Efficiently Maintaining Commercial Buildings… Efficiently Maintaining Commercial Buildings… Guidance Note Regarding: Energy Performance Certificates (EPC), Display Energy Certificates (DEC) And A/C Inspections Hemlow Ltd | Head Office | Suite B | 1st Floor | 1 Suffolk Way | Sevenoaks | Kent | TN13 1YL T: 020 8293 6606 | E: helpdesk@hemlow.com Efficiently Maintaining Commercial Buildings… EPC’s and DEC’s EPC’s will state an asset energy rating for the property, be accompanied by a recommendation report and will be valid for no more than 10 years. These are required for most commercial buildings in excess of 50sq m. DEC's state an operational energy rating and will be valid for 12 months; they are accompanied by an advisory report valid for 7 years. These are required for public buildings. EPC’s are required for most types of buildings, but where a property is occupied by public authorities or institutions providing public services to a large number of persons and frequently visited by those persons (over 1000m2 in floor area) a DEC will be needed. As its name suggests the Certificate has to be clearly displayed perhaps close to the main entrance of Town Halls, libraries, sports centres and similar buildings. To gain an EPC or DEC the property has to be assessed by an accredited energy assessor who has been approved by a body which has gained approval from the secretary of State. The accreditation process has been determined by Department of Communities and Local Government (DCLG) or Scottish Building Standards Agency (SBSA). To calculate an asset rating the government has created and issued a computer tool called SBEM – Simplified Building Energy Model. There are a number of modelling tools and simulation models, but it is worth noting that to produce a DEC, twelve months actual energy use is required using billing or meter reading data. On the EPC and DEC there will be an energy performance asset rating showing how energy efficient the building is using a colour coded diagram. See below: Hemlow Ltd | Head Office | Suite B | 1st Floor | 1 Suffolk Way | Sevenoaks | Kent | TN13 1YL T: 020 8293 6606 | E: helpdesk@hemlow.com Efficiently Maintaining Commercial Buildings… More Energy Efficiency Net zero CO2 emissions Less Energy Efficiency Benchmark>> There are benchmarks included to show the comparisons with buildings similar to the one being rated. These are replicated below: If newly built If typical of the existing stock Hemlow Ltd | Head Office | Suite B | 1st Floor | 1 Suffolk Way | Sevenoaks | Kent | TN13 1YL T: 020 8293 6606 | E: helpdesk@hemlow.com Efficiently Maintaining Commercial Buildings… Technical Information The EPC also has some technical information included: Main heating fuel: Example – Natural Gas Building Environment: Example – Air Conditioning Total useful floor area (m2): Numerical Figure Building complexity: Numerical Figure (NOS Level) A/C INSPECTIONS Air Conditioning (AC) inspections form the final part of the implementation of The Energy Performance of Buildings (Certificates and Inspections) (England and Wales) Regulations 2007. The requirement for regular inspections is a statutory obligation for owners or occupiers who control AC systems that serve a building or part of a building. All AC systems with rated outputs over 12kW require an inspection by an Energy Assessor, at intervals no greater than 5 years. Inspections by Energy Assessors are intended to improve efficiency and reduce energy consumption, operating costs and carbon emissions for AC systems. Implementation Dates The first inspection of AC systems under the Regulations to be carried out as follows: st For all systems first put into service on or after 1 January 2008, the first inspection must have taken place within 5 years of the date when it was first put into service. For other AC systems, where the effective rated output are more than 250kW the first inspection must th happen before 4 January 2009. For other AC systems, where the effective rated output are more than 12kW the first inspection must happen before 4th January 2011. Key Points Hemlow Ltd | Head Office | Suite B | 1st Floor | 1 Suffolk Way | Sevenoaks | Kent | TN13 1YL T: 020 8293 6606 | E: helpdesk@hemlow.com Efficiently Maintaining Commercial Buildings… The inspections have to be undertaken by Accredited Energy Assessors, who have passed the relevant training and have the knowledge and experience to issue a report on AC systems. Tenants will be responsible for AC systems that they own and operate themselves. The inspection will examine not only the refrigeration systems, but also the air movement and controls that form the whole AC system, and so will require a full site survey. The inspection report will provide basic information regarding the efficiency of the AC system, together with advice on how to improve energy efficiency or effectiveness of the AC system. Indicative inspection costs for AC systems over 250kW range from £1,500 to £3,500 plus VAT depending on the floor area and size/complexity of the AC system. It should be noted that these indicative costs are for a basic report, and may change depending upon further government updates and suppliers’ increasing experience of producing report for AC systems. The penalty for failing to have a report when required is fixed at £300. As with EPCs, local authority Trading Standards Officers will be responsible for enforcement. Key Dates 6th April 2008 EPC's required on construction of all residential dwellings. EPC's required for the construction, sale or rent of buildings, other than dwellings with a floor area over 2 10,000m . 1st July 2008 2 EPC's required for construction, sale or rent of buildings other than dwellings with a floor area over 2500m . 1st October 2008 EPC's required for the construction, sale or rent of all remaining buildings in excess of 50sq m other than dwellings. 2 DEC's required for all public buildings greater than 10,000m . 1st January 2009 The first inspection of all existing AC systems over 250KW must have occurred by this date (or with 5 Years of installation if installed after 1st January 2008) Market Analysis Hemlow Ltd | Head Office | Suite B | 1st Floor | 1 Suffolk Way | Sevenoaks | Kent | TN13 1YL T: 020 8293 6606 | E: helpdesk@hemlow.com Efficiently Maintaining Commercial Buildings… The EPC's and DEC's are being offered by 3 main groups of people; Risk Assessors, Energy Advisors and M&E Consultants. Some agents feel this is a purely a sales and lettings issue and will be better carried out by a risk assessor type company. Some feel that an M&E consultancy is better placed to provide the assessment as their main recommendations are likely to involve main plant and other service issues. Energy assessors may not be able to offer broad enough advice to identify problems and suggest remedies. A list of recommended companies can be found on the CIBSE website; guidelines of typical costs are as follows: 50 – 1000m 2 1000 – 2500m £ 900 - £1,200 2 £2,000 - £3,500 2 £4,500 - £7,000 10,000m & over £9,000 - £15,000 2500 – 10,000m 2 AC inspections are being offered by consultants and contractors. The market tends to favour consultants on the basis that the contractor could have a vested interest in providing information that supports his maintenance regime. However AC inspections will require specialist knowledge and probably the combined efforts of contractor and consultant will be needed to fulfil the TM44 requirements. Landlords with small property portfolios and their agents will have an expectation that the incumbent maintenance contractor is best placed to provide this inspection and view this as an addition to their current maintenance programme. Our View Hemlow Ltd | Head Office | Suite B | 1st Floor | 1 Suffolk Way | Sevenoaks | Kent | TN13 1YL T: 020 8293 6606 | E: helpdesk@hemlow.com Efficiently Maintaining Commercial Buildings… The market place is currently short of assessors and a postponement until 4th January 2009 has already been granted. However many varied companies will jump on the bandwagon but this will calm down and the market will determine the most suitable companies. We think the market is likely to favour the M&E consultant route due to his better knowledge of the fabric and plant within the building and independent status. It is possible the current key dates will slip further and that Landlord and their agents will have to show some form of commitment until the market has caught up with the backlog. There has been an initial postponement until 4th January 2009 and others may follow. We should offer best advice to our clients at all times and advise that M&E consultants are probably the best producer of EPC's and DEC's, this is based on their more detailed knowledge of building fabric and main plant. With a good contractor by their side who understands what is required, the client is more likely to get a better report. We should supply an approved TM44 assessor to be able to carry out AC inspections and offer this service to those clients who will want the contractor to carry out the work directly. We should also support our M&E consultant when the client wants a more independent approach. There is a general view that it will be difficult to raise the efficiency rating of the existing building stock as the majority of efficiency improvement will come from improved building fabric. However chiller replacements and heating efficiencies are bound to be more carefully considered and we should offer environmental options wherever possible. Suitable individuals within the company will be identified to take the appropriate CIBSE recommended course. Hemlow Ltd | Head Office | Suite B | 1st Floor | 1 Suffolk Way | Sevenoaks | Kent | TN13 1YL T: 020 8293 6606 | E: helpdesk@hemlow.com