CL-152 -- Precision Measurement Equipment, Inc.(Orange, CA)

advertisement
This is to attest that
PRECISION MEASUREMENT EQUIPMENT, INC.
1584 NORTH BATAVIA STREET, SUITE 1
ORANGE, CALIFORNIA 92867
Calibration Laboratory CL-152
has met the requirements of the IAS Accreditation Criteria for Calibration Laboratories (AC204), has demonstrated compliance with the ISO/IEC
Standard 17025:2005, General requirements for the competence of testing and calibration laboratories, and has been accredited commencing
December 14, 2015, for the calibration discipline(s) listed in the approved scope of accreditation. The laboratory meets IAS program requirements in
the field of calibration.
(see laboratory’s scope of accreditation for fields of calibration and accredited calibration methods)
This accreditation certificate supersedes any IAS
accreditation bearing an earlier effective date. The
certificate becomes invalid upon suspension, cancellation
or revocation of accreditation.
See http://iasonline.org/More/search.html for current
accreditation information, or contact IAS at 562-364-8201.
C.P. Ramani, P.E., C.B.O
President
IAS Accreditation Number
Accredited Entity
Address
CL-152
Precision Measurement Equipment, Inc.
1584 N. Batavia St. Suite 1
Orange, CA 92867
Johnathan Brown, VP Operations
714-418-1444
December 14, 2015
Contact Name
Telephone
Effective Date of Scope
MEASUREMENT AREA
CALIBRATION &
MEASUREMENT
1
CAPABILITY (CMC) (±)
Electrical DC/Low Frequency
RANGE & RESOLUTION
Electrical DC/LF
DC Voltage - Measure
DC Current - Measure
Resistance - Measure
DC Voltage - Generate
DC Current - Generate
(0 to 100) mV
(> 0.1 to 1) V
(> 1 to 10) V
(> 10 to 100) V
(> 100 to 1,000) V
(0 to 100) µA
(> 0.1 to 1) mA
(>1 to 10) mA
(> 10 to 100) mA
(> 0.1 to 1) A
(0 to 10) Ω
(> 10 to 100) Ω
(> 0.1 to 1) kΩ
(> 1 to 10) kΩ
(> 10 to 100) kΩ
(> 0.1 to 1) MΩ
(> 1 to 10) MΩ
(> 10 to 100) MΩ
(0 to 330) mV
(> 0.33 to 3.3) V
(> 3.3 to 33) V
(> 33 to 330) V
(> 330 to 1,000) V
(0 to 330) µA
(> 0.33 to 3.3) mA
(> 3.3 to 33) mA
(> 0.33 to 330) mA
(> 0.33 to 1.1) A
(> 1.1 to 11) A
(> 11 to 20) A
Resistance - Generate
(0 to 11) Ω
(> 11 to 33) Ω
(> 33 to 110) Ω
(> 110 to 330) Ω
(> 0.33 to 1.1) kΩ
(> 1.1 to 3.3) kΩ
(> 3.3 to 11) kΩ
(> 11 to 33) kΩ
Expressed As Uncertainty at
k=2 (±)
3.5 µV/V
2.3 µV/V
1.2 µV/V
3.7 µV/V
2.8 µV/V
7.5 µA/A
5.5 µA/A
7.8 µA/A
12 µA/A
34.1 µA/A
6.5 µΩ/Ω
3.4 µΩ/Ω
2.4 µΩ/Ω
3.5 µΩ/Ω
4.2 µΩ/Ω
9.6 µΩ/Ω
14 µΩ/Ω
75 µΩ/Ω
1.7 µV
9.8 µV
105 µV
1.2 mV
3.5 mV
4 nA
36 nA
0.4 µA
6.7 µA
250 µA
710 µA
2.2 mA
Expressed As Uncertainty at
k=2 (±)
112 µΩ
220 µΩ
580 µΩ
1.9 mΩ
5.9 mΩ
32 mΩ
85 mΩ
0.310 Ω
TECHNIQUE, REFERENCE
STANDARD, EQUIPMENT
HP 3458A
HP 3458A
HP 3458A (4-Wire)
Fluke 5520A/SC 1100
Fluke 5520A/SC 1100
Fluke 5520A/SC 1100 (4Wire)
Page 2 of 3
CL-152, Precision Measurement Equipment, Inc.
MEASUREMENT AREA
Electrical DC/LF (continued)
Resistance - Generate
RANGE &
RESOLUTION
CALIBRATION &
MEASUREMENT
1
CAPABILITY (CMC) (±)
(>33 to 110) kΩ
(> 110 to 330) kΩ
(> 0.33 to 1.1) MΩ
(> 1.1 to 3.3) MΩ
(> 3.3 to 11) MΩ
(> 11 to 33) MΩ
(> 33 to 110) MΩ
(> 110 to 330) MΩ
(> 330 to 1,100) MΩ
0.86 Ω
2.5 Ω
7.2 Ω
42 Ω
250 Ω
2.1 kΩ
10 kΩ
84 kΩ
1.3 MΩ
TECHNIQUE, REFERENCE
STANDARD, EQUIPMENT
Fluke 5520A/SC 1100 (2Wire)
1
“Calibration and Measurement Capability” is the smallest uncertainty of measurement that a laboratory can achieve within its scope of
accreditation when performing more or less routine calibrations of nearly ideal measurement standards or of nearly ideal measuring
instruments. Calibration and Measurement Capabilities are expressed as uncertainties at approximately the 95% level of confidence, usually
using a coverage factor of k=2. The measurement uncertainty of a specific calibration performed by the laboratory may be greater than the
least uncertainty due to the behavior of the customer’s device, to the environment (if the calibration is performed in the field), and to influences
from the circumstances of the specific calibration.
Page 3 of 3
CL-152, Precision Measurement Equipment, Inc.