DDS28u SINGLE PHASE ELECTRONIC PLC METER 1. General DDS28u single-phase multi-function PLC watt-hour meter is designed as the terminal of Automatic Meter Reading (AMR) system. It can communicate and exchange the data with concentrator via power line. The meter can freeze the energy in the end of the month so the AMR system can read the data automatically in meter reading day. The performance of meter complies with the standard IEC61036 and IEC 62053-21 DDS28u is the multi- function and multi-tariff meter, it has four tariffs and can measure total active energy consumption in different tariff period. All data and parameters are stored in non- volatile memory. Remote control is one of the most important features of DDS28u. AMR system can cut off the power supply through switch off the relay inside the meter. The meter can also act as the repeater, i.e. AMR system can read the data in the DDS28u through maximum 3 levels to the destination, this function improve the reliability of AMR system a lot. 2. Specification Rated Voltage 120V, 220V, 230V, Reference frequency 50Hz or 60Hz Basic current 20(80) 10(60) (Maximum)A 3. Technical data Applicable Standard IEC 61036-2000 Service Lifetime 10 years Accuracy Class Active Class1 Working Temperature -25℃~+55℃ Max distance of infrared 4m communication Distance of PLC Communication 3km Starting current Class 1=0.004Ib Normal working voltage 0.8Un~1.1Un Power consumption =2W、2.5VA Over voltage protection Holley Metering Ltd. 6kV Page 1 Relative humidity =85% Dimension of profile 164.5×112×71mm Net Weight 0.9 kg 4. Functions 4.1) Energy display by LCD, maximum 6 integer and 2 decimal 4.2) Normal and reverse connection energy measurement 4.3) Four tariff and 10 time zone are definable 4.4) PLC data transmission based on CDMA technology on 125kHz Spread Spectrum Carrier. 4.5) Remote control 4.6) Programmable via HHU or PLC 4.7) Anti-tamper functions include reverse connection, short connection and so on. 4.8) Alarm for overload, reverse connection, clock battery low and so on 4.9) Maximal consumption can be limited 4.10) History data reservation in non-volatile memory. 4.11) Event records 4.12) Time synchronization and correction 4.13) Pulse output Notes: For the details of the functions, please see the TECHNICAL DESCRIPTION. 5. Outline drawing 71 164.5 112 Holley Metering Ltd. Page 2 6. Connection Diagram 7 1 L N 5 2 3 6 4 +脉 -冲 L' N' 7. Installation It requires to be mounted indoor on permanent wall, tighten the 3 screws and well connect the conducting plate in the terminal block. The connection should be according to the diagram curved in the terminal cover. 8. Guarantee 18 months in case that the meter is sealed and right operation. Holley Metering Ltd. Page 3