DDS28u SINGLE PHASE ELECTRONIC PLC METER

advertisement
DDS28u SINGLE PHASE ELECTRONIC PLC METER
1. General
DDS28u single-phase multi-function PLC watt-hour meter is designed as the terminal of
Automatic Meter Reading (AMR) system. It can communicate and exchange the data with
concentrator via power line. The meter can freeze the energy in the end of the month so the AMR
system can read the data automatically in meter reading day. The performance of meter complies
with the standard IEC61036 and IEC 62053-21
DDS28u is the multi- function and multi-tariff meter, it has four tariffs and can
measure total active energy consumption in different tariff period. All data and
parameters are stored in non- volatile memory.
Remote control is one of the most important features of DDS28u. AMR system
can cut off the power supply through switch off the relay inside the meter. The meter
can also act as the repeater, i.e. AMR system can read the data in the DDS28u through
maximum 3 levels to the destination, this function improve the reliability of AMR
system a lot.
2. Specification
Rated Voltage
120V, 220V, 230V,
Reference frequency
50Hz or 60Hz
Basic current
20(80)
10(60)
(Maximum)A
3. Technical data
Applicable Standard
IEC 61036-2000
Service Lifetime
10 years
Accuracy Class
Active Class1
Working Temperature
-25℃~+55℃
Max
distance
of
infrared
4m
communication
Distance of PLC
Communication
3km
Starting current
Class 1=0.004Ib
Normal working voltage
0.8Un~1.1Un
Power consumption
=2W、2.5VA
Over voltage protection
Holley Metering Ltd.
6kV
Page 1
Relative humidity
=85%
Dimension of profile
164.5×112×71mm
Net Weight
0.9 kg
4. Functions
4.1) Energy display by LCD, maximum 6 integer and 2 decimal
4.2) Normal and reverse connection energy measurement
4.3) Four tariff and 10 time zone are definable
4.4) PLC data transmission based on CDMA technology on 125kHz Spread Spectrum Carrier.
4.5) Remote control
4.6) Programmable via HHU or PLC
4.7) Anti-tamper functions include reverse connection, short connection and so on.
4.8) Alarm for overload, reverse connection, clock battery low and so on
4.9) Maximal consumption can be limited
4.10)
History data reservation in non-volatile memory.
4.11)
Event records
4.12)
Time synchronization and correction
4.13)
Pulse output
Notes: For the details of the functions, please see the TECHNICAL DESCRIPTION.
5. Outline drawing
71
164.5
112
Holley Metering Ltd.
Page 2
6. Connection Diagram
7
1
L
N
5
2
3
6
4
+脉
-冲
L'
N'
7. Installation
It requires to be mounted indoor on permanent wall, tighten the 3 screws and well connect the
conducting plate in the terminal block. The connection should be according to the diagram curved in
the terminal cover.
8. Guarantee
18 months in case that the meter is sealed and right operation.
Holley Metering Ltd.
Page 3
Download