Series
Power Supply Center
Made in USA
Q6 Series Table of Contents
Q-TRAN, INC.
155 Hill Street
Milford, CT 06460
P: (203) 367-8777
F: (203) 367-8771
www.Q-Tran.com
The Q-Tran product family
is made up of 6 product series, for a variety of installation
demands. From outdoor applications to direct burial units
to recessed units. Q-Tran’s product family is sure to have
the right model for any job. Please refer to the Product
Matrix located on page 10.
Q-Tran Product Matrix ................. Page 10
Table Of Contents
Page 2
Q6 Features and Benefits ...........
Page 3
Q6S Model .................................... Page 4
Q6M Model ................................... Page 5
Page 6
Q-Tran Ordering Guide ...............
Page 7
Q-Tran Ordering Guide Help .......
Page 8
Quieter. Brighter. Better. .............
Page 9-10
Q-Tran Product Matrix .................
Page 10
1
© Copyright Q-Tran, Inc. 2010
© Copyright Q-Tran, Inc.
Q-Tran’s Quality and History
Q6 Series Introduction ................
Q6L Model ....................................
Transformers
Q-Tran was the first company to develop a
Power Supply Center (PSC) designed
specifically for Low Voltage Lighting. The
PSC address and solves all of the problems
created by Low Voltage Lighting Systems.
Q-Tran transformers are designed and
manufactured to the highest quality,
and live tested 3 times before leaving our
facility. Q-Tran uses the best equipment,
material and designs for all of our products,
allowing for the quietest and most efficient
transformers available in the marketplace.
The benefits include:
Multi Tap - Dual Tap
Higher Efficiency
Compensation for Voltage Drop
Energy Savings
Performance
Safety
Quieter Transformers
Longevity, including a 10-year warranty
Mounting Flexibility
Q6 Series Power Supply Center (PSC)
50W - 1800W
The Q6 Series has a
unique dual tap design to
compensate for voltage drop,
a standard choke for noise
reduction and in-rush current, as well as Q-Tran quality
at competetive prices. The Q6 offers 6 different
mounting positions and 3 different mounting options.
Each Q6 unit comes standard with secondary circuit
protection.
Primary Voltage
120 (60Hz)
230 (50/60Hz)
Transformer Secondary Voltage
12V or 24V
12V or 24V
277 (60Hz)
Rated Volts
12V
24V
Max Volts
Product Testing
13V
26V
The Q6S
is 18 Guage welded steel
measuring 8.63”L x 5.75”W x 3.1”H with 4
knockouts. Standard finish is white powder coat.
The Q6S comes with a choke (150W - 300W only)
and secondary circuit breakers.
Model
Max Lamp
Load (Watts)
Q6S - 50DT
Q6S - 100DT
Q6S - 150DT
Q6S - 300DT
50W
100W
150W
300W
PSC
Max PSC
Efficiency Rating (Watts)
92%
92%
92%
92%
54W
108W
163W
324W
Max PSC
Load (VA)
Max Prim.
Amps@120V
Max Prim.
Amps@277V
58
115
173
345
0.5A
1.0A
1.4A
2.9A
0.2A
0.4A
0.62A
1.2A
Number of Secondary Breakers
3
Up to three secondary circuit breakers can be used
The Q6M is 18 Guage welded steel
measuring 11”L x 7”W x 4.5”H with 6
knockouts. Standard finish is white powder
coat. The Q6M comes with a choke and
secondary circuit breakers.
© Copyright Q-Tran, Inc.
Model
Max Lamp
Load (Watts)
Q6M - 500DT
Q6M - 600DT
Q6M - 750DT
500W
600W
750W
PSC
Max PSC
Efficiency Rating (Watts)
94%
94%
94%
530W
638W
795W
Max PSC
Load (VA)
Max Prim.
Amps@120V
Max Prim.
Amps@277V
575
690
863
4.7A
5.7A
7.1A
2.0A
2.4A
3.0A
Number of Secondary Breakers
5
Up to five secondary circuit breakers can be used
The Q6L
is 18 Guage welded steel
measuring 15”L x 10”W x 5.25”H with 11
knockouts. Standard finish is white powder
coat. The Q6L comes with a choke and
secondary circuit breakers.
Model
Q6L - 900DT
Q6L - 1050DT
Q6L - 1200DT
Q6L - 1500DT
Q6L - 1800DT
Max Lamp
Load (Watts)
900W
1050W
1200W
1500W
1800W
PSC
Max PSC
Efficiency Rating (Watts)
95%
95%
95%
95%
96%
945W
1102W
1260W
1575W
1863W
Max PSC
Load (VA)
Max Prim.
Amps@120V
Max Prim.
Amps@277V
1035
1208
1380
1725
2070
8.4A
9.8A
11.2A
14.0A
16.0A
3.7A
4.2A
4.9A
6.1A
7.0A
Number of Secondary Breakers
9
Up to nine secondary circuit breakers can be used
Q6 Options, include a junction box mounting plate,
and suspension rod.
Q-Tran Building
Q6 Wall Installation
For more information and complete specs,
please see the ordering guide or visit www.Q-Tran.com
© Copyright Q-Tran, Inc. 2010
2
Q6 Series Power Supply Center (PSC)
50W - 1800W
The Q6 Series is the first and only transformer designed and UL
listed to be mounted in 6 positions. Typical transformers are only UL listed to be
mounted in the vertical position, but the Q6 allows flexibility of mounting the
transformer in any of 6 positions. The Q6 also offers dual taps to compensate
for voltage drop, a standard choke to reduce noise and in-rush current, as
well as Q-Tran quality at a competetive price. Other features and benifits
include a 10-year warranty, 95% + efficiency, safety along with different
mounting features including rod suspension and an optional J-Box
mounting plate.
The Q-Tran Toroidal Transformer
is designed for dimming, quiet
operation, and higher lighting
performance.
Louvers to allow for 6-plane
surface mounting in any
position.
Secondary circuit
protection is provided
in every Q6 unit to
ensure complete
safety.
3
© Copyright Q-Tran, Inc. 2010
Dual tap recovers voltage
drop over longer runs and
dimmer losses for higher
lighting performance.
A Choke comes standard
in every unit (except 50 & 100W)
to reduce noise and in-rush
current.
Q6S Model - Power Supply Center (PSC)
50W - 300W
6S
Housing & Mounting - Small Size
18 Gauge welded steel measuring 8.63"L x 5.75"W x
3.1"H with 5 knockouts. Built-in mounting bracket is
designed for easy installation for both 6 planes of surface
mounting and suspension by two 1/4” threaded rods.
Standard finish is white powder coat.
Toroidal Transformer - Dual Tap (DT)
The Q6 Series Power Supply Center, utilizes two (2) primary taps
(12V, 13V or 24V, 26V). Loads may be connected to one (1) of
the primary taps up to the full watt rating of the Power Supply Center.
The advantage is that the PSC can be tapped to recover voltage drop
and produce between 85%-100% light output. See volatge drop
calculator on page 10.
Secondary Circuit
Protected by up to three magnetic circuit breakers.
Appropriate size to the feed load per N.E.C. Article 411 (not
to exceed 25 amps per load). All wiring by a certified
electrical contractor must be Class 1 compliant to N.E.C.
Chapter 3. Available in 5A, 10A, 12.5A, 15A, 20A, and 25A.
Toroidal Choke
3.100"
A Choke or "Debuzzing Coil" comes standard on every Q6S unit
(except 50W-100W) to reduce noise and in-rush current. A choke
is especially helpful when dimming. NOTE: Not required for 50W
& 100W transformers.
Mounting
Standard - 6 plane surface mount
Standard - Rod suspension (Two - 1/4” threaded rods)
Optional - Junction Box.
Model
Prim. V
1
1. Model
Q6S - 50DT
Q6S-100DT
Q6S-150DT
Q6S-300DT
2.
Max Lamp
Load Watts
50W
100W
150W
300W
/
PSC
Efficiency
3
No.
-
Rating (Watts)
54
108
163
324
230 (50/60Hz)
Transformer Secondary Voltage
Max PSC
Rating (VA)
W
W
W
W
6
+
Max Prim
Options
+
Amps@120V
58
115
173
345
0.5 A
1.0 A
1.4 A
2.9 A
Rated Volts
7
Max Prim A.
Amps@277V
0.2 A
0.4 A
0.62 A
1.2 A
6 - Plane Surface Mounting Design
1
2
3
WALL
4
5
6
CEILING
FLOOR
Max Volts
12 V
24 V
3
Three Secondary Circuit Breakers can be used
Secondary Breakers Amperage
6.
Amps
5
10
12.5
15
20
25
Choke
XX
CK-S
Max 12V Load
60W
120W
150W
180W
240W
300W
50W - 100W Choke - Not Required
150W - 300W Choke
Options
BK
JBP
Black Powder Coat Finish
Junction Box Mounting Plate
Ordering Example
5F78
13V
26V
Number of Secondary Breakers
5.
7.
5
Choke
277 (60Hz)
12 V
24V
4.
4 x
Max PSC
92%
92%
92%
92%
Brk Amp
Primary Voltage
120 (60Hz)
3.
2
-
Sec. V
5.750"
Max 24V Load
120W
240W
300W
360W
480W
600W
LOW VOLTAGE LIGHTING LUMINAIRE
POWER SUPPLY CENTER
SURFACE MOUNT ANY POSITION
SUITABLE FOR DAMP LOCATIONS
FOR SUPPLY CONNECTIONS USE
WIRE RATED FOR AT LEAST 90 C
SUITABLE FOR INDOOR USE ONLY
COMPLIES WITH N.E.C. ARTICLE 411
COMPLIES WITH UL STANDARD 2108
ISOLATION TOROIDAL TRANSFORMER
USE DIMMERS RATED FOR MAGNETIC
LOW VOLTAGE LOAD
50/60 CYCLE A.C. ONLY
MADE IN THE U.S.A.
Q6S - 300DT - 120/12 - 1x25 + CK-S
© Copyright Q-Tran, Inc. 2010
4
Q6M - Model Power Supply Center (PSC)
500W - 750W
6M
Housing & Mounting - Medium Size
11.000"
OP T I ONAL J B P
18 Gauge welded steel measuring 11"L x 7"W x 4.5"H
with 7 knockouts. Built-in mounting bracket is designed for
easy installation for both 6 planes of surface mounting and
suspension by two 3/8” threaded rods. Standard finish is
white powder coat.
Toroidal Transformer - Dual Tap (DT)
The Q6 Series Power Supply Center, utilizes two (2) primary taps
(12 V, 13V or 24V, 26V). Loads may be connected to one (1) of
the prima ry taps up to the full watt rating of the Power Supply Center.
The advantage is that the PSC can be tapped to recover voltage drop
and produce bet ween 85%-100% light output. See voltage drop
calculator on page 10.
Secondary Circuit
7.000"
Protected by up to five magnetic circuit breakers. Appropriate
size to the feed load per N.E.C. Article 411 (not to exceed 25
amps per load). All wiring by a certified electrical contractor
must be Class 1 compliant to N.E.C. Chapter 3 Available in
5A, 10A , 12.5A , 15A , 20A , and 25A .
4.500"
4.500"
Toroidal Choke
A Choke or "Debuzzing Coil" comes standard on every Q6M unit
to reduce noise and in-rush current. A choke is especially
helpful when dimming.
Mounting
Standar d - 6 plane surface mount
Standard - Rod suspension (Two - 3/8” threaded rods)
Optional - Junction Box .
Model
Prim. V
1
1. Model
Max Lamp
Load Watts
Q6M-500DT
Q6M-600DT
Q6M-750DT
500W
600W
750W
Q6MD-2x300DT
2.
600W
/
PSC
Efficiency
3
No.
-
Rating (Watts)
Max PSC
Max Prim
Rating (VA)
+
Amps@120V
7
Max Prim A.
Amps@277V
575
690
863
4.7 A
5.7 A
7.1 A
2.0 A
2.4 A
3.0 A
92%
648 W
690
5.8 A
2.4 A
6 - Plane Surface Mounting Design
1
2
3
WALL
4
5
6
CEILIN G
FLOOR
277 (60Hz)
Rated Volts
Max Volts
12 V
24 V
13V
26V
Number of Secondary Breakers
Secondary Breakers Amperage
Max 12V Load
60W
120W
150W
180W
240W
300W
Choke
CK-L
500W - 750W Choke
Options
BK
JBP
Black Powder Coat Finish
Junction Box Mounting Plate
Ordering Example
Q6M - 600DT - 120/12 - 2x25 + CK-L
5
© Copyright Q-Tran, Inc. 2010
5F78
LOW VOLTAGE LIGHTING
POWER SUPPLY CENTER
Five Secondary Circuit Breakers can be used
5
10
12.5
15
20
25
7.
6
+
Options
530 W
626 W
795 W
230 (50/60Hz)
Amps
6.
5
Choke
94%
94%
94%
Transformer Secondary Voltage
5
5.
4 x
Max PSC
12V
24V
4.
Brk Amp
Primary Voltage
120 (60Hz)
3.
2
-
Sec. V
7.000"
Max 24V Load
120W
240W
300W
360W
480W
600W
SURFACE MOUNT ANY POSITION
SUITABLE FOR DAMP LOCATIONS
FOR SUPPLY CONNECTIONS USE
WIRE RATED FOR AT LEAST 90 C
SUITABLE FOR INDOOR USE ONLY
COMPLIES WITH N.E.C. ARTICLE 411
COMPLIES WITH UL STANDARD 2108
ISOLATION TOROIDAL TRANSFORMER
USE DIMMERS RATED FOR MAGNETIC
LOW VOLTAGE LOAD
50/60 CYCLE A.C. ONLY
MADE IN THE U.S.A.
Q6L Model - Power Supply Center (PSC)
900W - 1800W
6L
Housing & Mounting - Large Size
15.000"
OP T I ONAL J B P
16 Gauge welded steel measuring 15"L x 10"W x 5.25"H
with 18 knockouts. Built-in mounting brac ket is designed
for easy installation for both 6 planes of surface mounting
and suspension by two 3/8” threaded rods. Standard
finish is white powder coat.
Toroidal Transformer - Dual Tap (DT)
The Q6 Series Power Supply Center, utilizes two (2) primary taps
(12 V, 13V or 24 V, 26V). Loads may be connected to one (1) of
the prima ry taps up to the full watt rating of the Power Supply Center.
The advantage is that the PSC can be tapped to recover voltage drop
and produce bet ween 85%-100% light output. See voltage drop
calculator on page 10.
Secondary Circuit
Protected by up to nine magnetic circuit breakers. Appropriate
size to the feed load per N.E.C. Article 411 (not to exceed 25
amps per load). All wiring by a certified electrical contractor
must be Class 1 compliant to N.E.C. Chapter 3 available in
5A, 10A , 12.5A , 15A , 20A , and 25A .
5.250"
10.000"
Toroidal Choke
5.250"
A Choke or "Debuzzing Coil" comes standard on every Q6L unit
to reduce noise and in- rush current. A choke is especially
helpful when dimming.
Mounting
Standar d - 6 plane surface mount
Standard - Rod suspension (Two - 3/8” threaded rods)
Optional - Junction Box .
Model
Prim. V
1
1. Model
Max Lamp
PSC
3
+
Max PSC
1035
1380
1725
2070
Rating (Watts)
900W
1200W
1500W
1800W
95%
95%
95%
96%
945 W
1260 W
1575 W
1863 W
Rating (VA)
6
Max Prim
Options
+
Amps@120V
8.4 A
11.2 A
14.0 A
16.0 A
7
Max Prim A.
Amps@277V
3.6
4.9
6.1
7.0
A
A
A
A
6 - Plane Surface Mounting Design
1
2
3
WALL
4
5
6
CEILIN G
FLOOR
Primary Voltage
230 (50/60Hz)
Transformer Secondary Voltage
277 (60Hz)
Rated Volts
Max Volts
12 V
24 V
12.5 V
25.0 V
Nine Secondary Circuit Breakers can be used
Secondary Breakers Amperage
Amps
Max 12V Load
5
10
12.5
15
20
25
6.
Choke
7.
Options
CK-XL
BK
JBP
Max 24V Load
60W
120W
150W
180W
240W
300W
900W - 1200W Choke
120W
240W
300W
360W
480W
600W
CK-XXL
Black Powder Coat Finish
Junction Box Mounting Plate
Ordering Example
5F78
LOW VOLTAGE LIGHTING LUMINAIRE
POWER SUPPLY CENTER
Number of Secondary Breakers
9
5.
5
Choke
Max PSC
12V
24V
4.
Brk Amp
4 x
-
Efficiency
120 (60Hz)
3.
/
No.
Load Watts
Q6L - 900DT
Q6L-1200DT
Q6L-1500DT
Q6L-1800DT
2.
2
-
Sec. V
10.000"
1500+ Choke
SURFACE MOUNT ANY POSITION
SUITABLE FOR DAMP LOCATIONS
FOR SUPPLY CONNECTIONS USE
WIRE RATED FOR AT LEAST 90 C
SUITABLE FOR INDOOR USE ONLY
COMPLIES WITH N.E.C. ARTICLE 411
COMPLIES WITH UL STANDARD 2108
ISOLATION TOROIDAL TRANSFORMER
USE DIMMERS RATED FOR MAGNETIC
LOW VOLTAGE LOAD
50/60 CYCLE A.C. ONLY
MADE IN THE U.S.A.
Q6L - 900DT - 120/12 - 3x25 + CK-XL
© Copyright Q-Tran, Inc. 2010
6
Q6 Ordering Guide
The Q6 Series can be ordered
using the guide and examples below. The specification key on the right defines the
ordering catagories and acronyms. A complete ordering form can be downloaded
at www.Q-Tran.com
SMALL HOUSING - includes choke (except 50W-100W) and 1 secondary breaker.
Model
Prim. V
Sec. V
No.
Brk Amp Choke
Options
Options 2
Specification Key
Q6S-50DT
-
/
-
x
+
+
+
PRIMARY VOLTAGE
Q6S-100DT
-
/
-
x
+
+
+
Q6S-150DT
-
/
-
x
+
+
+
120V
230V
277V
Q6S-300DT
-
/
-
x
+
+
+
SECONDARY VOLTAGE
MEDIUM HOUSING - includes cho ke and 2 secondary breakers
Model
Prim. V
Sec. V
No.
Brk Amp Choke
Options
Options 2
Q6M-500DT
-
/
-
x
+
+
+
Q6M-600DT
-
/
-
x
+
+
+
Q6M-750DT
-
/
-
x
+
+
+
Q6MD-2x300
-
/
-
x
+
+
+
NO. OF BREAKERS
S: 1-3
Prim. V
Sec. V
No.
Brk Amp Choke
Options
Options 2
Q6L-900DT
-
/
-
x
+
+
+
Q6L-1200DT
-
/
-
x
+
+
+
Q6L-1500DT
-
/
-
x
+
+
+
Q6L-1800DT
-
/
-
x
+
+
+
M: 1-5
L: 1-9
BREAKER AMPERAGE
LARGE HOUSING - includes choke and up to 4 secondary breakers
Model
12V
24V
5.5V
120V
Amps
5A
10A
12.5A
15A
20A
25A
12V
60W
120W
130W
180W
240W
300W
24V
120W
240W
300W
360W
480W
600W
CHOKE
CK-S
CK-L
CK-XL
CK-XXL
XX
150-300W Choke
450-750W Choke
900-1200W Choke
1500-1800W Choke
No Choke
OPTIONS
Q6 Model numbers and specifications can be found in this booklet. The
examples of the part number below reflects a Q6 Housing with a 1200W transformer
wired for 120V-12V with four 15A breakers and two 25A breakers, a choke and
standard white powder coat...
Q6L - 1200DT - 120/12 - 4x15 , 2x25 + CK - XL
For a complete ordering guide
7
© Copyright Q-Tran, Inc. 2010
please visit www.Q-Tran.com
WH
BK
PP
JBS
JBM
JBL
White (Standard)
Black Powder Coat
Prime Paint
Small Junction Box P late
Medium Junction Box P late
Large Junction Box P late
Q-Tran Ordering Guide Help
The Q6 Series ordering format is broken down into 8 steps. Model, Primary Voltage,
Secondary Voltage, Number of Breakers, Breaker Amperage, Choke, Options 1, and Options 2.
1
Model
2
3
4
5
6
Prim. V
Sec. V
No.
Brk Amp
Choke
-
/
-
x
+
7
7
Options
+
Options 2
+
This format should be used for
all Q-Tran power supply center
configurations.
Q-TRAN MODEL NUMBER
- Determine lamping wattage for each fixture
- Determine number of fixtures to be installed
- Multiply above to determine the total wattage
John Tremaine C.E.O.
1
Select proper model wattage to equal or
exceed total lamping wattage.
NOTE: Derating is not necessary.
Refer to product cut sheets for model information
PRIMARY VOLTAGE
2
Specify 120V, 230V or 277V
SECONDARY VOLTAGE
3
© Copyright Q-Tran, Inc.
Specify 12V, 24V, 5.5V or 120V
AMPS
NO. OF BREAKERS
4
Specify the number of secondary circuit breakers desired
BREAKER AMPERAGE
5
Specify the secondary circuit breaker amperage desired
If more than one amperage is required, repeat steps 4 and 5
CHOKE
6
Specify the correct choke to match the appropriate wattage
OPTIONS 1 & 2
7
MAX 12V
5
10
12.5
15
20
25
60W
120W
130W
180W
240W
300W
CHOKE
XX
CK-S
CK-L
CK-XL
CK-XXL
WH
BK
JPB
120W
240W
300W
360W
480W
600W
MODEL/WATTAGES
50W - 100W (No Choke)
150W - 300W
500W - 750W
900W - 1200W
1500W - 1800W
OPTION
Specify the additional features and/or benefits of Q-Tran
MAX 24V
DESCRIPTION
White (Standard)
Black Powder Coat
Junction Box Mounting Plate
NOTE:
For specialty wattages, voltages, amperages,
or hertz, please call the factory for information.
PHOTO
Q-TRAN, INC
155 Hill Street
Milford, CT 06460
Q-School
Q-Tran Trade Show Booth
© Copyright Q-Tran, Inc.
P. (203) 367-8777
F. (203) 367-8771
www.q-tran.com
© Copyright Q-Tran, Inc. 2010
8
Quieter... Brighter... Better...
Quieter ...
Many clients are very sensitive to noise and insist on a no noise guarantee. Many spaces today have ambient
levels as low as 25 dB. When dimmed, most standard lighting transformers are well above 40dB, so from the table
below, you can decide if Q-Tran is “quiet”. We think so.
Q-Tran had an acoustic noise test performed using a Q6S300
and a Q6M600 in Q-Tran’s state-of-the-art anachoic chamber.
Ambient noise in the chamber was 17.dB. With the
microphone only 3 feet away Q-Tran was...
Brighter ...
Model
Dimmer at 100% Dimmer at 70% Switch at 100%
Q6S-300
17.0 dB
18.5 dB
17.0 dB
Q6M-600
22.0 dB
22.9 dB
17.5 dB
Note: underdriving and overdriving lamps can reduce lamp life.
Standard Lighting Transformers do not operate Low Voltage at optimum light levels. The Power
Supply Centers (PSC), developed and manufactured by Q-Tran, are the first transformer systems specifically
designed for today’s low voltage lighting and its unique installation requirements. The heart of the PSC system is
a Torodial Multi-Volt Transformer. A Toroid is known for its small size, superior voltage regulation, quiet operation,
high efficiency, cool operating temperature and its ability to take the stress of dimming.
The Impact of Voltage Drop on Light Output
The Transformer’s Role In The Performance Of Low Voltage Lamps.
A 12V Lamp Operating at 10V = 50 % Light Output!
12V Low Voltage Down Lights
Key
Better ...
S = Switch
D = Dimmer at full bright
T = General purpose transformer
= Q-Tran Multi volt transformer
Multi-Volt toroidal transformers offer superior lamp performance by allowing the Q-Tran Power Supply Centers
to adapt to field conditions, ensuring that proper voltage is received at the lamp. Q-Tran transformers can operate
on a 12V system at 12 or 13 volts (24 or 26 volts for a 24 volt systems) which enables the system to compensate
for voltage drop from dimmer loss, load size, and resistance without increasing the wire size.
Dimmer - At full bright a dimmer has a 6V+ drop (120V in - 114 out) which significantly lowers light output.
Load Size - As determined by the NEC, the max load per run is 300W @ 12V and 600W @ 24V. The higher the
watts per run the greater the loss of light.
Wire Length - Larger wire gauge will help in keeping light loss to a minimum. See Voltage drop calculator.
Wire Gauge - The longer the wire run the greater the loss in light output. See voltage drop calculator
9
© Copyright Q-Tran, Inc. 2010
Quieter... Brighter... Better...
Example: The contractor is running a dimmed 300W load, 12V (25A) with 120 input. The remote Q-Tran transformer
is 15’ away from the load and 10 gauge wire will be used. Notice the four most common areas of voltage loss
referenced in the title bar below.
DIMMER
120V input
LOAD
114V output
COMMON
NEUTRAL
WIRE LENGTH
WIRE GAUGE
TAP 1
COM
TAP1
Secondary
TAP2
15’ run
300W load
Dimmer
120V input
69% LIGHT
POOR
10 gauge
10.6V
114V output
COMMON
NEUTRAL
TAP 2
COM
TAP1
Secondary
TAP2
300W load
15’ run
98% LIGHT
EXCELLENT
10 gauge
Dimmer
11.8V
Conclusion: With a simple field
adjustment, the contractor was able
to recover his / her voltage drop and
light output by switiching from Tap 1
to Tap 2.
QTM-DC - recessed or surface mount unit, up to 600W
QTM - recessed or surface mount unit, up to 750W
QTL- 5 tap recessed or surface mount unit, up to 1500W
Q6- 2 tap six plane surface mount unit, up to 1800W
Q-Vault - direct burial Q-Set Housing, up to 900W
MORE LIGHT !!!
Dimmer
Q-HEX
Q-TRIX
QO
Q-SET
Q-VAULT
Q6
WATTAGE & TRANSFORMER
Q-Tran transformers can support 50W-1800W
at 120V, 230V, or 277V input as well as a 12V,
24V, 5.5V or 120V output on most models.
Output wattage noted is total maximum lamp
wattage and de-rating is not necessary. Please
consult the ordering guide to determine the
specific wattages and voltages available on the
individual models within each product series.
50W
300W
500W
600W
750W
900W
On voltage Drop Calculator
OUTDOOR
20W
150W
*Note: Only use Tap 2 & 3
Q-Hex - 5 tap outdoor/landscape unit, up to 300W
}
10W
100W
www.Q-Tran.com
QO - outdoor/landscape unit, up to 960W
Q-Trix - direct burial Q-Hex Housing, up to 300W
INDOOR
WATTAGE
75W
See our Voltage Drop Calculator at:
QTL
QTM-DC
= 50%+
+
QQTM
TM
Q-Set - 5 tap direct burial unit, up to 900W
}
1200W
1500W
1800W
TOROIDS
SINGLE (1)
DUO (2)
QTM, QTL, QOM and Q-Set units are muti-volt to
compensate for voltage drop while the Q6
unit is dual tap which utilize a boost tap
to recover dimming losses.
TOROIDS
Many of Q-Tran’s units offer multiple toroids to
control multiple zones. SINGLE means the unit
contains one toroid, DUO means two toroids,
TRI means three and QUAD indicates a total of
four toroids per power supply center.
TRI (3)
QUAD (4)
MOUNTING
MOUNTING
Q-Tran’s premier PSC’s offer a wide variety of
mounting options. Q6 units can be mounted
on a wall surface, floor or ceiling in any direction
while QTM & QTL can be surface mounted or
recessed mounted into a 2x4 stud wall. QOM is
Q-Tran’s outdoor/landscape surface mount unit
while Q-Vault can be directly buried.
Surface
Recessed
Ceiling
Rod Suspension
Outdoor (Damp)
Outdoor (Wet)
Direct Burial
1. www.Q-Tran.com
2. Choose the Technical link
3. Voltage Drop Calculator
located at top right.
HOUSING
HOUSING COLOR
WHT Powder Coat
Most Q-Tran units are durable steel and come
in a standard white powder coat with a black
powder coat option. Q-Vault comes standard in a
black plastic enclosure suitable for direct burial.
A prime paint option is also available on select
models.
BLK Powder Coat
Stainless Steel
Aluminum
OPTIONS
Class 2
For a printed hard copy of our
Voltage Drop Calculator please
e-mail us at: catalog@q-tran.com
Please specify quantity.
OPTIONS
Pool & Spa
Cord & Plug
Q-Tran’s PSC’s offer a variety of options to
satisfy any installation demand.
Dimmer Plate
Secondary Taps
for more
information and complete specs, please see
the ordering guide or visit www.Q-Tran.com
© Copyright Q-Tran, Inc. 2010
10
Q6 Unit vs. a Standard EI Transformer...
FEATURE
quieter.
brighter.
better.
Q-TRAN, INC