDF/PVDF PVC/PVC PP PVDF/PVDF PVDF/PVDF PP PVC/PVC Acrylic/PVC Acrylic/PVC PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF PVDF/PVDF Repair Kit Part Catalog # SP-U9 SP-U1 RPM-392 RPM-362 RPM-352 RPM-352 RPM-392 RPM-352 RPM-352 RPM-392 RPM-352 RPM-392 RPM-393 RPM-490 RPM-398 RPM-393 SP-U1 SP-U2 RPM-362 RPM-313 SP-U6 SP-U1 SP-20 SP-20 RPM-363 RPM-363 RPM-313 RPM-352 RPM-352 RPM-392 RPM-352 RPM-392 RPM-362 RPM-352 RPM-392 RPM-362 Control Options: Type “9” control is designed for easy integration into chemical feed systems. The stroke rate may be controlled manually or by an external signal generated by a flowmeter, controller, transmitter, PLC or other device. Divide or multiply a digital (pulse) input or program a response to a milliamp (4-20, 0-20, 20-4, 20-0) input. The optional DigiPulse Flow Monitor verifies chemical flow and provides an alarm output. Type “7” control is designed for more economical systems. The stroke rate may be controlled manually or by a digital input. The optional Micropace Control Modules enable the user to divide or multiply a digital input or respond directly and proportionally to a 4 - 20 milliamp input. Type “1” control is designed for accurate chemical feed where manual or on/off control is all that is required. Dual manual control of stroke speed and stroke length is provided. LMI Part # System example: AA151-392SI AA= Pump Series 1= Control Code 5= Output Code 1= Voltage Code 3= LiquiPro Series 9= Head Size 2= Material S= Valve Code I= Tubing Code Section Table of Contents CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS PULSAtron® Chemical Metering Pumps Siemens offers a vide variety of PULSAtron® metering pumps. After more than 10 years of product evolution, the PULSAtron® standard continues to set the pace with the recent introduction of the DG/5FV degas valve. PULSAtron® pumps can successfully handle a variety of gaseous solutions previously relegated to other metering technologies. The Pulsatron® family consists of six unique Series with 76 flow and pressure ranges to choose. Most models include our standard Bleed Valve assembly, foot strainer, injection valve and tubing. No matter what your application, choose the PULSAtron® metering pump that is right for you. ORDERING INFORMATION Series MP Series E Plus Series E Series A Plus Series C Plus Series C Catalog # LMK2TA-KTC1-500 LMB2TA-KTC1-500 LMD3TA-KTC1-500 LMF4TA-KTC1-500 LMH4TA-KTC1-500 GPH 3 5 11 20 40 PSI Head & Fittings KOP Kit Catalog # 300 250 250 250 250 PVDF PVDF PVDF PVDF PVDF K2KTC1 K2KTC1 K3KTC1 K4KTC1 K4KTC1 LPA2SA-KTC1 LPB3SA-KTC1 LPD4SA-KTC1 LPG4SA-KTC1 LPH5SA-KTC3 LPH6SA-KTC3 LPH7SA-KTC3 LPH8SA-WTCB 6 12 21 42 75 120 240 500 150 150 150 150 150 100 35 20 PVDF PVDF PVDF PVDF PVDF PVDF PVDF PVDF K2KTC1 K3KTC1 K4KTC1 K4KTC1 K5KTC3 K6KTC3 K7KTC3 K8WTCB LB02SA-VTC1 LB03SA-VTC1 LB04SA-VTC1 LB64SA-VTC1 6 12 22 30 150 150 100 100 PVC PVC PVC PVC K2VTC1 K3VTC1 K4VTC1 K4VTC1 LPB2SA-KTC1 LPD3SA-KTC1 LPF4SA-KTC1 LPH4SA-KTC1 LD02SA-VTC1 LD03SA-VTC1 LD04SA-VTC1 LD54SA-VTC1 LC02SA-VTC1 LC03SA-VTC1 LC04SA-VTC1 LC54SA-VTC1 5 11 20 40 6 12 22 30 6 12 22 30 250 250 250 250 80 80 80 80 80 80 80 80 PVDF PVDF PVDF PVDF PVC PVC PVC PVC PVC PVC PVC PVC K2KTC1 K3KTC1 K4KTC1 K4KTC1 K2VTC1 K3VTC1 K4VTC1 K4VTC1 K2VTC1 K3VTC1 K4VTC1 K4VTC1 Series MP The Series MP is a true microprocessor controlled instrument for precise and accurate metering control. Series MP include automatic control via 4-20mA or 20-4mA inputs, external pace with stop feature and 16-character LCD display. Series E Plus The Series E Plus offers manual control over stroke length and stroke rate as standard with the option to choose between 4-20mA or external pace inputs for automatic control. Series E The Series E offers manual function controls over stroke length and stroke rate providing a turn down ratio 100:1. Series A Plus The Series A Plus offers manual control over stroke length and stroke rate as standard with the option to select external pace for automatic control. Series C Plus Like the Series A Plus, the Series C Plus offers manual control over stroke length and stroke rate as standard with the option to select external pace for automatic control. Series C The Series C offers manual on-line stroke length adjustment with fixed stroke rate. Optional control features include external pace a choice between momentary on/off switch for priming the pump or a toggle on/off switch for manual override of all control functions. NOTE: The -500 indicate 5-Function Bleed Valve *Please contact Technical Support for additional pump selections Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 69 70 CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS PULSAtron® Plus Chemical Metering Pumps Water treatment professionals are under constant pressure to understand new chemical treatment programs. While some applications require sophisticated control systems with multi-parameter inputs and outputs, many installations can be satisfied with a simpler approach. The PULSAtron® Plus is the ideal choice when basic control is all that is required. PULSAtron® Plus is a unique family of products that combine basic control functions into a PULSAtron® pump, eliminating the need for separate pieces of equipment. Available across a full range of pump capacities and pressure ratings, each member of the PULSAtron® Plus family incorporates a variety of control features that target specific applications. ORDERING INFORMATION Series CW Series CL Series WT Series T7 Series ET Catalog # GPH PSI Head & Fittings Description LWO2RAVHC12XXXX LWO3RAVHC12XXXX LWO4RAVHC12XXXX LW64RAVHCI2XXXX .25 .5 1 1.25 150 150 100 100 PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon LLO2RAVHCT2XXXX LLO3RAVHCI2XXXX LLO4RAVHC12XXXX LL64RAVHC12XXXX .25 .5 1 1.25 150 150 100 100 PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon Rising Set Point, ll5V, .25” ID Tubing, SS Sensor w/ 8.5’ Cable, No Flow Switch LQ02XAVHClXXXXX LQ03XAVHCTXXXXX LQ04XAVHCIXXXXX LQ64XAVHClXXXXX .25 .5 1 1.25 150 150 100 100 PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon LTB2SAVHCTXXX LTF4SAVHCIXXX LTH4SAVHCIXXX LTA2SAVHC1XXX LTB3SAVHClXXX LTD4SAVHClXXX LTG4SAVHClXXX LTHSSAVHC1XXX LTA3SAVHC1XXX LTB4SAVHC1XXX LTE4SAVHC1XXX LTH6SAVHC1XXX LTH7SAVHCIXXX LTH8SAVHClXXX .21 .85 1.70 .25 .50 .90 1.75 3.15 .50 1 1.85 5 10 21 250 250 250 150 150 150 150 150 100 100 100 100 35 20 PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon LCl3BAVHClXXX LCl4BAVHCTXXX LC64BAVHC1XXX LC44BAVHClXXX .5 1 1.25 2 100 100 100 50 PVC/Hypalon PVC/Hypalon PVC/Hypalon PVC/Hypalon Rising Set Point, ll5V, .25” ID Tubing, SS Sensor w/ 8.5’ Cable, No Flow Switch 115V, .25" Tubing, No Flow Switch 115V, .25" Tubing Manual On/Off, 115V, .25" Tubing Series CW: Conductivity Control with Water Meter Feed The Series CW provides conductivity control with a water meter feed. Bleed is initiated when the conductivity level reaches the user specified set point. Chemical feed is initiated and controlled by input from a water meter. The Series CW includes a solenoid actuated metering pump, conductivity sensor, bleed relay and a dry contact input for water meter control. Series CL: Conductivity Control with Limit Timer The Series CL provides conductivity monitoring and control with a Limit Timer that controls the feed time. Tower feed and bleed are initiated when the conductivity levels reaches the user-specified set point. The programmable limit timer allows the operator to specify the maximum pumping time for the feed cycle. The Series CL includes a conductivity sensor, bleed relay and a userprogrammable limit timer. Series WT: Feed & Bleed Control with Water Meter Input The Series WT provides feed and bleed control with a water meter input. The feed and bleed cycles are initiated and controlled by input form the water meter. Separate programmable pulse timers control the pump and bleed relay. The Series WT includes a flow input, water meter input and two programmable pulse timers. Series T7: Feed Control with 7 Day Timer The Series T7 was designed to control the feeding of biocide or other product that must be fed on a timed schedule. The Series T7 includes a 7-day programmable timer and clock with the ability to control up to 8 on/off cycles per day. Each timed event can be set to run any day of the week on a 7-day cycle. The feed cycle is initiated and controlled by the user programmable timer. Series ET: Feed Control with Water Meter Input The Series ET provides feed control with input from a water meter input. When the count exceeds a set value (either 1 or 10), the pump starts. The pump will continue to run for an adjustable time period. The Series ET includes both input and output water meter connections at the front panel. The output connection provides an isolated dry contact output of the water meter contact to operate additional pumps or timers off the same water meter. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS Wallace & Tiernan® Metering Pumps CHEM-AD® XL Diaphragm Metering Pump The CHEM-AD® XL range of metering pumps are mechanically actuated diaphragm dumps with integrated controls capabilities. Capacities up to 238 GPH Key Controls & Features • On-off Button • Mechanical Stroke Length Control • Stroke Frequency Control, Level Switch Input (low level and empty) • Power Cord and Plug up to 3.5 GPH • External Analog Scalable Input (0/4-20 mA), (20-0/4mA) • Input Signal Scaling, External Pulse Input • Remote On / Off • Batch Mode & Pulse Storage • Alarm Output & Stroke Pulse Output • Membrane Touch Pad Operator Interface • Flow Monitoring (External OGM required) • Integral Back-lit Digital Display • Password Protection, Capacity display, Flow Totalizing Ordering Information CHEM-AD® XL Diaphragm Metering Pumps with Integrated Controls Catalog # GPH PSI Description CM1A4E60KFC9931 0.44 120 Automatic E60 Speed Controls with degas system, PVDF Liquid Ends, Ceramic Ball, Viton® O-rings CM1B4E60KFC9933 1.36 120 Automatic E60 Speed Controls, PVDF Liquid Ends, Ceramic Ball, Viton O-rings CM1B6E60KFC9933 3.5 60 CM1C1E60PFC9936 5 120 Automatic E60 Speed Controls, PP Liquid Ends, Ceramic Ball, Viton O-rings CM1C3E60PFC9936 17 120 CM1C5E60PFC9939 38 35 CM1D1E60PFC9939 44 120 Accessories Suction Lance: Includes Dual Level Switches, Foot Valve, and Strainer AAB5197 Suction Lance, used in Series A & B all sizes AAB5206 29.5" long, PVC Pipe, Viton® O-rings, Glass Ball 44.3" long, PVC Pipe, Viton O-rings, Glass Ball AAC2411 Thrust Piece – one (1), required per suction lance with Series A Use DUO hose to connect to suction valve. AAC2423 Adapter – one (1), required per suction lance with Series B Use 3/8" OD x 1/4" ID tubing to connect to suction valve AAB7732 Suction Lance, used in Series C1, C2 & C3 (5 to 17 GPH) 55.1" long, PVC Pipe, Viton O-rings, Glass Ball AAC8111 Connection Set – two (2), required per suction lance with Series C Use 1/4" OD x 3/8" ID tubing to connect to the suction valve Multifunction Valve (Functions include – Back Pressure, Pressure Relief, Draining & Priming.) AAB5248 Multifunction Valve, used in Series B all sizes (0.44 to 3.5 GPH) Back Pressure Range, 15 – 75 PSI, PVDF Housing, Viton® O-rings. AAC5663 Thrust Piece – two (2) required per valve with Series B AAB6973 Multifunction Valve, used in Series C1, C2 & C3 (5 to 17 GPH) Back Pressure Range, 15 – 75 PSI, PVDF Housing, Viton O-rings. AAC2513 Adapter, two (2) required per valve on Series C1, C2 & C3 Rigid piping installation AAC8111 Connection Set – two (2) required per valve on Series C1, C2 & C3 Flexible tubing connection. AAB7003 Multifunction Valve, used in Series C4 & C5 (25 to 38 GPH) Back Pressure Range, 15 – 75 PSI, PVDF Housing, Viton O-rings. AAC8132 Adapter, two (2) required per valve on Series C4 & C5, Rigid piping installation Wall Mount Bracket AAC7594 Wall Mounting Bracket (ABS) for Series A, B & C Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 71 72 CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS Wallace & Tiernan® Metering Pumps ENCORE® 700 Diaphragm Metering Pumps The Encore® 700 Diaphragm Metering Pump combines the robustness of hydraulic pump with CONTROL FLEXIBILITY diaphragm pumps with the unparalleled economy, simplicity, and serviceability of a mechanical pump. The Encore® 700 pump is engineered to handle industrial and municipal metering applications in water and wastewater treatment, swimming pools, food processing, chemical processing, brewing and distillation, and agriculture. • Non-loss-motion variable eccentric stroke adjust mechanism renders efficiency, longevity, and reliability, as well as a smooth discharge pattern. • Precision-engineered liquid ends meter mild solutions, aggressive chemicals, high-viscosity polymers, and slurries with greater efficiency than conventional liquid ends. • Clear PVC cartridge valves for fast service with no piping disturbances and built-in visual indication of operation. • Premium composite diaphragm design ensures high metering accuracy, even at varying discharge pressures. Ordering Information Encore® 700 Diaphragm Metering Pump Catalog # PSI PVC Head / PTFE Diaphragm / Hypalon O-ring / Manual Control AAC1751 GPM 5 175 1/4 HP, 110VAC 1PH MOTOR AAC1757 24 175 1/4 HP, 110VAC 1PH MOTOR AAC1763 45 150 AAC1769 77 130 AAC1775 180 75 3/4 HP, 110VAC 1PH MOTOR For higher capacities and options consult factory. Additional metering pumps and water treatment accessories from leading manufactures are available. Contact Siemens Water Technologies for a complete list of options. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS Wallace & Tiernan® Metering Pumps Chemtube® PPS Peristaltic Pumps In the industrial marketplace, the Chemtube® PPS hose pumps are suitable for metering virtually any chemical to the point of application. Reliable feed rates are maintained in either continuous or intermittent duty cycles. There are many industrial applications for the Chemtube® PPS Hose pumps that go beyond our traditional metering pump capabilities. Chemtube® PPS pumps are ideal for, • Multiphase fluids • Shear Sensitive products & high viscosity products • Slurries & abrasive products with high solid contents • Highly corrosive products • High Suction Lift conditions • Self-priming design which will not air-lock Ordering Information Chemtube® PPS :S Series Pump Catalog # GPH CPS5B3GRP 2.2 CPS10B3GRP 7.0 PSI RPM Hose and Connection Material Repair Kit Part No. Hose: AAC7676 Repair Kit: AAC7931 25 Natural Rubber and PVC Connections 90 CPS16B3GRP 25 CPS26B3GRP 115 CPS5B3GHP 2.2 CPS10B3GHP 7.0 Hose: AAB7676 Repair Kit: AAC7931 Hose: AAB7691 Repair Kit: AAC7934 Hose: AAB7706 Repair Kit: AAC7937 22 Hose: AAC1799 Repair Kit: AAC7931 25 Hypalon Hose and PVC Connections 90 CPS16B3GHP 25 CPS26B3GHP 116 Hose: AAC1799 Repair Kit: AAC7931 Hose: AAC1802 Repair Kit: AAC7934 Hose: AAC1805 Repair Kit: AAC7937 22 Note: 1: All Chemtube® PPS models include ,S Series Pump with 5/10/16/26 mm hose, Variable Frequency Drive with NEMA 4X enclosure, 230 VAC/60Hz/3Ph, Inverter Duty Motor 230 VAC/60Hz, PVC connections, Natural Rubber Hose or Hypalon Hose, Leak Detector, One spare hose, Two year warranty excluding hose. 2: Refer to chemical compatibility chart for Hose material selection. Consult factory for special requirements. 3: For higher capacities and options consult factory. Accessory required for Chemtube® PPS Hose Pumps Pulsation Dampener (max 150 PSI ) Pump Model No. Catalog # Body and Diaphragm Material Connection Size S Series – S5 AAB7874 S Series – S10 AAB8657 S Series – S16 AAB8858 3/4” NPT (F) S Series – S26 AAB8876 1” NPT (F) 1/2” NPT (F) PVC / Hypalon Pressure Relief Valve (10 – 150 PSI) S Series S5, S10, S16, S26 AAB8816 PVC / PTFE / EPDM 1/2” NPT (F) Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 73 74 CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS Instrumentation & Controls Siemens offers a wide selection of instrumentation and control for cooling water and process water applications. Whether you need to control pH, ORP, conductivity, or more, Siemens has a controller or monitor to fit the application. TMS-561 Turbidimeter Depolox® 3 plus The TMS 561 Turbidimeter is specifically designed for continuous on-line measurement of turbidity in filtered or raw water in municipal and industrial water treatment plants, as well as final effluent in wastewater applications. Utilizing an EPA-approved, reusable, primary standard, routine calibration is fast and inexpensive. For poor-quality water, an ultrasonic, self-cleaning system is available to reduce maintenance. An optional data acquisition system and software package allows networking of up to 255 turbidimeters into a single computer. The software provides graphical trending, alarms, and filter analysis. TMS-561 Turbidimeter Catalog # Light TMS-561 BW TMS-561 BR TMS-561 CW TMS-561 CR TMS-561 DW TMS-561 DR White Infrared White Infrared White Infrared Range 0-1000 NTU 0-1000 NTU 0-100 NTU 0-100 NTU 0-1000 NTU 0-1000 NTU Ultrasonic Cleaning N/A N/A Standard Standard Standard Standard The Depolox® 3 plus residual analyzer continuously measures free or total (combined) chlorine in drinking water applications. Utilizing proven and universally accepted amperometric measurement technology, the Depolox® 3 plus analyzer directly measures chlorine residuals and provides a 4- 20 mA output signal for control or recording purposes. Integral alarm relays are included. The Depolox® 3 plus analyzer is also available in a dual input arrangement for measuring pH or fluoride, along with chlorine. *Please contact Technical Support for Depolox® analyzer options Ultrameter™ Series Instruments While priced like affordable single-parameter instruments, the Ultrameter™ does the job of three, four or even six instruments. All Ultrameter™ models deliver performance of ±1% of reading (not merely full scale). This high level of accuracy has been achieved through advanced fourelectrode conductivity cell technology, a unique pH/ORP sensor and powerful microprocessor-based circuitry. With displayed values of up to 9999, the full four-digit LCD ensures resolution levels never before possible in such affordable instruments. Ultrameter™ Instruments Catalog # Mode # METMYRNL4P 4PII METMYRNL6P 6PII Description Conductivity, TDS, Resistivity & Temperature Conductivity, TDS, pH, Resistivity, Temperature & ORP Contact Technical Support for additional information on our entire chemical feed and control offerings including: • Gas Feed Systems • Dry Feed Systems • On-Site Electrochlorination • Liquid Metering Systems • UV Systems • Custom Chemical Feed Systems • Analytical Instrumentation • Chemical Induction Systems • Flow Measurement & Control Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS Instrumentation & Controls (continued) Siemens offers a wide selection of instrumentation and control for cooling water and process water applications. Whether you need to control pH, ORP, conductivity, or more, Siemens has a controller or monitor to fit the application. Strantrol® 916 Controller Series Strantrol® Feed Verification Controller (FVC Series) The Strantrol® FVC provides accurate and reliable dosing measurement for a wide selection of metering pumps. The Strantrol® FVC controls and verifies the liquid chemical feed rate of actual chemical dispensed. A proportional feedback signal changes the stroke rate of the pump compensating for changes in pump output. Strantrol® Feed Verification Controllers Catalog # Min GPH Max GPH FVC-1.6 .079 1.58 FVC-16 1.58 15.85 FVC-32 3.17 31.7 FVC-63 6.34 63.4 FVC-158 15.85 158.5 FVC-317 31.7 317.0 Strantrol® 916P Controller The Strantrol® 916P Controller accurately and reliably maintains pH and conductivity control in industrial process water and cooling water applications. The 916P Controller combines innovative sensor technology with unique control schemes to offer an unequaled solution for industrial water treatment applications. Strantrol® 916O Controller The Strantrol® 916O Controller is configured for High Resolution Redox® sensing and conductivity control, which can dramatically improve disinfection of industrial process water and cooling water applications. Strantrol® 916 Controllers Catalog # Description 916P Conductivity / pH Controller System 916O Conductivity / ORP Controller System Strantrol® 885, 886 and 887 Controllers The Strantrol® 885, 886 and 887 series of controllers offer the reliability and precision that only comes with a Strantrol® product. These single channel controllers are available for ORP, pH or conductivity monitoring and control. Strantrol® 88X Controllers Catalog # Description Strantrol 885 Conductivity / Temperature Controller Strantrol 886 pH Controller Strantrol 887 High Resolution Redox® (ORP) Controller LMI® Controllers LMI® controllers are simple to setup and operate. All wiring and connections are included. Choose form pH, conductivity or ORP controllers for a variety of applications. LMI® Controllers Catalog # DC-5500 DC-4000 DC-4500 DP-5000 DR-5000 BACK Description Conductivity Controller for Cooling with Biocide Timers & Remote Communications Conductivity Controller for Cooling or Boiler (Bleed & Feed) Conductivity Controller for Cooling with Biocide Timers pH Controller ORP Controller Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 75 76 CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS PULSAtrol® Series The PULSAtrol® series economical and reliable controllers are easy to use and require minimum maintenance. Ordering Information MC9000 Series Controllers Catalog # MTC1PTXXXX MC9200 Series Controllers MC9210XXXXXX MC9220XXXXXX MC9230XXXXXX MC9300 Series Controllers MC9310XXXXXX MC9320XXXXXX MC9330XXXXXX MC9500 Series Controllers MC9510XXXXXX MC9520XXXXXX MC9530XXXXXX MC9540XXXXXX MC9550XXXXXX MC9560XXXXXX MC9570XXXXXX Description Prewire, 115VAC, with sensor tee Conductivity Control pH Control Conductivity and pH Control Conductivity Control pH Control Conductivity and pH Control Conductivity Control Conductivity and ORP Control Conductivity and pH Control Conductivity, make-up conductivity and pH Control Conductivity (with make-up), pH and ORP COntrol Dual Conductivity for open loop (tower) and closed loop (chiller) Dual Conductivity for dual cooling tower systems PULSAtrol® MC9000 Series Controllers The PULSAtrol® 9000 Series cooling tower controllers offer the most popular features as standard without compromising flexibility. All controllers come standard with a complete flow assembly mounted to a polypropylene backboard. MC9200 Series The MC9200 Series includes as standard, a pre-wired selectable timer, alarm output relay, dry contact alarm output and water meter totalizer. Options available include up to two 28-day biocide timers, single or dual 4-20mA outputs, communications and agency approvals (Contact factory for options). MC9300 Series The MC9300 Series includes as standard, four taggable timers, two water meter totalizers user configured as dry contact or hall effect, dry contact alarm relay and alarm output relay. Options include two 4-20mA outputs, conduit connection for power and relays, communications, language and agency approvals (Contact factory for options). MC9500 Series The MC9500 Series includes as standard, four taggable timers, two water meter totalizers user configured as dry contact or hall effect, four drum level inputs, dry contact alarm relay and alarm output relay. Options include two 4-20mA outputs, conduit connection for power and relays, communications, language and agency approvals (Contact factory for options). Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS Boilers PULSAtrol® Series Siemens now offers the PULSAtrol® Series of boiler control instrumentation. These economical and reliable controllers are easy to use and require minimum maintenance. Ordering Information MB9200 Series Boiler Controllers Catalog # MB9210XXXXX MB9220XXXXX MB9300 Series Boiler Controllers MB9210XXXXX MB9220XXXXX MB9600 Series Boiler Controllers MB9610XXXXXX MB9620XXXXXX MB9630XXXXXX MB9640XXXXXX Description Conductivity Control Dual Conductivity Control Conductivity Control Dual Conductivity Control Conductivity Control Dual Conductivity Control Triple Conductivity Control Conductivity Condensate / pH Control MB9200 Series The MB9200 Series includes as standard, two selectable timers, alarm output relay, dry contact alarm output, water meter totalizer, stainless steel sensor and mounting hardware for each boiler. Options include single or dual 4-20mA outputs, communications and agency approvals (Contact factory for options). MB9300 Series The MB9300 Series includes as standard, four selectable timers, alarm output relay, dry contact alarm output, two water meter totalizers and temperature compensated stainless steel sensors. Options include single or dual 4-20mA outputs, communications, language and agency approvals (Contact factory for options). MB9600 Series The MB9600 Series includes as standard, three or four selectable timers, two water meter totalizers user configured as dry contact or hall effect, four single point drum level inputs, dry contact alarm relay, alarm output relay and temperature compensated stainless steel sensors. Options include up to four 4-20mA inputs and outputs, communications, language and agency approvals (Contact factory for options). Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 77 78 CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS Vision Series Process Control Instrumentation Siemens now offers the Vision Series of process control instrumentation. The Vision Series product line is designed to handle a multitude of applications and is modular and expandable. The innovative use of USB technology makes these units customizable. Soft keys allow for easy programming and flexibility. Custom Control Package Design Procedure 1. Start by selecting a UV or LV controller. 2. Select the desired IntelliSense package. 3. If ordering a LV unit and more than three USB inputs/outputs are required, select a USB Hub. Please contact the factory for application review and design assistance. 4. If ordering a LV unit and more than four relays are required, select a Relay Expansion Box. Please contact the factory for application review and design assistance. 5. Choose a flow assembly with or without a panel mount. 6. Accessorize. Make your calibration high-tech. Check out the IntelliScan® handheld. Vision UV Single System Process Controller Catalog # Description UVPSI XXX Prewire, 115VAC, No Communications, No Panel UVP2SXXX Prewire, 115VAC, Modem Connection, No Panel UVP3SXXX Prewire, 115VAC, Ethernet Connection, No Panel Vision LV Dual System Process Controller LVPI SXXX Prewire, 115VAC, No Communications, No Panel LVP2SXXX Prewire, 115VAC, Modem Connection, No Panel LVP3SXXX Prewire, 115VAC, Ethernet Connection, No Panel Vision IntelliSense® Sensor Package ISPCSTDU015XXX Std. Conductivity Probe, USB Connection with 15' Cable ISPTSTDU015XXX Std. Toroidal Probe, USB Connection with 15' Cable ISPPSTDU015XXX Std. pH Probe, USB Connection with 15' Cable ISPOSTDU015XXX Std. ORP Probe, USB Connection with 15' Cable ISPMXXXU015XXX No Probe (for MPIO only), USB Connection with 15' Cable ISPCCBSU015XXX Boiler Conductivity Probe, USB Connection with 15' Cable Vision Flow Assembly FAOTXL No Sensor Tee, No Panel, Left Flow (Right Flow = XR) FA1TXL One Sensor Tee, No Panel, Left Flow FA2TXL Two Sensor Tees, No Panel, Left Flow FA3TXL Three Sensor Tees, No Panel, Left Flow Vision IntelliScan® Handheld Calibration Unit ISCNCDXXX IntelliScan® Unit Type - Conductivity ISCNPOXXX IntelliScan® Unit Type - ph/ORP ISCNCBXXX Combo (one conductivity sensor & one pH/ORP sensor) Model UV The Vision Series Model UV is a single system process control instrument. Included as standard are two IntelliSense® sensor connections allowing for the use of one Multipurpose IntelliSense® sensor input/output and one general sensor IntelliSense® sensor input (conductivity, torodial, pH or ORP); four selectable relays, one alarm relay, three taggable timers, one flow switch input, and one input suitable for use with dry contact or hall effect water meters. Model LV The Vision Series Model LV is a dual system process control instrument. As standard, it comes with three IntelliSense® sensor connections (allowing for the use of three general sensor inputs, two general sensor inputs and one multipurpose input/output, or one general sensor input and two multipurpose inputs/outputs), four selectable relays, one alarm relay, six taggable timers, two flow switch inputs, and two inputs suitable for use with dry contact or hall effect water meters. IntelliSense® Sensor Package By converting an analog input to a digital signal, the IntelliSense® sensor provides auto sensor recognition, eliminates drifting potential and allows travel up to 1000 feet (when using a RS-422 connection). USB connections are limited to 15 feet. Each of the 5 available sensory heads are color coded and measure a multitude of variables. NOTE: The multipurpose IntelliSense® sensor can only be used with a USB connection and consists of four functions (a contact input and output, and a 4-20mA input and output0, which can all be used simultaneously or independently. Flow Assembly The flow assembly features 3/4" PVC plumbing with a flow switch and sample valve. When ordering the flow assembly you can specify if you would like it mounted on a panel with the process control instrument. IntelliScan® Handheld Calibration Unit The IntelliScan® Unit is a handheld device that revolutionizes the calibration process by eliminating the need for manual data entry. It has an infrared port that allows calibration data to be transmitted to the IntelliSense® sense form the IntelliScan® unit. The IntelliScan® unit comes with its own convenient carrying case and belt-clip attachment. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents CHEMICAL FEED SYSTEMS AND ACCESSORIES - STORAGE AND BULK TANKS 79 Reverse Osmosis & Bleach Storage Tanks Siemens offers a wide variety of storage and bulk tanks for RO systems and bleach. Each RO tank is constructed of HDPE and bleach tanks are HDXLPE and is rated at 1.90 S.G. with OR1000 lining. All tanks are NSF Certified and fitting packages are available. Secondary containment is also offered as well as heat tracing and seismic restraints. ORDERING INFORMATION Reverse Osmosis Water Storage Tanks – HDPE Catalog # Nominal Capacity Approx. O.D. 1006150 1005050 1004150 1003000 1002000 1001150 1100475 1000100 10' – 2" 7' – 10" 8' – 6" 7' – 1" 7' – 1" 5' – 4" 4' – 0" 1' – 11" 6150 5050 4150 3000 2000 1150 475 100 Approx Overall Height Lid Size 12' – 4" 16' – 0" 12' – 6" 11' – 8" 8' – 6" 8' – 2" 6' – 3" 5' – 7" 24" 24" 24" 24" 24" 10"/19" 17" 7" Approx. Overall Height Lid Size Reverse Osmosis Water Storage Tanks – Fittings Catalog # Description Venting 7457 3" Mushroom Vent – PP Pump Suction 7117 2" BHF PVC/EPDM 4844 Nipple 2" x Short PVC 3188 2" T x T Spears Compact Ball Valve PVC Level 7117 2" BHF PVC/EPDM Fill 7117 2" BHF PVC/EPDM Optional Overflow 7117 2" BHF PVC/EPDM Bleach Storage & Bulk Tanks Catalog # Nominal Capacity Approx. O.D. 1000540 1000805 1000905 1001300 1001400 1002000 1002650 1003900 4' – 0" 4' – 0" 5' – 4" 7' – 1" 5' – 4" 7' – 1" 8' – 0" 7' – 10" 540 805 907 1300 1400 2000 2650 3900 6' – 9" 9' – 11" 6' – 9" 5' – 10" 10' – 0" 8' – 6" 8' – 9" 12' – 9" 19" 19" 19" 19" 19" 24" 24" 24" Secondary Containment Catalog # 1500700 1500960 1501200 1502000 1501750 1502650 1503350 1504500 Note: Larger tanks sizes are available. Contact Stranco® at 800-882-6466 for additional information. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 80 CLARIFIERS Chevron Tube Treated Water Settler Supports Collector Raw Water Inlet Overflow Treated Water Outlet Permutit® Package Precipitators Flow Rates from 44 to 920 gpm Package Precipitators offer an efficient means for removing impurities from a liquid by precipitation, adsorption, settling and upflow filtration. Used for the initial treatment of water to reduce suspended impurities, turbidity, color, hardness, iron and manganese, the Package Precipitator provides high rate clarification in minimum space. Adaptable to variable flow rates, it offers excellent chemical efficiency and produces low turbidity effluent. Optional Chevron shape, high rate tube settlers offer over 35% increased flow rate. Agitator Drains Sludge Blowoff • Low turbidity precipitator effluent is virtually always superior to the effluent of conventional clarifiers/softeners • The action of suspended sludge in the mixing zone and upflow through the sludge blanket utilizes chemicals more efficiently • Large, slow moving agitator blades completely mix the water, chemicals and sludge • The low turbidity effluent of a precipitator places little load on downstream filters, thus permitting longer filter runs and lower treatment costs SYSTEM SPECIFICATIONS Model Number Maximum Flow Rate Without Tube Settlers . . . . . . . . . . . . . . . . With Tube Settlers . . . . . . . . . . . . . . . . . . Surface Area . . . . . . . . . . . . . . . . . . . . . . . . Tube Settling Area . . . . . . . . . . . . . . . . . . . . Agitator Motor . . . . . . . . . . . . . . . . . . . . . . . Inlet/Outlet Overflow Size . . . . . . . . . . . . . . Sludge, Blow-off & Flush-back Valve Size . . . . . . . . . . . . . . . . . . . . . . . . . . Detention (60 minutes). . . . . . . . . . . . . . . . . 1 2 3 4 5 6 44 gpm 60 gpm 35 sq. ft. 25 sq. ft. 1/2 hp 3” 88 gpm 120 gpm 70 sq. ft. 50 sq. ft. 1/2 hp 4” 132 gpm 180 gpm 105 sq. ft. 75 sq. ft. 1/2 hp 6” 175 gpm 240 gpm 140 sq. ft. 100 sq. ft. 1/2 hp 6” 220 gpm 300 gpm 175 sq. ft. 125 sq. ft. 3/4 hp 8” 250 gpm 350 gpm 200 sq. ft. 150 sq. ft. 3/4 hp 8” 1” 2,600 gal. 1-1/2” 5,200 gal. 1-1/2” 7,800 gal. 2” 10,400 gal. 2” 13,000 gal. 2” 15,000 gal. 96x120x126 244x305x320 96x180x126 244x457x320 96x240x126 244x610x320 96x300x126 244x762x320 108x300x126 275x762x320 9,000 4,082 12,000 5,454 15,000 6,804 18,000 8,165 19,000 8,618 7 8 9 10 11 12 280 gpm 400 gpm 225 sq. ft. 175 sq. ft. 3/4 hp 8” 310 gpm 450 gpm 250 sq. ft. 200 sq. ft. 3/4 hp 8” 340 gpm 500 gpm 275 sq. ft. 225 sq. ft. 3/4 hp 10” 460 gpm 680 gpm 375 sq. ft. 300 sq. ft. 1 hp 10” 540 gpm 800 gpm 440 sq. ft. 350 sq. ft. 1 hp 12” 620 gpm 920 gpm 505 sq. ft. 400 sq. ft. 1-1/2 hp 12” 2” 16,800 gal. 2” 18,600 gal. 2” 20,500 gal 2” 27,700 gal. 2” 32,500 gal. 3” 37,350 gal. 132x300x126 335x762x320 144x300x126 366x762x320 144x408x126 366x1036x320 144x480x126 366x1219x320 144x552x126 366x1402x320 21,000 9,526 22,000 9,980 30,000 13,608 35,000 15,876 38,000 17,237 System Dimensions WxLxH inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96x60x126 cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244x153x320 Shipping Weight lb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,000 kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,722 Model Number Maximum Flow Rate Without Tube Settlers . . . . . . . . . . . . . . . . With Tube Settlers . . . . . . . . . . . . . . . . . . Surface Area . . . . . . . . . . . . . . . . . . . . . . . . Tube Settling Area . . . . . . . . . . . . . . . . . . . . Agitator Motor . . . . . . . . . . . . . . . . . . . . . . . Inlet/Outlet Overflow Size . . . . . . . . . . . . . . Sludge, Blow-off & Flush-back Valve Size . . . . . . . . . . . . . . . . . . . . . . . . . . Detention (60 minutes). . . . . . . . . . . . . . . . . System Dimensions WxLxH inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120x300x126 cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305x762x320 Shipping Weight lb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20,000 kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,072 ORDERING INFORMATION For Permutit ® products and information contact 908-704-9027. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 81 CLEAN-IN-PLACE SKIDS CIP Series Cleaning Skids Flow Rates from 30 to 225 gpm CIP Series Cleaning Skids are designed for on-site cleaning of RO systems. They can accommodate cleaning flow rates of 30–225 gpm and are compatible with TFC or CA membrane elements. • Factory assembled, tested and field-ready cleaning skids offer a convenient and economical way to maximize your RO investment • Rugged construction withstands cleaning chemicals • CIP-30, CIP-60 are portable for quick and easy on-site cleaning SYSTEM SPECIFICATIONS Model Number CIP-30 CIP-60 CIP-90 CIP-150 CIP-225 System Dimensions H x W x D* Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67x41x72 26x16x28 69x41x72 27x16x28 69x51x90 27x20x35 69x64x106 27x25x42 78x78x128 31x31x50 1250 567 2600 1179 3500 1588 6000 2722 9500 4309 Flow Rate at 60 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tank Capacity (gallons) . . . . . . . . . . . . . . . . . . . . . . . . . Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Weight Industrial lb. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Requirements Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ORDERING INFORMATION Catalog Number 67/CIP System Name . . . . . . . . . . . . . . 67/CIP XX(X) 30 gpm 90 1.5" Mobile 60 gpm 200 2" Mobile 90 gpm 275 2" Fixed 150 gpm 440 3" Fixed 225 gpm 800 3" Fixed 5 HP 5 HP 10 HP 10 HP 15 HP 240/480V/60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 = 30 gpm 60 = 60 gpm 90 = 90 gpm 150 = 150 gpm Flow Rates . . . . . . . . . . . . . . . . . . . . . . 225 = 225 gpm Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – XXX 240 = 240V, 60 Hz 480 = 480V, 60 Hz (Other voltages available. Contact technical support) Example: 67/CIP30-240 gpm system using 240 volts. Cleaning Skid Options (order as separate line item) Description pH Monitor High Temperature Switch Flow Switch 1" x 25' Hose Kit 1-1/2" x 25' Hose Kit 2" x 25' Hose Kit 3" x 25' Hose Kit Part Number 24/S1900-170 24/S1900-171 24/S1900-172 24/S1900-181 24/S1900-182 24/S1900-183 24/S1900-184 In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 82 CONTINUOUS DEIONIZATION (CDI®) SYSTEMS CDI-LX™ Systems Flow Rates from 2.5 to –180 gpm Continuous electrodeionization is a safe, chemical-free way to take RO (reverse osmosis) water to a higher level of purity. CDI-LX™ systems are pre-engineered and specifically designed to meet the demands of the pharmaceutical, power, microelectronics and general industry customer. The standard CDI-LX™ systems have flow rates from 2.5 to 180 gpm (0.57–40.88 m3/hr), combining single or multiple (up to 8) CDI-LX™ modules on a frame with power supply, controllers, piping, sample valves and cleaning connections. Flow and quality monitoring instrumentation is standard. Remote I/O is also available as an option. Features: • Rugged construction • Easily validated • Hot water sanitizable (HWS) units • Leak-free operation available up to 185˚F (85˚C) • High operating pressure (up to 100 psi) • High operating temperature • Low power consumption (up to 45˚C; 113˚F) SYSTEM SPECIFICATIONS Model Number CDILXH Number of Modules on Skid 1001 1 2401 1 3001 1 3002 2 3003 3 3004 4 3006 6 3008 8 Minimum Flow Rate gpm (m3/hr) Nominal Flow Rate gpm (m3/hr) Maximum Flow Rate gpm (m3/hr) 2.5 (.57) 5 (1.13) 7.5 (1.70) 6.25 (1.42) 12.5 (2.84) 18.75 (4.26) Connections Feed Product Reject 90-95% 90-95% 90-95% 90-95% 90-95% 90-95% 90-95% 3/4” 3/4” 1/2” 1” 1” 1/2” 1” 1” 1/2” 1-1/2” 1-1/2” 1/2” 2” 2” 1” 2” 2” 1” 3" 3" 1-1/2” 3" 3" 1-1/2” 60 80 130x40x78 330x102x198 5000 (2268) 130x40x78 330x102x198 5600 (2540) Typical recovery Electrical Service Required Voltage Amperage Catalog Number: System Name CDILX CDILX 208/240V, 1 phase, 50/60 Hz 40 40 15 System Dimensions L x D x H inches cm Shipping Weight lb. (kg) (est.) ORDERING INFORMATION 90-95% 7.5 (1.70) 15 (3.41) 22.5 (5.11) 40x33x77 102x83x196 500 (227) X 40x33x77 102x83x196 530 (240) XX 40x33x77 102x83x196 550 (250) XX X 15 (3.41) 30 (6.81) 45 (10.22) 20 40x33x77 102x83x196 900 (408) 22.5 (5.11) 45 (10.22) 67.5 (15.33) 30 (6.81) 60 (13.63) 90 (20.44) 480V, 3 phase, 50/60 Hz 30 40 75x40x83 191x102x211 3000 (1361) 75x40x83 191x102x211 3300 (1497) X X H = Hot Water Sanitizable (HWS) Module X = Non-HWS Module 01 02 10 03 1 = 240V, 24 04 A = PVC, Sch. 80 1 Phase, 50/60 Hz 06 Number of Cell Pairs/Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 (Non HWS Model only) 2 = 208V, Number of Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08 D = 316L SS, Sanitary Tube (for 1 Phase, 50/60 Hz Feed and Product Plumbing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HWS Model and X Models) 4 = 480V, Electrical Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Phase, 50/60 Hz *Not all model combinations are available. Contact Siemens for specific CDI-LX™ applications beyond the standard specifications. To determine your order number, replace the X with one of the numbered options below it. “X” must be specified if option is not requested. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 45 (10.22) 90 (20.44) 135 (30.66) A = NEMA 12 without Remote I/O B = NEMA 12 with Remote I/O C = NEMA 4 without Remote I/O D = NEMA 4 with Remote I/O E = NEMA 4X without Remote I/O F = NEMA 4X with Remote I/O In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Section Table of Contents 60 (13.63) 120 (27.25) 180 (40.88) 83 CONTINUOUS ELECTRODEIONIZATIONSYSTEMS CDI® Replacement Modules CDI® Replacement modules are available for both older legacy CDI® Systems and current standard CDI® Systems. Available legacy CDI® modules: H-Series (H30, H60, H120, H240), P-Series (P-180) and Compact CDI® (C10, C20, C40) Systems. Unfortunately, the above H-Series and Compact CDI® modules cannot be replaced by LX or VNX modules due to incompatibilities with the power supply. CDI® P-180 System Upgrade: Because of the cost savings and benefits associated with the CDI® LX Series, many existing P-180 customers are now upgrading to the LX Series, and a complete upgrade kit is available. The kit is specifically designed to replace the P-180 modules with minimal field retrofit labor required. The upgrade kit includes simplified connections to match the existing P-180 system connections. LX and VNX Modules: Replacement CDI® modules for current standard LX and VNX systems. Benefits of LX and VNX include: • Offers the latest generation of continuous electrodeionization technology • Offers a robust design for superior performance with the highest reliability in the industry • Guarantees leak-free operation • Uses the existing skid/footprint, power supplies, instruments and controls H Series Model Numbers H30 H60 H120 H240 P-Series Model Numbers For All Models LX Series Model Numbers 4 cell pair module – non-hot water sanitizable 10 cell pair module – non-hot water sanitizable 18 cell pair module – non-hot water sanitizable 24 cell pair module – non-hot water sanitizable 30 cell pair module – non-hot water sanitizable 4 cell pair module – instant hot water sanitizable 10 cell pair module – instant hot water sanitizable 18 cell pair module – instant hot water sanitizable 24 cell pair module – instant hot water sanitizable 30 cell pair module – instant hot water sanitizable 24 cell pair module – E-Cell® replacement 30 cell pair module – E-Cell® replacement P-180 Upgrade Kit VNX Series Model Number VNX-X3 VNX50 Replacement Module Catalog Number ZM3H030CP ZM3H060CP ZM3H120CP ZM3H240CP CDIPM0180C IP-LXM04X-3 IP-LXM10X-3 IP-LXM18X-3 IP-LXM24X-3 IP-LXM30X-3 IP-LXM4HI-3 IP-LXM10HI-3 IP-LXM18HI-3 IP-LXM24HI-3 IP-LXM30HI-3 IP-LXM24MK-1 IP-LXM30MK-1 IP-LXMP180 IP-VNX-X3 IP-VNX50 NOTE: 1) The Compact Series replacement modules are also available; Contact Siemens for additional details. 2) Please locate the module serial number located on the anode junction box for correct replacement. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 84 CONTROL PANELS H2O Control The H2O Control panel family is a product offering of control panels that include pump starter panels (single phase up to 2 HP and three phase up to 10 HP) as well as alarm* and remote alarm* panels. Continuously on lamps are robust LED’s, alarm lamps are bright visible incandescent bulbs. All panels are UL and cUL Listed. Panels not specifically listed as part of the product line are also available as custom panels. • All panels offered as NEMA 4/12, NEMA 4X Composite, NEMA 4X Stainless steel • Single phase pump starter panels offered as 120 or 220 VAC with options for Simplex, Duplex, and Duplex with alternating timer • Three phase pump starter panels offered as 208, 230, 460, or 575 VAC with options for Simplex, Duplex, Duplex with alternating timer, auxiliary interclock, alarm • All wires and screw terminals labeled for easy identification • Panel drawing provided with each panel 1-Phase Pump Starter 3-Phase Pump Starter Alarm* Remote Alarm* * Alarm and Remote Alarm panels have not been approved for use in dialysis applications. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 85 DEAERATORS Permutit® SLH Deaerating Heaters Flow Rates from 18 to 300 gpm Permutit® SLH Deaerating Heaters remove oxygen, free carbon dioxide and other non-condensable gases from make-up water used for boiler feed, as well as from return condensate. This product combines simplicity and compactness with high performance and operational efficiency. SLH horizontal deaerating heaters are ideal for low-pressure boiler plants. • Compact construction keeps headroom and space requirements to a minimum • Violent scrubbing action assures complete heating and deaeration • Maximum efficiency is achieved by preheating water to near steam temperature • Unique stainless steel internal direct contact vent condenser makes the required vent rate so low it almost eliminates steam loss • Simple, inexpensive installation • Furnished with internal vent condenser and spray valves, inlet control valve, overflow control, thermometer, sentinel relief valve, pressure gauge, gauge glasses and structural support SYSTEM SPECIFICATIONS Model Number Outlet Capacity lb./hour . . . . . . . . . . . . . . . . . . . . . . . . gpm. . . . . . . . . . . . . . . . . . . . . . . . . . . Storage lb. . . . . . . . . . . . . . . . . . . . . . . . . . . . . gallons . . . . . . . . . . . . . . . . . . . . . . . . System Dimensions HxDxW feet . . . . . . . . . . . . . . . . . . . . . . . . . m........................... Shipping Weight lb.. . . . . . . . . . . . . . . . . . . . . . . . . . . kg. . . . . . . . . . . . . . . . . . . . . . . . . . . SLH-9 SLH-18 SLH-30 SLH-50 SLH-70 SLH-90 SLH-110 SLH-150 9,000 18 18,000 36 30,000 60 50,000 100 70,000 140 90,000 180 110,000 220 150,000 300 1,500 180 3,000 360 5,000 600 8,333 1,000 11,667 1,400 15,000 1,800 18,333 2,200 25,000 3,000 7x8x10 17x20x25 7x8x13 17x20x33 7x8x17 17x20x43 8x9x18 20x23x46 9x10x17 23x25x43 9x10x20 23x25x50 9x10x28 23x25x71 9x10x27 23x25x68 1,920 871 2,360 1,070 3,010 1,365 4,200 1,905 5,160 2,340 5,860 2,658 6,900 3,130 8,000 3,628 Vessels are designed per the ASME Code. Minimum shell and head-plate thickness 1/4". Units with <50,000 lb. capacity are 50 psi ASME Code design pressure. Units with >50,000 lb. capacity are 30 psi ASME Code design pressure. ORDERING INFORMATION For Permutit® products and information, contact 908-704-9027. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 86 DEGASIFIERS DG Series Forced Draft Decarbonators Flow Rates from 15 to 400 gpm DG Series Forced Draft Decarbonators are designed to remove dissolved gases from process water without changing its ambient temperature. The DG Series reduces the load on deionization equipment and can extend the usable life of neutralization chemicals and eliminates gas-related problems from the process stream. The DG Series may also be used to oxidize dissolved iron and manganese for removal by filtration or clarification. • Large clearwell (storage tank) eliminates the need for additional storage facilities • Polypropylene hollow sphere packing provides a high active surface area for air contact with water for rapid and efficient gas removal • Easy to maintain with removable top for access inside and a packing section clean-out • Fiberglass tower with a flat sealed bottom and top air inlet distributor evenly distribute incoming water over the surface of the packing • Skid mounted stainless steel transfer pumps are available • Optional HEPA filters remove airborne particles as small as 0.5 micron SYSTEM SPECIFICATIONS Model Number Flow rate . . . . . . . . . . . . . . . . . . . . . . . . . Air at 1' WC (Water Column). . . . . . . . . . Clearwell Capacity. . . . . . . . . . . . . . . . . . Packing Volume (cubic ft.). . . . . . . . . . . . System Dimensions Tower Diameter . . . . . . . . . . . . . . . . . . . . Clearwell Diameter . . . . . . . . . . . . . . . . . Height . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Weight lb. . . . . . . . . . . . . . . . . . . . . . . . . . . . . kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . . . . . DG-12 15 gpm 350 cfm 190 gal 6 DG-18 35 gpm 350 cfm 259 gal 15 DG-24 DG-30 DG-36 DG-42 DG-48 DG-54 DG-60 12" 3' 13' 18" 3.5' 14'-6" 24" 4' 15' 30" 4.5' 16' 36" 5' 16' 42" 6' 16' 48" 6' 17' 54" 8' 16' 60" 8' 17' Number DG-12 DG-18 DG-24 DG-30 DG-36 DG-42 DG-48 DG-54 DG-60 Decarbonators Catalog Number 100 gpm 490 cfm 549 gal 40 150 gpm 775 cfm 677 gal 55 200 gpm 1100 cfm 976 gal 80 250 gpm 1375 cfm 1189 gal 105 300 gpm 1575 cfm 1735 gal 130 400 gpm 2100 cfm 2115 gal 165 2,100 2,700 3,400 5,300 6,200 8,900 10,900 15,900 19,400 953 1,225 1,542 2,404 2,812 4,037 4,944 7,212 8,800 480V/3 phase/60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ORDERING INFORMATION Model 60 gpm 350 cfm 339 gal 25 Catalog Number 67/S2201-120 67/S2201-180 67/S2201-240 67/S2201-300 67/S2201-360 67/S2201-420 67/S2201-480 67/S2201-540 67/S2201-600 24/S2201-710 24/S2201-710 24/S2201-710 24/S2201-720 24/S2201-730 24/S2201-740 24/S2201-750 24/S2201-760 24/S2201-770 Optional HEPA Filter Kit Description HEPA Filter Kit, 120, 180, 240 HEPA Filter Kit, 120, 180, 240 HEPA Filter Kit, 120, 180, 240 HEPA Filter Kit, 300 HEPA Filter Kit, 360 HEPA Filter Kit, 420 HEPA Filter Kit, 480 HEPA Filter Kit, 540 HEPA Filter Kit, 600 In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 87 DEIONIZERS Deionization Recirculating Systems (DIRS) Flow Rates from 5 to 50 gpm Economical, pre-packaged water purification systems producing high purity water. Depending on water quality requirements, systems are designed to permit several different field configurations to accommodate specific requirements. For ease and flexibility of operation, the systems are controlled by a PLC integral to the skid. Systems with higher flow rates and/or alternate plumbing options are available with little or no impact to delivery times. • Small skid mounted footprint to conserve valuable floor space • Schedule 80 PVC piping with optional pigmented polypropylene (PP) for post-treatment piping • Powder-coated steel frames for maximum support of DIRS system while allowing easy access for maintenance and operation • Fully assembled system that is wired and hydrostatically tested prior to shipment • Complete documentation package including installation, start-up and operation procedures, P&ID, Electrical Schematics and Quality Assurance data reports • PLC controls allow for multiple field configurations without altering the control system hardware • Fast delivery with pre-manufactured systems • Quick installation and startup with typically less than one day need for system operation • Minor field changes permit installation in one of the three configurations shown below • UL and Seismic Zone 4 compliance to meet regional permitting regulations Configuration #1 Configuration #2 Configuration #3 In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 88 DEIONIZERS VP Series Two Bed Deionizers Flow Rates from 10 to 220 gpm VP Series Two Bed Deionizers are designed and manufactured for industrial applications. They are rugged, pre-engineered, pre-assembled, standardized units that minimize expensive installation and start-up costs. VP Series Two Bed Deionizers consist of an acid regenerated cation vessel piped in series with a caustic regenerated anion vessel. These pre-engineered units provide high-quality water over the length of the service cycle. Operating conditions and an influent water analysis are required for predicting effluent quality and total volume of water treated before regeneration is required. To reduce field fit-up problems with interconnecting piping, the VP Series Two Beds must be ordered with the skid-mounted option. • Simple design maximizes reliability, efficiency and repeatability • 100 psig vessel ratings offer added strength and integrity • Baked PVC lining and paint extend vessel life • PLC controls ensure extremely reliable operation • Inlet flow meter assures consistent performance • Conductivity monitor assures consistent water quality • Schedule 80 PVC piping ensures long life and does not degrade water quality SYSTEM SPECIFICATIONS Diameter 016 Service Flow Rate (gpm) . Minimum Flow Rate (gpm) Media (cubic feet) Cation Resin Volume (ft3) Capacity (kgr) . . . . . . . . Anion Resin Volume (ft3) . . . Capacity (kgr) . . . . . . . . Pipe Size . . . . . . . . . . . . . . System Dimensions H x L x W . . . . . . . . . .inch . . . . . . . . . . . . . .cm Shipping Weight lb (kg) . . . . . . . . . . . . . . . 020 024 030 036 042 048 054 060 066 072 10 3 17 4 24 6 38 10 54 14 74 19 97 23 123 31 153 39 182 47 220 55 4 80 6 120 10 200 15 300 21 420 28 560 36 720 46 920 57 1,140 69 1,380 82 1,640 4.5 77 1” 7 120 1” 11 190 1” 17 290 1-1/4” 24 410 1-1/2” 33 560 2” 42 715 2” 54 920 2-1/2” 67 1,140 3” 81 1,380 3” 96 1,640 4” 96x56x43 97x64x48 99x72x50 108x84x59 114x96x62 118x108x65 120x120x78 125x132x82 127x144x84 132x156x92 136x168x100 244x142x117 246x162x122 251x183x127 274x213x150 289x244x157 300x274x165 305x305x198 317x335x208 322x366x213 335x396x234 345x427x254 1800 (817) 2900 (1316) 3800 (1724) 4400 (1996) 6000 (2722) 7860 (3566) 9670 (4387) 11880 (5389) 14880 (6750) 20040 (9090) 25200 (11431) Electrical Requirements . 120 V/60 Hz/single phase/15 amps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number: VPT ORDERING INFORMATION S System..................................... VPT Configuration............................................... S=Simplex* XXX X X B P 016 - 16"x72" 048 - 48"x72" 020 - 20"x72" 054 - 54"x72" 024 - 24"x72" 060 - 60"x72" 030 - 30"x72" 066 - 66"x72" A=100 psig 036 - 36"x72" 072 - 72"x72" ASME code Y=Skid, seismic Vessel Size ............................................................................... 042 - 42"x72" X=100 psig zone 2A Vessel Rating .............................................................................................................................................. non-code Z=Skid, seismic Vessel Support ......................................................................................................................................................................... zone 4 B=PVC lining Lining and Paint......................................................................................................................................................................................................... and paint P=SolidControls ................................................................................................................................................................................................................................................. State PLC Control Rating ............................................................................................................................................................................................................................................................... *Duplex units should be ordered as two (2) simplex units. To determine your order number, replace the X with one of the numbered options below it. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents D D=NEMA 4/UL 89 DEIONIZERS VP Series Mixed Bed Deionizers Model VPM Flow Rates from 16 to 330 gpm VP Series Mixed Bed Deionizers are designed and manufactured for industrial applications. They are rugged, pre-engineered, pre-assembled, standardized units that minimize expensive installation and start-up costs. Their simple design maximizes the efficiency and repeatability of the unit during the service and regeneration modes in order to provide a truly reliable water treatment unit. VP Series Mixed Bed Deionizers consist of a single vessel that contains both cation and anion ion exchange resins. The cation resin is a strong acid type. The anion resin is a strong base, Type II. These pre-engineered units provide high-quality water over the length of the service cycle. Operating conditions and an influent water analysis are required for predicting the effluent quality and total volume of water treated before regeneration is required. • Simple design maximizes reliability, efficiency and repeatability • 100 psig vessel ratings offer added strength and integrity • Baked PVC lining and paint extend vessel life • PLC controls ensure extremely reliable operation • Inlet flow meter assures consistent performance • Resistivity monitor assures consistent water quality • Schedule 80 PVC piping ensures long life and does not degrade water quality SYSTEM SPECIFICATIONS Diameter 016 Service Flow Rate (gpm) . . . . . Minimum Flow Rate (gpm) . . . . Media (cubic feet) Cation Resin Volume (ft3) . . . . Capacity (kgr) . . . . . . . . . . . . Anion Resin Volume (ft3) . . . . . Capacity (kgr) . . . . . . . . . . . . Pipe Size . . . . . . . . . . . . . . . . . . System Dimensions H x L x W . . . . . . . . . . . . . .inch . . . . . . . . . . . . . . . . . . . . . . .cm Shipping Weight lb (kg) . . . . . . . . . . . . . . . . . . . . Electrical Requirements . . . . ORDERING INFORMATION Catalog Number: 16 3 25 4 020 36 6 024 56 10 030 82 14 036 112 19 042 145 23 048 054 185 31 229 39 060 272 47 066 330 55 072 1.5 30 2.5 25 1" 2 40 4 40 1" 3 60 6 60 1-1/4" 6 120 13 130 1-1/2" 9 180 18 180 2" 12 240 25 250 2-1/2" 16 320 32 320 3" 21 420 41 410 3" 25 500 51 510 4" 31 620 62 620 4" 37 740 73 730 4" 89x48x52 89x51x55 117x54x56 226x122x132 226x129x140 297x137x142 132x57x60 141x63x66 145x70x70 200x78x75 335x145x152 358x160x173 368x178x178 508x198x191 159x90x78 159x96x84 166x106x93 174x117x112 404x229x198 404x244x213 422x269x236 442x297x259 1080 (490) 3000 (1361) 6170 (2799) 1750 (794) 2280 (1034) 3700 (1678) 4530 (2055) 5330 (2418) 7570 (3434) 10080 (4572) 12470 (5657) 120V/60 Hz/single phase/15 amps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VPM S System . . . . . . . . . . . . . . . . VPM Configuration. . . . . . . . . . . . . . . . . . . . . . . . S=Simplex* XXX X X B P D 016 - 16"x72" 048 - 48"x96" 020 - 20"x72" 054 - 54"x96" 024 - 24"x72" 060 - 60"x96" X=Legs, seismic 030 - 30"x96" 066 - 66"x96" A=100 psig zone 4 036 - 36"x96" 072 - 72"x96" ASME code Y=Skid, seismic Vessel Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 042 - 42"x96" X=100 psig zone 2A Vessel Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . non-code Z=Skid, seismic Vessel Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . zone 4 B= Baked Lining and Paint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PVC P=SolidControls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . State PLC D=NEMA 4 Control Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . and UL Label *Duplex units should be ordered as two (2) simplex units. To determine your order number, replace the X with one of the numbered options below it. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 90 DEIONIZERS VP Series Deionizer Accessories Model VPZ VP Series Deionizer accessories provide additional flexibility for mixed bed and two bed deionizers. These accessories are pre-engineered, pre-assembled catalog units that are shipped loose for field installation on the deionizer. Low Flow Recirculation (LFR): The low flow recirculation accessory ensures high water quality from the deionizer when operating at flow rates below the minimum specified rate. The recirculation pump automatically runs when the service flow rate drops below the minimum specified rate. The recirculation pump is a 316 stainless steel, close-coupled, centrifugal pump with a 115 volt, TEFC motor. Also included is a local control enclosure that is wired directly to the main control enclosure on the deionizer. Diameter Recirculation Flow Rate (gpm) Horse Power . . . . . . . . . . . Size Code . . . . . . . . . . . . . . 016 3 0.5 016 020 4 0.5 020 024 030 6 0.5 024 10 0.5 030 036 14 0.5 036 042 19 0.75 042 048 23 0.75 048 054 31 0.75 054 060 39 1.0 060 066 47 1.0 066 072 55 1.0 072 Effluent Resin Trap (TRP): The effluent resin trap accessory prevents the loss of ion exchange resin from the deionizer vessel in the unlikely event of underdrain failure. The effluent resin trap consists of a clear section of PVC pipe with a PVC slotted strainer. The effluent resin trap is installed in the service effluent piping of the anion or mixed bed vessel. Diameter Mixed Bed Pipe Size . . . . . Mixed Bed Size Code . . . . Two Bed Pipe Size . . . . . . . Two Bed Size Code . . . . . 016 1" 100 1" 100 020 1" 100 1" 100 024 030 1-1/4" 125 1" 100 1-1/2" 150 1-1/4" 125 036 2" 200 1-1/2" 150 042 2-1/2" 250 2" 200 048 3" 300 2" 200 054 3" 300 2-1/2" 250 060 4" 400 3" 300 066 4" 400 3" 300 072 4" 400 4" 400 Pressure Reducing Regulator (PRV): The pressure reducing regulator accessory ensures consistent and reliable operation of the deionizer when the feedwater undergoes fluctuations in pressure. This self-contained regulator is installed on the feedwater inlet of the deionizer. Diameter Mixed Bed Pipe Size . . . . . Regulator Size . . . . . . . . . . Mixed Bed Size Code . . . . Two Bed Pipe Size . . . . . . . Regulator Size . . . . . . . . . . Two Bed Size Code . . . . . 016 1" 3/4" 075S 1" 3/4" 075S 020 1" 3/4" 075D 1" 3/4" 075D 024 1-1/4" 1" 100D 1" 1" 100D ORDERING INFORMATION Order as separate items Catalog Number: VP Z Reserved . . . . . . . . . . . . . . . . . . . . . . . . . . Accessory 030 Size Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............ 1-1/2" 1-1/4" 125S 1-1/4" 1-1/4" 125S XXX See tables for size code ................ ................ Accessory Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 036 2" 1-1/4" 125D 1-1/2" 1-1/4" 125D 042 2-1/2" 2" 200S 2" 2" 200S 048 3" 2" 200D 2" 2" 200D 054 3" 2" 200D 2-1/2" 2" 200D 060 4" 2-1/2" 250S 3" 2-1/2" 250S 066 4" 2-1/2" 250D 3" 2-1/2" 250D XXX LFR-Low flow recirculation pump TRP-Resin trap PRV-Pressure reducing regulator In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 072 4" 3" 300S 4" 3" 300S 91 DIALYSIS (HEMODIALYSIS) Hemodialysis Bicarbonate Mixing and Dispensing System This Siemens Water Technologies system provides consistent bicarbonate mixing and dispensing. This semi-automatic system reduces the technician’s time and efforts by automating all operations, especially cleaning. It delivers solution directly to the distribution loop. Features that make the difference include: • Plastic components provide superior corrosion resistance • Simple, yet rugged construction ensures high reliability • Pre-assembled, skid-mounted systems reduce installation time and cost • Programmable Logic Control system meets exacting automatic operational requirements • 50 and 100 gallon tank models are available Model Number BICARB50 BICARB100 ORDERING INFORMATION Tank Capacity 50 GAL 100 GAL 50 GAL TANK. . . . . . . . . . . . BICARB50SYS Feed Loop Distribution 4 GPM@ 40psi Loop Return Feedwater Inlet 3/4" NPT Loop Return 3/4" NPT Drain 1" Socket Utility Requirements Waste Drain (min) 115 VAC, 1 Phase, 60Hz, 15A RO or DI water produced to AAMI standards for Hemodialysis 1" Physical Dimensions Specifications* Length 70" 83" 60" 60" Depth 27" Shipping Weight 300 lbs Height Operating Weight 100 GAL TANK. . . . . . . . . . . BICARB100SYS 1/2" NPT Loop Distribution Feedwater Part Number Optional Components Part Number Pressure Control Valve for Distribution Outlet. . . . . . . . . 05/ZIVC00141 4 GPM Skid Process Connection Specifications Electrical Service 2 GPM@ 30psi Catalog Item 35" 1800 lbs 350 lbs 2500 lbs *Does not include operating space requirements. For easy and safe operation, there should be a minimum of 2ft on each side and 4ft in front of the system. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 92 DIALYSIS (HEMODIALYSIS) Med-RO® Reverse Osmosis Medical Systems RX Series For Dialysis Applications Requiring From 1.5 to 15 gpm Med-RO® Reverse Osmosis medical systems are specifically designed for hemodialysis water treatment applications. Our Med-RO® RX Series offers you the greatest flexibility possible from a standard system. The control system is an easy-to-use advanced microprocessor based system. The Med-RO® RX series product flow ranges from 1.4 to 15 gpm. Features that make the difference include: • Manufactured for hemodialysis water treatment applications, FDA registration • Easier to clean – “full fit” thin film composite RO membranes mean less bacterial contamination and less biofilm buildup • Easy-to-use programmable controls for convenience • Small footprint requires minimal space • Reject recycle maximizes water recovery and minimizes waste • Clean-in-place connections minimize disinfection downtime and overall cleaning time • Systems manufactured at a QSR/ISO 9001 compliant registered facility • Used with Siemens registered medical pretreatment components • Registered with Health Canada as a medical device General Specifications RO Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conductivity Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Indicator (Product) . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Indicator (Reject) . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Indicator (Recycle) . . . . . . . . . . . . . . . . . . . . . . . . . . . Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless steel Epoxy coated 3/4” MNPT Rotameter, PVC/acrylic construction, 3/4” FPT connections Rotameter, PVC/acrylic construction, 3/4” FPT connections Rotameter, PVC/acrylic construction, 3/4” FPT connections Microprocessor, NEMA 4X enclosure Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 93 DIALYSIS (HEMODIALYSIS) SYSTEM SPECIFICATIONS Model Number RX01 Product Flow* (gpm) . . . . . . Feed Flow (gpm) . . . . . . . . . Reject Flow (gpm) . . . . . . . . Reject Recycle (gpm). . . . . . Connection Feed Inlet . . . . . . . . . . . . . . . Product Outlet . . . . . . . . . . . Reject to Drain Outlet . . . . . Waste Drain–max gpm. . . . . Floor Drain . . . . . . . . . . . . . . Membranes Membrane/Vessel . . . . . . . . Membrane Quantity . . . . . . . Membrane Type . . . . . . . . . . RO Vessels Vessel Array . . . . . . . . . . . . . Electrical Motor (hp). . . . . . . System Dimensions** HxWxD inches . . . . . . . . . . . . . . cm. . . . . . . . . . . . . . . . . Shipping Weight lb (kg) . . . . . . . . . . . . . . RX02 RX06 RX08 RX09 RX12 1-1⁄2” flange 1-1⁄2” flange 1-1/2” flange 1-1/2”” flange 1-1/2” flange 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 2.8 5.6 8.0 6.9 8.3 A floor drain (in addition to a waste drain) should be supplied for general maintenance 1-1/2” flange 3/4” NPT 3/4” NPT 9.3 1-1/2” flange 3/4” NPT 3/4” NPT 13.3 1-1/2” flange 3/4” NPT 3/4” NPT 16.0 1-1/2” flange 3/4” NPT 3/4” NPT 20.0 1 1 RO-4040-FF 1 2 RO-4040-FF 1 3 RO-4040-FF 1 4 RO-4040-FF 1 5 RO-4040-FF 1 6 RO-4040-FF 1 8 RO-4040-FF 1 9 RO-4040-FF 1 12 RO-4040-FF 1 5 1:1 5 1:1:1 5 1:1:1:1 5 1:1:1:1:1 5 1:1:1:1:1:1 5 2:2:1:1:1:1 10 3:2:2:1:1 10 3:3:2:2:1:1 10 76x34x42 193x86x107 76x34x42 193x86x107 76x34x42 193x86x107 76x34x42 193x86x107 76x34x42 193x86x107 76x34x42 193x86x107 76x34x42 193x86x107 76x34x42 193x86x107 76x34x42 193x86x107 475 (215) 500 (226) 540 (244) 550 (249) 590 (267) 630 (285) 750 (340) 800 (362) 825 (362) 1.4 2.8 1.4 7.0 RX03 2.8 5.6 2.8 5.0 RX04 4.0 8.0 4.0 4.0 5.2 6.9 1.7 6.0 RX05 6.2 8.3 2.1 6.0 7.0 9.3 2.3 6.0 10.0 13.3 3.3 8.0 12.0 16.0 4.0 11.0 15.0 20.0 5.0 10.0 *Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters. **Does not include servicing space requirements. STANDARD PRODUCT ORDERING INFORMATION Med-RO® Part Number Matrix / Single Pass Reverse Osmosis Units RX 01 Med-RO® MODEL 1 VESSEL 4 VESSELS 06 6 VESSELS 09 12 3 VESSELS 5 VESSELS 8 VESSELS 9 VESSELS 12 VESSELS RX OPTION DESIGNATIONS AX 208VAC 3PH 60HZ CX 460VAC 3PH 60HZ BX DX EX AX RO VESSEL QUANTITY DESIGNATION 04 08 04 centrifugal pump 2 VESSELS 05 RX Vertical w/ controller, medical RO, 02 03 MRO 230VAC 3PH 60HZ 380VAC 3PH 50HZ 575VAC 3PH 60HZ In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 94 GAUGES Pressure Gauges Liquid pressure gauges are designed to resist pulsation, shock, vibration, weather and most corrosive atmospheres. They are ideally suited for a broad range of plant, hydraulic and fluid power applications. • Offered with a 2.5" dial face, stainless steel exterior, and liquid filled (glycerine) with a 1/4" NPT stem mount • Available with brass or stainless steel internals (gauges used on DI or softened water must have stainless steel internals) • Sanitary gauges are 316 stainless steel, glycerine filled and include a 1.5" tri-clamp connection ORDERING INFORMATION Catalog No. PGBR03025 PGBR06025 PGBR10025 PGBR16025 PGSS03025 PGSS06025 PGSS10025 PGSS16025 Description Brass internals; range 0-30 psi Brass internals; range 0-60 psi Brass internals; range 0-100 psi Brass internals; range 0-160 psi Stainless steel internals; range 0-30 psi Stainless steel internals; range 0-60 psi Stainless steel internals; range 0-100 psi Stainless steel internals; range 0-160 psi Catalog No. PGSS40025 PG3A06035 PG3A10035 PG3A16035 PG3A06045 PG3A10045 PG3A16045 Description Stainless steel internals; range 0-400 psi 3.5" face; sanitary; 0-60 psi 3.5" face; sanitary; 0-100 psi 3.5" face; sanitary; 0-160 psi 4.5" face; sanitary; 0-60 psi 4.5" face; sanitary; 0-100 psi 4.5" face; sanitary; 0-160 psi Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 95 GAUGES Temperature Gauges Siemens offers a simple, bimetal temperature gauge designed to measure temperature in most non-sanitary applications. This gauge is constructed of 304 stainless steel, has a 3" dial face, a 4" long stem, with a 1/2"-14 NPT stem mount. ORDERING INFORMATION Catalog No. TGNS20030 Description Non-sanitary; range 0-200°F Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 96 HIGH PURITY WATER SYSTEMS PureFit™ High Purity Water Treatment Systems Flow Rates makeup from 2-20 gpm, recirculating up to 72 gpm The PureFit™ line of packaged systems is designed to address most common types of applications for high purity water with effluent resistivity of 16 megohm-cm or higher. PureFit™ systems include pretreatment, deionization, distribution and polishing, as packaged systems and are offered in a variety of configurations. Each system is completely pre-assembled at the factory, with only a few subassemblies that must be reconnected in the field. The only additional items required are service DI (and for HPX, carbon) bottles, that are supplied by the Branch. Equipment can be shipped in within 7-8 weeks after receipt of order, and field assembly and startup can often be accomplished in as little as 1-2 weeks. HPW: systems with make-up flow rates up to 8 gpm feature vertical RO pressure vessels with one element per housing; systems with make-up flow rates 12 gpm or higher feature horizontal RO arrays with three RO elements per housing. An antiscalant feed system is available in lieu of softeners on all HPW systems. Equipment layout is extremely compact. HPC: systems feature many of the same components used in the HPW systems but also include a softened water break tank and continuous electrodeionization instead of make-up service deionization. The CDI platform also includes a UV sterilizer to minimize any biological buildup in the recirculating make-up stream during periods of low DI water demand. HPX: systems feature service deionization instead of RO as the primary means of TDS reduction. As the SDI units can handle a wide range of flow rates a DI water storage tank is generally not required and the system footprint can be greatly reduced. Prefilters and distribution components are combined on one platform that sits adjacent to SDI and carbon bottles. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 97 HIGH PURITY WATER SYSTEMS PureFit™ High Purity Water Treatment Systems Flow Rates makeup from 2-20 gpm, recirculating up to 72 gpm • Powder-coated steel frames • PLC based control system • Full factory pre-assembly including piping, wiring, valves, hoses, cartridge filters, and other material items necessary for initial startup in the field • PVC pretreatment, socket-fusion polyproylene (PP) downstream of the DI storage tank on HPW and HPC systems, PVC post-treatment on HPX systems • Documentation: Operations & Maintenance Manual, System drawings including Process & Instrumentation Diagram and Electrical Schematics • Fast delivery and installation with pre-manufactured systems • UL and Seismic Zone 4 compliance to meet regional permitting regulations Contact a Siemens representative for detailed specifications. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 98 ION EXCHANGE RESINS AND FILTER MEDIA USF™ Ion Exchange Resin The selection, application and supply of ion exchange resins are critical to the performance and cost effectiveness of your water treatment system. For over 80 years, we have pioneered the development and application of a better ion exchange resin. Siemens USF™ resin is produced by the leading manufacturers to meet our stringent, performance based specifications. These standards are higher than those currently used by the manufacturers in testing their own products. With the purchase of USF™ resin, you are assured of the highest quality product at a competitive price. Advantages of Choosing USF™ resin: • Superior quality – resins are tested to meet stringent performance specifications • Strict QA/QC of our select manufacturers based on their ability to meet the performance specifications consistently • Competitive price with lower operating and life cycle costs • Equal to or better performance for the dosage • Process performance guarantees available • Extensive technical and resin application support • Annual resin analysis – No Charge • Custom packaging to meet your volume needs • Certificates of Analysis, Certificates of Conformance and shelf life statements are available • QA/QC meets ANSI/ASME NQA-1, 10CFR50 (Appendix B), and 10CFR21 compliance to Nuclear Safety requirements See page 99 for catalog information. See page 219 for turnkey ion exchange resin services. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 99 ION EXCHANGE RESINS AND FILTER MEDIA USF™ Ion Exchange Resin and Media Ion Exchange Resins PRODUCT NAME CATALOG # DESCRIPTION USF C-211 (NA) 109104110 8% cross-linked, standard sodium form USF C-211 (H) 109104111 8% cross-linked, standard hydrogen form USF C-361 (NA) 109000902 10% cross-linked, more durable cation, sodium form USF C-361 (H) 109000010 10% cross-linked, more durable cation, hydrogen form USF C-381 (NA) 109001162 20% cross-linked, macroporous cation, sodium form USF C-381 (H) 109000050 20% cross-linked, macroporous cation, hydrogen form 109004281 Acrylic weak acid cation macroporous, hydrogen form USF A-244 (CL) 109151000 Type II strong base, gel standard anion, chloride form USF A-284 (CL) 109167502 Type I strong base, gel standard anion, chloride form USF A-464 (CL) 109183201 Type I strong base, porous gel standard anion, chloride form USF A-674 (CL) 109001160 Type I strong base, macroporous standard anion, chloride form USF A-714 (CL) 109004968 Strong base acrylic gel anion, chloride form USF A-399 (FB) 109183401 High capacity styrenic macroporous weak base anion, free base form USF A-444 (FB) 109000706 High capacity acrylic gel weak base anion, free base form USF C-361 MEG (H) 3R0100029 10% cross-linked cation, hydrogen form, specially processed to meet tight semiconductor industry requirements USF C-361 MEG PPQ (H) 3R0100028 Extremely low sodium processed upgrade of the C-361 MEG (H). USF A-464 MEG (OH) 3R0100652 Type I strong base, porous gel anion, hydroxide form, specially processed to meet tight semiconductor industry requirements USF A-464 MEG PPQ (OH) 3R0100653 Extremely low sodium processed upgrade of the A-464 MEG (OH). USF NR-30 MEG 3R0101082 1:1 chemical equivalent mix of C-361 MEG (H) and A-464 MEG (OH) USF NR-30 MEG PPQ 3R0101086 1:1 chemical equivalent mix of C-361 MEG PPQ (H) and A-464 MEG PPQ (OH) Strong Acid Cation Weak Acid Cation USF C-271 (H) Strong Base Anion Weak Base Anion MEG Grade Resins Cation Anion Mixed Bed ORDERING INFORMATION Please contact Technical Support at, 800.875.7873 ext 5000 for more information. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 100 ION EXCHANGE RESINS AND FILTER MEDIA USF™ Ion Exchange Resin and Media Filter Media and Activated Carbon Quartz USF No. 20 Quartz 110001500 Underlayment support bed and/or filter media: 0.4-0.5 mm USF No. 7 Quartz 110001401 Underlayment support bed and/or filter media: 0.75-0.85 mm USF No. 4 Quartz 110001302 Underlayment support bed and/or filter media: 1.50-1.60 mm USF 1/4 x 1/8 Quartz 110001203 Underlayment support bed and/or filter media: 3.2-6.4 mm USF 1/2 x 1/4 Quartz 110001104 Underlayment support bed and/or filter media: 6.4-12.7 mm USF 3/4 x 1/2 Quartz 110001005 Underlayment support bed and/or filter media: 12.7-19.1 mm USF No. 8 Garnet 110400002 Filter media: 2.10-2.50 mm USF No. 8-12 Garnet 110400000 Filter media: 1.41-2.00 mm USF No. 30-40 Garnet 110400001 Filter media: 0.35-0.50 mm 110201001 Manganese greensand used for iron removal 110100997 Coarse filter media USF ORC Carbon 110350006 12x40 mesh bituminous activated carbon USF Acid Washed Carbon 110350008 Acid washed 12x40 mesh bituminous activated carbon USF Coconut Shell Carbon 110350009 Coconut Shell 12x40 mesh activated carbon Garnet Manganese Greensand USF Greensand Anthracite USF Anthrafilt Activated Carbon ORDERING INFORMATION Please contact Technical Support at, 800.875.7873 ext 5000 for more information. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 101 ION EXCHANGE RESINS AND FILTER MEDIA USF™ Ion Exchange Resin and Media Cross Reference Guide Siemens is the largest distributor of ion exchange resin. We are able to supply you resin from all of the leading manufacturers, and are the largest stocking distributor of Dowex brand resin. USF™ Brand Amberlite Rohm & Haas Lewatit LANXESS Ionac® Sybron Diaion® Mitsubishi Dowex® Dow Purolite® Weak Acid Cation USF C-271 IRC-76 USF C-281 IRC-86 MAC-3 (Marathon® MAC-3) CNP-80 CC WK-40 C-106 C-105 Strong Acid Cation USF C-211 IR-120 (Amberjet® 1200) (MonoPlus® S-100) C-249 SK-1B HCR-S (Marathon® C) C-100 USF C-361 IR-122 (Amberjet® 1500) (MonoPlus® S-200) C-250 SK-110 HGR-W2 (Marathon® C-10) C100X10 USF C-381 IR-200 (MonoPlus® SP-112) PK-228 (Marathon® MSC) C-150 WA-30 (Marathon® WBA-2) A-100 Weak Base Anion USF A-399 IRA-96 (MonoPlus® MP-64) USF A-444 IRA-67 VP OC 1072 A-845 Strong Base Anion USF A-244 IRA-410 (Amberjet® 4600) (MonoPlus® M-600) ASB-2 SA-20A SAR (Marathon® A2) A-300 USF A-284 IRA-400 (Amberjet® 4200) (MonoPlus® M-500) ASB-1 SA-10A SBR-C (Monosphere® 550A) A-600 USF A-464 IRA-402 (Amberjet® 4400) ASB-1P SA-12A SBR-P (Marathon® A) A-400 USF A-674 IRA-900 (MonoPlus® MP-500) A-641 PA-312 (Marathon® MSA) A-500 A-714 IRA-458 VP OC 1071 A-850 Mixed Bed USF TM-9 NRW-37 USF EDM USF NR-6 IRN-150 SM 94 USF NR-14 NM-60 (Marathon® MR-3) NM-73 NRW-37 USF NR-30 EX MB ( ) indicates Uniform Particle Size Equivalent ORDERING INFORMATION Please contact Technical Support at, 800.875.7873 ext 5000 for more information. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 102 ION EXCHANGE WASTEWATER SYSTEMS Wastewater Ion Exchange Systems Siemens Water Technologies designs and maintains systems to purify metal finishing rinses, contaminated groundwater, printed circuit board rinses and many other metal bearing streams. Siemens’ Wastewater Ion Exchange (WWIX) service utilizes ion exchange resins and other media selected to remove specific ionic contaminants from groundwater, industrial wastewater, and process water for recycle. DOT approved vessels containing the selected resin or media treat your water until the capacity is reached. Once exhausted, the WWIX vessels are removed and replaced with fresh, DOTcompliant vessels and returned to service. Exhausted vessels are returned to our processing facility where the contaminants are removed from the media/resin. Your specific requirements are evaluated on an individual basis to determine the system configuration that best meets your current and future needs. The system components are selected based upon your specific reuse or discharge requirements. If your needs change, our wastewater treatment systems are flexible – we can simply change the media types and/or tank size saving you significant capital expense. Systems include resin/media options matched to your treatment needs: • Granular Activated Carbon – Removes potential organic foulants as pretreatment to the resins • Strong Acid Cation Resin – Removes soluble cations (Ca, Ni, Zn, Mg, Cu, etc.) • Strong Base Anion Resins – Removes soluble anions (SO4, Cl, CN, Cr6, etc.) • Mixed Bed Resin – For polishing of low level dissolved ionic waters (e.g. rinse applications) • Metals Specific Resins – For removal of specific metals (Cu, As, Zn, etc.) • Lead Resins – For removal of Pb from wastewaters (sacrificial media) Siemens national service network provides the local service needed to simplify the operation of your WWIX system. A simple phone call is all that is required to get fresh canisters delivered to your site and the spent units picked up and returned to our RCRA permitted plant for processing. All of our tanks are DOT approved for the transportation of hazardous waste. See page 217 for more details on this service. Resin Capacity (ft3) 0.45 1.2 3.5 12 30 Flow Rate (Min.–Max.) 0.5–1 1–3 2–10 10–35 25–75 8”dia./20.5” 8”dia./48” 14”dia./50” 29”sq./71.5” 36”sq./75.5” Dimensions, Base/Height Siemens Water Technologies 24-hr Customer Service: 800.466.7873 ORDERING INFORMATION For more information, contact 800.525.0658. BACK Section Table of Contents ION EXCHANGE WASTEWATER SYSTEMS 103 AquaSaver™ Chemical Feed and Pump Skids AquaSaver™ control skids are totally integrated, skid-mounted treatment stations for pre ion-exchange water conditioning. The pH Contol Skid adjusts the pH to the proper level before transfer to the ion exchange system, while the Booster Skid supplies consistent process water flow and pressure, optimizing the operation of downstream ion-exchange systems. SPECIFICATIONS Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 75 gpm pH Monitor . . . . . . . . . . . . . . . . . . . . . . . . Strantrol® 880 PLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Allen-Bradley® Chart Recorder . . . . . . . . . . . . . . . . . . . . . Optional Chemical Pumps . . . . . . . . . . . . . . . . . . . Siemens or LMI® Alarms Beacon and Audible Alarm for out of spec conditions ORDERING INFORMATION For more information, contact 800.525.0658. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 104 LABORATORY WATER SYSTEMS PURELAB® Ultra Water Purification System State-of-the-art intelligent water system delivers ASTM Type I ultrapure water for critical biological and analytical applications. Designed to ensure the highest quality water with the most advanced smart monitoring system. Standard Features and Benefits • 18.2 Megohm purity water up to 2.0 lpm • Direct on-line real time TOC monitoring (Analytic and Genetic) • Unique CID (cartridge identification) technology provides full traceability and history of purification cartridge packs for validation • 5 models to choose from • Worker polisher purification design reduces annual costs by 50% • Programmable dispense with auto alarm and shut off prevents flooding • Volumetric Profile Memory dispense • Friendly consumable change-out reminders PURELAB® ULTRA SYSTEM SPECIFICATIONS Performance Specifications* MODEL PURELAB Ultra Scientific PURELAB Ultra Ionic PURELAB Ultra Analytic PURELAB Ultra Bioscience PURELAB Ultra Genetic System Dimensions Resistivity Flow Rate (lpm) 18.2 18.2 18.2 18.2 18.2 up to 2.0 up to 2.0 up to 2.0 up to 2.0 up to 2.0 * Specifications based on RO pretreatment ** < 1 CFU/ML w/0.2µm filter TOC (ppb) 3-10 3-10 1-2 3-10 1-3 Endotoxins EU/ml NA NA NA <0.001 <0.001 Bacteria CFU10/ml <1** <1 <1 <1 <1 Weight lbs HxWxD (in) MODEL PURELAB Ultra Scientific PURELAB Ultra Ionic PURELAB Ultra Analytic PURELAB Ultra Bioscience PURELAB Ultra Genetic 19x16x14 19x16x14 19x16x14 19x16x14 19x16x14 38 39 40 39 40 Feed Water Parameters Purification Technology Maximum Fouling Index Maximum Conductivity (RO Feed) Minimum Resistivity (SDI Feed) Maximum TOC Maximum Free Chlorine Maximum Carbon Dioxide Maximum Silica Particulates Temperature Feedwater Flow Rate Maximum Pressure Minimum Pressure <1* MODEL Dual 50 µS/cm Purification Cartridges 1 MΩ-cm 50 ppb PURELAB Ultra Scientific l <0.05 ppm PURELAB Ultra Ionic l 30 ppm PURELAB Ultra Analytic l 2 ppm PURELAB Ultra Bioscience l Down to 0.2 µm filtration PURELAB Ultra Genetic l 1-40 °C Maximum requirement 130 lph 10 psi 1 psi or flooded suction to the recirculation pump Power Requirements 100-240 VAC, 50-60 Hz (all models) *A 0.2µm prefilter recommended for all non-RO feeds. UV 254nm l UV 254/185nm l l UF Ultrafilter l l Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents UMF Ultra Microfilter l l TOC Monitor l l 105 LABORATORY WATER SYSTEMS ‘ PURELAB® Ultra Water Purification System Applications Invitro Fertilization 2D Electrophoresis Glassware washing HPLC PURELAB Ultra Scientific PURELAB Ultra Ionic l l Immunology Microbiology Buffer Preparation Toxicology l l GC/MS Tissue Culture l l Flameless AA Ion Chromatography Protein/Peptide Sequencing Monoclonal Antibody production Endotoxin analysis DNA/RNA Research PCR l ICP-MS Protein purification Atomic Absorption ICP-ES PURELAB® Ultra Systems ORDERING INFORMATION MODEL PURELAB Ultra Scientific PURELAB Ultra Ionic PURELAB Ultra Analytic PURELAB Ultra Bioscience PURELAB Ultra Genetic PURELAB Ultra Analytic under-bench system (with remote control station and dispense gun) PURELAB Ultra Genetic under-bench system (with remote control station and dispense gun) PURELAB Ultra Bioscience PURELAB Ultra Genetic l l l l l l l l TOC Analysis Mammalian Cell Culture PURELAB Ultra Analytic l l l l l l l l Consumables and Accessories Catalog Number ULXXXSCM2 ULXXXIOM2 ULXXXANM2 ULXXXBSM2 ULXXXGEM2 ULRSXANM2 ULRSXGEM2 Service and Maintenance packages available DI (Deionization) Cartridges must be ordered separately Consumables Sanitization Tablets UV Lamp 254nm (for Ionic) UV Lamp 185nm/254nm Ultra microfilter (0.05µm) Ultrafilter (5,000 MWCO) Point-of-Use Filter (0.2µm) Labpure S1 DI Cartridge-RO Feed Labpure S2 DI Cartridge-SDI Feed Labpure S3 DI Cartridge-Low Ionic Labpure S4 DI Cartridge-Low TOC CT1 LC105 LC118 LC109 LC151 LC134 LC182 LC183 LC184 LC185 Accessories Pressure Regulator Valve Inlet Wall Mounting Kit (PURELAB Ultra Unit) RS232 Printer Kit Installation Kit (PURELAB Ultra Unit) (supplied) Remote Dispense Station (including dispense gun) Integral Dispense Gun (PURELAB Ultra Unit) Remote Control Station (PURELAB Ultra Unit) Open Circuit Ring Main Kit Closed Circuit Ring Main Kit Pressure Regulator <60 psd SDIRG2613* LA622USA LA618 LA642 LA643 LA644 LA645 LA646 LA647 LA652 Storage reservoirs are located on pages 34. * For feed pressure above 60 psig, use pressure regulator LA575. Note: Installation kit supplied with all Ultra systems PURELAB® Systems Validation Support Siemens Water Technologies offers validation documentation support packages for all PURELAB® Ultra water purification products. Validation support manuals include Installation Qualification (IQ), Operational Qualification (OQ) documentation and other quality certification as required to complete validation of the water system. Our service engineers are fully trained to perform certification as required to complete the validation of water system. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 106 LABORATORY WATER SYSTEMS ‘ PURELAB® Classic Water Polishing Systems Cost-efficient alternative for ASTM Type I purity water for general analytical and biological applications. The PURELAB® Classic System offers reliability, and uncompromising water quality. Standard Features and Benefits • 18.2 Megohm purity water up to 1.5 lpm • Easy front loading cartridges • Complete sanitization of all wetted parts • Unique CID Technology provide full traceability and history of purification cartridge packs for validation • Dual wavelength UV — 185 nm and 254 nm (PURELAB Classic UV Model) • 5000 Dalton UF Module for pyrogen removal (PURELAB Classic UF Model) • Wall or bench mountable • Applications include HPLC, ICP, ICP/MS, GC, IC, AA, cell culture and molecular biology PURELAB® CLASSIC SYSTEMS System Specifications MODEL PURELAB Classic DI PURELAB Classic UV PURELAB Classic UF PURELAB Classic UV/UF Resistivity Flow Rate† (lpm) TOC* (ppb) Endotoxins** EU/ml Bacteria** CFU/ml 18.2 1.5 <3-10 NA <1 18.2 1.5 <1-3 NA <1 18.2 1.5 <3-10 <.001 <1 18.2 1.2 <1-3 <.001 <1 * Depends on feed water conditions. ** Based on regular sanitization and proper maintenance of the system. † Based on 1 bar feed pressure. System Dimensions MODEL HxWxD (in) PURELAB Classic DI 19x16x14 PURELAB Classic UV 19x16x14 PURELAB Classic UF 19x16x14 PURELAB Classic UV/UF 19x16x14 Weight (lbs) 32 33 32 33 Feed Water Parameters Operating Temperature PURELAB Classic DI 1–40˚ C PURELAB Classic UV 1–40˚ C PURELAB Classic UF 1–40˚ C PURELAB Classic UV/UF 1–40˚ C MODEL Inlet Connections 8mm (5/16”) OD-Quick Connect 8mm (5/16”) OD-Quick Connect 8mm (5/16”) OD-Quick Connect 8mm (5/16”) OD-Quick Connect Inlet Pressure 1–10 psig 1–10 psig 1–10 psig 1–10 psig Power Requirements 110–240 V 50/60 Hz 110–240 V 50/60 Hz 110–240 V 50/60 Hz 110–240 V 50/60 Hz Free Chlorine (ppm) <0.05 <0.05 <0.05 <0.05 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 107 LABORATORY WATER SYSTEMS ‘ PURELAB® Classic Water Polishing Systems Consumables Chlorine Sanitization Tablets Labpure S5 DI Cartridge UF Membrane UV Lamp 185/254 nm 0.2 µm Final Filter CT1 LC186 LC169 LC170 LC134 Accessories Integral Dispense Gun Remote Dispense Station Printer Kit Sanitization by-pass block Pressure Regulator Valve (Feed Water Pressures >4 bar (60 psi)) Pressure Regulator Valve (Feed Water Pressures >0.7 bar (10 psi)) Pressure Regulator <60 psi Wall Mount Kit Remote Dispense Station with Dispense Gun Open Ring Main Kit Closed Ring Main Kit Installation Kit Composite Vent Filter LA644 LA645 LA618 LA698 LA575 LA652 SDIRG261 LA622USA LA643 LA646 LA647 LA642 LC136M2 PURELAB® CLASSIC SYSTEM ORDERING INFORMATION MODEL PURELAB Classic DI PURELAB Classic UV PURELAB Classic UF PURELAB Classic UV/UF Catalog Number CLXXXDIM2 CLXXXUVM2 CLXXXUFM2 CLXXUVFM2 Purification Cartridges must be ordered separately. UF cartridge and UV lamp supplied. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 108 LABORATORY WATER SYSTEMS ‘ PURELAB® UHQ Systems Lightweight, compact, portable ultrapure water system for the modern laboratory requiring up to 15 liters per day of 18.2 Megohm ASTM Type I water. The PURELAB® UHQ System delivers ultrapure water from a tap feed or pretreated feed source for demanding laboratory applications. Standard Features and Benefits • 18.2 Megohm purity water up to 0.75 lpm • Recirculation feature maintains optimum water quality and inhibits bacterial growth • Specially conditioned ion exchange resin ensures absolute ionic purity • UV reactor cell reduces microorganisms and TOC levels • 0.05 µm absolute filter protects microbore columns in analytical instruments • Quality meter continually displays resistivity of water • 4 liter storage tank capacity • Supplied complete with all consumables Application HPLC Atomic Absorption Spectroscopy ICP/MS PURELAB® UHQ SYSTEM SPECIFICATIONS Ion Chromatography PURELAB UHQ II l l l l PURELAB UHQ PS l l l l Performance Specifications MODEL PURELAB UHQ II w/RO PURELAB UHQ PS w/out RO * When fed with reverse osmosis (RO) water System Dimensions MODEL PURELAB UHQ II PURELAB UHQ PS Particles TOC (ppb) <20 <20* HxWxD (in) <0.05 µm <0.05 µm Shipping Weight (lbs) 16x9x16 16x9x16 PURELAB UHQ II PURELAB UHQ PS Feedwater quality PURELAB® UHQ SYSTEMS ORDERING INFORMATION MODEL Operating Temperature Potable water free from turbidity & organics (max. free chlorine <0.1 ppm Prepurified, <20 µS/cm and filtered to 0.2 µm or less PURELAB UHQ II Type I water system w/RO PURELAB UHQ PS Type I water system w/out RO Inlet Connections 3/4" NPT or 3/8" tube 3/4" NPT or 3/8" tube 22 22 PURELAB® UHQ Feed Water Parameters MODEL Output/per 8 hr day when fed w/RO water 15 liters 25–40 liters Bacteria CFU/ml <1 <1 Power Requirements 110/115 V 60 Hz 110/115 V 60 Hz Inlet Pressure 4–35˚ C Max 90 psi/Min 30 psi 4–35˚ C Max 90 psi/Min 30 psi Consumables and Accessories Catalog Number UHQ000IIXX11503 UHQ000PSXX11503 Purification Pack (2 organic absorption cartridges and 2 ion exchange cartridges) Reverse Osmosis Cartridge 0.05 µm Ultra Microfilter UV Lamp Composite Vent Filter Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents UHQPACKA UHQ5 LC109 LC104 UHQ4 109 LABORATORY WATER SYSTEMS ‘ MODULAB® High Flow Systems Modular polishing system provides up to 18.2 Megohm quality water on demand. The MODULAB® High Flow System is offered in three models: low TOC (Total Organic Carbon), low bacteria, low pyrogen systems. Features and Benefits • High capacity, low TOC cartridges • Flow rates up to 14 lpm • Dual wavelength UV sterilization • Wall mountable • Up to 18.2 MΩ-cm water MODULAB® HIGH FLOW SYSTEMS Ordering Information MODEL # MHF0ORG1 MHF0SMF2 MHD0SMF5 CARTRIDGES MLHF20DI01 MLHF20CAR1 MLHF20OS01 FCUF020S2 (1/PK) MLMF020S2 (2/PK) FCUF020S05 CONSUMABLES BULBUV185 MLHFTOC1KIT MLHFB102 MLHFUF05 PRODUCT Modulab High Flow System Low TOC Modulab High Flow System Bio Model Modulab High flow System UF Model Carbon Cartridge Mixed Bed Cartridge Organic Removal Cartridge 0.2 µm, Filter Cartridge 0.2 µm, Filter Cartridge 0.05 µm, Micro Ultrafilter Cartridge UV Lamp Start-up Kit (Low TOC) Start-up Kit (Bio Model) Start-up Kit (UF Model) General Specifications Operating Parameters Min Feed Pressure Max Feed Pressure Min Feed Temperature Max Feed Temperature Physical Specifications Length, in (cm) Depth, in (cm) Height, in (cm) UV Bulb Service Clearance, in (cm) Utility Requirements Electrical Low voltage service, Single Phase Breaker required per Code Feed Water 0.5 psig 60 psig 41˚F (5˚C) 100˚F (37.7˚C) 43 (109) 8.5 (22) 39 (100)* 6 (16) Front 115 VAC 15 AMP RO or DI water * Requires an additional 4” in height to allow changing of cartridges MODULAB® System Specifications Product Water Quality Min. Flow Rate Max Flow Rate Resistivity Total Organic Carbon (TOC) Heavy Metals Bacteria Endotoxin 2 lpm (0.5 gpm) Up to 14 lpm (3.7 gpm) Up to 18.2 MΩ-cm @ 25˚C <15 ppb* <0.10 ppb <10 cfu/ml** <0.05 EU/ml** * With organic Removal Cartridge installed and RO (reverse osmosis) feed water. ** With Sub-micron or UF (ultrafiltration) Filter Cartridge installed as specified. Note: Specifications are based on a RO feed with recirculation. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 110 LABORATORY WATER SYSTEMS ‘ PURELAB® Option-S Water Purifiers The PURELAB® Option-S System combines pretreatment, reverse osmosis, and ionic/organic removal in a single unit to deliver better than single distilled quality water from a potable water source. With 4 models to choose from, the PURELAB® Option-S System is ideally suited for general laboratory analyses and as pretreatment to ultrapure water polishing units. Standard Features and Benefits • Up to 10 Megohm purity water • Easy front loading cartridges • Cartridge change indicator • Microprocessor controlled system management with continuous water quality monitoring • Data collection capabilities through RS232 interface • Adjustable audio-visual alarms • Upgradable to higher flow rates • Wall or bench mountable • Supplied complete with all consumables PURELAB® OPTION-S SYSTEM SPECIFICATIONS Performance Specifications MODEL PURELAB Option-S 7/15 PURELAB Option-S 30/60 Bacteria* CFU/ml Resistivity MΩ-cm TOC (ppb) <30 <50 1–10 1–10 * Based on regular sanitization and proper maintenance of the system System Dimensions MODEL PURELAB Option-S 7 PURELAB Option-S15 PURELAB Option-S 30 PURELAB Option-S 60 HxWxD (in) MODEL PURELAB Option-S 7/15 PURELAB Option-S 30/60 Feed Water Potable Potable Power Requirements 110–240 V 50- 60 Hz 110–240 V 50- 60 Hz 110–120 V 60 Hz 110–120 V 60 Hz 29.8 32 114.6 116.8 Maximum FI 10 10 Max. Conductivity µS/cm 1400 1400 7 or 15 30 or 60 Neutral Neutral Weight (lbs) 18.2x16.2x8.3 18.2x16.2x8.3 29.2x22.5x12.6 29.2x22.5x12.6 Feed Water Parameters NA <1 Flow Rate LPH @ 25˚ C pH Max. Free Chlorine (ppm) <0.5 <0.5 Temperature 1–35˚ C 1–35˚ C Max. Pressure w/out booster pump (psi) 90 N/A Max. Pressure w/booster pump (psi) 30 N/A *Fouling Index Application Glassware Washing/Rinsing Reagent Preparation Buffer Preparation General Chemistry Qualitative Analyses Feed to Environmental Cabinets PURELAB Option-S 7/15 l l l l l l PURELAB Option-S 30/60 l l l l l l Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 111 LABORATORY WATER SYSTEMS ‘ PURELAB® Option-S Water Purifiers PURELAB® OPTION-S SYSTEM ORDERING INFORMATION MODEL PURELAB Option-S 7 PURELAB Option-S 7 w/booster pump PURELAB Option-S 15 PURELAB Option-S 15 w/booster pump PURELAB Option-S 30 PURELAB Option-S 60 Catalog Number OS007XXM1 OS007BPM1 (for feed waters less than 60 psi) OS015XXM1 OS015BPM1 (for feed waters less than 60 psi) OPT030XXXX11503 OPT060XXXX11503 *Reservoir is required with Option-S (sold separately - see below) All units come complete with installation kit and full set of cartridges Consumables and Accessories Option-S 7/15 Pretreatment Cartridge RO module (7.5 lph) Purification Cartridge Composite Vent Filter Wall Mounting Bracket Chlorine Sanitization Tablets Pressure Regulator Valve Booster Pump Kit Flow Upgrade Kit (7–15 lph) RS232 Printer Kit Remote Control Station Installation Kit (supplied) Remote Dispensing Valve LC140 LC143 LC141 LC136M2 LA622USA CT1 LA512 LA609 LA604 LA618 LA624 (7/15 units only) LA513 LA521 Option-S 30/60 5 µm Carbon Filter RO Module (30 lph) RO Module (60 lph) Purification Cartridge UV Lamp Wall Mounting Bracket Cleaning Solution Elgalite RF Flow Upgrade Kit 30–60 lph Installation Kit (supplied) LC123 LC115 LC119 LC114 LC105 LA593USA SOLU30966 LA562 LA545 Storage Reservoirs - Required with system Option-S 7/15 25 Liter Reservoir 40 Liter Reservoir 75 Liter Reservoir DV 35 Docking Vessel DV 35 Liter Mounting Bracket Wall Mounting Kit (25/40 Liter Reservoir) Wall Mounting Kit (75 Liter Reservoir) LA611 LA612 LA613 LA620 LA591USA LA591USA LA592USA Option-S 30/60 40 Liter Reservoir 75 Liter Reservoir Wall Mounting Kit (25/40 Liter Reservoir) Wall Mounting Kit (75 Liter Reservoir) LA587 LA590 LA591USA LA592USA Note: Installation kit is supplied with DV Reservoirs Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 112 LABORATORY WATER SYSTEMS ‘ PURELAB® Option-R Water Purifiers The PURELAB® Option-R System features all the technologies of the S series units with the added benefit of an integral recirculation feature to deliver better than double distilled quality water from a potable water source. The PURELAB® Option-R System is ideally suited for standard laboratory techniques and as pretreatment to ultrapure water polishing units where TOC is a concern. Standard Features and Benefits • 10 to 15 Megohm purity water • Easy front loading cartridges • Cartridge change indicator • Microprocessor controlled system management with continuous water quality monitoring through unique GRID display (Option-R 7/15) • Data collection capabilities through RS232 interface • Adjustable audio-visual alarms • Upgradable to higher flow rates • Wall or bench mountable • Supplied complete with all consumables PURELAB® OPTION-R SYSTEM SPECIFICATIONS Performance Specifications MODEL Resistivity MΩ -cm PURELAB Option-R 7/15 PURELAB Option-R 30/60 Bacteria* CFU/ml TOC* (ppb) <20 <50 10 to >15 1 to >15 * Based on regular sanitization and proper maintenance of the system System Dimensions MODEL HxWxD (in) PURELAB Option-R 7/15 PURELAB Option-R 30/60 <1 <1 18.2x16.2x8.3 29.2x22.5x12.6 * Fouling Index Application Glassware Washing/Rinsing Cytology & Histology Preparations Immuno-Cytochemistry Spectrophotometry Electrophysiology Electrochemistry RIA/ELISA Flame AA General Purpose HPLC PURELAB Option-R 7/15 l l l l l l l l l Neutral Neutral >0.2 µm >0.2 µm R7–39.8 : R15–41.9 R30–116.8 : R60–119 1400 1400 10 10 Potable Potable Particulates Weight (lbs) Feed Water Parameters Max. Max. Free Feedwater Maximum Conductivity Chlorine MODEL µS/cm (ppm) FI* PURELAB Option-R 7/15 PURELAB Option-R 30/60 pH <0.5 <0.5 Temperature 1–35˚ C 1–35˚ C Flow Rate LPH @ 25˚ C 7/15 30/ 60 Power Requirements 110–240 V 50- 60 Hz 110–120 V 60 Hz Pressure w/out booster pump (psi) 90 max/60 min. NA Pressure w/booster pump (psi) 30 max/flooded suction NA PURELAB Option-R 30/60 l l l l l l l l l Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 113 LABORATORY WATER SYSTEMS ‘ PURELAB® Option-R Water Purifiers PURELAB® OPTION-R SYSTEM ORDERING INFORMATION MODEL PURELAB Option-R 7 PURELAB Option-R 7 w/booster pump PURELAB Option-R 15 PURELAB Option-R 15 w/booster pump PURELAB Option-R 30 PURELAB Option-R 60 Catalog Number OR007XXM1 OR007BPM1 (for feed waters less than 60 psi) OR015XXM1 OR015BPM1 (for feed waters less than 60 psi) OPT030PLXX11503 OPT060PLXX11503 *Reservoir is required with Option-R (sold separately) All units come complete with installation kit and full set of cartridges Consumables and Accessories Option-R 7/15 Pretreatment Cartridge RO module (7.5 lph) Purification Cartridge Composite Vent Filter Point-of-Use Filter (0.2µm) UV Lamp Wall Mounting Bracket Chlorine Sanitization Tablets Pressure Regulator Valve Booster Pump Kit Flow Upgrade Kit (7 to 15 lph) RS232 Printer Kit Remote Control Station Remote Dispensing Gun Installation Kit (supplied) LC140 LC143 LC141 LC136M2 LC145 LC105 LA622USA CT1 LA512 LA609 LA604 LA618 LA625 (7/15 units only) LA629 (7/15 units only) LA513 Option-R 30/60 5 µm Carbon Filter RO Module (30 lph) RO Module (60 lph) Purification Cartridge Point-of-Use Filter UV Lamp Wall Mounting Bracket Cleaning Solution Elgalite RF Flow Upgrade Kit 30 to 60 lph Installation Kit (supplied) LC123 LC115 LC119 LC114 LC106 LC105 LA593USA SOLU30966 LA561 LA545 Storage Reservoirs - Required with system Option-R 7/15 25 Liter Reservoir 40 Liter Reservoir 75 Liter Reservoir DV 25 Liter Docking Vessel DV 25 Liter Mounting Bracket Composite Vent Filter Wall Mounting Kit (25/40 Liter Reservoir) Wall Mounting Kit (75 Liter Reservoir) LA611 LA612 LA613 LA621 LA591USA LC136M2 LA591USA LA592USA Option-R 30/60 40 Liter Reservoir LA587 75 Liter Reservoir LA590 Composite Vent Filter LC136M2 Wall Mounting Kit (25/40 Liter Reservoir) LA591USA Wall Mounting Kit (75 Liter Reservoir) LA592USA Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 114 LABORATORY WATER SYSTEMS ‘ PURELAB® Option-Q Water Purifiers The PURELAB® Option-Q System produces ultra pure water with out the need for a prepurified feed supply. Available in two models depending on flow rate requirements, the PURELAB® Option-Q System delivers up to 18 Megohm water on demand direct from tap making it a cost effective choice for the laboratory. Standard Features and Benefits • Up to 18.2 Megohm water from tap • Cartridge change indicator to ensure optimal performance • Easy front loading cartridges • Adjustable audio-visual alarms for consumable change-outs • RS232 interface for easily downloaded data collection • Compact Design • Comes complete with all consumables PURELAB® OPTION-Q SYSTEM SPECIFICATIONS Performance Specifications Resistivity MODEL at 25˚C PURELAB Option-Q 7/15 Up to 18.2 MΩ-cm TOC (ppb) <10 Bacteria* CFU/ml with POU Filter (optional) <1 pH Effectively Neutral Particulates POU Filter (optional) >0.2 µm Flow Rate LPH@25˚C 7/15 * Based on regular sanitization and proper maintenance of the system System Dimensions MODEL PURELAB Option-Q 7 PURELAB Option-Q 15 HxWxD (in) 18.1x21.7x10.5 18.1x21.7x10.5 Feed Water Parameters Feedwater Maximum MODEL FI* PURELAB Option-Q 7/15 * Fouling Index Application Glassware Washing/Rinsing Reagent Preparation Buffer Preparation General Chemistry Qualitative Analyses Feed to Environmental Cabinets Potable 10 Weight (lbs) 39.7 41.8 Max. Conductivity µS/cm 1400 Max. Free Carbon Chlorine Dioxide (ppm) 0.5 30 Temperature 1–35˚ C Pressure w/out booster pump (psi) 90 max/60 min. Pressure w/booster pump (psi) 30 max/flooded suction min. PURELAB Option-Q 7/15 l l l l l l Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 115 LABORATORY WATER SYSTEMS ‘ PURELAB® Option-Q Water Purifiers PURELAB® OPTION-Q SYSTEM ORDERING INFORMATION MODEL PURELAB Option-Q 7 PURELAB Option-Q 7 BP w/booster pump PURELAB Option-Q 15 PURELAB Option-Q 15 BP w/booster pump Catalog Number OQ007XXM1 OQ007BPM1 OQ015XXM1 OQ015BPM1 Consumables and Accessories Consumables Pretreatment Cartridge Reverse Osmosis Cartridge Module Ion Exchange Cartridge Pack UV Lamp Point of Use Filter Chlorine Sanitization Tablets Composite Vent Filter Pretreatment Filter LC140 LC143 LC163 LC118 LC145 CT1 LC136M2 LC123 Accessories Installation Kit (supplied) Installation Kit (with saddle valve) Pressure Regulator Valve (inlet) Booster Pump Kit Wall Mounting Kit (PURELAB Option-Q) Flow Upgrade Kit (7–15l/hr) RS232 Printer Kit Remote Dispense Valve Remote Control Station Remote Dispensing Gun Prefilter if Boost Pump Fitted LA513 LA506 LA512 LA609 LA622USA LA605 LA618 LA521 LA675 LA629 LA582 Storage Reservoirs - Required with system Option-Q 7/15 25 Liter Reservoir 40 Liter Reservoir 75 Liter Reservoir DV 25 Liter Docking Vessel DV 25 Liter Mounting Bracket Composite Vent Filter Wall Mounting Kit (25/40 Liter Reservoir) Wall Mounting Kit (75 Liter Reservoir) LA611 LA612 LA613 LA621 LA591USA LC136M2 LA591USA LA592USA Reservoir is required with Option-Q unit (sold separately) All units come complete with installation kit and full set of cartridges Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 116 LABORATORY WATER SYSTEMS ‘ PURELAB® Prima 7/15/20 Reverse Osmosis Systems PURELAB® Prima reverse osmosis water purification systems deliver Type III/IV primary grade water from a tap feed. All models continuously monitor and display water quality and operational parameters, ensuring a constant supply of pretreated quality water. Prima systems are ideal as pretreatment to ultrapure water polishers or for routine glassware washing. Standard Features and Benefits • Advanced high flux TFC membranes • Easy front loading cartridges • Cartridge change indicator • Microprocessor controlled system management with continuous water quality monitoring through unique GRID display • Data collection capabilities through RS232 interface • Adjustable audio-visual alarms • Upgradable to higher flow rates • Wall or bench mountable • Supplied complete with all consumables PURELAB® PRIMA 7/15/20 SYSTEM SPECIFICATIONS Performance Specifications Inorganics MODEL PURELAB Prima 7/15/20 TOC (ppm) Up to 98% rejection (90% min) <0.1 Bacteria* CFU/ml Organics Particulates >99% rejection <5 >99% removal Flow Rate LPH @ 25˚ C 7 or 15 or 20 * Based on regular sanitization and proper maintenance of the system System Dimensions MODEL HxWxD (in) PURELAB Prima 7/15/20 18.2x16.2x8.3 Feed Water Parameters MODEL PURELAB Prima 7/15/20 Feedwater Potable 110–240 V 50- 60 Hz Prima 7–25.4 Prima 15–27.6 Prima 20–28.7 Max. Maximum Conductivity FI* µS/cm 1400 10 Power Requirements Weight (lbs) Max. Free Chlorine (ppm) <0.5 Temperature 1–35˚ C Pressure w/out booster pump (psi) 90 max/60 min Pressure w/booster pump (psi) 30 max/flooded suction *Fouling Index Application Glassware Washing Hydroponics Pretreatment to Ultrapure water systems PURELAB Prima 7 l l l PURELAB Prima 15 l l l PURELAB Prima 20 l l l Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 117 LABORATORY WATER SYSTEMS ‘ PURELAB® Prima 7/15/20 Reverse Osmosis Systems PURELAB® PRIMA 7/15/20 SYSTEMS ORDERING INFORMATION MODEL PURELAB Prima 7 PURELAB Prima 7 w/booster pump PURELAB Prima 15 PURELAB Prima 15 w/booster pump PURELAB Prima 20 PURELAB Prima 20 w/booster pump All units include installation kit and full set of cartridges Catalog Number PR007XXM1 PR007BPM1 (for feed waters less than 60 psi) PR015XXM1 PR015BPM1 (for feed waters less than 60 psi) PR020XXM1 PR020BPM1(for feed waters less than 60 psi) Consumables and Accessories Pretreatment Cartridge RO Module (7.5 lph) Wall Mounting Bracket Chlorine Sanitization Tablets Flow Upgrade Kit (7–15 lph) Flow Upgrade Kit (15–20 lph) Flow Upgrade Kit (7–20 lph) RS232 Printer Kit Pressure Regulator Raw Water Booster Pump Kit Remote Control Station Installation Kit (supplied) LC140 LC143 LA622USA CT1 LA614 LA615 LA616 LA618 LA512 LA609 LA628 LA513 Storage Reservoirs - Required with system 25 Liter Reservoir 40 Liter Reservoir 75 Liter Reservoir DV 35 Docking Vessel DV 35 Mounting Bracket Composite Vent Filter Wall Mounting Kit (25/40 Liter Reservoir) Wall Mounting Kit (75 Liter Reservoir) LA611 LA612 LA613 LA620 LA591USA LC136M2 LA591USA LA592USA Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 118 LABORATORY WATER SYSTEMS ‘ PURELAB® Prima 30/60/90/120 Reverse Osmosis Systems Designed to meet your higher water volume requirements, PURELAB® Prima reverse osmosis water purification systems provide primary grade water from a tap feed at flow rates up to 120 liters per hour. With a built-in integral booster pump, PURELAB® Prima reverse osmosis systems are ideal as pretreatment to feeding autoclaves, dishwashers or for use in environmental cabinets. Standard Features and Benefits • Auto rinse capability • Wall or bench mountable • Low energy consumption • Microprocessor based management system • Integral pretreatment • Performance indicators • Upgradable to higher flow rates • Supplied complete with all consumables PURELAB® PRIMA 30/60/90/120 SYSTEM SPECIFICATIONS Performance Specifications PURELAB Prima 30/60/90/120 Up to 98% rejection (90% minimum) Organics Bacteria* CFU/ml TOC (ppm) Inorganics MODEL >99% rejection <5 <0.1 Particulates >99% removal Flow Rate LPH @ 15˚ C 30/60/90 or 120 * Based on regular sanitization and proper maintenance of the system. System Dimensions MODEL HxWxD (in) PURELAB Prima 30/60/90/120 Weight (lbs) 29.2x22.5x12.6 Feed Water Parameters MODEL Source PURELAB Prima 30/60/90/120 Potable Maximum FI* 10 Prima 30–101.4 Prima 60–103.6 Prima 90–105.8 Prima 120–119.0 Max. Conductivity µS/cm Max. Free Chlorine (ppm) 1400 <0.5 Power Requirements 110–120 V 60 Hz Temperature 1–35˚ C Inlet Pressure (psi) 90 max/20 minimum *Fouling Index Application Glassware Washing Feed to Autoclaves Steam Generator Feed Feed to Environmental Cabinets Pretreatment to Polishers PURELAB Prima 30 l l l l l PURELAB Prima 60 l l l l l PURELAB Prima 90 l l l l l PURELAB Prima 120 l l l l l Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 119 LABORATORY WATER SYSTEMS ‘ PURELAB® Prima 30/60/90/120 Reverse Osmosis Systems PURELAB® PRIMA 30/60/90/120 SYSTEMS ORDERING INFORMATION MODEL PURELAB Prima 30 PURELAB Prima 60 PURELAB Prima 90 PURELAB Prima 120 All units include installation kit and full set of cartridges Catalog Number PRI030XXXX11503 PRI060XXXX11503 PRI090XXXX11503 PRI120XXXX11503 Consumables and Accessories 5 µm Carbon Filter RO Module (30 lph) RO Module (60 lph) RO Module (90 lph) Wall Mounting Bracket Cleaning Solution Elgalite RF Flow Upgrade Kit (30 to 60 lph) Flow Upgrade Kit (60 to 90 lph) Flow Upgrade Kit (90 to 120 lph) LC123 LC115 LC119 LC120 LA593USA SOLU30966 LA558 LA559 LA560 Storage Reservoirs - Required with system 40 Liter Reservoir 75 Liter Reservoir Composite Vent Filter Wall Mounting Kit (40 Liter reservoir) Wall Mounting Kit (75 Liter reservoir) Installation Kit (supplied) LA587 LA590 LC136M2 LA591USA LA592USA LA545 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 120 LABORATORY WATER SYSTEMS ‘ CENTRA® Packaged Central Laboratory Water Systems The Centra® Lab Central Water System combines purification, storage and distribution in a single cabinet. The compact system design incorporates, RO, UV, filters, pump and reservoir in one unit. Purified water is distributed via a loop to multiple labs and points of use in a building. Standard Features and Benefits • Flow rates of 5 gpm and 10 gpm • Consumable change reminders • Feeds multiple floors, faucets, polishers, glassware washers, autoclaves and sterilizers in a facility • Water leak detection to prevent lab flooding • Compact design for space utilization • Easy connection to Building Management System (BMS) • Validatable CENTRA® SYSTEM SPECIFICATIONS Performance Specifications MODEL CENTRA MDS CENTRA LDS CENTRA LDS-HF CENTRA RDS CENTRA RDS-HF CENTRA S-200 CENTRA S-200-HF CENTRA R-200 CENTRA R-200-HF Inorganics As per feed As per feed As per feed From feed quality up to 18.2 MΩ-cm* From feed quality up to 18.2 MΩ-cm* RO Permeate RO Permeate Up to 18.2 MΩ-cm* Up to 18.2 MΩ-cm* System Specifications MODEL CENTRA MDS CENTRA LDS CENTRA LDS-HF CENTRA RDS CENTRA RDS-HF CENTRA S-200 CENTRA S-200-HF CENTRA R-200 CENTRA R-200-HF HxWxD (in) 47x28.75x35 71.7x28.75x35 71.7x28.75x35 71.7x28.75x35 71.7x28.75x35 71.7x28.75x35 71.7x28.75x35 71.7x28.75x35 71.7x28.75x35 Feed Water Parameters MODEL CENTRA MDS CENTRA LDS CENTRA LDS-HF CENTRA RDS CENTRA RDS-HF CENTRA S-200 CENTRA S-200-HF CENTRA R-200 CENTRA R-200-HF Source Potable Potable Potable Potable Potable Potable Potable Potable Potable Weight (lbs) Empty 254 396 396 396 396 507 507 507 507 Maximum FI* n/a n/a n/a n/a 5 5 5 5 5 As per feed As per feed As per feed From feed quality to <10 ppb* From feed quality to <10 ppb* Typically <100 ppb*** Typically <100 ppb*** <10 ppb2 <10 ppb2 Weight (lbs) working 352 1124 1124 1124 1124 1279 1279 1279 1279 Conductivity µS/cm n/a n/a n/a n/a n/a 1000 1000 1000 1000 TOC As per feed As per feed As per feed <5 CFU/ml** <5 CFU/ml** <50 CFU/ml** <50 CFU/ml** <5 CFU/ml** <5 CFU/ml** Typical Loop Flow Rate**** Up to 18 L/min @ 3 Bar (45psi) Up to 18 L/min @ 3 Bar (45psi) 38L/min @ 3 Bar (45psi) Up to 18 L/min @ 3 Bar (45psi) 38L/min @ 3 Bar (45psi) Up to 18 L/min @ 3 Bar (45psi) 38L/min @ 3 Bar (45psi) Up to 18 L/min @ 3 Bar (45psi) 38L/min @ 3 Bar (45psi) Max. Free Chlorine (ppm) n/a n/a n/a n/a n/a 0.1 ppm 0.1ppm 0.1 ppm 0.1ppm Temperature 5–35˚ C (41-95˚ F) 5–35˚ C (41-95˚ F) 5–35˚ C (41-95˚ F) 5–35˚ C (41-95˚ F) 5–35˚ C (41-95˚ F) 5–35˚ C (41-95˚ F) 5–35˚ C (41-95˚ F) 5–35˚ C (41-95˚ F) 5–35˚ C (41-95˚ F) Bacteria* Particulates As per feed As per feed n/a 0.2µm filter 0.2µm filter 0.2µm filter <10 micron 0.2µm filter <10 micron Reservoir Volume 200 Liters (53 US gallons) 350 Liters (92 US gallons) 350 Liters (92 US gallons) 350 Liters (92 US gallons) 350 Liters (92 US gallons) 350 Liters (92 US gallons) 350 Liters (92 US gallons) 350 Liters (92 US gallons) 350 Liters (92 US gallons) Electrical Requirements 115V and 11F230V 110V / 60Hz 110V / 60Hz 208-230V / 60Hz 110V / 60Hz 208-230V / 60Hz 110V / 60Hz 208-230V / 60Hz 110V / 60Hz 208-230V / 60Hz Pressure 145 psi max 145 psi max 145 psi max 145 psi max 145 psi max 58 psi max 58 psi max 58 psi max 58 psi max *Subject to suitable deionization cylinder. **Subject to correct operating and maintenance procedures. ***Subject to feed water. ****Subject to distribution loop design. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 121 LABORATORY WATER SYSTEMS ‘ CENTRA® Packaged Central Laboratory Water Systems CENTRA® LAB WATER SYSTEM ORDERING INFORMATION MODEL CENTRA MDS CENTRA LDS CENTRA LDS High Flow CENTRA RDS CENTRA RDS High Flow CENTRA S200 CENTRA S200 High Flow CENTRA R200 CENTRA R200 High Flow Catalog Number CNXXXMDM1115 CNXXXLDM1115 CNHFLDM1-230 CNXXXRDM1115 CNHFRRDM1-230 CN200SDM1115 CNHFRS201-230 CN200RDM1115 CNHFRR2M1-230 Consumables and Accessories CENTRA® Lab Water System Composite Vent Filter Bacteriological Filter (0.2 µm) UV Lamp Pretreatment Filter (10 µm) 0.2 µm Filter 10” RO Module Dot Matrix Printer Kit CENTRA Remote Display High Recovery Reverse Osmosis Kit (S200 R200) CENTRA® High Flow System Composite Vent Filter UV Lamp Pretreatment Filter (10 µm) 0.2 µm Filter 20” RO Module Dot Matrix Printer Kit CENTRA Remote Display Loop Booster Pump Module High Recovery Reverse Osmosis Kit (S200 R200) Temperature Control Kit LC156 LC157 LC158 LC159 FCWNF1052 LC161 LA666 LA665 LA679 LC156 LC158 LC159 FCWNF2052 LC161 LA666 LA665 LA696 LA679 LA688 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 122 LABORATORY WATER SYSTEMS ‘ MEDICA® 7/15 Water Systems (Models S/R/D) for Clinical Analyzers Compact system utilizing pretreatment, RO, deionization, UV photo oxidation and in-line microfiltration technologies to produce CLSI (Clinical Laboratory Standards Institute) Type I water to feed chemistry and immuno-diagnostic analyzers. Available in recirculating model - MEDICA® R, degassing model - MEDICA® D or standard MEDICA® Systems. Standard Features and Benefits • 1 to 15 Megohm purity water • Flow rates from 7 lph to 15 lph • Easy front loading cartridges • Microprocessor controlled system management with continuous water quality monitoring through unique LCD display • Adjustable audio-visual alarms and cartridge change indicator • RS232 port for water quality data collection for compliance with GLP • Models available with a degassing feature (MEDICA® D 7/15) • Recirculating models available to ensure consistent purity • System includes all cartridges MEDICA® S/R/D 7/15 SYSTEM SPECIFICATIONS Performance Specifications Resistivity MΩ-cm @ 25˚ C MODEL MEDICA S 7/15 MEDICA R 7/15 MEDICA D 7/15 1–15 1–15 1–15 Flow Rate LPH @ 15˚ C <30 <30 <30 7/15 7/15 7/15 * Based on regular sanitization and proper maintenance of the system System Dimensions MODEL * Fouling Index Application Feed Water for Clinical Analyzers Power Requirements MEDICA 7–40.8 MEDICA 15–41.9 100–240 V 50-60 Hz 18.2x21.6x10.6 MEDICA 7–40.8 MEDICA 15–41.9 100–240 V 50-60 Hz MEDICA D 7/15 Potable Potable Potable <0.2 µm <0.2 µm <0.2 µm 18.2x21.6x10.6 MEDICA R 7/15 MEDICA S 7/15 MEDICA R 7/15 MEDICA D 7/15 Neutral Neutral Neutral 100–240 V 50-60 Hz 18.2x21.6x10.6 Source Particulates MEDICA 7–40.8 MEDICA 15–41.9 MEDICA S 7/15 MODEL <1 <1 <1 pH Weight (lbs) HxWxD (in) Feed Water Parameters Bacteria* CFU/ml TOC (ppb) Maximum FI* 10 10 10 Conductivity µS/cm 1400 1400 1400 Max. Free Chlorine (ppm) <0.5 <0.5 <0.5 Pressure w/out Temperature booster pump (psi) 1–35˚ C 1–35˚ C 1–35˚ C 90 max/60 min. 90 max/60 min. 90 max/60 min. Pressure w/booster pump (psi) 30 max/flooded suction 30 max/flooded suction 30 max/flooded suction MEDICA 15 MEDICA 7 l l Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 123 LABORATORY WATER SYSTEMS ‘ MEDICA® Water Systems for Clinical Analyzers MEDICA® S/R/D 7/15 SYSTEMS ORDERING INFORMATION MODEL MEDICA S 7 MEDICA S 7 w/booster pump MEDICA D 7 w/booster pump MEDICA D 7 MEDICA D 7 w/booster pump MEDICA R 7 MEDICA R 7 w/booster pump MEDICA S 15 MEDICA S 15 w/booster pump MEDICA D 15 MEDICA D 15 w/booster pump MEDICA D 15 w/booster pump MEDICA R 15 MEDICA R 15 w/booster pump Catalog Number ME007XXM1 ME007BPM1 (for feed waters of less than 60 psi) MD007BPM2 MD007XXM1 w/DV-25 MD007BPM1 w/DV-25 MR007XXM1 MR007BPM1 ME015XXM1 ME015BPM1 (for feed waters of less than 60 psi) MD015XXM1 w/DV-25 MD015BPM1 w/DV-25 MD015BPM2 MR015XXM1 (for feed waters of less than 60 psi) MR015BPM1 Consumables and Accessories Pretreatment Cartridge RO Module (7.5 lph) Purification Cartridge In-Line 0.2 µm Filter UV Lamp Wall Mounting Bracket Chlorine Sanitization Tablets Pressure Regulator Valve Booster Pump Kit Flow Upgrade Kit (7 to 15 lph) RS232 Printer Kit Remote Control Station Installation Kit (supplied) MEDICA D Degas Membrane LC140 LC143 LC141 LC125 LC105 LA622USA CT1 LA512 LA609 LA606 LA618 LA627 (7/15 units only) LA513 MEMB37275 Storage Reservoirs - One Required with System 25 Liter Reservoir 40 Liter Reservoir 75 Liter Reservoir DV 25 Liter Docking Vessel Composite Vent Filter Wall Mounting Kit (25/40 Liter Reservoir) Wall Mounting Kit (75 Liter Reservoir) DV25 Mounting Bracket LA611 LA612 LA613 LA621 LC136M2 LA591USA LA592USA LA591USA All units include installation kit and full set of cartridges Note: Some MEDICA D systems come with DV-25 Docking Vessel Reservoir. Please note above specifications. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 124 LABORATORY WATER SYSTEMS ‘ MEDICA® Pro 30/60/120 Water Systems (S/R/RE) for Clinical Analyzers The MEDICA® Pro line of water purification systems is available in four models to meet CLSI Type I water standards for clinical analyzers. The system incorporates an integral 50 liter storage reservoir, RO, DI purification, UV photo-oxidation and ultramicrofiltration technologies. Standard Features and Benefits • Xport USB device for easy download of system performance data to comply with GLP guidelines • Unique space saving design • Upgradable for higher flowrates • High capacity Protek deionization cartridges • Special E-cartridge to reduce CO2 and prolong the life of the DI packs • Leak detection with auto shut down - minimizing the risk of flooding • Emergency by-pass loop provides an uninterrupted supply of pure water in an emergency MEDICA® PRO S/R/RE SYSTEM SPECIFICATIONS Performance Specifications MODEL Inorganics MΩ-cm @ 25˚ C (77˚ F) TOC (ppb) Silica ppm Bacteria* CFU/ml >10 <30 <0.05 <1 MEDICA® Pro S/R/RE pH Particulates µm <0.05 µm Dispense Flows to analyzer Neutral 4 l/min * Based on regular sanitization and proper maintenance of the system System Dimensions MODEL MEDICA Pro-S–260.0 MEDICA Pro-R/RE –265.0 32.3x31.1x18.9 Feed Water Parameters MODEL Source MEDICA® Pro S/R/RE Potable Maximum FI* 10 30/60/120 liters per hour at 15˚C Weight (lbs) HxWxD (in) MEDICA® Pro S/R/RE Make-up Flow Rate Conductivity µS/cm 1400 Max. Free Chlorine (ppm) <0.5 Temperature 1–35˚ C Pressure 90 max/10 min. * Fouling Index Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 125 LABORATORY WATER SYSTEMS MEDICA® Pro 30/60/120 Water Systems (S/R/RE) for Clinical Analyzers MEDICA® PRO SYSTEMS ORDERING INFORMATION The MEDICA® Pro line of systems MODEL Catalog Number MEDICA Pro LPS MEDICA Pro S 30 MEDICA Pro S 60 MEDICA Pro S 120 MEDICA Pro R 30 MEDICA Pro R 60 MEDICA Pro R 120 MEDICA Pro RE 30 MEDICA Pro RE 60 MEDICA Pro RE 120 MPXXXPSM1-115 MP030SBM1-115 MP060SBM1-115 MP120SBM1-115 MP030RBM1-115 MP060RBM1-115 MP120RBM1-115 MP030REM1-115 MP060REM1-115 MP120REM1-115 Model Medica Pro-S Medica Pro-R Medica Pro-RE Medica Pro LPS Pretreatment √ √ √ Extra Capacity Pretreatment Optional Optional Optional √ √ √ √ Optional Optional √ Optional Reverse Osmosis √ √ √ Integral 50 Liter Reservoir √ √ √ √ Deionization √ √ √ √ Optional Optional Optional Optional UV Photo-oxidation √ √ √ √ Ultra-microfiltration √ √ √ √ √ √ Air Gap Degassing 2nd Deionization Cartridge Recirculation Consumables and Accessories UV lamp 254nm (destroy bacteria and help to reduce TOC levels) Ultra Microfilter 0.05 um Medpure L1 DI (Deionization) high capacity cartridge Protek L1 (high capacity adsorption pretreatment cartridge - standard size) Protek L2 (high capacity adsorption pretreatment cartridge - Large size) RO (reverse osmosis) cartridge 30 lph High flux reverse osmosis membrane RO cartridge 60 liter per hour High flux 30 liter per hour reverse osmosis membrane E-cartridge (Reduce CO2 levels to extend Medpure DI cartridge) Sanitization tablets (12 pk) Composite vent filter (maintain bacterial integrity of reservoir) MEDICA Pro - Starter Kit 1 (install kit, Protek L1, Medpure L1, 3 sanitization tablets) MEDICA Pro - Starter Kit 2 (install kit, Protek L2, Medpure L1, 3 sanitization tablets) Analyzer Feed pump 115V 60Hz High Flow Upgrade Kit for 2nd Medpure DI cartridge (includes fittings and 1 Medpure DI cartridge) E-cartridge Upgrade Kit Castors (useful for under bench installations also) LC105 LC109 LC174 LC175 LC177 LC179 LC180 LC181 CT3 LC136M2 LC188 LC189 LA632 LA700 LA701 LA704 USA Note: Cartridge starter kit must be ordered with MEDICA Systems. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 126 LABORATORY WATER SYSTEMS ‘ MEDICA® R-200 Water Purification System for High Volume Clinical Analyzers Integrated water purification system designed to provide a purified water supply to high volume clinical analyzers and laboratories with multiple analyzers. The MEDICA® R-200 System combines storage, purification and distribution in a single cabinet. Standard Features and Benefits • Delivers up to 21 lpm of CLSI type II water purity • Incorporates storage reservoir, UV, 0.2µm filter and RO technologies in one unit • Leak detection with auto shut-down prevents flooding • Full validation support documentation available to comply with regulatory standards • RS232 interface to record system performance for GLP • Integrated by-pass loop ensures a constant water supply in an emergency MEDICA® R-200 SYSTEM SPECIFICATIONS Performance Specifications MODEL MEDICA R-200 Resistivity MΩ-cm @ 25˚ C TOC (ppb) >10 <30 * Subject to correct operating and maintenance procedures System Dimensions MODEL MEDICA R-200 HxWxD (in) 71.7x28.75x35.0 Feed Water Parameters MODEL MEDICA R-200 Source Potable Maximum FI* 5 Silica ppm <0.05 Bacteria* CFU/ml <10 Particulates pH <0.2 µm Effectively Neutral Dispense Flows to analyzer Up to 21 L/min Make-up Flow Rate 200 liters per hour Operational Weight (lbs) 1190.0 Conductivity µS/cm (max) 1000 Free Chlorine (ppm) <0.2 Temperature 5–35˚ C Pressure Maximum (psi) 60 Pressure Minimum (psi) 30 * Fouling Index Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 127 LABORATORY WATER SYSTEMS ‘ MEDICA® R-200 Water Purification System for High Volume Clinical Analyzers MEDICA® R-200 SYSTEM ORDERING INFORMATION MODEL MEDICA R-200 (230 volt 50 Hz) MEDICA R-200 (115 volt 60 Hz) Catalog Number MR200DSM1-230 MR200DSM1-115 Consumables and Accessories RO Particle Pretreatment Filter UV Lamp In-line 0.2 µm Filter Composite Vent Filter Sanitization Solution (4 x 1000 ml) LC159 LC158 LC160 LC156 B10000209 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 128 LABORATORY WATER SYSTEMS – DEIONIZATION ‘ Portable Laboratory Deionization Systems The lab wall-mountable deionization systems produce flow rates of 30 to 90 liters per hour of high purity water. These systems are a cost effective alternative for small volumes of deionized water. Built in meter, color change indicators and optional resistivity meters make it easier to monitor your water quality. B114 Deionizer • Disposable cartridge system enables a quick and easy exchange when cartridge is exhausted B114 • Battery operated wall mountable system with color coded resistivity meter displays water quality Vision 125 & 250 Deionizers • Color change indicators allow users to monitor when resin exhausts and change out is required • Optional dispense gun can be connected to either system Vision 125 and 250 Micromeg Deionizer • Choice of either disposable or exchangeable deionization cartridge • Battery operated wall mountable system with color coded resistivity meter displays water quality Accessories Vision 125 & 250 Dispense Gun DSP404 Micromeg Laboratory Performance Specifications Max Operating Max Operating Pressure Temperature psi ˚C Resistivity MΩ-cm Max Flow lph B114 1-10 30 10 35 Vision 125 1-10 60 90 35 Vision 250 1-10 60 90 35 Micromeg 1-10 90 50 35 Model System Dimensions Height inches Width inches Depth inches Weight lbs B114 15 7 6 5 Vision 125 15 4 4 5.5 Vision 250 26 4 4 9 Micromeg 20 8 9 14.3 Model Siemens Water Technologies 24-hr Customer Service: 800.466.7873 For higher flowrate needs, see Service Deionization Systems, Page 182. BACK Section Table of Contents 129 LABORATORY WATER SYSTEMS – DEIONIZATION Laboratory Disposable Deionization (DI) System Disposable alternative to SDI tanks. This system is a floor mounted 0.25 cubic foot cartridge housing and cartridge combination. It is designed to provide pretreated water to a wide range of water treatment applications. Similar to SDI tanks these disposable cartridges are available in carbon media, mixed bed, cation, and anion resins. For use in: • General laboratory use • Food or beverage processors • Electronics and chemical industries • Hospitals and Universities • Pretreatment to Ultrapure water systems Standard Features and Benefits • Produces up to 18 megohm water from a potable source • Max flow: up to 2 gpm (8 lpm) • Easy top-loading cartridge with o-ring seal • Many choices of resin media options • Easy cartridge replacement with minimal spillage • Housing comes tested with 3/4” unions attached • Multiple housings can be arranged in parallel or series to meet the flow required Specification: (housing) Filter housing: 0.25 cubic feet (7 liters) Housing w/ FDA EPDM o-ring. 3/4“ bottom inlet/outlet System Performance: Feed water parameters Maximum temp: 100°F (38°C) Pressure range: 100 psig (7 bars) Height: 27.5” (69.9cm) Housing weight: 18lbs (8.1kg) Specification: (Cartridge) Height: 22 in Operational weight: 14 lbs Ordering information: Item # LAB025DDI Desc: 1/4 cubic foot Gray PVC housing w/ FDA EPDM O-ring. Consumables: Description 1/4 cu foot mixed bed deionizer cartridge for disposable DI system. 1/4 cu foot cation bed deionizer Cartridge for disposable DI system. 1/4 cu foot anion bed deionizer Cartridge for disposable DI system. Item # LABDDIMB LABDDICA LABDDIAN *custom media type cartridges available upon request. Minimum orders apply. Contact technical support at 800-875-7873 x 5000 to discuss your requirements Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 130 LABORATORY WATER SYSTEMS – DEIONIZATION LDIRS Deionization Recirculating Systems Siemens Water Technologies LDIRS Series water purification systems deliver up to 4 gpm (15 lpm) of deionized water. The system is available in two models. LDIRS03 A compact, wall mountable panel capable of supplying up to 3 gpm (11 lpm) deionized water to a small distribution loop up to 100 linear feet in length LDIRS04 A larger skid mounted system capable of supplying up to 4 gpm (15 lpm) of deionized water to a larger distribution loop up to 500 linear feet in length. NOTE: Flow rates dependent upon size and length of distribution piping loop. System Standard Features: • Dual Filtration: 1.0 micron pre-filtration and 0.2 micron final filtration • Continuous recirculation through all post treatment components including UV sterilizer and 0.2 micron final filtration • Bacteria destruct ultraviolet sterilizer (254 nm) • Built-in GFCI protection System Benefits: • Flow rates up to 4gpm • Easy Installation • Both wall panel and skid mounted system have small footprint to conserve space (additional space required for SDI components) System Specifications Model Flow Rate (max) Feed Water Pressure Feed Water Temp. LDIRS03 3 gpm (11 gpm) min. 40 psig (2.7 bar) max. 90 psig (6.2 barA) min. 50˚F (10˚C) max. 90˚ (32˚C) LDIRS04 4 gpm (15 gpm) min. 40 psig (2.7 bar) max. 90 psig (6.2 barA) min. 50˚F (10˚C) max. 90˚ (32˚C) System Dimensions Model Electrical Overall Dimensions (cm) Frame Materials Piping Materials LDIRS03 115VAC grounded receptacle 38 (86) L x 9 (23) D X 40 (102) H White Polyethylene S-80 PVC and Polyethylene Tube LDIRS04 115VAC grounded receptacle 30 (76) L x 24 (61) D X 65 (165) H Powder Coated Carbon Steel S-80 PVC Ordering Information: LDIRS Deionization Recirculation System, 3 gpm per minute max. (11 lpm max.) LDIRS Deionization Recirculation System, 4 gpm per minute max. (15 lpm max.) LDIRS03 LDIRS04 In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 131 LABORATORY WATER SYSTEMS – DOCKING VESSELS Modular Docking Vessels DV 25 and DV 35 The new DV 25 and DV 35 docking vessels are state-of-the-art high purity water storage DV 35 reservoirs specially designed to accommodate the PURELAB® Ultra, Option, Prima and MEDICA® water purification systems. The L-shaped docking vessels are designed as a base for the water purification system, resulting in one integral, compact unit, that eliminates the need for a separate reservoir and saves valuable bench space. Standard Features and Benefits • Smooth internal surfaces with no crevices to harbor bacteria • Inert polyethylene construction minimizes possibility of contamination of stored water • Sloping, self-draining base provides more complete sanitization and quicker rinse-out DV 25 time • Recirculation capability combined with composite vent filter prevents ingress of airborne bacteria and reduces CO2 levels and volatile organics within the reservoir • Built-in dispense tap (DV 35 version only) • Docking station design means no unsightly exposed interconnecting tubing or wiring Bottom: DV 25 for use with these systems only: Top: DV 35 for use with these systems only: PURELAB® Option-R 7/15 All PURELAB® Ultra Models MEDICA® 7/15 PURELAB® Prima 7/15/20 • Reservoir water level indicator PURELAB® Option-Q PURELAB® Option-S 7/15 • Wall or bench mountable • Simple “plug-in” connections allow easy connection to the water purification system for mistake-free operation PURELAB® Classic Composite Vent Filter ORDERING INFORMATION MODEL DV 25 Modular Reservoirs DV 35 Modular Reservoirs Catalog Number Wall Bracket Installation Kit Supplied w/DV 25 Supplied w/DV 35 LA621 LC136M2 LA591USA LA620 LC136M2 LA591USA TECHNICAL SPECIFICATIONS Product Codes MODEL Volume DV 25 Modular Reservoirs DV 35 Modular Reservoirs 25 Liters 35 Liters Dimensions and Weights MODEL DV 25 Modular Reservoirs DV 35 Modular Reservoirs Connections MODEL DV 25 Modular Reservoirs DV 35 Modular Reservoirs Temperature Range Flow Rate (tap dispense) 5–40˚ C 2.5 liters/min 5–40˚ C HxWxD (in) 20x21x14 20x21x14 Inlet 5/16" (8 mm) 5/16" (8 mm) N/A Weight (lbs) (kg)-empty 13.2 (6) 15.4 (7) Weight (lbs) (kg)-full Outlet 5/16" (8 mm) 5/16" (8 mm) 68.2 (31) 94.4 (42) Return 5/16" (8 mm) 5/16" (8 mm) Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 132 LABORATORY WATER SYSTEMS - WATER RESERVOIRS Stand Alone Storage Reservoirs Easy-to-use reservoir specially designed for the storage of purified water. Fully wallmountable to save valuable bench space. Standard Features and Benefits • Inert polyethylene construction minimizes the risk of organic leachables • Fully opaque to avoid algal growth • Integrated 5-level switch control to allow automatic fill-up of reservoir by lab water system • Sloping base allows complete drainage of water from reservoir • Composite vent filter eliminates contamination of water from CO2, volatile organic compounds or airborne bacteria • Available in 3 convenient sizes — 25 liter, 40 liter and 75 liter • Designed for use with PURELAB® systems RESERVOIR SPECIFICATIONS MODEL 25 Liter Reservoir 40 Liter Reservoir 75 Liter Reservoir HxWxD (in) 16x14x11 21x16x12 27x20x14 Weight (lbs) 11 lbs Empty/ 66 lbs Full 18 lbs Empty/ 106 lbs Full 26 lbs Empty/ 192 lbs Full Useable Volume 25 Liters 40 Liters 75 Liters ORDERING INFORMATION MODEL Catalog Number For use with MEDICA®, PURELAB® Prima and Option Systems LA611 (for 7 or 15 lph systems) LA612 (for 7 or 15 lph systems) LA613 (for 7 or 15 lph systems) LA587 (for 30,60 or 120 lph systems) LA590 (for 30,60 or 120 lph systems) LC136M2 LA591USA LA592USA 25 Liter Storage Vessel 40 Liter Storage Vessel 75 Liter Storage Vessel Reservoir 40 Liter Reservoir 75 Liter Composite Vent Filter (supplied) Wall Mounting Bracket (25/40 Liters) Wall Mounting Bracket (75 Liters) Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 133 LABORATORY WATER SYSTEMS – ACCESSORIES Polypropylene Carboys Convenient polypropylene carboys for storage of high purity water. Carboys come with or without spigot for ease of use. Large handles provide easy transportation in the lab. • Steam autoclavable at 121˚ C • Large handles help with pouring and carrying • Front spigot for easy dispensing Ordering Information Part # Description CARBOYPP2 Carboy 2.5 gal (10L) PP without spigot, autoclavable CARBOYPP5 Carboy 5 gal (20L) PP without spigot, autoclavable CARBOYPP2SP Carboy 2.5 gal (10L) PP with spigot, autoclavable CARBOYPP52SP Carboy 5 gal (20L) PP with spigot, autoclavable Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 134 LABORATORY WATER SYSTEMS – ACCESSORIES Polypropylene Faucets Designed for easy dispensing of deionized or distilled water where high purity is required. Reduces the risk of bacteria. • Laboratory faucets are available in countertop and wall mounted style • Available with integral vacuum breakers • Recirculating faucet available • Made from pure unpigmented polypropylene Ordering Information Part # Description LFSPRF1PP Polypro recirculating faucet, deck mount gooseneck LFSPF10VB Polypro deck mount lab faucet with integral vacuum breaker (welded assembly) LFSPF30VB Polypro deck mount lab faucet with integral vacuum breaker (threaded assembly) LFSPF20VB Polypro wall mount lab faucet with integral vacuum breaker (welded assembly) LFSPF40VB Polypro wall mount lab faucet with integral vacuum breaker (threaded assembly) LFSPF10STD Polypro faucet, gooseneck deck mount (welded assembly) LFSPF20STD Polypro faucet, gooseneck wall mount (welded assembly) LFSPF30STD Polypro faucet, gooseneck deck mount (threaded assembly) LFSPF40STD Polypro faucet, gooseneck wall mount (threaded assembly) Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 135 LABORATORY WATER SYSTEMS – ACCESSORIES TOTAL-CHECK™ 900 TOC (Total Organic Carbon) Monitor The Total-Check™ 900 TOC monitor provides a total picture of water quality. This stand alone unit can be used with any lab water purification system to continually measure the levels of organic substances in high purity water at the systems’ dispense. Total-Check™ 900 offers quick, accurate, easy to read measurements of water quality being produced. • • • • 1-999 ppb TOC levels Calibration services available Easy to read, single LCD screen Dual wavelength 185/254nm UV lamp PERFORMANCE Operating Range: Display Resolution: Repeatability: Accuracy: 1-999 ppb TOC single ppb increments +/-5% +/-15% or +/- 1 ppb (whichever is greater) WATER SAMPLE: Inlet Pressure: 70 psi MAX (4.8 bar) Temperature: 5 to 35ºC (41-95ºF) Resistivity: 15MΩ-cm@25ºC * * May also be use with sample resistivity between 5 and 15MΩ-cm@25ºC, repeatability and accuracy levels will be lower. SPECIFICATIONS: Operating Temperature: Operating Weight: Height: Width: Depth: Electrical: 15 to 30ºC 4.2lbs (1.9kg) 9.3 inches (237 mm) 6.1 inches (155 mm) 5.9 inches (150 mm) 100-230V /50-60Hz ORDERING INFORMATION: US Model TM900M001 UE Model TM900ME01 CONSUMABLES / ACCESSORIES: Replacement UV Lamp: TM900M001 Inlet / Outlet tubing: TMFTPF04949 Tube Tubing 25’: TMFTPF04945 Luer Fittings (5 pk): TMFTPF04950 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 136 LABORATORY WATER SYSTEMS – ACCESSORIES Remote Control Stations Remote user interface for the PURELAB® Prima, PURELAB® Option and MEDICA® water purification systems. Easy to use, mountable unit fully replicates the GRID (graphically intuitive display) panel providing constant water system monitoring capabilities from a remote location. STANDARD FEATURES AND BENEFITS • Replicates GRID display monitor on water purification system • Easy to read display with icons and graphical representation of the process flow • Audio visual alarms to alert user when consumables need replacing or when reservoir water level is low • Provides parallel display capabilities to simultaneously display system parameters from 2 different locations • RS232 port for connection to a printer for easy data collection of water quality and system performance for compliance with GLP guidelines • Compact size fits in any location • Wall, bench, panel, or furniture mountable offers flexibility and convenience REMOTE CONTROL STATION SPECIFICATIONS Weight (lbs) 2.2 Temperature HxWxD 4.75 x 7.90 x 2.75 5˚ C – 40˚ C Maximum Distance from Water System (Ft) 24.6 Ordering Information MODEL Catalog Number PURELAB Prima 7/15/20 RES LA628 PURELAB Option-S 7/15 RES LA624 PURELAB Option-R 7/15 RES LA625 MEDICA 7/15 RES LA627 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents LABORATORY WATER SYSTEMS – ACCESSORIES Remote Dispense Gun Premium dispense gun allows dispensing of purified water from a remote location. Ergonomic design and push and lock dispense mechanism provides comfort and drop-by-drop control of purified water while filling laboratory containers. STANDARD FEATURES AND BENEFITS • Ability to dispense up to 6 1/2 feet from the water purification system at a flow rate up to 1.5 lpm • Can be operated with optional point of use filter • Integral recirculation capability up to point of dispense when used with a water system with recirculation pump • Drop-by-drop dispense control for greater dispensing accuracy • Push back and lock dispense mechanism allows hands-free operation • Wall mountable REMOTE DISPENSE GUN SPECIFICATIONS Flow Rate (Depending on water system used) Tube Length Approx 6'.5" 0.8 –1.5 lpm Ordering Information MODEL Catalog Number Remote Dispense Gun LA629 For use with PURELAB® Option R 7/15 Remote Dispense Gun LA644 For use with PURELAB® Ultra and PURELAB® Classic Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 137 138 LABORATORY WATER SYSTEMS - FILTRATION SYSTEMS Point-of-Use High Purity Water Capsule Filters Designed to provide absolute filtration at point of dispense on laboratory ultrapure water systems or after standard service deionization systems. Disposable design makes filtration easy and convenient. Standard Features and Benefits • Available in 0.1 µm or 0.2 µm pore size ratings • Two convenient sizes — 500 cm2 and 1000 cm2 effective filtration area • Hydrophilic polyethersulfone bacterial retentive membrane–based on Brevundimonas diminuta challenge (HIMA) • Integrity tested and validated, making them ideal for pharmaceutical and microelectronics applications • Low extractable welded housing and materials—no adhesives or glues • Non-pyrogenic per USP and LAL testing CARTRIDGE SPECIFICATIONS Dimensions Filtration Area Diameter (OD) Length/in (cm) Materials Cartridge Media Operating Parameters Maximum Temperature Max. Oper. Pressure Max. Momentary Pressure Filtration Rating Toxicity Validation Recommended Water Flow Rates – gpm (lpm) 500 cm2 2.7" (6.8 cm) 4.8" (12.2) 500 1000 cm2 1000 2.7" (6.8 cm) 6.7" (16.9) Polypropylene caps, core and cage Pleated polyethersulfone Polypropylene caps, core and cage Pleated polyethersulfone 140° F (60° C) @ 30 psid (2.1 bar) 60 psid (4.1 bar) @ 20˚ C 100 psid (7.0 bar) @ 20˚ C 100% Absolute Non-toxic by USP Class VI Biological test for plastics HIMA Bacterial challenge test methods (107 organisms/cm2) 140° F (60˚ C) @ 30 psid (2.1 bar) 60 psid (4.1 bar) @ 20˚ C 100 psid (7.0 bar) @ 20˚ C 100% Absolute Non-toxic by USP Class VI Biological test for plastics HIMA Bacterial challenge test methods (107 organisms/cm2) 0.1 µm 0.2 µm 0.04 (0.16)/1 psid 0.1 (0.38)/1 psid 0.1 (0.38)/1 psid 0.3 (0.38)/1 psid 0.1 µm 0.2 µm Sanitizing Agents ≥ 90 psig (≥ 6.2 bar) ≥ 45 psig (≥ 3.1 bar) Hydrogen peroxide or autoclaved for 20 minutes at 121˚ C ≥ 90 psig (≥ 6.2 bar) ≥ 45 psig (≥ 3.1 bar) Hydrogen peroxide or autoclaved for 20 minutes at 121˚ C Integrity Test - Pore Size (Minimum Water Bubble Point) Capsule Filters 0.2 µm 1/4" NPTM x 1/4" Hose Barb Half size 0.1 µm 1/4" NPTM x 1/4" Hose Barb Half size 0.2 µm 1/4" NPTM x 1/4" Hose Barb Half size 0.1 µm 1/4" NPTM x 1/4" NPTM Half size 0.2 µm 1/4" NPTM x 1/4" NPTM Half size 0.1 µm 1/4" NPTM x 1/4" Hose Barb w/filling bell Half size 0.2 µm 1/4" NPTM x 1/4" Hose Barb w/filling bell Full size 0.1 µm 1/4" NPTM x 1/4" Hose Barb Full size 0.2 µm 1/4" NPTM x 1/4" Hose Barb Full size 0.1 µm 1/4" NPTM x 1/4" NPTM Full size 0.2 µm 1/4" NPTM x 1/4" NPTM Full size 0.1 µm 1/2" NPTM x 1/2" NPTM Full size 0.2 µm 1/2" NPTM x 1/2" NPTM Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK CW3750 FCCFH11S1 FCCFH11S2 FCCFH12S1 FCCFH12S2 FCCFH14S1 FCCFH14S2 FCCFP11S1 FCCFP11S2 FCCFP12S1 FCCFP12S2 FCCFP23S1 FCCFP23S2 Section Table of Contents 139 LABORATORY WATER SYSTEMS - FILTRATION SYSTEMS IWT® Cartridge Filtration System Convenient, economical, high quality modular water filtration system that operates on city water pressure and can easily be expanded to fit most needs. No electricity required. Up to 18 Megohm water quality can be achieved with this system. Standard Features and Benefits • Consistent source of high quality water at 50% the cost of distilled water • Removes organics, phosphates, chlorine, and essentially all ionizable constituents from water supply • Convenient color change resin to indicate resin exhaustion • Quick and easy installation • No instruments needed • Water quality up to 18 megohm-cm resistivity can be achieved • Flexible system configuration to meet specific needs SPECIFICATIONS Cartridge Adsorber Metex Universal Research Cartridge Capacity (grains as CaCO 3) Flow Rate GPH 7.2 7.2 7.2 7.2 NA 3200 1600 1000 Dimensions 3 1/2"x19 3/4" 3 1/2"x19 3/4" 3 1/2"x19 3/4" 3 1/2"x19 3/4" Shipping Weight 6 lbs single/36 lbs six pack 6 lbs single/36 lbs six pack 6 lbs single/36 lbs six pack 6 lbs single/36 lbs six pack Maximum Operating Pressure (psi) 30 30 30 30 Removal Adsorber For pretreatment of water containing organics, free chlorine, phosphate complexes, and turbidity. Universal Reduces ion concentration to a level obtainable by single distillation. All ionizable constituents are removed except free carbon dioxide and silica. Metex Research For removal of all metallic ions to a level of 1% of the influent concentration. Removes ammonia and other cations from condensate samples. Reduces ion concentration to a level obtainable by triple distillation. Essentially all ionizable constituents including silica and free carbon dioxide are removed. Applications ORDERING INFORMATION Environmental and humidity chambers Recharging lead and acid batteries for cars, fork lifts, etc Electronic cleaning equipment (with 99% isopropyl alcohol bath to wash solder trails and flux off circuit boards) Steaming devices used in food industry Photo processing and printing applications Humidifiers (including computer room humidifiers) Ice Machines Hydroponics Absorber Cartridge single pack Absorber Cartridge six pack Metex Cartridge single pack Metex Cartridge six pack Universal Cartridge single pack Universal Cartridge six pack Research Cartridge single pack Research Cartridge six pack Single assembly bracket single pack Single assembly bracket six pack Single assembly bracket with faucet adapter single pack Single assembly bracket with faucet adapter six pack Duplex assembly Bracket single pack Duplex assembly Bracket six pack Duplex assembly Bracket with faucet adapter single pack Duplex assembly Bracket with faucet adapter six pack 3C0200002 3C0200003 3C0400002 3C0400003 3C0600002 3C0600003 3C0800002 3C0800003 3C1200003 3C1200004 3C1200007 3C1200008 3C1200011 3C1200012 3C1200015 3C1200016 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 140 LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES Replacement Cartridges for Laboratory Water Purification Systems Cartridges provide ultra-high-purity water for use with MODULAB®, PURELAB®, Millipore® and Barnstead® water systems. The wide selection of cartridge styles and types allows custom-configuration of your laboratory water system to meet a variety of application needs. Standard Features and Benefits • Higher ion exchange capacity than other manufacturers’ cartridges • Lower cartridge replacement costs • Unique diffuser design for even distribution of water and maximum cartridge life • Vacuum packaging for maximum shelf life • Ultrasonic-welded seams and joints for extractable-free product water • Date coded for critical quality control • GMP cartridge manufacturing facility • Patented downflow design maximizes removal efficiency and cartridge capacity We offer the following types of resin: Activated Carbon Used for pretreating tap water before deionization. Removes traces of chlorine and organics through adsorption. Colloidal Removal Resin Removes colloids and bacteria by ion exchange and adsorption. Protects and enhances performance of deionization resin, and extends final filter life. Cation Exchange Resin Removes positively charged impurities. When used alone, this resin will lower solution’s pH. Usually used in conjunction with anion resin in a mixed bed ion exchange cartridge. Anion Exchange Resin Removes negatively charged impurities. When used alone, this resin will raise a solution’s pH. Oxygen Removal Resin Removes oxygen and prevents corrosion in water cooling loop applications. For use on feed water containing less than 10 ppm ionized solids. Mixed Bed Ion Exchange Contains a mixture of cation and anion resins in a mixed bed to purify water up to 18.2 megohm-cm. Used to polish pretreated water, or to produce high-purity water in a loop system. Organic Scavenger/Removal Resin Removes trace organics from deionized water to less than 10 ppb TOC. High Capacity Ion Exchange Combines anion and cation resin in a 2-bed configuration. Used for purifying large quantities of water at a lower purity level than provided by mixed bed deionization. May also be used to pretreat mixed-bed cartridges for longer cartridge life. Custom Cartridges Specialty resin cartridge configurations are available to meet your needs. Call our technical service department for more information. Minimum order volumes apply. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 141 LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES Replacement Cartridges for Siemens Water Technologies, USFilter® and ELGA® Laboratory Water Systems PURELAB® Ultra Water System Cartridges Ultra-microfilter Point-of-Use Filter Purification Pack-RO Feed (for MK1 Ultras) Purification Pack-SDI Feed (for MK1 Ultras) Purification Pack-Low Ionic (for MK1 Ultras) Purification Pack-Low TOC (for MK1 Ultras) Ultrafilter (5,000 MWCO) Labpure S1 DI cartridge - RO feed Labpure S2 DI cartridge - SDI feed Labpure S3 DI cartridge - Low Ionic Labpure S4 DI cartridge - Low TOC LC109 LC134 LC147 LC148 LC149 LC150 LC151 LC182 LC183 LC184 LC185 PURELAB® Classic Water System Cartridges Purification Cartridge (For MK1 Classic) Ultra Filter 5000 mwt Purification Cartridge (For MK1 Classic) Endoguard 5000 MWCO UF Cartridge (For MK1 Classic) Final Filter 0.2 µm (1/pk) Labpure S5 purification cartridge LC162 LC169 LC126 LC151 LC134 LC186 PURELAB® UHQ Water System Cartridges Reverse Osmosis Cartridge Ultra Microfilter Cartridge 0.05 µm UHQ Purification Pack (2 Organic Absorption Cartridges and 2 Ion Exchange Cartridges) Composite Vent Filter UHQ5 LC109 UHQPACKA UHQ4 PURELAB® Option Water System Cartridges Pretreatment Cartridge (Option 7 & 15) Pretreatment 5 micron Carbon Filter (Option 30 & 60) Purification Cartridge (Option R&S 7 & 15) Purification Cartridge (Option-Q 7 & 15) Purification Cartridge (Option 30 & 100) RO Module (7.5 liter/hour) — (Option 7 & 15) RO Module (30 liter/hour) — (Option 30) RO Module (60 liter/hour) — (Option 60) Point-of-Use Filter (Option 7 & 15-R) Point-of-Use Filter (Option 30 & 60-R) LC140 LC123 LC141 LC163 LC114 LC143 LC115 LC119 LC145 LC106 PURELAB® Prima Water System Cartridges Pretreatment Cartridge (PURELAB Prima 7/15/20) Pretreatment 5 Micron Carbon Filter (Prima 30/60/90/120) RO Module (7.5 liter/hour) — (Prima 7/15/20) RO Module (30 liter/hour) — (Prima 30) RO Module (60 liter/hour) — (Prima 60, 120) RO Module (Prima 90) LC140 LC123 LC143 LC115 LC119 LC120 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 142 LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES Replacement Cartridges for Siemens Water Technologies, USFilter® and ELGA® Laboratory Water Systems PURELAB® Plus Water System Cartridges PURELAB Purification Quadpack w/0.2 µm Final Filter PURELAB Purification Quadpack Endoguard 5000 MWCO UF Membrane Cartridge Final Filter 0.2 µm (1/pk) MEDICA® Water System Cartridges Pretreatment Cartridge (Medica 7/15) 5 µm Carbon Filter (Medica 30/100) Purification Cartridge (Medica 7/15) Purification Cartridge (Medica 30/100) RO Module (Medica 7/15) RO Module (30 lph) RO Module (60 lph) RO Module (100 lph) In-Line 0.2 µm Filter (Medica 7/15) In-Line 0.05 µm UMF Filter (Medica 30/100) PLC6000 PLC5000 LC151 LC134 LC140 LC123 LC141 LC114 LC143 LC115 LC119 LC137 LC125 LC109 MEDICA® Pro Water System Cartridges 0.05µm ultra microfilter Medpure L1 DI (Deionization) high capacity cartridge Protek L1 (high capacity adsorption pretreatment cartridge - standard size) Protek L2 (high capacity adsorption pretreatment cartridge - Large size) RO (reverse osmosis) cartridge 30 lph High flux reverse osmosis membrane RO cartridge 60 lph High flux reverse osmosis membrane E-cartridge (Reduce CO2 levels to extend Medpure DI cartridge) Castors (for easy mobility) LC2109 LC174 LC175 LC177 LC179 LC180 LC181 LA704USA MEDICA® R-200 Water System Cartridges RO Pretreatment Filter In-line 0.2µm Filter Composite Vent Filter Bacterial Vent Filter LC159 LC160 LC156 LC157 CENTRA® Water System Cartridges Bacterial Filter Composite Vent Filter 0.2µm Filter RO Module Pretreatment Filter LC157 LC156 LC160 LC161 LC159 MODULAB® High Flow System Cartridges Carbon Cartridge MLHF20CAR1 MLHF20OS01 MLUF020S05 MLUF020S2 Organic Removal Cartridge 0.05µm Micro Ultra Filter 0.2µm Bacteria Filter Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES Replacement Cartridges for Siemens Water Technologies, USFilter® and ELGA® Laboratory Water Systems MODULAB® Water System Membrane Cartridges 10" RO Membrane (TFC) 20" RO Membrane (TFC) 10" UF Membrane (10,000 MWCO) 10" UF Membrane (40,000 MWCO) 20" UF Membrane (40,000 MWCO) DIRO3002 DIRO3222 UFPW3308T DIUF8102 DIUF8202 MODULAB® Water System Resin Cartridges 10" Mixed Bed Cartridge (1/pk) 20" Mixed Bed Cartridge (1/pk) 10" Organic Cartridge (1/pk) 20" Organic Cartridge (1/pk) 10" Pureone Cartridge (1/pk) 10" Separate Bed DI (1/pk) 20" Separate Bed DI (1/pk) 12" Mixed Bed Cartridges (1/pk) 12" Mixed Bed Cartridges (2/pk) DIMN1000-1 DIMN2000-1 DIOR1000-1 DIOR2000-1 DIMBS1000 DISB1000-1 DISB2000-1 DIMM1200-1 DIMM1200-2 MODULAB® Carbon Cartridges 10" Carbon Cartridge (1/pk) 10" Carbon Cartridge (4/pk) 20" Carbon Cartridge (1/pk) 10" Pretreatment Carbon Cartridge/5 µm Prefilter 20" Pretreatment Carbon Cartridge/5 µm Prefilter DICR1000-1 DICR1000-4 DICR2000-1 LBCPT1002 LBCPT2004 MODULAB® Water System Cartridge Kits Modulab Cartridge Kit for RO Feed – Contains 1 EA CWCF23110,2 EA DIMN1000-1, 1 EA DIOR1000-1, 1 EA CW3750 Final Filter Modulab Cartridge Kit for DI Feed – Contains 1 EA DICR1000-1, 2 EA DIMN1000-1, 1 EA DIOR1000-1, 1EA CW3750 Final Filter Modulab UV/UF Start Up Kit 20" – Contains (1) 20" UF Membrane (40,000 MWCO), (1) 0.1 µm Capsule Filter Modulab Clinical Cartridge Kit LBMPC1006 LBMPC1005 UFSU8202 LBCCK1002 Miscellaneous Laboratory Cartridges Mixed Bed 10" cartridge PVC P-154 Mixed Bed 10" cartridge Mixed Bed 10" cartridge with porex disc, 4 pack Mixed Bed 5" cartridge with porex disc Anion Cartridge 10" Anion/Cation separate Bed 5" cartridge Anion/carbon separate Bed 10" cartridge DIMNP154 DIMN4000 DIMN1000-4PD DIMN0500-PD DIOH4000 DISB0500 DIOH4010 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 143 144 LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES LiquiPure® Replacement Cartridges for Millipore® Laboratory Water Systems LiquiPure® 1 Replacement Cartridges for Milli-Q® and Alpha-Q ™ Laboratory Water Systems The LiquiPure1 replacement cartridges for Milli-Q and Alpha-Q laboratory water systems provide ultra-high-purity water with very low TOC and extractable levels. The cartridge contains a variety of purification media to remove specific types of feed water contaminants. All wetted parts are constructed of all-natural polypropylene to minimize extractables, while a unique downflow design ensures optimum removal of organic and inorganic impurities. A pigmented polypropylene exterior prevents light from penetrating to minimize microbial growth. Cartridge contains macroreticular activated carbon, ultra-high-purity mixed bed ion exchange resin, and an organic scavenger. ORDERING INFORMATION Siemens Catalog Number Millipore Equiv. Part Number LiquiPure 1 Cartridge LP1000 LiquiPure 1 Cartridge w/0.2 µm Final Filter LP2000 Final Filter 0.2 µm (1/pk) LC134 CPMQ004R1 CPMQ004D2 CPMQK05R1 CPMQK05D2 CPMQK05RE MPGL04SK2 LiquiPure® CLC Replacement Cartridges for Millipore AFS® Analyzer Feed Systems The LiquiPure CLC replacement cartridges for Millipore AFS Analyzer Feed systems provide high-purity water to feed laboratory clinical chemistry analyzers. The cartridge contains ultra-high-purity mixed bed ion exchange resin to produce NCCLS Type 1 quality water. All wetted parts are constructed of all natural polypropylene to minimize extractables, while the unique design ensures optimum removal of inorganic impurities. A pigmented polypropylene exterior prevents light from penetrating to minimize microbial growth. Cartridge contains ultra-high-purity mixed bed ion exchange resin. ORDERING INFORMATION LiquiPure CLC Cartridge LiquiPure CLC Cartridge LiquiPure CLC Cartridge LiquiPure CLC Cartridge Siemens Catalog Number LP3000 LP3000R Millipore Equiv. Part Number CP4ALLRES LP3000R FCCFH11S2 CPAFS04R1 LP3000R & LP4000 FCCFH11S2 CP4ALLRES CPKITAFS2 LiquiPure® RO Replacement Cartridges for Millipore Milli-RO® and AFS® Systems These duplex RO pretreatment cartridges for Millipore Milli-RO and AFS Analyzer Feed systems includes granular activated carbon for chlorine removal, depth filtration for particulate removal and a food grade sequestering agent to protect the RO membrane from fouling and scale formation. Designed in a duplex configuration, the cartridge can be rotated and reconnected when one-half has been exhausted. All wetted parts are constructed of all natural polypropylene to minimize extractables, while the pigmented polypropylene exterior prevents light from penetrating to minimize microbial growth. Cartridge contains granular activated carbon, an anti-scaling agent and a prefilter. ORDERING INFORMATION LiquiPure RO Cartridge LiquiPure RO Cartridge Siemens Catalog Number LP4000 LP4000R Millipore Equiv. Part Number CPR0P0402 CPR0P0402 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 145 LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES Replacement Cartridges for Millipore® Laboratory Water Systems ORDERING INFORMATION Replacement Cartridges for Milli-Q® and Other Millipore Systems High Capacity Carbon (4/pk) Mixed Bed (2/pk), Exchange Capacity, 540 Grains as CaCO3 Organic Scavenger (1/pk) UF Membranes, 10k MW (1/pk) Prefilter 12" 5 µm 1 ea. DICM 1000-1 Carbon, 2 ea. DIMM 1200-2 Ion Exchange CWCFF 1492 Capsule Final Filter (1ea.) 1 ea. DICM 1000-1 Carbon, 2 ea. DIMM 1200-2 Ion Exchange, 1 ea. DIOM 1200-1 Organic Scavenger, 1 ea. CWCFF1492 1 ea. DICM 1000-1 Carbon, 2 ea. DIMM 1200-2, 1 ea. CWCFF1492, 1 ea. 10” Polysulfone 0.2 µm Cartridge 1 ea. FCWN12152, DICM 1000-1, DIMM 1200-1, DIOM 12001, CWCFF1492 Where Used 3, 4, 5 Bowl Milli-Q or Milli-Q Plus Systems 3, 4, 5 Bowl Milli-Q or Milli-Q Plus Systems 4 & 5 Bowl Milli-Q or Milli-Q Plus Systems 4 & 5 Bowl Milli-Q or Milli-Q Plus Systems Milli-RO® Systems 4-Bowl Life Science or 3-Bowl Standard CDFC01204 CPMB01202 CDEX01201 CDUF01201 CDPRM1206 CFUF01204 DICM1000-4 DIMM1200-2 DIOM1200-1 CDUF01201 FCR001205 LBCCM1202 4-Bowl Analytical System CFOF01205 LBRCM1002 5-Bowl Milli-Q CFIF01205 5-Bowl Milli-Q CFOF012P5 LBCCM1202 FCWN010S2 FCWN010S2 DICM1000-1 DIMM1200-1 DIOM1200-1 CWCFF1492 Millipore Equiv. Part Number Siemens Catalog Number Where Used Millipore Equiv. Part Number Siemens Catalog Number Where Used Millipore Equiv. Part Number Siemens Catalog Number Replacement Cartridges for Milli-Q® Ultrapure Water Systems Organex Cartridge Ionic Cartridge Purification Pack (Elix, RO & Distillation Feed) Purification Pack (DI Feed) Pyroguard 5000 MW Hollow Fiber UF Cartridge VOC Cartridge Pretreatment Filter Pretreatment Filter Where Used Milli-Q Academic, Biocel, Synthesis, Element, Gradient Milli-Q Academic, Biocel, Synthesis, Element, Gradient Milli-Q Academic, Biocel, Synthesis, Element, Gradient Milli-Q Academic, Biocel, Synthesis, Element, Gradient Milli-Q Biocll, Synthesis Milli-Q Academic, Biocel, Synthesis Element Gradient Milli-Q Elix 3,5,10 Milli-Q Elix 3,5,10 Replacement Cartridge Kits for Millipore Super-Q® Systems Activated Carbon (1/pk) Ion Exchange (>2000 Grain Capacity) (1/pk) Organic Scavenger (1/pk) UF Cartridges 0.22 µm Filter 20" (1/pk) Replacement RO Membranes for Millipore Milli-RO® Plus and AFS® Systems Siemens Catalog Number Millipore Equiv. Part Number 4-Bowl Super-Q (Housing #1) 4-Bowl Super-Q (Housing #2 & #3) 4-Bowl Super-Q (Housing #4) 4-Bowl Super-Q (Housing #4 optional) 4-Bowl Super-Q (Housing #4 optional) TFC RO Membrane TFC RO Membrane (w/out housing) TFC RO Membrane (w/out housing) CA Membrane Milli-RO 4 & 15 Milli-RO 6-10 and AFS Systems Milli-RO 30/60/90 Milli-RO 4 & 15 TFC RO Membrane Milli-RO 60/120 QTUM00EX QTUM00IX QGARD00R1 QGARD00D2 CDUFHF05K QTUM000VX PROG00002 PROG00001 CDFC02203 CPMB02202 CDEX02201 CDUFM2201 CVDI02TPE CDRC012S0 CDRC012HG CDRCH12HG CDRO012S0 SL2M129V8 60 - CDRC025S1 120 CDRC025S1 CDRC025SH DIMOS1201 DIMEX1201 PPMRO1201 PPMDI1201 CQUF500 DICMVOL01 PRCM1201 PRCMS001 DICM2200-1 DIMM2200-1 DIOM2200-1 CDUF02201 FCDIO20S2 ROGTM3512 LABROKIT LABROKIT ROETM3512 60 - CDRC025S1 CDRC025S1 CDRC025SH 120 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 146 LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES Replacement Cartridge kits for Barnstead® Laboratory Water Systems ORDERING INFORMATION Replacement Cartridge Kits for NANOpure™ and Other Barnstead Systems Description 1 ea. CW0835 Colloid Removal Resin, 1 ea. CW0803 High Capacity 2-Bed Resin, 2 ea. CW0809 Mixed Bed 1 ea. CW0835 Colloid Removal Resin, 2 ea. CW0809 Mixed Bed 1 ea. CW0836 Organic Removal, 1 ea. CW0820 Organic Scavenger, 1 ea. CW0809 Mixed Bed 1 ea. CW0836 Organic Removal, 1 ea.CW0803 High Capacity 2-Bed Resin, 1 ea. CW0809 Mixed Bed, 1 ea. CW0820 Organic Scavenger, 1 ea. CW0835 Colloid Removal Resin, 1 ea. CW0803 High Capacity 2-Bed Resin, 2 ea. CW5027 Mixed Bed 1 ea. CW0836 Organic Removal, 1 ea. CW0803 High Capacity 2-Bed Resin, 1 ea. CW5027 Mixed Bed, 1 ea. CW5021 Organic Scavenger, Down Flow 1 ea. CW0835 Colloid Removal Resin, 1 ea. CW0809 Mixed Bed, 2 ea. CW5027 Mixed Bed, 2 ea. CW3751 Final Filter 1 ea. CW0836 Colloid Removal, 1 ea. CW0809 Mixed Bed, 1 ea. CW5021 Organic Scavenger, Down Flow, 1 ea. CW5027 Mixed Bed, 2 ea. CW3751 Final Filter 1 ea. CW0835 Colloid Removal Resin, 1 ea. CW0803 High Capacity 2-Bed Resin, 2 ea. CW5027 Mixed Bed 1 ea. CW0835 Colloid Removal Resin, 2 ea. CW5027 Mixed Bed 1 ea. CW0836 Organic Removal, 1 ea. CW5027 Mixed Bed, 1 ea. CW5021 Organic Scavenger, Down Flow 1 ea. CW0836 Organic Removal, 1 ea. CW0803 High Capacity 2-Bed Resin, 1 ea. CW5027 Mixed Bed, 1 ea. CW5021 Organic Scavenger, Down Flow Where Used NANOpure 4 Module Type I Barnstead Equiv. Part Number D3804 Siemens Catalog Number CW3804 NANOpure 3 Module Type I D3805 CW3805 NANOpure 3 Module Type I w/ORGANICfree™ D3806 CW3806 NANOpure 4 Module Type I w/ORGANICfree D3807 CW3807 Quad Style NANOpure Type I D4801 CW4801 Quad Style NANOpure Type I w/ORGANICfree D4802 CW4802 Quad Style NANOpure Type I w/ORGANICfree D5025 CW5025 Pretreated Feed Quad Style NANOpure Type I w/ORGANICfree D5026 CW5026 Pretreated Feed E-pure™ 4 Module Type I D5028 CW5028 E-pure 3 Module Type I D5029 E-pure 3 Module Type I w/ORGANICfree D5022 CW5029 E-pure 4 Module Type I w/ORGANICfree D5023 CW5023 CW5022 Barnstead replacement cartridges continued on next page Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 147 LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES Replacement Cartridges for Barnstead® Laboratory Water Systems ORDERING INFORMATION Replacement Cartridge Kits for NANOpure™ and Other Barnstead Systems Description High Capacity, 2-Bed Ion Exchange Mixed Bed Ion Exchange Oxygen Removal Resin Activated Carbon Cation Removal Resin Organic Scavenger Resin Organic Scavenger, Down Flow Mixed Bed, Organic Removal Colloid, Organic Removal Organic Removal Oxygen Removal Mixed Bed, Oxygen Removal, Organic Removal Anion Removal Mixed Bed, Down Flow Organic Free Cartridge Organic Cartridge Kit DI Feed Pretreat Cartridge for Tap & DI Feed Ultrapure Cartridge Cartridge Kit for RO or Dist. Feed Pretreatment DI Feed Ultrapure Cartridge 0.2µm Filter Organic Free Cartridge Pretreatment Cartridge for Dist. or RO Feed Ultralow Organics Cartridge for RO or Dist. Feed Cartridge Pack Organic Free for DI Feed Sanitization Cartridge Sanitization Cartridge 5µm Cartridge Sanitization Cartridge Cartridge for RO Feed Cartridge Kit for DI Feed Where Used NANOpure, E-pure™, B-pure™, Cooling Loops NANOpure, B-pure, Older NANOpure Cooling Loops B-pure, Cooling Loops B-pure, Cooling Loops B-pure, Cooling Loops NANOpure II, Older NANOpure Systems Quad Style NANOpure, E-pure B-pure, Still Pretreatment NANOpure, B-pure, E-pure NANOpure, E-pure, Pretreatment for Organic Removal B-pure, Cooling Loops B-pure, Cooling Loops B-pure, Cooling Loops Quad Style NANOpure, E-pure NANOpure Infinity® NANOpure Infinity NANOpure Infinity NANOpure Infinity NANOpure Infinity EASYpure® EASYpure EASYpure EASYpure EASYpure Diamond™ Diamond NANOpure®, G-pure, NANOpure Infinity® NANOpure®, G-pure, NANOpure Infinity® Diamond RO, Diamond TII EASYpure Diamond Diamond Barnstead Equiv. Part Number D0803 D0809 D0811 D0813 D0815 D0820 D5021 D0832 D0835 D0836 D8809 D8811 D0760 D5027 D50252 D50254 D50251 D50253 D50257 D50230 D50233 FL703X2 D50229 D50231 D50280 D50281 D50223 D50258 D502113 D50245 D50282 D50283 Siemens Catalog Number CW0803 CW0809* CW0811 CW0813 CW0815 CW0820 CW5021 CW0832 CW0835 CW0836 CW8809 CW8811 CW0760 CW5027 CB50252 CB50254 CB50251 CB50253 CB50257 CB50230 CB50233 CB7033X2 CB50229 CB50231 CB50280 CB50281 CB50223 CB50258 CB502113 CB50245 CB50282 CB50283 * CW0809 — not for use with Bantam deionizers Reverse Osmosis Membrane DI Cartridge Remote Dispenser Cross Flow Final Filter Quad Style Replacement Ultrafilter Element for D4721 Ultrapure Ion Exchange RO MPS Cartridge Carbon Filter Deionization Deionization Prefilter, 5µm Pretreatment Carbon Cartridge Membrane 15L/hr RO Membrane UF Cartridge ULTROpure™ and ROpure™ LP EASYpure II and RF/UV Final Filters Final Filters NANOpure Quad., E-pure NANOpure Diamond RO NANOpure Diamond RO EASYpure Systems EASYpure II LF and UV ROpure Infinity ROpure Infinity ROpure Infinity NANOpure Diamond RO NANOpure Diamond RO D2732 D3750 D3751 D4722 D5021 D502114 D502115 D50229 D50245 D9004 D9005 D9006 FL1265X1 FL1192X1 CB2732 CW3750 CW3751 CB4722 CB5021 CB502114 CB502115 CB50229 CB50245 CB9004 CB9005 CB9006 CBFL1265X1 CBFL1192Y1 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 148 LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES Replacement Cartridges for Barnstead® Laboratory Water Systems Replacement Hose Nipple Cartridge Kits for Barnstead and Other Cartridge Housings Where Used Description 1/2 Size, Mixed Bed Oxygen Removal High Capacity, 2 Bed Mixed Bed Pretreatment Organic Removal Mixed Bed (No Dye) Organic Removal, Mixed Bed 2/3 Size, High Capacity Mixed Bed 180 Grains as CaCO3 1650 Grains as CaCO3 730 Grains as CaCO3 1450 Grains as NaCl to 1 megohm-cm Endpoint 730 Grains as CaCO3 575 Grains as CaCO3 1080 Grains as CaCO3 Barnstead Equiv. Part Number D8822 D8901 D8902 D8921 D8904 D8911 D8922 D8950 Siemens Catalog Number CW8822 CW8901 CW8902 CW8921 CW8904 CW8911 CW8922 CW8950 Note: Hose Nipple Cartridges are non-pressure applications; outlet must be vented to atmosphere, minimum inlet pressure should be 5 psig (0.3 bar) and designed for 3/8" H.B. (9.5mm) connection. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 149 LEAK DETECTORS DI-SDI Alert Leak Detector The DI-SDI Alert is a leak detector and alarm designed to sense deionized water leaks, initiate an alarm and activate a shut-off valve assembly (not provided). The device consists of a disk-shaped sensor that rests on the floor near the SDI tank and a receptacle mounted alarm module with an internal alarm, an external LED indicator and a 120 VAC grounded power outlet. In normal operation, the sensor detects no leak and the green LED on the alarm module remains illuminated and the 120 VAC grounded outlet remains powered. The alarm condition is initiated when the sensor detects water leakage. The red LED will be illuminated and the grounded outlet will be de-energized, thus initiating the feed water shut-off device. The DI-SDI Alert can be reset by simply shutting off the power to or unplugging the alarm module. Features & Benefits • Provides around-the-clock protection against water damage • Specially designed to sense small amounts of DI quality water • Audible alarm, visible LED warning light, reliable power cut-off • Fully automatic; failsafe operation; no maintenance Specifications Inlet Power 120V AC – 60 HZ Cable Length 12 Feet Power Output (Sensor to Alarm Module) 120V, 15 AMP resistive load, and 1/2 HP motor load Operational Warnings For indoor use only! If power to SDI leak detector is interrupted it will not function. If power to SDI leak detector is interrupted and then restored, it will reset. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 150 LEAK DETECTORS WLD Model 300A Series Water Leak Detector The Model WLD 300A is designed to detect leaks of water or other conductive fluids. The WLD 300A is a cost-effective way to monitor for leaks on or near commercial water treatment systems, or any location where an undetected leak could cause damage. The WLD 300A is designed with a number of unique features not normally found in low-cost water detection systems: SENSITIVE DETECTION SYSTEM • Designed with a sensitive detection circuit that allows detection of low conductivity fluids such as high purity water. • An integral test feature allows the user to periodically test the action of the monitor to ensure proper operation. OUTPUT FUNCTIONS • 108 dB alarm horn and LED indicators • Alarm silence and alarm reset push buttons SENSOR CALIBRATION • Two sensors may be connected in series for greater coverage • May be calibrated for local conditions REMOTE MONITORING VIA MODEM • Can be interfaced with other products to provide remote alarm notification via modem ELECTRICAL CORD OPTION • One drop cord (with standard three-prong receptacle) for the load connected to one of the control relays. ORDERING INFORMATION Catalog No. Description ALWLD300A ALWLD300AID Leak Alarm w/one sensor ALWLDAS Alarm sensor Leak Alarm w/one sensor and one drop cord receptacle SPECIFICATIONS Display: Four LED indicator lights: one for power, one for alarm condition and two for relay states. Controls: Four push button switches: alarm silence, alarm reset, calibration, and sensor test Inputs: Leak detection sensor Outputs: Alarm relay, DPDT (10 A @ 240 VAC) Control relays (2), DPDT (10 A @ 240 VAC) Horn, 108 dB Operating Temperature: 0-50˚C Operating Humidity: 0-95% RH non-condensing Power Supply: 120 VAC, 4.6 VA, 60 Hz via internal transformer. Does not include loads on output relays. Enclosure: NEMA 4X Dimensions (Overall): 6.5" x 6.5" x 4.0" Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 151 LIGHTS, QUALITY INDICATOR 5-Range Purity Light This 5-range purity indicator is ideal for monitoring product water quality from DI and other ultra-pure water purification systems. It offers 5-convenient resistivity/conductivity ranges and uses a highly visible LED indicator that changes from green to red when the product water quality falls below the selected cutoff point. SYSTEM SPECIFICATIONS Materials Body . . . . . . . . . . . . Cap material. . . . . . Sensor pins . . . . . . Power . . . . . . . . . . . . . Display. . . . . . . . . . . . . Power cable. . . . . . . . . Electrical connection . . Accuracy . . . . . . . . . . . Relative humidity . . . . . Water temperature. . . . Pressure . . . . . . . . . . . Black Noryl Clear ABS Gold-plated brass Power pak source: 115 VAC Power pak output: 6 VAC LED (one red & one green) 10' Spade lugs to screw terminals ±10% at 25°C to 90% +5°C to 45°C 0-150 psi Dimensions Height . . . . . . . . . . . . . Diameter . . . . . . . . . . . Fittings . . . . . . . . . . . . . 4.5" ± 0.5" from pins to top of cap 1.29" ± 0.25" 1/2" and 9/16" Resistivity/Conductivity Ranges Jumper Position Set Point J1 . . . . . . . . . . . . . . 50K ohms-cm (20 µS/cm) J2 . . . . . . . . . . . . . . 200K ohms-cm (5 µS/cm) J3 . . . . . . . . . . . . . . 500K ohms-cm (2 µS/cm) J4 . . . . . . . . . . . . . . 1 megohm-cm (1 µS/cm) no jumper . . . . . . . . 2 megohm-cm (0.5 µS/cm) ORDERING INFORMATION Catalog No. ZWDJ05408* ZWDJ05411* ZWDJ05421* ZWDJ05422* ZWDJ05429* ZWDJ05433* Description 5-Range Light with transformer 5-Range Light without transformer Transformer Remote 5-Range Light with 8' cord and mounting bracket Remote 5-Range Light with 50' cord and mounting bracket Remote 5-Range Light with 100' cord and mounting bracket *Not for use as final quality indicator in hemodialysis applications Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 152 LIGHTS, QUALITY INDICATOR Hy-Lite Water Quality Indicator System Inexpensive water quality indicator system to monitor DI water quality either at the DI tanks or up to 700 feet away. Features • Automatic temperature compensation • Safe 12 VDC • Easy 1/2" or 3/4" connections • Audible alarm option • Five set points available (25K, 50K, 200K, 1 meg, 2 meg ohm/cm) • Steady green/flashing red LED display • Output port for relay and remote alarm modules ORDERING INFORMATION Catalog No. ZWDJHLS025K ZWDJHLS050K ZWDJHLS200K ZWDJHLS1MEG ZWDJHLS2MEG ZWDJHLA025K ZWDJHLA050K ZWDJHLA200K ZWDJHLA1MEG ZWDJHLA2MEG ZWDJHYTRANA ZWDJHYPC ZWDJRMA ZWDJRMAR ZWDJRMR ZWDJRPCO50 ZWDJRPC100 ZWDJRPC200 Description For Use in Dialysis 25K Lite - No audible alarm 50K Lite - No audible alarm 200K Lite - No audible alarm 1Meg Lite - No audible alarm 2Meg Lite - No audible alarm 25K Lite - Audible alarm* 50K Lite - Audible alarm* 200K Lite - Audible alarm* 1Meg Lite - Audible alarm* 2Meg Lite - Audible alarm* 115VAC/12VDC Transformer Hy-Lite to Hy-Lite Patchcord Remote Alarm Module Remote Alarm Module with Auto Re-Alarm* Relay Module 50 ft. Hy-Lite to Module Cable 100 ft. Hy-Lite to Module Cable 200 ft. Hy-Lite to Module Cable *For dialysis use only, add ZWDJRMAR module for Remote Monitoring Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 153 LIQUID LEVEL CONTROLS Tank Level Controls Siemens tank level controllers are designed to control the on/off action of a water system feeding a storage tank, as well as control the on/off of a booster pump located at the discharge side of a storage tank. There are a variety of level controllers available to satisfy a wide array of application needs. • Each unit comes with three independently adjustable switches that can control the action of three devices • Switches are activated by the changing liquid level in the reservoir as sensed by the units diaphragm sensor. SYSTEM SPECIFICATIONS Pressure Connection . . . . . . . . . Electrical Connection . . . . . . . . . Switches. . . . . . . . . . . . . . . . . . . Mounting . . . . . . . . . . . . . . . . . . System Dimensions H x W x D (inches). . . . . . . . . . . ORDERING INFORMATION Catalog Number: Diaphragm . . . . . . . . . . . . . . . Bellow and Connection . . . . . . Adjustable Range . . . . . . . . . . Deadband . . . . . . . . . . . . . . . . 1/4" NPTF 3 - 7/8" diameter knockouts 3 - SPDT, 15 amp, 125/250/480 VAC In fixed position near reservoir via attached bracket 41⁄4x51⁄4x43⁄4 ZRLC02003 Buna-N #380 alloy aluminum 0-80" water column 2.0–6.0" water column ZRLC02004 Teflon® 316 stainless steel 0-80" water column 3–7" water column ZRLC02005 ZRLC02006 0.1–0.6 psi 0.1–0.6 psi Teflon® 316 stainless steel 0–20 psi Buna-N #380 alloy aluminum 0–20 psi Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 154 METERS (CONDUCTIVITY /RESISTIVITY) Thornton 200CR(S) Conductivity/Resistivity Meters The Thornton 200CR and 200CRS are flexible meters allowing the user to configure the instrument to measure in the engineering units preferred by the operator. An operator no longer needs to use one model for conductivity and another for resistivity, percent rejection (200CR) or a specific range of measurement. • Measures conductivity (1 S/cm to 0.02 µS/cm), resistivity (1.0Ω-cm to 50.0MΩcm), Temperature (–10 to 140°C and/or +14 to 284°F), TDS, (ppm/ppb), Percent rejection (0-99%), Difference (A–B, B–A), Ratio (A/B, B/A), % chemical concentration for HCl, H2SO4, NaOH. Each of two channels can be set up to measure two of these parameters. A total of four different measurements can be programmed. • Wide measurement range; Backlit LCD display • NEMA 4X housing and cable connectors. 200 foot sensor cable per channel • Designed to meet CDS/NRTL standards, calibration with NIST traceability ORDERING INFORMATION Model 200CR - Two channel monitoring Model 200 CRS - Single channel monitoring Catalog No. 200CR Res/Con Meter 115VAC . . . . . . . . . . . . 200CR Meter w/4-20 mA 115VAC . . . . . . . . . . . 200CR Meter w/4 SS Relays & 4-20 mA 115VAC 200CRS Meter w/2 Relays & 4-20 mA 115VAC 200CRS Package (w/Cord & Sensor) . . . . . . . . 0.1C Sensor 200 CR Titanium/Ryton (1.35") 3/4" NPT . . . . . . . . . . Titanium/Ryton (5.19") 3/4" NPT . . . . . . . . . . Monel/Ryton (1.35") 3/4" NPT . . . . . . . . . . . . Monel/Ryton (5.19") 3/4" NPT . . . . . . . . . . . . Titanium/PEEK (1.35) 3/4" NPT Ozone . . . . . Titanium/PEEK (5.19") 3/4" NPT Ozone . . . . Titanium/Noryl (1.14" insertion length) 1/2" NPT Titanium/Noryl (1.14" insertion length) 3/4" NPT Titanium/PEEK 1.5" Tri-clamp . . . . . . . . . . . . 316LSS/PEEK 1.5" Tri-clamp Pharm. . . . . . . Titanium/PEEK 2" Tri-clamp. . . . . . . . . . . . . . 316LSS/PEEK 2" Tri-clamp . . . . . . . . . . . . . . 200CR(S) Patch Cord 1' . . . . . . . . . . . . . . . . . . 200CR(S) Patch Cord 5' . . . . . . . . . . . . . . . . . . 200CR(S) Patch Cord 10' . . . . . . . . . . . . . . . . . 200CR(S) Patch Cord 25' . . . . . . . . . . . . . . . . . 200CR(S) Patch Cord 50' . . . . . . . . . . . . . . . . . 200CR(S) Patch Cord 100' . . . . . . . . . . . . . . . . 200CR(S) Patch Cord 150' . . . . . . . . . . . . . . . . 200CR(S) Patch Cord 200' . . . . . . . . . . . . . . . . NEMA rear enclosure . . . . . . . . . . . . . . . . . . . . Pipe mounting bracket. . . . . . . . . . . . . . . . . . . . 800 Series instrument adapter plate . . . . . . . . . High res/low cond calib kit (calib #1 & #2) . . . . Low res/high cond calib kit (calib #3 & #4) . . . . Complete calibration kit (contains all 4 calibrators) Individual calibrator #1–4 Mohm/104°C . . . . . . Individual calibrator #2–100,000 Ohm/0°C . . . . Individual calibrator #3–20,000 Ohm/104°C . . . Individual calibrator #4–1,000 Ohm/0°C . . . . . . 18.18MW-cm @ 25°C Verifier . . . . . . . . . . . . . . Siemens Water Technologies 24-hr Customer Service: 800.466.7873 ZMET62201 ZMET62221 ZMET62421 ZMET61221 ZPAK58021122 ZCEL240201 ZCEL240202 ZCEL240203 ZCEL240204 ZCEL240205 ZCEL240206 ZCEL240213 ZCEL240214 ZCEL243201 ZCEL243203 ZCEL243205 ZCEL243207 ZCOR100166 ZCOR100566 ZCOR101066 ZCOR102566 ZCOR105066 ZCOR111066 ZCOR111566 ZCOR112066 P92470 ZAC100063 ZAC100064 ZCAL186501 ZCAL186502 ZCAL186503 ZCAL186401 ZCAL186402 ZCAL186403 ZCAL186404 ZCAL186504 BACK SYSTEM SPECIFICATIONS Power . . . . . . . . . . . . . . . . . . . Operating Temp.. . . . . . . . . . . Humidity . . . . . . . . . . . . . . . . . Ranges. . . . . . . . . . . . . . . . . . Accuracy . . . . . . . . . . . . . . . . Repeatability . . . . . . . . . . . . . Temp. Accuracy . . . . . . . . . . . Relays . . . . . . . . . . . . . . . . . . Display . . . . . . . . . . . . . . . . . . Enclosure . . . . . . . . . . . . . . . . Weight . . . . . . . . . . . . . . . . . . Keypad . . . . . . . . . . . . . . . . . . Setpoints . . . . . . . . . . . . . . . . Measurement Update Rate . . . . . . . . . . . . . . Two Analog. . . . . . . . . . . . . . . Output Signals Analog Output Accuracy . . . . Serial Output . . . . . . . . . . . . . Sensor Patch Cord Length . . . . . . . . . . . . . . . . . . Temp.Compensation . . . . . . . 90-130 VAC or 180-250 VAC to 24 VDC; 12 W max; 50/60 Hz –10 to 55°C (14 to 131°F) 0-95% RH (non-condensing) High-purity – 0.1 constant cell 0.02 µS/cm to 750 µS/cm 0.0013 mΩ-cm to 50 MΩ-cm TDS: 0-62.5 k ppm (as NaCl) Temperature: -40°C to 140°C ±0.5% of reading up to 18 Magohm-cm ±0.1% for resistance and ±0.075°C for temperature ±0.25°C of reading 2 SPDT relays, each rated for max of 5 amp up to 30VDC or 250 VAC; 4 solid state, each rated for max 1.5 amp, 250 VAC 50mA min current 1 line, 16 character backlit LCD (4.8mm x 9.6mm) ABS-PC alloy; panel cut required 3.78 x 7.56" DIN 1.9 lb (0.9 kg) 11 tactile feedback keys 4 controlled setpoints can be set as low or high limit. Any setpoint can be programmed to operate up to 4 output relays. Once per second Output value is proportioned to the selected measurement signal. Outputs scaled from 4-20 mA; 500 ohm load max. 0.01 mA RS232/max distance 500 ft; RS422/max distance 4K ft. Field selectable up to 19.2 k band. Max. distance sensor to meter is 200 ft. Patch cord is required for each sensor. Automatic, reference to 25°C for resistivity, conductivity, percent rejection and TDS. Section Table of Contents 155 METERS (TOTAL ORGANIC CARBON) Thornton Total Organic Carbon System The Thornton Total Organic Carbon (TOC) system is comprised of the 770MAX multi parameter analyzer transmitter and the 5000TOC Sensor. The sensor / analyzer uses proven ultraviolet oxidation with differential conductivity to effectively measure TOC concentrations. The smart sensor design minimizes setup time to just minutes while the continuous flow design provides rapid TOC response which are far superior then traditional batch measurement systems. Benefits: • No gases or reagents to handle, store or replace. No moving parts minimize routine maintenance and service intervals. • Sensor concept allows easy and economical integration into water purification make-up and distribution systems. • Easily added to existing APEX™ or PreVUE® systems which currently use 770MAX controller • Meets USP <643>, <645> and EP 2.2.44 requirements for Pharmaceutical Industry • Ultra low TOC detection (< 1 ppb) for UPW water applications to continuously monitor critical organic levels in semiconductor make-up, distribution and process systems • Compact, sealed NEMA 4 enclosure for demanding industrial environments • 770MAX can accommodate additional sensor measurements for a total of 6 sensors including conductivity / resistivity TOC, temperature, flow, pH, DO, ORP, and ozone. SYSTEM SPECIFICATIONS Measurement Range 0.05 -1000 (ppb C) Repeatability + 0.05 ppb C < 5 ppb + 1.0% > 5 ppb Accuracy +0.1 ppb C for TOC Resolution 0.001 ppb C Analysis Time Continuous Response Time < 60 seconds Limit of Detection 0.025 ppb C Conductivity Cell Constant Accuracy +2% Temperature Sensor Pt1000 RTD, Class A Temperature Accuracy +0.25˚C @ 25˚C SAMPLE WATER REQUIREMENTS Temperature - 0 to 90˚C Particle Size - 100 micron Minimum Water Quality – 0.5 M-Ohm (2.0 vS/cm) Flow Rate – 20mL/min Pressure – 15 to 100 psig at sample inlet connection ORDERING INFORMATION Catalog No. Description Z5TOC58079510 Thornton TOC system, 110V (includes 5000TOC Sensor, 770MAX Analyzer /Transmitter, and 25" patch cord) Replacement UV Lamp ZPAK58036013 Z5TOC58091534 Z5TOC58091526 Z5TOC58091529 Z5TOC58091527 * perishable – max 4-week shelf life Standard Pharmaceutical Options System Suitability/Calibration Test kit System Suitability Standards* Calibration Standards * (500 ppb & 250 ppb) Validation Support Documents GENERAL SPECIFICATIONS Overall Dimensions – 11" W x 7.4" H x 5.25" D Sample Connections – Inlet 0.125" (3mm) O.D. compression-type (femule) tube connection with 0.25 adapter Outlet 0.25" (6mm) O.D. Barb connection Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 156 MULTIMEDIA FILTERS AVGF® Gravity Filters Flow Rates from 14 to 1,472 gpm AVGF® Gravity Filters operate automatically without a single valve, backwash pump, flow control or other instrumentation. Nothing moves but the water. The design and performance of the AVGF® filter has been proven through years of continuous use at hundreds of water treatment facilities worldwide. Widely used in pretreatment plants for boiler feedwater, generating stations, pulp and paper mills and chemical plants, the AVGF® filter is also approved by a majority of states for treatment of potable water supplies. • For process water, potable water, iron removal and cooling tower sidestreams • Requiring little labor or maintenance, the AVGF® filter operates by itself – filtering, backwashing, rinsing and returning to service without the use of valves, timers or switches • Unique design, including the discharge of filtered water above the filter bed, results in consistent high-quality effluent water • The AVGF® filter rinse water is not discharged to drain, but stored and used for the next backwash cycle to save water SYSTEM SPECIFICATIONS Model Number Flow Rate 2 gpm/sq. feet . . . . . . . . . . . . 3 gpm/sq. feet. . . . . . . . . . . . Wash Water Flow Rate. . . . . . . System Dimensions Filter Tank Diameter (feet) . . . . ......................... ......................... Pipe Size Inlet/Outlet . . . . . . . . . . . . . . . . Drain . . . . . . . . . . . . . . . . . . . . . Shipping Weight Industrial lb. kg Municipal lb. kg ............ ............ ............ ............ SYSTEM SPECIFICATIONS Model Number Flow Rate 2 gpm/sq. feet . . . . . . . . . . . . 3 gpm/sq. feet. . . . . . . . . . . . Wash Water Flow Rate . . . . . System Dimensions Filter Tank Diameter (feet) . . . . ......................... ......................... Pipe Size Inlet/Outlet . . . . . . . . . . . . . . . . Drain . . . . . . . . . . . . . . . . . . . . . Shipping Weight Industrial lb. kg Municipal lb. kg ............ ............ ............ ............ AVGF-3 14 gpm 21 gpm 147 gpm AVGF-4 AVGF-5 AVGF-6 AVGF-7 AVGF-8 AVGF-9 AVGF-10 AVGF-11 25 gpm 38 gpm 263 gpm 39 gpm 59 gpm 412 gpm 56 gpm 85 gpm 594 gpm 77 gpm 115 gpm 809 gpm 100 gpm 151 gpm 1,056 gpm 127 gpm 191 gpm 1,336 gpm 157 gpm 236 gpm 1,649 gpm 190 gpm 285 gpm 1,995 gpm 3' 4' 5' 6' 7' 8' 9' 10' 11' Remaining dimensions vary depending on type and tank diameter. Please request a product specification sheet for dimensions, overall height is 252". 2" 6" 2-1/2" 8" 3" 8" 4" 10" 4" 10" 6" 12" 6" 12" 6" 14" 8" 14" 2,600 1,179 3,400 1,542 3,500 1,588 4,200 1,905 4,400 1,996 5,400 2,450 5,400 2,449 6,500 2,948 6,300 2,858 7,500 3,402 7,300 3,311 9,000 4,082 8,500 3,856 10,400 4,717 9,700 4,400 11,500 5,216 11,200 5,080 14,100 16,396 AVGF-13 AVGF-14 AVGF-15 AVGF-16 AVGF-18 AVGF-20 AVGF-22 AVGF-25 265 gpm 398 gpm 2,787 gpm 308 gpm 462 gpm 3,232 gpm 353 gpm 530 gpm 3,711 gpm 402 gpm 603 gpm 4,223 gpm 509 gpm 763 gpm 5,345 gpm 629 gpm 943 gpm 6,598 gpm 760 gpm 1,140 gpm 7,982 gpm 982 gpm 1,472 gpm 10,300 gpm AVGF-12 226 gpm 339 gpm 2,373 gpm 12' 13' 14' 15' 16' 18' 20' 22' 25' Remaining dimensions vary depending on type and tank diameter. Please request a product specification sheet for dimensions, overall height is 252". 8" 14" 8" 15" 8" 16" 10" 18" 10" 18" 10" 20" 12" 24" 12" 24" 14" 30" 12,200 5,534 15,600 7,076 13,700 6,214 17,400 7,893 15,100 6,849 19,700 8,936 16,100 7,303 22,300 10,124 17,300 7,847 25,000 11,340 21,200 9,616 30,100 13,653 25,200 11,430 34,800 17,237 29,000 13,154 41,500 18,825 34,500 15,550 48,300 21,908 ORDERING INFORMATION Siemens Water Technologies 24-hr Customer Service: 800.466.7873 For Permutit® products and information contact 908.704.9027. BACK Section Table of Contents 157 MULTIMEDIA FILTERS KF Series Multimedia Filters Flow Rates from 1 to 70 gpm KF Series Multimedia Filters are ideal for commercial and light industrial filtration applications where the advantages of a lightweight, corrosion-resistant FRP pressure vessel and cost-effective top mounted valve are desirable. • Tank liners are blow molded plastic wrapped with high-strength epoxy resin and fiberglass for worry-free service • Includes a motorized control valve that is quiet, efficient and dependable • Electromechanical timer allows automatic backwash • Includes a pretreatment lock-out switch assembly to deactivate downstream equipment during backwash Requires field assembly. SYSTEM SPECIFICATIONS Series KFZMS Tank Size D x H (in) 10x40 12x52 14x65 16x65 18x65 21x62 24x72 30x72 36x72 Pipe Size (in) 1.0 1.0, 1.5 1.0, 1.5 1.0, 1.5 1.0, 1.5 1.5, 2.0 1.5, 2.0 2.0 2.0 APPLICATIONS Commercial RO-Feed* Service Flow Service Flow 5 gpm 8 gpm 10 gpm 14 gpm 18 gpm 24 gpm 32 gpm 49 gpm 70 gpm *Flow is based on 8 gpm/ft2 ORDERING INFORMATION Catalog Number: System Name . . . . . . . . . . . KFZMS KFZMS 4 gpm 6.4 gpm 8 gpm 11.2 gpm 14.4 gpm 19.2 gpm 25.6 gpm 39.2 gpm 56 gpm XXX Backwash Flow 8 gpm 12 gpm 15 gpm 20 gpm 25 gpm 35 gpm 45 gpm 70 gpm 100 gpm F Media Volume (ft3) 1.0 1.6 2.1 2.9 4.0 4.9 6.9 10.0 14.5 Dimensions Shipping Weight LxDxH (in) lb (kg) 10x10x50 12x12x63 14x14x76 16x16x76 18x18x75 21x21x74 24x24x90 30x30x96 36x36x97 X 160 (73) 320 (146) 469 (213) 630 (286) 670 (304) 1110 (504) 1500 (681) 1570 (713) 2130 (967) Z F X 010, 012, 014, 016, 018, 021, Pressure Vessel Diameter (in inches) . . . . . . . . . . 024, 030, 036 Pressure Vessel Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F = non-code, fiberglass Control Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X = Std NEMA 3R equivalent Level of Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z = Stand alone A = 1.0" Backwash/Regeneration Initiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F = Timeclock NEMA 3R (equivalent) B = 1.5" Inlet/Outlet Pipe Size† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C = 2.0" X X = No Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Options To determine your catalog order number, replace the X with one of the numbered options below it. These filters are also available as duplex units. Please contact our Technical Support team for more information. †All sizes not available with every tank size. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 158 MULTIMEDIA FILTERS VP Series Multimedia Filters Flow Rates from 25 to 420 gpm VP Series Multimedia Filters are a low cost, reliable and efficient way to purify water. These rugged, pre-engineered, pre-assembled units minimize installation and startup costs and are ideal for boiler feed, process water or rinse water applications. • VPEF denotes non-ASME code vessels offered with express delivery • VPAF denotes ASME code vessels with stamp available • Simple design maximizes reliability and efficiency • 100 psig vessel rating offers added strength and integrity • Structural steel legs (seismic zone 4) provide rigid support of vessel for safety • Skid mount (seismic zone 4) with structural steel beams for duplex systems • Backwash and regeneration controls are highly reliable • Optional metallic piping ensures long life and durability • Standard epoxy internal and external coating extends vessel life • Schedule 80 PVC piping enhances corrosion-resistance SYSTEM SPECIFICATIONS Model Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Good. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Better. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Best. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Backwash Flow Rate. . . . . . . . . . . . . . . . . . . . . . . . Media (cubic feet)* . . . . . . . . . . . . . . . . . . . . . . . . . . System Dimensions** Pipe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Column Size (D x H) . . . . . . . . . . . . . . . . . . . . . . . . inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . **H x W x D Simplex (Duplex) – inch . . . . . . . . . . **H x W x D Simplex (Duplex) –cm . . . . . . . . . . . Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . lb. – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . kg – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . Operating Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . lb. – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . kg – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . Electrical Requirements. . . . . . . . . . . . . . . . . . . . . . Model Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Good. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Better. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Best. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Backwash Flow Rate. . . . . . . . . . . . . . . . . . . . . . . . Media (cubic feet)* . . . . . . . . . . . . . . . . . . . . . . . . . . System Dimensions** Pipe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Column Size (D x H) . . . . . . . . . . . . . . . . . . . . . . . . inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H x W x D Simplex (Duplex) – inch . . . . . . . . . . . H x W x D Simplex (Duplex) –cm . . . . . . . . . . . . . Shipping Weight lb. (kg). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . kg – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . Operating Weight lb. – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . kg – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . Electrical Requirements. . . . . . . . . . . . . . . . . . . . VPEF/VPAF-024 VPEF/VPAF-630 VPEF/VPAF-636 VPEF/VPAF-742 1-1/2” 2” 2-1/2” 2-1/2” 1,530 (3,060) 694 (1,388) 2,240 (4,480) 1,017 (2,033) 50 40 25 47 7.8 70 60 40 74 13.3 24x48 61x122 76x42x41 (80x97x41) 193x107x104 (204x246x104) 30x60 77x153 90x42x48 (94x97x48) 229x107x123 (239x246x122) 105 85 55 106 17.7 140 115 75 144 24.0 36x60 92x153 96x40x55 (97x97x57) 244x102x140 (247x246x145) 3,410 (6,820) 1,547 (3,094) 42 x 72 107x183 112x43x60 (116x133x60) 285x109x152 (295x338x152) 4,820 (9,640) 2,186 (4,372) 2,330 (4,660) 3,500 (7,000) 5,600 (11,200) 7,800 (15,600) 1,057 (2,114) 1,588 (3,176) 2,541 (5,081) 3,538 (7,076) 110 V / 60 Hz / 1 ph / 3 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VPEF/VPAF-648 VPEF/VPAF-754 VPEF/VPAF-760 VPEF/VPAF-772 185 150 100 188 31.4 235 190 125 239 39.8 290 230 150 295 49.1 48x60 122x153 106x58x67 (106x133x67) 269x147x170 (269x338x170) 54x72 139x183 121x61x75 (123x158x75) 307x155x191 (312x401x191) 60x72 153x183 125x68x88 (127x158x88) 318x173x224 (323x401x224) 3” 6,200 (12,400) 2,813 (5,625) 3” 8,300 (16,600) 3,765 (7,530) 4” 10,435 (20,870) 4,733 (9,466) 420 335 225 424 70.6 4” 72x72 183x183 125x68x88 (131x158x100) 318x173x224 (333x401x254) 14,980 (29,960) 6,795 (13,590) 10,160 (20,320) 13,320 (26,640) 16,765 (33,530) 24,110 (48,220) 4,609 (9,217) 6,042 (12,084) 7,604 (15,208) 10,936 (21,872) 110 V / 60 Hz / 1 ph / 3 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . *Filtration media includes 18" of Anthracite (0.85-0.95 mm), 8" of Filter Sand (0.45-0.55 mm) and 4" of Garnet (0.3 mm). **Approximate ORDERING INFORMATION VP Series Multimedia Filters have extensive option packages. For ordering instructions, or additional product information, please contact technical support at 800.875.7873 extension 5000. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Section Table of Contents 159 PUMPS, CENTRIFUGAL Multiple Stage Centrifugal Booster Pumps Victaulic® Type Pumps Vertical, multi-stage centrifugal pumps are designed with the motor mounted directly on top of the pump housing to minimize footprint. Pump suction/discharge chamber, impellers, pump shaft, diffuser chambers, outer discharge sleeve, and impeller seal ring retainers are constructed of 316 stainless steel. The motor stool is constructed of cast iron and is isolated from the process fluid by a 316 stainless steel insert. Each pump is equipped with a high temperature mechanical seal assembly. Pumps are capable of operating at continuous temperatures up to 250°F (121°C). The pump motor is sized to ensure non-overloading when operating on the pump curve. Motors are totally enclosed fan cooled (TEFC), with NEMA C face designs that provide a minimum service factor of 1.15. Lower motor bearings are adequately sized to ensure long motor life. SPECIFICATIONS – please contact Technical Support to obtain pump curves MODEL NUMBER CRN3-3 CRN3-4 CRN3-5 CRN3-7 CRN3-8 CRN3-10 MODEL NUMBER Catalog Number . . . . . . . . . . . . . . . . . Nominal Flow Rate (gpm) . . . . . . . . . . Pump Efficiency . . . . . . . . . . . . . . . . . Max Discharge Head (psi) . . . . . . . . . Max Oper Pressure (psi) . . . . . . . . . . Min Continuous Flow (gpm) . . . . . . . . Nameplate Horsepower . . . . . . . . . . . Motor Type/Service Factor . . . . . . . . . Shipping Weight (lb) . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . GPC96083742 GPC96083744 GPC96083746 GPC96083750 GPC96083752 GPC96083756 15 @ 35 psi 15 @ 39 psi 15 @ 52 psi 15 @ 71 psi 15 @ 95 psi 15 @ 104 psi 58% 58% 58% 58% 58% 58% 41 54 69 95 108 136 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 1.5 1.5 1.5 1.5 1.5 1.5 0.5 HP 0.75 HP 0.75 HP 1.5 HP 1.5 HP 2.0 HP TEFC TEFC TEFC TEFC TEFC TEFC 50.5 48.4 48.9 63.5 66.3 73 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/4-inch Victaulic type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number . . . . . . . . . . . . . . . . . Nominal Flow Rate (gpm) . . . . . . . . . . Pump Efficiency . . . . . . . . . . . . . . . . . Max Discharge Head (psi) . . . . . . . . . Max Oper Pressure (psi) . . . . . . . . . . Min Continuous Flow (gpm) . . . . . . . . Nameplate Horsepower . . . . . . . . . . . Motor Type/Service Factor . . . . . . . . . Shipping Weight (lb) . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . GPC96084823 GPC96084827 GPC96084829 GPC96084831 GPC96084833 GPC96084837 30 @ 28 psi 30 @ 52 psi 30 @ 63 psi 30 @ 74 psi 30 @ 82 psi 30 @ 106 psi 65% 65% 65% 65% 65% 65% 41 69 84 97 113 141 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 3 3 3 3 3 3 1 HP 1.5 HP 2 HP 3 HP 3 HP 3 HP TEFC TEFC TEFC TEFC TEFC TEFC 50.5 65.9 71.9 91.2 92.8 94.6 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/4-inch Victaulic type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Rated Flow (gpm) Pump Efficiency Max Discharge Head (psi) Max Oper Pressure (psi) Min Continuous Flow (gpm) Nameplate Horsepower Motor Type/Service Factor Shipping Weight (lb) Electrical Requirements . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . Inlet/Outlet Victaulic Style. . . . . . . . . . GPC96523104 GPC96523105 GPC96523106 GPC96523255 GPC96523707 GPC96523708 GPC96523710 53 @ 31 psi 53 @ 49 psi 53 @ 65 psi 53 @ 83 psi 90 @ 66 psi 90 @ 89 psi 90 @ 130 psi 70% 70% 70% 70% 70% 70% 70% 40 65 85 105 85 105 170 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 5.5 5.5 5.5 5.5 8.5 8.5 8.5 1.5 HP 3 HP 3 HP 5 HP 5 HP 7.5 HP 10 HP TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 101 139 141 164 159 184 223 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-inch Victaulic type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MODEL NUMBER ORDERING INFORMATION Victaulic Sets Victaulic Connector Set Available Victaulic Connector Set Available CRN5-3 CRN5-5 CRN5-6 CRN5-7 CRN5-8 CRN5-10 CRN10-2 CRN10-3 CRN10-4 CRN10-5 CRN15-3 CRN15-4 Size 1-1/4" 2" CRN15-7 GPC96523711 90 @ 156 psi 70% 195 360 psi 8.5 15 HP TEFC/1.15 278 Catalog No. P90348 P90349 High Capacity Pumps available. Call Technical Support. BACK CRN15-6 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 160 PUMPS, CENTRIFUGAL Multiple Stage Centrifugal Booster Pumps ANSI Flange Vertical, multi-stage centrifugal pumps are designed with the motor mounted directly on top of the pump housing to minimize footprint. Pump suction/discharge chamber, impellers, pump shaft, diffuser chambers, outer discharge sleeve, and impeller seal ring retainers are constructed of 316 stainless steel. The motor stool and flanges are constructed of cast iron and are isolated from the process fluid by 316 stainless steel inserts. Each pump is equipped with a high temperature mechanical seal assembly. Pumps are capable of operating at continuous temperatures up to 250°F (121°C). The pump motor is sized to ensure non-overloading when operating on the pump curve. Motors are totally enclosed fan cooled (TEFC), with NEMA C face designs that provide a minimum service factor of 1.15. Lower motor bearings are adequately sized to ensure long motor life. MODEL NUMBER CRN3-3 CRN3-4 CRN3-5 CRN3-7 CRN3-8 CRN3-10 CRN5-3 CRN5-5 CRN5-6 CRN5-7 CRN5-8 CRN5-10 CRN10-2 CRN10-3 CRN10-4 CRN10-5 CRN15-3 CRN15-4 Catalog Number . . . . . . . . . . . . . . . . . Nominal Flow Rate (gpm) . . . . . . . . . . Pump Efficiency . . . . . . . . . . . . . . . . . Max Discharge Head (psi) . . . . . . . . . Max Oper Pressure (psi) . . . . . . . . . . Min Continuous Flow (gpm) . . . . . . . . Nameplate Horsepower . . . . . . . . . . . Motor Type/Service Factor . . . . . . . . . Shipping Weight (lb) . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . GPC96083922 GPC96083924 GPC96083926 GPC96083930 GPC96083932 GPC96083936 15 @ 35 psi 15 @ 39 psi 15 @ 52 psi 15 @ 71 psi 15 @ 95 psi 15 @ 104 psi 58% 58% 58% 58% 58% 58% 41 54 69 95 108 136 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 1.5 1.5 1.5 1.5 1.5 1.5 0.5 HP 0.75 HP 0.75 HP 1.5 HP 1.5 HP 2.0 HP TEFC TEFC TEFC TEFC TEFC TEFC 58.4 56.3 56.9 72.5 75.4 80.9 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/4-inch ANSI Flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number . . . . . . . . . . . . . . . . . Nominal Flow Rate (gpm) . . . . . . . . . . Pump Efficiency . . . . . . . . . . . . . . . . . Max Discharge Head (psi) . . . . . . . . . Max Oper Pressure (psi) . . . . . . . . . . Min Continuous Flow (gpm) . . . . . . . . Nameplate Horsepower . . . . . . . . . . . Motor Type/Service Factor . . . . . . . . . Shipping Weight (lb) . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . GPC96085013 GPC96085017 GPC96085019 GPC96085021 GPC96085023 GPC96085027 30 @ 28 psi 30 @ 52 psi 30 @ 63 psi 30 @ 74 psi 30 @ 82 psi 30 @ 106 psi 65% 65% 65% 65% 65% 65% 41 69 84 97 113 141 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 3 3 3 3 3 3 1 HP 1.5 HP 2 HP 3 HP 3 HP 3 HP TEFC TEFC TEFC TEFC TEFC TEFC 58.4 74.9 79.8 99.1 100.7 102.5 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/4-inch ANSI Flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Rated Flow (gpm) Pump Efficiency Max Discharge Head (psi) Max Oper Pressure (psi) Min Continuous Flow (gpm) Nameplate Horsepower Motor Type/Service Factor Shipping Weight (lb) Electrical Requirements . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . GPC96523118 GPC96523119 GPC96523120 GPC96523265 GPC96523718 GPC96523719 GPC96523721 53 @ 31 psi 53 @ 49 psi 53 @ 65 psi 53 @ 83 psi 90 @ 66 psi 90 @ 89 psi 90 @ 130 psi 70% 70% 70% 70% 70% 70% 70% 40 65 85 105 85 105 170 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 5.5 5.5 5.5 5.5 8.5 8.5 8.5 1.5 HP 3 HP 3 HP 5 HP 5 HP 7.5 HP 10 HP TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 110 150 152 175 170 194 234 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel with cast iron flange and base plate* and mechanical silicon carbide seal faces . . . . . . . . . . 2-inch ANSI Flange type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MODEL NUMBER MODEL NUMBER CRN15-6 *Cast iron flange and base plate does not come in contact with pumped liquid. High Capacity Pumps available. Call Technical Support. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents CRN15-7 GPC96523722 90 @ 156 psi 70% 195 360 psi 8.5 10 HP TEFC/1.15 370 161 PUMPS, FEEDWATER BOOSTER Feedwater Booster Pumps Siemens feedwater booster pumps are close-coupled, single stage, end suction design capable of being serviced without disturbing piping connections. The pump casings are self venting, with a center line discharge design, and are fabricated of 304 stainless steel casing seal ring. The enclosed-type impeller is constructed of 304 stainless steel. It is dynamically balanced, keyed to the steel shaft and secured by a 304 stainless steel capscrew. The liquid cavity is sealed off at the pump shaft by an internally flushed mechanical seal with stainless steel metal parts, Buna-N elastomers and carbon to ceramic faces, suitable for continuous operation at 225°F. A replaceable, aluminum-bronze, shaftsleeve completely covers the wetted area under the seal. Pumps are rated for 125 psi (175 psi for Series 3531 Pumps) working pressure. All casings have a drain tapping. Pump motors meet NEMA specifications, are totally enclosed fan cooled (TEFC), have heavy-duty grease-lubricated ball bearings, and are sized to be non-overloading over the entire pump range. SPECIFICATIONS* 3530 Series/MODEL NUMBER Catalog Number . . . . . . . . . . . . . . . . . Design Capacity (gpm). . . . . . . . . . . . Pump Efficiency . . . . . . . . . . . . . . . . . Motor Horsepower . . . . . . . . . . . . . . . Motor Type/Service Factor . . . . . . . . . Electrical Requirements . . . . . . . . . . . Power at Full Load (KW) . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . Inlet. . . . . . . . . . . . . . . . . . . . . . . . . . . Outlet . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions (WxLxH) inches . . . . . . . Shipping Weight (lb) . . . . . . . . . . . . . . 3531 Series/MODEL NUMBER Catalog Number . . . . . . . . . . . . . . . . . Design Capacity (gpm). . . . . . . . . . . . Pump Efficiency . . . . . . . . . . . . . . . . . Motor Horsepower . . . . . . . . . . . . . . . Motor Type/Service Factor . . . . . . . . . Electrical Requirements . . . . . . . . . . . Power at Full Load (KW) . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . Inlet. . . . . . . . . . . . . . . . . . . . . . . . . . . Outlet . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions (WxLxH) inches . . . . Shipping Weight (lb) . . . . . . . . . . . . . . 3530-30-2 3530-30-3 3530-30-9 1.25x1.5x5 1.5x2x5 2x2.5x5 3530 3530-30-2 3530-30-3 3530-30-9 PF1CB6NA4 PF1DB6NG4 PF1ED6NC4 PF3AB6NA4 PF3CB6NA4 PF3DB6NG4 PF3ED6NC4 27 @ 25 psid 35 @ 35 psid 76 @ 25 psid 5 @ 25 psid 27 @ 25 psid 35 @ 35 psid 76 @ 25 psid 52% 53% 61% 40% 52% 53% 61% 1.0 HP 1.5 HP 2.0 HP 0.5 HP 1.0 HP 1.5 HP 2.0 HP TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 115/230V 115/230V 230/460V 230/460V 230/460V 230/460V 230/460V 16/8A; 1ph 20/20A; 1ph 12A; 3ph 24/12A; 3ph 3.6/1.8A; 3ph 5.2/2.6A; 3ph 6.8/3.4A; 3ph 0.83 1.2 1.6 1.6 0.83 1.2 1.6 Horizontal, closed-coupled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 stainless steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11⁄4" NPTF 11⁄4" NPTF 11⁄2" NPTF 11⁄2" NPTF 11⁄4" NPTF 11⁄4" NPTF 11⁄2" NPTF 1" NPTF 1" NPTF 11⁄4" NPTF 11⁄4" NPTF 1" NPTF 1" NPTF 11⁄4" NPTF 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9 41 45 45 37 41 45 45 PF3GD5NE4 PF3HE5NE4 PF3IF5FC4 135 @ 35 psid 200 @ 30 psid 290 @ 35 psid 61% 59% 68% 5.0 HP 7.5 HP 10.0 HP TEFC/1.15 TEFC/1.15 TEFC/1.15 230/460V 230/460V 230/460V 15.2/7.6A; 3 ph 22/11A; 3 ph 28/14A; 3 ph 3.5 5.1 6.4 Horizontal, closed-coupled . . . . . . . . . . . . . 304 stainless steel . . . . . . . . . . . . . . . . . . . . 11⁄2" NPTF 2" NPTF 21⁄2" 150# flange 11⁄4" NPTF 11⁄2" NPTF 2" 150# flange 12x23x11 15x24x12 15x25x12 101 130 175 *Please contact Technical Support to obtain pump curves Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 162 REVERSE OSMOSIS MEMBRANES Replacement Reverse Osmosis (RO) Membranes Siemens is your leading source for replacement membranes. We supply elements from all of the major manufacturers. For your convenience, we inventory FILMTEC™ and Hydranautics® membranes at our regional distribution facilities. This enables us to meet short lead times and thereby minimize your system downtime. In addition, we also stock major components such as replacement gauges, pumps and end caps. Whether it involves normal wear-and-tear replacement, maintenance or spares inventory, Siemens has the products to support your membrane system. Manufacturer Size DxL Ionpure Ionpure Ionpure Ionpure Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Filmtec Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics 4 x 40 4 x 40 8 x 40 8 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 Siemens Catalog No. 06/PL32364-01R 06/PL32364-02R 06/PL32364-04R 06/PL32364-06R ROSTW4040 CDRCLP4040 CDRCXLE4040 CDRC4X40B CDRCLE4X40B CDRC4X40L CDRCF4040L379P CDRCSW304040 CDRC30365 CDRC8X40D CDRC8X40LE CDRC30365FR CDRCBW30400/34I CDRCBW30440I CDRCLE440I CDRCSW30XLE400I CDRCSW30HRLE400I CDRCSW30HRLE400 ROLSA4040 CDHYESPA14040 CDHYESPA24040 CDHYESPA34040 CDHYESPA44040 CDHYSWC14040 ROLSY8040 CDHYCPA3 CDHYCPA4 CDHYESPA1 CDHYESPA2 CDHYESPA3 CDHYESPA4 CDHYSWC3 CDHYSWC3PLUS CDHYSWC4PLUS CDHYSWC5 Manufacturer’s Catalog No. PWS PFC-4 PWS HS2-4 PWS PFC-8 PWS HS2-8 TW30-4040 LP-4040 XLE-4040 BW30-4040 BW30LE-4040 RO-4040-FF HSRO-4040-FF SW30-4040 BW30-365 BW30-400 BW30LE-440 BW30-365FR BW30-400/34i BW30-440i LE-440i SW30-400i SW30HR-LE400i SW30HR-LE400 CPA2-4040 ESPA1-4040 ESPA2-4040 ESPA3-4040 ESPA4-4040 SWC1-4040 CPA2 CPA3 CPA4 ESPA1 ESPA2 ESPA3 ESPA4 SWC3 SWC3+ SWC4 SWC5 Type Approx GPD % Reject TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC TFC 2300 2800 9000 11200 2400 3200 2600 2400 2300 2650 1900 1500 9500 10500 11500 9500 10500 11500 12650 9000 7500 7500 2250 2600 1900 3000 2500 1100 10000 11000 6000 12000 9000 15000 12000 5900 7000 6500 9000 99.6 99.6 99.6 99.6 99.5 99.2 99.0 99.5 99.2 99.5 99.5 99.2 99.5 99.5 99.2 99.5 99.5 99.5 99.3 99.7 99.8 99.8 99.2 99.0 98.0 98.0 99.2 99.6 99.2 99.6 99.7 99.0 99.5 98.0 99.2 99.6 99.8 99.8 99.8 Items in BLUE are stocked by Siemens. For availability of other items, please contact your local Siemens sales representative. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents REVERSE OSMOSIS MEMBRANES - OBSOLETE SIEMENS SYSTEMS CARO RO Membrane Cartridges • Spiral wound modules constructed of cellulose acetate membrane • Designed to operate in Series 60, 120, 250, 350, M-1000/2000/3000 RO systems, and other units • Chlorine tolerant for sanitization • Good salt rejection • Competitive flux rates • Ideal for medical, hemodialysis, pharmaceutical, biotechnology, food and beverage and laboratory applications PERFORMANCE AND PHYSICAL SPECIFICATIONS Initial Flow Rate @ 25°C/200 psi Initial Rejection Monovalent Ions Initial Rejection Divalent Ions . . Length/in. (cm) . . . . . . . . . . . . . Diameter/in. (cm) . . . . . . . . . . . Diameter (unstressed chevron seal)/in. (cm) . . . . . . . . Membrane Surface Area (ft2) (m2). . . . . . . . . . . . . . . . . . . . . Product Tube Diameter/in. (cm). . MR40 1.0 L/min >90% >95% 25 (63.5) 3.5 (8.9) MR60 > 1.3 L/min >93% >96% 25 (63.5) 3.84 (9.75) 3.74 (9.50) 4.21 (10.69) — 40 (3.72) — 60 (5.57) — FEED WATER SPECIFICATIONS Operating Pressure. . . 140-400 psi <–0.5 ppm Temperature . . . . . . . . 2-35°C pH . . . . . . . . . . . . . . . . 4 - 7.5 Silt Density Index . . . . < 5 ORDERING INFORMATION RO System MR40C Cartridges Series 60 . . . . . . . . . . . . . . . . . Series 120 . . . . . . . . . . . . . . . . Series 250 . . . . . . . . . . . . . . . . Series 350 . . . . . . . . . . . . . . . . MR60 Cartridges Series 1000, 2000 . . . . . . . . . . 4x40/8x40 Cartridges Series 2500, 3000 . . . . . . . . . . Series 4000, 8400 . . . . . . . . . . 4 x 40 1360 gpd >96% 8 x 40 7000 gpd >96% 40 (101.6) 40 (101.6) 4 (10.2) 8 (20.3) — 0.625 (1.59) 1.5 (3.81) Langelier Saturation Index of Reject Free Chlorine. . . . . . . . . . . . . . . . . <1.5 ppm Maximum Cartridge Recovery. . . . 15% Maximum Feed Turbidity. . . . . . . . 1 NTU Cartridges Used Quantity Required CDRO 025 S1 CDRO 025 S1 CDRO 025 SH CDRO 025 S1 CDRO 025 SH CDRO 025 S1 CDRO 025 SH 1 each 1 each 1 each 1 each 2 each 1 each 3 each CDRO M60 S1 Quantities vary, consult Technical Support CDROFG440 (1/pk) CDROFG840 (1/pk) Quantities vary, consult Technical Support Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 163 164 REVERSE OSMOSIS SYSTEMS VANTAGE™ MicRO Flow Rates from 0.1 to 1.6 gpm Vantage™ MicRO Series reverse osmosis units are designed and manufactured for commercial applications. Each MicRO model consists of a single stage, positive displacement, rotary vane pump, and tap water membranes. Each unit is fully tested at the factory and only requires simple utility connections (feed water inlet, product water outlet, drain and a power source). Capabilities • High pressure feed pump • PVC end entry pressure vessels • Spiral wound thin film composite (TFC) membranes • Hand/Off/Auto switch for system operation • Schedule 80 PVC product piping • Electrical cord with male plug designed to be plugged into a standard 115VAC, grounded receptacle SYSTEM SPECIFICATIONS Model Number MCRO1 MCRO2 MCRO4 MCRO8 MCRO12 MCRO16 Product Flow* (gpm)................................ Feed Flow (gpm)...................................... Reject Flow (gpm).................................... Reject Recycle (gpm) .............................. 0.1 0.2 0.1 0.6 0.17 0.34 0.17 0.6 0.4 0.8 0.4 0.8 0.8 1.6 0.8 1.6 1.2 2.4 1.2 2.5 1.6 3.2 1.6 3.2 Feed Inlet................................................. Product Outlet.......................................... Reject to Drain Outlet .............................. 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT Membrane Size........................................ Membranes/Vessel .................................. Membrane Quantity ................................. 2.5” diameter 1 1 2.5” diameter 1 1 2.5” diameter 1 1 2.5” diameter 1 2 2.5” diameter 1 3 2.5” diameter 1 4 Vessel Staging ......................................... 1 1 1 1:1 1:1:1 1:1:1:1 H x W x D . . . . . . . . . . . . .inches Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . .lb 48x28x10 48x28x10 48x28x10 48x28x10 48x28x10 48x28x10 47 50 53 57 61 65 High Voltage Service ............................... High Voltage FLA..................................... 120V 1PH 6.5 120V 1PH 6.5 120V 1PH 6.5 120V 1PH 6.5 120V 1PH 6.5 120V 1PH 6.5 Connections Membranes Vessels System Dimensions** Electrical Requirements *Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters. **Does not include operating space requirements. OPTIONAL ACCESSORIES Catalog No. MCRIP04 MCRIP16 MCRTL MCRSP Description Prefilter gauge, feed water low-pressure switch, product flow meter, reject recycle flow meter for: MCRO1, MCRO2, MCRO4 Prefilter gauge, feed water low-pressure switch, product flow meter, reject recycle flow meter for: MCRO8, MCRO12, MCRO16 Tank level switch for all models Free standing mounting frame for all models In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 165 REVERSE OSMOSIS SYSTEMS VANTAGE™ M21 Series RO Flow Rates from 0.4 to 1.6 gpm Vantage™ Reverse Osmosis units are pre-engineered systems specifically designed for a variety of industrial applications. Vantage™ systems offer you the greatest flexibility possible from a standard system. The control system is an advanced microprocessorbased system that is very easy to use. Capabilities • TFC (thin film composite) RO membranes ensure optimum water quality • Microprocessor-based controller provides user-friendly programmable controls • Small footprint minimizes required space • Low energy membranes reduce operating costs • Clean-in-place connections maximize system availability • Dial-up capability enables real-time remote monitoring (optional) SYSTEM SPECIFICATIONS Model Number Product Flow* (gpm) . . . . . . . . . . Feed Flow (gpm) . . . . . . . . . . . . . Reject Flow (gpm) . . . . . . . . . . . . Reject Recycle (gpm) . . . . . . . . . Connections Feed Inlet . . . . . . . . . . . . . . . . . . . Product Outlet . . . . . . . . . . . . . . . Reject to Drain Outlet . . . . . . . . . Membranes Membrane Quantity . . . . . . . . . . . Membrane Size . . . . . . . .(inches) Vessels Vessel Array . . . . . . . . . . . . . . . . . System Dimensions** HxWxD inches . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . Shipping Weight lb . . . . . . . . . . . . . . . . . . . . . . . kg . . . . . . . . . . . . . . . . . . . . . . M21R001 M21R002 M21R003 M21R004 0.4 0.8 0.4 3.1 0.8 1.6 0.8 2.3 1.2 2.4 1.2 1.5 1.6 3.2 1.6 0.7 1 2.5x40 2 2.5x40 3 2.5x40 4 2.5x40 62x17x26 157x43x66 62x17x26 157x43x66 3/4” NPT 1/2” tube 3/8” tube 1 62x17x26 157x43x66 80 36 3/4” NPT 1/2” tube 3/8” tube 1:1 62x17x26 157x43x66 90 41 3/4” NPT 1/2” tube 3/8” tube 1:1:1 100 45 3/4” NPT 1/2” tube 3/8” tube 1:1:1:1 110 50 *Product flow rates are based on equipment design parameters and may not be appropriate for other feed waters. **Does not include operating space requirements. ORDERING INFORMATION Catalog Number: M21R . . . . . . . . . . . . . . . M21R Vantage M21 Series RO 004 E 001 - 1 Membrane 002 - 2 Membranes 003 - 3 Membranes Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 004 - 4 Membranes Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - Economy Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D A - 120/240 VAC, 1 PH, 60 HZ B - 208 VAC, 3 PH, 60 HZ C - 230 VAC, 3 PH, 60 HZ D - 460 VAC, 3 PH, 60 HZ E - 575 VAC, 3 PH, 60 HZ F - 380 VAC, 3 PH, 50 HZ In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 166 REVERSE OSMOSIS SYSTEMS VANTAGE™ M41 High Purity (HP) Series RO Flow Rates from 1.4 to 15 gpm The Vantage™ M41RHP (High Purity) series RO units are designed and manufactured for industrial applications. Units contain 4-inch membranes with flow rates of 1.4 to 15.0 gallons 3 per minute (0.32 to 3.4 m /hr). They arrive with membranes installed and only require simple utility connections to begin operations. Their simple designs maximize reliability of the RO unit. Capabilities • TFC membranes (choice of full-fit or brackish water) ensure optimum water quality • Microprocessor-based controller provides user-friendly programmable controls • Clean-in-place connections maximize system availability and serviceability • Optional modem is available to enable real-time remote monitoring • Stainless steel high pressure piping and fittings • Reject recycle maximizes water recovery and minimizes waste SYSTEM SPECIFICATIONS Model Number* M41RHP001 Product Flow** (gpm) Feed Flow (gpm) Reject Flow (gpm) Reject Recycle (gpm) 1.4 2.8 1.4 7.0 Connections Feed Inlet Product Outlet Reject to Drain Outlet M41RHP002 M41RHP003 6.2 8.3 2.1 6.0 7.0 9.3 2.3 6.0 4 x 40 2 4 x 40 3 4 x 40 4 4 x 40 5 4 x 40 6 1:1:1:1 1:1:1:1:1 2:1:1:1:1 Vessel Staging 1 1:1 1:1:1 Model Number* M41RHP008 M41RHP009 M41RHP012 4 x 40 1 Vessels System Dimensions*** Shipping Weight . . . . . . . . . . . . . . . . . . . lb Product Flow** (gpm) Feed Flow (gpm) Reject Flow (gpm) Reject Recycle (gpm) Connections Feed Inlet Product Outlet Reject to Drain Outlet Membrane Size Membrane Quantity Vessels System Dimensions*** Shipping Weight . . . . . . . . . . . . . . . . . . . lb 575 1-1/2" Flange 3/4" NPT 3/4" NPT 600 10.0 13.3 3.3 8.0 12.0 16.0 4.0 11.0 15.0 20.0 5.0 10.0 4 x 40 8 4 x 40 9 4 x 40 12 3:2:2:1:1 3:3:2:2:1:1 1-1/2" Flange 3/4" NPT 3/4" NPT Membranes Vessel Staging 550 2:2:1:1:1:1 750 M41RHP006 5.2 6.9 1.7 6.0 1-1/2" Flange 3/4" NPT 3/4" NPT Membrae Size Membrane Quantity M41RHP005 4.0 8.0 4.0 4.0 1-1/2" Flange 3/4" NPT 3/4" NPT Membranes M41RHP004 2.8 5.6 2.8 5.0 1-1/2" Flange 3/4" NPT 3/4" NPT 775 1-1/2" Flange 3/4" NPT 3/4" NPT 625 1-1/2" Flange 3/4" NPT 3/4" NPT 650 1-1/2" Flange 3/4" NPT 3/4" NPT 675 1-1/2" Flange 3/4" NPT 3/4" NPT 850 *The 4 designates 4" housing, the 1 designates element in length, and the 0X designates the number of membranes. **Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters. ***Does not include operating space requirements. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 167 REVERSE OSMOSIS SYSTEMS VANTAGE™ M41 High Purity (HP) Series RO Flow Rates from 1.4 to 15 gpm ORDERING INFORMATION Catalog Number: M41RHP . . . . . . . . . . . . . M41RHP Vantage M41 High Purity RO 012 E 001 - 1 Membrane 002 - 2 Membranes 003 - 3 Membranes 004 - 4 Membranes 005 - 5 Membranes 006 - 6 Membranes 008 - 8 Membranes 009 - 9 Membranes Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 012 - 12 Membranes Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - Economy Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S D S - BW30-4040 F - RO-4040-FF B - 208 VAC, 3 ph, 60 Hz C - 230 VAC, 3 ph, 60 Hz D - 460 VAC, 3 ph, 60 Hz E - 575 VAC, 3 ph, 60 Hz Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F - 380 VAC, 3 ph, 50 Hz In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 168 REVERSE OSMOSIS SYSTEMS VANTAGE™ M41 General Purpose (GP) Series RO Flow Rates from 1.4 to 10 gpm Vantage™ Reverse Osmosis units are pre-engineered systems specifically designed for a variety of industrial applications. Vantage™ systems offer the greatest flexibility possible from a standard system. The control system is an advanced microprocessorbased system that is very easy to use. Capabilities • TFC (thin film composite) RO membranes ensure optimum water quality • Low energy membranes reduce operating costs • Reject recycle maximizes water recovery and minimizes waste • Clean-in-place connections maximize system availability • Dial-up capability enables real-time remote monitoring (optional) SYSTEM SPECIFICATIONS Model Number with centrifugal pump . . . . Product Flow* (gpm) . . . . . . Feed Flow (gpm) . . . . . . . . . Reject Flow (gpm) . . . . . . . . Reject Recycle (gpm) . . . . . Connections Feed Inlet. . . . . . . . . . . . . . . Product Outlet . . . . . . . . . . . Reject to Drain Outlet . . . . . Membranes Membrane Quantity . . . . . . . Membrane Size. . . . (inches) Vessels Vessel Array. . . . . . . . . . . . . System Dimensions** HxWxD . . . . . . . . . . . . . . . . . inches . . . . . . . . . . . . . . . . . . . . cm Shipping Weight . . . . . . . . . . . . . . . . . . . . . lb . . . . . . . . . . . . . . . . . . . . . kg M41RGP001 1.4 2.8 1.4 6.8 M41RGP002 2.8 5.6 2.8 4.0 M41RGP003 4.0 8.0 4.0 9.3 M41RGP004 5.2 8.0 2.8 9.0 M41RGP005 6.3 8.3 2.0 9.0 M41RGP006 7.5 10.0 2.5 7.3 M41RGP008 10 13.3 3.3 4.0 1-1/2”NPT 3⁄4” NPT 3⁄4” NPT 1-1/2”NPT 3⁄4” NPT 3⁄4” NPT 1-1/2”NPT 3⁄4” NPT 3⁄4” NPT 1-1/2”NPT 3⁄4” NPT 3⁄4” NPT 1-1/2”NPT 3⁄4” NPT 3⁄4” NPT 1-1/2”NPT 3⁄4” NPT 3⁄4” NPT 1-1/2”NPT 3⁄4” NPT 3⁄4” NPT 1 4x40 2 4x40 3 4x40 4 4x40 5 4x40 6 4x40 8 4x40 1 1:1 1:1:1 1:1:1:1 1:1:1:1:1 2:1:1:1:1 2:2:1:1:1:1 72x38x34 183x97x86 72x38x34 183x97x86 72x38x34 183x97x86 72x38x34 183x97x86 72x38x34 183x97x86 72x38x34 183x97x86 72x38x34 183x97x86 550 250 575 261 600 273 625 284 700 318 725 330 750 341 *Product flow rates are based on equipment design parameters and may not be appropriate for other feed waters. **Does not include operating space requirements. ORDERING INFORMATION Catalog Number: M41RGP . . . . . . . . . . . . . M41RGP Vantage M41 General Purpose RO 008 001 - 1 Membrane E S D 002 - 2 Membranes 003 - 3 Membranes 004 - 4 Membranes 005 - 5 Membranes Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 006 - 6 Membranes 008 - 8 Membranes Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B -208 VAC, 3 ph, 60 Hz E - Economy Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C -230 VAC, 3 ph, 60 Hz S - XLE-4040 Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Siemens Water Technologies 24-hr Customer Service: 800.466.7873 D -460 VAC, 3 ph, 60 Hz E - 575 VAC, 3 ph, 60 Hz F - 380 VAC, 3 ph, 50 Hz In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Section Table of Contents REVERSE OSMOSIS SYSTEMS 169 VANTAGE™ M43 Series RO Flow Rates from 10.5 to 23 gpm Vantage™ Reverse Osmosis units are pre-engineered systems specifically designed for a variety of industrial applications. Vantage™ systems offer you the greatest flexibility possible from a standard system. The control system is an advanced microprocessorbased system that is very easy to use. Capabilities • TFC (thin film composites) RO membranes ensure optimum water quality • Microprocessor-based controller provides user-friendly programmable controls • Pre-engineered systems allow easy installation • Clean-in-place connections maximize system availability • Auxiliary equipment interface provides system-wide control SYSTEM SPECIFICATIONS Model Number M43R009 M43R012 M43R015 M43R018 Feed Flow (gpm) . . . . . . . . . . . . . . . . . . . . Reject Flow (gpm) . . . . . . . . . . . . . . . . . . . 16.2 5.7 21.4 6.4 25.3 6.3 30.7 7.7 Feed Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . 2” 2” 2” 2” Product Flow* (gpm) . . . . . . . . . . . . . . . . . Connections Product Outlet . . . . . . . . . . . . . . . . . . . . . . Reject to Drain Outlet . . . . . . . . . . . . . . . . Membranes Membrane Quantity . . . . . . . . . . . . . . . . . . 10.5 15 19 23 1-1/2” 1-1/2” 1-1/2” 1-1/2” 9 12 15 18 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT Membrane Size . . . . . . . . . . . . . . .(inches) 4x40 4x40 4x40 4x40 Vessel Array . . . . . . . . . . . . . . . . . . . . . . . . 1:1:1 2:1:1 2:2:1 3:2:1 Pump Type . . . . . . . . . . . . . . . . . . . . . . . . . Vertical Multi-stage Vertical Multi-stage Vertical Multi-stage Vertical Multi-stage HxWxD inches . . . . . . . . . . . . . . . . . . . . . . . . . . 63x23x129 63x23x129 63x23x129 63x23x129 Vessels Pump System Dimensions** cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shipping Weight lb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160x58x328 160x58x328 1110 160x58x328 1250 505 1400 568 160x58x328 1550 636 705 *Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters. **Does not include operating space requirements. ORDERING INFORMATION Catalog Number: M43R . . . . . . . . . . . . . . . . M43R Vantage M43 Series RO Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 018 009 - 9 Membrane E S 012 - 12 Membranes 015 - 15 Membranes 018 - 18 Membranes Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 208 VAC, 3 ph, 60 Hz E - Economy Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C - 230 VAC, 3 ph, 60 Hz S - BW30LE-4040 Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK D D - 460 VAC, 3 ph, 60 Hz E - 575 VAC, 3 ph, 60 Hz F - 380 VAC, 3 ph, 50 Hz Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 170 REVERSE OSMOSIS SYSTEMS Vantage™ M83 Series RO Flow Rates from 30 to 100 gpm Vantage™ M83 Series packaged single-pass 8-inch reverse osmosis units are designed for industrial applications requiring high quality equipment with a fast delivery and a competitive price. Standard Features: • RO Prefilter • ASME Code Vessels with Pressure Relief • Three models: Economy, Plus, and Deluxe: • Economy utilizes rotameters and a microprocessor • Plus provides more flexibility via control with a Siemens PLC and a user friendly touch screen HMI. • Deluxe provides Siemens PLC/HMI, Variable Frequency Drive and controlled feed pump, “On-Board” integrated cleaning system, loose ship chemical tank and hoses, pH/ORP measurement. Benefits: • Four (4) week standard lead time keeps your project moving. • Compact footprint saves valuable floor space. • Dry contacts are provided for chemical feed, pretreatment equipment, storage tank levels, and pressure switches. • With simple utility connections and easy to set up controls, the unit is ready for quick on-line service. GENERAL SYSTEM SPECIFICATIONS General Electrical: General Control Specs: UL, cUL Enclosures NEMA 12 or better Economy – Controlled by Microprocessor Plus – Controlled by Siemens PLC and user friendly touch screen Human Machine Interface (HMI) Deluxe (M83D) – M83P controls plus Variable Frequency Drive (VFD), pH/ORP monitor Overall Dimensions*: 168” Length, 32” Wide, 77” Height (100 gpm Unit 89” Height) Key Materials of Construction: Painted carbon steel frame, PVC low pressure piping, stainless steel high pressure piping Membrane Type: Thin Film Composite brackish water and low energy membranes (optional) Available Options: Seismic Zone 4 Anchorage Wet Stamp (CA); pH, ORP, or both on Economy and Plus Models Contact a Siemens representative for detailed specifications. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 171 REVERSE OSMOSIS SYSTEMS Vantage™ M83 Series RO Flow Rates from 30 to 100 gpm SYSTEM SPECIFICATIONS Model Number** M83R006 M83R009 M83R012 M83R015 M83R018 Feed Inlet................................................. Product Outlet.......................................... Reject to Drain Outlet .............................. 2" 1.5" 1.5" 2" 1.5" 1.5" 2" 2" 1.5" 3" 2" 1.5" 3" 3" 1.5" Membranes/Vessel .................................. Membrane Quantity ................................. 3 6 3 9 3 12 3 15 3 18 Vessel Staging ......................................... 1:1 1:1:1 2:1:1 2:2:1 3:2:1 Shipping Weight . . . . . . . . . . . .lb 2,900 3,175 3,450 3,725 4,000 Product Flow* (gpm)................................ Feed Flow (gpm)...................................... Reject Flow (gpm).................................... Reject Recycle (gpm) .............................. Connections Membranes Vessels System Dimensions 30 40 10 10 45 60 15 5 60 80 20 5 75 100 25 3 100 133 33 3 *Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters. **The 8 designates 8" housing, the 3 designates 3 elements in length, and the XXX designates the nominal design product flow rate at 65˚ (18.3˚C). ORDERING INFORMATION Catalog Number: M83R . . . . . . . . . . . . . . . . M83R Vantage M83 Series RO 018 006 - 6 Membranes E S Y D 009 - 9 Membranes 012 - 12 Membranes Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 015 - 15 Membranes E - Economy 018 - 18 Membranes P - Plus Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D - Deluxe Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S - Standard (ILEC) Element C - Cold Water (LE) Element Product Divert Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y - Divert Kit Included X - Divert Kit Not Included Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D - 460 VAC, 3 ph, 60 Hz E - 575 VAC, 3 ph, 60 Hz In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 172 REVERSE OSMOSIS SYSTEMS Vantage™ M84 Series RO Flow Rates from 100 to 214 gpm Vantage™ M84 Series packaged single-pass 8-inch reverse osmosis units are designed for industrial applications requiring high quality equipment with a fast delivery and a competitive price. Standard Features: • RO Prefilter • ASME Code Vessels with Pressure Relief • Product Divert Kit with ASME Code Pressure Relief Valve (Loose Shipped) • Three models: Economy, Plus, and Deluxe: • Economy utilizes rotameters and a microprocessor • Plus provides more flexibility via control with a Siemens PLC and a user friendly touch screen HMI. • Deluxe provides Siemens PLC/HMI, Variable Frequency Drive and controlled feed pump, “On-Board” integrated cleaning system, loose ship chemical tank and hoses, pH/ORP measurement. Benefits: • Four (4) week standard lead time keeps your project moving. • Compact footprint saves valuable floor space. • Dry contacts are provided for chemical feed, pretreatment equipment, storage tank levels, and pressure switches. • With simple utility connections and easy to set up controls, the unit is ready for quick on-line service. GENERAL SYSTEM SPECIFICATIONS General Electrical: General Control Specs: Overall Dimensions*: Key Materials of Construction: Membrane Type: Available Options: UL, cUL Enclosures NEMA 12 or better Economy – Controlled by Microprocessor Plus – Controlled by Siemens PLC and user friendly touch screen Human Machine Interface (HMI), Ethernet Deluxe –Plus controls with Variable Frequency Drive (VFD), pH and ORP monitors, Ethernet 230” Length, 54” Wide, 90” Height (maximum dimensions) Painted carbon steel frame, PVC low pressure piping, stainless steel high pressure piping Thin Film Composite brackish water and low energy membranes (optional) Seismic Zone 4 Anchorage Wet Stamp (CA); pH, ORP, or both on Economy and Plus Models Contact a Siemens representative for detailed specifications. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 173 REVERSE OSMOSIS SYSTEMS Vantage™ M84 Series RO Flow Rates from 100 to 214 gpm SYSTEM SPECIFICATIONS Model Number** M84R024 M84R036 M84R048 Feed Inlet................................................. Product Outlet.......................................... Reject to Drain Outlet .............................. 3" 3" 2" 4" 3" 2" 4" 4" 2" Membrane Size........................................ Membranes/Vessel .................................. Membrane Quantity ................................. 8 x 40 4 24 8 x 40 4 36 8 x 40 4 48 Vessel Staging ......................................... 3:2:1 4:3:2 6:4:2 Shipping Weight . . . . . . . . . . . .lb 4,550 5,400 6,000 Product Flow* (gpm)................................ Feed Flow (gpm)...................................... Reject Flow (gpm).................................... Connections Membranes Vessels System Dimensions 107 143 36 160 215 53 214 285 71 *Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters. **The 8 designates 8" housing, the 4 designates 4 elements in length, and the XXX designates the nominal design product flow rate at 65˚F (18.3˚C). ORDERING INFORMATION Catalog Number: M84R . . . . . . . . . . . . . . . . M84R Vantage M84 Series RO Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 048 E 036 - 36 Membranes E - Economy 024 - 24 Membranes 048 - 48 Membranes Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P - Plus D - Deluxe Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S D S - Standard (ILEC) Element C - Cold Water (LE) Element Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D - 460 VAC, 3 ph, 60 Hz E - 575 VAC, 3 ph, 60 Hz In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 174 NANOFILTRATION SYSTEMS Vantage™ M84 Series Nanofiltration Flow Rates from 100 to 214 gpm Vantage™ M84 Series packaged single-pass 8-inch nanofiltration units are designed for industrial and municipal applications requiring high quality equipment with a fast delivery and a competitive price. Standard Features: • Prefilter • ASME Code Vessels with Pressure Relief • Three models: Economy, Plus, and Deluxe: • Economy utilizes rotameters and a microprocessor • Plus provides more flexibility via control with a Siemens PLC and a user friendly touch screen HMI. • Deluxe provides Siemens PLC/HMI, Variable Frequency Drive and controlled feed pump, “On-Board” integrated cleaning system, loose ship chemical tank and hoses, pH/ORP measurement. Benefits: • Four (4) week standard lead time keeps your project moving. • Compact footprint saves valuable floor space. • Dry contacts are provided for chemical feed, pretreatment equipment, storage tank levels, and pressure switches. • With simple utility connections and easy to set up controls, the unit is ready for quick on-line service. GENERAL SYSTEM SPECIFICATIONS General Electrical: General Control Specs: Overall Dimensions*: Key Materials of Construction: Membrane Type: Available Options: UL, cUL Enclosures NEMA 12 or better Economy – Controlled by Microprocessor Plus – Controlled by Siemens PLC and user friendly touch screen Human Machine Interface (HMI), Ethernet Deluxe plus controls plus Variable Frequency Drive (VFD), pH and ORP monitors, Ethernet 230” Length, 54” Wide, 90” Height (maximum dimensions) Painted carbon steel frame, PVC low pressure piping, stainless steel high pressure piping Thin Film Composite nanofiltration membranes Seismic Zone 4 Anchorage Wet Stamp (CA); pH, ORP, or both on Economy and Plus Models Contact a Siemens representative for detailed specifications. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 175 NANOFILTRATION SYSTEMS Vantage™ M84 Series Nanofiltration Flow Rates from 100 to 214 gpm SYSTEM SPECIFICATIONS Model Number** M84N024 M84N036 M84N048 Feed Inlet................................................. Product Outlet.......................................... Reject to Drain Outlet .............................. 3" 3" 2" 4" 3" 2" 4" 4" 2" Membrane Size........................................ Membranes/Vessel .................................. Membrane Quantity ................................. 8 x 40 4 24 8 x 40 4 36 8 x 40 4 48 Vessel Staging ......................................... 3:2:1 4:3:2 6:4:2 Shipping Weight . . . . . . . . . . . .lb 4,300 5,150 5,650 Product Flow* (gpm)................................ Feed Flow (gpm)...................................... Reject Flow (gpm).................................... Connections Membranes Vessels System Dimensions 100 133 33 150 200 50 200 267 67 *Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters. **The 8 designates 8" housing, the 4 designates 4 elements in length, and the XXX designates the nominal design product flow rate at 65˚F (18.3˚C). ORDERING INFORMATION Catalog Number: M84N . . . . . . . . . . . . . . . . M84N Vantage M84 Series Nanofilter Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 048 E 036 - 36 Membranes E - Economy 024 - 24 Membranes 048 - 48 Membranes S D S - Standard (NF) Element D - 460 VAC, 3 ph, 60 Hz P - Plus Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D - Deluxe Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - 575 VAC, 3 ph, 60 Hz In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 176 REVERSE OSMOSIS SYSTEMS Pharm40 Series RO Systems Flow Rates from 6 to 24 gpm Pharm40 Series Reverse Osmosis (RO) Systems were designed for pharmaceutical, biotech and cosmetic applications. These systems can remove from 97 to 99% of salts1. Units are pre-assembled, pre-wired and hydrostatically tested at the factory. Control systems are comprised of a control panel and skid-mounted wiring. • System is mounted on a polyurethane coated structural steel frame • Product piping is sanitary stainless steel or sanitary polypropylene • Pump discharge piping is constructed of Schedule 10 butt welded 316L stainless steel • Product samples valves are located on the outlet of each vessel for quick and easy control • Easy, continuous control through PLC • Inputs and outputs are installed to communicate with pretreatment/post-treatment equipment • Capable of full cleaning and chemical sanitizing for advanced microbial control • Comprehensive controls and documentation facilitate easy, thorough validation requirements 1 Based on the RO performance projection. SYSTEM SPECIFICATIONS* Model Number Polypropylene*** 67/P43PP-06S/D* 67/P43PP-09S* 67/P43PP-12S* 67/P44PP-16S* 67/P44PP-20S* 67/P44PP-24S* Model Number Stainless Steel*** 67/P43SS-06S* 67/P43SS-09S* 67/P43SS-12S* 67/P44SS-16S* 67/P44SS-20S* System Dimensions HxWxD inches . . . . . . . . . . . . . . . . . . . cm. . . . . . . . . . . . . . . . . . . . . . Shipping Weight lb (kg) . . . . . . . . 72x30x140 103x76x356 1,300 (590) 72x30x140 103x76x356 1,400 (636) 72x30x140 103x76x356 1,500 (681) 72x30x182 103x76x462 1,600 (726) 72x30x182 103x76x462 1,700 (772) 72x30x182 103x76x462 1,800 (817) 480 VAC 120 VAC 480 VAC 120 VAC 480 VAC 120 VAC 480 VAC 120 VAC 480 VAC 120 VAC 480 VAC 120 VAC 4x40 6 4x40 9 4x40 12 4x40 16 4x40 20 4x40 24 Initial Production Capacity . . . . . . Maximum Recovery . . . . . . . . . . . Vessel Array. . . . . . . . . . . . . . . . . Electrical Requirements Motor Service. . . . . . . . . . . . . . . . Controls Service. . . . . . . . . . . . . . Membranes** Size . . . . . . . . . . . . . . . . . (inches) Quantity . . . . . . . . . . . . . . . . . . . . 6 gpm 75% 1:1 9 gpm 75% 1:1:1 *S - Denotes RO system equipped with Fixed I/O PLC. *D - Denotes RO system equipped with Expandable I/O PLC. 12 gpm 75% 2:1:1 16 gpm 75% 2:1:1 20 gpm 75% 2:2:1 67/P44SS-24S* 24 gpm 75% 3:2:1 *Capacities are based on a feed water stream of well or softened water. RO projections should be run to calculate actual system performance. **RO membranes are included with each system. ***Sanitary product piping. ORDERING INFORMATION Pharm40 Series RO Systems have extensive option packages. For additional product or ordering information, please contact Technical Support at 800.875.7873 ext. 5000. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 177 REVERSE OSMOSIS SYSTEMS 40 Series Reverse Osmosis Systems Flow Rates from 1.8 to 32 gpm 40 Series Reverse Osmosis (RO) Systems produce from 1.8 to 32.0 gpm of high-purity water. These systems can remove up to 98% of dissolved inorganics, over 95% of total dissolved organics and all colloidal and suspended matter larger than 0.05 micron. The flexible design accommodates virtually all TFC (thin film composite) 4” spiral wound RO membranes to suit your application. • Pre-filtration cartridges are included to protect membranes • Stainless steel pumps and piping resist corrosion • Sample valves on the feed provide an easy way to test water quality and guarantee system performance • UL Listed enclosure ensures quality and reliability • Conductivity meter and PLC controller are included SYSTEM SPECIFICATIONS Series 41 Series RO Systems Performance Specifications* Initial Production Capacity . . . . . . . . . Vessel Array . . . . . . . . . . . . . . . . . . . . 41-220 41-230 41-240 41-250 1.8 gpm 1:1 2.7 gpm 1:1:1 3.6 gpm 1:1:1:1 4x40 2 4x40 3 36x30x72 914x762x1829 500 (227) 36x30x72 914x762x1829 550 (249) Model Number Membranes† Size . . . . . . . . . . . . . . . . . . . . (inches) Quantity . . . . . . . . . . . . . . . . . . . . . . . System Dimensions HxWxD . . . . . . . . . . . . . . . . . . inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . cm Shipping Weight lb. (kg) . . . . . . . . . . . 42 Series RO Systems 42-230 42-240 43 Series RO Systems 43-230 43-240 4.5 gpm 1:1:1:1:1 5.4 gpm 1:1:1 7.3 gpm 1:1:1:1 8 gpm 1:1:1 11 gpm 2:1:1 4x40 4 4x40 5 4x40 6 4x40 8 4x40 9 4x40 12 36x30x72 914x762x1829 600 (272) 36x30x72 914x762x1829 650 (295) 36x30x96 914x762x2438 1300 (590) 36x30x96 914x762x2438 1400 (635) 138x30x82 138x30x82 3505x762x2083 3505x762x2083 1500 (681) 1600 (726) Electrical Requirements High Voltage Service . . . . . . . . . . . . . 480 VAC 3ph – 60 Hz Series (continued) 43 Series RO Systems Performance Specifications* Initial Production Capacity . . . . . . . . . Vessel Array . . . . . . . . . . . . . . . . . . . . 43-250 43-260 44 Series RO Systems 44-240 44-250 44-260 44-270 44-280 44-290 13 gpm 2:2:1 16 gpm 3:2:1 14 gpm 2:1:1 18 gpm 2:2:1 22 gpm 3:2:1 25 gpm 3:2:2 29 gpm 4:2:2 32 gpm 4:3:2 4" x 40" 15 4" x 40" 18 4" x 40" 16 4" x 40" 20 4" x 40" 24 4" x 40" 28 4" x 40" 32 4" x 40" 36 138x30x82 3505x762x2083 1700 (772) 138x30x82 3505x762x2083 1800 (817) 178x30x82 4521x762x2083 1900 (863) 178x30x82 4521x762x2083 2000 (908) 178x30x82 4521x762x2083 2100 (953) 178x30x82 4521x762x2083 2200 (999) 178x30x82 4521x762x2083 2300 (1044) 178x30x82 4521x762x2083 2400 (1090) Model Number Membranes† Size. . . . . . . . . . . . . . . . . . . . . . . . . . . Quantity . . . . . . . . . . . . . . . . . . . . . . . System Dimensions HxWxD . . . . . . . . . . . . . . . . . . inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . cm Shipping Weight lb. (kg) . . . . . . . . . . . Electrical Requirements High Voltage Service . . . . . . . . . . . . . 480 VAC 3ph – 60 Hz †Replacement RO membrane information is available. See catalog index. *Capacities are based on a feed water stream of well or softened water. RO projections should be run to calculate actual system performance. ORDERING INFORMATION Catalog Number: 67/ System Name . . . . . . . . . . 67/ ..................... ..................... Series Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ........................... ........................... XX 41 = 1M Vessel 42 = 2M Vessel 43 = 3M Vessel 44 = 4M Vessel – XXX 220 = 2 Vessels 230 = 3 Vessels 240 = 4 Vessels 250 = 5 Vessels 260 = 6 Vessels 270 = 7 Vessels – XX ........................... 280 = 8 Vessels XM = No Membranes Vessel Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 = 9 Vessels BL = Membranes shipped loose Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BN = Membranes installed In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 178 REVERSE OSMOSIS SYSTEMS Vantage™ M240 Series Two Pass Reverse Osmosis Systems Flow Rates from 5 to 20 gpm Vantage™ M240 Series Reverse Osmosis (RO) Systems can remove up to 98% of dissolved inorganics, over 95% of total dissolved organics and all colloidal and suspended matter larger than 0.05 micron. The flexible design can accommodate virtually all TFC (thin film composite) 4" spiral wound RO membranes to suit your application. • Pre-filtration cartridges are included to protect membranes • Stainless steel pumps and piping resist corrosion • Sample valves on the feed provide an easy mechanism to test water quality and guarantee system performance • UL Listed enclosure ensures quality and reliability SYSTEM SPECIFICATIONS Series M243 Series RO Systems Performance Specifications* Initial Production Capacity1 . . . . . . . . . Vessel Array . . . . . . . . . . . . . . . . . . . . . M243-250 M243-260 M244 Series RO Systems M244-260 M244-280 M244-300 5 gpm 1:1:1/1:1 7.5 gpm 2:1:1/1:1 10 gpm 2:1:1/1:1 15 gpm 2:2:1/2:1 20 gpm 3:2:1/2:1:1 4x40 9/6 4x40 12/6 4x40 16/8 4x40 20/12 4x40 24/16 Model Number Membranes† Size . . . . . . . . . . . . . . . . . . . . . (inches) Quantity (1st pass/2nd pass) . . . . . . . . System Dimensions HxWxD inches. . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . Shipping Weight lb. (kg). . . . . . . . . . . . Electrical Requirements High Volume Service . . . . . . . . . . . . . †Replacement 148x40x82 148x40x82 3579x1016x2083 3579x1016x2083 1800 (817) 1900 (863) 178x40x82 178x40x82 178x40x82 4521x1016x2083 4521x1016x2083 4521x1016x2083 2200 (999) 2400 (1090) 2600 (1180) 480 VAC 3ph – 60 Hz RO membrane information is available. See catalog index. *Capacities are based on a feed water stream of well or softened water. RO projections should be run to calculate actual system performance. 1Inlet water 20 – 75 psig operating at 75 and 90% recovery. ORDERING INFORMATION Catalog Number: 67/ XXX – XXX – System Name . . . . . . . . . . . . . 67/ 243 = Two Pass, 4", 3 Membranes/Vessel 250 = 5 Vessels Equipment Product Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 = Two Pass, 4", 4 Membranes/Vessel 260 = 6 Vessels .......................... 280 = 8 Vessels Vessel Designation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . 300 = 10 Vessels Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPTION ORDERING INFORMATION Catalog Number: XX XM = No Membranes BL = BW30-4040 shipped loose X pH Monitor = 24/S1001-161 Alarm Beacon = 24/S1001-162 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High Product Pressure Switch = 24/S1001-163 In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 179 REVERSE OSMOSIS SYSTEMS Vantage™ M280 Series Two Pass Reverse Osmosis Systems Flow Rates from 25 to 150 gpm Vantage™ M280 Series Reverse Osmosis (RO) Systems can remove up to 98% of dissolved inorganics, over 95% of total dissolved organics and all colloidal and suspended matter larger than 0.05 micron. Their flexible design can accommodate virtually all TFC (thin film composite) 8" spiral wound RO membranes to suit your application. • For manufacturing, beverage, microelectronics and boiler feed applications • Side-port membrane housing reduces maintenance costs • Pre-filtration cartridges are included to protect membranes • Stainless steel pumps and piping resist corrosion • Sample valves on the feed provide an easy mechanism to test water quality and guarantee system performance • UL Listed enclosure ensures quality and reliability SYSTEM SPECIFICATIONS Series M283 Series Performance Specifications* Initial Production Capacity Vessel Array M283-250 M284-230 25 gpm 1:1:1/1:1 Model Number Membranes† Size Quantity (1st pass/2nd pass) System Dimensions HxWxD inches cm Shipping Weight lb. (kg) Electrical Requirements High Volume Service . . . . . . . . M284 Series M284-260 M284-280 M284-290 M286-280 25 gpm 1:1/1 50 gpm 2:1:1/1:1 60 gpm 2:2:1/1:1:1 75 gpm 3:2:1/2:1 8" x 40" 9/6 8" x 40" 8/4 8" x 40" 16/8 8" x 40" 20/12 8" x 40" 24/12 166x41x78 4216x1041x1981 3000 (1361) 201x41x78 201x41x78 5105x1041x1981 5105x1041x1981 3200 (1453) 3600 (1634) M286 Series M286-310 M286-320 100 gpm 3:2/2:1 125 gpm 5:2/3:1 150 gpm 5:3/3:1 8" x 40" 30/18 8" x 40" 42/24 8" x 40" 48/24 196x56x90 196x56x90 277x56x91 277x56x91 4978x1422x2286 4978x1422x2286 7036x1422x2311 7036x1422x2311 4000 (1814) 4200 (1907) 7000 (3175) 8500 (3856) 277x56x91 7036x1422x2311 9000 (4082) 480 VAC 3ph – 60 Hz †Replacement RO membrane information is available. See catalog index. *Capacities are based on a feed water stream of well or softened water. RO projections should be run to calculate actual system performance. ORDERING INFORMATION Catalog Number: System Number . . . . . . . . 67/ XX 67/ XXX 283 = Two Pass, 8", 3 Membranes/Vessel 230 = 3 Vessels 280 = 8 Vessels 284 = Two Pass, 8", 4 Membranes/Vessel 240 = 4 Vessels 290 = 9 Vessels Equipment Series . . . . . . . . . . . . . . . . . . . . . . . 286 = Two Pass, 8", 6 Membranes/Vessel 250 = 5 Vessels 300 = 10 Vessels 260 = 6 Vessels 310 = 11 Vessels Vessel Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 = 7 Vessels 320 = 12 Vessels Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . XX XM = No Membranes BL = Membranes shipped loose OPTION ORDERING INFORMATION Catalog Number: X pH Monitor = 24/S2001-160 ....................... Product Water Flush = 24/S2001-161 ....................... Alarm Beacon = 24/S2001-162 ....................... High Pump Discharge Pressure Switch = 24/S2001-163 .......................... High Product Pressure Switch = 24/S2001-164 Options . . . . . . . . . . . . . . . . . . . . . . Interstage Caustic Injection Pump (Shipped Loose) (call tech support) In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents REVERSE OSMOSIS SYSTEMS BevMAX™ Systems For Beverage Applications Requiring 50 to 360 gpm A custom solution with standard products: BevMAX™ standard, pre-packaged reverse osmosis systems are designed for beverage, drinking water, or other applications requiring all sanitary stainless steel piping. With ten configurations available, we can create the system that meets your needs. BevMAX Systems come with the following items as standard: • 8" pressure vessels • Choice of thin film composite (TFC), with three membrane choices — standard brackish water , low-pressure, or nanofiltration • Stainless steel multi-stage booster pump • Programmable logic controller (PLC) • Butt-welded 316L stainless steel piping • Conductivity and flow monitors • Vortex shedding flow meters Although BevMAX Systems come with standard membrane, piping, pump and controller choices, you can pick and choose from a wide variety of options to configure a system that meets your specific needs. Contact your Sales Representative or our Technical Support Group for more information. l l l l l l l l l l l l Controls Type Fixed I/O PLC Nanofiltration (Low Pressure) Membrane Type Brackish Water TFC Submersible MS Horiz. Multi-Stage Pump Type Vert. Multi-Stage Sanitary 316L SST 75-300 90-360 50-250 Sanitary PPL BM Series BL Series BN Series 316L SST BevMAX . . . . . . . . . . Flow Rate Range (gpm) (at default flux rate) Product Piping PVC Unit Series Feed Piping 316L SST BevMAX™ PRE-PACKAGED UNITS AT-A-GLANCE PVC 180 l l l Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 181 REVERSE OSMOSIS SYSTEMS BevMAX™ Systems For Beverage Applications Requiring 50 to 360 gpm SYSTEM SPECIFICATIONS Model Number BL3-18 BL4-28 BL4-40 BL6-54 BL6-72 BM3-18 BM4-28 BM4-40 BM6-54 BM6-72 Membranes Membranes/Vessel . . . . . . . . . . Membrane Quantity . . . . . . . . . 3 18 4 28 4 40 6 54 6 72 3 18 4 28 4 40 6 54 6 72 3:2:1 6 4:2:1 7 5:3:2 10 6:3 9 8:4 12 3:2:1 6 4:2:1 7 5:3:2 10 6:3 9 8:4 12 Product Flow** . . . . . . . . . . . . . Feed Flow. . . . . . . . . . . . . . . . . Reject Flow. . . . . . . . . . . . . . . . Reject Recycle Flow . . . . . . . . . Nominal Recovery . . . . . . . . . . Vessels Vessel Array . . . . . . . . . . . . . . . Vessel Quantity. . . . . . . . . . . . . System Dimensions HxWxD inches . . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . . Shipping Weight lb . . . . . . . . . . . . . . . . . . . . . . kg. . . . . . . . . . . . . . . . . . . . . . 90 gpm 120 gpm 30 gpm 5 gpm 75% 140 gpm 187 gpm 47 gpm — 75% 200 gpm 267 gpm 67 gpm — 75% 270 gpm 360 gpm 90 gpm — 75% 360 gpm 480 gpm 125 gpm — 75% 75 gpm 100 gpm 25 gpm 5 gpm 75% 115 gpm 153 gpm 38 gpm — 75% 165 gpm 220 gpm 55 gpm — 75% 225 gpm 300 gpm 75 gpm — 75% 300 gpm 400 gpm 100 gpm — 75% 85x44x150 81x55x190 81x55x190 90x60x275 90x60x275 85x44x150 81x55x190 81x55x190 90x60x275 90x60x275 216x112x381 206x140x483 206x140x483 229x152x699 229x152x699 216x112x381 206x140x483 206x140x483 229x152x699 229x152x699 Electrical Requirements Controls Service . . . . . . . . . . . . Motor Service . . . . . . . . . . . . . . Motor HP . . . . . . . . . . . . . . . . . Amp Draw. . . . . . . . . . . . . . . . . 2900 1315 3800 1724 4400 1996 7500 3402 9000 4082 2900 1315 3800 1724 4400 1996 7500 3402 9000 4082 120V 480V 30 40 120V 480V 40 52 120V 480V 60 77 120V 480V 75 96 120V 480V 100 124 120V 480V 40 52 120V 480V 60 77 120V 480V 75 96 120V 480V 100 124 120V 480V 125 156 Model Number BN3-12 BN4-24 BN4-40 BN6-48 BN6-60 Product Flow** . . . . . . . . . . . . . Feed Flow. . . . . . . . . . . . . . . . . Reject Flow. . . . . . . . . . . . . . . . Reject Recycle Flow. . . . . . . . . Nominal Recovery . . . . . . . . . . Membranes Membranes/Vessel . . . . . . . . . . Membrane Quantity . . . . . . . . . Vessels Vessel Array . . . . . . . . . . . . . . . Vessel Quantity. . . . . . . . . . . . . System Dimensions HxWxD inches . . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . . Shipping Weight lb . . . . . . . . . . . . . . . . . . . . . . kg. . . . . . . . . . . . . . . . . . . . . . Electrical Requirements Controls Service . . . . . . . . . . . . Motor Service . . . . . . . . . . . . . . Motor HP . . . . . . . . . . . . . . . . . Amp Draw. . . . . . . . . . . . . . . . . 50 gpm 67 gpm 17 gpm 5 gpm 75% 100 gpm 133 gpm 33 gpm — 75% 165 gpm 220 gpm 55 gpm — 75% 200 gpm 207 gpm 67 gpm — 75% 250 gpm 333 gpm 83 gpm — 75% 3 12 4 24 4 40 6 48 6 60 2:1:1 4 4:2:1 7 5:3:2 10 5:3 8 6:4 10 85x44x150 81x55x190 81x55x190 90x60x275 90x60x275 216x112x381 206x140x483 206x140x483 229x152x699 229x152x699 4400 1996 7500 3402 7500 3402 9000 4082 9000 4082 120V 480V 10 14 120V 480V 20 27 120V 480V 25 34 120V 480V 30 40 120V 480V 40 52 **Product flow rates are based on 16-17 GFD flux rates for well water feed. These product flow rates may not be appropriate for other feed waters. An application specialist can de-rate the units for other feed water conditions. Due to different feed flow requirements and membrane type, the cartridge filter housings must be sized and ordered separately. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 182 SERVICE DEIONIZATION (SDI) Service Deionization (SDI) Systems Service Deionization (SDI) from Siemens is a convenient and economical way to produce high-purity water from potable feed water. SDI systems consist of activated carbon and ion-exchange resin contained in portable tanks, custom-designed and configured to meet your water purity requirements, flow rates and budget. With SDI systems, you don’t have to make a major capital investment, handle chemicals or maintain equipment — our technically trained service representatives handle tank delivery, installation and maintenance. Siemens offers SDI systems and resins that have been regenerated in our GMP (Good Manufacturing Practices) facility to ensure stringent quality control for critical pharmaceutical and dialysis applications. Resin, a Grade for Every Application Industrial-grade systems produce greater than 14 megohm-cm quality water, are extremely durable and can be operated at flow rates up to 150 gallons per minute or higher when multiple systems are placed in parallel. They are especially well suited for applications where large resin capacities are required. Premium-grade systems are designed for high-quality applications requiring up to 18 megohm-cm water quality. Filled with Type I or Type II resin, these systems meet CAP Type I and NCCLS Type I specifications for clinical applications. Our premiumgrade resin manufacturing process is fully batch controlled to ensure consistent quality. Ultra-grade, QSR Compliant Ultra-grade systems are designed for critical laboratory, medical, dialysis and pharmaceutical applications. These systems deliver up to 18 megohm-cm water quality with superior silica removal and significantly lower TOC levels. Our ultragrade resin manufacturing and regeneration processes are fully documented and batch controlled, in compliance with good manufacturing practices and quality system regulations. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents SERVICE DEIONIZATION (SDI) 183 Service Deionization (SDI) Systems Quality System Requirements (QSR) Mixed bed deionizers are specifically processed under QSR requirements in an FDA registered facility as a medical device for hemodialysis and ultra pure laboratory applications. These resins are controlled for not only ionic contaminant removal but also for reduced bacterial and endotoxin limitations. Each regenerated service unit is tested for pressure integrity and product water quality before it is installed in your plant. Quality Tested Before it Reaches You Quality Control Incoming QC: Raw materials must meet quality specifications. In-Process QC: Each component has its own operating criteria, and the entire process is monitored. Final Product QC: Materials are double-checked for quality with results recorded in the batch record. Disinfection Each service unit is chemically disinfected before refilling. Document Control We have a comprehensive document control system. No process changes are made without proper notification and approval. Tank Traceability The serial number of each service unit is recorded on the production control log, so total traceability is ensured. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 184 SERVICE DEIONIZATION (SDI) Service Deionization (SDI) Systems Choose from a Wide Range of Deionizers and Carbons Cation-bed Deionizers have a high capacity for removing positively charged dissolved ionic contaminants such as calcium, sodium, magnesium, potassium, iron and manganese. The durable gel resins provide stability against osmotic, thermal and impact shock. Anion-bed Deionizers have a high capacity for removing negatively charged dissolved ionic contaminants such as carbonate, bicarbonates, sulfates, chlorides, nitrates and silica. The durable gel resins used are stable against osmotic, thermal and impact shock. A variety of anion resins are available, suitable for virtually any water application. Mixed-bed Deionizers provide higher quality, and a more neutral pH than separate bed systems as well as enhanced silica and CO2 removal. Our units are guaranteed to produce the quality of water required for any removal application, up to 18 megohmcm resistivity at 25°C. In-line quality monitors immediately alert users when resin tanks need to be changed. Ultra Mixed-bed Deionizers provide superior silica removal and significantly lower TOC levels. Ideal for microelectronics and pharmaceutical applications where stricter controls of critical contaminants are required. Macroporous Organic Scavenger Resins offer extra-large internal surface areas and can therefore provide higher adsorption of dissolved and undissolved organic contaminants. The strongly basic anion resins will remove not only those organic ions normally removed by standard anion exchange, but those that would normally pass right through most demineralizers. Colloidal Scavenging Deionizers have a high capacity for removing inorganic and organic anions. The durable, macroporous resins are extremely resistant to organic fouling, and efficiently remove colloids. Activated Carbon Units remove chlorine and some dissolved organic contaminants. Each replacement carbon unit contains virgin carbon to assure maximum water quality and service life of the bed. GMP Tanks for dialysis and validated processes are also available. ORDERING INFORMATION SDI is flexible and can be customized to meet your needs. Contact Technical Support at (800) 875-7873, ext. 5000 to discuss your requirements and set-up a site visit and water analysis. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents SOFTENERS 185 KF Series Softeners Flow Rates from 3 to 275 gpm KF Series Water Softeners are lightweight, with corrosion-resistant FRP pressure vessel and cost-effective top mounted valve for commercial and light industrial applications. • Fiberglass tanks are durable and corrosion-free • Tank liners are blow-molded plastic wrapped in high-strength fiberglass and have epoxy resin for worry-free service • Softeners include a motorized, 5-cycle control valve that is quiet, efficient and dependable • Automatic regeneration controller is an electromechanical timer Requires field assembly. • Duplex systems are available for applications that require a continuous supply of softened water • Pretreatment lock-out switch assembly is included to deactivate downstream equipment during regeneration SYSTEM SPECIFICATIONS Series KFZSS Tank Size (DxH in) 9x40 12x52 14x65 16x65 18x65 21x62 24x72 30x72 36x72 42x72 48x72 Pipe Size (in) 1.0 1.0, 1.5 1.0, 1.5 1.0, 1.5 1.5, 2.0 1.5, 2.0 1.5, 2.0 2.0, 3.0 3.0 3.0 3.0 Electrical Requirements Application Commercial* RO-Feed** Service Service Flow Flow 19 gpm 39 gpm 42 gpm 46 gpm 81 gpm 77 gpm 91 gpm 105 gpm 250 gpm 268 gpm 275 gpm 3 gpm 6 gpm 9 gpm 12 gpm 15 gpm 21 gpm 30 gpm 45 gpm 60 gpm 75 gpm 120 gpm Backwash Flow 2 gpm 3.5 gpm 5 gpm 7 gpm 9 gpm 12 gpm 15 gpm 25 gpm 35 gpm 50 gpm 70 gpm Capacity at Media 15 lbs./CF Vol. (Grains in 000's) (ft3) 30 60 90 120 150 210 300 450 600 750 1200 115V/1 ph /60 Hz – 10 watts 1 2 3 4 5 7 10 15 20 25 40 Overall Shipping Dimensions Weight LxDxH (in) lb. (kg) 33x20x50 36x20x66 44x24x79 46x24x79 50x24x80 50x24x80 60x30x89 66x40x92 88x40x100 105x50x112 111x50x112 160 (73) 300 (136) 450 (204) 530 (240) 730 (331) 900 (408) 1860 (843) 1940 (880) 2460 (1116) 2880 (1306) 3660 (1660) Salt Storage lb. (kg) 350 (159) 350 (159) 700 (318) 700 (318) 700 (318) 700 (318) 1000 (454) 1000 (454) 1800 (817) 3700 (1679) 3700 (1679) *Flow is based on a differential pressure of <25 psid. Capacity is based on 10 gpg total hardness as CaCO3 that is free of color, oil and turbidity, and regeneration is at 15 lbs. NaCl/ft 3. **Maximum (RO Pretreatment) flow rate calculated at 3 gpm/ft3 ORDERING INFORMATION Catalog Number: KFZSS XXX Description . . . . . . . . . . . . . . KFZSS - Single 009, 012, 014, 016, 018, 021, 024, 030, 036, Pressure Vessel Diameter . . . . . . . . . . . . . . . . 042, 048 Pressure Vessel Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F PZV XZF X X F = Non-Code Fiberglass A = 1.0" XZF = NEMA 3R Equivalent 7-day Timelock B = 1.5" Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PZV = NEMA 3R Equivalent Volume Initiation C = 2.0" Inlet/Outlet Pipe Size† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E = 3.0" Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not all pipe sizes are available on the standard units, please use the specifications for standard sizes. X = No Option To determine your order number, replace the X with one of the numbered options below it. †All sizes are not available with every size. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 186 SOFTENERS KF Series Duplex Alternating Softeners Flow Rates from 3 to 275 gpm KF Series Duplex Alternating Water Softeners are lightweight, with corrosionresistant FRP pressure vessel, and cost-effective top-mounted valve for commercial and light industrial applications. • Fiberglass tanks are durable and corrosion-free • Tank liners are blow-molded plastic wrapped in high-strength fiberglass and units have epoxy resin for worry-free service • Softeners include two motorized, 5-cycle control valves that are quiet, efficient and dependable Requires field assembly. • Automatic regeneration controller with volume initiation facilitates operation • Maintains flow at all times. One unit is operating while second unit regenerates and is then in standby SYSTEM SPECIFICATIONS Series KFZSD Tank Size (D x H) (inch) 9 x 40 12 x 52 14 x 65 16 x 65 18 x 65 21 x 62 24 x 72 30 x 72 36 x 72 42 x 72 48 x 72 Pipe Size (in.) 1 1, 1.5 1, 1.5 1, 1.5 1.5, 2 1.5, 2 1.5, 2 2, 3 3 3 3 Application Commercial* RO-Feed** Backwash Capacity at Media Service Service Flow 15 lbs./CF Vol. Flow Flow (Grains in 000's) (ft3) 19 gpm 39 gpm 42 gpm 46 gpm 81 gpm 77 gpm 91 gpm 213 gpm 250 gpm 268 gpm 275 gpm 2 gpm 3.5 gpm 5 gpm 7 gpm 9 gpm 12 gpm 15 gpm 25 gpm 35 gpm 48 gpm 63 gpm 3 gpm 6 gpm 9 gpm 12 gpm 15 gpm 21 gpm 30 gpm 45 gpm 60 gpm 75 gpm 120 gpm 30 60 90 120 150 210 300 450 600 750 1200 Shipping Weight lb. (kg) 1 2 3 4 5 7 10 15 20 25 40 270 (123) 500 (227) 750 (341) 880 (400) 1,220 (554) 1,500 (681) 3,100 (1,407) 3,240 (1,470) 4,100 (1,860) 4,800 (2,178) 6,100 (2,767) Brine Tank Size DxH inch (cm) 18x40 (46x102) 18x40 (46x102) 24x50 (61x127) 24x50 (61x127) 24x50 (61x127) 24x50 (61x127) 24x50 (61x127) 30x48 (77x122) 39x48 (100x122) 50x60 (127x153) 50x60 (127x153) Electrical Requirements . . . . . . . . . . . . . . . . . . . 115 V/1 ph/60 Hz – 10 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . *Flow is based on a differential pressure of <25 psid. Capacity is based on 10 gpg total hardness as CaCO3 that is free of color, oil and turbidity and regeneration is at 15 lbs. NaCl/ft3. **Maximum (RO Pretreatment) flow rate calculated at 3 gpm/ft3 ORDERING INFORMATION Catalog Number: Description . . . . . . . . . . . . . . . . . . KFZSD XXX KFZSD - Duplex 009, 012, 014 016, 018, 021 Pressure Vessel Diameter . . . . . . . . . . . . . . . . . . . . . . 024, 030, 036 042, 048 F P F = Non-Code P = NEMA 3R Pressure Vessel Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fiberglass Equivalent Control Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . with electronic controls Level of Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z V X X Z = Stand Alone V = Vol. Initiated Alternating A = 1” with Totalizer B = 1.5" Backwash/Regeneration Initiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (with electronic controls) C = 2.0" Inlet/Outlet Pipe Size† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E = 3.0" Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. X = No Option To determine your catalog order number, replace the X with one of the numbered options below it. †All sizes are not available with every tank size. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Section Table of Contents 187 SOFTENERS KF Series Twin Alternating Softeners Flow Rates from 1.5 to 68 gpm KF Series Twin Alternating Water Softeners are lightweight, with corrosion-resistant FRP pressure vessel, and cost-effective top mounted valve for commercial and light industrial applications. • Fiberglass tanks are durable and corrosion-free • Tank liners are blow-molded plastic wrapped in high-strength fiberglass and units have epoxy resin for worry-free service • Softeners include a single motorized, 5-cycle control valve that is quiet, efficient and dependable • Automatic regeneration controller with volume initiation facilitates operation • Pretreatment lock-out switch assembly is included to deactivate downstream equipment during regeneration Requires field assembly. SYSTEM SPECIFICATIONS Series KFZST Tank Size (DxH in) 7x44 9x40 10x54 12x52 14x65 16x65 18x65 21x62 24x72 Pipe Size (in) 1.0 1.0 1.0 1.0, 1.5 1.0, 1.5 1.0, 1.5 1.5 1.5 1.5 Application Commercial* RO-Feed** Backwash Capacity at Service Service Flow 15 lb./CF Flow Flow (Grains in 000's) 15 gpm 19 gpm 18 gpm 39 gpm 42 gpm 46 gpm 54 gpm 52 gpm 68 gpm Electrical Requirements . . . . . . . . . . . . . 1.5 gpm 3 gpm 4.5 gpm 6 gpm 9 gpm 12 gpm 15 gpm 21 gpm 30 gpm 1.5 gpm 2 gpm 3 gpm 3.5 gpm 5 gpm 7 gpm 9 gpm 12 gpm 15 gpm 15 30 45 60 90 120 150 210 300 115 V/1 ph /60 Hz – 10 watts Media Vol. (ft3) 0.5 1 1.5 2 3 4 5 7 10 Overall Dimensions LxDxH (in) Shipping Weight lb. (kg) 33x18x53 33x20x49 34x20x63 36x20x62 44x24x75 46x24x75 50x24x75 50x24x80 60x30x88 120 (55) 190 (86) 250 (114) 310 (141) 550 (250) 700 (318) 1050 (476) 1220 (553) 1610 (730) Salt Storage lb. (kg) 350 (159) 350 (159) 350 (159) 350 (159) 700 (318) 700 (318) 700 (318) 700 (318) 1000 (454) *Flow is based on a differential pressure of <25 psid. Capacity is based on 10 gpg total hardness as CaCO3 that is free of color, oil and turbidity, and regeneration is at 15 lbs. NaCl/ft 3. **Maximum (RO Pretreatment) flow rate calculated at 3 gpm/ft3 ORDERING INFORMATION Catalog Number: KFZST Description . . . . . . . . . . . . . . . . . . KFZST - Twin ............................ Pressure Vessel Diameter . . . . . . . . . . . . . . . . . . . . . . XXX 007, 009, 010, 012, 014, 016, 018, 021, 024, F X Z N X X F = Non-Code Pressure Vessel Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fiberglass Control Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P = NEMA 3R Equivalent Level of Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z = Stand Alone N = Volume Initiated; Single Meter Backwash/Regeneration Initiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . w/Lock-Out (electromechanical) A = 1.0" Inlet/Outlet Pipe Size† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B = 1.5" X = No Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Option To determine your catalog order number, replace the X with one of the numbered options below it. †All sizes are not available with every tank size. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 188 SOFTENERS VP Series Softeners Flow Rates from 20 to 420 gpm VP Series Softeners are a low cost, reliable and efficient way to purify water. These rugged, pre-engineered, pre-assembled units minimize installation and start-up costs and are ideal for boiler feed, process water or rinse water applications. • VPES denotes Non-ASME code vessels offered with express delivery • VPAS denotes ASME code vessels with stamp available • Simple design maximizes reliability and efficiency • 100 psig vessel rating offers added strength and integrity • Structural steel legs (seismic zone 4) provide rigid support of vessel for safety • Skid mount (seismic zone 4) with structural steel beams for duplex systems • Backwash and regeneration controls are highly reliable • Optional metallic piping ensures long life and durability • Standard epoxy internal and external coating extends vessel life SYSTEM SPECIFICATIONS Model Number Flow Rates Good Better Best Backwash Flow Rate Media (cubic feet) Capacity, Kgr CaCO3 (15 lb./CF) System Dimensions* Pipe Size Column Size (D x H) inch cm Brine Tank Size - inch *H x W x D Simplex - inch (Duplex) - inch Simplex - cm (Duplex) - cm Shipping Weight lb. – Simplex (Duplex) kg – Simplex (Duplex) Operating Weight lb. – Simplex (Duplex) kg – Simplex (Duplex) Electrical Requirements VPES/VPAS-024 VPES/VPAS-030 VPES/VPAS-630 VPES/VPAS-636 VPES/VPAS-736 50 35 20 17 7 210 70 50 30 27 10 300 105 75 45 27 15 450 140 100 60 39 20 600 175 125 75 39 25 750 1-1/2” 2” 2-1/2” 2-1/2” 3” 24x48 61x122 24x48 76x41x41 (80x97x41) 193x104x104 (204x264x104) 30x48 77x122 30x60 78x43x48 (82x97x48) 198x109x122 (209x277x122) 30x60 77x153 30x60 90x51x47 (100x97x60) 229x130x119 (254x246x152) 36x60 92x153 48x48 96x51x57 (100x97x60) 244x130x145 (254x246x152) 36x72 92x183 52x60 108x55x58 (112x97x60) 274x140x147 (284x246x152) 1,100 (2,260) 499 (1,026) 1,540 (3,080) 699 (1,398) 1,890 (3,780) 858 (1,715) 2,680 (5,360) 1,216 (2,432) 3,050 (6,100) 1,384 (2,767) 1,930 (3,860) 2,740 (5,480) 876 (1,751) 1,243 (2,486) 110 V / 60 Hz / 1 ph / 3 watts 3,390 (6,780) 1,538 (3,076) 4,870 (9,740) 2,209 (4,418) 5,590 (11,180) 2,536 (5,072) *Approximate **Rating for metallic piping only. Plastic piping requires aeration due to line velocities. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents SOFTENERS 189 VP Series Softeners Flow Rates from 20 to 420 gpm SYSTEM SPECIFICATIONS Model Number VPES/VPAS-742 VPES/VPAS-748 VPES/VPAS-754 Flow Rates Good 245 280 350 Better 175 200 250 Best 105 120 150 Backwash Flow Rate 53 69 87 Media (cubic feet) 30 40 50 Capacity, Kgr CaCO3 (15 lb./CF) 900 1,200 1,500 System Dimensions* Pipe Size 3” 4” 4” Column Size (D x H) inch (cm) 42x72 (107x183) 48x72 (122x183) 54x72 (139x183) Brine Tank Size, inch 52x60 52x60 55x70 *H x W x D Simplex - inch 112x55x63 118x62x76 121x65x82 (Duplex) - inch (116x132x71) (122x133x76) (123x158x82) Simplex - cm 284x140x160 300x157x193 307x165x208 (Duplex) - cm (295x335x180) (310x338x193) (312x401x208) Shipping Weight lb.– Simplex (Duplex) 4,070 (8,140) 5,300 (10,600) 7,070 (14,140) kg – Simplex (Duplex) 1,847 (3,693) 2,405 (4,809) 3,207 (6,414) Operating Weight lb. – Simplex (Duplex) 7,590 (15,180) 9,880 (19,760) 12,980 (25,960) kg – Simplex (Duplex) 3,443 (6,886) 4,482 (8,963) 5,888 (11,776) Electrical Requirements 110 V / 60 Hz / 1 ph / 3 watts *Approximate **Rating for metallic piping only. Plastic piping requires aeration due to line velocities. VPES/VPAS-760 VPES/VPAS-772 420** 300 180 108 60 1,800 N/A 500** 300 156 100 3,000 4” 4” 60x72 (153x183) 55x70 125x70x88 (128x158x97) 318x178x224 (325x401x246) 72x72 (183x183) 69x84 129x79x100 (131x158x100) 328x201x254 (333x401x254) 8,550 (17,100) 3,879 (7,757) 13,350 (26,700) 6,056 (12,111) 15,830 (31,660) 7,181 (14,361) 24,130 (48,260) 10,946 (21,891) ORDERING INFORMATION VP Series Softeners have extensive option packages. For ordering instructions, or additional product information, please contact technical support at 800.875.7873 extension 5000. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 190 STORAGE TANKS Storage, Polyethylene, Conical-bottom, Gasket Lid w/Stand The conical bottom polyethylene storage tank (55 to 2,000 gallons) insures complete tank drainage for cleaning and sanitization operations. The tank is constructed of virgin high-density FDA approved polyethylene and supported by a structural steel stand painted with an acid resistant epoxy. • Each tank includes seven factory installed polyethylene half coupling fittings welded and tapered into the tank wall • Polyethylene tank lid with neoprene flat gasket seal is bolted to the tank for air tight access to the tank interior • 3-position level controller, hydrophobic vent filter, nitrogen blanket system and vacuum/pressure relief valve optional SYSTEM SPECIFICATIONS* Catalog Number TPCC00055 TPCC00100 TPCC00200 TPCC00250 TPCC00350 TPCC00500 TPCC00750 TPCC01000 System Dimensions Dia. (D) x Overall Height (E) (inches) Wall Thickness . . . . . . . . . . . . . . 28x64 3/16" 32x59 1/4" 35x86 1/4" 45x68 5/16" 46x88 5/16" 57x86 3/8" 68x88 3/8" 72x104 3/8" Tank Volume (gallons) . . . . . . . . Construction Materials . . . . . . . . Maximum Service Temp. . . . . . . Shipping Weight Industrial (lbs.) . . . . . . . . . . . . . . 55 100 200 250 350 500 750 1000 Virgin, high-density polyethylene that is FDA approved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rated to 160°F (70°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fittings (factory installed) Fill Fitting . . . . . . . . . . . . . . . . . . Return Fitting . . . . . . . . . . . . . . . Overflow Fitting . . . . . . . . . . . . . Outlet Fitting. . . . . . . . . . . . . . . . Vent Fitting . . . . . . . . . . . . . . . . . Level/Sight Fittings. . . . . . . . . . . 75 160 200 250 350 425 540 640 one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF two-.5" NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF two-.5" NPTF one-1.5"NPTF one-1.5"NPTF one-1.5"NPTF one-1.5"NPTF one-1"NPTF two-.5" NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF Catalog Number TPCC01500 TPCC02000 79x99 7/16" 86x103 7/16" 875 1025 one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF Tank Volume (gallons) . . . . . . . . Construction Materials . . . . . . . . Maximum Service Temp. . . . . . . System Dimensions D x H (inches) . . . . . . . . . . . . . . Wall Thickness . . . . . . . . . . . . . . Shipping Weight Industrial (lbs.) . . . . . . . . . . . . . . Fittings (factory installed) Fill Fitting . . . . . . . . . . . . . . . . . . Return Fitting . . . . . . . . . . . . . . . Overflow Fitting . . . . . . . . . . . . . Outlet Fitting. . . . . . . . . . . . . . . . Vent Fitting . . . . . . . . . . . . . . . . . Level/Sight Fittings. . . . . . . . . . . 1500 2000 Virgin, high-density polyethylene that is FDA approved Rated to 160°F (70°C) *Please contact Technical Support to obtain a drawing with exact fitting locations Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 191 STORAGE TANKS Storage, Fiberglass, Dish-bottom, Closed Top w/Skirt Constructed from premium, non-pigmented resin, which meets FDA regulations for food handling, each tank is shipped with one welded outlet siphon valve fitting, one 1/2" welded half coupling, one overflow welded half coupling and four bulkhead fittings. SYSTEM SPECIFICATIONS* Catalog Number TFDC0014A TFDC0024A TFDC0034A TFDC0045A TFDC0059A TFDC0073A TFDC0087A System Dimensions D x H (inches) . . . . . . . . . . . . . . Wall Thickness . . . . . . . . . . . . . . 30x62 5/32" 32x85 5/32" 38x85 7/32" 42x89 7/32" 48x92 7/32" 48x110 7/32" 48x129 7/32" Tank Volume (gallons) . . . . . . . . Construction Materials . . . . . . . . Shipping Weight Industrial (lbs.) . . . . . . . . . . . . . . 145 245 345 445 590 735 875 Non-pigmented premium resin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fittings Fill Fitting . . . . . . . . . . . . . . . . . . Return Fitting . . . . . . . . . . . . . . . Overflow Fitting . . . . . . . . . . . . . Outlet Fitting. . . . . . . . . . . . . . . . Vent Fitting . . . . . . . . . . . . . . . . . 74 96 154 161 211 263 285 one-1" one-1" one-1" one-1" one-1" one-1" one-1" one-1" one-1" one-1" one-1.5" one-1.5" one-1.5" one-1.5" one-1" one-1.5" one-1.5" one-1.5" one-1.5" one-1" one-2" one-2" one-2" one-2" one-1" one-2" one-2" one-2" one-2" one-1" one-2" one-2" one-2" one-2" one-1" Catalog Number TFDC0102A TFDC0151A TFDC0200A TFDC0250A System Dimensions D x H (inches) . . . . . . . . . . . . . . Wall Thickness . . . . . . . . . . . . . . 60x101 5/32" 60x143 5/32" 90x90 3/16" 72x172 7/32" 474 567 1290 820 one-2" one-2" one-2" one-2" one-1" one-2" one-2" one-2" one-2" one-1" one-2" one-2" one-2" one-2" one-1" one-2" one-2" one-2" one-3" one-1.5" Tank Volume (gallons) . . . . . . . . Construction Materials . . . . . . . . Shipping Weight Industrial (lbs.) . . . . . . . . . . . . . . Fittings Fill Fitting . . . . . . . . . . . . . . . . . . Return Fitting . . . . . . . . . . . . . . . Overflow Fitting . . . . . . . . . . . . . Outlet Fitting. . . . . . . . . . . . . . . . Vent Fitting . . . . . . . . . . . . . . . . . 1020 1515 2000 2500 Non-pigmented premium resin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . *Please contact Technical Support to obtain a drawing with exact fitting locations Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 192 STORAGE TANKS Storage, Polyethylene, Flat-bottom, Domed Top Siemens flat bottom polyethylene storage tank (55 to 6,500 gallons) has a closed cover design with a siphon valve fitting at the tank bottom for maximum drainage. The seamless one piece construction is fabricated from FDA approved virgin high density polyethylene. • Each tank includes seven factory installed polyethylene half coupling fittings welded and tapered into the tank wall • Fume tight gasketed handway or manway is mounted on the top of the closed tank to provide access to the interior • 3-position level controller, hydrophobic vent filter, nitrogen blanket system and vacuum/pressure relief valve optional SYSTEM SPECIFICATIONS* Catalog Number Tank Volume (gallons) . . . . . . . . Construction Materials . . . . . . . . Maximum Service Temp . . . . . . . System Dimensions D x H (inches) . . . . . . . . . . . . . . Wall Thickness . . . . . . . . . . . . . . Shipping Weight Industrial (lbs.) . . . . . . . . . . . . . . TPFC00055 TPFC00110 TPFC00165 TPFC00220 TPFC00300 TPFC00500 TPFC00750 TPFC01000 20x38 3/16" 35x36 3/16" 31x58 3/16" 35x63 3/16" 35x81 3/16" 46x76 1/4" 46x119 1/4" 64x81 1/4" 55 110 165 220 300 500 750 1000 Virgin, high-density polyethylene that is FDA approved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rated to 160°F (70°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fittings (factory installed) Fill Fitting . . . . . . . . . . . . . . . . . . Return Fitting . . . . . . . . . . . . . . . Overflow Fitting . . . . . . . . . . . . . Outlet Fitting. . . . . . . . . . . . . . . . Vent Fitting . . . . . . . . . . . . . . . . . Level/Sight Fittings. . . . . . . . . . . Handway . . . . . . . . . . . . . . . . . . 25 45 50 70 90 120 200 220 one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF two-.5" NPTF one-8" one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF two-.5" NPTF one-5" one-1.5"NPTF one-1.5"NPTF one-1.5"NPTF one-1.5"NPTF one-1"NPTF two-.5" NPTF one-8" one-1.5"NPTF one-1.5"NPTF one-1.5"NPTF one-1.5"NPTF one-1"NPTF two-.5" NPTF one-5" one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-16" one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-16" one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-16" one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-16" Catalog Number TPFC01500 TPFC02000 TPFC02500 TPFC03000 TPFC03600 TPFC04000 TPFC05000 TPFC06500 64x121 3/8" 64x144 3/8" 95x89 3/8" 95x105 7/8" 86x156 7/8" 95x140 1/2" 120x151 1/2" 120x144 7/8" 365 525 550 660 1050 1100 1400 1600 one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-8" one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-16" one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-1"NPTF two-.5" NPTF one-16" one-2"NPTF one-2"NPTF one-2"NPTF one-3"NPTF one-1.5"NPTF two-.5" NPTF one-16" one-2"NPTF one-2"NPTF one-2"NPTF one-3"NPTF one-1.5"NPTF two-.5" NPTF one-16" one-2"NPTF one-2"NPTF one-2"NPTF one-3"NPTF one-1.5"NPTF two-.5" NPTF one-16" one-2"NPTF one-2"NPTF one-2"NPTF one-3"NPTF one-1.5"NPTF two-.5" NPTF one-16" one-2"NPTF one-2"NPTF one-2"NPTF one-3"NPTF one-1.5"NPTF two-.5" NPTF one-16" Tank Volume (gallons) . . . . . . . . Construction Materials . . . . . . . . Maximum Service Temp . . . . . . . System Dimensions D x H (inches) . . . . . . . . . . . . . . Wall Thickness . . . . . . . . . . . . . . Shipping Weight Industrial (lbs.) . . . . . . . . . . . . . . Fittings (factory installed) Fill Fitting . . . . . . . . . . . . . . . . . . Return Fitting . . . . . . . . . . . . . . . Overflow Fitting . . . . . . . . . . . . . Outlet Fitting. . . . . . . . . . . . . . . . Vent Fitting . . . . . . . . . . . . . . . . . Level/Sight Fittings. . . . . . . . . . . Handway . . . . . . . . . . . . . . . . . . 1500 2000 2500 3000 3600 4000 5000 6500 Virgin, high-density polyethylene that is FDA approved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rated to 160°F (70°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . *Please contact Technical Support to obtain a drawing with exact fitting locations Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 193 STORAGE TANKS Terrapure®1,2 Storage Tanks Terrapure® Storage Tanks are designed for the purest process water or chemistries. They have a one-piece capsule design that provides for complete drainage. • Viton®-gasketed 6" screw lid maintains nitrogen blanket pressure • Supplied with six unique “no-profile” fittings ensure that there are no internal tank protrusions to collect particles, and no crevices, welds or seams to support microbial growth • Totally enclosed, one-piece rotationally molded construction yields a rugged, seamless, corrosion-free container suitable for an almost unlimited number of solution, storage and dispensing applications • All-plastic pedestal molded entirely of LPE (no metal reinforcement), capable of supporting loads up to 4000 lb. • Convenient “mousehole” provides easy access to the bottom center fitting • Only 34" in diameter to fit through standard doors • Can be steam cleaned (up to 190°F) and features materials that comply with FDA regulations SYSTEM SPECIFICATIONS* Catalog Number Capacity gallons. . . . . . . . . . . . . . . . Base Material . . . . . . . . . . . . . . . System Dimensions A. . . . . . . . . . . . . . . . . . . . . . . . . B. . . . . . . . . . . . . . . . . . . . . . . . . C. . . . . . . . . . . . . . . . . . . . . . . . . TPPBWF125 TPSBWF125 TPPBWF250 TPSBWF250 125 Plastic 125 Steel 250 Plastic 250 Steel 44" 61" 5/16" 44" 67" 5/16" 81" 96" 5/16" 81" 104" 5/16" Shipping Weight Tank (lbs.) . . . . . . . . . . . . . . . . . 50 50 81 Pedestal (lbs.) . . . . . . . . . . . . . . 68 100 68 *Please contact Technical Support to obtain a drawing with exact fitting locations 1 Tank must be vented to atmosphere at all times 2 Food grade construction complies with FDA regulations 1: 6" Viton® gasketed screw cap 2: Painted Carbon Steel Stand 3: Molded-in fitting flats (typical 8 places) 81 100 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 194 SYSTEM, EPV™ VALIDATABLE SKIDDED EPV™ High Purity Water Systems Flow Rates from 0.1 to 50 gpm Siemens has developed a comprehensive water system product line tailored to clients requiring validation level documentation. The Economical, Pre-Packaged, Validatable High Purity Water Systems offer a complete water system package that meets the most common quantity and quality requirements of the Laboratory, Medical, and BioPharm markets. Whatever level of water quality you require, there’s an EPV™ System to meet your needs. Designed to produce flow rates from 0.1 to 50 gallons per minute (gpm), at the point of use, these integrated, skid-mounted systems include pretreatment, make-up water, storage and distribution equipment - everything you need to ensure a reliable, cost-effective, supply of high-purity water, all with validation level documentation. Standard Features: • Developed for laboratory, biotechnology and pharmaceutical applications • Multiple configurations including: Service DI, Non-recirculating Pretreatment, Continuous Recirculating Pretreatment, and Hot Water Sanitizable • Easy installation / skid mounted • Complete documentation package including O&M with installation, start-up and operation procedures, P&ID, Electrical Schematics, Installation and Operational Qualification Verification Data Sheets, and Quality Assurance data reports • Optional documentation includes: Dry Factory Acceptance Test, Wet Factory Acceptance Test, Installation Protocol, Operational Protocol, and Performance Qualification Protocol Benefits: • Fast delivery with pre-manufactured systems • UL and Seismic Zone 4 compliance to meet regional permitting regulations • Meets or exceeds the following water quality requirements: USP Purified Water, CAP I, ASTM I, 18.2 megohm-cm resistivity • Validation Assistance available for execution of the Installation/Operational/Performance Qualifications Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 195 SYSTEM, EPV™ VALIDATABLE SKIDDED EPV™ Systems Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 196 SYSTEM, PreVUE® AND APEX™ VALIDATED SKIDDED PreVUE® and APEX™ Systems Modular USP Purified Water Generation Seven sizes—nominal flow rates range from 2 to 25 gpm. The PreVUE® and APEX™ systems are pre-engineered, totally integrated and automated biopharmaceutical water purification systems. These characteristics help you expedite all phases of planning, procuring and commissioning a new water purification system. Pre-Engineered • Prompt drawing submittals speed construction and planning • Quick delivery keeps project moving fast • cGMP design & construction assures quality Validation • Fully functional wet FAT reduces start-up time • Easily understood GAMP 4 formatted validation documentation • Protocols submitted in advance of the equipment Integrated Controls and Human Machine Interface (HMI) • User friendly large color touch screen Single-skid Design • Fast installation saves time and money • Smooth start-up • Small footprint Hot Water Sanitizable (optional on APEX™ system) • Automated for reliable sanitization without chemicals Proven Technologies • RO and CDI-LX™ Systems for reliable, efficient and continuous operation • Flexible configurations to meet your production needs Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 197 SYSTEM, PreVUE® AND APEX™ VALIDATED SKIDDED PreVUE® Systems Modular USP Purified Water Generation PERFORMANCE SPECIFICATIONS Model 20 40 60 80 130 180 250 Maximum Product, gpm (m3/hr) 2.3 (.5) 4.4 (1) 6.6 (1.5) 8.8 (2) 15.3 (3.5) 19.8 (4.5) 28.8 (6.5) Nominal Product, gpm (m3/hr) 2.0 (.45) 4.0 (.9) 6.0 (1.4) 8.0 (1.8) 13.0 (2.9) 18.0 (4.1) 25.0 (5.7) Minimum Product, gpm (m3/hr) 1.5 (.3) 1.7 (.4) 3.4 (.8) 5.4 (1.2) 7.7 (1.7) 12.6 (2.9) 17.1 (3.9) Maximum Feed, gpm (m3/hr) 3.3 (.7) 6.5 (1.5) 9.7 (2.2) 13.1 (3) 22.7 (5.1) 29.3 (6.6) 42.7 (9.7) Maximum Drain, gpm (m3/hr) 10 (2.3) 12 (2.7) 15 (3.4) 20 (4.5) 30 (6.8) 40 (9.1) 60 (13.6) Nominal Recovery, % 64 68 68 68 68 68 68 Inlet Pressure 60 to 95 psig regulated +/- 5 psig Inlet Temperature 45 to 85°F (7.2 to 35°C) Note: Flow rates and recoveries are contingent upon feedwater quality. Pressure and temperature regulation required by customer. Contact your local Siemens Water Technologies sales representative for details. PHYSICAL SPECIFICATIONS Model Height Width Depth Shipping Weight, lbs (kgs) Operating Weight, lbs (kgs) Feed Water Inlet, Flanged Product Outlet, Tri Clamp Skid Drain, Flanged Break Tank Capacity 20 3,300 (1497) 4,200 (1905) 3/4” 1/2” ELECTRICAL SPECIFICATIONS Requirements EQUIPMENT SPECIFICATIONS Softeners Activated Carbon Filter Pretreatment Filter Pretreatment UV Break Tank RO Pump RO Vessels RO Membranes CEDI Modules Frame Controls HMI OPTIONAL COMPONENTS Sodium Bisulfite Injection Hardness Monitor pH Adjust Final UV Final Filter 40 60 78” (198 cm) 120” (305 cm) 60” (152 cm) 3,800 (1724) 4,400 (1996) 4,600 (2082) 5,500 (2495) 1” 1” 3/4” 3/4” 2” 37 gallons (140 liters) 80 4,600 (2087) 6,000 (2722) 1-1/2” 3/4” 130 180 78” (198 cm) 120” (305 cm) 66” (168 cm) 6,300 (2858) 7,500 (3042) 8,400 (3810) 9,700 (4400) 1-1/2” 2” 1” 1” 3” 90 gallons (341 liters) 250 8,600 (3901) 11,900 (5398) 2” 1-1/2 ” 480V, 3Ph 60 Hz Fiberglass reinforced composite vessels with brass multiport valves (not hot water sanitizable) Stainless steel vessel, 100 psig ASME code with removable insulation jacket Stainless steel housing with 5.0 micron cartridge filter Stainless steel chamber with 254 nm lamp 316L stainless steel with bolted lid Stainless steel vertical multi-stage centrifugal with VFD Fiberglass reinforced composite vessels, ASME code Full fit thin film composite polyamide, hot water sanitizable CDI-LX,™ hot water sanitizable 304 Stainless steel PLC in NEMA 4X stainless steel enclosure 10” color touch screen Metering pump and solution tank with manual rate control, chlorine analyzer for alarm Hardness analyzer integrated into control system Metering pump, solution tank and pH monitor with automatic rate control by control system Sanitary stainless steel chamber with 254 nm lamp Sanitary stainless steel housing with 0.1 micron cartridge filter In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 198 SYSTEM, PreVUE® AND APEX™ VALIDATED SKIDDED APEX™ Systems Modular USP Purified Water Generation PERFORMANCE SPECIFICATIONS Model 20 40 60 80 130 180 250 Maximum Product, gpm (m3/hr) 2.3 (.5) 4.4 (1) 6.6 (1.5) 8.8 (2) 15.3 (3.5) 19.8 (4.5) 28.8 (6.5) Nominal Product, gpm (m3/hr) 2.0 (.45) 4.0 (.9) 6.0 (1.4) 8.0 (1.8) 13.0 (2.9) 18.0 (4.1) 25.0 (5.7) Minimum Product, gpm (m3/hr) 1.5 (.3) 1.7 (.4) 3.4 (.8) 5.4 (1.2) 7.7 (1.7) 12.6 (2.9) 17.1 (3.9) Maximum Feed, gpm (m3/hr) 3.3 (.7) 6.5 (1.5) 9.7 (2.2) 13.1 (3) 22.7 (5.1) 29.3 (6.6) 42.7 (9.7) Maximum Drain, gpm (m3/hr) 10 (2.3) 12 (2.7) 15 (3.4) 20 (4.5) 30 (6.8) 40 (9.1) 60 (13.6) Nominal Recovery, % 64 68 68 68 68 68 68 Inlet Pressure 60 to 95 psig regulated +/- 5 psig Inlet Temperature 45 to 85°F (7.2 to 35°C) Note: Flow rates and recoveries are contingent upon feedwater quality. Pressure and temperature regulation required by customer. Contact your local Siemens Water Technologies sales representative for details. PHYSICAL SPECIFICATIONS Model Height Width Depth Shipping Weight, lbs (kgs) Operating Weight, lbs (kgs) Feed Water Inlet, Flanged Product Outlet, Tri Clamp Skid Drain, Flanged Break Tank Capacity 20 40 3,300 (1497) 4,200 (1905) 3/4” 1/2” ELECTRICAL SPECIFICATIONS Requirements EQUIPMENT SPECIFICATIONS Softeners Activated Carbon Filter Pretreatment Filter Pretreatment UV Break Tank RO Pump RO Vessels RO Membranes CEDI Modules Frame Controls HMI OPTIONAL CONFIGURATIONS Sulfite Dechlorination Hot Water Sanitization (APEX only) Permeate Piping (APEX only) OPTIONAL COMPONENTS Sodium Bisulfite Injection Hardness Monitor pH Adjust Final UV Final Filter 60 78” (198 cm) 120” (305 cm) 60” (152 cm) 3,800 (1724) 4,400 (1996) 4,600 (2082) 5,500 (2495) 1” 1” 3/4” 3/4” 2” 37 gallons (140 liters) 80 4,600 (2087) 6,000 (2722) 1-1/2” 3/4” 130 180 78” (198 cm) 120” (305 cm) 66” (168 cm) 6,300 (2858) 7,500 (3042) 8,400 (3810) 9,700 (4400) 1-1/2” 2” 1” 1” 3” 90 gallons (341 liters) 250 8,600 (3901) 11,900 (5398) 2” 1-1/2 ” 480V, 3Ph 60 Hz Fiberglass reinforced composite vessels with brass multiport valves (not hot water sanitizable) Stainless steel vessel, 100 psig ASME code with removable insulation jacket Stainless steel housing with 5.0 micron cartridge filter Stainless steel chamber with 254 nm lamp FRP dished bottom Stainless steel vertical multi-stage centrifugal with VFD Fiberglass reinforced composite vessels, ASME code Full fit thin film composite polyamide, hot water sanitizable (optional) CDI-LX,™ hot water sanitizable Polyurethane painted carbon steel PLC in NEMA 4 carbon steel enclosure 10” color touch screen Metering pump and solution tank with manual rate control, chlorine analyzer for alarm HWS option includes break tank heater, heater panel, and HWS membranes Stainless steel piping (from RO/CEDI permeate) Metering pump and solution tank with manual rate control, chlorine analyzer for alarm Hardness analyzer integrated into control system Metering pump, solution tank and pH monitor with automatic rate control by control system Sanitary stainless steel chamber with 254 nm lamp Sanitary stainless steel housing with 0.1 micron cartridge filter Siemens Water Technologies 24-hr Customer Service: 800.466.7873 In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice. BACK Section Table of Contents 199 TEMPORARY MOBILE WATER TREATMENT Mobile Demineralization Flow Rates from 50 to 600 gpm For over 30 years, Siemens has met the short-term and emergency treated water needs of our customers using our mobile demineralizer (DI) trailers. These trailers are the treatment of choice for zero-discharge applications and seasonal treated water needs. A reliable and extensive service network, an ever-expanding trailer fleet and strategically located regeneration facilities allow Siemens Water Technologies to effectively serve our large North American customer base. Using mobile DI services, customers meet their treated water needs without on-site waste generation, hazardous chemical handling and capital investments. The following types of trailers allow Siemens to match our customers’ exact capacity and flow needs with the correct trailer: • MT 3000 is our three-vessel trailer with up to 3 million grain capacity and flows to 200 gpm. • MT 4500 is our four-tank trailer that includes a weak-base anion vessel. With flows of 200 gpm and capacities up to 4 million grains on certain feedwaters, this trailer is ideally suited for feedwaters with high free mineral acidity. • MT 5000 is our largest mobile DI trailer with a nominal 5 million grain capacity. This is a two-train trailer with a flow of 300 gpm per train (600 gpm total). • MT 5500 is a our six-vessel trailer with a nominal 5 million grain capacity. This trailer may be loaded in a variety of configurations to meet specific treatment needs at flow rates to 600 gpm. Generally used for short-term or emergency needs, mobile demineralizer trailers have the maximum versatility you need. These trailers are specially designed using costeffective configurations allowing specific match to your site and feedwater conditions. They provide a convenient source of water for pilot facilities, system scale-ups and commercialization product testing. They are ideal for use during start-ups, preventative maintenance and breakdowns of existing equipment. They provide large quantities of high-purity water rapidly with no on-site waste. SPECIFICATIONS Series MT 3000 Very effective for lower capacity, lower flow rate and low TDS water applications (especially for power industry) MT 4500 Very effective for low alkalinity / high FMA (free mineral acidity) applications MT 5000 Highest flow rate per trailer in the industry, completely automatic two-train system Nominal Exchange Capacity (kgr)* . . . . . . . . . . . . . . 3,000 4,500 Vessel Composition. . . . . . . . . . . . . . . . . . . . . . . . . . Carbon Steel Carbon Steel Carbon Steel Carbon Steel ASME Code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Yes Yes Yes Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vessel Lining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Tanks/Trailer Vulcanized Rubber 4 Tanks/Trailer 5,000 MT 5500 High capacity, multiple combinations for versatility of applications 6 Tanks/Trailer Vulcanized Rubber Vulcanized Rubber Flow Rate (gpm) Min. / Max.. . . . . . . . . . . . . . . . . . . 50/200 50/200 50/600 Inlet / Outlet Hose Connections . . . . . . . . . . . . . . . . 2-1/2" Minimum 2-1/2" Minimum 2-1/2" Minimum Inlet Pressure (psig) Min. / Max. . . . . . . . . . . . . . . . . Weight (lbs.) Shipping / Operating . . . . . . . . . . . . . . Dimensions – Width x Length x Height. . . . . . . . . . . Trailer Electrical Requirements . . . . . . . . . . . . . . . . . . . Heater Electrical Requirements . . . . . . . . . . . . . . . . . . . 45/100 35,000/42,000 8’ x 32’ x 13.5’ 50/100 47,000/62,000 8’ x 32’ x 13.5’ 60,000/84,500 8’ x 48’ x 13.5’ 115V, Single Phase, 60 Hz, 10 Amps ............................................ Conductivity Meters on Primary and Polish Outlet Ports ............................................ Free Chlorine <0.25 ppm Typical Water Service Quality . . . . . . . . . . . . . . . . . . . . * Based on a 1µS/cm end point. Vulcanized Rubber 40/100 2-1/2"– 4" Minimum 58,000/84,500 8.5’ x 48’ x 13.5’ (2) 115V, Single Phase, 60 Hz, 30 Amps Flow Indicator and Totalizer on Main Header Feedwater Requirements . . . . . . . . . . . . . . . . . . . . . . . . 6 Tanks/Trailer 50/400 40/100 Instrumentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................................ 5,000 Pressure Gauges and Sample Ports Turbidity <3 NTU Conductivity: 0.1 - 1.0 µS/cm and Silica Leakage: <20 ppb Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 200 TEMPORARY MOBILE WATER TREATMENT Mobile Clarification 1.5 MGD Maximum The mobile clarifier unit from Siemens Water Technologies is a self-contained trailermounted system capable of treating highly turbid water (>1000 NTU). The system is capable of producing extraordinarily clear effluent (0.5-1.0 NTU) with remarkable stability under varying raw water conditions. The Actiflo® clarification process from Kruger Inc. uses microsand as a seed to enhance floc formation and increase settling rate. The microsand promotes production of higher quality effluent than other types of clarification systems and is ideally suited for treatment of raw water that is traditionally difficult to treat, such as: high or low turbidity, high color/TOC, cold water, high algae, colloidal silica. Its stability, ease of operation and small footprint make the clarifier trailer ideal for clarifying 750 gpm of rapidly fluctuating raw water sources, in limited space and in frequent start-up/shutdown applications. The system provides clear effluent water in even the most demanding raw water conditions. Mobile systems contain instrumentation and equipment for a fully automatic and monitored operation. Chemical feed skids and fail safe shut-down controls are also included to ensure efficient and reliable operation. When using Siemens mobile systems, we guarantee quality, quantity and cost of produced water. All mobile equipment is backed with an inventory of standard critical components. Our skilled service team is on-call 24 hours per day to meet your needs. We have over 80 local service facilities across the United States to service your needs. SPECIFICATIONS Design Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................................................. Operating Weight – Dimensions (LxWxH) 48' x 8'6" x 13' 6" . Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Coagulation Tank HRT @ design . . . . . . . . . . . . . . . . . . . . . . Injection Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maturation Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Settling Tank Load Rate @ design . . . . . . . . . . . . . . . . . . . . . Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................................................. ................................................. Instrument–Influent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................................................. ................................................. ................................................. Instrument–Effluent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Panel–PLC-based . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................................................. ................................................. ................................................. ................................................. ................................................. 1 MGD, design 1.5 MGD, max 95,000 lbs. 48 feet 8 feet, 6 inches 13 feet, 6 inches 1.7 minutes 1.7 minutes 6.0 minutes 30 gpm/ft2 480V, 3ph, 100 amps 8” flange inlet 10” flange outlet 4” flange drain Raw water turbidity meter Raw water pH meter Raw water flow meter Coagulated water pH meter Clarified water turbidity meter NEMA 12 UL® label Operator interface display Signal isolators Surge protectors Circuit breakers I/O terminal strips Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 201 TEMPORARY MOBILE WATER TREATMENT Mobile Reverse Osmosis (RO) The Mobile RO unit from Siemens Water Technologies is a self-contained system that employs pretreatment and reverse osmosis (RO) capability in a single trailer. The system is capable of producing 200 gpm of low conductivity product water under a variety of raw water conditions. The versatile 200 gpm Mobile RO trailer can provide multi-media, carbon, or softening pretreatment consistent with the raw water’s impurities. The trailer can be configured as a 90 gpm double-pass unit for applications requiring extensive DI polishing. This approach can reduce DI polishing costs by as much as 80-90%. Because the RO unit combines pretreatment and RO in a single trailer, installation costs and response times are reduced significantly. This means lower produced water costs and minimum downtime for Siemens Water Technologies customers. Mobile systems contain instrumentation and equipment for fully automatic and monitored operation. Chemical feed skids and fail-safe shut-down controls are also included to ensure efficient and reliable operation. Siemens backs its mobile systems with a guarantee of quality, quantity and cost of produced water. All mobile equipment is supported by an inventory of standard critical components. A skilled service team is on-call 24 hours per day to respond to your needs. SPECIFICATIONS Dimensions (LxWxH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48’ x 8.5’ x 13.5’ Weight (Shipping/Operating) . . . . . . . . . . . . . . . . . . . . . . . . . . . 55,000 lbs. Max./70,000 lbs. Feed Water (gpm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133-506 Product Water (gpm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90-200 Drain (gpm) Concentrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-66 Backwash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80-240 Pressure (psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50-90 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480 VAC/3 ph/200 Amp Air Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 SCFM @ 80 psig Service Connections (150# PVC Flange) Inlet/Outlet/Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4”/4”/4” Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA 4X w/Allen-Bradley® SLC-5/03 PLC Remote I/O – PLC Interface Pretreatment Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 x 54" dia. (45-60 ft3) each Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Carbon, filter media (various), resin FlexRO®-100 Units Membranes (3:2:1 Array) . . . . . . . . . . . . . . . . . . . . . . . . . 24 ea (TFC or CA) Prefilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 SS, 12 round x 3 high Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 HP Multi-stage Instrumentation Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product/Concentrate Specific Conductance . . . . . . . . . . . . . . . . . . . . . . . . . . . Feed/Product pH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Feed ORP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Feed Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Various Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 202 TEMPORARY MOBILE WATER TREATMENT PreFlex® Pretreatment Units PreFlex® pretreatment units from Siemens Water Technologies are modular in design, pre-plumbed, self-contained, skid-mounted units used in our mobile business. PreFlex® units are designed to the highest engineering standards with ASME code tanks, NEMA 4X panels and pneumatically actuated solenoid valves enabling them to be used in a wide variety of applications and environments including heavy industry. Configured in parallel or series, these units can be combined with other Siemens mobile products for a fully integrated water treatment system meeting your plant’s flow and quality requirements. Units may be site or trailer installed with up to six PreFlex® 54 units per trailer. Siemens Water Technologies maintains a large inventory of PreFlex® units and other mobile assets as we continue to serve a large number of companies who depend upon Siemens’ mobile capabilities and extensive service network for their short-term, emergency, seasonal, pilot and temporary water treatment needs. PreFlex® units are also used for various stand-alone pretreatment applications including: • Media filtration • Activated carbon filtration • Softening • Dealkalization • Iron and manganese removal • TOC reduction PreFlex® units are generally used for temporary needs including: • Capacity expansions • Pilot plant water • Interim usage until a permanent system is installed • Process water quality changes • Scheduled shutdowns • Seasonal water needs • Emergency water usages • Feedwater quality changes • Existing demineralization system environmental salt discharge problems Service Flow Rate (gpm) - Min./Max. Backwash Flow (gpm). . . . . . . . . Media Volume (Ft3) . . . . . . . . . . . Exchange Capacity @ 10#/ft 3 Salt Dosage (kgr) . . . . . . . . . Operating Pressure (psi) - Min./Max. Pressure Drop (psig) . . . . . . . . . . Operating Temp. (°F), Max. . . . . Service Connections - Sch. 80 PVC Inlet / Outlet / Waste (inches). . . Weight (lbs.) - Shipping . . . . . . . . - Operating . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . Electric Requirements . . . . . . . . . Type . . . . . . . . . . . . . . . . . . . . . . . Internal Lining . . . . . . . . . . . . . . . Valves / Piping / Internals. . . . . . ........................... Air Requirements . . . . . . . . . . . . . Control Panel . . . . . . . . . . . . . . . . Gauges. . . . . . . . . . . . . . . . . . . . . Applications . . . . . . . . . . . . . . . . . PreFlex 54 ACF MMF SOFT ACF N/A N/A 20 / 100 5 - 15 105 1,500 N/A 40/160 160 45 40/120 240 45 40/240 80 60 80/380 380 120 PreFlex 84 MMF SOFT N/A 20 / 100 5 - 15 105 3,750 80/300 540 120 4/4/4 6/6/4 or 6/6/6 2,700 2,700 7,700 7,700 7,700 12,500 10,200 24,600 32,200 27,500 54" W x 73" D x 97" H 92" W x 108" D x 128" H 120 V / 1 ph / 60 Hz - 10 Amps Carbon Steel, ASME Code, 100 psi Epoxy/Polyurethane Butterfly Isolation & Solenoid Valves / Sch. 80 PVC / SS 316 Bottom & PVC Top Distribution 10 SCFM (Instantaneous) @ 80 psig NEMA 4X, Remote I/O Solenoid Panel In / Out Pressure Activated Carbon (ACF) Fe and Mn Removal Softening Multimedia (MMF) TOC Removal Dealkalization 2,700 9,100 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK 80/500 200 150 Section Table of Contents 203 TEMPORARY MOBILE WATER TREATMENT FlexTrex® Deionization Units Flow Rates to 250 gpm FlexTrex® deionization units from Siemens Water Technologies are skid-mounted ion exchange units designed to treat flows ranging from 20 to 250 gpm per unit. FlexTrex® units have quick disconnects and can be installed and brought on-line in a very short period of time using flexible hoses. Regenerated off-site, these portable units do not use hazardous chemicals, do not generate any wastewater and are ideal for polishing raw or RO permeate water. In certain instances, FlexTrex® units are an economical alternative to service deionization bottles. These ASME tanks, with their rugged design, small footprint and ability to treat high flow rates, are of tremendous advantage in many instances. With their 316 SS construction, FlexTrex® 42 units treat water up to 140°F and are ideal for short or longterm condensate polishing applications. FlexTrex® units can be configured in parallel or series and combined with other Siemens products for a fully integrated water treatment system to meet your plant’s specific flow and quality requirements. They are serviced and exchanged by Siemens’ extensive and reliable service network, which is available 24 hours a day. Our regeneration facilities and experienced service personnel ensure you receive an uninterrupted, consistent supply of treated water of the quality and quantity you require. Siemens can add controls and instrumentation to these units on an as-needed basis to meet your application needs. FlexTrex® modules are generally used for: • Polishing • Pilot plant water needs • Process water quality changes • Chlorine or chloramine removal • Scheduled shutdowns • Seasonal water needs • Emergency water usages • Feedwater quality changes • Condensate polishing • Softening • Interim usage until a permanent system is installed SPECIFICATIONS FlexTrex® 36 Vessel Size . . . . . . . . . . . . . . . . . . . . . . . Media Volume (ft3) . . . . . . . . . . . . . . . . . Service Flow Rate (gpm) Min/Max. . . . . Pressure Drop (psig) at 77°F . . . . . . . . . Resin . . . . . . . . . . . . . . . . . . . . . . . . . . . Exchange Cap. (kgr) . . . . . . . . . . . . . . . Operating Pressure (psi) Min/Max. . . . . Operating Temperature (˚F) Max. . . . . . Service Connections . . . . . . . . . . . . . . . Vessel Specifications . . . . . . . . . . . . . . . Type . . . . . . . . . . . . . . . . . . . . . . . . . Internal Lining . . . . . . . . . . . . . . . . . . Piping/Internals . . . . . . . . . . . . . . . . . . . . Weight (lbs.) Shipping/Operating . . . . . . Dimensions (WxDxH) . . . . . . . . . . . . . . . Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . Media Options: . . . . . . . . . . . . . . . . . . . . . . . 36" x 48" Side Sheet 30 20 / 100 Approx. 15 at 100 gpm SAC/SBA/MB 750/420/240 20/100 100 2" or 3" FlexTrex® 42 42" x 48" Side Sheet 42 35 / 150 Approx. 15 at 150 gpm SAC/SBA/MB 1050/588/336 20/100 140 (SS only) 3" FlexTrex® 48 48" x 60" Side Sheet 60 35 / 250 Approx. 10 at 250 gpm SAC/SBA/MB 1500/840/480 20/100 100 4" Carbon Steel 316L SS Carbon Steel Vulcanized Rubber Lined None Vulcanized Rubber Lined Sch. 80 PVC Sch. 80 PVC / 316 SS Sch. 80 PVC 2,000 / 3,400 3,500 / 4,200 5,000 / 8,000 40"x42"x78" 42"x49"x90" 50"x61"x92" Lifting Lugs & Fork Lift Ports Provided -- Units Movable By Pallet Jack Strong Acid Cation Resin (SAC) Strong Base Anion Resin (SBA) Weak Acid Cation Resin (WAC) Weak Base Anion Resin (WBA) Mixed Bed Resin (MB) Activated Carbon Super 30 36" dia. X 54" Side Sheet 30 20 / 100 Approx. 25 at 100 gpm SAC/SBA/MB 750/420/240 20/100 100 2" Carbon Steel Sprayed & Baked PVC Sch. 80 PVC 2,000 / 3,400 36"x36"x76" Organic Scavenging Media Colloidal Removal Media Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 204 TEMPORARY MOBILE WATER TREATMENT FlexRO® Reverse Osmosis Units FlexRO® reverse osmosis units from Siemens Water Technologies are skid-mounted, self-contained, 100 and 125 gpm reverse osmosis units. These units feature array skids with: • SS cartridge filter housing • TEFC high efficiency motor • Multistage high pressure pump • State-of-the-art instrumentation • NEMA 4X 480 VAC motor, starter panel with a 120 VAC step-down transformer • Separate NEMA 4X control panel with PLC With their rugged, modular design, FlexRO® units are convenient to install, connect, startup and service. These units may be site installed and operated as stand-alone units or installed inside a trailer (4 FlexRO® 100 units per trailer) and controlled by the system panel. Combined with other Siemens Water Technologies mobile assets, FlexRO® units are used to assemble fully integrated water treatment systems designed to customers’ specific treated water quality and flow needs. These units are economical even on low TDS feedwater. Operating as a pretreatment to deionizers (DI), these units significantly reduce consumption of hazardous chemicals, labor and waste; extend DI service cycles; and improve treated water quality. Units may be installed in parallel for single pass or in series for double pass applications. Both thin film composite (TFC) and cellulose acetate (CA) membranes may be used in these units. Large inventories of mobile units, coupled with an extensive service network enable us to respond quickly to our customers’ seasonal, emergency, pilot or other short-term water treatment needs. SPECIFICATIONS FlexRO 100 Units: FlexRO 100 FlexRO 125 Flow Rate @ 59°F gpm Permeate / Concentrate / Feed . . . . . . . . . . . . . 100/33/133 125/42/167 Membranes (TFC or CA*) Array / Quantity. . . . . . . . . . . . . . . . . . . . . . . . . . 3:2:1 (4M) / 24 4:2:1 (4M) / 28 Starter Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA 4X -- Includes 120 VAC step-down transformer Motor Size, HP / Amps . . . . . . . . . . . . . . . . . . . . 50/65 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460 VAC / 3 ph / 60 Hz Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA 4X with PLC Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote I/O Panel / PLC Interface Connections (Schedule 80 PVC) Feed / Permeate / Concentrate . . . . . . . . . . . . . 3" / 3" / 1.5" Flanged 4" / 3" / 1.5" Flanged Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16' L X 3' D X 6'10" H 17" L x 3'4" D x 8'1" H Weight (lbs.) Shipping / Operating. . . . . . . . . . . . . 5,200 / 6,500 5,300 / 6,800 Pressure Gauge. . . . . . . . . . . . . . . . . . . . . . . . . . . Cartridge Filter In/Out; Pump Discharge (Feed to Membrane); Interstage; Concentrate; Permeate Temperature Gauge . . . . . . . . . . . . . . . . . . . . . . . . Feed Flow Indicator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Permeate and Concentrate Conductivity Analyzer. . . . . . . . . . . . . . . . . . . . . . . Feed and Permeate Cartridge Filter Housing . . . . . . . . . . . . . . . . . . . . . SS, 12 Round x 3 High *Flows and recovery rates will be different with cellulose acetate membranes. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 205 ULTRAVIOLET STERILIZERS ZCS Series Ultraviolet Light Sterilizers UV radiation can be used as a pretreatment or polishing step to destroy bacteria and to reduce total organics. Low pressure mercury discharge lamps are used to generate the UV energy, emitted at either 254 or 185 nm. The UV energy emitted at 254 nm is used as a non-chemical method for destroying microorganisms by altering the genetic material, and rendering them unable to reproduce. The shorter, and therefore more powerful 185 nm energy is used for the effective reduction of organics, commonly referred to as TOC (total oxidizable carbon). CSL-Series Ultraviolet Lights The UV units are manufactured from 304 stainless steel. The UV light rays produced by each lamp efficiently pass through the quartz sleeves and into the surrounding liquid flowing through the UV treatment chamber. Stainless baffles are included in the treatment chamber to induce turbulence and prevent channeling, maximizing the exposure to ultraviolet radiation. SP, SL and MP-2 Series Ultraviolet Lights SPECIFICATIONS FOR ZCS SERIES 254nm ULTRAVIOLET STERILIZERS Model Number SP-1 SP-2 Catalog Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No of UV lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Max Design Flow (gpm) Clear water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RO/DI water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard Operating Press (psig)(8.3 bar) . . . . . . . . . . . Inlet/Outlet Connection. . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions (LxWxH) inch . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . Model Number Catalog Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No of UV lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Max Design Flow (gpm) Clear water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RO/DI water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard Operating Press (psig)(8.3 bar) . . . . . . . . . . . Inlet/Outlet Connection. . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions (LxWxH) inch . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . UV STERILIZERS SPARE PARTS Model Number SL-10A SL-1 MP-2-SL 2 2 120 3/8" NPTF 14x4x5 36x9x13 3 4 120 1/2"150# flange 10x6x19 26x16x48 10 12 120 1" 150# flange 14x7x38 36x17x97 20 24 120 1.5" 150# flange 38x7x21 97x18x53 ZCSL05010 4 ZCSL07810 6 ZCSL10010 8 ZCSL15610 12 40 50 120 2" 150# flange 41x11x21 104x28x53 60 78 120 2" 150# flange 41x11x21 104x28x53 80 100 120 3" 150# flange 45x12x28 104x28x53 130 156 120 3" 150# flange 45x12x28 114x33x67 SP-1 SP-2 SL-10A SL-1 CSL-4R CSL-6R CSL-8R CSL-12R ZCSL00110 1 ZCSL00210 1 1 1 120 3/8" NPTF 14x4x5 36x9x13 CSL-4R Replacement Lamp 254nm (dual ended) . . . . . . . . . . . Validated Lamp 254nm (dual ended) . . . . . . . . . . . . . . . Replacement Magnetic Ballast. . . . . . . . . . . . . . . . . . . . Replacement Quartz Sleeve (dual ended). . . . . . . . . . . ZCSPL3010 — ZCSPB3318 ZCSPQ3110 Replacement Lamp 254nm (dual ended) . . . . . . . . . . . Replacement Lamp 254 (single ended) . . . . . . . . . . . . . Validated Lamp 254nm (dual ended) . . . . . . . . . . . . . . . Validated Lamp 254nm (single ended). . . . . . . . . . . . . . Replacement Magnetic Ballast. . . . . . . . . . . . . . . . . . . . Replacement Electronic Ballast . . . . . . . . . . . . . . . . . . . Replacement Quartz Sleeve (dual ended). . . . . . . . . . . Replacement Quartz Sleeve (single ended) . . . . . . . . . ZCSPL3084 ZCSPL17491 ZCSPL16676 ZCSPL18059 ZCSPB3354 ZCSPB16518 ZCSPQ3184 ZCSPQ18347 Model Number CSL-6R ZCSPL3011 — ZCSPB3910 ZCSPQ3110 ZCSPL3084 ZCSPL17491 ZCSPL16676 ZCSPL18059 ZCSPB3354 ZCSPB16518 ZCSPQ3184 ZCSPQ18347 ZCSL00410 1 CSL-8R ZCSPL3050 ZCSPL16714 ZCSPB4035 ZCSPQ3150 ZCSPL3084 ZCSPL17491 ZCSPL16676 ZCSPL18059 ZCSPB3354 ZCSPB16518 ZCSPQ3184 ZCSPQ18347 ZCSL01210 1 CSL-12R ZCSPL3084 ZCSPL16676 ZCSPB4035 ZCSPQ3184 ZCSL02410 2 MP-2-SL ZCSPL3084 ZCSPL16676 ZCSPB3354 ZCSPQ3184 ZCSPL3084 ZCSPL17491 ZCSPL16676 ZCSPL18059 ZCSPB3354 ZCSPB16518 ZCSPQ3184 ZCSPQ18347 NOTE: Thermistors, optical sensors, sanitary connections, ozone destruction, hot temperature units, light traps, and remote electrical controls are available. Please contact Technical Support for detailed information. Mating flanges are not supplied with units. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 206 ULTRAVIOLET STERILIZERS ZHX Series The next generation of UV systems utilize a new low pressure high intensity long-life bulb that greatly increases the capacity per unit. This technology requires up to 4 times less bulbs to accommodate the same flow as original lamp designed systems. • Hot water sanitizable with UV detector to 121˚C in place • Disinfection 30,000 uW-s/cm2 • 240V/50Hz or 60Hz • 9,000 hour life at 80% intensity end of life • Temperature and UV combined in one detector package (option) • Option for NIST traceable optical detector • Option for UL Listed SPECIFICATIONS Model Number . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number . . . . . . . . . . . . . . . . . . . . . . . No of UV Lamps . . . . . . . . . . . . . . . . . . . . . . . . Max Flow (gpm) RO/DI . . . . . . . . . . . . . . . . . . Std. Oper Press (psig) . . . . . . . . . . . . . . . . . . . Inlet/Outlet Connection . . . . . . . . . . . . . . . . . . . Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . HX02BDS ZHXN04520 2 45 150 2” RF Flange 38x12x15 HX02BDL ZHXN09020 2 90 150 2” RF Flange 68x12x15 HX02DDS ZHXN11520 2 115 150 3” RF Flange 40x16x22 Model Number . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number . . . . . . . . . . . . . . . . . . . . . . . No of UV Lamps . . . . . . . . . . . . . . . . . . . . . . . . Max Flow (gpm) RO/DI . . . . . . . . . . . . . . . . . . Std. Oper Press (psig) . . . . . . . . . . . . . . . . . . . Inlet/Outlet Connection . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . HX02DDL ZHXN22020 2 220 150 3” RF Flange 68x12x24 HX04CDL ZHXN30020 4 300 120 4” RF Flange 68x10x22 HX06CDL ZHXN40520 6 405 120 4” RF Flange 68x10x22 HX02CDL ZHXN15020 2 150 120 3” RF Flange 68x10x22 SPARE PARTS HX - UV Sterilizer Spare Parts (30" for 45 and 115 gpm models,60" for all others) Description . . . . . . . . . . . . . . . . . . . . . . . . . . . 254nm Lamp 30" . . . . . . . . . . . . . . . . . . . . . . . 254nm Lamp 60" . . . . . . . . . . . . . . . . . . . . . . . 254nm Validated Lamp 30" . . . . . . . . . . . . . . . 254nm Validated Lamp 60" . . . . . . . . . . . . . . . 185nm Lamp 30" . . . . . . . . . . . . . . . . . . . . . . . 185nm Lamp 60" . . . . . . . . . . . . . . . . . . . . . . . 185nm Validated Lamp 30" . . . . . . . . . . . . . . . 185nm Validated Lamp 60" . . . . . . . . . . . . . . . 30" Quartz Sleeve . . . . . . . . . . . . . . . . . . . . . . 60" Quartz Sleeve . . . . . . . . . . . . . . . . . . . . . . Ballasts Electronic . . . . . . . . . . . . . . . . . . . . . . Compression nuts . . . . . . . . . . . . . . . . . . . . . . O-Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number ZCSPLGOLD-S ZCSPLGOLD-L ZCSPLCREAM-S ZCSPLCREAM-L ZCSPLSILVER-S ZCSPLSILVER-L ZCSPLTAN-S ZCSPLTAN-L ZCSPQ3184 ZCSPQ3198 ZCSPB416341 ZCSPM19685 ZCSPM4253 Additional higher flow models are available. Contact Technical Support. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 207 ULTRAVIOLET STERILIZERS ZCT Series SPECIFICATIONS FOR ZCT SERIES 185nm ULTRAVIOLET LIGHTS Model Number SL-1 TOC MP-2-SL TOC CSL-4R TOC CSL-6R TOC CSL-8R TOC CSL-12R TOC Catalog Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No of UV lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Max Design Flow (gpm) RO/DI water . . . . . . . . . . . . . . Design Flow Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard Operating Press (psig) . . . . . . . . . . . . . . . . . . Inlet/Outlet Connection. . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions LxWxH inch . . . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . ZCTOOO310 1 3 3 120 1" 150# flange 14x7x38 36x 18x97 ZCTOOO510 2 5 5 120 1.5"150# flange 38x7x21 97x18x53 ZCTOO1110 4 11 11 120 2" 150# flange 41x11x21 104x28x53 ZCTOO1710 6 17 17 120 2" 150# flange 41x11x21 104x28x53 ZCTOO2210 8 22 22 120 2” 150# flange 41x11x21 104x28x53 ZCTOO3510 12 35 35 120 3” 150# flange 45x13x27 114x33x69 Catalog Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No of UV lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Max Design Flow (gpm) RO/DI water . . . . . . . . . . . . . . Design Flow Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard Operating Press (psig) . . . . . . . . . . . . . . . . . . Inlet/Outlet Connection. . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions LxWxH inch . . . . . . . . . . . . . . . . . . . . . . . cm . . . . . . . . . . . . . . . . . . . . . . . . ZCTOO4510 8 45 45 120 4" 150# flange 69x13x27 175x33x69 ZCTOO5810 10 58 58 120 4" 150# flange 69x13x27 175x33x69 ZCTOO7010 12 70 70 120 4" 150# flange 69x13x27 175x33x69 ZCTOO9010 16 90 90 120 4" 150# flange 69x13x27 175x61x66 ZCTO11510 20 115 115 120 4” 150# flange 69x13x27 175x61x66 ZCTO14010 24 140 140 120 4” 150# flange 69x13x27 175x61x66 UV LIGHT SPARE PARTS Model Number SL-1 TOC MP-2-SL TOC CSL-4R TOC CSL-6R TOC CSL-8R TOC CSL-12R TOC ZCSPL16678 ZCSPL16678 Model Number Replacement Lamp 185nm (dual ended). . . . . . . . . . . . Replacement Lamp 185nm (single ended) . . . . . . . . . . Lamp 185nm (dual ended) . . . . . . . . . . . . . . . . . . . . . . . Lamp 185nm (single ended) . . . . . . . . . . . . . . . . . . . . . Replacement Magnetic Ballast. . . . . . . . . . . . . . . . . . . . Replacement Electronic Ballast . . . . . . . . . . . . . . . . . . . Replacement Quartz Sleeve (dual ended). . . . . . . . . . . Replacement Quartz Sleeve (single ended) . . . . . . . . . Model Number Replacement Lamp 185nm (dual ended). . . . . . . . . . . . Replacement Lamp 185nm (single ended) . . . . . . . . . . Lamp 185nm (dual ended) . . . . . . . . . . . . . . . . . . . . . . . Lamp 185nm (single ended) . . . . . . . . . . . . . . . . . . . . . Replacement Magnetic Ballast. . . . . . . . . . . . . . . . . . . . Replacement Quartz Sleeve (dual ended). . . . . . . . . . . Replacement Quartz Sleeve (single ended) . . . . . . . . . CSL-8R/60 TOC ZCSPL3087 CSL-10R/60 TOC CSL-12R/60 TOC CSL-16R/60 TOC CSL-20R/60 TOC CSL-24R/60 TOC ZCSPL3087 ZCSPL3087 ZCSPL18063 ZCSPL16678 ZCSPL18062 ZCSPB3354 ZCSPB16518 ZCSPQ3184 ZCSPQ18347 ZCSPL3087 ZCSPL18063 ZCSPL16678 ZCSPL18062 ZCSPB3354 ZCSPB16518 ZCSPQ3184 ZCSPQ18347 ZCSPL3087 ZCSPL18063 ZCSPL16678 ZCSPL18062 ZCSPB3354 ZCSPB16518 ZCSPQ3184 ZCSPQ18347 ZCSPL3087 ZCSPL18063Validated ZCSPL16678Validated ZCSPL18062 ZCSPB3354 ZCSPB16518 ZCSPQ3184 ZCSPQ18347 ZCSPL3095 ZCSPL17498 ZCSPL16679 ZCSPL18061 ZCSPB3354 ZCSPQ3198 ZCSPQ18348 ZCSPL3095 ZCSPL17498 ZCSPL16679 ZCSPL18061 ZCSPB3354 ZCSPQ3198 ZCSPQ18348 ZCSPL3095 ZCSPL17498 ZCSPL16679 ZCSPL18061 ZCSPB3354 ZCSPQ3198 ZCSPQ18348 ZCSPL3095 ZCSPL17498Validated ZCSPL16679Validated ZCSPL18061 ZCSPB3354 ZCSPQ3198 ZCSPQ18348 ZCSPB4035 ZCSPB3101 CSL-8R/60 TOC CSL-10R/60 TOC CSL-12R/60 TOC CSL-16R/60 TOC CSL-20R/60 TOC CSL-24R/60 TOC ZCSPQ3184 ZCSPL3095 ZCSPL17498 ZCSPL16679 ZCSPL18061 ZCSPB3354 ZCSPQ3198 ZCSPQ18348 ZCSPQ3184 ZCSPL3095 ZCSPL17498 ZCSPL16679 ZCSPL18061 ZCSPB3354 ZCSPQ3198 ZCSPQ18348 NOTE: Thermistors, optical sensors, sanitary connections, ozone destruction, hot temperature units, light traps, and remote electrical controls are available. Please contact Technical Support for detailed information. Mating flanges are not supplied with units. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 208 ULTRAVIOLET STERILIZERS Replacement UV Monitoring System Kits for Aquafine® Series UV Sterilizers Upgrade existing UV sensors with new premium UV and temperature monitoring technology. An integrated NIST traceable (optional) UV and temperature monitoring system will accurately monitor UV intensity and process water temperature of your existing UV treatment equipment from Aquafine. The new design improves reliability and performance accuracy in one state-of-the-art monitoring technology system. Component cost savings and improved liability protection will be some of the key benefits you will have with this state-of-the-art monitoring system. The detector employs a Gallium Nitride (GaN) photodiode and a semiconductor temperature sensor in a single package, along with its on-board electronics for remote and local operation features: • Detector: UV and temperature sensors in a single housing • Optional NIST-traceable UV sensor calibration with certificate upon request • No optical filters, no degradation • Withstands non-operating temperatures of 250°F • 121°C for steam sterilization at a maximum pressure of 250psi (17.2 bar) • Complete on-board electronics for UV and temperature • Absolute and percent UV readout options • Detector Cable: Water-resistant axial connector and cabling • No diffuser, therefore no UV solarization • Temperature sensor and controller does not require calibration • Detector can be used for UV Monitoring Station and Aqualogic 2000™ system. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 209 ULTRAVIOLET STERILIZERS Replacement UV Monitoring System Kits for Aquafine® Series UV Sterilizers Ordering Information for Kits. Remote UV Monitoring System This kit is intended as a remote self-contained, wall or cabinet mounted, monitoring station and detector for use with any Aquafine units. Standard Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIST Traceable Kit . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM41628 ZCSPM416281 CSL Monitoring System This kit is intended to upgrade existing CSL units with the new monitoring station and detector.* Standard Remote Integrated Kit . . . . . . . . . . . . . . ZCSPM41550 NIST Traceable Remote Integrated Kit . . . . . . . . . ZCSPM415501 *Note: Dual Chamber units require two kits Spare Parts Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIST Traceable Detector . . . . . . . . . . . . . . . . . . . . . . . . Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CPVC Compression nut . . . . . . . . . . . . . . . . . . . . . . . . . SS Compression Nut . . . . . . . . . . . . . . . . . . . . . . . . . . . O-Ring (Viton®) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM41174 ZCSPM411741 ZCSPM41116 ZCSPM4252 ZCSPM40317 ZCSPM40432 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 210 ULTRAVIOLET STERILIZERS Ultraviolet Light Traps Non-metallic piping systems that employ ultraviolet (UV) sterilization are susceptible to photochemical degradation. These piping systems must be protected from the effects of ultraviolet light emitted by the UV unit through the use of “UV Light Traps.” This line of light traps has been developed to provide that protection; traps should be installed at the inlet and outlet of the UV sterilization unit prior to connecting the unit to any nonmetallic piping material. All traps in this product line are constructed of 316L stainless steel, OD tube size, and are shipped complete with gasket (flange or sanitary) and hardware (flange bolts and/or sanitary clamp) as applicable. • Each trap is ordered separately permitting greater flexibility in selecting end connection configurations • Pre-fabricated traps ship complete with all gaskets and hardware appropriate for the end connections selected • Sizing flexibility ranges from 1/2" flange or ferrule through 4" flange or ferrule SPECIFICATIONS “S” Shaped Traps . . . . . . . . . . . SLT TTE YLT 430 “Y” Shaped Traps . . . . . . . . . . . YLT FFM - Flange x Flange - Mill Finish FFE - Flange x Flange - Electropolished FTE - Flange x Sanitary - Electropolished TTE - Sanitary x Sanitary - Electropolished TC 05 - 1/2" Flange / Ferrule (flange ring not available) 10 - 1" Flange Ring / Ferrule End Connection. . . . . . . . . . . . . . . . . . . . . . 15 - 1-1/2" Flange Ring / Ferrule 20 - 2" Flange Ring / Ferrule XX - No port for resistivity element 30 - 3" Flange Ring / Ferrule HC - 3/4" Half Coupling (threaded Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 - 4" Flange Ring / Ferrule resistivity element (FF connections only) Re Port Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TC - 1-1/2" Ferrule (sanitary resistivity element) used for 2" tube TC - 2" Ferrule (sanitary resistivity element) used for 3" and 4" tube SPECIFICATIONS SLT 20 325 - 3" Flanged UV connections, 2.5" flanged common inlet / outlet 330 - 3" Flanged UV connections, 3" flanged common inlet / outlet 430 - 4" Flanged UV connections, 3" flanged common inlet / outlet End Connection. . . . . . . . . . . . . . . . . . . . . . 440 - 4" Flanged UV connections, 4" flanged common inlet / outlet Connection Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V V - Vertical inlet / outlet H - Horizontal inlet / outlet Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 211 VALVES Blend Valves Water Temperature Blend Valves are designed to temper the inlet water to a water purification system, to optimize the water system’s performance. The valve is supplied with a temperature controller (blend valve), brass nipple and brass cross fittings, and inline dial thermometer. • Controls temperatures from 20°C to 45°C, with an optimum temperature of 25°C. Temperature setting is field-adjusted upon installation. • Thermostatic controller constructed of rough brass, chrome-plated, with an integral stop check strainer, and removable thermostatic cartridge for ease of maintenance. Control knob is constructed of stainless steel. • Wall mounting bracket is optional SYSTEM SPECIFICATIONS Catalog Number ZR2523001 Type . . . . . . . . . . . . . . . . . . . . . . Flow range . . . . . . . . . . . . . . . . . Pressure drop . . . . . . . . . . . . . . Inlet size. . . . . . . . . . . . . . . . . . . Outlet size . . . . . . . . . . . . . . . . . System Dimensions L x W x D (inches) . . . . . . . . . . . Shipping Weight lbs. . . . . . . . . . . . . . . . . . . . . . . . Optional Mounting Bracket (Catalog Number) ZR2523002 ZR2523003 ZR2523004 ZR2523005 ZR2523006 5-200-1 4–5 5–10 3/4" 3/4" 5-400-1 6–10 6–10 3/4" 1" 5-200 10–18 7–18 3/4" 3/4" 5-400 19–30 5–13 3/4" 1" 5-700 31–45 5–10 11⁄4" 11⁄2" 5-900 45–60 5–12 11⁄2" 11⁄2" 11x6x73⁄4 11x61⁄4x8 11x6x73⁄4 11x61⁄4x8 12x61⁄2x101⁄8 13x7x121⁄2 10 14 10 14 18 27 ZR2523008 ZR2523008 ZR2523008 ZR2523008 ZR2523008 ZR2523009 Pressure Relief Valves Siemens pressure relief valves are designed to prevent over pressures, maintain back pressures or act as an automatic by-pass in vessels and piping. The pressure relief valves can handle corrosive and ultra-pure liquids with inlet pressures up to 100 psi. The pressure relief valves are designed to activate at the desired set point, and contain a Teflon shaft for non-sticking operation. SYSTEM SPECIFICATIONS Catalog Number . . . . . . . . . . VALRVT050VPV ZIVC00141 Body Type . . . . . . . . . . . . . . . . . . O-ring . . . . . . . . . . . . . . . . . . . . . . Capacity . . . . . . . . . . . . . . . . . . . . Connection . . . . . . . . . . . . . . . . . Catalog Number . . . . . . . . . . Body Type . . . . . . . . . . . . . . . . . . O-ring . . . . . . . . . . . . . . . . . . . . . . Capacity . . . . . . . . . . . . . . . . . . . . Connection . . . . . . . . . . . . . . . . . ZIVC00142 VALRVT125VPV ZIVC00143 VALRVT200VPV PVC Viton® 4 gpm 1/2" PVC Viton® 8 gpm 3/4" PVC Viton® 15 gpm 1" PVC Viton® 25 gpm 11⁄4" PVC Viton® 50gpm 11⁄2" Polypro Viton® 4 gpm 1/2" Polypro Viton® 8 gpm 3/4" Polypro Viton® 15 gpm 1" Polypro Viton® 50 gpm 11⁄2" Polypro Viton® 80gpm 2" PVC Viton® 80gpm 2" VALRVT050VPP VALRVT075VPP VALRVT100VPP VALRVT150VPP VALRVT200VPP Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 212 WASTEWATER Wastewater Capabilities As the world’s leading provider of industrial and municipal wastewater treatment, Siemens offers the most comprehensive solutions to our customers’ wastewater treatment problems. From groundwater or landfill leachate treatment, to municipal wastewater or zero-discharge facilities, Siemens offers a total solutions approach to wastewater treatment, recovery and reuse. We have the widest range of technologies, products and services to help you minimize operating costs, maximize resources and meet discharge requirements. Siemens provides a complete range of technologies and services for wastewater treatment industry, from pretreatment to effluent discharge and residuals management: Preliminary Treatment/Pre-treatment Intake systems, screens and rakes Grit removal Pumps Flow equalization Aeration Odor control Media filtration Clarification pH adjustment Oil/Water Separation API separators Plate separators Hydrocyclone separators DAF/DGD Separators IAF/IGD Separators Skimmers Walnut shell filters Chemical Precipitation/Neutralization Chemical feed systems Bulk chemical handling Lime slakers Batch and continuous precipitation units Membrane systems Clarification Clarifiers High rate clarification Plate separators Skimmers Flotation systems Sludge collectors Adsorption clarifier-filter systems Residuals Management Spent caustic, spent acid and organic waste management Spent catalyst recovery Biological Treatment Sequencing batch reactors Select or plug flow reactors Multi-channel and single-channel oxidation ditches Surface aerators Jet aerators Fine and coarse bubble aeration Mixers Anaerobic RBCs/SBCs MBR (Membrane Bioreactor) MBBR (Moving Bed Biofilm Reactor) Trickling filters Activated sludge systems and package plants Biological aerator filters Biotowers Powdered activated carbon systems GAC fluid beds Media Advanced fluidized composting Biological nutrient removal Monitoring and control Filtration/Polishing Conventional shallow and deep bed filters Upflow filters Pulsed bed filters Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Main Table of Contents 213 WASTEWATER Wastewater Capabilities Traveling bridge filters Multimedia filters GAC fluid beds Membrane filtration Reverse osmosis Activated carbon Pressure filters Filter underdrains Micro-screens Solids Handling Gravity thickeners Aerobic and anaerobic digestion Belt filter presses Filter presses Pasteurization Sludge dryers Composting Wet air regeneration Incineration Sludge conveyance systems Groundwater, Soil Remediation/ Leachate Treatment Media filters Biological treatment Clarification Metals removal systems Solids handling systems Activated carbon systems In-process Treatment Wet air oxidation Metals removal Coker clarifiers Desalter oil/water separators Selenium removal Evaporation/crystallization Ion exchange UV oxidation Strippers Carbon adsorption Chemical recovery systems Water reuse systems Energy recovery systems Ion exchange Air/VOC/SO2 Treatment & Recovery Odor control Sulfur recovery H2S removal Activated carbon adsorbers Emergency vapor scrubbers VOC/odor containment covers Gas collection and incineration Support Services Laboratory analysis Treatability and pilot plant studies Startup and personnel training Preventative maintenance contracts Rehabilitation and retrofits Service contracts Outsourcing Design-build-own-operate Financing, leasing Centralized treatment Resource recovery For Additional Information on Our Wastewater Capabilities Contact: Siemens Water Technologies 181 Thorn Hill Road Warrendale, PA 15086 toll free 800.525.0658 telephone 724.772.1402 fax 724.772.1300 e-mail information.water@siemens.com Resource Recovery Oil, glycol recovery systems Metal recovery systems Activated carbon recycling and reactivation Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Main Table of Contents This page intentionally left blank BACK Main Table of Contents 215 Support Services TA B L E O F CONTENTS ACTIVATED CARBON TURNKEY SERVICES Adsorber Exchange Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216 Analytical Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216 Carbon Changeout Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216 Reactivation and Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216 ENVIRONMENTAL SERVICES Groundwater Remediation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217 Hazardous Waste Treatment and Recovery . . . . . . . . . . . . . . . . . . . . . .217 Hydrocarbon Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218 Wastewater Ion Exchange Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218 ION EXCHANGE RESIN TURNKEY SERVICES Replacement Resin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219 Resin Cleaning and Reconditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . .219 Resin Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219 Resin Transportation (Bulk) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220 Turnkey Removal and Replacement Services . . . . . . . . . . . . . . . . . . . .220 MAINTENANCE AND OPERATING SERVICES Build-Own-Operate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221 Service Contracts and Preventative Maintenance . . . . . . . . . . . . . . . . .221 Start-Up Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221 Temporary Water Treatment Systems . . . . . . . . . . . . . . . . . . . . . . . . . .222 RO MEMBRANE TURNKEY SERVICES Membrane Care ProgramSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223 Analytical Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223 Off-Site Membrane Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223 Replacement Membranes and Components . . . . . . . . . . . . . . . . . . . . .223 Chemical Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223 SPARE AND MANUFACTURERS’ ORIGINAL PARTS Spare Parts, Expendables and Consumables . . . . . . . . . . . . . . . . . . . .224 Replacement Filtration Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224 Manufacturers’ Original Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224 Replacement Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 Water & Wastewater Data Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 TECHNICAL SERVICES Analytical Water Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226 Application Engineering & Custom System Design . . . . . . . . . . . . . . . .226 Audits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226 Pilot Studies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226 Project Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227 System Optimization Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227 NovaSys – Mechanical Upgrade Program . . . . . . . . . . . . . . . . . . . . . . .228 Documentation and Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229 BACK Main Table of Contents 216 SUPPORT SERVICES Activated Carbon Turnkey Services Siemens Water Technologies is the single source for all your Granular Activated Carbon needs. Our complete line of equipment and Westates® activated carbon products provides the right solution for all your applications, whether industrial, municipal or environmental. We offer turnkey Services to ensure that your equipment continues to operate reliably and economically, while meeting regulatory requirements. From process evaluation and modeling through design, fabrication and installation, to custom on-site service, Siemens has the financial stability and programs to manage your long-term risk. ADSORBER EXCHANGE PROGRAM Offers a simple and cost effective way to handle your removable adsorber equipment tanks. When the adsorber has reached the end of its useful life and the activated carbon inside is “spent”, a local Siemens Water Technologies technician delivers fresh carbon tanks to your site. We can assist with the spent carbon profiling and acceptance procedures necessary for timely removal and reactivation of your spent carbon. After our environmental department approves the profile, we work with you to arrange for pick-up of the spent adsorber(s) and transport to our reactivation facility. ANALYTICAL TESTING Siemens operates a fully equipped carbon testing laboratory that uses ASTM, AWWA and internally developed standard test methods to fully characterize virgin and spent activated carbons. Our laboratory has been certified as an environmental testing laboratory approved for testing hazardous solid wastes for ignitability, corrosivity, toxicity characteristics leaching procedures (TCLP), inorganic metals and organics in accordance with appropriate EPA methods. Wastewater fields of testing include inorganic metals and organics in accordance with EPA methods. CARBON CHANGEOUT SERVICES For systems that are permanent and hard-piped, Siemens offers turnkey carbon changeout services. Our service crew mobilizes on site to remove, package and label the spent carbon in Department of Transportation (D.O.T) approved containers. After removal, inspection of the vessel interior and internal distributors is conducted and minor repairs are made if necessary. The adsorber is refilled with fresh activated carbon and the spent carbon is transported to our RCRA-permitted reactivation facility. REACTIVATION AND RECYCLING Siemens offers the most environmentally sound alternative to disposing of spent carbon in landfills. Our RCRA-permitted reactivation facility recycles used carbon by processing it through a furnace system, removing and destroying inorganic impurities. The recycled carbon exits the reactivation units, is cooled, tested for quality assurance and packaged for reuse. Lot numbers, sampled and analyzed in accordance with Siemens' QA/QC program, identifies the reactivated carbon. The entire state-of-the-art process is computer controlled and monitored, ensuring the facility meets or exceeds federal and state regulatory requirements for air and water discharges. A Certificate of Reactivation can be issued for each shipment of recycled carbon. This certifies that the spent carbon has been recycled in a manner that meets or exceeds all applicable RCRA and Benzene NESHAP regulations. Other turnkey services include: • Design/Engineering • Fabrication/Installation – Lic. Contractor • Mobilization/Removal of Equipment • Dedicated Potable Water Vehicles • Carbon Canister Monitoring • Benzene NESHAPS Monitoring • Transportation Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 217 SUPPORT SERVICES Environmental Services GROUNDWATER REMEDIATION SERVICES Water is our planet’s most valuable natural resource. Faced with the challenges of increasing populations, more stringent government standards and more complex treatment solutions, many municipalities and industries alike are faced with the growing challenge of properly treating their contaminated wells, runoff and other groundwater supplies. Siemens Water Technologies provides the technical know-how and has the costeffective solutions to make treating contaminated waters – whether destined for potable drinking water or non-potable discharge – simplified. Siemens Environmental Services include reliable solutions for dealing with your most difficult contaminated waters issues. Our products and systems are based on the Best Available Technology (BAT) for treating a broad range of contaminants, including: • Arsenic • Chrome, Hexavalent chrome • Iron • Manganese • MTBE (Methyl tertiary-butyl ether) • Nitrates • Perchlorate • Radionuclides • TCE (Trichloroethylene) • VOC (Volatile organic compounds) HAZARDOUS WASTE TREATMENT AND RECOVERY Siemens operates two, fully-permitted facilities with federal RCRA Part B and CERCLA authority for the treatment and recovery of inorganic or trace organic waste. Wastes are sent to the facilities in drums (of all sizes), portable totes, cubic yard bags or boxes and tanker trucks. Virtually everything that we take into our facilities is in some way recycled. Facilities located in Roseville, Minnesota and Los Angeles, California serve as regional hubs for the treatment of hazardous wastewater and the recovery of reusable byproducts. Core industries for this service include: • Printed circuit board manufacturing • Metal finishing • Automotive • Aerospace • Semiconductor manufacturing • Parts washing • Groundwater cleanup • Environmental Contractors • General Industry There are many other industrial wastes that may not be RCRA regulated, but still cannot be discharged to sewer or local landfill. Boiler cleanout, low level metal rinsewaters, parts washer effluent, bag house dust or ammonia water are just a few examples of the variety of non-regulated wastes also processed by Siemens. Our goal is to produce zero hazardous waste by extracting all reusable material, to eliminate pollutants from the environment and avoid disposal costs and liability. Our advanced processing techniques have allowed us to increase beneficial reuse rate of these wastes to over 90% as reusable chemicals and metallic commodities. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 218 SUPPORT SERVICES Environmental Services HYDROCARBON SERVICES When waste generation can‘t be prevented, reuse and recycle are at the top of the EPA’s waste management best practices list. How these materials are managed matters to both the customer and Siemens. Our hydrocarbon services business processes and recycles oily wastes and contaminated water from both commercial and industrial customers. A broad range of treatment and recycling options help simplify our customers’ waste management needs and at the same time ensures complete environmental compliance and minimizes liability. Services range from collection and recycling of used Glycol and antifreeze products, used oil filters, and used oil to oil-water separation and cleaning to emergency response and spill support. While our business is regional, we service all types of customers along the Atlantic seaboard down through the Gulf Coast. WASTEWATER ION EXCHANGE SERVICE Wastewater Ion Exchange (WWIX) is a service-based treatment approach for heavy metals control in dilute wastewater streams. We integrate equipment and service option combinations to meet your discharge requirements, achieve the water quality level needed for reuse while also minimizing your capital investment, reducing overall space requirements and minimizing the liability associated with on-site storage and handling of chemicals. Our Wastewater Ion Exchange (WWIX) systems use specially selected resins and medias to remove soluble heavy metals from various manufacturing processes, cooling systems and contaminated groundwater. Each resin/media has a finite capacity for metals removal. Once this capacity is reached, a Siemens field service technician removes the exhausted tanks and replaces them with fresh tanks. The exhausted resin/media is returned to our RCRA-permitted plant for regeneration and reuse. The byproducts of these regeneration processes are further subjected to a high temperature recovery process that captures the metals for reuse. All residuals are captured as individual metals or sold as part of an iron-rich material used in the production of Portland cement. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 219 SUPPORT SERVICES Ion Exchange Resin Turnkey Services REPLACEMENT RESIN Choose USF™ Ion Exchange Resin As a leader in resin technology, we noticed a trend toward inconsistent performance and quality of resins available in the marketplace. Because of the process guarantees Siemens Water Technologies offers, we are able to produce resins that meet more stringent, tighter resin performance specifications. Thus, USF™ ion exchange resin was established to ensure our customers receive the highest quality product. Advantages of Choosing USF™ Resin • We offer USF™ ion exchange resin at cost savings over equivalent products. • Our QA/QC program is ANSI N45.2, 10CFR50 Appendix B, and 10 CFR21 compliant to meet nuclear safety requirements. • We can provide process performance guarantees upon request. • Extensive technical support and resin application knowledge. We provide Certificates of Analysis, Certificate of Conformance, and Shelf Life statements upon request. RESIN CLEANING AND RECONDITIONING Siemens Water Technologies provides services for salvaging your fouled, crosscontaminated and/or exhausted resin. We can remove resins, transport them to our local processing plant, convert the resins and return them to your facility. This extends their useful life, minimizes costs and reduces system downtime. We can also do this on a scheduled basis for condensate polishing or other water treatment applications. The resin can be transported to and from the job site in our tanker trucks, 55 gallon drums, lined fiber drums, or supersacks. RESIN TESTING To ensure optimum performance from your water treatment system, Siemens recommends periodic testing of your ion exchange resin. Siemens' resin testing facility can determine resin quality, diagnose operating problems and evaluate new ion exchange products for conventional and special liquid processing applications. Our lab can perform the following tests on your resin samples. Standard laboratory resin testing • Capacity before/after clean up steps • Percent moisture • Particles size • Iron Fouling • Microscopic visual examination Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 220 SUPPORT SERVICES Ion Exchange Resin Turnkey Services Additional testing available • Percent conversion • Bead strength • Metallic impurities • Cross contamination • Kinetics (Mix Bed Test) • Kinetics (Mass Transfer) • TOC Extractables • 16 hour soak • Dynamic • Organic Cl, SO4 Extractables • 16 hour soak (UV) • Dynamic (UV) • Parr Bomb • Terminal Settling Velocity (TSV) • Super Fines (-60 mesh) RESIN TRANSPORTATION (BULK) Siemens offers bulk delivery and disposal of resin. We eliminate drum handling by slurrying the resin directly from your water treatment service vessels to one of our fleet of tanker trucks. Whether we’re delivering your own regenerated resin or providing new resin, we greatly reduce the steps involved and the documentation and administrative controls that go with temporary on-site and off-site disposal of resin. TURNKEY REMOVAL AND REPLACEMENT SERVICES When it’s time to remove and replace your existing resin, consider Siemens to handle your needs on a full turnkey basis. Siemens’ team of trained professionals will provide complete project coordination, from predisposal testing through new resin installation to used resin landfill disposal or investment recovery (used resin brokers). We do it all. With complete responsibility in Siemens’ hands, you can be assured that your project will be completed on schedule, within budget and most importantly, in full compliance with all environmental regulations. In addition to being the largest distributor of ion exchange resin, Siemens also provides a full range of resin support services including laboratory testing, removal, cleaning and resin re-conditioning for extended life. We offer special handling, custom packaging or bulk delivery to meet your needs. If you are considering disposal and investment recovery options, we have the expertise to help. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 221 SUPPORT SERVICES Maintenance and Operating Services BUILD-OWN-OPERATE Outsourcing water and wastewater treatment systems has been common over the past 30 years. Because of the vast array of technologies and solutions available, more and more companies are handing this operation over to Siemens Water Technologies. We can provide and evaluate the right technological and economic solutions, since our sole business is the operation of the entire treatment system. This ensures the lowest total treatment cost while insuring maximum on-line operation, guaranteed treated water quality, and the ability to quickly react to unforeseen circumstances. This allows you to focus on your core competency – making your product – while not using capital on projects that do not provide revenue. Companies that rely on outsourced services, however, still maintain strategic control of their operations, both now and in the future. SERVICE CONTRACTS AND PREVENTATIVE MAINTENANCE Siemens offers you peace of mind with our custom service contracts and preventative maintenance agreements. Extended equipment life and efficient operation are direct benefits of selecting Siemens to maintain your water treatment equipment. Our service contracts are custom tailored to help you get the most value from your water treatment equipment investment. The Siemens Water Technologies service template is customized for your equipment and operating parameters. If your equipment is not operating in the normal range, our custom service template will flag it immediately. A follow up letter is sent detailing the condition, corrective action, maintenance requirements, and potential complications if the condition is ignored. This system provides an expert evaluation of your equipment operation on a regular basis. In some cases you may chose to have Siemens perform the necessary maintenance tasks to extend your equipment life. We offer custom preventative maintenance services as part of our service contracts. We include services such as filter re-bedding, ion exchange re-bedding, RO membrane cleaning, and parts replacement such as pump seals, UV bulbs, and cartridge filters. A customized contract allows you to decide the level and frequency of service that is best for your facility. Our factory-trained service technicians are ready to serve you from over 80 offices in North America. Our localized service allows us to schedule service and repairs when you need them. Our local service structure allows us to have fast emergency response and parts availability when you need it. Contact your local branch for a service evaluation for your plant today. START-UP SERVICE Siemens can provide a team of process experts to assist with your system installation and bringing your system on line. Our factory/field project team will assist you with filling all tanks and equipment with production feedwater, monitoring the process through several production cycles and show your production personnel all the process adjustments needed to be sure you’re getting the product water you expect. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 222 SUPPORT SERVICES Maintenance and Operating Services We can also provide complete turnkey service. After defining your process parameters, we will configure the most cost-efficient system, install the equipment, fully test the process, train your personnel and provide guarantees regarding product water. Many companies find this minimizes the demands on their own resources and personnel. TEMPORARY WATER TREATMENT SYSTEMS For over 30 years, Siemens has met the short-term and emergency treated water needs of our customers using our mobile water treatment systems. Units may be installed in your plant and operated as stand-alone units or installed inside a trailer and controlled by the system panel. Units can be combined with other Siemens products to assemble fully integrated water treatment systems designed to customers’ specific treated water quality and flow needs. MOBILE SYSTEMS INCLUDE: • FlexRO® – Skid-mounted, self-contained, 100 gpm reverse osmosis units that feature 3:2:1 (4M) array skids. • FlexTrex® – Skid-mounted ion exchange units that are designed to treat flows ranging from 20 to 250 gpm per unit. Regenerated off-site, these portable units do not use hazardous chemicals, do not generate wastewater and are ideal for polishing raw or RO permeate water. • PreFlex® – Units are modular in design, pre-plumbed, self-contained, skidmounted pretreatment units. They are designed to the highest engineering standards with ASME code tanks, NEMA 4X panels and pneumatically actuated solenoid valves enabling them to be used in a wide variety of applications and environments including heavy industry. • Mobile Clarifier Trailers – Self-contained, trailer-mounted system capable of treating highly turbid water (>1000 NTU). The system is capable of producing extraordinarily clear effluent (0.5-1.0 NTU) with remarkable stability under varying raw water conditions. Flow rates to 1,050 gpm. • Mobile Demineralizer (DI) Trailers – These trailers are the treatment of choice for zero-discharge applications and seasonal treated water needs. With regeneration facilities across the country and a large fleet of over 80 service branches, Siemens can respond quickly to your emergency treated water needs. • Mobile RO (Reverse Osmosis) Trailers – Self-contained, trailer-mounted systems that can be configured with combinations of 4 skid-mounted FlexRO-100 units. Systems have flow rates up to 400 gpm per trailer. TYPICAL USES: • Facility expansions • Pilot plant water needs • Interim use until a permanent system is installed • Process water/treated water quality changes • Environmental salt discharge problems • Emergency/scheduled shutdowns • Seasonal water needs Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 223 SUPPORT SERVICES RO Membrane Turnkey Services MEMBRANE CARESM PROGRAM Our Membrane CareSM Program provides the services to keep your reverse osmosis (RO) system operating at peak performance. In addition to our large inventory of membranes and replacement parts, our trained service technicians can provide assistance with membrane removal and installation or membrane cleaning, either onsite utilizing your clean-in-place skid or off-site at one of our regional cleaning facilities. We offer membrane autopsies and complete laboratory services to evaluate system performance and improve productivity. ANALYTICAL SERVICES Siemens’ analytical testing includes feedwater and outlet water analyses and various membrane analytical techniques. Our Membrane Center of Excellence can provide feed, concentrate and permeate water analyses, SDI pad analyses and various nondestructive and destructive tests. Membrane analysis assists in identifying the fouling agent(s), proper cleaning techniques and proper pretreatment methods to prevent recurring fouling. OFF-SITE MEMBRANE CLEANING Siemens’ off-site cleaning process is specifically designed to restore RO membranes to or near the original manufacturer’s performance specifications. Our proprietary equipment and strict cleaning process are tightly controlled to ensure optimum cleaning performance, resulting in longer intervals between cleanings and/or replacement. The cleaning process does not affect the structural integrity of the membrane and, therefore, does not void the manufacturer’s warranty. Siemens Water Technologies offers three levels of off-site cleaning service for your 4” and 8” elements. REPLACEMENT MEMBRANES AND COMPONENTS Siemens is your leading source for replacement membranes. We supply elements from all of the major manufacturers. For your convenience, we inventory FILMTEC™ and Hydranautics® membranes at our seven regional distribution facilities. This enables us to meet short lead times and thereby minimize your system’s downtime. In addition, our regional distribution facilities also stock major components, such as replacement gauges, pumps and end caps. CLEANING CHEMICALS Siemens can determine the source of your membrane fouling problem and make recommendations on the selection and purchase of proper chemical treatments and, if necessary, appropriate pretreatment steps. Our broad membrane system expertise enables us to provide reliable diagnosis methods and sound troubleshooting to return your equipment to optimum performance. We work with all the RO chemical manufacturers and provide you with the best combination of RO antiscalants, chemical feed systems and dosing rates to keep your RO system running smoothly. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 224 SUPPORT SERVICES Spare and Manufacturers’ Original Parts SPARE PARTS, EXPENDABLES & CONSUMABLES (Filter Cartridges, UV Bulbs, Gaskets, Nuts, Bolts, Piping) We have the largest inventory of spare and replacement parts in the industry. If you need filter elements, UV components, replacement gauges or controls, we stock these as well as other parts. We supply both industrial grade products and validated pharmaceutical bacteria-removal cartridges. We have filter housings for every purpose, from simple plastic construction to an electro-polished, sanitary pharmaceutical design. Our complete line of sterilizers deliver flows of 1 gpm to 1,000 gpm. These systems can be designed to reduce bacterial contamination and destroy TOC (total organic carbon) materials in the supply water. We also provide replacement and spare parts for your ancillary system components, such as pumps, valves and gaskets. Whether it involves normal wear-and-tear replacement, maintenance or spares inventory, we will help ensure your water treatment systems operate efficiently with minimal downtime. REPLACEMENT FILTRATION MEDIA We offer a wide variety of filtration medias and underbedding materials for every filtration application. These include sand, garnet, gravel, anthracite or quartz materials screened to the specific mesh sizes required. We also offer media removal, vessel and distribution inspection, installation of the new media plus disposal of the spent media if required. MANUFACTURERS’ ORIGINAL PARTS We provide components for equipment names you are familiar with in the Siemens family, including Illinois Water Treatment (IWT®), Permutit®, L*A Water, Kisco™, Ionpure® and Polymetrics™, to name a few. From vessel replacements to internals and Permutit multiport valves, Siemens is the only company that can ensure the parts you buy are designed and engineered to fit your original equipment. Our library of original installation drawings ensures all replacement components are completely compatible with existing systems. CALL THE NUMBER BELOW TO ORDER PARTS FOR EQUIPMENT MADE BY THESE SIEMENS COMPANIES. Arrowhead® Industrial Water 1-800-875-7873 ext. 5000 Continental® 1-800-875-7873 ext. 5000 Interlake 1-800-875-7873 ext. 5000 Ionpure® 1-800-875-7873 ext. 5000 IWT® (Illinois Water Treatment) 1-800-582-5261 Kisco™ 1-800-582-5261 L*A Water 1-800-582-5261 Mitco 1-800-875-7873 ext. 5000 Penfield® 1-800-875-7873 ext. 5000 Permutit® 1-800-631-0878 ext. 107, 108 Polymetrics™ 1-800-875-7873 ext. 5000 Water Services of America 1-800-875-7873 ext. 5000 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 225 SUPPORT SERVICES Manufacturers’ Original Parts MANUFACTURERS’ ORIGINAL PARTS SPECIALIZED OR PROPRIETARY ITEMS REPLACEMENT TANKS (PRESSURIZED AND ATMOSPHERIC) VESSEL REPAIRS AND UPGRADES Whether it is a system supplied by Siemens, a legacy company or any/all other water treatment manufacturers, we can assist you with specialized or proprietary items including: • Rupture disks • Bushings • Shafts • Chevron tube settlers • Sampling devices/sinks • Desiccant breathers/fume vents – • Sight windows including designs using dyed resins • Socket agitator arms • Distribution systems – complete • Strainers and strainer baskets – systems or individual components conventional, dual velocity, specialty, • Face piping underdrain, etc. – including • Gauge glasses polystyrene, PVC and stainless steel • Inlet diffusers construction • Level switches • Thermometers • Nozzles – conventional, dual velocity, • Vacuum breakers spray, etc. • Valve inspection and repair • Overflow controls/traps • Valve retrofits – manual to automatic • Packing for deaerating heaters, • Valves, maintenance kits and parts – decarbonators, degasifiers, etc. inlet, control, pressure relief, spray, • Pillow blocks multiport, etc. • Pressure gauges • Vent condensers • Rotary surface washers Some of the tanks, vessels and vessel repairs that we can provide: • ASME code and non-code designs • Chemical regeneration tanks (acid, caustic and brine) • Custom designed tanks • Double dish design • Exact replacements • Fiberglass tanks • Flat false bottom vessels • Replacement tanks for neutralization systems • Replacing tank liners on-site • Spray lined and rubber lined vessels – including FDA compliant linings • Storage tanks For additional information, call 800.582.5261 ext. 378. PERMUTIT® WATER AND WASTEWATER TREATMENT DATA BOOK As advertised for years by Permutit, “We wrote the book on water treatment”. The latest edition of this popular, 166-page engineering data book contains charts, graphs and illustrations for general water data, pipes and fittings, chemical properties and data, and waste treatment information. The book is a useful tool for all individuals involved in the design of water and wastewater treatment systems, pollution control and water recovery and reuse. To order copies or for additional information, contact 1-800-631-0878, ext. 107, 108. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 226 SUPPORT SERVICES Technical Services ANALYTICAL WATER TESTING Before you can select the right combination of technologies to deliver the level of water quality that you need, it is essential to know exactly what is in your water. Siemens' analytical testing laboratory offers complete testing services to determine the most appropriate system components to meet each customer’s particular application needs. The water analysis and research and development laboratories conduct a wide range of tests designed to accommodate the analysis of water for all applications, including pharmaceuticals, high-purity water, hemodialysis, laboratory, pretreatment and troubleshooting. The laboratory has the capacity to perform inorganic analysis and TOC testing. We offer postage-paid water analysis test kits designed to address a variety of field requirements. Once a test kit is returned to the lab, we tailor the testing and reporting to meet specific customer requirements. Comprehensive reports are generated and the laboratory maintains an extensive database. APPLICATION ENGINEERING & CUSTOM SYSTEM DESIGN Siemens offers customized water treatment systems in addition to standard, preengineered products. The scope of our involvement in a project is determined by the needs of the customer, the types of technologies being evaluated and the complexity of the treatment solution being considered. Designers, drafters and engineers in our CAD/CAE (computer-aided design/computer-aided engineering) group work together with manufacturing, R&D and sales personnel to develop equipment and system designs for a broad scope of treatment needs. They have extensive experience in process water filtration and CAD/CAE, with specific expertise in piping design, process instrumentation, steel weldment fabrication, tooling, electrical design, panel layout and programming. When you need a continuous supply of high-purity water for your critical application, consult with our water treatment experts to determine the most effective and efficient system to continuously and consistently meet those needs. AUDITS One of the many services Siemens offers to help customers manage their water and wastewater treatment are plant audits. These completely confidential audits, conducted by our specially trained audit teams, help customers solve a specific problem or improve their plant operations. PILOT STUDIES We offer process water and wastewater treatment pilot systems representing various technologies so you can test the technology on your application before you buy. Among our pilot plant capabilities is the industry’s most complete test facility for biological processes and aeration, the world’s only complete wet air oxidation plant and equipment for testing dewatering processes, pumping and filtrations. Many of our pilot facilities are trailer or skid-mounted, so you can test various processes on your wastewater at your site – under operating conditions. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 227 SUPPORT SERVICES Technical Services PROJECT MANAGEMENT Each water or wastewater treatment system we manufacture and install is project managed by an expert focused on the needs of your industry. From initial problem analysis to system start-up, we’ll work with your team to ensure a successful treatment project that meets your requirements. Our biopharmaceutical design/build and program management group offers design/build capabilities; pre-engineered/modular constructed equipment and process systems (skid) applications. We also offer turnkey project management. SYSTEM OPTIMIZATION PROGRAM For existing water treatment systems that are not operating at optimum efficiency, Siemens offers the System Optimization Program to enhance system performance. The program is offered through Siemens' Engineered Parts and Services (EP&S) group. Through the program, an EP&S Technical Services Engineer will: • Travel to the site. • Conduct a comprehensive review of the water treatment system and ancillary equipment. • Meet with operating personnel to determine current maintenance procedures and operating conditions. • Review operating data and sequences, drawings and operating and maintenance manuals. • Provide a detailed engineering report, including observations and recommendations. Services are available on a per diem basis and can include engineering consulting, process troubleshooting, equipment evaluation and optimization and an optional Process Optimization Modeling Report. Using Siemens' WinCPD® proprietary computer simulation program, a Process Optimization Modeling Report will be generated. Allowing a multitude of variables withing the water treatment system to be analyzed, the WinCPD® program wil them model the most effective operating parameters for the system. The program includes water treatment systems supplied through Siemens' family of companies including systems previously supplied by: • • • • • • Continental® Water Systems Corporation Himsley Engineering Ltd./Himsley International Interlake Water Systems Company Ionpure® Illinois Water Treatment (IWT®) Kisco® • • • • • • L*A Water Mitco Penfield® Permutit® Polymetrics® Water Services of America We are also well qualified to perform evaluations on water treatment systems supplied by all other manufacturers. For additional information, call 800.582.5261 ext. 342 or 340. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 228 SUPPORT SERVICES Technical Services NOVASYS – MECHANICAL UPGRADE PROGRAM After years of usage, a water treatment system may be showing signs of deterioration. The vessel or piping may be corroded or leaking or various components may not be functioning properly. In other instances, the technology may have changed offering better efficiencies. Through NovaSys, one of our inspectors will travel to the site, perform a thorough system analysis and submit a detailed list of recommendations. Suggestions for alternative materials of construction and/or designs will be included within the recommendations to reduce costs and improve safety and operating efficiencies. As part of the program, we can replace worn or outdated: • Tanks (repairs are also available) • Piping manifolds • Internals and other distribution systems • Valves, strainers, pumps and other components • Resins and other media We will also offer recommendations for upgrading the system. Typical NovaSys upgrades that we supply include: • Changing conventional downflow softeners and two bed deionizers (also called separate beds) into highly efficient packed bed systems • Upgrading internal tank distribution systems for greater reliability • Using Siemens' patented Heat Optimized Technology (HOT Series) to transform typical carbon towers into hot water sanitizable carbon filters to control effluent biological growth • Upgrading regeneration chemical skids (pumped or educted systems) for improved performance Some of the advantages of Siemens' NovaSys Mechanical Upgrade Program include: • Improves safety by minimizing burst and leak risks • Eliminates downtime for increased productivity • Provides consistent water quantity and quality • Saves costs because less chemicals are consumed • Improves pump performance for better chemical utilization • Corrects dosages and flow rates for improved regeneration times • Reduces maintenance labor and parts • Reduces utility costs through reduced water usage For additional information, call 800.582.5261 ext. 340. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 229 SUPPORT SERVICES Technical Services DOCUMENTATION AND VALIDATION Siemens understands that process validation of the entire water treatment system is an important concern, and often a hidden cost, to our pharmaceutical customers. That’s why we offer systems that are designed with validation in mind. These systems incorporate proven equipment components and instrumentation that makes date monitoring more convenient for systems operators. We regularly install programmable logic control (PLS) validated systems that continuously and automatically monitor and record critical parameters. We offer a full range of validation support documents with our pharmaceutical and biotechnology system designs. We also provide copies of our documented, established quality control procedures for hemodialysis reverse osmosis water systems and hemodialysis resin regeneration centers. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents This page intentionally left blank BACK Section Table of Contents 231 Water Quality Standards, Constants, Conversions & Physical Data TA B L E O F CONTENTS REFERENCE INFORMATION TABLES Conductivity and Resistivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 ASTM Reagent Water. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 Clinical Laboratory Standards Institute. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 USP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 AAMI Hemodialysis Water Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 U.S. Boiler Feedwater Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 Langelier Saturation Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 Calcium Carbonate Equivalents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 Equivalents of Liquid Measures and Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 Pressure and Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 Centigrade (°C) to Fahrenheit (°F). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 Tank Areas and Volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 A Key to Relative Particle Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 Velocity of Liquids in Pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 BACK Main Table of Contents This page intentionally left blank Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Main Table of Contents 233 REFERENCE TABLES Conductivity and Resistivity (CaCO3 solutions at 25°C) Conductivity (micromhos-cm) Resistivity (ohms-cm) 0.056 0.059 0.063 0.067 0.072 0.077 0.084 0.091 0.100 0.111 0.125 0.143 0.167 0.200 0.250 0.333 0.500 1.00 1.11 1.25 1.43 1.67 2.00 2.50 3.33 5.00 10.0 11.1 12.5 14.3 16.7 20.0 25.0 33.0 50.0 100.0 111.0 125.0 143.0 167.0 200.0 250.0 333.0 500.0 1000.0 Resistivity/Conductivity ohm-cm = ___1_____ mho/cm 18,000,000 17,000,000 16,000,000 15,000,000 14,000,000 13,000,000 12,000,000 11,000,000 10,000,000 9,000,000 8,000,000 7,000,000 6,000,000 5,000,000 4,000,000 3,000,000 2,000,000 1,000,000 900,000 800,000 700,000 600,000 500,000 400,000 300,000 200,000 100,000 90,000 80,000 70,000 60,000 50,000 40,000 30,000 20.000 10,000 9,000 8,000 7,000 6,000 5,000 4,000 3,000 2,000 1,000 = _____1____ Siemens/cm Dissolved Solids (parts per million) (as CaCO3) 0.0277 0.0294 0.0313 0.0333 0.0357 0.0384 0.0417 0.0455 0.0500 0.0556 0.0625 0.0714 0.0833 0.100 0.125 0.167 0.250 0.500 0.556 0.625 0.714 0.833 1.00 1.25 1.67 2.50 5.00 5.56 6.25 7.14 8.33 10.0 12.5 16.7 25.0 50.0 55.6 62.5 71.4 83.3 100.0 125.0 167.0 250.0 500.0 Conversions Grains/Gallon (as CaCO3) 0.00164 0.00170 0.00181 0.00193 0.00211 0.00222 0.00240 0.00263 0.00292 0.00322 0.00368 0.00415 0.00485 0.00585 0.00731 0.00971 0.0146 0.0292 0.0322 0.0368 0.0415 0.0485 0.0585 0.0731 0.0971 0.146 0.292 0.322 0.368 0.415 0.485 0.585 0.731 0.971 1.46 3.22 3.22 3.68 4.15 4.85 5.85 7.31 9.71 14.6 29.2 Total Dissolved Solids 1 grain per gallon = 17.1 parts per million (ppm) 1 part per million = 1 milligram per liter (mg/l) Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 234 REFERENCE TABLES ASTM® Reagent Water Specifications CLSI® (formerly NCCLS) Reagent Water Specifications USP® 30 Pharmaceutical Grade Water Standard AMERICAN SOCIETY FOR TESTING AND MATERIALS Standard Specifications for Reagent Water ASTM Type I Conductivity @ 25°C (micromhos/cm) . . . . . . . . . . Resistivity @ 25°C (Megohms-cm). . . . . . . . . . . . . Total Silica (µg/L) . . . . . . . . . . . . . . . . . . . . . . . . . . Total Organic Carbon (µg/L) . . . . . . . . . . . . . . . . . . Chlorides (µg/L) . . . . . . . . . . . . . . . . . . . . . . . . . . . Sodium (µg/L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pH* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.056 . . . . . . 18 . . . . . . . . . 3 ......... 100 . . . . . . . . . 1 ......... 1 ......... – ......... Max Heterotropic Bacteria Count . . . . . . . . . . . . . . Endotoxin, EU/mL . . . . . . . . . . . . . . . . . . . . . . . . . . 10/1000 mL. . . < 0.03 . . . . . . . II 1.0 . . . . . . . 1.0 . . . . . . . 3. . . . . . . . . 50. . . . . . . . . 5. . . . . . . . . 5. . . . . . . . . –. . . . . . . . . Type A Type B 10/100 mL . . . 0.25 . . . . . . . . III 0.25 . . . . . . . . 4.0 . . . . . . . . . 500 . . . . . . . . . . 200 . . . . . . . . . . 10 . . . . . . . . . . 10 . . . . . . . . . . – .......... IV 5.0 0.2 – – 50 50 5.0-8.0 Type C 100/10 mL N/A *The measurement of pH in Type I, II, and III reagent water has been eliminated because these grades of water do not contain constituents in sufficient quantity to alter pH. CLSI (CLINICAL LABORATORY STANDARDS INSTITUTE)* Clinical Laboratory Reagent Water (CLRW) CLSI Resistivity @ 25°C . . . . . . . . . . . . . . . . . . . . . . . . . (megohms-cm) Conductivity @ 25°C . . . . . . . . . . . . . . . . . . . . . . . (micromhos/cm) Bacterial Growth (cfu/mL) . . . . . . . . . . . . . . . . . . . . Organics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Particulate Matter . . . . . . . . . . . . . . . . . . . . . . . . . . a 10 0.1 10 a <500 ppb a 0.22 µm Filter This specification is a process specification, and not measured by the end-user. *Formerly NCCLS (National Committee for Clinical Laboratory Standards). UNITED STATES PHARMACOPOEIA 30 STANDARDS USP 30 Pharmaceutical Grade Water Organics . . . . . . . . . . . . . . . . . . . . . . . . . . <0.5 ppm TOC Endotoxin by LAL Purified Water . . . . . . . . . . . . . . . . . . . . WFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . No specification <0.25 EU/mL Conductivity . . . . . . . . . . . . . . . . . . . . . . . Bacteria (guideline only) Purified Water . . . . . . . . . . . . . . . . . . . . WFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . <1.3 µS/cm at 25°C in-line measurement** <100 cfu/mL <10 cfu/100 mL **from equivalent values from USP Table for Conductivity Limits as a Function of Temperature. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 235 REFERENCE TABLES Association for the Advancement of Medical Instrumentation(AAMI) Hemodialysis Water Quality Maximum allowable chemical contaminant levels in water used to prepare dialysate and concentrates from powder at a dialysis facility and to reprocess dialyzers for multiple usea. Contaminant Aluminum. . . . . . . . . . . . . . . . . . . . Antimony . . . . . . . . . . . . . . . . . . . . Arsenic. . . . . . . . . . . . . . . . . . . . . . Barium . . . . . . . . . . . . . . . . . . . . . . Beryllium . . . . . . . . . . . . . . . . . . . . Cadmium . . . . . . . . . . . . . . . . . . . . Calcium . . . . . . . . . . . . . . . . . . . . . Chloramines. . . . . . . . . . . . . . . . . . Chromium . . . . . . . . . . . . . . . . . . . Copper . . . . . . . . . . . . . . . . . . . . . . Fluoride . . . . . . . . . . . . . . . . . . . . . Free Chlorine. . . . . . . . . . . . . . . . . Lead. . . . . . . . . . . . . . . . . . . . . . . . Magnesium . . . . . . . . . . . . . . . . . . Mercury . . . . . . . . . . . . . . . . . . . . . Nitrate (as N) . . . . . . . . . . . . . . . . . Potassium . . . . . . . . . . . . . . . . . . . Selenium . . . . . . . . . . . . . . . . . . . . Silver . . . . . . . . . . . . . . . . . . . . . . . Sodium. . . . . . . . . . . . . . . . . . . . . . Sulfate . . . . . . . . . . . . . . . . . . . . . . Thallium . . . . . . . . . . . . . . . . . . . . . Zinc . . . . . . . . . . . . . . . . . . . . . . . . Maximum Concentration (mg/L)b 0.01 0.006 0.005 0.10 0.0004 0.001 2 (0.1 mEq/L) 0.10 0.014 0.10 0.20 0.50 0.005 4 (0.3 mEq/L) 0.0002 2.00 8 (0.2 mEq/L) 0.09 0.005 70 (3.0 mEq/L) 100.00 0.002 0.10 a) The physician has the ultimate responsibility for ensuring the quality of water used for dialysis. b) Unless otherwise noted. Water Bacteriology/Endotoxins Product water used to prepare dialysate or concentrates from powder at a dialysis facility, or to reprocess dialyzers for multiple use, should contain a total viable microbial count of less than 200 CFU/mL and an endotoxin concentration of less than 2 EU/mL. The action level for the total viable microbial count in the product water shall be 50 EU/mL and the action level for the endotoxin concentration shall be 1 EU/mL. If these action levels are observed in the product water, corrective measures, such as disinfection and retesting, shall be taken promptly to reduce the levels to an acceptable range. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 236 REFERENCE TABLES Boiler Feedwater Requirements U.S. BOILER FEEDWATER REQUIREMENTS Boiler H.P. 50 75 100 150 175 200 225 250 275 300 350 400 500 750 1,000 1,500 2,000 2,500 3,000 4,000 4,500 5,000 10,000 15,000 20,000 25,000 35,000 40,000 45,000 50,000 60,000 80,000 100,000 ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ ............ gpm 4............. 5............. 7............. 10 . . . . . . . . . . . . . 12 . . . . . . . . . . . . . 14 . . . . . . . . . . . . . 16 . . . . . . . . . . . . . 17 . . . . . . . . . . . . . 19 . . . . . . . . . . . . . 21 . . . . . . . . . . . . . 24 . . . . . . . . . . . . . 28 . . . . . . . . . . . . . 34 . . . . . . . . . . . . . 53 . . . . . . . . . . . . . 69 . . . . . . . . . . . . . 104 . . . . . . . . . . . . . 138 . . . . . . . . . . . . . 172 . . . . . . . . . . . . . 207 . . . . . . . . . . . . . 276 . . . . . . . . . . . . . 310 . . . . . . . . . . . . . 345 . . . . . . . . . . . . . 689 . . . . . . . . . . . . . 1,034 . . . . . . . . . . . . . 1,387 . . . . . . . . . . . . . 1,723 . . . . . . . . . . . . . 2,413 . . . . . . . . . . . . . 2,759 . . . . . . . . . . . . . 3,102 . . . . . . . . . . . . . 3,447 . . . . . . . . . . . . . 4,136 . . . . . . . . . . . . . 5,515 . . . . . . . . . . . . . 6,894 . . . . . . . . . . . . . pound/hour 1,725 2,587 3,450 5,175 6,037 6,900 7,762 8,625 9,847 10,350 12,075 13,800 17,250 25,875 34,500 51,750 69,000 86,250 103,500 138,000 155,250 172,500 345,000 517,500 690,000 862,500 1,207,500 1,380,000 1,550,000 1,725,000 2,070,000 2,760,000 3,450,000 Notes: • gpm is given to the nearest whole number • The above water quantities are based on 34.5 lb. of water evaporated per hour at 212°F. The weight of 1 gallon of water is taken as being equal to 8.34 lb. at 60°F. Intermediate water quantities in gpm are obtainable by multiplying the boiler horsepower by 0.069. • In selecting boiler feed pumps, the fact that boilers are often run 200 or 300 percent of rating should be taken into consideration. The above figures are of the actual boiler horsepower developed. • Boiler feed pumps should have pressure in excess of the boiler rated pressure in order to compensate for frictional losses, entrance losses, regulating valve losses and normal static head. These should be specified for a particular installation. However, for estimating purposes, the following values apply. Boiler Pressure Feed Pump Discharge Pressure 200 psi. . . . . . . . . . . . . . . 250 psi 400 psi. . . . . . . . . . . . . . . 475 psi 800 psi. . . . . . . . . . . . . . . 925 psi 1,200 psi . . . . . . . . . . . . . 1,350 psi Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 237 REFERENCE TABLES Langelier (CaCO3) Saturation Index (Based on the Langelier Formula: Larson-Buswell: Residue-Temperature- Adjustments: Arranged by Nordell) TABLE A: Total Solids/ppm ppm 50 75 100 150 200 300 400 600 800 1000 2000 3000 4000 5000 6000 0.07 0.08 0.10 0.11 0.13 0.14 0.16 0.18 0.19 0.20 0.23 0.25 0.26 0.26 0.28 TABLE B: Temperatures in °F Units Tens 0 2 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 2.48 2.34 2.20 2.06 1.95 1.84 1.74 1.65 1.57 1.48 1.40 1.32 1.26 1.19 2.60 2.45 2.31 2.17 2.04 1.92 1.82 1.72 1.64 1.55 1.46 1.38 1.31 1.24 1.18 1. pHs = (9.30 + A + B) – (C + D) 4 2.57 2.43 2.28 2.14 2.03 1.90 1.80 1.71 1.62 1.53 1.44 1.37 1.29 1.23 1.17 6 2.54 2.40 2.25 2.11 2.00 1.88 1.78 1.69 1.60 1.51 1.43 1.35 1.28 1.22 1.16 (Note. Values of A, B, C, & D are obtained from tables A, B, C, & D) 8 2. Saturation Index = pH – pHs 2.51 2.37 2.22 2.09 1.97 1.86 1.76 1.67 1.58 1.50 1.41 1.34 1.27 1.21 If index is 0, water is in chemical balance. If index is plus quantity, scale forming tendencies are indicated. If index is a minus quantity, corrosive tendencies are indicated. Example: To find the saturation index at 124°F of water which has the following characteristics: Total solids – 400 ppm; calcium hardness as CaCO3240 ppm; alkalinity, and as CaCO3-196 ppm; and pH of 7.2 Then: Total solids . . . . . . . . . . . . . . . . . . Temperature . . . . . . . . . . . . . . . . . Calcium hardness as CaCO3 . . . . . Alkalinity as CaCO3 . . . . . . . . . . . . 400 ppm =0.16 (from table A) 124°F =1.53 (from table B) 240 ppm = 1.98 (from lower table C ) 196 ppm = 2.29 (from upper table D) Substituting: pHs = (9.30 + 0.16 + 1.53 ) – (1.98 + 2.29) = 6.72 (or 6.7) Saturation Index = 7.2 – 6.7 = +0.5 TABLE C: Calcium Hardness Expressed as ppm CaCO3 (for 3 to 209 ppm CaCO3, use upper table; for 210 to 990 ppm CaCO2, use lower table) TABLE D: Alkalinity Expressed as ppm CaCO3 (for 1 to 209 ppm CaCO3, use upper table; for 210 to 990 ppm CaCO2, use lower table) Tens Tens 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Hundreds 200 300 400 500 600 700 800 900 Units 0 1 2 0.60 0.90 1.08 1.20 1.30 1.38 1.45 1.51 1.56 1.60 1.64 1.68 1.72 1.75 1.78 1.81 1.83 1.86 1.88 1.90 0.64 0.92 1.09 1.21 1.31 1.39 1.45 1.51 1.56 1.61 1.65 1.68 1.72 1.75 1.78 1.81 1.84 1.86 1.88 1.91 Tens 0 10 2.08 2.20 2.30 2.38 2.45 2.51 2.56 1.92 2.09 2.21 2.31 2.39 2.45 2.51 2.56 3 4 5 6 7 8 9 0.68 0.94 1.11 1.23 1.32 1.39 1.46 1.52 1.57 1.61 1.65 1.69 1.72 1.75 1.78 1.81 1.84 1.86 1.89 1.91 0.08 0.72 0.96 1.12 1.24 1.33 1.40 1.47 1.52 1.57 1.61 1.66 1.69 1.73 1.76 1.79 1.81 1.84 1.86 1.89 1.91 0.20 0.75 0.98 1.13 1.25 1.34 1.41 1.47 1.53 1.58 1.62 1.66 1.70 1.73 1.76 1.79 1.82 1.84 1.87 1.89 1.91 0.30 0.78 1.00 1.15 1.26 1.34 1.42 1.48 1.53 1.58 1.62 1.66 1.70 1.73 1.76 1.79 1.82 1.85 1.87 1.89 1.91 0.38 0.81 1.02 1.16 1.26 1.35 1.42 1.48 1.54 1.58 1.63 1.67 1.70 1.74 1.77 1.80 1.82 1.85 1.87 1.89 1.92 0.45 0.83 1.03 1.17 1.27 1.36 1.43 1.49 1.54 1.59 1.63 1.67 1.71 1.74 1.77 1.80 1.82 1.85 1.87 1.90 1.92 0.51 0.86 1.05 1.18 1.28 1.37 1.43 1.49 1.55 1.59 1.64 1.67 1.71 1.74 1.77 1.80 1.83 1.85 1.88 1.90 1.92 0.56 0.88 1.06 1.19 1.29 1.37 1.44 1.50 1.55 1.60 1.64 1.68 1.71 1.75 1.78 1.80 1.83 1.85 1.88 1.90 1.92 20 30 40 50 60 70 80 90 1.94 2.11 2.23 2.32 2.39 2.46 2.52 2.57 1.96 2.12 2.24 2.33 2.40 2.47 2.52 2.57 1.98 2.13 2.25 2.34 2.41 2.47 2.53 2.58 BACK 2.00 2.15 2.26 2.34 2.42 2.48 2.53 2.58 2.02 2.16 2.26 2.35 2.42 2.48 2.54 2.58 2.03 2.17 2.27 2.36 2.43 2.49 2.54 2.59 2.05 2.18 2.28 2.37 2.43 2.49 2.55 2.59 2.06 2.19 2.29 2.37 2.44 2.50 2.55 2.60 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Hundreds 200 300 400 500 600 700 800 900 Units 0 1 1.00 1.30 1.48 1.60 1.70 1.78 1.85 1.90 1.95 2.00 2.04 2.08 2.11 2.15 2.18 2.20 2.23 2.26 2.28 2.30 0.00 1.04 1.32 1.49 1.61 1.71 1.79 1.85 1.91 1.96 2.00 2.05 2.08 2.12 2.15 2.18 2.21 2.23 2.26 2.28 2.30 2.48 2.60 2.70 2.78 2.85 2.90 2.95 2.32 2.49 2.61 2.71 2.79 2.85 2.91 2.96 Tens 0 10 2 3 4 5 6 7 8 0.30 1.08 1.34 1.51 1.62 1.72 1.79 1.86 1.91 1.96 2.01 2.05 2.09 2.12 2.15 2.18 2.21 2.23 2.26 2.28 2.30 0.48 1.11 1.36 1.52 1.63 1.72 1.80 1.86 1.92 1.97 2.01 2.05 2.09 2.12 2.16 2.18 2.21 2.24 2.26 2.29 2.31 0.60 1.15 1.38 1.53 1.64 1.73 1.81 1.87 1.92 1.97 2.02 2.06 2.09 2.13 2.16 2.19 2.21 2.24 2.26 2.29 2.31 0.70 1.18 1.40 1.54 1.65 1.74 1.81 1.88 1.93 1.98 2.02 2.06 2.10 2.13 2.16 2.19 2.22 2.24 2.27 2.29 2.31 0.78 1.20 1.42 1.56 1.66 1.75 1.82 1.88 1.93 1.98 2.03 2.06 2.10 2.13 2.16 2.19 2.22 2.24 2.27 2.29 2.31 0.85 1.23 1.43 1.57 1.67 1.76 1.83 1.89 1.94 1.99 2.03 2.07 2.10 2.14 2.17 2.20 2.23 2.25 2.27 2.29 2.32 0.90 1.26 1.45 1.58 1.68 1.76 1.83 1.89 1.94 1.99 2.03 2.07 2.11 2.14 2.17 2.20 2.23 2.25 2.27 2.30 2.32 20 30 40 50 60 70 80 2.34 2.51 2.62 2.72 2.79 2.86 2.91 2.96 2.36 2.52 2.63 2.72 2.80 2.86 2.92 2.97 2.38 2.53 2.64 2.73 2.81 2.87 2.92 2.97 2.40 2.54 2.65 2.74 2.81 2.88 2.93 2.98 2.42 2.56 2.66 2.75 2.82 2.88 2.93 2.98 2.43 2.57 2.67 2.76 2.83 2.89 2.94 2.99 2.45 2.58 2.68 2.76 2.83 2.89 2.94 2.99 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 9 0.95 1.29 1.46 1.59 1.69 1.77 1.84 1.90 1.95 2.00 2.04 2.08 2.11 2.14 2.17 2.20 2.23 2.25 2.28 2.30 2.32 90 2.46 2.59 2.69 2.77 2.84 2.90 2.95 3.00 238 REFERENCE TABLES Calcium Carbonate Equivalents Formula, Atomic, Molecular and Equivalent Weights and Conversion Factors to CaCO3 of Substances Frequently Appearing in the Chemistry of Water Treatment Substance Formula Aluminum Aluminum Chloride Aluminum Chloride Aluminum Sulfate Aluminum Sulfate Aluminum Hydrate Al AlCl3 AlCl3 6H2O Al2(SO4)3;18H2O Al2(SO4)3 (anhydrous) Al(OH)3 Alumina Sodium Aluminate Ammonium Alum Atomic or Molecular Weight Equivalent Weight 27.0 133.2 241.5 666.4 342.1 78.0 9.0 44.4 80.5 111.1 57.0 26.0 Al2O3 Na2Al2O4 101.9 163.9 2SO4 24H2O 906.6 Al2(SO4)3 (NH4) Potassium Alum Ammonia Ammonium (Ion) Ammonium Chloride Ammonium Hydroxide Ammonium Sulfate Al2(SO4)3K2SO2 24H2O 948.8 NH3 17.0 NH4 18.0 NH4Cl 53.5 NH4OH 35.1 (NH4) 2SO4 132.2 Barium Barium Carbonate Barium Chloride Barium Hydroxide Barium Oxide Barium Sulfate Ba BaCO3 BaCl2 2H2O Ba(OH)2 BaO BaSO4 Calcium Calcium Bicarbonate Calcium Carbonate Calcium Chloride Calcium Hydrate Calcium Hypochlorite Calcium Oxide Calcium Sulfate Calcium Sulfate Calcium Nitrate Calcium Phosphate Ca Ca(HCO3)2 CaCO3 CaCl2 Ca(OH)2 Ca(ClO)2 CaO CaSO4 (anhydrous) CaSO4 2H2O (gypsum) Ca(NO3)2 Ca3(PO4)2 Carbon Chlorine (Ion) Multiplying Factor Considering Molecular Wt. of CaCO3 as 100 Substance CaCO3 to CaCO3 equivalent equivalent to substance 5.56 1.13 0.62 0.45 0.88 1.92 0.18 0.89 1.61 2.22 1.14 0.52 17.0 27.3 2.94 1.83 0.34 0.55 151.1 0.33 3.02 156.1 17.0 18.0 53.5 35.1 66.1 0.82 2.94 2.78 0.94 1.43 0.76 3.12 0.34 0.36 1.07 0.70 1.32 137.4 197.4 244.3 171.4 153.4 233.4 68.7 98.7 122.2 85.7 76.7 116.7 0.73 0.51 0.41 0.59 0.65 0.43 1.37 1.97 2.44 1.71 1.53 2.33 40.1 162.1 100.08 111.0 74.1 143.1 56.1 136.1 172.2 164.1 310.3 20.0 81.1 50.1 55.5 37.1 35.8 28.0 68.1 86.1 82.1 51.7 2.50 0.62 1.00 0.90 1.35 0.70 1.79 0.74 0.58 0.61 0.97 0.40 1.62 1.00 1.11 0.74 1.43 0.56 1.36 1.72 1.64 1.03 C 12.0 3.0 16.67 0.06 Cl 35.5 35.5 1.41 0.71 63.6 160.0 250.0 31.8 80.0 125.0 1.57 0.63 0.40 0.64 1.60 2.50 Copper (Cupric) Cu Copper Sulfate (Cupric) CuSO4 Copper Sulfate (Cupric) CuSO4 5H2O Atomic or Molecular Weight Equivalent Weight Substance Formula Iron (Ferrous) Iron (Ferric) Ferrous Carbonate Ferrous Hydroxide Ferrous Oxide Ferrous Sulfate Ferrous Sulfate Ferrous Sulfate Fe’’ Fe’’’ FeCO3 Fe (OH)2 FeO FeSO4 (anhydrous) FeSO4 7H2O FeSO4 (anhydrous) Substance CaCO3 to CaCO3 equivalent equivalent to substance Ferric Chloride Ferric Chloride Ferric Hydroxide Ferric Oxide Ferric Sulfate (Ferrisul) Ferrous or Ferric FeCl3 FeCl3 6H2O Fe (OH)3 Fe2O3 Fe2 (SO4)3 Fe or Fe Fluorine F Hydrogen (Ion) H Iodine I 127.0 127.0 0.40 2.54 Lead Pb 207.0 103.5 0.48 2.08 Magnesium Magnesium Oxide Magnesium Bicarbonate Magnesium Carbonate Magnesium Chloride Magnesium Chloride (Hexahydrate) Magnesium Hydrate Magnesium Nitrate Magnesium Phosphate Magnesium Sulfate Magnesium Sulfate (Epsom Salt) Manganese (Manganous) Manganese (Manganic) Manganese Chloride Manganese Dioxide Manganese Hydrate Manganic Oxide Manganous Oxide Mg MgO Mg (HCO3)2 MgCO3 MgCl2 24.3 40.3 146.3 84.3 95.3 12.2 20.2 73.2 42.2 47.7 4.12 2.48 0.68 1.19 1.05 0.24 0.40 1.46 0.84 0.95 MgCl2 6H2O Mg(OH)2 Mg(NO3)2 Mg3(PO4)2 MgSO4 203.2 58.3 148.3 262.9 120.4 101.6 29.2 74.2 43.8 60.2 0.49 1.71 0.67 1.14 0.83 2.03 0.58 1.48 0.88 1.20 MgSO4 7H2O 246.4 123.2 0.406 2.46 Mn’’ Mn’’’ MnCl2 MnO2 Mn(OH)2 Mn2O3 MnO 54.9 54.9 125.8 86.9 89.0 157.8 70.9 27.5 18.3 62.9 21.7 44.4 26.3 35.5 1.82 2.73 0.80 2.30 1.13 1.90 1.41 0.55 0.37 1.26 0.43 0.89 0.53 0.71 55.8 55.8 115.8 89.9 71.8 151.9 278.0 151.9 27.9 18.6 57.9 44.9 35.9 76.0 139.0 151.9 162.3 270.3 106.8 159.6 399.9 55.8 54.1 90.1 35.6 26.6 66.7 55.8 0.93 1.08 0.56 1.80 1.41 0.71 1.88 0.53 0.75 1.33 oxidation 19.0 19.0 2.66 1.01 1.01 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Multiplying Factor Considering Molecular Wt. of CaCO3 as 100 Section Table of Contents 1.79 0.56 2.69 0.37 0.86 1.16 1.11 0.90 1.39 0.72 0.66 1.52 0.36 2.78 oxidation 50.0 0.38 0.02 239 REFERENCE TABLES Substance Formula Nitrate (Ion) NO3 Nitrogen (Valence 3) N’’’ Nitric Acid Atomic or Molecular Weight HNO3 Nitrogen (Valence 5) N’’’’’ Oxygen O K Potassium Chloride KCl Potassium Carbonate 62.0 14.0 4.7 14.0 Phosphorus (Valence 5) P’’’’’ Potassium 62.0 63.0 Phosphorus (Valence 3) P’’’ 63.0 2.8 Substance CaCO3 to CaCO3 equivalent equivalent to substance 0.81 0.79 10.8 17.9 1.24 1.26 0.093 Na2SO4 142.1 270.2 Na2S2O3 Sr 0.78 Sulfur (Valence2) S’’ 32.1 1.49 Sulfur (Valence 6) S’’’’’’ 32.1 69.1 0.72 1.38 56.1 56.1 0.88 1.12 169.9 169.9 0.29 3.40 39.1 74.6 1.28 0.67 Silica SiO2 60.1 60.1 0.83 1.2 Sodium Na 23.0 23.0 2.18 0.46 Sodium Bisulfate NaHSO4 120.1 Na2CO3 106.0 143.3 28.1 84.0 143.3 7.03 0.35 7.14 2.87 Sulfur (Valence4) Sulfur Dioxide Tin (Valence 2) 135.1 0.37 2.71 64.1 43.8 8.02 5.34 32.0 6.25 9.10 1.26 0.88 0.32 0.16 0.11 1.56 0.64 5.56 0.18 Zn’’ 65.4 32.7 HCO3 61.0 61.0 0.82 1.22 Carbon Dioxide CO2 44.0 44.0 1.14 .88 126.9 126.9 0.40 2.54 Zinc (Valence 2) ACID RADICALS Carbonate Bicarbonate H2O 18.0 CO3 1.68 104.1 104.1 0.48 2.08 Chloride 58.5 58.5 0.85 1.17 Iodide l 60.0 Cl 35.5 59.5 1.14 1.59 119.0 0.14 2.40 1.42 0.63 Sn’’ Water 0.60 0.42 32.1 SO2 84.0 120.1 87.6 S’’’’ 0.70 3.13 Strontium 138.0 71.0 16.0 0.21 0.12 0.68 0.79 4.76 8.33 1.47 63.0 10.3 6.2 34.0 126.1 31.0 Na2SO3 Substance CaCO3 to CaCO3 equivalent equivalent to substance 158.1 Na2S4O6 Sodium Sulfite Equivalent Weight Multiplying Factor Considering Molecular Wt. of CaCO3 as 100 158.1 Sodium Tetrathionate AgNO3 NaHCO3 Sodium Thiosulfate 0.16 Silver Nitrate Sodium Bicarbonate 102.0 6.25 74.6 Si’’’’ NaPO3 (69% P2O5) Sodium Sulfate KOH Silicon (Valence 4) (Hagan) Atomic or Molecular Weight 8.0 39.1 AgCl Meta-Phosphate Formula 0.056 Potassium Hydroxide Silver Chloride Substance 16.0 31.0 K2CO3 Equivalent Weight Multiplying Factor Considering Molecular Wt. of CaCO3 as 100 9.00 30.0 35.5 0.84 1.54 1.67 1.41 1.19 0.65 .60 .71 Sodium Bisulfite NaHSO3 Sodium Chloride NaCl Sodium Hypochlorite NaClO 74.5 37.3 0 .67 1.49 Nitrate NO3 62.0 62.0 0.81 1.24 Sodium Nitrate NaNO3 85.0 85.0 0.59 1.70 Phosphate PO4 95.0 31.7 1.58 0.63 NaNO2 69.0 69.0 0.73 1.38 P2O5 142.0 23.7 2.11 0.47 SO4 96.1 48.0 1.04 0.96 1.0 50.00 0.02 31.0 1.61 Sodium Carbonate Sodium Hydroxide Sodium Nitrite Sodium Oxide Tri-sodium Phosphate Tri-sodium Phosphate (anhydrous) Di-sodium Phosphate Di-sodium Phosphate (anhydrous) NaOH 40.0 Na2O 62.0 Na3PO4 12H2O (18.7% P2O5) 53.0 40.0 31.0 0.94 1.25 1.61 1.06 0.80 0.62 380.2 126.7 0.40 2.53 Na3PO4 (43.2% P2O5) 164.0 54.7 0.91 1.09 Na2HPO4 12H2O (19.8% P2O5) 358.2 119.4 0.42 2.39 Na2HPO4 (50% P2O5) 142.0 47.3 1.06 0.95 Monosodium Phosphate NaH2PO4 H2O (51.4% P2O5) 138.1 Mono-sod. (anhydrous) NaH2PO4 (59.1% P2O5) 120.0 46.0 40.0 1.09 1.25 0.92 0.80 Hydroxyl Phosphorous Oxide Sulfide (Valence 2) Sulfate Sulfur Trioxide ACIDS OH S’’ 32.1 SO3 Hydrogen H Carbonic Acid H2CO3 Acetic Acid 17.0 80.1 1.0 17.0 16.0 40.0 2.94 3.11 1.25 0.32 0.80 HC2H3O2 60.1 60.1 Hydrochloric Acid HCl 36.5 36.5 1.37 0.73 Sulfurous Acid H2SO3 82.1 41.1 1.22 0.82 Hydrogen Sulfide H2S – – – Phosphoric Acid Sulfuric Acid Manganous Acid H3PO4 62.0 98.0 H2SO4 98.1 H2MnO3 104.9 32.7 49.0 52.5 0.83 1.53 1.02 0.95 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK 0.34 Section Table of Contents 1.20 0.62 0.65 0.98 – 1.05 REFERENCE TABLES Equivalents EQUIVALENTS OF LIQUID MEASURES AND WEIGHTS (3) By s (2) Multiply Gallon Gallon s (1) To Obtain s Imperial Gallon 1 0.833 0.125 0.1041 7.48052 6.22888 0.2641779 0.2199756 Imperial Gallon 1.2009 Pint Pound Water* 1 0.11995 Cubic Foot Cubic Inch Cubic Meter 264.170 s (3) By 1 0.0069445 14.696 14.2233 0.001422 0.036092 0.432781 0.491154 0.0193368 14.5038 145.038 144 1 2116.22 2048.155 0.204768 5.1972 62.3205 70.7262 2.78450 2088.55 20885.5 0.13368 1 1.042 59.8442 62.365 10 1 0.03609 219.969 2113.34 2202 s (2) Multiply 8.337 0.034632 2.113423 pound/in2 pound/ft2 Atmospheres 0.068046 0.000473 1 0.96784 0.0000968 .002454 0.029449 0.033421 0.0013158 0.98692 9.8692 2.202 kg/cm2 kg/m2 0.070307 0.000488 1.0332 1 0.0001 0.00253 0.03043 0.03453 0.0013595 1.01972 10.1972 703.070 4.8241 10332.27 10000 1 25.375 304.275 345.316 13.59509 10197.2 101972.0 inch water (68°F) 27.7276 0.1926 407.484 394.38 0.3944 1 12 13.6185 0.53616 402.156 4021.56 *Water at 68°F (20°C) Mercury at 32°F (0°C) **MPa (megapascal) = 10 bar = 1,000,000 N/m2 (newton/meter2) EQUIVALENTS OF FLOW RATE (3) By s gpm. . . . . . . . . . . . . . . . . . . gpd . . . . . . . . . . . . . . . . . . . lpm . . . . . . . . . . . . . . . . . . . m3/hr . . . . . . . . . . . . . . . . . . ft3/min . . . . . . . . . . . . . . . . . pound/min . . . . . . . . . . . . . . gpm s (2) Multiply s (1) To Obtain 1. . . . . . . . 0.000694. . . . . . . . 0.2642. . . . . . . . 4.403. . . . . . . . 7.48. . . . . . . . 0.1199. . . . . . . . Cubic Foot 8 0.00361 EQUIVALENTS OF PRESSURE AND HEAD pound/in2 pound/ft2 Atmospheres kg/cm2 kg/m6 inch water* foot water* inch mercury** mm mercury** bar** MPa** Pound Water* 0.9596 *Water at 60°F (15.6°C) 1 Barrel = 42 gallons (petroleum measure) (1) To Obtain Pint 9.60752 0.1 0.004329 Liter s 240 gpd 1440. . . . . . . . 1. . . . . . . . 380. . . . . . . . 6370. . . . . . . . 10771.2. . . . . . . . 172.72. . . . . . . . Cubic Inch Liter Cubic Meter 231 3.78533 0.003785 0.01671 28.875 0.473166 0.000473 1 1728 2831702 0.028317 0.16054 277.42 0.016035 4.54596 27.708 0.0005787 0.0353154 0.45405 0.016387 0.0000164 61023.38 999.972 1 1 foot water inch mercury mm mercury (68°F) (32°F)* (32°F)* 2.3106 0.01606 33.9570 32.8650 0.003287 0.08333 1 1.1349 0.044680 33.5130 335.130 2.03602 0.014139 299.921 28.959 0.002896 0.073430 0.88115 1 0.03937 29.5300 295.300 lpm m3/hr 3.785. . . . . . . . 0.00263. . . . . . . . 1. . . . . . . . 16.67. . . . . . . . 28.3. . . . . . . . 0.454. . . . . . . . 0.2271. . . . . . . . . 0.000158. . . . . . . . . 0.06. . . . . . . . . 1. . . . . . . . . 1.7. . . . . . . . . 0.2724. . . . . . . . . 51.7150 0.35913 760 735.559 0.073556 1.8651 22.3813 25.40005 1 750.062 7500.62 0.001000 bar** megapascal (MPa)** 0.06895 0.000479 1.01325 0.98067 0.000098 0.00249 0.029839 0.033864 0.001333 1 10.0 ft3/min 0.1337. . . . . . . . . 9.284 x 10-5 . . . . . . . . . 0.0353. . . . . . . . . 0.588. . . . . . . . . 1. . . . . . . . . 0.00267. . . . . . . . . Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK 0.000454 1 61.02509 35.31446 0.004546 Section Table of Contents 0.006895 0.0000479 0.101325 0.098067 0.0000098 0.000249 0.0029839 0.0033864 0.0001333 0.10 1 pound/min 8.337 0.00579 2.202 36.71 3750 1 REFERENCE TABLES 241 Temperature Conversion, Tank Areas and Volume FAHRENHEIT/CENTIGRADE TEMPERATURE CONVERSION CHART °C °F 160° 320° 140° 290° 120° 260° 100° 230° 212° 80° 200° 32° 170° 60° 140° 40° 20° 110° 80° TANK AREAS AND VOLUMES* Nominal Diameter 12” . . . . . . . . . . . . . . . . . . 14” . . . . . . . . . . . . . . . . . . 16” . . . . . . . . . . . . . . . . . . 18” . . . . . . . . . . . . . . . . . . 20” . . . . . . . . . . . . . . . . . . 24” . . . . . . . . . . . . . . . . . . 30” . . . . . . . . . . . . . . . . . . 36” . . . . . . . . . . . . . . . . . . 42” . . . . . . . . . . . . . . . . . . 48” . . . . . . . . . . . . . . . . . . 54” . . . . . . . . . . . . . . . . . . 60” . . . . . . . . . . . . . . . . . . 66” . . . . . . . . . . . . . . . . . . 72” . . . . . . . . . . . . . . . . . . 78” . . . . . . . . . . . . . . . . . . 84” . . . . . . . . . . . . . . . . . . 90” . . . . . . . . . . . . . . . . . . 96” . . . . . . . . . . . . . . . . . . 102” . . . . . . . . . . . . . . . . . 108” . . . . . . . . . . . . . . . . . 114” . . . . . . . . . . . . . . . . . 120” . . . . . . . . . . . . . . . . . 126” . . . . . . . . . . . . . . . . . 132” . . . . . . . . . . . . . . . . . Area = sq. ft. or cu. ft. per ft. of depth Unlined Lined 0.785 . . . . . . . . . . . . 1.069 . . . . . . . . . . . . 1.396 . . . . . . . . . . . . 1.767 . . . . . . . . . . . . 2.182 . . . . . . . . . . . . 3.142 . . . . . . . . . . . . 4.784 . . . . . . . . . . . . 6.918 . . . . . . . . . . . . 9.444 . . . . . . . . . . . . 12.36 . . . . . . . . . . . . . 15.67 . . . . . . . . . . . . . 19.37 . . . . . . . . . . . . . 23.47 . . . . . . . . . . . . . 27.96 . . . . . . . . . . . . . 32.84 . . . . . . . . . . . . . 38.0 . . . . . . . . . . . . . . 43.67 . . . . . . . . . . . . . 49.71 . . . . . . . . . . . . . 56.15 . . . . . . . . . . . . . 62.99 . . . . . . . . . . . . . 70.07 . . . . . . . . . . . . . 77.68 . . . . . . . . . . . . . 85.68 . . . . . . . . . . . . . 94.07 . . . . . . . . . . . . . 0.765 . . . . . . . . . . . . 1.049 . . . . . . . . . . . . 1.372 . . . . . . . . . . . . 1.748 . . . . . . . . . . . . 2.157 . . . . . . . . . . . . 3.104 . . . . . . . . . . . . 4.703 . . . . . . . . . . . . 6.821 . . . . . . . . . . . . 9.33 . . . . . . . . . . . . . 12.24 . . . . . . . . . . . . . 15.53 . . . . . . . . . . . . . 19.22 . . . . . . . . . . . . . 23.30 . . . . . . . . . . . . . 27.77 . . . . . . . . . . . . . 32.63 . . . . . . . . . . . . . 37.77 . . . . . . . . . . . . . 43.42 . . . . . . . . . . . . . 49.45 . . . . . . . . . . . . . 55.8 . . . . . . . . . . . . . . 62.70 . . . . . . . . . . . . . 69.91 . . . . . . . . . . . . . 77.51 . . . . . . . . . . . . . 85.51 . . . . . . . . . . . . . 93.89 . . . . . . . . . . . . . 0° 50° -20° 20° -40° -10° -40° U.S. Gallons per ft of depth Unlined Lined 5.87. . . . . . . . . . . 8.0. . . . . . . . . . . . 10.44. . . . . . . . . . . 13.22. . . . . . . . . . . 16.32. . . . . . . . . . . 23.50. . . . . . . . . . . 35.8. . . . . . . . . . . . 51.8. . . . . . . . . . . . 70.6. . . . . . . . . . . . 92.5. . . . . . . . . . . . 117.0. . . . . . . . . . . . 145.0. . . . . . . . . . . . 176.0. . . . . . . . . . . . 209.0. . . . . . . . . . . . 246.0. . . . . . . . . . . . 284.0. . . . . . . . . . . . 327.0. . . . . . . . . . . . 372.0. . . . . . . . . . . . 420.0. . . . . . . . . . . . 471.0. . . . . . . . . . . . 524.0. . . . . . . . . . . . 581.0. . . . . . . . . . . . 641.0. . . . . . . . . . . . 704.0. . . . . . . . . . . . *These figures are actual values that have been corrected for shell thickness and true inside diameter measurements. Lining is 3/23" up to 60"; 1/8" above 60". 5.73 7.86 10.27 13.09 16.12 23.20 35.2 51.0 69.8 91.6 116.0 144.0 174.0 208.0 244.0 283.0 325.0 370.0 418.0 469.0 523.0 580.0 640.0 702.0 Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 242 REFERENCE TABLES Relative Size of Particles A KEY TO THE RELATIVE SIZES OF PARTICLES Carbon Black Jewelers Rouge Tobacco Smoke Beach Sand Clouds/Fog Virus Drizzle Bacteria Colloidal Suspended Matter Electron Microscopy Pleuro-Pneumonia-Like Organisms Pollens Lung-Damaging Dust Microfiltration Ultrafiltration Mist Macrofiltration Micrometers µm Section Table of Contents Sewing Needle Diameter Razer Blade Thickness Human Hair Diameter Flour Smallest Visible Particle BACK 1000 800 600 400 200 100 80 60 Ragweed Pollen Aluminum Foil 40 20 Red Blood Cell Yeasts and Fungi Pseudomonas Cepacia Organism Serratia Marcescens Organism Pseudomonas Diminuta Organism Polio Virus 10 8 6 4 2 1.0 0.88 0.6 0.4 0.2 0.1 0.08 0.04 0.04 0.02 0.01 0.008 0.006 0.004 0.002 0.001 Siemens Water Technologies 24-hr Customer Service: 800.466.7873 243 REFERENCE TABLES Velocity of Liquids in Pipes VELOCITY OF LIQUIDS IN PIPE The mean velocity of any flowing liquid can be calculated from the following formula, or from the nomograph to the right. The nomograph is a graphical solution of the formula. n = 183.3 q/d2 = 0.408 Q/d = 0.0509 W/d2ρ (where d2 is the square of the inside diameter of commercial wrought steel pipe) The pressure drop per 100 feet and the velocity in schedule 40 pipe, for water at 60°F, have been calculated for commonly used flow rates for pipe sizes of 1/8 to 24 inch. W Q q d ρ ν Example Given: Maximum flow rate of a liquid will be 300 gpm with maximum velocity limited to 12 feet per second through Schedule 40 pipe. Find: The smallest pipe size and the velocity through the pipe. Solution: Connect 1. Q = 300 v = 12 2. 3 " Schedule 40 pipe suitable 3. Q = 300 3" Sched 40 Read d = 2.75 ν = 10 Reasonable Velocities for the Flow of Water through Pipe Service Condition Reasonable Velocity Boiler Feed . . . . . . . . . . . . . . . . . . . . . . . . . 8 to 15 ft per second Pump suction and drain lines . . . . . . . . . . . . 4 to 7 ft per second General Service . . . . . . . . . . . . . . . . . . . . . 4 to 10 ft per second City . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to 7 ft per second Information contained here was obtained from “Flow of Fluids through Valves, Fittings and Pipe”, Copyright 1969 Crane Co. BACK Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents This page intentionally left blank Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Main Table of Contents Index and Glossary TA B L E O F CONTENTS BACK GLOSSARY OF KEY TERMS.................................................................246 TRADEMARK STATEMENT ...................................................................253 Main Table of Contents 245 246 GLOSSARY The following is a glossary of frequently used water treatment terms. A ABSOLUTE: A degree of filtration, usually referring to 99.9999% removal of particulates greater than a stated size. BACKWASH: The process in which beds of filter or ion exchange media are subjected to flow in the opposite direction from the service flow to loosen the bed and flush out suspended matter. BACTERIA: Unicellular microorganisms that typically reproduce by cell division. May or may not be harmful to humans. ACID: A substance that releases hydrogen ions when dissolved in water. Most acids will dissolve common metals, and will react with a base to form a neutral salt and water. A chemical used to regenerate cation ion exchange resin. BASE: A substance that releases hydroxyl ions when dissolved in water. Bases react with acids to form a neutral salt and water. ACIDITY: An expression of the concentration of hydrogen ions present in a solution. BED DEPTH: The depth of the filter medium or ion exchange resin in a vessel. ACTIVATED CARBON: Carbon activated by high temperature steam or carbon dioxide to form a material of high adsorptive capacity. A porous material available in powdered or granular form, activated carbon is used primarily for the removal of chlorine and chloramines or dissolved organic matter. BED EXPANSION: The effect produced during backwashing: the resin particles become separated and rise in the column. This expansion of the bed, caused by the increase in the space between the resin particles, may be controlled by regulating backwash flow. ALKALINITY: In natural water, alkalinity results from the presence of CO2, bicarbonate, carbonate, and hydroxide components. The alkalinity test measures the quantity of alkaline materials in water, whereas, the pH test indicates whether a water sample is acidic or basic. BOD (BIOCHEMICAL OXYGEN DEMAND): The amount of oxygen utilized by natural agencies in stabilizing organic matter at specified test conditions. ALUM: Aluminum sulfate [Al(SO4)3 • 18 H2O], widely used for flocculation of contaminants in municipal water treatment, typically for the removal of color and turbidity. ANION: A negatively charged ion. BRACKISH WATER: Water containing dissolved solids in the range of 1,000 to 10,000 mg/L. BRINE: A solution of sodium chloride (salt) used for regenerating water softeners. A mixed sodium, calcium and magnesium chloride solution is the resulting waste solution from regeneration. ANTHRACITE: A granular, hard coal, used sometimes as a sand filter media. In an activated form, anthracite is commonly used for organic and chlorine removal (activated carbon) from water. BRINE SEAL: A rubber lip on the outside of a spiral wound RO cartridge that prevents feed bypass between the cartridge and the inside pressure vessel wall. ANTI-TELESCOPING DEVICE (ATD): A plastic cover that looks like a wheel with spokes, and is attached to the ends of a spiral wound RO cartridge to prevent distortion of the cartridge leaves caused by high flows. BRINE STREAM: The reject stream from an RO cartridge. Portion of the feed stream that does not pass through the membrane. AVERAGE TRANSMEMBRANE PRESSURE: Average transmembrane pressure is the actual net driving force of water within a UF or RO module. It is determined as follows: 200 psi = RO feed pressure +190 psi = RO reject pressure 390 ÷2 = 195 195 = average transmembrane pressure (assuming the permeate pressure is 0) B BACKFLOW: Flow of water in a pipe or line in a direction opposite to the normal flow. Often associated with the flow of possibly contaminated water into a potable water system. BUBBLE POINT TEST: Used to test the integrity of 0.22 and 0.45 micron microporous filters. BUFFER: A chemical that causes a solution to resist changes in pH, or to shift the pH to a specific value. C CALCIUM CARBONATE EQUIVALENT: A common basis for expressing the concentration of hardness and other salts in chemically equivalent terms to simplify certain calculations. Signifies that the concentration of a dissolved mineral is chemically equivalent to the stated concentration of calcium carbonate. CAPACITY: The absorption ability possessed per unit of resin volume or per unit of weight (i.e., the potential for exchange). For water softeners, the capacity is expressed in grains of Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents GLOSSARY hardness removal between regenerations, and is related to the pounds of salt used in regeneration. CAPACITY CURVE: A graph of capacity vs. regenerant levels for an ion exchange unit or system. CATION: A positively charged ion. CAUSTIC: Any substance that releases hydroxide ions when dissolved in water. A chemical used to regenerate anion ion exchange resin. CAVITATION: Caused by pump starvation, cavitation is a crackling noise caused by bubbles imploding on the tip of impellers inside the pump. CHANNELING: The flow of water or other solution in a limited number of passages in a filter or ion exchange bed, instead of distributed flow through all the passages in the bed. May be caused by fouling of the bed and plugging of many passages, poor distributor design, flow rates that are too low, or faulty operational procedures. CHEMICAL FEEDER: A mechanical device designed to introduce chemicals into a water system in proportion to water flow. CHEVRON SEAL: A rubber lip on the outside of a spiral wound RO cartridge that prevents feed bypass between the cartridge and the inside pressure vessel wall. CHLORAMINES: Compounds formed when chlorine and ammonia are mixed in water. Used to kill bacteria in water, chloramines can be inadvertently formed in chlorinated water supplies that contain nitrogenous impurities. If present in water used for dialysate preparation, chloramines can cause illness (particularly anemia) in dialyzing patients. Can be removed by activated carbon. Chloramine level can be determined by subtracting the free chlorine level from the total chlorine level. CHLORINATION: The process of water treatment whereby a chlorine gas or liquid solution is injected into a water supply to control microorganisms. The feed, demand and residual chlorine are expressed as ppm. CHLORINE DEMAND: A measure of the amount of chlorine that will be consumed by organic matter and other oxidizable substances in a water before a chlorine residual will be found. The difference between the total chlorine fed and the chlorine residual. CHLORINE, FREE AVAILABLE: The hypochlorite ions (OCI - ), hypochlorous acid (HOCl) or the combination thereof present in water. CLARIFIER: A tank in which precipitate settles. COAGULANT: A material, such as alum, which will form a gelatinous precipitate in water, and cause the agglomeration of finely divided particles into larger particles which can be removed by settling and/or filtration. BACK 247 COD (CHEMICAL OXYGEN DEMAND): The amount of oxygen required under specified test conditions for the oxidation of water borned organic and inorganic matter. COLIFORM BACTERIA: A group of organisms primarily found in human and animal intestines and wastes, and thus widely used as indicator organisms to show the presence of such wastes in water, and the possible presence of disease-producing bacteria. COLLOID: A substance of very fine particle size, typically between 0.1 and 0.001 microns in diameter suspended in liquid or dispersed in gas. A system of at least two phases, including a continuous liquid plus solid, liquid or gaseous particles so small that they remain in dispersion for a practicable time. COLLOIDAL DENSITY INDEX: A test used to verify the performance of point-of-use ultrafiltration systems. The test, which is very similar to silt density index (SDI), is used to measure colloidal concentration upstream and downstream of the system. It is assumed that the feedwater to the system will be of very high quality, rendering the SDI test invalid. COLONY-FORMING UNITS (CFU): Unit used in the measure of total bacteria count. COLOR: Dissolved or suspended matter causing discoloration of the water. Expressed as alpha units. COMPACTION: The tightening of a membrane structure due to compressive stress of operating pressure. CONCENTRATION POLARIZATION: The phenomenon that occurs when material retained by the membrane builds up on the membrane surface and forms a boundary layer immediately adjacent to the membrane surface. Over time, this layer causes a decrease in flux. CONDUCTIVITY: The electrical measurement of the water’s ability to pass electric current. It is dependent on temperature and total concentration of ionized substances in solution. The lower the level of ionized substances, the lower the conductivity. Conductivity is inverse of resistivity and is measured in microsiemens/cm. CONTINUOUS ELECTRODEIONIZATION (CEDI): A process that uses ion exchange membranes, ion exchange resins and electricity to produce consistent high-purity water without the need for chemical regeneration. CEDI removes dissolved, ionizable materials such as dissolved silica, carbon dioxide and some organics. CONVERSION: The percentage of feed water that ends up as the product, or permeate. Also known as recovery. CROSSFLOW MEMBRANE FILTRATION: A separation of the components of a fluid by semipermeable membranes through the application of pressure and tangential flow to the membrane surface. Includes the processes of reverse osmosis, ultrafiltration, nanofiltration, and microfiltration. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 Section Table of Contents 248 GLOSSARY D DECARBONATOR: A device to remove carbon dioxide from water. DECAT WATER: Water that has an absence of cations. Usually produced by a cation resin regenerated with acid. DEGASIFICATION: The process of removing dissolved gasses in water. DEIONIZATION: The removal of all ionized minerals and salts (both organic and inorganic) from a solution by ion exchange. Positively charges ions are removed by a cation exchange resin in exchange for a chemically equivalent amount of hydrogen ions. Negatively charged ions are removed by anion exchange resin for a chemically equivalent amount of hydroxide ions. The hydrogen and hydroxide ions introduced in this process unite to form water molecules. The term is often used interchangeably with demineralization. DEMINERALIZATION: The process of removing minerals from water, usually through deionization, reverse osmosis, or distillation. DEPTH FILTER: A filter of compacted sand, or diatomaceous earth; sintered metal or glass; spool wound cotton fiber; or compressed, matted fibers. Particles are retained in and on any or all of the above by random adsorption or entrapment within the matrix of the filters. Efficiency of depth filters are rated in nominal terms. DIALYSATE: The solution used in an artificial kidney machine to remove excess fluids and metabolic end products from the blood. DIALYSIS: The separation of components of a solution by diffusion through a semi-permeable membrane which is capable of passing certain ions or molecules while rejecting others. DIATOMACEOUS EARTH: A powder-like filter media made from crushed diatoms capable of submicron particle removal. DIFFERENTIAL PRESSURE: The difference in pressure between two given points in a water system. May be due to differences in elevation, or to friction losses or pressure drops due to resistance to flow in pipes, softeners, filters or other devices. DISINFECTION: The process of killing disease-producing bacteria. DISSOLVED IRON: In water conditioning, iron is usually described as being dissolved or undissolved. The dissolved or ferrous iron is ver y soluble in mos t water, and the undissolved ferric iron is almost always insoluble. DISSOLVED SOLIDS: The residual material remaining after filtering the suspended material from water and evaporating the solution to a dry state. DISTILLATION: The process in which a liquid, such as water, is converted into its vapor state by heating, and the vapor cooled and condensed to the liquid state and collected. Used to remove solids and other impurities from water. DISTRIBUTOR: Used within softener or DI tank to distribute the flow of water throughout the tank and to prevent resin from escaping the vessel. Sometimes called a strainer. E E. COLI: Escherichia coli, one of the members of the coliform group of bacteria associated with animal and human waste. Normally used by health departments to rule on the purity of a drinking water supply. EFFLUENT: The water emerging from a treatment unit, system or process, such as the product from an ion exchange unit. ELECTRODEIONIZATION: A process that removes ionizable species from liquids using an electrically active media and an electrical potential to influence ion transport. ELECTROLYTE: A chemical compound that dissociates or ionizes in water to produce a solution that will conduct an electrical current; an acid, base, or salt. ELEMENT: Usually another term for filter or cartridge. EXHAUSTION: The state in which resin is no longer capable of useful ion exchange. The depletion of the exchanger’s supply of available ions. The exhaustion point is determined in terms of a). a value in parts per million of ions in the effluent solution, b). the reduction in quality of the effluent water determined by a conductivity bridge which measures the electrical resistance of the water. F FEED: Raw or untreated water entering a water purification system or ion exchange system for further treatment or “polishing”. FILTRATE: Also called permeate or product, filtrate is the purified portion of a solution that passes through a membrane. FINES: Extremely small particles of filter media or ion exchange material, formed either in the manufacturing process or as a result of breakdown. Undesirable in most systems because of high pressure drop. FLOCCULATION: The agglomeration of finely divided suspended solids into larger, usually gelatinous, par ticles. The development of a “floc” after treatment with a coagulant by gentle stirring or mixing. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 249 GLOSSARY FLUX: The rate of fluid passage through a given area of membrane per unit of time. Usually expressed in gallons per square foot per day (gfd). HIGH-PURITY WATER: Highly treated water with attention to microbiological, particle, organics and mineral reduction or elimination. FORMALIN: A clear, aqueous solution of formaldehyde and a small amount of methanol, used as a sanitant. I FORWARD AIR FLOW TEST: Also called “diffusion test” and “integrity test”, the forward air flow test is a measurement of the volume of gas which will pass through a membrane at a given pressure. Used to detect any flaws in the integrity of membranes or seals. In critical applications, this test should be performed prior to each process run. FOULING: The rapid reduction in flux, caused by the build-up of retained material on the membrane surface. The process in which undesirable foreign matter accumulates in a bed of filter media or ion exchanger, clogging pores and coating surfaces and thus preventing proper operation of the bed. Typical symptoms of fouling are: a decrease in rated product flow (flux), a decrease in percent salt rejection (RO membrane only), a rapid increase of feed vs. reject differential pressure. FOULING INDEX: Used synonymously with the terms “pluggage test” and “silt density index”. A test used to determine the concentration of colloids and particles in water fed to RO or UF systems. The test results can be used to determine the effectiveness of pretreatment systems and/or the need for pretreatment. Silt density index is also the best method to predict fouling characteristics caused by undissolved contaminants. G GRAINS CAPACITY: The amount of minerals that will be removed by a specific quantity of resin. GRAM NEGATIVE BACTERIA: A type of bacteria capable of surviving and multiplying in all types of waters, even those treated by reverse osmosis, deionization, softeners, and distillation. Dead gram negative bacteria contain bacterial endotoxin, or pyrogens, that cause a fever when injected into the bloodstream. GREENSAND: A mineral (glauconite), used as a filtration medium. H HARDNESS: The solution of calcium and magnesium as cations independent of the nature of anions present. Generally expressed in terms of calcium carbonate. HARDNESS LEAKAGE: The presence of hardness minerals (calcium and magnesium) after water has passed through the softener. Hardness leakage is caused primarily by resin bed channeling, due to improper backwashing, the existence of algae, or a combination of a high service flow with a high hardness content. INFLUENT: The water entering a treatment unit, system or process, such as the feed entering an ion exchange unit. ION EXCHANGE: A process in which certain ions of a given charge may be absorbed from solution and replaced in the solution by different ions of a similar charge from the resin. L LAL: Abbreviation for Limulus Amebocyte Lysate, a reagent used to detect endotoxins (pyrogens) in a water supply. LANGELIER SATURATION INDEX: A measure of the probability of whether water will precipitate or dissolve calcium carbonate, which forms scaling on the walls of pipes and RO membranes. The index is calculated from the total calcium, alkalinity, pH, temperature, and total dissolved solids of the water. A positive index indicates scaling tendencies, while a negative index indicates that scaling will not occur. LEAKAGE: The phenomenon in which some of the influent ions are not removed and appear in the effluent of an ion exchange system. Leakage may be caused by incomplete regeneration, excessive flow rates, low temperatures, the concentration or characteristics of the influent ions. LIME SCALE: Hard water scale containing a high percentage of calcium carbonate. M MACRORETICULAR: A term used to describe resins that have a rigid polymer porous network in which there exists a true pore structure even after drying. The pores are larger than atomic distances and are not part of the gel structure. MANGANESE GREENSAND: A manganese-coated greensand used as a filter medium for removal of manganese and iron. MEGOHM: One million ohms. Usually used as a measure of water purity, on resistivity in megohm-cm. MEMBRANE: Media through which a liquid is passed. The term is usually used to define the functional filter material, and not its supporting substrate, screens or other cartridge components. The word membrane is often used synonymously with filter or cartridge. MESH: The number of openings in a lineal inch of wire cloth. MHO: A measure of conductance, reciprocal of ohms. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents 250 GLOSSARY MICROFILTRATION: Filtration designed to remove particles and bacterial in the approximate range of 0.05 to 10 micrometers. MICROMHO (MICROSIEMENS): One millionth of a Mho. Unit of measurement for conductivity (equivalent to the inverse of 1 million ohms of resistivity). Water quality is measured by its conductivity in micromhos per centimeter. The higher the quality the lower the micromho reading. MICRON (MICROMETERS): A metric unit of measurement equivalent to 10-6 meters, 10-4 centimeters. System is η. MICROPOROUS FILTRATION: Often used synonymously with the terms “absolute filtration” and occasionally “screen filtration”, microporous filters (or devices) have absolute ratings and will “absolutely” remove contaminants larger than their rated pore size, except for some types of bacteria that can “grow through” the filter. MIXED BED ION EXCHANGE: A demineralization process where the anion and cation ion exchange resins are mixed in the same vessel. N NANOFILTRATION (NF): A crossflow membrane separation process which removes particles in the 300 to 1000 molecular weight range, selected salts and most organics. NEGATIVE PRESSURE: A pressure below that of the surrounding atmospheric pressure at a specific point; a partial vacuum. NEUTRALIZATION: The addition of either an acid or a base to a solution as required to produce a neutral solution. The use of alkaline or basic materials to neutralize the acidity of some waters is a common practice in water conditioning. O OPERATING PRESSURE: The range of pressure, usually expressed in pounds per square inch, over which a water system is designed to function. ORGANIC MATTER: Substances derived from plant or animal matter, as opposed to inorganic matter derived from rocks and minerals. Organic matter is characterized by its carbon-hydrogen structure. OSMOSIS: The diffusion of a solvent through a semi-permeable membrane from a less concentrated solution to a more concentrated solution. OSMOTIC PRESSURE: The pressure required to prevent spontaneous flow of water into a solution separated by a semipermeable membrane. OXIDATION: A chemical process in which electrons are removed from an atom, ion or compound. The addition of oxygen is a specific form of oxidation. Combustion is an extremely rapid for of oxidation, while the rusting of iron is a slow form. OXIDIZING FILTERS: Filters that remove both iron and manganese from the water. The units, also called iron removal filters, contain a filter medium that has the ability of oxidizing and absorbing dissolved iron and manganese. The filter is regenerated with potassium permanganate and cleaned with backwashing. An oxidizing filter can also consist of a tank where iron is oxidized with air and the deposit is collected in a sand filter. OZONE: An unstable form of oxygen (O3) that can be generated by an electrical discharge through air or oxygen. A strong oxidizing agent, ozone can be used to disinfect water systems. P pH: An expression of the acidity of a solution. The negative logarithm of the hydrogen ion concentration. A pH of 1 is very acidic; pH 7 is neutral; pH 14 is very basic. PARTS PER MILLION: A measure of concentration. One part per million of water is equivalent to 1 mg/liter of liquid. This is also equivalent to 0.0584 grains/U.S. gallon. 17.1 ppm is equal to 1 grain per gallon. PERACETIC ACID: A clear, colorless liquid with a pungent odor, composed of hydrogen peroxide and acetic acid. Can be used to sanitize water systems and cartridges. PERMEATE: The portion of the feed stream that passes through the membrane and emerges as purified water. PERMEATOR: A name for an RO element or module. The unit that contains the semi-permeable membrane, and is constructed to allow the purified water to pass through the membrane, under pressure, while leaving behind the reject portion. PLUGGAGE TEST: Used synonymously with the terms “fouling index” and “silt density index”. A test used to determine the concentration of colloids and particles in tap water fed to an RO or UF system. The test results can be used to determine the effectiveness of pretreatment systems and/or the need for pretreatment. Silt density index is also the best method to predict fouling characteristics caused by undissolved contaminants. POLISHING: Additional purification by RO, ion exchange, etc., to produce exceptionally pure water. POTABLE WATER: Water that is suitable for human consumption. PRESSURE DIFFERENTIAL: The difference in pressure between two points in a system caused by differences in elevation and/or pressure drop due to flow. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents 251 GLOSSARY PRODUCT: The treated (filtered, deionized, etc.) water from a water purification system. SAND FILTER: Packed bed of sand that can remove particles down to 25 microns. Can be regenerated by backwashing. PYROGEN: A substance or agent that, when introduced into the blood stream of man or warm-blooded animals, produces fever. Endotoxins produced from gram negative bacteria fall under this definition. Pyrogens can be removed by RO and UF membranes. SANITIZE: A process performed to reduce the number of bacteria. R RATED CAPACITY: The basis for calculating the period of time, or number of gallons delivered by a water softener, deionizer or filter, between regenerations or servicing, as determined under specific test conditions. RAW WATER: Untreated water from wells or from surface sources. RECOVERY: Expressed in percent, recovery is the portion of the RO feed water that is converted to product. Percent recovery is calculated as follows: Product Flow X 100 = Percent Recovery Feed Flow REGENERATION: The chemical restoration of cation and anion resins by treatment with acid and caustic respectively. REJECT: The portion of the feed stream that does not pass through the membrane to become permeate (purified), but is retained by the membrane, and eventually passes to drain. This water contains the bulk of the dissolved matter along with particulates and microorganisms. Reject is used synonymously with the terms concentrate, brine, retentate and waste. REJECT DELTA P: The pressure differential between the membrane feed pressure and reject pressure. RESISTIVITY (OF WATER): The electrical measurement of the water’s ability to resist the flow of electric current, and is dependent on the temperature and total concentration of the ionized substances in solution. The lower the level of ionized substances, the higher the resistivity. Resistivity is the inverse of conductivity, and is measured in megohms per centimeter. REVERSE OSMOSIS (RO): The process by which a solution under pressure (in excess of osmotic pressure) is forced through a semipermeable membrane from a more concentrated to a less concentrated solution. S SALT PASSAGE: Expressed in percent, salt passage is the ratio of salt concentration in the product water to salt concentration in the RO feed water. SALT REJECTION: Expressed in percent, salt rejection is the salt concentration rejected by the RO membrane. Percent salt rejection is calculated as follows: % Salt Rejection = Conductivity of Feed - Conductivity of Permeate X 100 Conductivity of Feed SCALE: The precipitate of sparingly soluble salts that forms on surfaces in contact with water as a result of physical or chemical change. SEMI-PERMEABLE MEMBRANE: Usually a thin, membrane that will allow the passage of some ions or materials while preventing the passage of others. SEPARATE BED ION EXCHANGE: A demineralization process where the anion and cation exchange resins are in separate vessels, as opposed to mixed bed ion exchange, where the anion and cation resins are in the same vessel. SEPARATION: The dividing of two or more types of resin by specific gravity. Usually achieved by backwashing at a specified flow. SILT DENSITY INDEX: A test used to determine the concentration of colloids and particles in water fed to an RO or UF system. The test results can be used to determine the effectiveness of pretreatment systems and/or the need for pretreatment systems. Silt density index is also the best method to predict fouling characteristics caused by undissolved contaminants (fouling index). SINGLE PASS: Refers to a single-pass RO system in which a portion of the feed water to the system will pass one time through an RO membrane to be purified. SOFTENER: Ion-exchange device that removes hardness from water by exchanging calcium and magnesium in the water for sodium ions. The softener is regenerated with sodium chloride, and the calcium and magnesium salts are rinsed to drain. SOFT WATER: Any water that contains less than 1.0 gpg (17.1 mg/L) of hardness minerals, expressed as calcium carbonate. SPIRAL WOUND RO CARTRIDGE: A cartridge that is constructed with a sheet of open-structured support material “sandwiched” between two sheets of RO membrane, wound spirally around a perforated, PVC core. As the untreated water (feed) flows through the support material, purified water permeates the layers of the membrane into the core, where is is extracted as permeate. The bulk of dissolved ions and particles are rejected, and diverted to drain. STERILIZE: To kill or destroy all microorganisms. SURFACTANT (SURFACE-ACTIVE AGENT): The material in a soap or detergent formulation that promotes the loosening of the soil from surfaces and the suspension of many soils. The actual cleaning agent in soaps and detergents. SUSPENSION: Foreign particles carried in a liquid but not dissolved in it, like rusty iron in water. Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Section Table of Contents GLOSSARY 252 SWELLING: The expansion of certain ion exchange resins when converted into specific ionic states. T TANGENTIAL FLOW: Action whereby the untreated water (feed) flow is directed across the surface of the membrane. This “sweeping” action helps keep material retained by the membrane from settling, and eventually restricting, permeate flow. TEMPERATURE CORRECTION FACTOR: The factor by which the water system productivity (RO or UF) would be reduced (or increased) due to changes in water temperature. Water viscosity changes with changes in temperature, and therefore the rate at which it will pass through a membrane, will change accordingly. As a rule of thumb, the system productivity may be decreased by about 2 percent per °C decrease in temperature. THROUGHPUT: The total volume of fluid processed through the filters before membrane fouling occurs. Throughput is measured in liters of filtrate produced. TOTAL CHLORINE: The total concentration of chlorine in a water sample, including combined and free chlorine. TOTAL DISSOLVED SOLIDS (TDS): The total of all dissolved matter (both organic and inorganic) present in a water sample. TOTAL HARDNESS: The sum of all hardness constituents in a water sample, expressed as their equivalent concentration of calcium carbonate. Hardness is caused primarily by calcium and magnesium, but may also include small amounts of metals such as iron which act like calcium and magnesium in certain reactions. TOTAL ORGANIC CARBON (TOC): One method for determining the organic content of a water sample (from approximately 10 ppb to thousands of ppm). In this method the organic matter is oxidized to carbon dioxide, which is then measured by one of several sensitive electronic detectors. Other methods of determining the organic content in a water sample include Chemical Oxygen Demand (COD), Ultraviolet Spectrophotometr y, Gas Chromatography and Mass Spectrometry. TOTAL SOLIDS: The weight of all solids, dissolved and suspended, organic and inorganic, per unit of water. TRANSMEMBRANE PRESSURE: Short for transmembrane differential pressure. The difference between the feed pressure applied to the upstream as compared to that of the feed pressure on the downstream (permeate) side of the membrane. Transmembrane pressure is essentially the “net driving force” that determines “flux”. Transmembrane pressure is calculated as follows: Feed Pressure = 250 psi = 50 psi –Permeate Pressure Transmembrane Pressure= 200 psi TURBIDITY: A term used to define the physical appearance or cloudiness of water. Expressed in NTUs, turbidity is determined by how much undissolved material, such as clay, silt or sand is present in water. TWO PASS: Refers to a two-pass RO system in which a portion of the feed water to the system will pass through two RO membranes to be purified. U ULTRAFILTRATION: A filtration process using membrane filter material to retain undissolved and dissolved contaminants that are larger than the nominal molecular weight cutoff rating of the membrane (typically 5,000-500,000 daltons). Essentially a molecular sieve. Ultrafiltration systems use this process to dramatically reduce contaminants not removed by microporous filtration, such as large molecular weight organics, colloids, bacteria, and particles smaller than the absolute ratings of “microporous” or “absolute” filters. Ultrafiltration differs from reverse osmosis as a process in that it typically will not remove dissolved salts. ULTRAVIOLET STERILIZATION: Using ultraviolet (UV) radiation to kill or inhibit bacteria and viruses. UPFLOW: The operation of an ion exchange unit in which solutions are passed in at the bottom and out at the top of the vessel. USP: United States Pharmacopoeia. Publishes standards for water for injection (pharmaceutical) and purified water. V VIRUS: An infective agent smaller than a common bacterium. Requires living cells for multiplication. VISCOSITY: The resistance of fluids to flow, due to internal forces and friction between molecules. W WFI: Abbreviation for “water for injection”. Used in preparing injectable pharmaceuticals, WFI must be pyrogen-free. Z ZEOLITE: A group of natural or synthetic hydrated aluminum silicates with ion exchange properties. Siemens Water Technologies 24-hr Customer Service: 800.466.7873 BACK Section Table of Contents TRADEMARK STATEMENT 253 APEX. AquaCarb, Arrowhead, AVGF, BevMAX, CDI, CDI-LX, CHEM-AD, Chemtube, Continental, Depolox, DI Gard, DI-SDI Alert, EPV, FlexTrex, FlexRO, High Resolution Redox, Ionpure, IWT, KISCO, LiquiPure, MED-RO, MEDICA, Membrane Care, Midas, MODULAB, Penfield, Permutit, PreFlex, Prepure DP, PreVUE, PolyBlend, Postpure PP, PureFit, ROGARD, Stranco, Strantrol, TotalCheck, Vantage, VoCarb, Wallace & Tiernan, USF, Westates and WinCPD are trademarks of Siemens, its subsidiaries or affiliates. Santoprene is a trademark of Advanced Elastomer Systems, LP ANSI is a trademark of the American National Standards Institute ASME is a trademark of the American Society of Mechanical Engineers ASTM is a trademark of the American Society for Testing and Materials ATCC is a trademark of the American Type Culture Collection AWWA is a trademark of the American Water Works Association Aquafine and Aqualogic 2000 are trademarks of Aquafine Corporation Barnstead, B-pure, E-pure, G-pure, Diamond, EASYpure NANOpure, NANOpure Infinity, ORGANICfree, ROpure and ULTROpure are trademarks of Barnstead/Thermolyne Corporation CLSI is a trademark of the Clinical Laboratory and Standard Institute Dow, Dowex, Dowex Marathon and Monosphere are trademarks of Dow Chemical Company Viton is a trademark of DuPont Performance Elastomers LLC Teflon is a trademark of E.I. du Pont de Nemours & Company CENTRA, MEDICA and PURELAB are trademarks of ELGA LabWater FILMTEC is a trademark of FilmTec Corporation CoLD and Nexis are trademarks of Filterite Corporation E-Cell is a trademark of GE Water Technologies, Inc. Grundfos is a trademark of Grundfoss Bjerringbro Pumpefabrik A/S Corporation Anatel and Hach are trademarks of Hach Company Hydranautics is a trademark of Hydranautics Corporation Actiflo is a trademark of Kruger, Inc. Lewatit and MonoPlus are trademarks of Lanxess Deutschland GmbH LMI is a trademark of Liquid Metronics Incorporated AFS, Alpha-Q, AFS, Milli-Q, Milli-RO, Millipore and Super-Q are trademarks of Millipore Corporation Diaion is a trademark of Mitsubishi Chemical Corporation Ultrameter is a trademark of Myron L. Company Thio-Bag and Whirl-Pak are trademarks of NASCO NEMA is a trademark of the National Electrical Manufacturers Association Propor is a trademark of Parker Domnick Hunter Clerify is a trademark of Pentair Filtration, Inc. Chem-Tech, Chem-Tech Prime Performance, IntelliScan, IntelliSense, MICROtrac, PULSAtrol and PULSAtron are trademarks of Pulsafeeder Inc., a unit of IDEX Corporation Purolite is a trademark of The Purolite Company Allen-Bradley is a trademark of Rockwell Automation, Inc. Amberjet and Amberlite are trademarks of Rohm & Haas Fluran is a trademark of Saint-Gobain Performance Plastics Ionac is a trademark of Sybron Chemicals, Inc. Terrapure is a trademark of Terracon Corporation Trisep is a trademark of TriSep Corporation cUL and UL are trademarks of Underwriters Laboratories, Inc. USP is a trademark of The United States Pharmacopeial Convention Victaulic is a trademark of Victaulic Company Siemens Water Technologies Technical Support 800.875.7873 ext. 5000 BACK Main Table of Contents For more information contact: Siemens Water Technologies 10 Technology Drive Lowell, MA 01851 North America and Canada 800.875.7873 ext. 5000 Technical Support 800.466.7873 Customer Service tech.support.water@siemens.com Information Desk 800.525.0658 Toll Free +724.772.1402 International information.water@siemens.com www.siemens.com/water The information provided in this catalog contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of the contract. ©2007 Siemens Water Technologies Corp. All Rights Reserved CO-BLUE-CAT-0307 Subject to change without prior notice. Main Table of Contents