PRODUCT SPECIFICATIONS Universal Occupancy/Vacancy Sensors All models have screw terminals for easy installation and most do not require a neutral wire for connection. The devices feature a time delay setting which allows users the option to delay the lights/motor load from switching off for 30 seconds, 5 minutes, 15 minutes or 30 minutes. For example, closet lighting would ideally be set to turn OFF in 30 seconds while a bathroom fan may be set to turn OFF 15 minutes after the space is vacated. Featured in the new line is the IPVD6/IPSD6, a dimming sensor providing users the ability to easily adjust lighting levels of compatible dimmable LED, dimmable CFL and Incandescent lamps for energy-efficiency and ambiance. A built-in advanced starting technology ensures instant start-up for hard to start CFLs. In addition to the Dimming Sensor, the new line offers a selection of occupancy and vacancy sensors with specifications to meet any requirement. The single pole IPV05/IPS05 and single pole or 3-way IPS15/IPV15 models are ideal for controlling motor loads such as exhaust fans as well as higher wattage lighting loads. They are relay-based, easily replace a standard switch and are discrete in appearance. Applications Leviton’s Occupancy and Vacancy Sensors can be used in a variety of residential settings including: Bathrooms Garages Hallways Basements Utility/Laundry Rooms Living/Family Rooms Bedrooms Dining Rooms Kitchens For use with LED, CFL and Incandescent lamps GENERAL OPERATION Leviton’s sensors use passive infrared (PIR) detection technology to monitor a room for occupancy through a segmented lens. This specialized lens divides the field of view into sensor zones. The sensors are available as Automatic-ON (occupancy) or Manual-ON (vacancy) detectors. MANUAL-ON OPERATION (Vacancy Sensors) Vacancy sensors require the user to manually press the push-button to turn loads ON. The loads will remain ON as long as the device detects activity in the sensor zone. The device will not turn loads ON automatically when motion is detected. Loads may be manually turned OFF at any time by pressing the push-button. Leviton vacancy sensors are CA Title 24 compliant. AUTOMATIC–ON OPERATION (Occupancy Sensors) Occupancy sensors switch lights ON automatically when motion is detected. The lights will remain ON as long as the device detects activity in the sensor zone. Lights may also be switched OFF at any time by manually pressing the push-button. All Leviton occupancy sensors feature an override function which, when activated, allows the device to operate as a vacancy sensor. Universal Occupancy/Vacancy Sensors Leviton’s new line of Occupancy and Vacancy Sensors combine state-of-the-art technology with new aesthetics to provide optimal management of lighting and motor loads and a choice of either Manual-ON (Vacancy Sensor) or AutomaticON (Occupancy Sensor) switching. These energy-saving sensors are engineered to ensure that lights/motors will turn ON manually or automatically and turn OFF automatically when motion is no longer detected within the covered range. Designed to fit in a standard wallbox, these devices offer 180° Field of View and 900 sq. ft. of coverage. PRODUCT SPECIFICATIONS Features and Benefits -A ll models available in Manual-ON or Automatic-ON providing users the option to choose the functionality that best suits their needs -S crew terminals for easier installation -V ariety of models for control of LED, CFL, Incandescent, Halogen or Motor loads -P rovides 180° Field of View, 900 sq. ft. coverage making these devices suitable for use in large areas such as basements, garages and living rooms - L ow profile design blends in with walls for a discreet appearance -A mbient light override prevents occupancy sensors from switching the lights ON when there is ample natural sunlight -A djustable delayed OFF time which can be set for 30 seconds, 5 minutes, 15 minutes or 30 minutes for effective energy management -N eutral not required in most models for ease of installation in remodel or new construction -C A Title 2o Compliant* - IPV05, IPVD6 and IPV15 are CA Title 24 Compliant -C ontemporary styling in line with Leviton’s Decora® line of wiring devices -C ompatible with Decora screwless wallplates -C olor change kits are available providing easy coordination with other room elements and the ability to update the look of the device with changes in décor 30ft Universal Occupancy/Vacancy Sensors SENSING AREA COVERAGE 9.1m 6ft 5ft Field-of-View 1.8m 1.5m (Horizontal) 30ft 9.1m 5ft 1.5m 6ft 1.7m 6ft 1.8m Relay Sensor – IPS05 / IPV05 -S ingle pole only -C ompatible with LED, CFL, Incandescent, and Fluorescent loads - Ideal for lighting loads, bath fans and other Motor controls throughout the home -R elay-based sensor for reliable switching of desired load -N o neutral required for ease of installation in homes where neutral is not available Relay Sensor – IPS15 / IPV15 -S ingle pole or 3-way when used with IPV0R sensor remote or with VP0SR Vizia + switch remote - F or use with LED, CFL, Incandescent, Fluorescent Ballast or Motor loads - Ideal for higher power lighting and motor loads -N eutral required for installations in new construction or where the neutral wire is accessible -R elay-based sensor provides reliable switching of desired load - IPV0R sensor remote • Manual ON occupancy sensor remote • 180°, 900 sq. ft. coverage 5ft 1.5m 5ft 1.5m 6ft 1.7m Dimming Sensor - IPSD6 / IPVD6 -O ffers maximum energy savings by combining the functionality of a sensor with the versatility and ambiance control of a dimmer -S ingle pole or 3-way when used with a 3-way switch -C ompatible with dimmable LED, dimmable CFL and Incandescent loads - Ideal for adjusting lighting loads to create ambiance or to provide appropriate task lighting Warranty Information Five-year limited warranty 30ft 9.1m Dimensional Drawings 30ft 9.1m 1.75 (44.5) 4.13 (104.8) 3.81 (96.8) 1.22 (30.9) 3.28 (83.3) 27ft 8.4m 8ft Field-of-View (Side, Vertical) 2.6m 6ft 8ft 1.7m 2.6m 4ft 1.2m 4ft 1.2m 27ft 8.4m 7ft 2.1m 6ft 1.7m 5ft 1.5m 5ft 1.5m 30ft 9.1m 30ft 9.1m 4ft 1.4m 7ft 2.1m 0.37 (9.3) 4ft 1.4m *Items meet California code of regulation Title 20, required Feb. 1. 2013 2.72 (69) PRODUCT SPECIFICATIONS Specifications At-A-Glance IPS05 IPV05 IPSD6 IPVD6 IPS15 IPV15 • • • • • • LED 150W 150W 150W 150W 600W 600W CFL 150W 150W 150W 150W 600W 600W Incandescent/Halogen 600W 600W 600W 600W 1800W 1800W Motor 1/6 hp 1/6 hp - - 1/2 hp 1/2 hp Fluorescent Ballast 600W 600W - - 1800VA 1800VA 5 amps 5 amps - - - - Neutral Required for Operation No No No No Yes Yes Ground Required for Operation Yes Yes ≈ No No No No Voltage, frequency 120VAC, 60 Hz Load Rating Resistive Mechanical Switching Technology Relay Relay Triac Triac Relay Relay Single Pole/3-Way or Single Pole Single Pole Single Pole Single Pole/3-Way Single Pole/3-Way Single Pole/3-Way Single Pole/3-Way 180°, 900 Sq. Ft. Coverage • • • • • • Passive Infrared Sensing Technology • • • • • • 30s, 5m, 15m, 30m Time Delay • • • • • • Ambient Light Override • Auto/Manual ON • • Auto ON Manual ON Auto ON Manual ON Auto ON Manual ON • • • • • • Certifications UL CA Title 24 Code Compliance CA Title 20 Code Compliance* • • • • • • • • • Operating Temperature 0°C to 40°C • • • • • • Relative Humidity 20% to 90% noncondensing • • • • • • Storage Temperature -10°C to 85°C • • • • • • Environmental *Items meet California Code of Regulation Title 20, required Feb. 1, 2013 Universal Occupancy/Vacancy Sensors Features PRODUCT SPECIFICATIONS Wiring Diagrams IPS05/IPV05 IPVD6/IPSD6 Hot (Black) Black Sensor Sensor Hot (Black) Sensor 3-Way Switch Sensor Sensor Hot (Black) Pigtail Pigtail LINE/Black Use Terminal for 3-Way Applications Only. For Single Pole Applications, Do Not Remove This Label. Green Ground Line 120VAC, 60 Hz Red Green Ground Pigtail Line 120VAC 60 Hz LOAD Sensor Hot (Black) Pigtail Line 120VAC 60 Hz 3-Way/ Brass LOAD Common Terminal (Black Screw) Green Ground Line 120VAC 60 Hz LOAD/Red LO AD Black Sensor First Traveler Hot (Black) BK Pigtail 3-Way YL/R LOAD Common Terminal (Black Screw) G G LOAD Use Terminal for 3-Way Applications Only. For Single Pole Applications, Do Not Remove This Label. White Neutral (White) Pigtail Green Ground White RD (unused) Black Line 120 VAC, 60Hz Sensor LINE/Black LOAD BK (unu 3-Way Switch Sensor LOAD/Red Black WH Green Ground 3-Way/ Brass RD Second Traveler White WH Universal Occupancy/Vacancy Sensors Pigtail Neutral (White) Line 120VAC 60 Hz Common Terminal (Black Screw) Switch Remo WH Green Ground LOAD First Traveler Neutral (White) LINE/Black First Traveler 3-Way Switch Sensor IPS15/IPV15 White LO AD White Neutral (White) Second Traveler LOAD 3-Way/ Brass Second Traveler LINE/Black Green Ground LOAD/ Red Black 3-Way/ Brass Black LOAD/Red LO AD Pigtail Green Ground Neutral (White) LINE/Black Green Ground Red First Traveler Pigtail Green Ground Green Ground Line 120VAC 60 Hz Neutral (White) 3-Way Switch Sensor Hot (Black) 3-Way/ Brass LOAD/ Red Common Terminal (Black Screw) Neutral (White) erminal for 3-Way cations Only. ngle Pole Applications, t Remove This Label. Green Ground Second Traveler White Hot (Black) LINE/Black Green Ground Line 120VAC, 60 Hz Black 3-Way (Brass Screw) 3-Way Switch Sensor Hot (Black) (Black) Green Ground Switch Remote Sensor Hot (Black) BK WH Pigtail Green Ground 3-Way/ RD 3-Way Brass Second Traveler LOAD LOAD WH Green Ground Black Line 120 VAC, 60Hz Common TerminalApplications Only. Use Terminal for 3-Way (Black Screw) For Single Pole Applications, First Traveler Do Not Remove This Label. Neutral (White) BK (unused) RD (unused) YL/RD BK Hot (Black) Green Ground RD 3-Way Line 120 VAC, 60Hz White Neutral (White) Neutral (White) Ordering Information: Description Rating (120VAC) Cat. No. Color Relay Vacancy Sensor, single pole, 180° Field of View, 900 sq. ft. coverage 600W Incand/FL Ballast 150W LED/CFL, 1/6 HP Motor IPV05 Z Relay Occupancy Sensor, single pole, 180° Field of View, 900 sq. ft. coverage 600W Incand/FL Ballast 150W LED/CFL, 1/6 HP Motor IPS05 Z Dimming Vacancy Sensor, single pole or 3-Way, 180° Field of View, 900 sq. ft. coverage 600W Incand 150W LED/CFL IPVD6 Z Dimming Occupancy Sensor, single pole or 3-Way, 180° Field of View, 900 sq. ft. coverage 600W Incand 150W LED/CFL IPSD6 Z Relay Vacancy Sensor, single pole or 3-Way, 180° Field of View, 900 sq. ft. coverage, neutral required 1800W Incand, 600W LED/CFL, 1800VA Magnetic Ballast, 1/2 HP IPV15 Z Relay Occupancy Sensor, single pole or 3-Way, 180° Field of View, 900 sq. ft. coverage, neutral required 1800W Incand, 600W LED/CFL, 1800VA Magnetic Ballast, 1/2 HP IPS15 Z For use with IPS15 or IPV15 Sensor IPV0R Z Sensor Remote, 120VAC, Manual-ON, Auto-OFF Z - Comes packaged with three colors: White, Ivory and Light Almond. Leviton Manufacturing Co., Inc. 201 North Service Road, Melville, NY 11747-3138 Telephone: 1-800-323-8920 FAX: 1-800-832-9538 Tech Line (8:30AM-7:00PM E.T. Monday-Friday): 1-800-824-3005 Visit our Website at: www.leviton.com/sensors © 2012 Leviton Manufacturing Co., Inc. All rights reserved. G-8761/G12-dp