DDSY283 SINGLE PHASE PREPAYMENT METER 1. General DDSY283 Single phase electronic prepayment meter complies with IEC 61036. The meter adopts micro-electronic technology, has high precision, low power consumption. Depends on adopting large-scale integration (LSI) and surface mounting technology (SMT) as well, by using famous international brand components, it has high reliability and long service life. The meter uses fire-resistant ABS, the structure of the meter is air-proofed, data operation by advanced single-chip processing system. The meter will remind the user to purchase the electricity by alarm when the electricity remained is limited, and cut off the power supply automatically when the electricity use up. It’s also able to limit maximal consuming power, anti-tamper function is optional. Each meter match with one memory card, and the meter can exchange the data with card bi-directionally through the card read device. User won’t lose electricity even he lost the user card, because a renewed card is acceptable. 2. Specification Rated Voltage 120V, 220V, 230V, 240V Reference frequency 50Hz or 60Hz Basic Current (Maximum Current)A 5(20) 10(40) 10(60)A 20(80) 3. Technical data Applicable Standard IEC 61036-2000 Service Lifetime 10 years Accuracy Class Class1, Class2 Working Temperature -10℃~+75℃ Starting current Class 1=0.004Ib; Class 2=0.005Ib. Working Voltage Range 0.7~1.2Un Power consumption =2W、5VA Over voltage protection 6kV Relative humidity =95% 4. Functions ■ Energy display by LCD Holley Metering Ltd. Page 1 ■ Limit maximal consuming power ■ Automatic switch off power when overload ■ Warning when electricity insufficiency ■ Cut off the power when electricity use up ■ Pulse output ■ Operation indicated by pulse LED Optional function: Anti-tamper functio n The DDSY283 with anti-tamper function has extend terminal cover, anti-tamper measurement chipset AD7751 instead of AD7755, and have extra one current transformer except shunt, so there is two measurement loops and the meter will measure energy consumption correctly even current is reversed, details of four situations as following. 1 2 3 LOAD 4 1 2 3 4 P N LOAD N P A ) Load and supply interchange, 1 2 3 P B) phase and neutral connection interchange 1 4 LOAD GND 3 4 N P N 2 LOAD GND C) Load connected with the earth Earth LED: Load earth LED indicator on Holley Metering Ltd. Page 2 1 2 3 LOAD 4 1 2 P 3 4 N LOAD N GND P GND D) Load connected with the earth, current reverse Reverse LED: Current reversal indication on Earth LED: Load earth indication on 5. Working principles The meter collects voltage signals from the potentiometer. The current signals collected from the shunt to get multiplying signals through multiplication device, and after frequency converting, get counting pulses, which is in direct ratio with the product of voltage and current. The counting pulses of electric energy will be sent to CPU for processing through electro-coupling, and be stored in nonvolatile EEPROM after operation. These pulses and information from IC card that been stored with some volume of electricity and data of supervisory demands will be processed by micro processing system in the meter then provide signals of display, warning and cutting-off state etc. Diagram is as follows: Memory Unit Energy Signal Relay Management System Holley Metering Ltd. C P U LCD Display Energy Input/Output IC Card Page 3 165 137 6. Outline drawing 110 65 88 7. Connection Diagram pulse 8. Installation The meter must be connected according to connection diagram curve in the meter. It is required to tighten the screws and well connect the conducting plate in the terminal block. For CT operated meter, the actual volume of electric energy shall be the reading indicated by the meter multiplying the CT ratio. 9. Guarantee 18 months in case that the meter is sealed and right operation. Holley Metering Ltd. Page 4 10. Notes for User 1) 2) 3) 4) 5) 6) 7) One user’s IC card match with one meter only, if the card is lost, the user should buy renewed card from power supply department. Users should insert IC card into the slot in the meter before purchasing, in order to transfer the data of the meter to computer database. When inserting the user IC card into the meter, the meter will verify the user information and LCD will display present purchased electricity, total purchased electricity, times of meter, warning electric ity volume, credit limit, power limit (kW) in sequence. When the meter is working, the LCD will display remain electricity and total consumption by turns. If the "warning LED" illuminate, it means that the user has overload. Power supply will be switched off automatically if it lasts for 30s, and it will be restored automatically within 3 minutes, or may be manually restored by inserting meter card. Warning: when remainder electricity volume is less than twice of "warning volume”, "warning LED" illuminate with an interval of one second, reminding user to purchase electricity. Please purchase additional credit, or insert card to allow use of all remaining credit. Switching-off warning: if remainder electricity volume equals to warning volume, it will switch off power supply. User can resume it by inserting IC card into slot. If user cannot find the card when electricity has been switched off, he may borrow neighbor's card and insert it to resume power supply. 8) Purchase warning: when remained electricity is less than " warning volume “, warning LED will last flash. 9) When remained electricity is zero or negative, it will display " switch off " .The user should purchase electricity at once. Holley Metering Ltd. Page 5