Realta | Luminaires | Products | Thorlux Lighting Global Page 1 of 1 You are logged in as Andrew Howard | My Thorlux | Logout | Realta Description Gallery Documents Photometry High performance luminaires designed to minimise light pollution and energy consumption Stylish IP66 wall mounted luminaires. Die-cast aluminium body with a choice of high efficiency glass or polycarbonate refractor. Less than 2% upward light. 18W LED, 32W LED and 42W TC-T versions. Applications: Wide versions ideal for uniform pathway lighting for schools, hospitals, retail and other commercial environments. 32W LED version ideal for general area lighting requiring a forward throw light distribution. Realta Micro also available for low light level applications or emergency exit lighting. Accept Cookies | Find Out More You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 08/10/2014 http://www.thorlux.com/luminaires/realta?type=exterior&lamp-type=led LEDbar ACCESSORIES DESCRIPTION CAT. No. PATENT APPLIED FOR APPROX. kg Single luminaire pole mounting attachment (for 60m dia. poles) RL 13759 1.6 Twin luminaire pole mounting attachment (for 60m dia. poles) RL 14175 2.6 GLB 11184 0.8 76/60mm dia. spigot adaptor (for retro-fit on 76mm dia. columns) Single luminaire pole mounting attachment The LEDbar substitutes the conventional Realta lamp source with an 18W LED lamp package. The aluminium bar dissipates the heat generated by the LEDs for optimum performance. 210 Twin luminaire pole mounting attachment www.thorlux.com/exterior Sept. ‘13 High performance luminaires designed to minimise light pollution and energy consumption IP66 IK10++ / IK10 / IK06 TC-T REALTA LED SPECIFICATION Graphite full polyester powder finish. Silver option l l Strong die-cast LM2 aluminium body High efficiency prismatic polycarbonate l or borosilicate glass front refractor l LED versions with excellent performance Wide distribution (18W LED & 42W TC-T) or area distribution (32W LED) options l Highly specular, multi-faceted injection moulded vacuum metallised reflector l Excellent distribution with less than 2% upward light component l l Wide distribution Optional photocell control TC-T versions with high frequency tri-lamp ballast enables retro-fit of 26 and 32W lamps Area distribution l l Realta Design Registration Number 3024955 Conventionally switched and Smart External versions RANGE Fitted with 4000K lamp(s) or 5000K LEDs (18W) and 5700K LEDs (32W) l LAMP For LED characteristics explanation see www.thorlux.com/led-characteristics IK10 Polycarbonate Cover 18W LED RL 14437D 3.9 32W LED RL 15850D4.0 IKIK10++ Polycarbonate Cover 18W LED RL 14436L 3.8 32W LED RL 15849L3.9 42W TC-T STANDARD 32W LED CHARACTERISTICS Ra °K L70/B10 P/U % R/Rx PF LL/CW 65 5700 60K P >88 R >0.95 73.0 SMART EXTERNAL 18W LED CHARACTERISTICS Ra °K L70/B10 P/U % R/Rx PF LL/CW 65 5000 60K P >85 R >0.95 Poly - 61.9 Glass - 52.4 WIDE AREAAPPROX. DISTRIBUTION DISTRIBUTION kg RL 13535J 3.6 IK06 Glass Cover 18W LED RL 14438L 4.6 42W TC-T RL 13528J 4.5 OPTIONS DESCRIPTION SUFFIX EXAMPLE CIRCUIT TYPE - J - non-dimming (HF fluorescent) / L - non-dimming (LED) Smart External versions use digital dimming gear and are always suffixed D Photocell (standard versions only) Tamper resistant screws u PC RL 14436LPC T RL 14436T SILVER OPTION - add suffix SV3 e.g. RL 14437DSV3 etc. u To fasten tamper resistant screws order EMERGENCY VERSION - prefix catalogue number with: ERL - Emergency / TRL - AutoTest / DRL - Scanlight AT e.g. ERL 15850D etc. Emergency, AutoTest and Scanlight AT versions add 0.4kg to weights listed special screwdriver KEY 10008 Lamp version emergency operation is provided by a sustained emergency lamp (fitted) - 5W TC-S 42W TC-T versions use electronic control gear Web Link: Smart External System Sept. ‘13 www.thorlux.com/exterior211 REALTA PHOTOMETRIC GUIDE PERFORMANCE GUIDE - Wide Distribution POLYCARBONATE COVER - 42W TC-T (Wide Distribution) Photometric Performance 18W LED with polycarbonate cover D.L.O.R. 55% Spacing U.L.O.R. 2% SPACING AVERAGEUNIFORMITY ILLUMINANCE (min/av) 3m mounting height - 3m forward throw 120 240 360 18 lux 12 lux 10 lux 0.53 0.49 0.35 Mounting height 4m mounting height - 4m forward throw CANDELAS PER 1000 LUMENS POLYCARBONATE COVER - 18W LED (Wide Distribution) D.L.O.R. 98% 10m ctrs 15m ctrs 20m ctrs 10m ctrs 15m ctrs 20m ctrs 15 lux 9 lux 7 lux 0.64 0.55 0.49 Forward throw U.L.O.R. 2% e.g. At 3m mounting height and 10m centres: 18 lux average horizontal illuminance at ground level 5m mounting height - 5m forward throw 10m ctrs 15m ctrs 20m ctrs 10 lux 7 lux 5 lux 0.56 0.49 0.55 300 FIGURES ARE BASED ON INITIAL LUMENS 600 900 CANDELAS PER 1000 LUMENS Luminaire Lumen Output 18W = 1430lm ENERGY SAVINGS COMPARISON - Installation of 25 luminaires POLYCARBONATE COVER - 32W LED (Area Distribution) D.L.O.R. 98% U.L.O.R. 2% 120 18W LED 42W CFL SMART SAVING Circuit (W) 4724 23 Burn hours per annum 4,3801,095 s 3,285 Annual kWh 5,1471,314 3,833 CO2 (kg) Cost n 240 s n 360 2,728696 2,032 £617.58£78.84 £538.74 On-time reduced due to Smart presence detection Based on 12p/kWh CANDELAS PER 1000 LUMENS Luminaire Lumen Output 32W = 2700lm 25 YEAR LIFE COSTING ANALYSIS - Installation of 25 luminaires 18W LED 42W CFL SMART SAVING 1250 125 Number of lamps replaced Total cost of relamping s £17,913£0 £17,913 Power usage for site (kWh) 128,66332,850 95,813 Electricity cost s n £25,719£3,283 £22,436 68,43017,560 50,970 6918 51 CO2 (kg) Number of trees required to absorb CO2 produced Based on inflation rate of 4% each year (includes travelling, access equipment, re-lamping and labour for 2 maintenance engineers) n Based on 12p/kWh s 212 www.thorlux.com/exterior Sept. ‘13 REALTA LED version - area distribution LED version - wide distribution DIMENSIONS Spot marked for side entry on both sides. Customer to drill if required. Photocell location 18 Photocell location 220 318 1 x 20 dia. cable entry hole (IP66 grommet supplied) 3 x 6.5 dia. holes 290 266 157 100 262 Sept. ‘13 360 248 www.thorlux.com/exterior213