ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. GDM-8255A/8251A 5 ½ Dual Display Digital Multimeter New Product Announcement GOOD WILL INSTRUMENT is announcing the next generation’s digital multimeter, GDM-8255A / 8251A, to the global market. GDM-8255A/8251A portable precision multi-meters engage with 5 ½ , dual-display, 0.012% DCV accuracy and 2w/4w measurement. The VFD display technology provides the excellent observation of contrast and brightness. GDM-8255A / 8251A carry an extensive list of measurement items - ACV, DCV, ACA, DCA, R, Hz, Continuity beeper, Diode GDM-8255A(199999 Counts) GDM-8251A(120000 Counts) test and Temperature. The dual-display measurement items include ACV + Hz, DCV + dBm, ACV + dBm, DCV + ACV ripple and dBm. Advanced measurement functions, such as Max/Min, Hold, Relative value and Compare, are suitable for multiplicity of applications such as production testing, research and field verification. The USB, RS-232C and 9-pin digital I/O interface are included as standard features, which enable its remote controlling and data capturing for ATE applications. Fast Measurement Speed / Transfer Rate GDM-8255A / 8251A offer selectable measurement speed rate under different modes. The speed rates allow users to maximize the measurement efficiency while maintaining sufficient accuracy. At the fast mode, the instrument delivers 60 readings/sec (see table below), adequately meeting today’s speed demand. Besides, the display could be turned off by pressing OUTPUT ON/OFF button at anytime. By doing so, the operation loading could be reduced and entire running speed could be increased since the unit has been remote controlled and not showing the display. Mode Resolution Measurement Speed Transfer Speed Fast Medium Slow 3 ½ digits 4 ½ digits 5 ½ digits 60 readings/second 30 readings/second 10 readings/second Typical 17mS Typical 34mS Typical 100mS Various Measuring Functions GDM-8255A / 8251A provide 9 major measuring functions such as DCV/ACV, DCI/ACI, 2w/4w Resistance, Diode, Frequency, Continuity test and Temperature. The 0.012% DC voltage accuracy provides user the best measuring precision at the DC voltage applications. In addition, there are several advanced measuring functions such as Max, Min, dB, dBm, REL/REL#, Hold, Compare and Math functions to enhance the serviceability of measuring results. GDM-8200A Series NPI Announcement(USA) 1 OF 10 6/20/2008 ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. 2/ 4 Wire Resistance Measurement GDM-8255A / 8251A offer two methods for resistance measurement. 2-wire resistance measurement is the most common and simplest connection method, typically used in the impedance greater than 1k. 4-wire resistance measurement is required for accurate low impedance measurement. Once the 4-wire measurement is applied, the test lead resistance and contact resistance will be reduced automatically. Combinational Dual Measurement Function GDM-8255A / 8251A offer varieties of dual display combinations with main measurement function which allows GDM-8255A / 8251A to measure two properties of input signals. The dual measuring function will save customers measurement time when dealing with applications requiring multiple parameters simultaneously. Multiple Standard Interfaces GDM-8255A / 8251A provide the standard multiple interfaces for PC connection: RS232C and USB device port. Unlike the common RS232 transfer speed, the GDM-8255A / 8251A even raises the baud rate up to 115200 which would be 12 times faster. It would make the command or data flow faster and smoother. Besides, it is not necessary to expend the fabrication in order to communicate with a PC. It would certainly reduce the user cost. In addition, the digital I/O terminal outputs the result of comparison measurements to control external devices for ATE applications. By providing an independent VCC for the terminal, the digital I/O outputs can also be used as power source for TTL or CMOS logics. Free PC Software – Remote Control & Data Capture For a convenient remote control and a long data capture, the GDM-8255A / 8251A accompanies free software, DMM-Viewer. This software allows users to remotely control the GDM-8255A / 8251A without entering extra commands. Besides, the software interface and even the measurement method resemble those of GDM-8255A / 8251A front panel, thus guaranteeing safe operation and shortened training and program development time. GDM-8200A Series NPI Announcement(USA) 2 OF 10 6/20/2008 ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. For data capturing through a PC, the software allows users to observe measuring result before saving it as a file for further study. In addition, the saved data could be reloaded for converting into a graph. With the DMM-Viewer PC software, the user operation of GDM-8255A / 8251A can be much more effective. Buffer Store / Recall Function GDM-8255A / 8251A provide an internal buffer for storing up to 10,000 counts of measuring data, and it allows users to recall the test records for observation or analyzing the maximum, minimum, or average values after the internal processing is completed. Key Features GDM-8255A : 199999 Counts Display GDM-8251A : 120000 Counts Display VFD, Two Colors Display Selectable Measurement Rate Auto/Manual Ranging True RMS (AC, AC+DC) 2/4 Wire Resistance Measurement Temperature Measurement Frequency Measurement Max./Min., REL, dBm, Compare, Math, Store, Recall, dB Standard USB device, RS232, Digital I/O Interface Compare Specification Colored mark indicates best performance. “X” stands for “no such function” or “function not available”. Features Dual Display Measurements Counts Resolution Meas. Rate True rms DCV Accuracy Measurement Functions DCV ACV GDM-8200A Series NPI Announcement(USA) GDM-8255A Fluke 8808A Agilent 34405A ● 199999 10/30/60 (S/M/F) ● 199999 2.5/20/100 (S/M/F) ● 120000 ---- ● ● ● 0.012% 0.015% 0.025% 9 100mV ~ 1000V In 5 ranges 100mV ~ 750V In 5 ranges. 9 200mV ~ 1000V In 5 ranges 200mV ~ 750V In 5 ranges 10 100mV ~ 1000V In 5 ranges 100mV ~ 750V In 5 ranges. 3 OF 10 6/20/2008 ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. 10mA ~ 10A In 4 ranges 10mA ~ 10A In 4 ranges 100 ~ 100M In 7 ranges Up to 800kHz 200uA ~ 10A In 6 ranges 20mA ~ 10A In 4 ranges 200 ~ 100M In 7 ranges Up to 1MHz 10mA ~ 10A In 4 ranges 10mA ~ 10A In 3 ranges 100 ~ 100M In 7 ranges Up to 300kHz Temperature ● ● ● Continuity Test ● ● ● Diode Test ● ● Capacitance X X Math Functions ● ● ● 1nF ~ 10,000uF In 7 ranges ● Compare Mode ● ● ● 2w / 4w 2 x 4w / 4w 2w Interface (Standard) RS232/USB Device RS232 USB Device Digital I/O (Standard) ● X X Free Charge ● X ● Data Storage & Recall ● X ● Graphical User Interface ● X X DCI ACI Resistance Frequency Resistance Meas. Method PC Software Target Markets and Associated Features R&D 5 ½ digits resolution and 0.012% DCV accuracy for product development. Various functions(ACV, DCV, ACA, DCA, R, Hz, Continuity beeper, Diode test, REL… ) and 2/4 wire resistance, relative and comparing measurement: suitable for wide range of applications Multiple standard interfaces and free PC software for data recording and improved productivity. Quality Assurance Verification ACV, DCV, ACA, DCA, R, Hz, Continuity beeper, Diode test, REL… various functions for wide range of applications The built-in function of 10,000 set measurement record can store the historical measuring data that enables the ability of data recall for purposes of observation and analysis with the Maximum, Minimum, and Average values. Multiple standard interfaces and free PC software for data record of product reliability. Education High 5 ½ digits resolution and measurement 0.012% DCV accuracy for research. Multiple standard interfaces and free PC software for data recording experiment. GDM-8200A Series NPI Announcement(USA) 4 OF 10 6/20/2008 ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. Maintain & Repair Dual display function can deal with application requiring multiple parameters simultaneously. High 5 ½ digits resolution and measurement 0.012% DCV accuracy for circuit debug. ATE System Fast transfer rate with RS232 / USB and Digital I/O multiple standard interfaces plus free PC Software for remote applications Key Dates for Product Announcement 1. Order Queue Open (Middle of May) 2. Distributor Announcement (Middle of May) 3. Global Market Announcement (Middle of May) 4. Demo Units Shipped to Distributors (End of May) 5. Mass Quantity Order Fulfillment (Middle of June) Service Policy 1. 1 year warranty 2. Service Support The service instructions in the Service Manual will help distributors repair defective units promptly. Should the board replacement is necessary to fix the defective unit, the board swapping service support is provided by Good Will Instrument to facilitate the repair jobs done at the distributor’s site. 3. GW Instek continuingly provides the after-sales support through its website. The most up-to-date version of service manual and Marcom material of GDM-8255A/ 8251A will be posted on the distributor zone of GW Instek Website at http://www.gwinstek.com.tw. GDM-8255A Outlook GDM-8200A Series NPI Announcement(USA) GDM-8251A Outlook 5 OF 10 6/20/2008 ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. Specifications General All specifications are ensured only under a single display. At least 30 minutes of warm-up time is required before applying these specifications. Make sure the power ground is connected. Type Digit Fast (F) 3 ½ Digit Medium (M) 4 ½ Digit Slow (S) 5 ½ Digit Ambient Temperature 0°C ~ 40°C, Relative Humidity < 75% (For full accuracy: 18°C ~ 28°C) < 0.15 x applicable accuracy per degree (C°) (for 0°C ~ 18°C and 28°C ~ 40°C) Ambient Temperature −10°C ~ 70°C Relative Humidity: 0°C ~ 35°C < 75%, 35°C ~ 50°C < 50% AC 100–240V ± 10%, 50–60Hz 265(W) x 107(H) x 350(D) mm Approx. 2.6kg without option Note Resolution Operation Environment Temperature Coefficient Storage Environment Power Source Dimension Weight Reading rates (readings/sec) Function Rate DCV DCI ACV ACI 2/4WΩ (10M/100MΩ ) 2/4WΩ (others) ACV+DCV ACI+DCI Diode S 10 10 1 1 1 3 0.3 0.3 30 M 30 30 5 5 1.5 5 0.6 0.6 30 F 60 60 20 20 2 8 1.1 1.1 60 DC Voltage Note Rate S M F Max. Input: 1000V DC or Peak on all range Range Resolution 100.000mV 1.00000V 10.0000V 100.000V 1000.00V 100.00mV 1.0000V 10.000V 100.00V 1000.0V 100.0mV 1.000V 10.00V 100.0V 1000V 1µV 10µV 100µV 1mV 10mV 10µV 100µV 1mV 10mV 100mV 100µV 1mV 10V 100mV 1V GDM-8200A Series NPI Announcement(USA) Full Scale (8251A) 120.000mV 1.20000V 12.0000V 120.000V 1000.00V 120.00mV 1.2000V 12.000V 120.00V 1000.0V 120.0mV 1.200V 12.00V 120.0V 1000V 6 OF 10 Full Scale (8255A) 199.999mV 1.99999V 19.9999V 199.999V 1000.00V 199.99mV 1.9999V 19.999V 199.99V 1000.0V 199.9mV 1.999V 19.99V 199.9V 1000V Accuracy (reading%+digits) 0.012%+8 0.012%+5 0.012%+5 0.012%+5 0.012%+5 0.012%+5 0.012%+5 0.012%+5 0.012%+5 0.012%+5 0.012%+2 0.012%+2 0.012%+2 0.012%+2 0.012%+2 6/20/2008 ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. AC Voltage Note Rate S M F Rate Specifications are for sine wave input > 5% of range (*) Input > 450V only for 30sec, < 200V for 20 ~ 45Hz Resolution 100.000mV 1.00000V 10.0000V 100.000V 750.00V(*) 100.00mV 1.0000V 10.000V 100.00V 750.0V(*) 100.0mV 1.000V 10.00V 100.0V 750V(*) Range 1µV 10µV 100µV 1mV 10mV 10µV 100µV 1mV 10mV 100mV 100µV 1mV 10V 100mV 1V 100.000mV 1.00000V 10.0000V 100.000V 750.00V(*) 100.00mV 1.0000V 10.000V 100.00V 750.0V(*) 100.0mV 1.000V 10.00V 100.0V 750V(*) S M F Full Scale (GDM-8251A) 120.000mV 1.20000V 12.0000V 120.000V 750.00V 120.00mV 1.2000V 12.000V 120.00V 750.0V 120.0mV 1.200V 12.00V 120.0V 750V Accuracy (reading%+digits) 45~10kHz 10k~30kHz 0.2% + 100 1.5% + 300 0.2% + 100 1% + 100 0.2% + 100 1% + 100 0.2% + 100 1% + 100 0.2% + 100 1% + 100 0.2% + 40 1.5% + 80 0.2% + 40 1% + 40 0.2% + 40 1% + 40 0.2% + 40 1% + 40 0.2% + 40 1% + 40 0.2% + 5 1.5% + 10 0.2% + 5 1% + 5 0.2% + 5 1% + 5 0.2% + 5 1% + 5 0.2% + 5 1% + 5 Range 20~45Hz 1% + 100 1% + 100 1% + 100 1% + 100 1% + 100 — — — — — — — — — — Full Scale (GDM-8255A) 199.999mV 1.99999V 19.9999V 199.999V 750.00V 199.99mV 1.9999V 19.999V 199.99V 750.0V 199.9mV 1.999V 19.99V 199.9V 750V 30k~100kHz 5% + 300 3% + 200 3% + 200 3% + 200 3% + 200 5% + 120 3% + 80 3% + 80 3% + 80 3% + 80 5% + 15 3% + 10 3% + 10 3% + 10 3% + 10 DC Current Note Rate S M mA range protected with a 100mA fuse 10A range protected with a 12A, 600V fuse 10A only for 30 seconds Full Scale Range Resolution (GDM-8251A) 10.0000mA 0.1µA 12.0000mA 100.000mA 1µA 120.000mA 1.0000A 100µA 1.9999A 10.0000A 100µA 10.0000A 10.000mA 1µA 12.000mA 100.00mA 10µA 120.00mA 1.000A 1mA 1.999A 10.000A 1mA 10.000A GDM-8200A Series NPI Announcement(USA) 7 OF 10 Full Scale (GDM-8255A) 19.9999mA 199.999mA 1.9999A 10.0000A 19.999mA 199.99mA 1.999A 10.000A Accuracy (reading%+ digits) 0.05%+15 0.05%+5 0.2%+5 0.2%+5 0.1%+6 0.1%+3 0.2%+3 0.2%+3 6/20/2008 ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. 10.00mA 100.0mA 1.00A 10.00A F 10µA 100µA 10mA 10mA 12.00mA 120.0mA 1.99A 10.00A 19.99mA 199.9mA 1.99A 10.00A 0.1%+2 0.1%+2 0.2%+2 0.2%+2 AC Current Note Rate S M F mA range protected with a 100mA fuse 10A range protected with a 12A, 600V fuse *10A range specification is verified for < 5kHz Full Scale Range Resolution (GDM-8251A) 10.0000mA 0.1µA 12.0000mA 100.000mA 1µA 120.000mA 1.0000A 100µA 1.9999A 10.0000A 100µA 10.0000A 10.000mA 1µA 12.000mA 100.00mA 10µA 120.00mA 1.000A 1mA 1.999A 10.000A 1mA 10.000A 10.00mA 10µA 12.00mA 100.0mA 100µA 120.0mA 1.00A 10mA 1.99A 10.00A 10mA 10.00A Accuracy (reading%+digits) Rate Range 10.0000mA 100.000mA S 1.00000A 10.0000A 10.000mA 100.00mA M 1.0000A 10.000A 10.00mA 100.0mA F 1.000A 10.00A 20 ~ 50Hz 1.5% + 100 1.5% + 100 — — — — — — — — — — Full Scale (GDM-8255A) 19.9999mA 199.999mA 1.9999A 10.0000A 19.999mA 199.99mA 1.999A 10.000A 19.99mA 199.9mA 1.99A 10.00A 50 ~ 10kHz 0.5% + 100 0.5% + 100 1% + 100 1% + 100* 0.5% + 40 0.5% + 12 — — 0.5% + 5 0.5% + 2 — — 10k ~ 20kHz 2% + 200 2% + 200 — — 2% + 80 2% + 30 — — 2% + 10 2% + 5 — — Full Scale (GDM-8255A) 199.999Ω 1.99999kΩ 19.9999kΩ 199.999kΩ 1.99999MΩ 19.9999MΩ 199.999MΩ Accuracy (reading%+digits) 0.1% + 8* 0.08% + 5* 0.06% + 5* 0.06% + 5 0.06% + 5 0.3% + 5 3.0% + 8 2W Resistance Note Max. Input: 500V DC or 500V rms AC *: Relative mode Rate Range S 100.000Ω 1.00000kΩ 10.0000kΩ 100.000kΩ 1.00000MΩ 10.0000MΩ 100.000MΩ GDM-8200A Series NPI Announcement(USA) Full Scale (GDM-8251A) 120.000Ω 1.20000kΩ 12.0000kΩ 120.000kΩ 1.20000MΩ 12.0000MΩ 120.000MΩ 8 OF 10 6/20/2008 ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. 100.00Ω 1.0000kΩ 10.000kΩ 100.00kΩ 1.0000MΩ 10.000MΩ 100.00MΩ 100.0Ω 1.000kΩ 10.00kΩ 100.0kΩ 1.000MΩ 10.00MΩ 100.0MΩ M F 120.00Ω 1.2000kΩ 12.000kΩ 120.00kΩ 1.2000MΩ 12.000MΩ 120.00MΩ 120.0Ω 1.200kΩ 12.00kΩ 120.0kΩ 1.200MΩ 12.00MΩ 120.0MΩ 199.99Ω 1.9999kΩ 19.999kΩ 199.99kΩ 1.9999MΩ 19.999MΩ 199.99MΩ 199.9Ω 1.999kΩ 19.99kΩ 199.9kΩ 1.999MΩ 19.99MΩ 199.9MΩ 0.1% + 5* 0.08% + 3* 0.06% + 3 0.06% + 3 0.06% + 3 1.5% + 3 5.0% + 5 0.1% + 2* 0.08% + 2 0.06% + 2 0.06% + 2 0.06% + 2 1.5% + 2 5.0% + 2 4W Resistance Note Rate S M F Max. Input: 500V DC or 500V rms AC Range Full Scale (GDM-8251A) Full Scale (GDM-8255A) Accuracy (reading%+digits) 100.000Ω 1.00000kΩ 10.0000kΩ 100.000kΩ 1.00000MΩ 10.0000MΩ 100.000MΩ 100.00Ω 1.0000kΩ 10.000kΩ 100.00kΩ 1.0000MΩ 10.000MΩ 100.00MΩ 100.0Ω 1.000kΩ 10.00kΩ 100.0kΩ 1.000MΩ 10.00MΩ 100.0MΩ 120.000Ω 1.20000kΩ 12.0000kΩ 120.000kΩ 1.20000MΩ 12.0000MΩ 120.000MΩ 120.00Ω 1.2000kΩ 12.000kΩ 120.00kΩ 1.2000MΩ 12.000MΩ 120.00MΩ 120.0Ω 1.200kΩ 12.00kΩ 120.0kΩ 1.200MΩ 12.00MΩ 120.0MΩ 199.999Ω 1.99999kΩ 19.9999kΩ 199.999kΩ 1.99999MΩ 19.9999MΩ 199.999MΩ 199.99Ω 1.9999kΩ 19.999kΩ 199.99kΩ 1.9999MΩ 19.999MΩ 199.99MΩ 199.9Ω 1.999kΩ 19.99kΩ 199.9kΩ 1.999MΩ 19.99MΩ 199.9MΩ 0.05% + 8 0.05% + 5 0.05% + 5 0.05% + 5 0.05% + 5 0.3% + 5 3.0% + 8 0.05% + 5 0.05% + 3 0.05% + 3 0.05% + 3 0.05% + 3 1.5% + 3 5.0% + 5 0.05% + 2 0.05% + 2 0.05% + 2 0.05% + 2 0.05% + 2 1.5% + 2 5.0% + 2 Diode/Continuity Note Item Diode Continuity Max. Input: 500V DC or 500V rms AC Range 2V, 0.5mA 1 ~ 1000Ω GDM-8200A Series NPI Announcement(USA) 9 OF 10 6/20/2008 ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. Frequency Note Frequency 10Hz ~ 100kHz 100kHz ~ 600kHz 600kHz ~ 800kHz Max. Input: 750V rms or 1000V peak Sensitivity 0.1V 1V 2.5V Accuracy (reading%+digits) 0.05% + 15 0.05% + 3 0.05% + 3 Temperature Note Sensor errors excluded from Temperature specification Type K T J 0.1°C (0 ~ 300°C) Thermo Couple Resolution Measurement Range 0 ~ +300°C 0 ~ +300°C 0 ~ +300°C Ordering information GDM-8255A 5 1/2 ( 199999 counts ) Dual Display Digital Multimeter GDM-8251A 5 1/2 ( 120000 counts ) Dual Display Digital Multimeter Standard Accessories Quick Start User manual x 1 Power cord x 1 Test lead GTL-117 x 1 Calibration key GDM-01 x 1 CD x 1 (including complete user manual, upgrade program and PC software – DMM-Viewer) Optional Accessories GTL-245 USB Cable GTL-232 RS-232C Cable, 9-pin Female to 9-pin, null Modem GTL-108A 4W Type Test lead Should you have any questions on the GDM-8255A / 8251A announcement, please don’t hesitate to contact us Sincerely Yours; Marketing Department Instek America Corp. 3661 Walnut Avenue Chino, CA 91710, U.S.A. Email: sales@instek.com GDM-8200A Series NPI Announcement(USA) 10 OF 10 6/20/2008