POLYSITE® 2000 series - Hybrid: titanium and POM*
MICRO
  Good flat stability
Non-traumatic angles
  Minimum weight
POM* radiopaque connecting rings
  Flat lateral edges for good adherence
Port characteristics
References
Port type/
Material
With
introducer
Without
introducer
PEDIATRIC
2005
2005 ISP
2015 ISP
2105 ISP
2115
ADULT
2116
2116 ISP
ADULT
2007
2007 ISP
2107
2107 ISP
No preconnected
•
Pediatric
micro-port
titanium/POM*
•
•
•
•
•
Septum
diameter
(mm)
Weight
(g)
Diameter
of pull out rod
(mm)
Internal
volume (ml)
22 x 17
8,7
8
2,9
0,7
0,2
22 x 17
8,7
8
2,9
0,9
0,2
22 x 17
8,7
8
2,9
1
0,2
•
•
•
•
•
•
•
•
Adult
micro-port
titanium/POM*
Port height
(mm)
•
•
Adult
micro-port
titanium/POM*
Base
diameter
(mm)
•
•
•
2115 ISP
2016 ISP
Preconnectéd
•
•
•
•
•
•
•
Silicone catheters characteristics
PEDIATRIC
References
Catheter
Internal
diameter (mm)
External
diameter (mm)
Length
(mm)
Internal volume
(ml/10 cm)
Sheath
introducer
Débits** (ml/min)
Silicone
0,65
1,65
600
0,04
5F
8,5 (22G)
10 (20G)
10,5 (19G)
7F
13 (22G)
20 (20G)
26 (19G)
2005
2005 ISP
2105 ISP
ADULT
2007
2007 ISP
2107
Silicone
1,02
2,16
800
0,09
2107 ISP
Peel-away sheath
2 1 0 5 ISP ISP:
introducer
Polyurethane catheters characteristics
PEDIATRIC
References
Catheter
Internal
diameter (mm)
External
diameter (mm)
Length
(mm)
Internal volume
(ml/10 cm)
Sheath
introducer
Débits** (ml/min)
Polyurethane
0,8
1,5
600
0,06
5F
11 (22G)
17 (20G)
17 (19G)
Polyurethane
1,2
1,9
800
0,13
6F
13 (22G)
25 (20G)
31 (19G)
2015
2015 ISP
2115 ISP
ADULT
2016
2016 ISP
2116
2116 ISP
COMPLETE SET CONTENT
• 1 standard port in titanium and POM* with a silicone septum
• 1 silicone or polyurethane radiopaque catheter
(graduated every cm with a mark every 5 cm from 5 to 40 cm)
• 2 connecting rings (only one for the pre-connected references)
• 1 straight Huber needle (23G)
• 1 catheter introducer
• 1 catheter rinse (only one for non pre-connected references)
• 1 x 5F, 6F or 7F introducer (with or without peal-away sheath)
• 1 J guidewire (0,018” or 0,035” / 40 or 60cm)
• 1 puncture needle 18G or 20G, 38 or 70 mm of usable length
• 1 x Ø 2 or Ø 2,5 mm tunneling device, 18 or 23 cm length
• 1 x 10ml syringe
*POM: Polyoxymethylene. **Average flow rate in ml/mn, under a 1 m column of water