C2 | alure 2 project type quantity Optics under stack blade baffle T5 LED 2.25 2.25 2.06 baffle white acrilic diffuser aperture 1252 Lumen Guide Output Nominal wattage Efficacy 847 lm/ft 9.5 W/ft 89 lm/W 939 626 313 Available Light Platforms LED T5 1 controls friendly Available Mounting ceiling mount 1 under stack mount w w w.al i ghts .c om integrations C2 | alure 2 integrations Linear Dimensions: C2 is only available as "integrations" due to the custom nature of stack mounting. All lengths should be specified as follows... Nominal Row R___: Specify in nominal feet. Choose when nominal length is acceptable. Actual length will be shorter or longer due to metric lamp lengths. Lengths over 12' are comprised of multiple sections. Examples: a nominal 54ft row begins as C2R54; a 7ft individual as C2R7. Exact Row M___: Specify overall length in inches to the nearest hundredth. Choose when exact lengths are required as determined by space constraints, etc. Submittals required. Lengths over 12' are comprised of multiple sections. Examples: an exact 54ft row begins as C2M648.00; a 7ft individual as C2M84.00. Output / Lamping: LED. 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See wattage/lumen table for specifications per foot. All specifications are subject to change. T5/T5HO. Single lamp in cross section. Low-profile electronic, high power factor, program start, sound rating A, inherent thermal protection, UL listed Class P, <10% THD. Dimming: specify manufacturer/model. Mounting: Surface/Ceiling Mount. Fixture mounts directly to ceiling via preattached mounting plate. Power connects inside fixture using BX or MX style wiring. To install, detach mounting plate via thumbscrews inside fixture. Affix plate to ceiling via pre-drilled holes or by drilling through plate. Power knockout is located in center of mounting plate. Reattach fixture to mounting plate via thumbscrews. Stack Top Mount. Steel prepainted mounting plate (provided) bolts to stack top by drilling through plate anywhere attachment is needed. Fixture then bolts to mounting plate. Factory assumes J-Box is in the floor at the beginning of each row of stacks/frames or “range”. Power runs up through the unistrut channel located in the center of the range and into the inside of the upper shelf. Connect power inside the stack within the first shelf in the back. Power location must be specified via the submittal process. Factory requires stack drawings. Driver: Constant Current LED Systems: Inherent dimming Power Factor > 90% 90°C case rating Inherent short-circuit protection <20% total harmonic distortion Extreme low-temperature performance to -40°C Sound rating A UL/CSA Listed Class 2 rating IP66 rated Universal 120-277V Output: LS_ _: LED standard output 600 lm/ft 5 watts/ft LH_ _: LED high output 1200 lm/ft 10 watts/ft Color Temp: 85CRI is standard; 90+ is available upon request. Insert a 2-digit number for color temp after the LED nomenclature. 30 = 3000 K 35 = 3500 K 40 = 4000 K Consult factory for special order color temperatures. LED Optics: WISP™ lens is the factory standard recommendation for use with LED. Available options are dependent upon a particular luminaire. Consult factory prior to specification. T5/T5HO: Single or dual lamps in cross section. Program start is factory standard. Finish: Electrostatically applied powder coat finish. Construction: 60% recycled aluminum extruded housing. Precision milled endcaps. Listing: UL/CUL. Damp Location. Companion Luminaires: A1 suspended/ceiling, A4 wall, C3 table mount, C4 stack NOTE: When stack top mounting, take into consideration clearance for books. Allow for an additional 3” top height to accommodate books. LED: 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See wattage/lumen table for specifications per foot. All specifications are subject to change. Built with high-performance Nichia® LED’s. Heat sync designed to ensure proper performance. LED boards are replaceable, built in foot-long increments. Board position/quantity to be determined by factory. a·light w w w.al i ghts .c om 2 C2 | alure 2 LED project Series: type quantity C2 Dimension: C2 is only available as "integrations" due to the modifications required for stack mounting Damp location nominal length Exact length R___ M___ Output: LED standard output LED high output LS LH 3000k 3500k 4000k 30 35 40 Specify length in feet. Specify length in inches to the nearest 100th. LED Temp (if applicable): Voltage: Universal 120V - 277V 120V 277V 347V U 1 2 3 WISP™ lens S Downlight Optics: Mounting: Surface / Ceiling mount a∙lightanium™ Satin white Satin black Textured eggshell white Other Custom F Finish: T W B E O C Specify RAL# Options: 3 Dimming D Emergency E External fusing F Multi-circuit M New York City code N Occupancy sensor O Photocell / Daylight sensor P Right endcap feed Left endcap feed R L Specify manufacturer, model/series and voltage. Emergency ballast not applicable on lengths 3ft or less. Specify model/series or lumens. Multi-circuiting: submit multi-circuiting requirements during submittal process. Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter. Standard fixture-integrated dimmimg photosensor: Wattstopper FD-301 wired for daylight harvesting. Requires 0-10V dimming ballast. w w w.al i ghts .c om Version | November 2015 integrations C2 | alure 2 T5 T8 project Series: type quantity C2 Dimension: C2 is only available as "integrations" due to the modifications required for stack mounting Damp location nominal length R___ Specify length in feet. Exact length M___ Specify length in inches to the nearest 100th. Lamping: T5 (1) T5HO (1) S H Universal 120V - 277V 120V 277V 347V U 1 2 3 WISP™ lens S Voltage: Downlight Optics: Mounting: Surface / Ceiling mount a∙lightanium™ Satin white Satin black Textured eggshell white Other Custom F Finish: T W B E O C Specify RAL# Options: a·light Dimming D Specify manufacturer, model/series and voltage. Emergency E External fusing F Emergency ballast not applicable on lengths 3ft or less. Specify model/series or lumens. Multi-circuit M New York City code N Occupancy sensor O Photocell / Daylight sensor P Right endcap feed Left endcap feed R L Multi-circuiting: submit multi-circuiting requirements during submittal process. Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter. Standard fixture-integrated dimmimg photosensor: Wattstopper FD-301 wired for daylight harvesting. Requires 0-10V dimming ballast. w w w.al i ghts .c om 4