Universal Occupancy/Vacancy Sensors

advertisement
PRODUCT SPECIFICATIONS
Universal
Occupancy/Vacancy
Sensors
All models have screw terminals for easy installation and
most do not require a neutral wire for connection. The
devices feature a time delay setting which allows users
the option to delay the lights/motor load from switching
off for 30 seconds, 5 minutes, 15 minutes or 30 minutes.
For example, closet lighting would ideally be set to turn OFF
in 30 seconds while a bathroom fan may be set to turn OFF
15 minutes after the space is vacated.
Featured in the new line is the IPVD6/IPSD6, a dimming sensor
providing users the ability to easily adjust lighting levels of
compatible dimmable LED, dimmable CFL and Incandescent
lamps for energy-efficiency and ambiance. A built-in
advanced starting technology ensures instant start-up
for hard to start CFLs.
In addition to the Dimming Sensor, the new line offers
a selection of occupancy and vacancy sensors with
specifications to meet any requirement. The single pole
IPV05/IPS05 and single pole or 3-way IPS15/IPV15 models are
ideal for controlling motor loads such as exhaust fans as well
as higher wattage lighting loads. They are relay-based, easily
replace a standard switch and are discrete in appearance.
Applications
Leviton’s Occupancy and Vacancy Sensors can
be used in a variety of residential settings including:
Bathrooms
Garages
Hallways
Basements
Utility/Laundry Rooms
Living/Family Rooms
Bedrooms
Dining Rooms
Kitchens
For use with LED, CFL and Incandescent lamps
GENERAL OPERATION
Leviton’s sensors use passive infrared (PIR) detection
technology to monitor a room for occupancy through a
segmented lens. This specialized lens divides the field of
view into sensor zones. The sensors are available
as Automatic-ON (occupancy) or Manual-ON (vacancy)
detectors.
MANUAL-ON OPERATION (Vacancy Sensors)
Vacancy sensors require the user to manually press the
push-button to turn loads ON. The loads will remain ON
as long as the device detects activity in the sensor zone.
The device will not turn loads ON automatically when
motion is detected. Loads may be manually turned OFF
at any time by pressing the push-button. Leviton vacancy
sensors are CA Title 24 compliant.
AUTOMATIC–ON OPERATION (Occupancy Sensors)
Occupancy sensors switch lights ON automatically when
motion is detected. The lights will remain ON as long as
the device detects activity in the sensor zone. Lights may
also be switched OFF at any time by manually pressing
the push-button.
All Leviton occupancy sensors feature an override
function which, when activated, allows the device to
operate as a vacancy sensor.
Universal Occupancy/Vacancy Sensors
Leviton’s new line of Occupancy and Vacancy Sensors
combine state-of-the-art technology with new aesthetics to
provide optimal management of lighting and motor loads and
a choice of either Manual-ON (Vacancy Sensor) or AutomaticON (Occupancy Sensor) switching. These energy-saving
sensors are engineered to ensure that lights/motors will turn
ON manually or automatically and turn OFF automatically
when motion is no longer detected within the covered range.
Designed to fit in a standard wallbox, these devices offer 180°
Field of View and 900 sq. ft. of coverage.
PRODUCT SPECIFICATIONS
Features and Benefits
-A
ll models available in Manual-ON or Automatic-ON
providing users the option to choose the functionality
that best suits their needs
-S
crew terminals for easier installation
-V
ariety of models for control of LED, CFL, Incandescent,
Halogen or Motor loads
-P
rovides 180° Field of View, 900 sq. ft. coverage making
these devices suitable for use in large areas such as
basements, garages and living rooms
- L ow profile design blends in with walls for a discreet
appearance
-A
mbient light override prevents occupancy sensors
from switching the lights ON when there is ample
natural sunlight
-A
djustable delayed OFF time which can be set for 30
seconds, 5 minutes, 15 minutes or 30 minutes for
effective energy management
-N
eutral not required in most models for ease of
installation in remodel or new construction
-C
A Title 2o Compliant*
- IPV05, IPVD6 and IPV15 are CA Title 24 Compliant
-C
ontemporary styling in line with Leviton’s Decora®
line of wiring devices
-C
ompatible with Decora screwless wallplates
-C
olor change kits are available providing easy coordination with other room elements and the ability to update
the look of the device with changes in décor
30ft
Universal Occupancy/Vacancy Sensors
SENSING AREA COVERAGE
9.1m
6ft
5ft Field-of-View
1.8m
1.5m
(Horizontal)
30ft
9.1m
5ft
1.5m
6ft
1.7m
6ft
1.8m
Relay Sensor – IPS05 / IPV05
-S
ingle pole only
-C
ompatible with LED, CFL, Incandescent, and Fluorescent loads
- Ideal for lighting loads, bath fans and other Motor controls
throughout the home
-R
elay-based sensor for reliable switching of desired load
-N
o neutral required for ease of installation in homes where
neutral is not available
Relay Sensor – IPS15 / IPV15
-S
ingle pole or 3-way when used with IPV0R sensor remote
or with VP0SR Vizia + switch remote
- F or use with LED, CFL, Incandescent, Fluorescent Ballast
or Motor loads
- Ideal for higher power lighting and motor loads
-N
eutral required for installations in new construction or where
the neutral wire is accessible
-R
elay-based sensor provides reliable switching of
desired load
- IPV0R sensor remote
• Manual ON occupancy sensor remote
• 180°, 900 sq. ft. coverage
5ft
1.5m
5ft
1.5m
6ft
1.7m
Dimming Sensor - IPSD6 / IPVD6
-O
ffers maximum energy savings by combining the functionality of a sensor with the versatility and ambiance control
of a dimmer
-S
ingle pole or 3-way when used with a 3-way switch
-C
ompatible with dimmable LED, dimmable CFL and
Incandescent loads
- Ideal for adjusting lighting loads to create ambiance or
to provide appropriate task lighting
Warranty Information
Five-year limited warranty
30ft
9.1m
Dimensional Drawings
30ft
9.1m
1.75
(44.5)
4.13
(104.8)
3.81
(96.8)
1.22
(30.9)
3.28
(83.3)
27ft
8.4m
8ft
Field-of-View
(Side, Vertical)
2.6m
6ft
8ft
1.7m
2.6m
4ft
1.2m
4ft
1.2m
27ft
8.4m
7ft
2.1m
6ft
1.7m
5ft
1.5m
5ft
1.5m
30ft
9.1m
30ft
9.1m
4ft
1.4m
7ft
2.1m
0.37
(9.3)
4ft
1.4m
*Items meet California code of regulation Title 20, required Feb. 1. 2013
2.72
(69)
PRODUCT SPECIFICATIONS
Specifications At-A-Glance
IPS05
IPV05
IPSD6
IPVD6
IPS15
IPV15
•
•
•
•
•
•
LED
150W
150W
150W
150W
600W
600W
CFL
150W
150W
150W
150W
600W
600W
Incandescent/Halogen
600W
600W
600W
600W
1800W
1800W
Motor
1/6 hp
1/6 hp
-
-
1/2 hp
1/2 hp
Fluorescent Ballast
600W
600W
-
-
1800VA
1800VA
5 amps
5 amps
-
-
-
-
Neutral Required
for Operation
No
No
No
No
Yes
Yes
Ground Required
for Operation
Yes
Yes
≈ No
No
No
No
Voltage, frequency
120VAC, 60 Hz
Load Rating
Resistive
Mechanical
Switching Technology
Relay
Relay
Triac
Triac
Relay
Relay
Single Pole/3-Way
or Single Pole
Single
Pole
Single
Pole
Single
Pole/3-Way
Single
Pole/3-Way
Single
Pole/3-Way
Single
Pole/3-Way
180°, 900 Sq. Ft.
Coverage
•
•
•
•
•
•
Passive Infrared
Sensing Technology
•
•
•
•
•
•
30s, 5m, 15m, 30m
Time Delay
•
•
•
•
•
•
Ambient Light Override
•
Auto/Manual ON
•
•
Auto ON
Manual ON
Auto ON
Manual ON
Auto ON
Manual ON
•
•
•
•
•
•
Certifications
UL
CA Title 24
Code Compliance
CA Title 20
Code Compliance*
•
•
•
•
•
•
•
•
•
Operating Temperature
0°C to 40°C
•
•
•
•
•
•
Relative Humidity
20% to 90% noncondensing
•
•
•
•
•
•
Storage Temperature
-10°C to 85°C
•
•
•
•
•
•
Environmental
*Items meet California Code of Regulation Title 20, required Feb. 1, 2013
Universal Occupancy/Vacancy Sensors
Features
PRODUCT SPECIFICATIONS
Wiring Diagrams
IPS05/IPV05
IPVD6/IPSD6
Hot (Black)
Black
Sensor
Sensor
Hot (Black)
Sensor
3-Way
Switch
Sensor
Sensor
Hot (Black)
Pigtail
Pigtail
LINE/Black
Use Terminal for 3-Way
Applications Only.
For Single Pole Applications,
Do Not Remove This Label.
Green
Ground
Line
120VAC, 60 Hz
Red
Green
Ground
Pigtail
Line
120VAC
60 Hz
LOAD
Sensor
Hot (Black)
Pigtail
Line
120VAC
60 Hz
3-Way/
Brass
LOAD
Common Terminal
(Black Screw)
Green
Ground
Line
120VAC
60 Hz
LOAD/Red
LO AD
Black
Sensor
First Traveler
Hot (Black)
BK
Pigtail
3-Way
YL/R
LOAD
Common Terminal
(Black Screw)
G
G
LOAD
Use Terminal for 3-Way Applications Only.
For Single Pole Applications,
Do Not Remove This Label.
White
Neutral (White)
Pigtail
Green
Ground
White
RD
(unused)
Black
Line
120 VAC, 60Hz
Sensor
LINE/Black
LOAD
BK
(unu
3-Way Switch
Sensor
LOAD/Red
Black
WH
Green Ground
3-Way/
Brass
RD
Second Traveler
White
WH
Universal Occupancy/Vacancy Sensors
Pigtail
Neutral (White)
Line
120VAC
60 Hz
Common Terminal
(Black Screw)
Switch Remo
WH
Green
Ground
LOAD
First Traveler
Neutral (White)
LINE/Black
First Traveler
3-Way Switch
Sensor
IPS15/IPV15
White
LO AD
White
Neutral (White)
Second Traveler
LOAD
3-Way/
Brass
Second Traveler
LINE/Black
Green
Ground
LOAD/
Red
Black
3-Way/
Brass
Black
LOAD/Red
LO AD
Pigtail
Green
Ground
Neutral (White)
LINE/Black
Green
Ground
Red
First Traveler
Pigtail
Green
Ground
Green
Ground
Line
120VAC
60 Hz
Neutral (White)
3-Way
Switch
Sensor
Hot (Black)
3-Way/
Brass
LOAD/
Red
Common Terminal
(Black Screw)
Neutral (White)
erminal for 3-Way
cations Only.
ngle Pole Applications,
t Remove This Label.
Green Ground
Second Traveler
White
Hot (Black)
LINE/Black
Green
Ground
Line
120VAC, 60 Hz
Black
3-Way
(Brass
Screw)
3-Way Switch
Sensor
Hot (Black)
(Black)
Green
Ground
Switch Remote
Sensor
Hot (Black)
BK
WH
Pigtail
Green Ground
3-Way/
RD
3-Way
Brass
Second Traveler
LOAD
LOAD
WH
Green
Ground
Black
Line
120 VAC, 60Hz
Common
TerminalApplications Only.
Use Terminal
for 3-Way
(Black Screw)
For Single Pole Applications,
First Traveler
Do Not Remove This Label.
Neutral (White)
BK
(unused)
RD
(unused)
YL/RD
BK
Hot (Black)
Green
Ground
RD
3-Way
Line
120 VAC, 60Hz
White
Neutral (White)
Neutral (White)
Ordering Information:
Description
Rating (120VAC)
Cat. No.
Color
Relay Vacancy Sensor, single pole,
180° Field of View, 900 sq. ft. coverage
600W Incand/FL Ballast
150W LED/CFL, 1/6 HP Motor
IPV05
Z
Relay Occupancy Sensor, single pole,
180° Field of View, 900 sq. ft. coverage
600W Incand/FL Ballast
150W LED/CFL, 1/6 HP Motor
IPS05
Z
Dimming Vacancy Sensor, single pole or 3-Way,
180° Field of View, 900 sq. ft. coverage
600W Incand
150W LED/CFL
IPVD6
Z
Dimming Occupancy Sensor, single pole or 3-Way,
180° Field of View, 900 sq. ft. coverage
600W Incand
150W LED/CFL
IPSD6
Z
Relay Vacancy Sensor, single pole or 3-Way, 180°
Field of View, 900 sq. ft. coverage, neutral required
1800W Incand, 600W LED/CFL,
1800VA Magnetic Ballast, 1/2 HP
IPV15
Z
Relay Occupancy Sensor, single pole or 3-Way, 180°
Field of View, 900 sq. ft. coverage, neutral required
1800W Incand, 600W LED/CFL,
1800VA Magnetic Ballast, 1/2 HP
IPS15
Z
For use with IPS15 or IPV15 Sensor
IPV0R
Z
Sensor Remote, 120VAC, Manual-ON, Auto-OFF
Z - Comes packaged with three colors: White, Ivory and Light Almond.
Leviton Manufacturing Co., Inc.
201 North Service Road, Melville, NY 11747-3138
Telephone: 1-800-323-8920 FAX: 1-800-832-9538
Tech Line (8:30AM-7:00PM E.T. Monday-Friday): 1-800-824-3005
Visit our Website at: www.leviton.com/sensors
© 2012 Leviton Manufacturing Co., Inc. All rights reserved.
G-8761/G12-dp
Download