SpectrAlert More Choices More Features More Flexibility Less Power wall Wall-mount SpectrAlert ™ Product installation is An innovative and ef fi- simple because the cient circuit design back box is left open allowed System Sensor for wiring. A universal to revolutionize notifi- mounting plate comes cation devices with its line of SpectrAler t with each unit and ™ offers one-screw mount- wall-mount strobes, ing, fur ther reducing horn/strobes, and install time. horns. This new design results in dramatically reduced current draw and a lower overall installed cost. ceiling Ceiling-mount SpectrAlert™ series draw up to 40% SpectrAler t’s newest less current than compet- strobes, horn/strobes, itive designs. and speaker/strobes are designed specifically for A unique, circular design the ceiling. Based on the blends with other ceiling- same principles as the mount devices such popular wall-mount mod- as smoke detectors, for els, the ceiling-mount an unobtrusive installation. And this aesthetic is common throughout the ceiling product line, for a consistent appearance. Installer-friendly features such as captured mounting screws and dip switch horn tone selections simplify installation. SpectrAlert™ Speakers To reduce installation SpectrAler t™ speakers costs, they can be and speaker/strobes mounted to a 4 in. x give you the fidelity 4 in. x 2-1/8 in. back sound quality essential box, without an exten- to voice evacuation. sion ring. These products provide a broad frequency range and low harmonic distor tion for cr ystal clear sound per formance, making them ideal for hotel, hospital, and voice commercial applications. sync Synchronization is Easy may be interconnected The SpectrAler t with other Sync •Circuit ™ Sync•Circuit ™ Module modules for multi-zone is designed to make synchronization. It is installations that compatible with wall require signal synchro- or ceiling-mount strobes, nization easy. This horn/strobes, speaker/ patented product syn- strobes, and wall- chronizes SpectrAler t™ mount horns. strobes to flash at 1Hz and SpectrAler t™ horns to sound at temporal 3 over one pair of wires. This technology can also silence horns, and SpectrAlert Specifications ULC Canadian Models are available. SpectrAlert Wall Mount Horn/Strobes Red Model White Model Voltage Candela Avg. mA* @Nom. VDC P1215 P1215W 12 15 124 Avg. mA* @Nom.FWR** 167 P121575 P121575W 12 15/75 152 181 P2415 P2415W 24 15 68 78 P241575 P241575W 24 15/75 74 82 P2430 P2430W 24 30 92 100 P2475 P2475W 24 75 148 167 P24110 P24110W 24 110 165 209 Avg. mA @Nom.FWR** SpectrAlert Wall Mount Strobes Red Model White Model Voltage Candela Avg. mA @Nom. VDC S1215 S1215W 12 15 114 157 S121575 S121575W 12 15/75 142 171 S2415 S2415W 24 15 43 60 S241575 S241575W 24 15/75 49 64 S2430 S2430W 24 30 67 82 S2475 S2475W 24 75 123 159 S24110 S24110W 24 110 140 191 SpectrAlert Wall Mount Horns Red Model White Model Voltage Candela Avg. mA* @Nom. VDC Avg. mA* @Nom.FWR** H12/24 H12/24W 12/24 NA 10/25 10/18 SpectrAlert Wall Mount Weatherproof Red Model Description Voltage Candela Avg. mA* @Nom. VDC Avg. mA* @Nom.FWR** P121575K Horn/Strobe 12 15/75 124 167 P241575K Horn/Strobe 24 15/75 74 82 P2475K Horn/Strobe 24 75 148 167 P24110K Horn/Strobe 24 110 165 209 S121575K Strobe 12 15/75 142 171 S241575K Strobe 24 15/75 49 64 S2475K Strobe 24 75 123 159 S24110K Strobe 24 110 140 191 H12/24K Horn 12/24 NA 10/25 10/18 SpectrAlert Wall Mount AGENT, EVAC, FUEGO Models Red Model Description Voltage Candela Avg. mA* @Nom. VDC Avg. mA* @Nom.FWR** P241575AG AGENT Horn/Strobe 24 15/75 74 82 P241575EV EVAC Horn/Strobe 24 15/75 74 82 P241575F FUEGO Horn/Strobe 24 15/75 74 82 S241575AG AGENT Strobe 24 15/75 49 64 S241575EV EVAC Strobe 24 15/75 49 64 S241575F FUEGO Strobe 24 15/75 49 64 *Horn and Horn/strobe current draws assume horn is set at temporal 3, electromechanical tone, and high audibility. ** FWR = Full Wave Rectified SpectrAlert Ceiling Mount Horns/Strobes Red Model White Model Voltage Candela Avg. mA* @Nom. VDC PC2415 PC2415W 24 15 71 Avg. mA* @Nom.FWR** 89 PC241575 PC241575W 24 15/75 79 96 PC2430 PC2430W 24 30 91 113 PC2475 PC2475W 24 75 150 174 PC2495 PC2495W 24 95 176 207 PC24115 PC24115W 24 115 214 264 PC24177 PC24177W 24 177 314 334 Avg. mA @Nom.FWR** SpectrAlert Ceiling Mount Strobes Red Model White Model Voltage Candela Avg. mA @Nom. VDC SC2415 SC2415W 24 15 48 55 SC241575 SC241575W 24 15/75 56 62 SC2430 SC2430W 24 30 68 79 SC2475 SC2475W 24 75 127 140 SC2495 SC2495W 24 95 153 173 SC24115 SC24115W 24 115 191 230 SC24177 SC24177W 24 177 291 300 Avg. mA @Nom.FWR** SpectrAlert Ceiling Mount Speaker/Strobes White Model Voltage Candela Avg. mA @Nom. VDC SP2C2415 24 15 48 55 SP2C241575 24 15/75 56 62 SP2C2430 24 30 68 79 SP2C2475 24 75 127 140 SP2C2495 24 95 153 173 SP2C24115 24 115 191 230 SP2C24177 24 177 291 300 SpectrAlert Dual Voltage Evacuation Speakers Red Model White Model Description Speaker Voltage – SP200W Round 73⁄8” grille, 1⁄4 -2 watt power tap 25.0/70.7 Vrms SP201R SP201W Square, 5” grille, 1⁄4 -2 watt power tap 25.0/70.7 Vrms SpectrAlert Wall Mount Speaker/Strobes Red Model White Model Voltage Candela Avg. mA @Nom. VDC SP2R2415 SP2W2415 24 15 43 Avg. mA @Nom.FWR** 60 SP2R241575 SP2W241575 24 15/75 49 64 SP2R2430 SP2W2430 24 30 67 82 SP2R2475 SP2W2475 24 75 123 159 SP2R24110 SP2W24110 24 110 140 191 SpectrAlert Sync•Circuit Module Red Model White Model Voltage Candela Avg. mA* @Nom. VDC Avg. mA* @Nom.FWR** MDL MDLW 12/24 NA 16 24 SpectrAlert Accessory Mounting Plates Red Model White Model Description S-MP S-MPW Small footprint mounting plate for single gang only BBS BBSW Sur face-mount back box skir t D-MP D-MPW Universal mounting plate (replacement) WBB — Weatherproof back box BBSC BBSCW Sur face-mount back box skir t for ceiling mount products BBS-SP2R BBS-SP2W Sur face-mount back box skir t for wall mount speaker/strobe *Horn and Horn/strobe current draws assume horn is set at temporal 3, electromechanical tone, and high audibility. ** FWR = Full Wave Rectified SpectrAlert is the full line of notification devices that saves you time and money while giving you flexibility and end-user appeal. The savings you realize are tangible — less power consumption means more devices per circuit and fewer power supplies. Less time to install means more time to focus on other business. ™ System Sensor 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800.SENSOR2 Fx: 630.377.6495 www.SystemSensor.com Fx Documents: 800-736-7672 ext. 3 © 2000 System Sensor The company reser ves the right to change specifications at any time. A05–1026–01