Roadway
HighFocus
Above all,
maximizing
efficiencies
with light
Low-maintenance LED high mast solution
Elevate
your freedom
You already know that LED technologies can
significantly reduce energy usage and lightingrelated energy costs. But, did you know that the
right LED high mast luminaire can also be a
low-maintenance solution that reduces labor
and maintenance time, too? Introducing
Philips Lumec HighFocus LED high mast
luminaires – the high-performing,
low-maintenance high mast solution
that provides managers and work crews
with the freedom to focus on other tasks.
2
Philips Lumec
HighFocus LED high mast luminaires help to
reduce lighting-related energy costs compared
to HID technologies while meeting or exceeding
code requirements, and their long life, backed
by industry leading 10-year limited warranty
and Luminaire Useful Life rating, means that
maintenance time and related costs are also
reduced. Additionally, with among the highest
lumen output in the market today, as much as 50%
higher than other leading brands, you may be able
to significantly reduce the number of luminaires on
each pole without compromising on light quality
or a sense of security for those in the area.
HighFocus
Roadway
Intro
The savings
- money and
time - really
add up with
HighFocus
3
Your crews
spend less
time on
maintenance
and repair
Luminaire Useful Life
vs. Lumen maintenance
Not all high mast luminaires are built to the same
standards. Some manufacturers base their rated
life on a small portion of the overall luminaire –
only the LED lumen maintenance data. HighFocus
luminaires measure LED lumen maintenance as
well as LED life, driver life, on/off cycles, burn
4
Philips Lumec
hours, corrosion considerations, light engine PCB
substrate, solder joints and more. This provides
confidence that the entire HighFocus luminaire
will consistently perform today and far into the
future with extended lumen maintenance and
fewer trips needed for luminaire service.
HighFocus
Roadway
Savings
More time for
more savings
Whether you’re looking to
install a complete high mast
system, or replacing luminaires
in an existing high mast system,
HighFocus can help you to save
operational and maintenance
costs. With up to 103 LPW, and
31,223-97,389 delivered lumens,
it is possible to reduce the
overall number of luminaires
needed per high mast setup
when compared to traditional
HID technologies, thereby
further reducing energy-related
costs and initial project costs.
The long life of HighFocus,
backed by a 10-year limited
warranty, means that your
crews aren’t burdened by
endless and labor-intensive
re-lamping cycles.
All of this, and our exclusive
Luminaire Useful Life rating,
combine to provide payback
periods of 2.7 years, as shown
in the figure below. Contact us
directly to learn how connected
lighting options can help to
further optimize lighting-related
energy expenses, further
reduce payback periods, and
provide valuable insight into the
lighting infrastructure’s health
and operation.
58%
Annual energy
savings over HID 1
8,064
Metric tons of CO2
eliminated annually 2
This is an ROI example you can
achieve by retrofiting 4,000 HID
luminaires with 2,000 HighFocus
LED high mast luminaires.
2.7
1. B
ased on comparison between 1000W HPS luminaires (at 1150W) and HFL-276L1050NW-G1 (at 965W) with an energy rate of $0.1045/KWh.
National average energy rates and other assumptions apply. Contact Philips for more details and to help you determine your savings.
2. Conversion factors for CO2 calculations courtesy of the U.S. Environmental Protection Agency (U.S. EPA).
3. B
ased on national average energy rate and other assumptions. Your specific case may vary. Contact Philips for more details and to help
you determine your savings.
Payback
in years 3
5
Project a
guiding light
6
Philips Lumec
HighFocus
Roadway
Reliability
Motorists aren’t
inconvenienced by
frequent servicing
HighFocus benefits also extend to those using the space while helping you to project
a sustainable image. The long LED life means that drivers and others within the space
aren’t frequently inconvenienced by maintenance-related lane or area closures.
Consistent and uniform light levels, from HighFocus’s specially-designed discrete LED
optics mean that anyone can confidently navigate the well-lit area with ease.
7
Scalable solutions for
local challenges
HighFocus LED luminaires are scalable, so you can customize
your high mast solution to maximize your energy saving
benefits. They provide reliable and uniform LED illumination
ranging from 400 to 1000W HID replacement, while exceeding
the performance of traditional lighting technologies.
•Three lumen packages available providing
up to 97,389 lumens
•Precision optics direct more lighting to
the roadway
•Superior uniformity enhances visibility
•No uplight (U0 rating)
8
Philips Lumec
HighFocus
Roadway
With fewer luminaires to maintain,
you have even more time
Performance
Freeway
Luminaire Qty: 4
Distribution:
Type II (2)
Cloverleaf
Luminaire Qty: 5
Distribution:
Type V (5M)
Switching your HID high mast luminaires to HighFocus LED not
only saves energy and operating costs, it allows you to achieve
comparable photometric performance while cutting your
luminaire quantity in half.*
This means you have fewer luminaires to maintain, allowing you
to do more with less by simply switching to HighFocus.
Note: The luminaires and optical
distributions shown are examples.
Confirm which HighFocus is right for
you using a photometric layout of
your application.
up to
50%
Fewer luminaires*
than existing HID
*B
ased on photometric comparison of (8) 400W HPS Type 2 luminaires versus (4) HFL-184L1050NW-G1
and (10) 400W HPS Type 5 luminaires versus (5) HFL-184L1050NW-G1 HighFocus LED luminaires.
9
HighFocus
high mast luminaires
IP65 Rated compartment
Dimming driver
Surge protection
Electrical compartment is IP65 sealed with pre-installed
gasket to protect electrical components and terminal
block against dust and moisture, increasing reliability
and extending product life.
Dimming driver (0-10V) is standard,
enabling HighFocus to be combined with
additional controls, now or in the future
Standard SP1 and optional
SP2 surge suppressors
protect the luminaire
Finish
Black, Gray, White, Bronze
Mounting
IP66 Rated light engines
Die-cast housing
2-3/8" O.D. (2" NPS)
x 5-1/2" long tenon
Reliable light engines are IP66 sealed to
protect against dust and moisture so that
LED life is extended
Rugged, die-cast aluminum
housing for maximum durability
10 Philips Lumec
HighFocus
Twist-lock receptacles
Roadway
Optional 5-pin and 7-pin NEMA twist
lock receptacles available to facilitate
connected lighting solutions that
can quickly and easily be upgraded
in the future
Features
Rotatable optics
Entire optical assembly rotatable,
enabling alignment of asymmetric
optics parallel with roadway (as shown)
to optimize optical performance.
Bird guard
High mast system
Bird guard installed,
seals around tenon,
protects against birds
and similar intruders
Philips Lumec offers SkyMast raising and lowering device
SMLS-G2 to accompany your HighFocus LED High Mast
luminaires. Visit our eCatalog or contact your local sales
representative for more information.
LED Modules
2, 4, or 6 LED modules providing three different lumen packages
11
You can spend less
time managing your
high mast network
Above
and
beyond
Now, and in the future, a connected lighting system
can improve your ways of working, helping to
maximize energy and operational efficiencies.
This type of scalable system provides remote
monitoring, dimming and infrastructure status data
in real time from a central location without requiring
labor-intensive on-site assessments. Additionally,
each individual luminaire may be assessed for
granular management.
illumination
12 Philips Lumec
HighFocus
Roadway
Controls
Controls
City solutions
Advanced. Powerful. Extensive.
Widespread or multi-site lighting management with detailed asset management that can grow
along with your needs.
•AmpLight Group Cabinet Management
•HighFocus LED High Mast luminaires will be shipped controls ready when you select either 5-pin or 7-pin receptacle option; 0-10V dimming
driver is standard. Contact your local Sales Representative for more information and for help with putting together the entire system solution.
For more information
Visit us at www.philips.com/luminaires for more on Philips stand-alone and connected
outdoor lighting solutions, and select Controls Outdoor, or request our outdoor lighting
solutions brochure.
Take the next step
See how Philips Lumec HighFocus LED high mast luminaires can provide
a complete solution for your roadway lighting needs. Contact your local Philips
Sales Representative or visit www.philips.com/highfocus for more information
or to schedule a personalized demonstration.
13
Ordering information
Ordering guide
Luminaire
LED Module
example: HFL-276L1050NW-G1-2-HVU-DD-TLRD5-HS-GY3
Optical
System
Voltage
Driver and Dimming
Twist-Lock
Receptacle
Surge
Protection
UNV
120-277VAC
Standard:
Standard:
DD immable driver 0-10V
D
None (leave blank)
Optional:
Optional:
Optional:
AMPD 2
Amplight Dimming
TLRD5 3,4
Receptacle
for twist-lock
photocell or
shorting cap,
5-pin
SP2 5
20kV / 20kA
Surge Protector
Luminaire Options
Finish
HS
External house side shield
BK
Black finish
HIS
Internal house side shield,
snap-on, 1 per LED light
engine
BR
Bronze finish
HFL
HFL
HighFocus
92L1050NW-G1
or
184L1050NW-G1
or
276L1050NW-G1
2
Type II
3
Type III
4
Type IV
HVU
347-480VAC
5MType V
Medium
120 6120V
5WType V
Wide
208 6208V
1
240 6240V
277 277V
6
347 6347V
480 6480V
4
TLRD7 3,4
Receptacle
for twist-lock
photocell or
shorting cap,
7-pin
PH8 3,7
Twist-lock Photoelectric
Cell, UNIV (120-277VAC)
GY3
Gray finish
WH
White finish
PH8/347 3,7
Twist-lock Photoelectric
Cell, HVU (347VAC)
PH8/480 3,7
Twist-lock Photoelectric
Cell, HVU (480VAC)
PHXL 3,7
Twist-lock Photoelectric
Cell, extended life, UNIV
(120-277VAC)
PH9 3,7
Shorting cap
F1 6
Fusing, single (120, 277 or
347VAC)
F2 6
Fusing, double (208, 240
or 480VAC)
F3 6
Fusing, Canadian double
pull (208, 240 or 480VAC)
1.Please note these integrated features come standard with HighFocus luminaires.
2.Denotes programmable driver option. Not available with HVU (347-480VAC).
3.Use of photoelectric cell or shorting cap is required to ensure proper illumination.
4.HighFocus comes standard without a receptacle; to get a NEMA twist-lock receptacle,
select either TLRD5 5-pin or TLRD7 7-pin option.
5.When SP2 option is selected you will get SP2 instead of standard SP1.
6.Specific voltage (120, 208, 240, 277, 347 or 480) must be specified with fusing options
(F1, F2 or F3).
7.Includes TLRD5 unless TLRD7 is specified.
Prior to ordering, consult specification sheets on philips.com/luminaires for the most current information, notes, and exclusions.
Systems solutions
HighFocus LED High Mast luminaires will be shipped controls ready when you select either 5-pin or 7-pin receptacle
option; 0-10V dimming driver is standard. Contact your local Sales Representative for more information and for help
with putting together the entire system solution.
14 Philips Lumec
HighFocus
26-1/8''
663mm
23''
584mm
Roadway
Technical information
13-1/2''
343mm
Technical
21-1/4''
540mm
Dimensions
Bottom view
Side view
20 1/2''
521mm
26-1/8''
663mm
6-3/4''
172mm
Weight - 2 Module: 4
4 lbs
19.96 kg
23''
584mm
14-1/4''
362mm
5-1/8''
130mm
13-1/2''
343mm
21-1/4''
540mm
4 Module: 6
0 lbs
27.22 kg
6 Module: 7
5 lbs
34.02 kg
EPA - 1.89 sq. ft.
20 1/2''
521mm
6-3/4''
172mm
Luminaire Options
HIS
HIS HIS
HIS
14-1/4''
362mm
5-1/8''
130mm
HISHIS HS
HS HS
HS
PH8
PH8
HS
PH8
HS
PH8
Internal house side shield
External house side shield
F1
F2
F3
Single fuse
Double fuse
Canadian double pull fuse
PH9
PH9 PH9
PH8PH8
SPC
SPC SPCPH9
PH9
RC
RC
PHXL
PH9
Photocell
Photocell,
extended life
RC SPCSPC
RC RC
Shorting cap
Optical distributions
HighFocus offers many different optical distributions, providing the flexibility you need for all of your various roadway
lighting needs. Plus, all optical distributions have a U0 rating which means no uplight - all of the lighting is directed
downward on the roadway where it is needed.
Type
e II (2)
Type
II (2)
Type
II (2)
Type
II (2) II (2)
Type
Type
III (3)
Type
III (3)
Type
III (3)
Type
III (3)III (3)
Uplight
Uplight
Uplight
Uplight
aire
Luminaire
lumens Luminaire
lumens
Luminaire
lumens
Luminaire
lumens
lumens
37%
37%
37%
37%
28%
18%
28%
28%
28%
18%
18%
100
100
100
9%
100
9%
9%
90
90
90
90
90
80
80
80
80
80
60
30
Back
60
30
Back
60
30
0
Back
30
30
0Back
18%
3030
0
0
Front
37%
Uplight
Uplight
Uplight
Uplight
Luminaire
Luminaire
lumens Luminaire
lumens
Luminaire
lumens
Luminaire
lumens
lumens
38%
38%
38%
38%
28%
28%
18%
100
9%
60
60
Uplight
19%
19%
100
100
100
9%
100
9%
9%
90
90
90
90
90
90
90
90
90
90
80
80
80
80
80
80
80
80
80
80
30
Front0
60
30
60
60
6060
60
30
30
30
FrontBack Front
Back
Front
Back
60
30
0
Back
30
30
0Back
19%
3030
0
0
Front
Type III (3)
Type
Type
V (5M)
Type
V (5M)
Type
V (5M)
Type
V (5M)
V (5M)
38%
Uplight
Uplight
Uplight
Uplight
Luminaire
Luminaire
lumens Luminaire
lumens
Luminaire
lumens
Luminaire
lumens
lumens
35%
35%
35%
35%
28%
26%
19%
100
9%
60
60
Uplight
28%
100
60
Type II (2)
28%
100
100
1009%
19%
28%
Type
Type
V (4)
Type
V (4)
Type
V (4)
Type
V (4)V (4)
26%
26%
18%
18%
100
100
100
100
100
100
9%
100
9%
9%
90
90
90
90
90
90
90
90
90
80
8080
80
80
80
80
80
80
80
1009%
60
30
Front0
60
30
18%
26%
60
60
30
6060
60
30
30
FrontBack Front
Back Front
Back
60
30
0
Back
30
30
0Back
Type IV (4)
18%
3030
0
0
Front
35%
Uplight
Uplight
Uplight
Uplight
Luminaire
Luminaire
lumens Luminaire
lumens
Luminaire
lumens
Luminaire
lumens
lumens
35%
35%
35%
35%
26%
26%
18%
100
9%
60
60
Uplight
26%
18%
18%
100
100
100
100
9%
100
9%
9%
90
90
90
90
90
90
90
90
90
90
80
80
80
80
80
80
80
80
80
80
60
30
Front0
60
30
60
60
6060
60
30
30
30
FrontBack Front
Back
Front
Back
60
30
0
Back
30
30
0Back
18%
3030
0
0
Front
35%
Uplight
Uplight
Uplight
Uplight
Luminaire
Luminaire
lumens Luminaire
lumens
Luminaire
lumens
Luminaire
lumens
lumens
35%
35%
35%
35%
26%
26%
18%
100
9%
60
60
Uplight
26%
100
100
1009%
18%
26%
Type
Type
V (5W)
Type
V (5W)
Type
V (5W)
Type
V (5W)
V (5W)
26%
35%
26%
26%
18%
18%
100
100
100
100
100
100
100
9%
100
9%
9%
90
90
90
90
90
90
90
90
90
90
90
90
80
80
80
80
80
80
80
80
80
80
80
80
1009%
60
30
Front0
Type V Medium (5M)
60
30
18%
26%
Uplight
60
60
60 60
60
30
30
30
Front
Back Front
Back
Front
Back
60
30
0
Back
60
60
30
30
0Back
18%
1009%
60
3030
0
18%
100
9%
30
0
Front
Type V Wide (5W)
Note: The optical distributions shown are examples of the HFL-276L1050NW-G1. Consult HighFocus IES files for specific performance criteria.
15
Front0
100
60
30
Front
6
30
© 2016 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make
changes in specifications and/or to discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.
PLu-1508BR 04/16 philips.com/luminaires
Philips Lighting
North America Corporation
200 Franklin Square Drive
Somerset, NJ 08873
Tel. 855-486-2216
Philips Lighting Canada Ltd.
281 Hillmount Rd,
Markham, ON,
Canada L6C 2S3
Tel. 800-668-9008
Project:
Roadway
Location:
Cat.No:
Type:
HighFocus
Lamps: Qty:
Notes:
Philips Lumec HighFocus LED high mast luminaires provide an energy saving, lowmaintenance solution that provides managers and work crews with the freedom to
focus on other tasks. HighFocus LED features scalable lumen packages and offers
up to 97,389 lumens.
Ordering guide
Luminaire
LED Module
example: HFL-276L1050NW-G1-2-HVU-DD-TLRD5-HS-GY3
Optical
System
Voltage
Driver and Dimming
Twist-Lock
Receptacle
UNV
120-277VAC
Standard:
Standard:
DD immable driver 0-10V
D
None (leave blank)
Surge
Protection
Luminaire Options
Finish
HS
External house
side shield
BK
Black finish
HFL
HFL
HighFocus
92L1050NW-G1
or
184L1050NW-G1
or
276L1050NW-G1
2
Type II
3
Type III
4
Type IV
HVU
347-480VAC
5MType V
Medium
120 6120V
5WType V
Wide
208 6208V
1
4
Optional:
Optional:
Optional:
AMPD 2
Amplight Dimming
TLRD5 3,4
Receptacle
for twist-lock
photocell or
shorting cap,
5-pin
SP2 5
20kV / 20kA
Surge Protector
240 6240V
277 277V
6
347 6347V
480 6480V
TLRD7 3,4
Receptacle
for twist-lock
photocell or
shorting cap,
7-pin
HIS
Internal house side
shield, snap-on, 1 per
LED light engine
PH8 3,7
Twist-lock Photoelectric
Cell, UNIV (120-277VAC)
BR
Bronze finish
GY3
Gray finish
WH
White finish
PH8/347 3,7
Twist-lock Photoelectric
Cell, HVU (347VAC)
PH8/480 3,7
Twist-lock Photoelectric
Cell, HVU (480VAC)
PHXL 3,7
Twist-lock Photoelectric
Cell, extended life, UNIV
(120-277VAC)
PH9 3,7
Shorting cap
F1 6
Fusing, single (120, 277
or 347VAC)
F2 6
Fusing, double (208, 240
or 480VAC)
F3 6
Fusing, Canadian
double pull (208, 240 or
480VAC)
1.Please note these integrated features come standard with HighFocus luminaires.
2.Denotes programmable driver option. Not available with HVU (347-480VAC).
3.Use of photoelectric cell or shorting cap is required to ensure proper illumination.
4.HighFocus comes standard without a receptacle; to get a NEMA twist-lock
receptacle, select either TLRD5 5-pin or TLRD7 7-pin option.
HFL_Spec 04/16 page 1 of 5
5.When SP2 option is selected you will get SP2 instead of standard SP1.
6.Specific voltage (120, 208, 240, 277, 347 or 480) must be specified with fusing
options (F1, F2 or F3).
7.Includes TLRD5 unless TLRD7 is specified.
HFL HighFocus
High mast LED: 92, 184 and 276 LED
Systems Solutions
HighFocus LED high mast luminaires will be shipped controls ready when you select either 5-pin or 7-pin receptacle option; 0-10V dimming driver
is standard. Contact your local Sales Representative for more information and for help with putting together the entire system solution.
LED Wattage and Lumen Values
LED CRI = 70, CCT = 4000K nominal (3710K to 4260K)
System (LEDs + drivers) rated life = 100,000 hrs1
Typical
Delivered
Lumens
LED Module
Typical
System
Wattage (W)2
LED
Current
(mA)
Typical System Current (A) @
120V
HFL-92L-1050-NW-G1-2
32,361
320
1050
2.96
HFL-92L-1050-NW-G1-3
32,406
320
1050
2.96
HFL-92L-1050-NW-G1-4
30,987
320
1050
2.96
HFL-92L-1050-NW-G1-5W
31,223
320
1050
2.96
HFL-92L-1050-NW-G1-5M
32,804
320
1050
2.96
HFL-184L-1050-NW-G1-2
64,232
640
1050
5.93
HFL-184L-1050-NW-G1-3
64,295
640
1050
5.93
HFL-184L-1050-NW-G1-4
61,470
640
1050
5.93
HFL-184L-1050-NW-G1-5W
61,964
640
1050
5.93
HFL-184L-1050-NW-G1-5M
65,244
640
1050
5.93
HFL-276L-1050-NW-G1-2
95,707
965
1050
8.94
HFL-276L-1050-NW-G1-3
93,942
965
1050
8.94
HFL-276L-1050-NW-G1-4
90,397
965
1050
8.94
HFL-276L-1050-NW-G1-5W
93,482
965
1050
8.94
HFL-276L-1050-NW-G1-5M
97,389
965
1050
8.94
26-1/8''
663mm
1.L70 >100,000 hrs (at ambient temperature
= 25°C).
23''
584mm
2.System wattage or total luminaire
wattage includes the LED module and the LED driver.
208V
240V
277V
347V
480V
Efficacy
(Lm/W)
BUG Rating
1.71
1.71
1.71
1.71
1.71
3.42
3.42
3.42
3.42
3.42
5.15
5.15
5.15
5.15
5.15
1.48
1.48
1.48
1.48
1.48
2.96
2.96
2.96
2.96
2.96
4.47
4.47
4.47
4.47
4.47
1.28
1.28
1.28
1.28
1.28
2.57
2.57
2.57
2.57
2.57
3.87
3.87
3.87
3.87
3.87
1.02
1.02
1.02
1.02
1.02
2.05
2.05
2.05
2.05
2.05
3.09
3.09
3.09
3.09
3.09
0.74
0.74
0.74
0.74
0.74
1.48
1.48
1.48
1.48
1.48
2.23
2.23
2.23
2.23
2.23
101
101
97
98
103
100
100
96
97
102
99
97
94
97
101
B3-U0-G3
B3-U0-G4
B3-U0-G5
B5-U0-G4
B5-U0-G2
B5-U0-G5
B4-U0-G5
B4-U0-G5
B5-U0-G5
B5-U0-G2
B5-U0-G5
B5-U0-G5
B5-U0-G5
B5-U0-G5
B5-U0-G3
Note: D
ue to rapid and continuous advances in LED technology, LED luminaire data is subject to change without notice and at the discretion of Philips.
IES files with HS external house side shield and HIS internal house side shield options are also available – contact the factory.
13-1/2''
343mm
21-1/4''
540mm
Dimensions
Side View
Bottom View
20 1/2''
521mm
6-3/4''
172mm
5-1/8''
130mm
26-1/8''
663mm
Weight - 2 Module: 4
4 lbs
19.96 kg
23''
584mm
14-1/4''
362mm
13-1/2''
343mm
21-1/4''
540mm
4 Module: 6
0 lbs
27.22 kg
6 Module: 7
5 lbs
34.02 kg
EPA - 1.89 sq. ft.
20 1/2''
521mm
6-3/4''
172mm
5-1/8''
130mm
HFL_Spec 04/16 page 2 of 5
14-1/4''
362mm
HFL HighFocus
High mast LED: 92, 184 and 276 LED
LED Modules
2 modules
4 modules
6 modules
Predicted Lumen Depreciation Data
Predicted performance derived from LED manufacturer’s data and engineering design estimates, based on IESNA LM-80 methodology.
Actual experience may vary due to field application conditions.L70 is the predicted time when LED performance depreciates to 70% of
initial lumen output. Calculated per IESNA TM21-11. Published L70 hours limited to 6 times actual LED test hours.
Ambient Temperature °C
Driver mA
Calculated L70 Hours
L70 per TM-21
Lumen Maintenance % at 51,000 hrs
25°C
1050 mA
>100,000 hours
>51,000 hours
>90%
Specifications
Housing
Heat Sink
Driver
Made of a low copper die cast Aluminum
alloy (A360) for a high resistance to corrosion,
0.100" (2.5mm) minimum thickness. Fits on a 2
3/8" (60mm) O.D. (2" NPS) by 5 1/2" (140mm)
minimum long tenon. Comes with a zinc
plated clamp fixed by 4 zinc plated hexagonal
bolts 3/8-16 UNC for ease of installation.
Provides an easy step adjustment of +/ 3° tilt
in 3° increments. A single screw with sealing
washer, hinged, removable door opens upward
to provide access to electronic components
and to a terminal block. Door is secured to
prevent accidental dropping or disengagement.
Electrical compartment rated IP65 seal per
ANSI C136.25, provided with a pre-installed
gasket. Complete with a bird guard installed
which seals around tenon and protects against
birds and similar intruders. ANSI label to
identify wattage and source (included in box).
Anodized 6063-T5 Aluminum for a high
resistance to corrosion, designed to ensure high
efficacy and superior cooling by natural vertical
convection air flow pattern always close to
LEDs and driver optimizing their efficiency and
life. Product does not use any cooling device
with moving parts (only passive cooling). Wide
openings enable natural cleaning and removal
of dirt and debris.
Entire luminaire is rated for operation in
ambient temperature of -40°C / -40°F
up to +40°C / +104°F.
High power factor of 90% min. Electronic
driver, operating range 50/60 Hz. Auto
adjusting universal voltage input from 120
to 277 VAC or 347 to 480 VAC rated for both
application line to line or line to neutral,
Class I, THD of 20% max.
Light Engine
Composed of 4 main components:
Heat Sink / LED Module / Optical System / Driver
Electrical components are RoHS compliant,
IP66 sealed light engines. LEDs tested by
ISO 17025-2005 accredited lab in accordance
with IESNA LM-80 guidelines in compliance
with EPA ENERGY STAR, extrapolations in
accordance with IESNA TM-21. Metal core
board ensures greater heat transfer and
longer lifespan.
HFL_Spec 04/16 page 3 of 5
LED Module
Composed of high performance white LEDs.
Color temperature as per ANSI/NEMA bin
Neutral White, 4000 Kelvin nominal
(3985 +/- 275K or 3710K to 4260K), CRI 70 Min.
Optical System
Composed of high performance UV stabilized
optical grade polymer refractor lenses to
achieve desired distribution optimized to
get maximum spacing, target lumens and a
superior lighting uniformity. System is rated
IP66. Performance shall be tested per
LM-63, LM-79 and TM-15 (IESNA) certifying
its photometric performance. 0% uplight and
U0 per IESNA TM-15.
NOTE: Entire optical assembly rotatable,
enabling alignment of asymmetric optics
parallel with roadway to optimize optical
performance.
The current supplying the LEDs will be reduced
by the driver if the driver experiences internal
overheating as a protection to the LEDs and
the electrical components. Output is protected
from short circuits, voltage overload and
current overload. Automatic recovery after
correction. Standard built in driver surge
protection of 2.5kV (min).
Integrated Features
DD: Dimmable driver 0-10V.
SP1: Surge protector tested in accordance
with ANSI/IEEE C62.45 per ANSI/IEEE C62.41.2
Scenario I Category C High Exposure 10kV/10kA
waveforms for Line Ground, Line Neutral and
Neutral Ground, and in accordance with U.S.
DOE (Department of Energy) MSSLC (Municipal
Solid State Street Lighting Consortium) Model
Specification for LED Roadway Luminaires
Appendix D Electrical Immunity High Test Level
10kV / 10kA.
Please note that these integrated features
always come with HighFocus luminaires.
HFL HighFocus
High mast LED: 92, 184 and 276 LED
Specifications (continued)
Driver and Luminaire Options
NOTE: HighFocus LED high mast luminaires
will be shipped controls ready when you select
either 5-pin or 7-pin receptacle option; 0-10V
dimming driver is standard. Contact your local
Sales Representative for more information and
for help with putting together the entire system
solution.
AMPD: Driver pre-programmed for
compatibility with Amplight control
system.
AMPD not available with HVU (347480V)
Luminaire Useful Life
HS: External house side shield.
Wiring
PH9
TLRD5*: Receptacle with 5 pins enabling
dimming, can be used with a twist lock
control node or photoelectric cell or a
shorting cap.
TLRD7*: Receptacle with 7HIS
pins enabling
dimming additional functionality
(to be determined), can be used
with a twist lock control node or
photoelectric cell or a shorting cap.
HS
PH8
SPC
RC
The connection of the luminaire is done using
a terminal block connector 600V, 85A for
use with #2-#14 AWG wires from the primary
circuit, located inside the housing. Due to
the inrush current that occurs with electronic
drivers, recommend using a time delay or
slow blow fuse to avoid unnecessary and
unwanted fuse blowing that can occur with
fast acting fuses.
Please note: Additional hardware will be
required to utilize the additional 2 pins
on this receptacle.
HIS: Internal house
HIS side shield, 1 per LED
light engine.
PH8*: Twist-lock Photoelectric Cell, UNIV
PH8
SPC
(120-277AC). PH9
Refer to IES files for energy consumption and
delivered lumens for each option. Based on
ISTMT in situ thermal testing in accordance
with UL1598 and UL8750, Philips System
Reliability Tool, driver data and LED LM-80/
TM-21, expected to reach 100,000 + hours
with >L70 lumen maintenance @ 25°C.
Luminaire Useful Life accounts for LED lumen
maintenance AND all of these additional
factors including: LED life, driver life, PCB
substrate, solder joints, on/off cycles, burning
hours and corrosion.
F1: Fusing,
RC single (for 120, 277 or 347VAC).
Hardware
HS
PH8
PH9
All exposed screws shall be stainless for a high
resistance to corrosion. All seals and sealing
devices are made and/or lined with EPDM and/
or silicone and/or rubber.
Finish
PH8/347*: Twist-lock Photoelectric Cell,
HVU (347VAC).
PH8/480*: Twist-lock Photoelectric Cell,
HVU (480VAC).
PHXL*: Twist-lock Photoelectric Cell, extended
PH8life, UNIV (120-277VAC).
PH9
SPC
PH8
PH9*: Shorting cap.
PH9
SPC
RC
* Use of photoelectric cell or shorting cap is
required to ensure proper illumination.
HFL_Spec 04/16 page 4 of 5
F2: Fusing, double (for 208, 240 or 480VAC).
F3: Fusing, Canadian double pull
(for 208, 240 or 480VAC).
RC
Color in accordance with the AAMA 2603
standard. Application of polyester powder
coat paint (4 mils/100 microns) with ± 1 mils/24
microns of tolerance. The thermosetting resins
provides a discoloration resistant finish in
accordance with the ASTM D2244 standard,
as well as luster retention in keeping with the
ASTM D523 standard and humidity proof in
accordance with the ASTM D2247 standard.
The surface treatment achieves a minimum
of 2000 hours for salt spray resistant finish in
accordance with testing performed and per
ASTM B117 standard.
SPC
HFL HighFocus
High mast LED: 92, 184 and 276 LED
Specifications (continued)
LED products
manufacturing standard
The electronic components sensitive to
electrostatic discharge (ESD) such as light
emitting diodes (LEDs) are assembled in
compliance with IEC61340-5-1 and ANSI/
ESD S20.20 standards so as to eliminate ESD
events that could decrease the useful life of
the product.
Vibration Resistance
The HFL meets the ANSI C136.31, American
National Standard for Roadway Luminaire
Vibration specifications for Bridge/overpass
applications (Tested for 3G over 100,000
cycles by an independent lab).
Certifications and Compliance
High Mast System
cULus Listed for Canada and USA. Luminaire
meets DOE and MSSLC Model Specification for
LED Roadway Luminaires. HighFocus LED high
mast luminaires are DesignLights Consortium
qualified. Luminaire complies with or exceeds
the following ANSI C136 standards: .2, .3, .10, .15,
.18, .22, .25, .31, .37, .41.
Philips Lumec offers SkyMast raising and
lowering device SMLS-G2 to accompany
your HighFocus LED high mast luminaires.
Visit our eCatalog or contact your local sales
representative for more information.
Limited Warranty
10-year limited warranty.
See philips.com/warranties for
details and restrictions.
© 2016 Philips Lighting Holding B.V. All rights reserved.
Philips reserves the right to make changes in specifications
and/or to discontinue any product at any time without notice
or obligation and will not be liable for any consequences
resulting from the use of this publication.
philips.com/luminaires
HFL_Spec 04/16 page 5 of 5
Philips Lighting North America Corporation
200 Franklin Square Drive, Somerset, NJ 08873
Tel. 855-486-2216
Philips Lighting Canada Ltd.
281 Hillmount Rd, Markham, ON, Canada L6C 2S3
Tel. 800-668-9008