Realta

advertisement
Realta | Luminaires | Products | Thorlux Lighting Global
Page 1 of 1
You are logged in as Andrew Howard | My Thorlux | Logout |
Realta
Description
Gallery
Documents
Photometry
High performance luminaires designed to
minimise light pollution and energy
consumption
Stylish IP66 wall mounted luminaires. Die-cast aluminium
body with a choice of high efficiency glass or polycarbonate
refractor. Less than 2% upward light. 18W LED, 32W LED and
42W TC-T versions.
Applications: Wide versions ideal for uniform pathway lighting
for schools, hospitals, retail and other commercial
environments. 32W LED version ideal for general area lighting
requiring a forward throw light distribution.
Realta Micro also available for low light level applications or
emergency exit lighting.
Accept Cookies | Find Out More
You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 08/10/2014
http://www.thorlux.com/luminaires/realta?type=exterior&lamp-type=led
LEDbar
ACCESSORIES
DESCRIPTION
CAT. No.
PATENT
APPLIED
FOR
APPROX.
kg
Single luminaire pole mounting
attachment (for 60m dia. poles)
RL 13759
1.6
Twin luminaire pole mounting
attachment (for 60m dia. poles)
RL 14175
2.6
GLB 11184
0.8
76/60mm dia. spigot adaptor
(for retro-fit on 76mm dia. columns)
Single luminaire pole mounting attachment
The LEDbar substitutes the
conventional Realta lamp source
with an 18W LED lamp package.
The aluminium bar dissipates
the heat generated by the LEDs
for optimum performance.
210 Twin luminaire pole mounting attachment
www.thorlux.com/exterior
Sept. ‘13
High performance luminaires designed to minimise
light pollution and energy consumption
IP66 IK10++ / IK10 / IK06
TC-T
REALTA
LED
SPECIFICATION
Graphite full polyester powder finish.
Silver option
l
l
Strong die-cast LM2 aluminium body
High efficiency prismatic polycarbonate
l
or borosilicate glass front refractor
l
LED versions with excellent performance
Wide distribution (18W LED & 42W TC-T)
or area distribution (32W LED) options
l
Highly specular, multi-faceted injection
moulded vacuum metallised reflector
l
Excellent distribution with less than
2% upward light component
l
l
Wide distribution
Optional photocell control
TC-T versions with high frequency
tri-lamp ballast enables retro-fit
of 26 and 32W lamps
Area distribution
l
l
Realta Design Registration Number 3024955
Conventionally switched and
Smart External versions
RANGE
Fitted with 4000K lamp(s) or 5000K LEDs
(18W) and 5700K LEDs (32W)
l
LAMP
For LED characteristics explanation see
www.thorlux.com/led-characteristics
IK10 Polycarbonate Cover
18W LED RL 14437D 3.9
32W LED
RL 15850D4.0
IKIK10++ Polycarbonate Cover
18W LED
RL 14436L 3.8
32W LED
RL 15849L3.9
42W TC-T
STANDARD
32W LED CHARACTERISTICS
Ra °K L70/B10 P/U % R/Rx PF LL/CW
65
5700 60K
P >88 R >0.95 73.0
SMART EXTERNAL
18W LED CHARACTERISTICS
Ra °K L70/B10 P/U % R/Rx PF LL/CW
65 5000 60K
P >85 R >0.95 Poly - 61.9
Glass - 52.4
WIDE AREAAPPROX.
DISTRIBUTION DISTRIBUTION
kg
RL 13535J
3.6
IK06 Glass Cover
18W LED
RL 14438L
4.6
42W TC-T
RL 13528J
4.5
OPTIONS
DESCRIPTION
SUFFIX EXAMPLE
CIRCUIT TYPE - J - non-dimming (HF fluorescent) / L - non-dimming (LED)
Smart External versions use digital dimming gear and are always suffixed D
Photocell (standard versions only)
Tamper resistant screws u
PC
RL 14436LPC
T
RL 14436T
SILVER OPTION - add suffix SV3
e.g. RL 14437DSV3 etc.
u To fasten tamper resistant screws order
EMERGENCY VERSION - prefix catalogue number with:
ERL - Emergency / TRL - AutoTest / DRL - Scanlight AT e.g. ERL 15850D etc.
Emergency, AutoTest and Scanlight AT versions add 0.4kg to weights listed
special screwdriver KEY 10008
Lamp version emergency operation is provided by a sustained emergency lamp (fitted) - 5W TC-S
42W TC-T versions use electronic control gear
Web Link: Smart External System
Sept. ‘13
www.thorlux.com/exterior211
REALTA
PHOTOMETRIC GUIDE
PERFORMANCE GUIDE - Wide Distribution
POLYCARBONATE COVER - 42W TC-T
(Wide Distribution)
Photometric Performance 18W LED with polycarbonate cover
D.L.O.R. 55%
Spacing
U.L.O.R. 2%
SPACING
AVERAGEUNIFORMITY
ILLUMINANCE
(min/av)
3m mounting height - 3m forward throw
120
240
360
18 lux
12 lux
10 lux
0.53
0.49
0.35
Mounting
height
4m mounting height - 4m forward throw
CANDELAS PER 1000 LUMENS
POLYCARBONATE COVER - 18W LED
(Wide Distribution)
D.L.O.R. 98%
10m ctrs
15m ctrs
20m ctrs
10m ctrs
15m ctrs
20m ctrs
15 lux
9 lux
7 lux
0.64
0.55
0.49
Forward throw
U.L.O.R. 2%
e.g. At 3m mounting height and
10m centres: 18 lux average
horizontal illuminance
at ground level
5m mounting height - 5m forward throw
10m ctrs
15m ctrs
20m ctrs
10 lux
7 lux
5 lux
0.56
0.49
0.55
300
FIGURES ARE BASED ON INITIAL LUMENS
600
900
CANDELAS PER 1000 LUMENS
Luminaire Lumen Output
18W = 1430lm
ENERGY SAVINGS COMPARISON - Installation of 25 luminaires
POLYCARBONATE COVER - 32W LED
(Area Distribution)
D.L.O.R. 98%
U.L.O.R. 2%
120
18W LED
42W CFL
SMART
SAVING
Circuit (W)
4724
23
Burn hours per annum
4,3801,095 s
3,285
Annual kWh
5,1471,314
3,833
CO2 (kg)
Cost n
240
s
n
360
2,728696
2,032
£617.58£78.84
£538.74
On-time reduced due to Smart presence detection
Based on 12p/kWh
CANDELAS PER 1000 LUMENS
Luminaire Lumen Output
32W = 2700lm
25 YEAR LIFE COSTING ANALYSIS - Installation of 25 luminaires
18W LED
42W CFL
SMART
SAVING
1250
125
Number of lamps replaced
Total cost of relamping s
£17,913£0
£17,913
Power usage for site (kWh)
128,66332,850
95,813
Electricity cost s n
£25,719£3,283
£22,436
68,43017,560
50,970
6918
51
CO2 (kg)
Number of trees required
to absorb CO2 produced
Based on inflation rate of 4% each year (includes travelling, access
equipment, re-lamping and labour for 2 maintenance engineers)
n Based on 12p/kWh
s
212
www.thorlux.com/exterior
Sept. ‘13
REALTA
LED version
- area distribution
LED version
- wide distribution
DIMENSIONS
Spot marked for
side entry on
both sides.
Customer
to drill if
required.
Photocell
location
18
Photocell
location
220
318
1 x 20 dia.
cable entry
hole (IP66
grommet
supplied)
3 x 6.5 dia. holes
290
266
157
100
262
Sept. ‘13
360
248
www.thorlux.com/exterior213
Download