FRANCE Protective Devices Residual Current Devices PFGM (16-100A) • Type -A: Protects against special forms of residual pulsating DC which • Residual Current Devices have have not been smoothed • Shape compatible with and suitable for standard busbar connection to • Type -G: High reliability against unwanted tripping. Compulsory for any other devices of the P-series circuit where personal injury or damage to property may occur in case of • Twin-purpose terminal (lift/open-mouthed) above and below unwanted tripping (ÖVE/ÖNORM E 8001-1 § 12.1.6) • Busbar positioning optionally above or below • Type -G/A: Additionally protects against special forms of residual pulsating • Free terminal space despite installed busbar DC which have not been smoothed. • Universal tripping signal switch, also suitable for PLS., Z-A. can be Special types for X-ray application PFIM-...-R mounted subsequently • Type -S: Selective residual current device sensitive to AC, type -S. • Contact position indicator red - green (PFGM-4-pole) Compulsory for systems with surge arresters downstream of the RCD • Delayed types suitable for being used with standard fluorescent tubes with (ÖVE/ÖNORM E 8001-1 § 12.1.5). or without electronical ballast (30mA-RCD: 30 units per phase conductor, 100mA-RCD: 90 units per phase conductor) Accessories: Notes: Depending of the fluorescent lamp ballast manufacturer partly more Auxiliary switch for possible. Symmetrical allocation of the fluorescent lamp ballasts on all subsequent installation to the left Z-HK 248432 phases favourably. Shifting references of the fluorescent lamp ballast Tripping signal contact for manufacturer consider. subsequent installation to the right Z-NHK 248434 • The device functions irrespective of the position of installation Remote control and • Tripping is line voltage-independent. Consequently, the RCD is suitable for automatic switching device Z-FW/LP 248296 “fault current/residual current protection” and “additional protection” Compact enclosure KLV-TC-2 276240 within the the meaning of the applicable installation rules KLV-TC-4 276241 • Mains connection at either side Sealing cover set Z-RC/AK-2TE 285385 • The 4-pole device can also be used for 3-pole connection. Z-RC/AK-4TE 101062 For this purpose use terminals 1-2, 3-4, and 5-6 (+ cable link). Switching interlock IS/SPE-1TE 101911 • The 4-pole device can also be used for 2-pole connection. For this purpose use terminals 5-6 and N-N. Connection diagrams • The test key “T” must be pressed every 6 month. The system operator 2-pole 4-pole must be informed of this obligation and his responsibility in a way that N/3 1 N/7 1 3 5 can be proven (self-adhesive RCD-label enclosed). • Pressing the test key “T” serves the only purpose of function testing the T T residual current device (RCD). This test does not make earthing resistance measurement (RE), or proper checking of the earth conductor condition N/4 2 N/8 2 4 6 redundant, which must be performed separately. Technical Data Electrical Design according to Voltage range of test button 2-pole 4-pole 30 mA 4-pole 10, 100, 300, 500 mA Endurance electrical comp. mechanical comp. IEC/EN 61008 Type G acc. to ÖVE E 8601 Current test marks as printed onto the device Tripping instantaneous Type G 10 ms delay Type S 40 ms delay with selective disconnecting Rated voltage Un 230/400 V, 50 Hz Rated tripping current IΔn 10, 30, 100, 300, 500 mA Sensitivity AC and pulsating DC Rated insulation voltage Ui 440 V Rated impulse withstand voltage Uimp 4 kV Rated short circuit strength Inc 10 kA Maximum back-up fuse Overvoltage Short circuit In=16A 10A gG/gL 63A gG/gL In=25A 16A gG/gL 63A gG/gL In=40A 25A gG/gL 63A gG/gL In=63A 40A gG/gL 63A gG/gL In the case that the maximal possible operating current of the electrical installation don´t exceed the rated current of the RCD only short circuit protection must be implemented. Overload protection must be implemented in the case if the maximal possible operating current of the electrical installation can exceed the rated current of the RCD. Rated breaking capacity Im or Rated fault breaking capacity IΔm In = 16-40A 500 A In = 63A 630 A Mechanical Frame size Device height Device width Mounting Degree of protection, built-in Deg. of prot. in moisture-proof encl. Upper and lower terminals Terminal protection Terminal capacity Busbar thickness Tripping temperature Storage- and transport temperature Resistance to climatic conditions Dimensions (mm) 2P 5,5 4P 80 30,5 4,5 45 80 10,5 35 70 44 60 1 196-264 VAC 340-456 VAC 196-456 VAC ≥ 4.000 operating cycles ≥ 20.000 operating cycles 45 mm 80 mm 35 mm (2MU),70 mm (4MU) quick fastening with 2 lock-in positions on DIN rail EN50022 IP40 IP54 open mouthed/lift terminals finger and hand touch safe, BGV A3, ÖVE-EN 6 1.5 - 35 mm2 single wire 2 x 16 mm2 multi wire 0.8 - 2 mm -25°C to +40°C -35°C to +60°C 25-55°C/90-95% relative humidity acc. to IEC 60068-2 FRANCE Protective Devices Correct connection 2-pole 30, 100, 300, 500mA Types: N L1 N/3 1 N/4 2 N L1 1+N (230V AC) 4-pole 30mA Types: N L1 L2 L3 N/7 1 3 5 N/8 2 4 6 N L1 L2 L3 3+N (230/400V AC) L1 L2 L3 N/7 1 3 5 N/8 2 4 6 L1 L2 L3 3phase load without N (400V AC Phase-Phase) L1 L2 L3 N L1 N/7 1 3 5 N/7 1 3 5 N/8 2 4 6 N/8 2 4 6 L1 L2 L3 N L1 Not allowed Not allowed 3phase load without N (230V AC Phase-Phase) 2pole (230V AC) 10, 100, 300, 500mA Types: N L1 L2 L3 N/7 1 3 5 N/8 2 4 6 N L1 L2 L3 3+N (230/400V AC) L1 L2 L3 N N/7 1 3 5 N/7 1 3 5 N/8 2 4 6 N/8 2 4 6 L1 L2 L3 N 3phase load without N (230/400V AC Phase-Phase) L1 L1 2pole (230V AC) 2