Firewall® SR Thermocouple Extension Cable World Class Nuclear Cable Binder Tape Helically applied polyester Jacket Rockhide® braid* Single Pair Shielded (Silicone Rubber) Shield Helically applied, laminated aluminum/polyester tape shield Drain Wire Flexible strand, tin-coated copper Covering Glass braid Conductor Solid alloys, thermocouple extension grade Insulation Silicone rubber 125°C, 600 Volt Class 1E Nuclear Spec. RSS-9-008 Scope Features Firewall SR Thermocouple Extension ® • Nuclear qualified with a minimum 40-year thermal life expectancy at 125°C Cable is a silicone rubber insulated • Radiation resistant (up to 200 megarads) construction specifically designed for high temperature applications • Flame retardant within nuclear generating facilities. • Extremely flexible for installation ease It is intended for use in harsh and • Excellent circuit integrity during flame conditions demanding environments where • Full traceability temperature extremes preclude the use • Tin-coated copper conductors for improved terminations, corrosion of standard cables. It may be installed resistance and temperature endurance in trays, ducts, conduits or in confined • Easy strippability for installation ease spaces such as equipment housings. Designed for use on circuits where • Tin-coated copper conductors for improved terminations, corrosion shielding from external electrostatic resistance and temperature endurance interference is not required. • All singles pass a wet dielectric (tank) test prior to braid covering to verify electrical integrity • All cables have printed sequential footage markers for improved inven­tory control Performance Standards • Silicone rubber insulation in accordance with ICEA Standard S-19-81 • Class 1E qualified in accordance with IEEE-383 1974 and IEEE-323 (Rockbestos Report QR-8802) • Cable passes IEEE-383 1974 70,000 BTU/hr vertical tray flame test as modified by NRC Reg. Guide 1.131 • ANSI standard MC 96.1 • Cable passes ICEA 210,000 BTU/hr vertical tray flame test (Standard T-29-520) • Single conductors pass the vertical flame test specified in IEEE-383 1974 para. 2.5.6 (ICEA S-19-81 Section 6.19.6) • Quality Assurance program in accordance with 10 CFR 50 Appendix B Construction Conductor: Solid alloys per ANSI MC 96.1 (Exten­sion Grade, standard limits of error) Insulation: Proprietary heat, moisture and radiation resistant silicone rubber Covering: Glass braid with high temperature finish Pair Assembly: Two insulated and braided conductors twisted with a flexible strand, tin-coated copper drain wire and a helically applied aluminum/polyester laminated tape shield Circuit Identification: Individual single conductors color coded to ANSI requirements by means of colored braids Fillers: (Where required) Binder Tape: Helically applied polyester Overall Covering: Rockhide® braid* with high temperature finish (colors to ANSI standards by type) * Rockhide® is a proprietary blend of aramid and other high temperature synthetic fibers. A Marmon Wire & Cable / Berkshire Hathaway Company RSCC Wire & Cable LLC © 2012 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 • Tel: 860-653-8300 • Fax: 860-653-8301 • www.r-scc.com T-17 Firewall® SR Single Pair Shielded (Silicone Rubber) Thermocouple Extension Cable 125°C, 600 Volt Class 1E Nuclear Spec. RSS-9-008 Single Shielded Pair –16 AWG Solid Product Code I68-3143 I68-3144 I68-3145 I68-3146 Conductor Type Insulation Thickness (inch) (mm) Individual Braid Thickness (Mils) Single Conductor Diameter (inch) Drain Wire Size/Stranding Nominal Overall Braid Overall Diameter Thickness (inch) (mm) (Mils) Approximate Net Weight (Lbs/M') JX .030 .76 7.5 .13 18 AWG (16/s) 40 .35 8.89 50 EX .030 .76 7.5 .13 18 AWG (16/s) 40 .35 8.89 50 KX .030 .76 7.5 .13 18 AWG (16/s) 40 .35 8.89 50 TX .030 .76 7.5 .13 18 AWG (16/s) 40 .35 8.89 50 Single Conductor Diameter (inch) Drain Wire Size/Stranding Single Shielded Pair –18 AWG Solid Product Code I68-3139 I68-3140 I68-3141 I68-3142 Conductor Type Insulation Thickness (inch) (mm) Individual Braid Thickness (Mils) Nominal Overall Braid Overall Diameter Thickness (inch) (mm) (Mils) Approximate Net Weight (Lbs/M') JX .030 .76 7.5 .12 20 AWG (10/s) 40 .33 8.38 40 EX .030 .76 7.5 .12 20 AWG (10/s) 40 .33 8.38 40 KX .030 .76 7.5 .12 20 AWG (10/s) 40 .33 8.38 40 TX .030 .76 7.5 .12 20 AWG (10/s) 40 .33 8.38 40 A Marmon Wire & Cable / Berkshire Hathaway Company RSCC Wire & Cable LLC © 2012 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 • Tel: 860-653-8300 • Fax: 860-653-8301 • www.r-scc.com Firewall® SR Thermocouple Extension Cable World Class Nuclear Cable Multi-Unshielded Pairs With Overall Shield (Silicone Rubber) Shield Helically applied, laminated aluminum/polyester tape shield Binder Tape Helically applied polyester Jacket Rockhide® braid* Drain Wire Flexible strand, tin-coated copper Covering Glass braid Conductor Solid alloys, thermocouple extension grade Insulation Silicone rubber 125°C, 600 Volt Class 1E Nuclear Spec. RSS-9-008 Scope Features • Nuclear qualified with a minimum 40-year thermal life expectancy at 125°C • Radiation resistant (up to 200 megarads) • Extremely flame retardant • Extremely flexible for installation ease • Excellent circuit integrity during flame conditions • Full traceability • Tin-coated copper conductors for improved terminations, corrosion resistance and temperature endurance • Easy strippability for termination ease • Tin-coated copper conductors for improved terminations, corrosion resistance and temperature endurance • All singles pass a wet dielectric (tank) test prior to braid covering to verify electrical integrity • All cables have printed sequential footage markers for improved inven­tory control Firewall SR Thermocouple Extension Cable is a silicone rubber insulated construction specifically designed for high temperature applications within nuclear generating facilities. It is intended for use in harsh and demanding environments where temperature extremes preclude the use of standard cables. It may be installed in trays, ducts, conduits or in confined spaces such as equipment housings. Designed for use on circuits where shielding from external electrostatic interference is required but shielding between pairs is not critical. ® Performance Standards • Silicone rubber insulation in accordance with ICEA Standard S-19-81 • Class 1E qualified in accordance with IEEE-383 1974 and IEEE-323 (Rockbestos Report QR-8802) • Cable passes IEEE-383 1974 70,000 BTU/hr vertical tray flame test as modified by NRC Reg. Guide 1.131 • ANSI standard MC 96.1 • Cable passes ICEA 210,000 BTU/hr vertical tray flame test (Standard T-29-520) • Single conductors pass the vertical flame test specified in IEEE-383 1974 para. 2.5.6 (ICEA S-19-81 Section 6.19.6) • Quality Assurance program in accordance with 10 CFR 50 Appendix B Construction Conductor: Solid alloys per ANSI MC 96.1 (Exten­sion Grade, standard limits of error) Insulation: Proprietary heat, moisture and radiation resistant silicone rubber Covering: Glass braid with high temperature finish Pair Assembly: Two insulated and braided conductors twisted Cabling: Required number of pairs cabled together Circuit Identification: Individual pair single conductors color coded to ANSI requirements by means of colored braids with printed pair ­numbers on both singles for pair ­identification Fillers: (Where required) Shield System: Helically applied aluminum/polyester laminated tape shield in continuous contact with a flexible strand, tin-coated copper drain wire Binder Tape: Helically applied polyester Overall Covering: Rockhide® braid* with high temperature finish (colors to ANSI standards by type) * Rockhide® is a proprietary blend of aramid and other high temperature synthetic fibers. A Marmon Wire & Cable / Berkshire Hathaway Company RSCC Wire & Cable LLC © 2012 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 • Tel: 860-653-8300 • Fax: 860-653-8301 • www.r-scc.com T-19 Firewall® SR Multi-Unshielded Pairs With Overall Shield (Silicone Rubber) Thermocouple Extension Cable 125°C, 600 Volt Class 1E Nuclear Spec. RSS-9-008 16 AWG Solid Single Conductor Diameter (inch) Drain Wire Size/Stranding Overall Braid Thickness (Mils) Nominal Overall Diameter (inch) (mm) Approximate Net Weight (Lbs/M') Product Code* Number of Pairs Conductor Type* I68-3187 2 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .54 13.72 95 3 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .57 14.48 125 4 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .65 16.51 165 5 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .71 18.03 200 7 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .78 19.81 255 9 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .92 23.37 335 12 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.04 26.42 410 15 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.16 28.46 515 19 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.23 31.24 630 37 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.67 42.42 1190 Individual Conductor Diameter (inch) Single Conductor Diameter (inch) Drain Wire Size/Stranding Overall Braid Thickness (Mils) I68-3191 I68-3195 I68-3199 I68-3203 I68-3207 I68-3211 I68-3215 I68-3219 I68-3223 Insulation Thickness (inch) (mm) Individual Conductor Diameter (inch) 18 AWG Solid Approximate Net Weight (Lbs/M') Number of Pairs Conductor Type* I68-3147 2 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .50 12.70 75 3 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .53 13.46 100 4 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .60 15.24 130 5 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .66 16.76 160 7 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .72 18.29 200 9 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .85 21.59 260 12 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .96 24.38 315 15 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.07 27.18 400 19 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.13 28.70 485 37 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.54 39.12 915 I68-3151 I68-3155 I68-3159 I68-3163 I68-3167 I68-3171 I68-3175 I68-3179 I68-3183 Insulation Thickness (inch) (mm) Nominal Overall Diameter (inch) (mm) Product Code* * Product Code Sequence: Codes for other alloy combinations can be obtained by applying the following numbering sequence: Type Product Code EX KX TX Add “1” to above “JX” code Add “2” to above “JX” code Add “3” to above “JX” code Example: I68-3188 = 2 PAIR 16 AWG Type “EX” A Marmon Wire & Cable / Berkshire Hathaway Company RSCC Wire & Cable LLC © 2012 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 • Tel: 860-653-8300 • Fax: 860-653-8301 • www.r-scc.com Firewall® SR Thermocouple Extension Cable World Class Nuclear Cable Binder Tape Helically applied polyester Jacket Rockhide® braid* Multi-Shielded Pairs Without Overall Shield (Silicone Rubber) Shield Helically applied, laminated aluminum/polyester tape shield Isolation Tape Covering Glass braid Conductor Solid alloys, thermocouple extension grade 125°C, 600 Volt Class 1E Nuclear Insulation Silicone rubber Spec. RSS-9-008 Drain Wire Flexible strand, tin-coated copper Scope Features Firewall SR Thermocouple Extension Cable is a silicone rubber insulated construction specifically designed for high temperature applications within nuclear generating facilities. It is intended for use in harsh and demanding environments where temperature extremes preclude the use of standard cables. It may be installed in trays, ducts, conduits or in confined spaces such as equipment housings. Designed for use on circuits where shielding over individual pairs is required but additional overall shielding is not critical. ® • Nuclear qualified with a minimum 40-year thermal life expectancy at 125°C • Radiation resistant (up to 200 megarads) • Flame retardant • Extremely flexible for installation ease • Excellent circuit integrity during flame conditions • Full traceability • Tin-coated copper conductors for improved terminations, corrosion resistance and temperature endurance • Easy strippability for termination ease • All singles pass a wet dielectric (tank) test prior to braid covering to verify electrical integrity • Shield to shield isolation system provided and verified by electrical testing • All cables have printed sequential footage markers for improved inven­tory control Performance Standards • Silicone rubber insulation in accordance with ICEA Standard S-19-81 • Class 1E qualified in accordance with IEEE-383 1974 and IEEE-323 (Rockbestos Report QR-8802) • Cable passes IEEE-383 1974 70,000 BTU/hr vertical tray flame test as modified by NRC Reg. Guide 1.131 • ANSI standard MC 96.1 • Cable passes ICEA 210,000 BTU/hr vertical tray flame test (Standard T-29-520) • Single conductors pass the vertical flame test specified in IEEE-383 1974 para. 2.5.6 (ICEA S-19-81 Section 6.19.6) • Quality Assurance program in accordance with 10 CFR 50 Appendix B Construction Conductor: Solid alloys per ANSI MC 96.1 (Exten­sion Grade, standard limits of error) Insulation: Proprietary heat, moisture and radiation resistant silicone rubber Covering: Glass braid with high temperature finish Pair Assembly: Two insulated and braided conductors twisted with a flexible strand, tin-coated copper drain wire, a helically applied aluminum/polyester laminated tape shield and an isolation tape Cabling: Required number of pairs cabled together Circuit Identification: Individual pair single conductors color coded to ANSI requirements by means of colored braids with printed pair numbers on both singles for pair identification Fillers: (Where required) Binder Tape: Helically applied polyester Overall Covering: Rockhide® braid* with high temperature finish (colors to ANSI standards by type) * Rockhide® is a proprietary blend of aramid and other high temperature synthetic fibers. A Marmon Wire & Cable / Berkshire Hathaway Company RSCC Wire & Cable LLC © 2012 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 • Tel: 860-653-8300 • Fax: 860-653-8301 • www.r-scc.com T-21 Firewall® SR Multi-Shielded Pairs Without Overall Shield (Silicone Rubber) Thermocouple Extension Cable 125°C, 600 Volt Class 1E Nuclear Spec. RSS-9-008 16 AWG Solid Single Conductor Diameter (inch) Drain Wire Size/Stranding Overall Braid Thickness (Mils) Nominal Overall Diameter (inch) (mm) Approximate Net Weight (Lbs/M') Product Code* Number of Pairs Conductor Type* I68-3267 2 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .58 14.73 110 3 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .61 15.49 145 4 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .68 17.27 190 5 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .75 19.05 235 7 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .82 20.83 305 9 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .97 24.64 410 12 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.10 27.94 490 15 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.24 31.50 620 19 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.31 33.27 765 37 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.89 48.01 1480 Individual Conductor Diameter (inch) Single Conductor Diameter (inch) Drain Wire Size/Stranding Overall Braid Thickness (Mils) I68-3271 I68-3275 I68-3279 I68-3283 I68-3287 I68-3291 I68-3295 I68-3299 I68-3303 Insulation Thickness (inch) (mm) Individual Conductor Diameter (inch) 18 AWG Solid Approximate Net Weight (Lbs/M') Number of Pairs Conductor Type* I68-3227 2 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .54 13.72 85 3 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .57 14.48 115 4 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .63 16.00 145 5 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .69 17.53 180 7 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .76 19.30 235 9 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .90 22.86 305 12 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.02 25.91 375 15 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.15 29.21 475 19 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.21 30.73 585 37 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.67 42.42 1115 I68-3231 I68-3235 I68-3239 I68-3243 I68-3247 I68-3251 I68-3255 I68-3259 I68-3263 Insulation Thickness (inch) (mm) Nominal Overall Diameter (inch) (mm) Product Code* * Product Code Sequence: Codes for other alloy combinations can be obtained by applying the following numbering sequence: Type Product Code EX KX TX Add “1” to above “JX” code Add “2” to above “JX” code Add “3” to above “JX” code Example: I68-3268 = 2 PAIR 16 AWG Type “EX” A Marmon Wire & Cable / Berkshire Hathaway Company RSCC Wire & Cable LLC © 2012 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 • Tel: 860-653-8300 • Fax: 860-653-8301 • www.r-scc.com Firewall® SR Thermocouple Extension Cable World Class Nuclear Cable Jacket Rockhide® braid* Multi-Shielded Pairs With Overall Shield (Silicone Rubber) Shield Helically applied, laminated aluminum/polyester tape shield Binder Tape Helically applied polyester Isolation Tape Drain Wire Flexible strand, tin-coated copper Covering Glass braid Conductor Solid alloys, thermocouple extension grade Insulation Silicone rubber 125°C, 600 Volt Class 1E Nuclear Spec. RSS-9-008 Scope Features • Nuclear qualified with a minimum 40-year thermal life expectancy at 125°C • Radiation resistant (up to 200 megarads) • Flame retardant • Extremely flexible for installation ease • Excellent circuit integrity during flame conditions • Full traceability • Tin-coated copper conductors for improved terminations, corrosion resistance and temperature endurance • Easy strippability for installation ease • All singles pass a wet dielectric (tank) test prior to braid covering to verify electrical integrity • Shield to shield isolation system provided and verified by electrical testing • All cables have printed sequential footage markers for improved inven­tory control Firewall SR Thermocouple Extension Cable is a silicone rubber insulated construction specifically designed for high temperature applications within nuclear generating facilities. It is intended for use in harsh and demanding environments where temperature extremes preclude the use of standard cables. It may be installed in trays, ducts, conduits or in confined spaces such as equipment housings. Designed for use on critical circuits where complete isolation is required between pairs and from external interference. ® Performance Standards • Silicone rubber insulation in accordance with ICEA Standard S-19-81 • Class 1E qualified in accordance with IEEE-383 1974 and IEEE-323 (Rockbestos Report QR-8802) • Cable passes IEEE-383 1974 70,000 BTU/hr vertical tray flame test as modified by NRC Reg. Guide 1.131 • ANSI standard MC 96.1 • Cable passes ICEA 210,000 BTU/hr vertical tray flame test (Standard T-29-520) • Single conductors pass the vertical flame test specified in IEEE-383 1974 para. 2.5.6 (ICEA S-19-81 Section 6.19.6) • Quality Assurance program in accordance with 10 CFR 50 Appendix B Construction Conductor: Solid alloys per ANSI MC 96.1 (Exten­sion Grade, standard limits of error) Insulation: Proprietary heat, moisture and radiation resistant silicone rubber Covering: Glass braid with high temperature finish Pair Assembly: Two insulated and braided conductors twisted with a flexible strand, tin-coated copper drain wire, a helically applied aluminum/polyester laminated tape shield and an isolation tape Cabling: Required number of pairs cabled together Circuit Identification: Individual pair single conductors color coded to ANSI requirements by means of colored braids with printed pair numbers on both singles for pair identification Fillers: (Where required) Shield System: Helically applied aluminum/polyester laminated tape shield in continuous contact with a flexible strand, tin coated copper drain wire Binder Tape: Helically applied polyester Overall Covering: Rockhide® braid* with high temperature finish (colors to ANSI standards by type) * Rockhide® is a proprietary blend of aramid and other high temperature synthetic fibers. A Marmon Wire & Cable / Berkshire Hathaway Company RSCC Wire & Cable LLC © 2012 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 • Tel: 860-653-8300 • Fax: 860-653-8301 • www.r-scc.com T-23 Firewall® SR Multi-Shielded Pairs With Overall Shield (Silicone Rubber) Thermocouple Extension Cable 125°C, 600 Volt Class 1E Nuclear Spec. RSS-9-008 16 AWG Solid Single Conductor Diameter (inch) Drain Wire Size/Stranding Overall Braid Thickness (Mils) Nominal Overall Diameter (inch) (mm) Approximate Net Weight (Lbs/M') Product Code* Number of Pairs Conductor Type* I68-3347 2 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .58 14.73 115 3 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .62 15.75 150 4 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .71 18.03 200 5 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .78 19.81 245 7 JX .030 .76 7.5 .13 18 AWG (16/s) 40 .85 21.59 315 9 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.00 25.45 425 12 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.13 28.70 505 15 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.27 32.36 635 19 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.34 34.04 780 37 JX .030 .76 7.5 .13 18 AWG (16/s) 40 1.94 49.28 1500 Individual Conductor Diameter (inch) Single Conductor Diameter (inch) Drain Wire Size/Stranding Overall Braid Thickness (Mils) I68-3351 I68-3355 I68-3359 I68-3363 I68-3367 I68-3371 I68-3375 I68-3379 I68-3383 Insulation Thickness (inch) (mm) Individual Conductor Diameter (inch) 18 AWG Solid Approximate Net Weight (Lbs/M') Number of Pairs Conductor Type* I68-3307 2 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .54 13.72 90 3 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .58 14.73 120 4 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .66 16.76 155 5 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .72 18.29 190 7 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .79 20.07 245 9 JX .030 .76 7.5 .12 20 AWG (10/s) 40 .93 23.62 315 12 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.05 26.67 390 15 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.17 29.72 490 19 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.24 31.50 595 37 JX .030 .76 7.5 .12 20 AWG (10/s) 40 1.69 42.93 1130 I68-3311 I68-3315 I68-3319 I68-3323 I68-3327 I68-3331 I68-3335 I68-3339 I68-3343 Insulation Thickness (inch) (mm) Nominal Overall Diameter (inch) (mm) Product Code* * Product Code Sequence: Codes for other alloy combinations can be obtained by applying the following numbering sequence: Type Product Code EX KX TX Add “1” to above “JX” code Add “2” to above “JX” code Add “3” to above “JX” code Example: I68-3348 = 2 PAIR 16 AWG Type “EX” A Marmon Wire & Cable / Berkshire Hathaway Company RSCC Wire & Cable LLC © 2012 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 • Tel: 860-653-8300 • Fax: 860-653-8301 • www.r-scc.com