Replacement of ATTAR Test Report No. 15/9095.3
The results of the tests, calibrations and/or measurements included in this document are traceable to
Australian/national standards.
Accredited for compliance with ISO/IEC 17025.
Accreditation Number: 2735
4 February 2016
Prepared for:
Attention:
Test Site:
Test Date:
Manufacturer:
Test Specimen, Size & Quantity:
Sampling & Direction of Testing:
Test Personnel:
Preparation:
Joint Width:
Air Temperature:
Test Standard:
Surface Structure :
Test Shoes:
Classification Criteria:
(TABLE 5 in AS 4586 - 2013)
Displacement Space:
Displacement Space Assessment
Group:
N/A
Job No: M16/9799
Godfrey Hirst
7 Factories Road
SOUTH GEELONG VIC 3220
Mandy Chandley
ATTAR, Unit 1, 64 Bridge Road, Keysborough.
9 July 2015
Unknown
GH LVP Orion and Vega, 25x152 cm, 5 off supplied.
Sampling conducted by client. Test direction parallel with grain profile. Refer to Figure 1.
Darryl Pierce & Douglas Lehne.
Washed with water and pH neutral detergent, rinsed with water, then dried.
N/A
22°C
AS 4586 - 2013 Slip resistance classification of new pedestrian surface materials – Appendix D.
Structured.
Lupos Picasso
Classification
No Classification
R9
R10
R11
R12
R13
Angle, degrees
<6
≥6<10
≥10<19
≥19<27
≥27<35
≥35
Not Measured
Corrected Mean Overall Acceptance
Angle
(rounded down to the nearest degree)
:
Classification:
10°
R10
These results apply only to the specimens tested and it is recommended that before selection of flooring or paving materials the effect of service conditions, including maintenance procedures and wear on their slip-resistance be checked.
NOTE: Any specimens supplied will be disposed of in one (1) months time, unless otherwise instructed.
Reviewed by:
ATTAR
Douglas Lehne
Slip Testing Technician
Approved Signatory
Marcus Braché
Senior Engineering Technician
Approved Signatory
This report may not be reproduced except in its entirety.
Replacement of ATTAR Test Report No. 15/9095.3
4 February 2016
GH LVP Orion and Vega.
Arrow indicates direction of test.
This report may not be reproduced except in its entirety.
Replacement of ATTAR Test Report No. 15/9095.2
The results of the tests, calibrations and/or measurements included in this document are traceable to
Australian/national standards.
Accredited for compliance with ISO/IEC 17025.
Accreditation Number: 2735
4 February 2016
Job No: M16/9799
Prepared for:
Attention:
Test Site:
Godfrey Hirst
7 Factories Road
SOUTH GEELONG VIC 3220
Mandy Chandley
ATTAR, Unit 1, 64 Bridge Road, Keysborough.
Test Date:
Test Specimens, Size &
Quantity:
29 June 2015
GH LVP Orion and Vega, 25x152 cm, 5 off supplied.
Sampling & Direction of Testing: Sampling conducted by client. Test direction parallel with grain profile. Refer to Figure 1.
Test Personnel:
Preparation:
Darryl Pierce
Washed with water and pH neutral detergent, rinsed with water, then dried.
Fixed/Unfixed:
Air Temperature:
Test Equipment:
Unfixed.
22°C
Test Standard:
Slider Rubber:
Munro Stanley Skid Resistance Tester (Pendulum)
Serial Number 0320, Calibrated 16/10/2013.
AS 4586: 2013 Slip resistance classification of new pedestrian surface materials – Appendix A.
Classification Criteria:
Slider 96 Batch No. #59 prepared on P400 & 3µm lapping film.
Refer to Classification Criteria, attached as Appendix 1.
British Pendulum Number
Classification:
1
41
Specimen Number
2 3 4
35 41 37
P3
5
37
SRV
38
*
These results apply only to the specimens tested and it is recommended that before selection of flooring or paving materials the effect of service conditions, including maintenance procedures and wear on their slip-resistance be checked.
* Slip Resistance Value.
NOTE: Any specimens supplied will be disposed of in one (1) months time, unless otherwise instructed.
Reviewed by: ATTAR
Douglas Lehne
Slip Testing Technician
Approved Signatory
Marcus Braché
Senior Engineering Technician
Approved Signatory
This report may not be reproduced except in its entirety.
Page 1 of 2
Replacement of ATTAR Test Report No. 15/9095.2
4 February 2016
GH LVP Orion and Vega.
Arrow indicates direction of test.
This report may not be reproduced except in its entirety.
Page 2 of 2
Replacement of ATTAR Test Report No. 15/9095.1
4 February 2016
The results of the tests, calibrations and/or measurements included in this document are traceable to
Australian/national standards.
Accredited for compliance with ISO/IEC 17025.
Accreditation Number: 2735
Job No: M16/9799
Prepared for:
Attention:
Test Site:
Test Date:
Godfrey Hirst
7 Factories Road
SOUTH GEELONG VIC 3220
Mandy Chandley
ATTAR, Unit 1, 64 Bridge Road, Keysborough.
29 June 2015
Test Specimens, Size and
Quantity:
Sampling and Direction of Test: Sampling conducted by client. Test direction parallel with grain profile. Refer to Figure 1.
Test Personnel:
Preparation:
GH LVP Orion and Vega, 25x152 cm, 5 off supplied.
Darryl Pierce
Washed with water and pH neutral detergent, rinsed with water, then dried.
Unfixed Fixed/Unfixed:
Air Temperature:
Test Equipment:
Test Standard:
Slider Rubber:
Classification Criteria:
22°C
Tortus Floor Friction Tester; Tortus Model Mk III (with integral printer), Serial No: 318.
AS 4586: 2013 Slip resistance classification of new pedestrian surface materials – Appendix B.
Slider 96 Batch No. 57
Refer to Classification Criteria, attached as Appendix 1.
Dynamic Coefficient of Friction
Classification:
Run 1
0.52
Run 2
0.53
D1
Mean
Rounded to 0.05
0.55
These results apply only to the specimens tested and it is recommended that before selection of flooring or paving materials the effect of service conditions, including maintenance procedures and wear on their slip-resistance be checked.
NOTE: Any specimens supplied will be disposed of in one (1) months time, unless otherwise instructed.
ATTAR
Douglas Lehne
Slip Testing Technician
Approved Signatory
Reviewed by:
Marcus Braché
Senior Engineering Technician
Approved Signatory
This report may not be reproduced except in its entirety.
Page 1 of 2
Replacement of ATTAR Test Report No. 15/9095.1
4 February 2016
GH LVP Orion and Vega.
Arrow indicates direction of test.
This report may not be reproduced except in its entirety.
Page 2 of 2