Dometic Engine-Ventilation Products Catalog

advertisement
INSPIRED BY COMFORT
Ship-Wide Ventilation Systems
Protecting & Cooling Machinery Spaces for Leisure,
Commercial & Military Vessels
Specification Sheets for:
Mist Eliminators, Blowers & Fans, Fire & Smoke Dampers, and Controls
2
Table of Contents
3
4
Mist Eliminators
5
6
Fans & Blowers
Fans & Blowers
7
8
Fans & Blowers
Fans & Blowers
9
10
Fans & Blowers
Fans & Blowers
11
12
Fans & Blowers
Fans & Blowers
13
14
Fans & Blowers
Fans & Blowers
15
16
Fans & Blowers
Fans & Blowers
17
Fans & Blowers
18
DIMENSIONS - F3-360
PERFORMANCE - F3-360
Static Pres [inwg]
5
Power [hp]
4.5
50
40
50 °
4
45 °
3.5
3
25 °
30 °
32.5 °
35 °
37.5 °
30
20
40 °
10
2.5
0
2
1.5
1
0.5
0
25 °
0
500 0
1000 0
1500 0
IMPELLER INFORMATION:
Imp. Diameter:
No of blades:
Pitch:
Blade Material:
Blade Type:
Impeller Rotation:
Mounting:
Bore Diameter:
Key Width:
Boss position:
2000 0
30 °
32.5 °
2500 0
Airflow [cfm]
35 °
37.5 °
3000 0
40 °
3500 0
45 °
4000 0
50 °
4500 0
APPLICATION:
36 in
9
37.5 °
PPG
5Z
L
Speed:
Tip Clearance:
Temperature:
Altitude:
Density:
1750 RPM
0.5 %
95 °F
0 ft
0.07151 lb/ft3
Tests are carried out according to methods described in ANSI / AMCA 210-99
Sound data is calculated and should be used as guideline only
Program: 17.01.2007 Version: 400 (B-052)
50000
Fans & Blowers
19
20
Fans & Blowers
DIMENSIONS
inch
Units: (mm)
ROTATION
AIR
NAME
PLATE
Flange Type
PERFORMANCE
Static Pressure
(Pa)
In H 2 O
300
.12
Ps
60Hz
50Hz
B30
.8
200
B20
B10
.4
100
0
0
2
4
6
(m 3 /min)
CFM
70
141
Air Flow
212
Fans & Blowers
21
22
Fans & Blowers
Fans & Blowers
23
24
Fans & Blowers
25
Fans & Blowers
DIMENSIONS
PERFORMANCE
Input
Power
(W)
A28089V1H
115
1.8/2.5
145/201
2800/3250
1.3/1.1
32/27
37/41
1320/1450 70/74
A28089V2H
230
0.8/1.2
126/193
2800/3250
1.3/1.1
32/27
37/41
1320/1450 70/74
26
Fans & Blowers
Fans & Blowers
27
28
Fans & Blowers
29
Fans & Blowers
FC-3-24
8
3
7
6
2.5
5
2
4
1.5
3
1
LOAD (AMPS)
STATIC PRESSURE (in H2O)
FLOW DATA
3.5
FLOW
2
0.5
AMPS
1
0
0
0
77
89
130
171
212
236
254
271
AIRFLOW (CFM)
FC-3-24H
FLOW DATA
16
6
14
5
10
8
3
6
2
4
1
2
0
0
0
77
89
130
171
212
236
254
271
AIRFLOW (CFM)
289
307
319
330
342
348
LOAD (AMPS)
STATIC PRESSURE (in H2O)
12
4
FLOW
AMPS
30
Fans & Blowers
31
Fans & Blowers
DIMENSIONS
PERFORMANCE
FLOW DATA
3
25
20
2
15
1.5
10
1
5
0.5
0
0
0
100
142
207
254
301
AIRFLOW (CFM)
325
348
384
437
LOAD (AMPS)
STATIC PRESSURE (in H2O)
2.5
FLOW
AMPS
32
Fans & Blowers
33
Fans & Blowers
DIMENSIONS
Units: inch (mm)
PERFORMANCE
34
Fans & Blowers
35
Fans & Blowers
DIMENSIONS - 12 VOLT AND 24 VOLT
8"
[202mm]
6"
[150.97mm]
2"
[50.6mm]
81 4"
[208.95mm]
6"
[150.97mm]
PERFORMANCE
12 VOLT EXHAUST
1.6
9
1.4
8
1.4
8
7
1.2
6
5
0.8
4
0.6
3
0.4
FLOW
AMPS
2
0
0
266
301
330
360
407
3
0.4
0
242
4
0.6
0.2
189
5
0.8
1
118
6
1
0.2
0
7
1.2
1
0
0
118
189
8
6
5
0.6
4
3
0.4
2
0.2
1
0
0
330
AIRFLOW (CFM)
330
360
407
360
407
9
8
FLOW
AMPS
7
1
6
0.8
5
0.6
4
3
0.4
2
0.2
1
0
0
0
118
189
242
266
301
330
AIRFLOW (CFM)
360
407
LOAD (AMPS)
0.8
STATIC PRESSURE (in H2O)
7
1
301
301
1.2
LOAD (AMPS)
STATIC PRESSURE (in H2O)
1.2
266
266
1.4
9
242
242
24 VOLT EXHAUST
24 VOLT INTAKE
189
AMPS
AIRFLOW (CFM)
1.4
118
FLOW
2
AIRFLOW (CFM)
0
LOAD (AMPS)
1
STATIC PRESSURE (in H2O)
9
LOAD (AMPS)
STATIC PRESSURE (in H2O)
12 VOLT INTAKE
1.6
FLOW
AMPS
36
Fans & Blowers
Fans & Blowers
37
38
Fans & Blowers
Fans & Blowers
39
40
Fans & Blowers
Fans & Blowers
41
42
Fans & Blowers
Fans & Blowers
43
44
Fans & Blowers
Fans & Blowers
45
46
Smoke & Fire Dampers
Smoke & Fire Dampers
47
48
Smoke & Fire Dampers
Smoke & Fire Dampers
49
50
Smoke & Fire Dampers
Controls
51
controls
ENGINE ROOM VENTILATION CONTROL
C-EVC3-DC
24 VDC axial fans are often utilized as engine room cooling fans. These relatively inexpensive fans offer
the most efficient flows for a given size. The 24 VDC fans also represent the most reliable option, with failures in
operation a rarity.
The down side to using 24 VDC fans is the noise they generate when running at full load. When cruising
or fishing at low engine RPMs, the noise of the fans can exceed that of the main engines. Livos Technologies has
developed a control that will solve this problem and give the user vast control over the function of 24 VDC
cooling fans.
In automatic mode, the DC fan control will activate the fans at 50% once the engine room reaches a
temperature equal to the set point at the low end of the operating range. This point is set by the user on the lowtemperature thermostat. The fans will increase to 100% when the engine room temperature reaches the set point
at the upper range of the operating range. This point is set by the user on the upper-temperature thermostat.
As the engine room temperature decreases, the fans will return to 50% once the temperature falls below
the upper set point. When the engine room temperature reaches the lower set point, the fans will shut off.
In manual mode, the fans can be operated at 50% or 100%. This is ideal for dockside use where fan noise
becomes a factor, as the noise level at 50% is one-fifth that of 100%.
dometic marine diVision
2000 n. andrews ave. | pompano beach, fl 33069 Usa | tel. 954-973-2477 | fax: 954-979-4414
www.dometic.com/marine | marinesales@dometicUsa.com
51
dometic marine, a division of dometic Group, is the
world’s largest supplier of innovative and technologically
advanced comfort systems and equipment for yachts and
pleasure boats and a major supplier of HVac, engine room
ventilation, and toilet systems to the commercial, workboat
and military markets.
a specialist supplier to oem, refit and repair and
aftermarkets, dometic marine has an unmatched support
network of company-owned offices located in 12 strategic
regions across the globe supported by numerous marine
r&d facilities and factories. the products are further
supported in the field by factory-authorized distributors,
dealers and service engineers offering a global presence
in over 100 countries worldwide.
leisure boats from 20 feet to mega-yachts are users of
the company’s premium brands which include condaria,
cruisair®, dometic, marine air systems®, sealand® and
Waeco. their extensive product range includes marine air
conditioning, engine room ventilation systems, sanitation
systems, refrigerators, stoves, battery chargers and other
equipment for the leisure market.
dometic’s commercial HVac and engine room ventilation
systems can be fitted to the broadest range of commercial
vessels and conform to nmma and asHrae standards;
the company is iso 9001:2008 certified.
Certified Worldwide Sales & Service Network
DOMETIC MARINE
2000 n. andrews ave. ext. | pompano beach, Fl 33069 Usa
tel. 954-973-2477 l Fax 954-979-4414
www.dometicUsa.com l marinesales@dometicUsa.com
24/7 TECHNICAL SUPPORT FOR UNITED STATES & CANADA
8:00 am to 5:00 pm eastern time: 800-542-2477 | after hours and weekends: 888-440-4494
INTERNATIONAL SALES & SERVICE
europe & middle east: call +44(0)870-330-6101
all other areas find the nearest distributor at www.dometic.com/marinedealers
20150123
l–3291 rev. 20140131
Environmentally
Responsible
Assembled in the USA
Download