Û INDEX Ü PADMOUNTED PRIMARY METERING GEAR (DEADFRONT) Models SPMD and SPMG, 5-35 kV. 200 and 600 Ampere. Single and Three Phase, Fused/Nonfused. Application: Shallbetter Inc. models SPMD and SPMG Padmounted Primary Metering Gear is constructed in accordance with the latest applicable industry standards and the local and/or National Electrical Code requirements. The Shallbetter SPMD and SPMG Padmounted Primary Metering Gear is intended for use where the service is fed underground and the revenue metering is measured at the primary voltage rate. For complete specifications, please contact your authorized Shallbetter factory representative. © 2002 Shallbetter Inc. www.shallbetter.com 3.1.1 Û INDEX Ü Û INDEX Ü PADMOUNTED PRIMARY METERING GEAR (DEADFRONT) Models SPMD and SPMG, 5-35 kV. 200 and 600 Ampere. Single and Three Phase, Fused/Nonfused. Catalog Number Selection Sheet. To be used in conjunction with Factory Check Sheet. 3.1.2 © 2002 Shallbetter Inc. www.shallbetter.com Û INDEX Ü Û INDEX Ü PADMOUNTED PRIMARY METERING GEAR (DEADFRONT) Models SPMD and SPMG, 5-35 kV. 200 and 600 Ampere. Single and Three Phase, Fused/Nonfused. Factory Check Sheet. To be used in conjunction with Catalog Number Selection Sheet. RATINGS: Nominal System Voltage/ Maximum Design Voltage Basic Insulation Level (BIL) Continuous Current (Line) Continuous (Load) o o o o o o o o ____/____ kV 15 kV, 95 kV BIL 25 kV, 125 kV BIL 35 kV, 150 kV BIL Other ___ kV, ___kV BIL 200 amp 600 amp 200 amp 600 amp ENCLOSURE: Material: o A60 Galvanneal Steel o 304L Stainless Steel o 5052-H32 Aluminum Paint Finish: o Green Munsell No., 7GY 3.29/1.5 o Gray (ANSI 70). Munsell No., 5BG 7.0/0.4 o Gray (ANSI 61). Munsell No., 8.3G 6.10/0.54 o Other: ____________________ 3-Point Latch Type: o Penta-Head Bolt and shielded padlockable shackle, Shallbetter #70155. manufactured to meet or exceed A.N.S.I. C57.12.28 for padmount Equipment Enclosure Integrity. o Max-Head Bolt and shielded padlockable shackle, Shallbetter #70156 o Padlocking Handle, Shallbetter #70153 Metering Compartment Barriers, (Model SPMD only): o 3/16”, Glass Reinforced Polyester, (standard) o 1/4, Clear Polycarbonate (Lexan), Replaces 3/16” Glass Reinforced Polyester Compartment Barriers. Instrument Transformers: o Current Transformers: Manufacturer: ____, Model: ____, Type: ____, kV: ____, Ratio: ____. o Potential Transformers: Manufacturer: ____, Model: ____Type: ____, kV: ____, Ratio: ____. o Meter Socket: Manufacturer: ____, Model: ____, Type: ____. o Louvers for enclosure ventilation. o Insulation “No-Drip” Compound. Applied to the inside surface of the enclosure roof to prevent condensation. o Base undercoating. Applied to the bottom 2” of the enclosure. o REA Deadfront Barriers. Barriers inside the enclosure door from each compartment, secured by recessed penta-head bolt. Note: Replaces compartment barriers, (Models SPMD only). o Rodent Plate. Seals base of enclosure, Metering Compartment side only, (Model SPMD only). o Ground Bails. (Located on the Deadfront, Model SPMD only). o Interface Bushing Well Inserts (200 amp only). o Specials: © 2002 Shallbetter Inc. www.shallbetter.com 3.1.3 Û INDEX Ü Û INDEX Ü PADMOUNTED PRIMARY METERING GEAR (DEADFRONT) Model SPMD, 5-35 kV. 200 and 600 Ampere. Single and Three Phase, Fused/Nonfused. H2 H1 l l l For 5 kV applications, use 15 kV table. Units available as enclosures only (customers supplied and installed component) or as complete units from the factory. For single phase units, special configurations and sizes, consult factory. 3.1.4 © 2002 Shallbetter Inc. www.shallbetter.com Û INDEX Ü Û INDEX Ü PADMOUNTED PRIMARY METERING GEAR (DEADFRONT) Model SPMG, 5-15 kV. 200 Ampere Max. Single and Three Phase, 15 kV Max. l l l l l For 5 kV applications, use 15 kV table. Utilizes General Electric JKM-95 and JVM-95 Instrument Transformers. Units available as enclosure only (customer supplied and installed components) or as complete units from the factory. For special configurations and sizes, consult factory. Not available above 15 kV. © 2002 Shallbetter Inc. www.shallbetter.com 3.1.5 Û INDEX Ü