Cut Sheet

advertisement
C2
312
| alure 2
integrations
w w w.al i ghts .c om
a·light
C2
| alure 2
project
type
quantity
Optics
under stack
blade baffle
stack
Additional Integrations Selections
Lengths:
nominal individual lengths up to 12'
nominal rows longer than 12'
ceiling
exact lengths to the nearest 100th of an inch
Optons:
custom finish
endcap feed
Design-Assist:
library
in-house design-assist team manages your unique project
Mounting:
under-stack mounting bracket
+
custom mounting
precise lengths
Cross Sections
Multiple configurations available - sampling shown
surface mount
T5
LED
2”
baffle
3-3/4”
baffle
Available Light Platforms
LED
integrations
T5
Available Mounting
ceiling
mount
controls
friendly
w w w.al i ghts .c om
under stack
mount
313
C2
| alure 2
integrations
Linear Dimensions:
C2 is only available as "integrations" due to the custom nature of stack
mounting. All lengths should be specified as follows...
Nominal Row
R___: Specify in nominal feet.
Choose when nominal length is acceptable.
Actual length will be shorter or longer due to metric lamp lengths. Lengths
over 12' are comprised of multiple sections.
Examples: a nominal 54ft row begins as C2R54; a 7ft individual as C2R7.
Exact Row
M___: Specify overall length in inches to the nearest hundredth.
Choose when exact lengths are required as determined by space
constraints, etc.
Submittals required. Lengths over 12' are comprised of multiple sections.
Examples: an exact 54ft row begins as C2M648.00; a 7ft individual as
C2M84.00.
Lamping:
LED. 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See
wattage/lumen table for specifications per foot. All
specifications are subject to change.
LED
T5/T5HO. Single lamp in cross section. Low-profile electronic, high
power factor, program start, sound rating A, inherent thermal
protection, UL listed Class P, <10% THD. Dimming: specify
T5
manufacturer/model.
Mounting:
Surface/Ceiling Mount. Fixture mounts directly to ceiling via
preattached mounting plate. Power connects inside fixture
using BX or MX style wiring. To install, detach mounting plate
via thumbscrews inside fixture. Affix plate to ceiling via
pre-drilled holes or by drilling through plate. Power knockout is
located in center of mounting plate. Reattach fixture to
mounting plate via thumbscrews.
.
Stack Top Mount. Steel prepainted mounting plate (provided) bolts to
stack top by drilling through plate anywhere attachment is
needed. Fixture then bolts to mounting plate. Factory assumes
J-Box is in the floor at the beginning of each row of stacks/
frames or “range”. Power runs up through the unistrut channel
located in the center of the range and into the inside of the
upper shelf. Connect power inside the stack within the first shelf in the
back. Power location must be specified via the submittal process. Factory
requires stack drawings.
NOTE: When stack top mounting, take into consideration clearance for
books. Allow for an additional 3” top height to accommodate books.
Finish:
Electrostatically applied powder coat finish.
Construction:
60% recycled aluminum extruded housing. Precision milled endcaps.
Listing:
UL/CUL. Damp Location.
Companion Luminaires:
A1 suspended/ceiling, A4 wall, C3 table mount, C4 stack
Legend:
1.
Emergency ballast not applicable on lengths 3ft or less.
2.
Multi-circuiting: submit multi-circuiting requirements during submittal process.
3.
Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter.
4.
Standard occupancy sensor with photocell: Wattstopper FS-205 wired for daylight
harvesting. Requires 0-10V dimming ballast.
314
w w w.al i ghts .c om
a·light
C2
| alure 2
project
type
quantity
interior
Series:
C2
Dimension:
C2 is only available as "integrations" due to the modifications
required for stack mounting
R___
M___
Lamping:
LED standard output
LS
LED high output
LH
T5 (1)
S
T5HO (1)
H
LED Temp (if applicable):
3000k
30
3500k
35
4000k
40
Voltage:
universal 120V - 277V
U
120V
1
277V
2
347V
3
Downlight Optics:
white blade baffle
B
custom
C
Upper Optics:
100% downlight (direct only)
H
Mounting:
stack top mount
ST
surface/ceiling mount
F
custom
C
Finish:
a∙lightanium™
T
satin white
W
satin black
B
textured eggshell white
E
other - specify RAL#
O
custom
C
Options:
dimming - specify manufacturer, model/series and voltage
D
emergency (fluorescent only) - specify model/series or lumens 1 E
external fusing
F
multi-circuit 2 M
new york city code
N
occupancy sensor 3 O
photocell/daylight sensor 4 P
right endcap feed
R
left endcap feed
L
LED
per foot
LS
LH
wall
damp location nominal length (specify length in feet)
exact length (specify length in inches to the nearest 100th)
1 board in cross
watts/ft
lumens/ft
5
600
10
1200
Lumens at board at 4000k.
Consult IES files online for delivered lumens.
Specifications subject to change.
integrations
w w w.al i ghts .c om
Version | March 2014
315
Download