2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0428-6 Name: 5C-428 5C 100: DATE: JAN 19 2006 Time: 5:25:03 PM Operator: GK COLOR: CMYK Dimensions Pg. 430 Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled and are used: ɀ to prevent arcing of enclosed device from causing ignition of a specific hazardous atmosphere or atmospheres external to the enclosure ɀ in industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas, or metal handling or finishing areas where atmosphere may contain hazardous gases and/or dust ɀ in non-hazardous areas where sturdy, durable enclosures are required ɀ in conjunction with magnetic starters or contactors for remote control of motors Manual motor starting switch enclosures are used: ɀ for manual starting of small ac or dc motors ɀ to provide manual starting and stopping and, in the case of units with heaters, motor running protection Features: Factory sealed devices have many distinct advantages: ɀ reduce installation problems ɀ eliminate external seals ɀ lower installation costs ɀ improve safety ɀ are used with general purpose snap and pushbutton type switches ɀ standard neoprene covers for front operated pushbuttons. Prevents accumulation of dirt and entrance of water around operating shafts ɀ mounting lugs and taper tapped hubs with integral bushings ɀ large machine screws for fastening covers to bodies ɀ lockout provisions on front operated push button (marked ‘‘STOP’’ and ‘‘OFF’’) and selector switch covers ɀ lockout hole for padlock having 1⁄4⍯ hasp is provided when used with covers for front lever and side rocker type operation ɀ close tolerances in machining of wide, mating flanges and journalled shafts and bearings for front button operation, produces flametightness of enclosure joints ɀ on enclosures with front lever and side rocker type operating handles, threaded type shafts and bushings are used to ensure flametightness ɀ dead end (EFS or EDS) or through feed (EFSC or EDSC) hubs – 1⁄2⍯ to 1⍯ sizes ɀ Shafts – stainless steel ɀ Shaft bushings – stainless steel ɀ Rocker handle and pushbutton guards – type 6/6 nylon ɀ Sealing enclosures – copper-free aluminum Standard Finishes: Feraloy iron alloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural ɀ Type 6/6 nylon – black ɀ Stainless steel – natural ɀ NEC/CEC: Class I, Division 1 & 2, Groups B*,C,D Class II, Division 1, Groups E,F,G Class II, Division 2, Groups F,G Class III ɀ NEMA/EEMAC: 3,7B*CD,9EFG ɀ UL Standard: 894, 698 ɀ CSA Standard: C22.2 No. 30 Options: The following special options are available from the factory by adding suffix to Cat. No. Suffix to be Added to Cat. # Description Emergency ‘‘Stop’’ button (momentary) – front operated red mushroom button . . . . . . . . . . S111 Lockout provision on front operated pushbutton cover (standard on buttons marked ‘‘OFF’’ and ‘‘STOP’’) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S153 For 24 VDC operation on pilot lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S300 Three-position selector switches with modified operation: Momentary contact clockwise operation, spring return to center, maintained contact counter-clockwise operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S634 Momentary contact counter-clockwise operation, spring return to center, maintained contact clockwise operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S635 Bodies and covers (single and two gang units) – copper-free aluminum. . . . . . . . . . . . . . . . . . . SA Where indicated in the catalog listings, EDS units suitable for Class I, Division 1, Group B usage can be supplied, add suffix - GB, EFS units are suitable for Class I, Division 1, Group B as standard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GB Maintained contact mushroom head with lockout and guard. Maximum one per cover and cannot be used with a pilot light with a transformer or another standard pushbutton.. . S769 EDS bodies and factory sealed cover and device sub-assemblies are available for field assembly (see pages 394 to 396). ɀ Bodies – Feraloy® iron alloy; copper-free aluminum. ɀ Front operated pushbutton and pilot light covers – Feraloy iron alloy ɀ Side operated type pushbutton covers – copper-free aluminum STIBOINFO((CRH:66008com:5C:428)) CH0 0 5 C- 0 Explosionproof Dust-Ignitionproof Raintight Wet Locations Certifications and Compliances: Suffix S769 Standard Materials: 428 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups B*,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,7B*CD,9EFG EFS and EDS Factory Sealed Control Devices and Manual Motor Starting Switches Application: TCP: 15001 US: 1-866-764-5454 * See Options: suffix GB CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0431-6 Name: 5C-431 DATE: JAN 19 2006 Time: 5:25:06 PM Operator: RB TCP: 15001 Cl. I, Div. 1 & 2, Groups B*,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,7B*CD,9EFG EDS Factory Sealed Pushbutton Stations Front Operated, 600VAC Heavy Duty, Dimensions Pg. 430 EDS2184 COLOR: CMYK Typedriver Name: TS name csm no.: 100 Explosionproof Dust-Ignitionproof Raintight Wet Locations 5C EDS2190 Single Gang Normal Pos. 1 Circuit Universal 2 Circuits Universal 2 Circuits** Marking † Specify Specify START-STOP unless otherwise specified ED11 ED12 ED12** Cat. # EDS2190 EDS3190 Cat. # EDS115 EDS215 EDS315 EDSC1190 EDSC2190 EDSC3190 EDSC115 EDSC215 EDSC315 Diagram Replacement Pushbuttons‡ Enclosure with Pushbuttons Hub Size 1⁄2 3⁄4 1 1⁄2 3⁄4 1 Dead End Cat. # EDS1184 EDS2184 EDS3184 Through Feed EDSC1184 EDSC2184 EDSC3184 Normal Pos. 2 Circuits Universal 2 Circuits** Marking † Specify Specify Diagram Replacement Pushbuttons‡ ED12 Enclosure with Pushbuttons Hub Size 1⁄2 3⁄4 1 1⁄2 3⁄4 1 Dead End Cat. # § ED12** Cat. #§ EDS1155 EDS2155 EDS3155 EDS2192 EDS3192 Through Feed EDSC1192 EDSC1155 EDSC2192 EDSC2155 EDSC3192 EDSC3155 * Class I, Group B: Consider using EFS series pushbuttons, see page 433. All enclosures listed above can be modified for Class I, Group B, Div. 1 usage. Add suffix GB to the Cat. No. Seals must be installed within 11⁄2⍯ of each conduit opening in Division 1. These products are suitable for Group B, Div. 2 as listed, without external seals. In Canada, for Group B applications consult factory. ** Two universal contact blocks, must be wired as two circuits, with one normally open and one normally closed. § Single external button operates both inner buttons simultaneously. † Standard markings available are as follows: START OFF RESET LIGHT ON EMERGENCY OPEN DOWN RAISE STOP RUN TRIP HAND FORWARD CLOSE IN LOWER ON JOG TEST AUTOMATIC REVERSE UP OUT ‡ For replacement contact blocks, see page 400. US: 1-866-764-5454 STIBOINFO((CRH:66008com:5C:431)) CH0 0 5 C- 4 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 431 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0432-6 Name: 5C-432 5C 100: DATE: JAN 19 2006 Time: 5:25:07 PM Operator: RB EDS Factory Sealed Pushbutton Stations Front Operated, 600VAC Heavy Duty, Dimensions Pg. 430 COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups B*,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,7B*CD,9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations EDSC225 Two Gang Normal Pos. 1 Circuit Universal 2 Circuits Universal 2 Circuits** Marking † Specify Specify START-STOP unless otherwise specified ED12 ED12** Cat. # EDS2290 EDS3290 Cat. # EDS225 EDS325 EDSC1290 EDSC2290 EDSC3290 EDSC125 EDSC225 EDSC325 Diagram Replacement Pushbuttons ‡ ED11 Enclosure with Pushbuttons Hub Size 3⁄4 1 1⁄2 3⁄4 1 Dead End Cat. # EDS2284 EDS3284 Through Feed EDSC1284 EDSC2284 EDSC3284 * Class I, Group B: Consider using EFS series pushbuttons, see page 433. All enclosures listed above can be modified for Class I, Group B, Div. 1 usage. Add suffix GB to the Cat. No. Seals must be installed within 11⁄2⍯ of each conduit opening in Division 1. These products are suitable for Group B, Div. 2 as listed, without external seals. In Canada, for Group B applications consult factory. * * Two universal contact blocks, must be wired as two circuits, with one normally open and one normally closed. § Single external button operates both inner buttons simultaneously. † Standard markings available are as follows: START OFF RESET LIGHT ON EMERGENCY OPEN DOWN RAISE STOP RUN TRIP HAND FORWARD CLOSE IN LOWER ON JOG TEST AUTOMATIC REVERSE UP OUT ‡ For replacement contact blocks, see page 400. 432 STIBOINFO((CRH:66008com:5C:432)) CH0 0 5 C- 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0433-4 Name: 5C-433 DATE: JAN 19 2006 Time: 5:25:09 PM Operator: RB EFS Factory Sealed Pushbutton Stations Front Operated, 600VAC Heavy Duty, Dimensions Pg. 430 EFS2184 COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups B*,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,7B*CD,9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations EFSC2190 Normal Pos. 1 Circuit Universal 2 Circuits Universal 2 Circuits** Normal Pos. 2 Circuits Universal 2 Circuits** Marking † Specify Specify START-STOP unless otherwise specified Marking† Specify Specify ED12 ED12** Enclosure with Pushbuttons ED11 ED12 ED12** Enclosure with Pushbuttons Hub Size 1⁄2 3⁄4 1 1⁄2 3⁄4 1 Diagram Replacement Pushbuttons‡ Diagram Replacement Pushbuttons‡ 5C Dead End Cat. # EFS1184 EFS2184 EFS3184 Cat. # EFS2190 EFS3190 Through Feed EFSC1184 EFSC1190 EFSC2184 EFSC2190 EFSC3184 EFSC3190 Cat. # EFS115 EFS215 EFS315 Hub Size 1⁄2 3⁄4 1 1⁄2 3⁄4 1 Dead End Cat. # § Cat. #§ EFS1155 EFS2155 EFS3155 EFS2192 EFS3192 Through Feed EFSC1192 EFSC1155 EFSC2192 EFSC2155 EFSC3192 EFSC3155 EFSC115 EFSC215 EFSC315 * Class I, Group B: All enclosures listed above are suitable for Class I, Group B, Div. 1 usage. Seals only have to be installed on 1 inch conduit within 5 ft. in Division 1. ** Two universal contact blocks, must be wired as two circuits, with one normally open and one normally closed. § Single external button operates both inner buttons simultaneously. † Standard markings available are as follows: START OFF RESET LIGHT ON EMERGENCY OPEN DOWN RAISE STOP RUN TRIP HAND FORWARD CLOSE IN LOWER ON JOG TEST AUTOMATIC REVERSE UP OUT ‡ For replacement contact blocks, see page 400. US: 1-866-764-5454 STIBOINFO((CRH:66008com:5C:433)) CH0 5 C- 1 2 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 433 Zoom: 100