UnderwaterCables In Stock

advertisement
 







MacArtney Underwater Cables - In stock
The MacArtney Group depends on the support of a number of major cable manufacturers to supply
a range of cables that are designed, manufactured and tested to meet the highest demands of the
stock while other cables are manufactured to order. Quality is maintained to the highest standard in the
industry. MacArtney also supplies engineering services and components to integrate total cable solution
packages.
For further information please visit: www.macartney.com
Index
TV-Cables (04 - 09)
The standard TV cables contain a range of custom designed multi conductor cables for
use with underwater TV systems and other equipment. These cables contain a variety of
coaxes, twisted pairs and power conductors to allow cameras, lights and pan & tilt units
to be powered, controlled and video images carried to the surface. The cables all have
Polyurethane outer jackets, allowing them to be easily moulded to connectors to make
underwater cable harness assemblies.
Combined Power/Signal Cables (10 - 15)
Cables in this section contain a mixture of power conductors and shielded twisted pairs
cabled together within a Polyurethane outer jacket. From the simple, two power conductors
and one shielded pair, to the more complex cables, there is bound to be a cable that will
meet your needs. These cables are ideal for the construction of harness assemblies for
transmission of data from point to point.
Instrumentation Cables (16 - 25)
The instrumentation cables contain a number of cables for a variety of purposes. From
one shielded twisted pair to several shielded twisted pairs or single conductors with overall
shield. Cables in this section have Polyurethane outer jacket, allowing them to be easily
moulded to connectors to make underwater cable harness assemblies.
Fibre Optic Cables (26 - 30)
in these cables has undergone many years of development and has a long track record
of successful operation down to 6000 meters water depth. The individual elements are
combined and packaged within a Polyurethane outer jacket providing additional protection
range.
Special Cables (31 - 32)
Our program for these cables covers most of the market demands. These include long steel
armoured tow cables for sophisticated military arrays to short lengths of instrument cables
for CTD probes. Fibre optic cables are playing an increasingly important role in this section
of the market and our in-house engineering can support our customers with cable and
termination designs and advise on tow characteristics etc.
Non Stock Cables (33)
Sonar & Acoustic System Cables
Video System Umbilicals
ROV and Trencher Umbilicals
Dynamic Cable Ancilliary Products
Terminations (34 - 35)
Our standard shackle or fork terminations are safe and reliable methods of connecting cable
to towed underwater vehicles or for lifting a heavy object, such as a down-hole camera
system. Terminating and moulding the cable to a connector ensures a watertight connection
from cable to system. MacArtney stocks standard terminations for steel armoured or Kevlar
armoured cables with diameters of 6 to 14mm and loads of up to 1500kg. We also have
extensive experience of designing terminations for loads of up to 100 tonnes.
TV cables
Micro TV cable - Type 6075
Coax
75 ohm coax (1 ea.)
Conductors
1,00 mm2 bare copper conductor insulated with PE (2 ea.)
Shield
Aluminium/polyester foil and tinned copper drain wire, coverage 100%
Outer jacket
Polyurethane jacket. Colour orange
Diameter
7,50 mm ±0,25 mm
Weight in air
73 kg/ km nom.
Weight in seawater
28 kg/ km nom.
Min. bending radius, static
50 mm
Min. bending radius, dynamic
60 mm
Depth rating
5000 m
Operating voltage
600 V for conductors
Test voltage
1500 V DC for 1 min.
Conductor resistance
250,0 ohm/ km for coax
20,0 ohm/ km for conductors
Insulation resistance
5000 Mohm* km
Capacitance
59 pF/ m for coax
Attenuation
4,30 dB/ 100 m at 5 MHz for coax
6.50 dB/ 100 m at 10 MHz for coax
13.80 dB/ 100 m at 50 MHz for coax
18.60 dB/ 100 m at 100 MHz for coax
67.11 dB/ 100 m at 1000 MHz for coax
04
No. 2004727C - Rev C - 02/12
TV cables
Mini TV Cable - Type 6011
Coax
75 ohm coax (1 ea.)
Conductor
1,34 mm2 bare copper conductor insulated with PE (1 ea.)
Shielded twisted pair
0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (1 ea.)
Shielded twisted pair
1,34 mm2 bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (1 ea.)
Twisted pair
0,22 mm2 tinned copper conductor insulated with PE. Two conductors twisted
together (1 ea.)
Filling compound
The cable is filled with cable filling compound
Shield
Aluminium/polyester foil and tinned copper drain wire, coverage 100%
Outer jacket
Polyurethane jacket. Colour orange
Diameter
11,00 mm ±0,50 mm
Weight in air
165 kg/km nom.
Weight in seawater
70 kg/km nom.
Min. bending radius, static
100 mm
Min. bending radius, dynamic
145 mm
Depth rating
5000m
Operating voltage
600 V for 1,34 mm and 0,50 mm conductors
24 V for 0,22 mm2 conductors
2
2
Conductor resistance
135,0 ohm/km for coax
15,3 ohm/km for 1,34 mm2 conductors
41,0 ohm/km for 0,50 mm2 conductors
2
96,2 ohm/km for 0,22 mm conductors
Insulation resistance
5000 Mohm*km for coax, 1,34 mm2 and 0,22 mm2 conductor
10000 Mohm*km for 1,34 mm2 and 0,50 mm2 conductors (cond./cond.)
100 Mohm*100 m for 1,34 mm2 and 0,50 mm2 conductors (cond./shield)
Capacitance
59 pF/m for coax
155 pF/m for 1,34 mm2 pair
107 pF/m for 0,50 mm2 pair
2
57 pF/km for 0,22 mm pair
Impedance
37 ± 5 Ohm at 1-10 MHz for 1.34 mm² pair
52 ± 5 Ohm at 1-10 MHz for 0.50 mm² pair
73 ± 5 Ohm at 1-10 MHz for 0.22 mm² pair
Attenuation
7.0 dB/100m at 1 MHz for 1.34 mm², 0.50 mm² and 0.22 mm² pair
17.5 dB/100m at 10 MHz for 1.34 mm² pair
18.0 dB/100m at 10 MHz for 0.50 mm² and 0.22 mm² pair
No. 2000543C - Rev G - 02/12
05
TV cables
Kelvar TV cable - Type 6926
Coax
75 ohm coax (1 ea.)
Conductors
1,00 mm2 bare copper conductor insulated with PE (8 ea.)
Shielded twisted quint
0,14 mm2 tinned copper conductors insulated with PE. Five conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (1 ea.)
Shielded twisted quad
0,22 mm2 tinned copper conductors insulated with PE. Four conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (1 ea.)
Filling compound
The cable is filled with cable filling compound
Strength member
Kevlar braid.
Outer jacket
Polyurethane jacket. Colour red
Diameter
14,40 mm ±0,50 mm
Weight in air
275 kg/ km nom.
Weight in seawater
108 kg/ km nom.
Min. bending radius, static
100 mm
Min. bending radius, dynamic
200 mm
Min. breaking strength
7 kN
Depth rating
5000 m
Operating voltage
600 V for 1,00 mm2 conductors
2
2
24 V for 0,22 mm and 0,14 mm conductors
Test voltage
1500 V DC for 1 min. for coax, 0,22 mm2 and 0,14 mm2 conductor
2
3000 V DC for 1 min. for 1,00 mm conductor
Conductor resistance
89,5 ohm/ km for coax
20,0 ohm/ km for 1,00 mm2 conductor
96,2 ohm/ km for 0,22 mm2 conductor
2
145,0 ohm/ km for 0,14 mm conductor
Insulation resistance
5000 Mohm* km
Capacitance
67 pF/ m for coax
2
80 pF/ m for 0,22 mm quad
2
65 pF/ m for 0,14 mm quint
Impedance
75 ± 3 Ohm at 1 MHz for coax
Attenuation
2.5 dB/100m at 5 MHz for coax
12.20 dB/100m at 100 MHz for coax
41.50 dB/100m at 1000 MHz for coax
06
No. 2002621C - Rev. G - 02/12
TV cables
TV Cable with 2 coaxes - Type 6120/B
Coax
75 ohm coax (2 ea.)
Twisted quad
0,50 mm2 bare copper conductors insulated with PE. Four conductors
twisted together (1 ea.)
Shielded twisted pairs
1,34 mm2 bare copper conductors insulated with PE. Two conductors
twisted together with a tinned copper drain wire and aluminium/polyester foil (4 ea.)
Filling compound
The cable is filled with cable filling compound
Outer jacket
Polyurethane jacket. Colour orange
Diameter
14,80 mm ±0,20 mm
Weight in air
340 kg/km nom.
Weight in seawater
165 kg/km nom.
Min. bending radius, static
170 mm
Min. bending radius, dynamic
225 mm
Depth rating
5000 m
Operating voltage
600 V
Test voltage
1500 V DC for 1 min. for coax
3000 V DC for 1 min. for 0,50 mm2 and 1,34 mm2 conductors
Conductor resistance
89,5 ohm/ km for coax
41,0 ohm/ km for 0,50 mm2 conductor
2
15,3 ohm/ km for 1,34 mm conductor
Insulation resistance
5000 Mohm* km
Capacitance
56 pF/ m for coax
50 pF/ m for 0,50 mm2 quad
2
190 pF/ m for 1,34 mm pair
Impedance
37 ± 5 Ohm at 1-10 MHz for 1,34 mm² pair
Attenuation
3.00 dB/ 100 m at 5 MHz for coax
4.30 dB/ 100 m at 10 MHz for coax
44.3 dB/ 100 m at 1000 MHz for coax
7.0 dB/ 100 m at 1 MHz for twisted pair
17.5 dB/ 100 m at 10 MHz for twisted pair
07
No. 2000575
1C - Rev. C. - 02/12
TV cables
TV cable with 3 coaxes - Type 6130
Coax
75 ohm coax (3 ea.)
Shielded twisted pairs
0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire, aluminium/polyester foil and a PE sheath
(3 ea.)
Conductor
1,00 mm bare copper conductor insulated with PE (2 ea.)
Filling compound
The cable is filled with cable filling compound
Outer jacket
Polyurethane jacket. Colour blue
Diameter
14,00 mm ±0,50 mm
Weight in air
260 kg/ km nom.
Weight in seawater
98 kg/ km nom.
Min. bending radius, static
90 mm
Min. bending radius, dynamic
135 mm
Depth rating
5000 m
Operating voltage
600 V
Test voltage
1500 V DC for 1 min. for coax
2
2
3000 V DC for 1 min. for 1,00 mm and 0,50 mm conductors
2
Conductor resistance
135,0 ohm/ km for coax
20,0 ohm/ km for 1,00 mm2 conductors
2
41,0 ohm/ km for 0,50 mm conductors
Insulation resistance
5000 Mohm* km for coax and 1,00 mm conductors
2
10000 Mohm* km for 0,50 mm conductors (cond./cond.)
100 Mohm*100 m for 0,50 mm2 conductors (cond./shield)
2
Capacitance
59 pF/ m for coax
2
107 pF/ m for 0,50 mm pair
Impedance
52 ± 5 Ohm at 1-10 MHz for 0.50 mm² pair
Attenuation
3,79 dB/ 100 m at 5 MHz for coax
5.32 dB/ 100 m at 10 MHz for coax
17.44 dB/ 100 m at 100 MHz for coax
67.11 dB/ 100 m at 1000 MHz for coax
7.0 dB/ 100 m at 1 MHz for 0,55 mm² pair
18.0 dB/ 100 at 10 MHz for 0.55 mm² pair
08
No. 2002623C - Rev. F - 02/12
TV cables
Special TV cable - Type 6013/B
Coax
75 ohm coax (1 ea.)
Conductors
2,00 mm2 bare copper conductor insulated with PE (2 ea.)
Shielded twisted pair
0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil. (1 ea.)
Shielded twisted quad
0,22 mm2 bare copper conductor insulated with PE. Four conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil. (1 ea.)
Twisted pairs
1,34 mm2 bare copper conductor insulated with PE. Two conductors twisted
together. (2 ea.)
Filling compound
The cable is filled with cable filling compound
Shield
Aluminium/polyester foil and tinned copper drain wire, coverage 100%
Outer jacket
Polyurethane jacket. Colour yellow
Diameter
14,50 mm ±0,40 mm
Weight in air
255 kg/ km nom.
Weight in seawater
86 kg/ km nom.
Min. bending radius, static
150 mm
Min. bending radius, dynamic
215 mm
Depth rating
5000 m
Operating voltage
600 V for 0,50 mm2, 2,00 mm2 and 1,34 mm2 conductors
24 V for 0,22 mm2 conductors
Conductor resistance
135 ohm/ km for coax
2
10,0 ohm/ km for 2,00 mm conductors
2
41,0 ohm/ km for 0,50 mm conductors
96,2 ohm/ km for 0,22 mm2 conductors
2
15,3 ohm/ km for 1,34 mm conductors
Insulation resistance
5000 Mohm* km for coax, 2,00 mm2 conductors and 1,34 mm2 conductors
2
2
10000 Mohm* km for 0,50 mm conductors and 0,22 mm conductors
Capacitance
59 pF/ m for coax
2
2
80 pF/ m for 0,50 mm and 1,34 mm pair
65 pF/ m for 0,22 mm2 quad
Attenuation
3.79 dB/ 100 m at 5 MHz for coax
5.32 dB/ 100 m at 10 MHz for coax
67.11 dB/ 100 m at 1000 MHz for coax
No. 2005741C - Rev. C - 02/12
09
Combined power / signal cables
Seismic cable - Type 2009/B
2
Power conductors
2,00 mm bare copper conductor insulated with PVC (2 ea.)
Shielded twisted pair
0,22 mm bare copper conductor insulated with PE. Two conductors twisted
Together with a tinned copper drain wire and aluminium/ polyester foil. (2 ea.)
Inner jacket
PVC jacket
Outer jacket
Polyurethane jacket. Colour blue
Diameter
9,00 mm ±0,30 mm
Weight in air
125 kg/ km nom.
Weight in seawater
60 kg/ km nom.
Min. bending radius, static
100 mm
Min. bending radius, dynamic
130 mm
Depth rating
3000 m
Operating voltage
600 V for 2,00 mm conductors
24 V for 0,22 mm2 conductors
Test voltage
3000 V DC for 1 min. for 2,00 mm2 conductors (cond./cond.)
2
1500 V DC for 1 min. for 0,22 mm conductors (cond./cond.)
2
2
2
Conductor resistance
10,0 ohm/ km for 2,00 mm conductors
2
96,2 ohm/ km for 0,22 mm conductors
Insulation resistance
100 Mohm* km for 2,00 mm2 conductors
5000 Mohm* km for 0,22 mm2 conductors
2
Capacitance
70 pF/ m for 0,22 mm pair
Characteristic impedance
58 ± 5 Ohm at 1-10 MHz
Attenuation at 1 MHz
Attenuation at 10 MHz
10.0 dB/ 100 m
25.0 dB/ 100 m
10
No. 2005742C - Rev. C - 02/12
Combined power / signal cables
Seismic cable with kelvar - Type 2019/B
Power conductors
2,00 mm2 bare copper conductor insulated with PVC (2 off)
Shielded twisted pair
0,22 mm bare copper conductor insulated with PE. Two conductors twisted
Together with a tinned copper drain wire and aluminium/ polyester foil. (2 off)
Inner jacket
PVC jacket
Inner jacket
Polyurethane jacket
Strength member
Braided Kevlar
Outer jacket
Polyurethane jacket. Colour blue
Operating temperature range
-20 C to 80 C
Diameter
14,30 mm ±0,30 mm
Weight in air
220 kg/ km nom.
Weight in seawater
55 kg/ km nom.
Min. breaking strength
1500 kg
Min. bending radius, static
160 mm
Min. bending radius, dynamic
210 mm
Depth rating
5000 m
Operating voltage
600 V for 2,00 mm2 conductors
2
24 V for 0,22 mm conductors
Test voltage
3000 V DC for 1 min. for 2,00 mm2 conductors (cond./cond.)
2
1500 V DC for 1 min. for 0,22 mm conductors (cond./cond.)
2
Conductor resistance
10,0 ohm/ km for 2,00 mm2 conductors
2
96,2 ohm/ km for 0,22 mm conductors
Insulation resistance
100 Mohm* km for 2,00 mm2 conductors
2
5000 Mohm* km for 0,22 mm conductors
Capacitance
70 pF/m for 0,22 mm2 pair
Characteristic impedance
60 ± 5 Ohm for 0,22 mm² pair
Attenuation
10,0 dB/ 100 m at 1 MHz
25,0 dB/ 100 m at 10 MHz
11
No. 2005743C -Rev. D - 02/12
Combined power / signal cables
Combined power / signal cable - Type 4591
Shielded twisted triad
1,50 mm2 bare copper conductor insulated with PE. Three conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (1 ea.)
Shielded twisted pairs
0,50 mm bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (8 ea.)
Filling compound
The cable is filled with cable filling compound
Outer jacket
Polyurethane jacket. Colour black
Diameter
19,00 mm ±0,50 mm
Weight in air
460 kg/km nom.
Weight in seawater
170 kg/km nom.
Min. bending radius, static
125 mm
Min. bending radius, dynamic
185 mm
Depth rating
5000 m
Operating voltage
1000 V DC for 1,50 mm2 conductors
2
600 V DC for 0,50 mm conductors
Test voltage
4000 V DC for 1 min. for 1,50 mm conductor
3000 V DC for 1 min. for 0,50 mm2 conductor
2
2
Conductor resistance
13,7 ohm/ km for 1,50 mm2 conductor
41,0 ohm/ km for 0,50 mm2 conductor
Insulation resistance
10000 Mohm* km (cond./shield)
100 Mohm* 100 m (shield/shield)
Capacitance
80 pF/m for 1,50 mm2 triad
100 pF/m for 0,50 mm2 pair
Impedance
57 ± 5 Ohm for 0,5 mm² pair
Attenuation
7.0 dB/ 100 m at 1 MHz
18.0 dB/ 100 m at 10 MHz
12
No. 2002626C - Rev. F - 02/12
Combined power / signal cables
Combined power / signal cable - Type 4622
Power conductors
1,00 mm2 bare copper conductor insulated with PE. (2 ea.)
Shielded twisted pairs
0,22 mm bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire, aluminium/polyester foil and a PE sheath
(1 ea.)
Shielded twisted pairs
0,22 mm2 bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire and a aluminium/polyester foil (5 ea.)
Shield
Tinned copper braid, coverage 85%
Outer jacket
Polyurethane jacket. Colour blue
Diameter
12,00 mm ±0,40 mm
Weight in air
200 kg/km nom.
Weight in seawater
110 kg/km nom.
Min. bending radius, static
80 mm
Min. bending radius, dynamic
120 mm
Depth rating
3000 m
Operating voltage
600 V DC for 1,00 mm2 conductors
24 V DC for 0,22 mm2 conductors
Test voltage
3000 V DC for 1 min. for 1,00 mm2 conductor
1500 V DC for 1 min. for 0,22 mm2 conductor
Conductor resistance
2
20,0 ohm/km for 1,00 mm2 conductor
96,2 ohm/km for 0,22 mm2 conductor
Insulation resistance
> 100 Mohm* km (cond./cond.)
> 50 Mohm* km (cond./shield)
> 10 Mohm* km (shield/shield)
Capacitance
85 pF/ m for 0,22 mm2 pair
Impedance
60 ± 5 Ohm at 1-10 MHz for 0,22 mm² pair
Attenuation
10.0 dB/ 100 m at 1 MHz
25.0 dB/ 100 m at 10 MHz
13
No. 2005745C - Rev. C - 02/12
Combined power / signal cables
Combined power / signal cable - Type 4971
Power conductors
2,50 mm2 bare copper conductor insulated with PE. (2 off)
Shielded twisted pair
0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (1 off)
Outer jacket
Polyurethane jacket. Colour orange
Operating temperature range
-20 C to 80 C
Diameter
11,00 mm ±0,30 mm
Weight in air
160 kg/ km nom.
Weight in seawater
65 kg/ km nom.
Min. bending radius, static
130 mm
Min. bending radius, dynamic
165 mm
Depth rating
3000 m
Operating voltage
600 V DC for 2,50 mm2 conductors
2
300 V DC for 0,50 mm conductors
Test voltage
4000 V DC for 1 min. for 2,50 mm2 conductors
2
3000 V DC for 1 min. for 0,50 mm conductors
Conductor resistance
8,0 ohm/ km for 2,50 mm2 conductors
2
41,0 ohm/ km for 0,50 mm conductors
Insulation resistance
5000 Mohm* km for 2,50 mm2 conductors
2
10000 Mohm* km for 0,50 mm conductors (cond./cond.)
100 Mohm* 100 m for 0,50 mm2 conductors (cond./shield)
2
Capacitance
100 pF/m for 0,50 mm pai
rat800–1200Hznom.
Characteristic impedance (1-10 MHz)
57 ± 5 Ohm for 0,50 mm² conductors
Attenuation
7.0 dB/ 100 m at 1 MHz
18.0 dB/ 100 m at 10 MHz
14
No. 2005747C - Rev. B - 02/12
Combined power / signal cables
Light weight sonar cable - Type 5025
Construction Characteristics
2
Inner Conductor
0,50 mm stranded bare copper conductor (7 ea.)
Dielectric
Foam polyolefin
1st Shield
Tinned copper braid, coverage
85%
2nd Shield
Tinned copper braid, coverage
85%
Inner jacket
Polyurethane jacket
Strength member
Aramidic yarn braid
Outer jacket
Polyurethane jacket. Colour yellow
Mechanical Characteristics
Diameter
9,7 mm ±0,3 mm
Weight in air
135 kg/ km nom.
Weight in seawater
58 kg/ km nom.
Strength member Breaking Load
25 kN
Strength member Safe Working load
6 kN
Min. bending radius
90 mm
Depth rating
5000 meters
Electrical Characteristics
Operating voltage
400 V
Test voltage
2000 V DC for 1 min.
Conductor resistance
14,5 ohm/ km
Insulation resistance
5 ohm/ km
Impedance
50 ohm ± 3 ohm
Capacitance
94 pF/ m
Attenuation
10 dB/ km at 1 MHz
15
No. 2009880C - Rev. B - 02/12
Instrumentation cables
1 STP Data Cable - Type 4021
Shielded twisted pair
1,00 mm2 bare copper conductor insulated with PE. Two conductors twisted
together with a bare copper drain wire and aluminium/ polyester foil (1 ea.)
Outer jacket
Polyurethane jacket. Colour blue
Diameter
8,00 mm ±0,30 mm
Weight in air
76 kg/ km nom.
Weight in seawater
33 kg/ km nom.
Min. bending radius, static
95 mm
Min. bending radius, dynamic
120 mm
Depth rating
3000 m
Operating voltage
750 V
Test voltage
4000 V DC for 1 min.
Conductor resistance
20,0 ohm/ km
Insulation resistance
500 Mohm* km (cond./cond.)
10 Mohm* 100 m (cond./shield)
Capacitance
85 pF/ m nom.
Impedance
65 ± 5 Ohm at 1-10 MHz
Attenuation
4.5 dB/ 100 m at 1 MHz
11.5 dB/ 100 m at 10 MHz
16
No. 2005744C - Rev. B - 02/12
Instrumentation cables
4 STP Data cable- Type 4588
Centre filler
Textile filler
Shielded twisted pairs
1,00 mm2 bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire and aluminium/ polyester foil (4 ea.)
Filling compound
The cable is filled with cable filling compound
Shield
Aluminium/polyester foil and tinned copper drain wire, coverage 100%
Outer jacket
Polyurethane jacket. Colour black
Diameter
14,00 mm ±0,50 mm
Weight in air
240 kg/km nom.
Weight in seawater
75 kg/km nom.
Min. bending radius, static
90 mm
Min. bending radius, dynamic
150 mm
Operating voltage
600 V
Test voltage
4000 V DC for 1 min. (cond./cond.)
3000 V DC for 1 min. (cond./shield)
500 V DC for 1 min. (shield/shield)
Conductor resistance
20,0 ohm/ km
Insulation resistance
10000 Mohm* km (cond./shield)
100 Mohm* 100 m (shield/shield)
Capacitance
100 pF/ m
17
No. 2002625C - Rev. F - 02/12
 
 

 


 



 








 





 






  






 
Instrumentation cables
7 STP Data cable - Type 4700
Shielded twisted pairs
0,50 mm2 bare copper conductor insulated with PE. Two conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (7 ea.)
Shield
Aluminium/polyester foil and tinned copper drain wire, coverage 100%
Outer jacket
Polyurethane jacket. Colour blue
Diameter
12,70 mm ±0,30 mm
Weight in air
205 kg/ km nom.
Weight in seawater
115 kg/ km nom.
Min. bending radius, static
120 mm
Min. bending radius, dynamic
150 mm
Depth rating
3000 m
Operating voltage
600 V
Test voltage
3000 V DC for 1 min.
Conductor resistance
41,0 ohm/ km
Insulation resistance
500 Mohm* km (cond./cond.)
100 Mohm* km (cond./shield)
10 Mohm* km (shield/shield)
Capacitance
100 pF/ m
Impedance
57 ± 5 Ohm at 1-10 MHz
Attenuation
7.0 dB/ 100 m at 1 MHz
18.0 dB/ 100 m at 10 MHz
20
No. 2005746C - Rev. B - 02/12
Instrumentation cables
Instrumentation Cable - Type 6589
2
Conductors
1,00 mm bare copper conductor insulated with PE (4 ea.)
Inner jacket
PVC jacket
Shield
Bronze braiding
Outer jacket
Polyurethane jacket. Colour black
Diameter
9,80 mm ±0,30 mm
Weight in air
140 kg/ km nom.
Weight in seawater
62 kg/ km nom.
Min. bending radius, static
130 mm
Min. bending radius, dynamic
150 mm
Breaking strength
1 kN (braiding only)
Depth rating
6000 m
Operating voltage
600 V
Test voltage
3000 V DC for 1 min.
Conductor resistance
20,0 ohm/ km
Insulation resistance
5000 Mohm* km
Capacitance
70 pF/ m
Impedance
100 ohm at 100 kHz
No. 2005752C - Rev. B - 02/12
21
Instrumentation cables
7 Conductor shielded cable 0,50mm2 - Type 5071
Strength member
Aramid yarn insulated with PE (1 ea)
Conductors
0,50 mm2 bare copper conductor insulated with PE (7 ea.)
Shield
Tinned copper braid, coverage 85%
Outer jacket
Polyurethane jacket. Colour black
Diameter
10,00 mm ±0,30 mm
Weight in air
140 kg/ km nom.
Weight in seawater
60 kg/ km nom.
Breaking strength
> 3600 N
Min. bending radius, static
70 mm
Min. bending radius, dynamic
100 mm
Depth rating
3000 m
Operating voltage
750 V DC
Test voltage
3000 V DC for 1 min.
Conductor resistance
41,0 ohm/ km
Insulation resistance
10000 Mohm* km (cond./cond.)
100 Mohm* 100 m (cond./shield)
10 Mohm/ km (shield/shield)
22
No. 2005760C - Rev. B - 02/12
Instrumentation cables
7 Conductor shielded cable - Type 5072
Conductors
1,50 mm2 bare copper conductor insulated with TPE. (7 ea.)
Shield
Tinned copper braid, coverage 85%
Outer jacket
Polyurethane jacket. Colour black
Diameter
9,50 mm ±0,30 mm
Weight in air
172 kg/km nom.
Weight in seawater
100 kg/km nom.
Min. bending radius, static
95 mm
Min. bending radius, dynamic
115 mm
Depth rating
3000 m
Operating voltage
480 V DC
Test voltage
3000 V DC for 1 min.
Conductor resistance
14,0 ohm/ km
Insulation resistance
100 Mohm* km
No. 2005748C - Rev. B - 02/12
23
Instrumentation cables
12 Conductor shielded cable 0,50mm2 - Type 5121
2
Conductors
0,50 mm tinned copper conductor insulated with PVC. (12 ea.)
Shield
Aluminium/ polyester foil, coverage 100%
Tinned copper braid, coverage 90%
Outer jacket
Polyurethane jacket. Colour black
Diameter
12,00 mm ±0,30 mm
Weight in air
225 kg/ km nom.
Weight in seawater
110 kg/ km nom.
Min. bending radius, static
145 mm
Min. bending radius, dynamic
180 mm
Depth rating
3000 m
Operating voltage
300/ 500 V U/ Uo
Test voltage
2000 V DC for 1 min
Conductor resistance
41,0 ohm/ km
Insulation resistance
100 Mohm* km
24
No. 2005750C - Rev. B - 02/12
Instrumentation cables
12 Conductor shielded cable 1,50mm2 - Type 5122
2
Conductors
1,50 mm bare copper conductor insulated with TPE. (12 ea.)
Shield
Tinned copper braid, coverage 85%
Outer jacket
Polyurethane jacket. Colour black
Diameter
12,10 mm ±0,30 mm
Weight in air
280 kg/ km nom.
Weight in seawater
165 kg/ km nom.
Min. bending radius, static
125 mm
Min. bending radius, dynamic
145 mm
Depth rating
3000 m
Operating voltage
480 V
Test voltage
3000 V DC for 1 min.
Conductor resistance
14,0 ohm/ km
Insulation resistance
100 Mohm* km
25
No. 2005750C - Rev. B - 02/12
Fibre optic cables
Hybrid SM/ MM cable - Type 3784
Fibre optic element
Steel tube (2,3mm OD) with eight single mode corning SMF 28e (9/125).
Four multi mode Corning InfiniCor 600 or equivalent (50/125), filling compound LA444
(minimum 90% fill) With a polyethylene jacket - black
- SM Colours: White, yellow, green, blue, red, orange, brown, grey
- MM Colours: Black, pink, violet, aqua
Conductors
1,0 mm (18 awg) tin plated copper conductor with dual wall insulation system. Primary
jacket XL polyvinylidene fluoride. O.D. 2,23mm. (7 ea.)
Wrap
Mylar tape
Outer jacket
Ray thane C 1,3 mm wall thickness
Outer jacket
Red
Diameter
10,5 mm ±0,50 mm
Operating temperature
-20°C to 80°C
Weight in air
171 kg/ km nom.
Weight in seawater
82 kg/ km nom.
Min. bending radius
100 mm static
150 mm dynamic
Depth rating
6000 metres
2
Electrical and Fibre Optical Characteristics
Operating voltage
2500 V (RMS)
DC Resistance @20C
20,4 ohm/km
Fibre Attenuation
SM –dB/
km
MM –dB/
km
0,6 max @ 1310nm
0,4 max @ 1550nm
2,9 max @ 850nm
0,6 max @ 1300nm
26
No. 2005742C - Rev. D - 02/12
Fibre optic cables
Optical cable - Type 4 SM
¨
Optical fibres
Single mode fibre with Hytrel buffer.
Plow steel 8 x 0,38 mm strength member and HDPE jacket (4 ea.)
Jacket
PUR jacket. Colour red
Diameter
9,0 mm
Min. bending diameter
110 mm static
150 mm dynamic
Depth rating
6000 metres
Attenuation
0,45 dB/ km at 1310 nm
0,30 dB/ km at 1550 nm
27
No. 2001589C - Rev. C - 02/12
Fibre optic cables
Electrical/Optical cable - Type 4MM 50/125 + 3 EL
Optical fibres
50/
125/
245µm mul
t
i
modef
i
br
ewi
t
hHy
t
r
el
buf
f
er–0,
18mm wal
l
.
Pl
owst
eel
8x0,
38mm st
r
engt
hmemberandNy
l
onj
ack
et–0,
33mm wal
l
(
4ea.
)
Conductors
1,0 mm2 copper conductors insulated with PE (3 ea.)
Jacket
PUR jacket. Colour blue
Diameter
9,6 mm
Min. bending diameter
120 mm static
160 mm dynamic
Voltage rating
600/1000 V
Attenuation
3,8 dB/ km at 850 nm
1,8 dB/ km at 1300 nm
Bandwidth
400 MHz* km at 850 nm
600 MHz* km at 1300 nm
No. 2001590C - Rev. C - 02/12
28
Fibre optic cables
4 Fiber single mode 9/125 cable - Type 3409/B
Centre fill
Aramidic yarn
Optical fibres
Single mode 9/125/245 µm optical fibres in unitube, 1,7 mm diameter. (4 ea.)
Fibre colours: Red, white, green, white.
Inner jacket
Polyurethane jacket.
Strength member
Kevlar braiding
Outer jacket
Polyurethane jacket. Colour red
Diameter
9,10 mm ±0,20 mm
Weight in air
90 kg/ km nom.
Weight in seawater
23 kg/ km nom.
Min. breaking strength
2,5 kN
Min. bending radius, static
110 mm
Min. bending radius, dynamic
145 mm
Max. pressure resistance
300 bar
Depth rating
5000 m
Optical, trans massive and dimensional
characteristics
In accordance with ITU-T G652
Max. attenuation
0,40 dB/ km at 1300 nm
0,25 dB/ km at 1550 nm
29
No. 2005740C - Rev. C - 02/12
Fibre optic cables
Electrical/Optical cable - Type 3444
Fibre optic element
Loose tube with 4 multimode optical fibres 50/125 µm with Kevlar reinforcement
and polyolefin sheath. 3 mm diameter. Fibre colours: Grey, white, red, black.
Conductors
1,0 mm stranded tinned copper conductor insulated with polyofin.
3 mm diameter. Conductor colours: Blue, black, red, brown. (4 ea.)
Filler
Filler element
Fibre optic element
Loose tube with 4 single mode optical fibres 9/125 µm with Kevlar reinforcement
and polyolefin sheath. 3 mm diameter. Fibre colours: Blue, orange, green, brown.
Inner jacket
Polyurethane jacket. Colour: Red
Strength member
Kevlar braiding
Outer jacket
Polyurethane jacket. Colour red
Diameter
15,50 mm ±0,40 mm
Operating temperature
-20°C to 80°C
Weight in air
235 kg/ km nom.
Weight in seawater
42 kg/ km nom.
Min. breaking strength (Strength member)
15 kN
Min. bending radius
230 mm
Depth rating
5000 metres
2
Electrical and Fibre Optical Characteristics
Operating voltage
1000 Vdc
Max. attenuation
3,00 dB at 850 nm for multi mode fibres
0,80 dB at 1300 nm for multi mode fibres
0,40 dB/ km at 1300 nm for single mode fibres
0,25 dB/ km at 1550 nm for single mode fibres
30
No. 2006816C - Rev. B - 02/12
Special cables
Multipurpose coax cable - Type 0799
2
Coax
1,94 mm stranded bare copper wires insulated with PE- 1,40 mm wall.
0,08 mm2 bare copper wire shield and copper polyester tape. 1 ea.
Jacket PE j
ac
ket
– 0,
98 mm wal
l
Armour
Inner layer: 24 x 0,95 mm wire GIPS
Outer layer: 24 x 1,22 mm wire GIPS
Diameter
11,43 mm
Weight in air
469 kg/ km
Weight in seawater
379 kg/ km
Breaking strength
71,2 kN
Max. working load
17,8 kN
Min. bending radius
230 mm
Voltage rating
1900 V DC
Insulation resistance
3000 Mohm* km
DC resistance
9,8 ohm/km for coax conductor
6,9 ohm/km for coax shield
Impedance
40 ohm
Capacitance
131 pF/m
Attenuation
10,5 dB/km at 1 MHz
23,3 dB/km at 5 MHz
31
No. 2005755C - Rev. A - 02/12
Special cables
Focus/ Triaxus cable - Type 0382
Conductors
0,24 mm2 (24 AWG) copper conductor insulated with PP (2 ea.)
Electro/Optical element
8,3/125/245 µm single mode optical fiber with Hytrel buffer, 0,92 mm² (18 AWG) HD
copper serve and PP belt (2 ea.)
Inner Jacket
PE Jacket
Armour
One l
ay
er
of
gal
v
ani
z
ed s
t
eel
wi
r
es
– 14 x
1,
32 mm One l
ay
er
of
gal
v
ani
z
ed s
t
eel
wi
r
es
– 24 x
1,
07 mm Diameter
9,98 mm
Weight in air
389 kg/ km
Weight in seawater
322 kg/ km
Specific gravity
5.8
Min. breaking strength
71 kN
Working load
15 kN
Recommended bending radius
200 mm
Electrical and Fibre Optical Characteristics
Operating voltage
500 V for conductor
1200 V for electro/optical element
DC resistance
82,0 ohm/ km for conductor
21,3 ohm/ km for electro/optical element
Insulation resistance
3000 Mohm* km for conductor and electro/optical element
Attenuation
0,45 dB/ km at 1310 nm
0,35 dB/ km at 1550 nm
32
No. 2002641C - Rev. D - 02/12
Non stock cables
Sonar & Acoustic System Cables
Historically side scan sonar systems were towed by multi-core steel or aramide
armoured cables. Although these cable types are still an industry standard,
there has been an upsurge in acoustic, digital and telemetry technology which
demand a new approach to cable engineering. We supply the complete range
of cables for acoustic applications including armoured coaxial cables for side
the most advanced acoustic systems.
Video System Umbilicals
The advances in underwater vision systems have developed dramatically
over the years. This has led to new designs in cables using sophisticated
transmission systems with multiple broad band channels. We supply traditional
diver, sewer inspection and well head TV system cables, however, we are
transmission systems for security systems, ROV & ROTV systems, underwater
trenchers and ploughs.
ROV and Trencher Umbilicals
As ROV systems get larger, more powerful and operate in deeper waters, the
demand on the cable system becomes a critical issue. Fibre optic, high voltage
umbilicals are now common place and we supply standard and special designs
to this market. These include steel armoured lift umbilicals and aramide
reinforced tether cables. Also part of our program are neutrally buoyant tethers
for Tether Management Systems and smaller ROV systems. We have also
designed and built special cables for long excursion (tunnel inspection).
Dynamic Cable Ancilliary Products
Traditionally dynamic cables and terminations have been considered to be
t
he “
weak
l
i
nk
”
i
n t
he r
el
i
abi
l
i
t
y
of
under
wat
er
sys
t
ems.
MacAr
t
ney
has al
ways viewed a dynamic cable as a system which includes connectors, mechanical
terminations, protection, buoyancy, sheaves, handling systems etc. To
support our in-house engineered designs, we also supply a complete range
of winch systems, slip rings, cable moulding, underwater electrical and optical
connectors, mechanical terminations, penetrators, cable buoyancy, sheaves
and cable status indicators fully supported by our in-house
33
Terminations
Standard Steel Termination
Our standard shackle or fork terminations are safe and reliable
methods of connecting cable to towed underwater vehicles or for lifting
a heavy object, such as a down-hole camera system. Terminating and
moulding the cable to a connector ensures a watertight connection
from cable to system. MacArtney stocks standard terminations for
steel armoured or Kevlar armoured cables with diameters of 6 to
14mm and loads of up to 1500kg. We also have extensive experience
of designing terminations for loads of up to 100 tonnes.
Bend Restrictors & Bend Stiffeners
Bend restrictors and stiffeners are designed to minimse sharp
cable bends, protecting them from stress damage and kinks. They
mechanically limit the bend and prevent unwanted tension.
Chamber Terminations
MacArtney chamber terminations connect a cable to a specially
designed connector. The chamber transfers the entire force from
the cable to the steel parts of the termination, maintaining the safe
working load of the cable throughout the connection. The chambers
makes it possible to replace the connector or cable relatively easily
re-using the metal termination parts.
Oil Compensation
either with an internal bladder or an external reservoir. They can be
PE Mouldings
PE moulding is a secure and economical method of connecting
PE jacketed cables and connectors without the need for an oil
compensated system. A special hot moulding machine forces PE
moulding material into the moulding form under high pressure,
34
Extension & Take Out of Fibre Optic
Ex
t
ensi
on and “
t
ake out
”
t
er
mi
nat
i
ons
ar
e used when cabl
es hav
e been damaged or if they need to be extended to reach new locations.
main cable. The terminations are usually designed to have the same
working load and depth rating as the cable, and are often designed
with a lifespan of 10 to 15 years in seawater.
Penetrators
MacArtney makes a broad range of standard and customer-designed
penet
r
at
or
s
f
or
use at
al
l
wat
er
dept
hs – ev
en f
ul
l
ocean dept
h.
Penetrators are designed to connect systems to infrastructure, and
optic transmissions. They are available with or without internal water
cables, or combinations of both. MacArtney penetrators are available
with a range of housing types or with custom made housing. They are
delivered with 1 metre pigtails and ST connectors as standard.
Optolink Fibre penetrator
withstand the challenges of system infrastructure at pressures of up to
600 bars. It is completely blocked on both sides, so even if the cable
is damaged, water will not enter. It is available with 3 types of housing;
custom made housing. They are interchangeable and can be replaced
delivered with 1 metre pigtails and ST connectors as standard.
FITA Field Installable Termination Assembly
system that assembles a harness cable or array of harness cables
to a cable, typically from subsea control systems to an umbilical.
The FITA can be assembled on site without the need for mouldings.
termination entirely watertight at every level. FITA terminations are oil
compensated, maintaining the same pressure inside the termination
as outside. This allows them to operate at 600 bars without the need
4-6 months.
35































































































































Download