C2 312 | alure 2 integrations w w w.al i ghts .c om a·light C2 | alure 2 project type quantity Optics under stack blade baffle stack Additional Integrations Selections Lengths: nominal individual lengths up to 12' nominal rows longer than 12' ceiling exact lengths to the nearest 100th of an inch Optons: custom finish endcap feed Design-Assist: library in-house design-assist team manages your unique project Mounting: under-stack mounting bracket + custom mounting precise lengths Cross Sections Multiple configurations available - sampling shown surface mount T5 LED 2” baffle 3-3/4” baffle Available Light Platforms LED integrations T5 Available Mounting ceiling mount controls friendly w w w.al i ghts .c om under stack mount 313 C2 | alure 2 integrations Linear Dimensions: C2 is only available as "integrations" due to the custom nature of stack mounting. All lengths should be specified as follows... Nominal Row R___: Specify in nominal feet. Choose when nominal length is acceptable. Actual length will be shorter or longer due to metric lamp lengths. Lengths over 12' are comprised of multiple sections. Examples: a nominal 54ft row begins as C2R54; a 7ft individual as C2R7. Exact Row M___: Specify overall length in inches to the nearest hundredth. Choose when exact lengths are required as determined by space constraints, etc. Submittals required. Lengths over 12' are comprised of multiple sections. Examples: an exact 54ft row begins as C2M648.00; a 7ft individual as C2M84.00. Lamping: LED. 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See wattage/lumen table for specifications per foot. All specifications are subject to change. LED T5/T5HO. Single lamp in cross section. Low-profile electronic, high power factor, program start, sound rating A, inherent thermal protection, UL listed Class P, <10% THD. Dimming: specify T5 manufacturer/model. Mounting: Surface/Ceiling Mount. Fixture mounts directly to ceiling via preattached mounting plate. Power connects inside fixture using BX or MX style wiring. To install, detach mounting plate via thumbscrews inside fixture. Affix plate to ceiling via pre-drilled holes or by drilling through plate. Power knockout is located in center of mounting plate. Reattach fixture to mounting plate via thumbscrews. . Stack Top Mount. Steel prepainted mounting plate (provided) bolts to stack top by drilling through plate anywhere attachment is needed. Fixture then bolts to mounting plate. Factory assumes J-Box is in the floor at the beginning of each row of stacks/ frames or “range”. Power runs up through the unistrut channel located in the center of the range and into the inside of the upper shelf. Connect power inside the stack within the first shelf in the back. Power location must be specified via the submittal process. Factory requires stack drawings. NOTE: When stack top mounting, take into consideration clearance for books. Allow for an additional 3” top height to accommodate books. Finish: Electrostatically applied powder coat finish. Construction: 60% recycled aluminum extruded housing. Precision milled endcaps. Listing: UL/CUL. Damp Location. Companion Luminaires: A1 suspended/ceiling, A4 wall, C3 table mount, C4 stack Legend: 1. Emergency ballast not applicable on lengths 3ft or less. 2. Multi-circuiting: submit multi-circuiting requirements during submittal process. 3. Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter. 4. Standard occupancy sensor with photocell: Wattstopper FS-205 wired for daylight harvesting. Requires 0-10V dimming ballast. 314 w w w.al i ghts .c om a·light C2 | alure 2 project type quantity interior Series: C2 Dimension: C2 is only available as "integrations" due to the modifications required for stack mounting R___ M___ Lamping: LED standard output LS LED high output LH T5 (1) S T5HO (1) H LED Temp (if applicable): 3000k 30 3500k 35 4000k 40 Voltage: universal 120V - 277V U 120V 1 277V 2 347V 3 Downlight Optics: white blade baffle B custom C Upper Optics: 100% downlight (direct only) H Mounting: stack top mount ST surface/ceiling mount F custom C Finish: a∙lightanium™ T satin white W satin black B textured eggshell white E other - specify RAL# O custom C Options: dimming - specify manufacturer, model/series and voltage D emergency (fluorescent only) - specify model/series or lumens 1 E external fusing F multi-circuit 2 M new york city code N occupancy sensor 3 O photocell/daylight sensor 4 P right endcap feed R left endcap feed L LED per foot LS LH wall damp location nominal length (specify length in feet) exact length (specify length in inches to the nearest 100th) 1 board in cross watts/ft lumens/ft 5 600 10 1200 Lumens at board at 4000k. Consult IES files online for delivered lumens. Specifications subject to change. integrations w w w.al i ghts .c om Version | March 2014 315