Location: FLOOR MOUNTED SERVICE SINK CARRIER WITHOUT FITTING MC-61 Specification: MIFAB Series MC-61 floor mounted service sink carrier with two lacquered 2" x 1" x 1/8" thick structural steel uprights with 3" x 4 ½" welded steel feet, and back outlet waste connection (specify no hub or threaded waste connection). Complete with lacquered cast iron faceplate assembly, lacquered cast iron nipple and waste connector, adjustable 8" tapered thread ABS nipple with integral test cap, neoprene bowl gasket, hardware, threaded rod protectors and polished chrome plated finishing cap nuts. Function: Used with off the floor wall urinals and service sinks that are wall mounted, and have no contact with the finished floor. Typically installed in utility, emergency and clean-up rooms where the narrow wall design does not accommodate the carrier fitting. The closet carrier is completely concealed within the wall and supports the load of the fixture through a faceplate and foot support system that is anchored to the floor. Sanitation underneath the fixture is more efficiently and economically maintained when installed off of the floor compared to floor mounted. Note: 8” tapered thread ABS nipple shipped standard with MC-10 Series “X” = 4 5/8” MIN, carriers. The universal faceplate 5 3/4” MAX, assembly accepts all nipple variations, WITH STANDARD rolling thread (-OR), cast iron (-CI) and NIPPLE. 1 1/4” IS 22" UNIVERSAL tapered thread ABS with adjustable POSSIBLE "X" PLATE horn (-AH). WITH SHORTENED ASSEMBLY SECURED TO UPRIGHTS "U" BOLTS TO SECURE UNIVERSAL PLATES TO UPRIGHT NIPPLE. FOR GREATER THAN STANDARD MAX, USE LONGER NIPPLES AND SPECIFY DIMENSION REQUIRED. 36" LACQUERED CAST IRON NIPPLE AND WASTE CONNECTOR ILLUSTRATED WITH 4” F.I.P. WASTE CONNECTION. SPECIFY -N FOR 4” NO HUB WASTE CONNECTION AND USE THE MI-850-4 EXTRA HEAVY DUTY RECTANGULAR STEEL STRUCTURAL UPRIGHTS 7" "X" FACEPLATE MOUNTING BRACKETS 3" MC-61 Series Meets ANSI/ASME fixture carrier standard A112.6.1M-97 300lb. load rating ABS TAPERED THREADED NIPPLE WITH INTEGRAL TEST CAP 4 1/2" HEAVY DUTY WELDED FEET THAT FIT WITHIN STANDARD STUD WALL CONSTRUCTION FINISHED WALL MODEL NUMBER CHART MC-61-T - 4" F.I.P. waste connection MC-61-N - 4" No Hub waste connection Note: Blow-out configuration illustrated; for siphon jet, invert face plate. Note: See the various fixture dimensional rough-in guides on the www.mifab.com website. SUFFIX OPTIONAL VARIATIONS -AH8 -AH12 -BA -CI-4 -CI-6 -CI-8 -CI-12 -CI-24 -HD -HD-750 -HDX N Job Name: Section No: Schedule No: 8" ABS nipple with adjustable horn 12" ABS nipple with adjustable horn Buy American Act compliant product 4" rolling thread cast iron nipple 6" rolling thread cast iron nipple 8" rolling thread cast iron nipple 12" rolling thread cast iron nipple 24" rolling thread cast iron nipple Heavy duty 500 lb. load rated carrier Heavy duty 750 lb. load rated carrier Extra heavy duty 1,000 lb. load rated carrier 4" no hub waste connection (with MI-850-4) SUFFIX OPTIONAL VARIATIONS -PA -PFAB T -1 -10 Pennsylvania Steel Act compliant product Prefabricated carrier 4" F.I.P. threaded waste connection Finishing / Tiling frame Auxiliary support, recommended with nipple lengths over 12" 12" tapered thread ABS nipple Galvanized cast iron Vandal proof finish trim Test plug for custom and cast iron nipples Nipple wrench Flush valve support Foot pedal valve mounting table -12 -13 -14 -17 -19 -20 -32 Page No: Contract: Purchase Order No: MIFAB reserves the right to make changes in material and design without formal notice or obligation. Page CR53 USA: 1-800-465-2736 www.mifab.com CAN: 1-800-387-3880 2013-06-26