[ AIR-INSULATED SWITCHGEAR ] 1 PIX DC Direct Current Switchgear for Traction Substations Rail transportation systems are under increasing pressures due to rising traffic volumes and a heightened demand for improved reliability and safety. We keep you connected With hundreds of thousands of MV cubicles ensuring services worldwide in all possible environmental and weather conditions - to the utmost satisfaction of our customers - our switchgear is certainly amongst the most reliable and safe on the market. As a core product of the Schneider Electric medium voltage offer, our PIX Medium Voltage switchgear for primary distribution applications ranges from 7.2 kV to 40.5 kV. This switchgear is metal-clad and internal arc tested. In parallel, Schneider Electric has gained field-proven experience in the railway segment, delivering solutions to customers ranging from distribution switchgear, rectifier transformers - up to a complete substation on request. Today, combining experience with expertise, we have enhanced our offer with our direct current switchgear, PIX DC. Customer Benefits > Robust construction based on Medium > Voltage metal clad design > Withdrawable circuit breaker > Easy access to all components > All operations are possible from the front Major rail references From the AC network to your DC outgoing power, you will benefit from PIX's field-proven robustness, providing efficient and reliable power for your vehicles. Designed for light rail transit, trolley bus and metro PIX DC, equipped with a High Speed Circuit Breaker (HSCB), is dedicated to direct current applications up to 1,500 V and 6,000 A such as light rail systems or tramways and metros. Aligned with the 650 mm standard circuit breaker cubicle is a disconnector unit of the same width, as well as a rectifier cubicle of 1000 mm. To allow you to design your substation with enhanced flexibility, the cubicles can be arranged in various combinations. [ AIR-INSULATED SWITCHGEAR ] Direct Current Switchgear 2 Description Busbar compartment PIX DC metal clad switchgear (indoor type) has four separate compartments: • High Speed Circuit Breaker compartment • Busbar compartment • Cable compartment • Low voltage compartment (protection and • control) The busbar is made of copper with the following density recommended by EN standards: 1.3 A / mm² from 3,000 A to 6,500 A. Resistance for line test can also be installed in this compartment based on the application or customer request. Cable compartment All the main components are easily accessible from the front and the panels are suitable for a back to wall installation. All operations can be possible from the front panel. Access to the cable compartment is possible from rear and front ( with the CB extracted). The measuring shunt is inserted in the cable compartment. High speed circuit breaker compartment The single pole 750 or 1,500 V High Speed Circuit breaker is mounted in a removable trolley which can be easily drawn in or out of the cubicle. Door opening at a minimum of 120° facilitates the manipulation of the HSCB. The inspection window in the front door allows the operator to monitor the circuit breaker (counter, open/close position, rack-in device position) All operations are performed from the front with the doors closed. Resistance for line test is included in this compartment. PIX DC Switchgear HSCB Circuit Breaker [ AIR-INSULATED SWITCHGEAR ] Direct Current Switchgear Low voltage compartment PIX DC rectifier panel The standard low voltage cabinet is available in three heights, as in our PIX range: 530 / 630 / 730 mm. Other dimensions are available on request. The rectifier function is usually ensured by 2 rectifiers (phase difference 30°, performed by secondary of transformer), which can fit in our PIX DC 1000 mm width cubicles. This low voltage cabinet is spacious and all relay, instrument and control devices are mounted not higher than 2 m. This cubicle can be aligned directly with the disconnector or HSCB panel. PIX DC disconnector cubicle Full integration... Aligned with our CB cubicle, the disconnector switchgear can be proposed. One or two disconnectors can be fitted in the cubicle: manual and motorized versions are available. With PIX DC switchgear, Schneider Electric can equip your entire substation with the electrical equipment you need: including AC Medium Voltage switchgear (Air-or Gas-insulated Switchgear), the transformer, rectifiers, and of course protection and control systems. These cubicles are used for negative return and/or positive busbar supply. On request, we can provide you with a global power management solution. ...and full services From substation design to erection, commissioning, maintenance and repair - our experts are there for you all the way. You need efficiency and reliability. We keep you on track! 3 [ AIR-INSULATED SWITCHGEAR ] Direct Current Switchgear 4 Technical characteristics Schneider Electric SA 35 rue Joseph Monier 92500 Rueil Malmaison France Phone: +33 (0) 1 41 29 70 00 Fax: +33 (0) 1 41 29 71 00 www.schneider-electric.com 08/2010