Low Sound Solutions

advertisement
AT, MT & ES Series – Super Low Sound Fan
The EVAPCO Super Low Sound Fan utilises an extremely wide chord
blade design for sound sensitive applications where the lowest sound
levels are desired. The fan is one-piece molded heavy duty FRP
construction utilising a forward swept blade design. The EVAPCO Super
Low Sound Fan is capable of reducing unit sound pressure levels 9
db(A) to 15 db(A), depending upon specific unit selection and
measurement location.
The EVAPCO Super Low Sound Fan is optional on ALL Induced Draft
Cooling Towers, ATWB, eco-ATWB, eco-ATWB-E, MTW and ESWB
Closed Circuit Coolers and ATC-E, cATC, eco-ATC and MTC-A
Evaporative Condensers 2.24 metres wide and larger.
AT, MT & ES Series – Low Sound Fan*
The EVAPCO Low Sound Fan utilises a wide chord blade design for
sound sensitive applications where low sound levels are desired. The
fan is a unique soft connect blade-to-hub design which eliminates
critical blade passing frequencies at any speed. The Low Sound Fan is
capable of reducing the unit sound pressure levels 4 db(A) to 7 db(A),
depending upon specific unit selection and measurement location.
The EVAPCO Low Sound Fan is optional on ALL Induced Draft Cooling
Towers, ATWB, cATWB, eco-ATWB, eco-ATWB-E, MTW and ESWB
Closed Circuit Coolers and ATC-E, cATC, eco-ATC and MTC-A
Evaporative Condensers.
*The Low Sound Fan will have a CTI Certified thermal performance
derate up to 3.5%. Consult the factory or EVAPCO’s evapSelect selection
software for actual thermal performance.
PM Series – Super Low Sound Fan
The Forced Draft Axial Fan Cooling Tower, Closed Circuit Cooler, and
Evaporative Condenser is now available with Super Low Sound Fans.
The one piece heavy duty fans built of FRP construction reduce sound
levels 10 db(A) to 13 db(A) on the fan side versus traditional PM towers, coolers and condensers.
The EVAPCO Super Low Sound Fan is standard on ALL PMTQ Cooling
Towers & PMWQ Closed Circuit Coolers, and optional on ALL PMC-E
Evaporative Condensers 3 metres wide and larger.
Induced Draft Low Sound Solutions
Fan Discharge Sound Attenuation*
Fan Discharge Sound Attenuation is a factory assembled
straight sided discharge hood designed to reduce overall
discharge sound levels 5 db(A) to 10 db(A), depending on
specific unit selection and measurement location. It is
constructed of G-235 galvanised steel as standard (stainless steel
construction also available) and includes acoustically lined
fiberglass walls and a low pressure drop baffling system. The
discharge attenuation option is supported entirely by the unit
and is shipped as an assembled section for easy field mounting.
Fan Discharge Sound Attenuation is optional on AT and cAT
Cooling Towers, ATWB, cATWB, eco-ATWB, eco-ATWB-E and
ESWB Closed Circuit Coolers and ATC-E, cATC and eco-ATC
Evaporative Condensers.
*Fan Discharge Sound Attenuation will have a CTI Certified
thermal performance derate up to 5%. Consult the factory or
EVAPCO’s evapSelect selection software for actual thermal
performance.
Water Silencers
Water Silencers are located in the falling water area of the
cold water basin. They are constructed of lightweight PVC
sections and can be easily removed for access to the basin
area. The water silencers reduce high frequency noise
associated with the falling water and are capable of reducing
overall sound levels 4 db(A) to 7 db(A) measured at 1.5 m:
from the side or end of the unit and 9 db(A) to 12 db(A)
when water is circulated with the fan(s) off.
Water Silencers are optional on ALL Induced Draft Cooling
Towers, ATWB, cATWB, eco-ATWB, eco-ATWB-E and MTW
Closed Circuit Coolers and ATC-E, cATC, eco-ATC and MTC-A
Evaporative Condensers 2.24 metres wide and larger.
Offset Sound Attenuation Walls
Offset Sound Attenuation Walls are EVAPCO’s newest
attenuation option for even greater levels of sound reduction
when used in combination with the Super Low Sound Fan and
Water Silencer options. The addition of Offset Sound
Attenuation Walls will typically reduce the 15 metre free field
sound level by an additional 3 db(A). The walls are
constructed of G-235 galvanised steel (stainless steel
construction also available) lined with acoustical padding on
the inside of the walls. This option requires external support
by others.
Offset Sound Attenuation Walls are optional on AT Cooling
Towers, ATWB, eco-ATWB and eco-ATWB-E Closed Circuit
Coolers and ATC-E & eco-ATC Evaporative Condensers with
Super Low Sound Fan and Water Silencer options selected.
Forced Draft Low Sound Solutions
†
Sound Attenuation Packages
LP/LR: The standard LP/LR design is the quietest, low profile centrifugal fan cooling tower, closed circuit
cooler and evaporative condenser in the industry. This is achieved by providing the first stage of inlet
sound attenuation as part of the standard design. The LP drive system, including the fan housing, electric
motor, belt, bearing, and drive is completely enclosed by a protective housing which covers the drive
system and also provides a significant level of sound reduction.
LS: The centrifugal fan design of the LS models operate at lower sound levels, which make these units
well suited for sound sensitive applications.
If the standard LS and LP/LR sound pressure levels are not low enough for certain applications, the
sound levels can be further reduced by adding various stages of sound attenuation as noted below.
Consult the factory for Factory Certified Sound Data for each option. Please refer to EVAPCO's
evapSelect selection software for correct model number designation and CTI Certified performance or
please contact your local EVAPCO's sales representative.
Discharge Attenuation*
Discharge Attenuation reduces overall discharge air sound levels. The discharge attenuator is a straight
sided hood with insulated baffles and a large access panel to allow entry to the drift eliminators and water
distribution system. If a higher discharge velocity is required with minimal sound attenuation, a tapered
discharge hood is available.
Fan Side Inlet Attenuation (LP/LR Only)
Fan Side Inlet Attenuation reduces sound radiated from the fan side air intakes and has an open side to
allow for air entry. Fan side inlet attenuation is included if full attenuation is selected for an LP/LR model.
* When both Discharge Attenuation and Inlet Attenuation are selected, this combination is referred to as Full Attenuation.
LSWE closed circuit cooler shown
with Full Sound Attenuation
† Mark owned by the Cooling Technology Institute
Printer: Trim off .625”
Inlet Attenuation*
Inlet Attenuation reduces sound radiated through the end and side air intakes. It consists of baffled panels
to change the path of the air entry and to capture the radiated noise thus reducing overall sound levels
generated. In addition, the external belt adjustment mechanism is extended through the inlet attenuator
to allow easy belt adjustment just within the access door. Solid bottom panels are included with this option
to force the inlet air through the attenuator.
Solutions for Sound
Sensitive Applications
S
Printer: Trim off .625”
ince its founding in 1976, EVAPCO,
Incorporated has become an industry leader
in the engineering and manufacturing of
quality heat transfer products around the world.
EVAPCO’s mission is to provide first class service and
quality products for the following markets:
䡲
䡲
䡲
䡲
䡲
Commercial HVAC
District Energy
Industrial Process
Industrial Refrigeration
Power
EVAPCO’s powerful combination of financial
strength and technical expertise has established the
company as a recognised manufacturer of marketleading products on a worldwide basis. EVAPCO is
also recognised for the superior technology of their
environmentally friendly product innovations in
sound reduction and water management.
EVAPCO is an employee owned company with a
strong emphasis on research & development and
modern manufacturing plants. EVAPCO has
earned a reputation for technological innovation
and superior product quality by featuring products that are designed to offer these operating
advantages:
䡲
䡲
䡲
䡲
EVAPCO’s induced draft counterflow product lines are now
available with an expanded line of equipment options to
reduce the overall sound generated from the side or top of
the unit. Each option provides various levels of sound
reduction, and most can be used in combination to provide
the lowest sound levels available in the industry.
Performance is CTI Certified on all induced draft cooling
towers and closed circuit coolers. Consult EVAPCO’s
evapSelect selection software for unit sound levels or a full
octave band data sheet. If a detailed analysis is required for
your application, please consult your EVAPCO sales
representative.
Higher System Efficiency
Environmentally Friendly
Lower Annual Operating Costs
Reliable, Simple Operation
and Maintenance
With an ongoing commitment to Research &
Development programs, EVAPCO provides the most
advanced products in the industry–Technology for
the Future, Available Today!
EVAPCO products are manufactured on five continents around the world and distributed
through hundreds of factory-authorised sales
representatives.
©2016 EVAPCO AUSTRALIA PTY LTD
EVAPCO’s forced draft counterflow product lines are
available with Super Low Sound Fan Technology. For the
first time, forced draft axial fan products are available
with sound levels comparable to a centrifugal fan at a
fraction of the power consumption. Consult EVAPCO’s
evapSelect selection software for unit sound levels or a
full octave band data sheet. If a detailed analysis is
required for your application, please consult your
EVAPCO sales representative.
EVAPCO Low Sound Solutions
Suggested Specifications
Thermal Performance
The cooling towers, inclusive of all accessories and sound reduction options, shall be CTI certified under standard
201RS (STD-201RS).
Sound Performance
Cooling tower sound performance shall be provided in pressure dB(A) measured 1.5 metres above the fan discharge during full speed fan operation with water running in accordance with CTI acceptance test code 128 (ATC128).
Super Low Sound Axial Propeller Fans (AT Series)
Units shall be provided with Super Low Sound Fans in order to assure a maximum sound pressure level not to
exceed _____ dB(A) measured 1.5m away from the fan discharge cylinder during full speed operation in accordance with CTI Standard ATC-128.
Fans shall be high efficiency axial propeller type with non-corrosive FRP hub and blade construction. The one-piece
molded heavy duty fan construction shall utilise a forward swept blade design for superior sound quality. Each fan
shall be statically balanced and installed in a closely fitted cowl with venturi air inlet for maximum fan efficiency.
The fan cowl shall be covered with a heavy gauge hot dip galvanised steel (or stainless steel) fan guard.
Low Sound Axial Propeller Fans*
Units shall be provided with Low Sound Fans in order to assure a maximum sound pressure level not to exceed
_____ dB(A) measured 1.5m above the fan discharge cylinder during full speed operation in accordance with CTI
Standard ATC-128.
Fans shall be high efficiency axial propeller type with aluminum wide chord blade construction. The Low Sound
Fan shall utilise a unique soft-connect blade-to-hub design that is compatible with Variable Speed Drives. Each fan
shall be statically balanced and installed in a closely fitted cowl with venturi air inlet for maximum fan efficiency.
The fan cowl shall be covered with a heavy gauge hot dip galvanised steel (or stainless steel) fan guard.
Fan Discharge Sound Attenuation
The unit shall be provided with a factory assembled straight sided discharge sound attenuation package designed
to reduce overall discharge sound levels. The discharge attenuator shall be supported entirely by the unit and
shipped as an assembled section for easy mounting in the field. It shall be constructed of G-235 galvanised steel
(or stainless steel) and include insulated walls and baffles acoustically lined with high density fiberglass. The discharge attenuator shall be covered by a heavy gauge hot dip galvanised steel (or stainless steel) fan guard to prevent debris from entering the attenuator.
Water Silencer*
The unit shall be provided with water silencers located in the falling water area of the cold water basin. The water
silencers shall be constructed of lightweight PVC in easily handled sections for ease of removal and access to the basin area.
* These options are available on Induced Draft only.
EVAPCO Australia Pty. Ltd - Regional Headquarters for Australia & New Zealand
EVAPCO Australia Pty Ltd • P.O. Box 436 • Riverstone, NSW 2765 Australia
PHONE: +61 9627 3322 • EMAIL: sales@evapco.com.au • WEBSITE: www.evapco.com.au
World Headquarters
Research/Development Center
EVAPCO, Inc.
North American Headquarters
P.O. Box 1300
Westminster, MD 21158 USA
Ph: 410-756-2600
Fax: 410-756-6450
E-mail: marketing@evapco.com
Bulletin 650H-AU
European Headquarters
EVAPCO Europe BVBA
European Headquarters
Industrieterrein Oost 4010
3700 Tongeren, Belgium
Ph: (32) 12-395029
Fax: (32) 12-238527
E-mail: evapco.europe@evapco.be
EVAPCO U.S.A. – http://www.evapco.com
EVAPCO EUROPE – http://www.evapcoeurope.com
EVAPCO ASIA – http://www.evapcoasia.com
EVAPCO AUSTRALIA – http://www.evapco.com.au
Asia/Pacific Headquarters
EVAPCO China
Asia/Pacific Headquarters
1159 Luoning Rd.
Baoshan Industrial Zone
Shanghai, P.R. China
Post Code: 200949
Ph: (86) 21-6687-7786
Fax: (86) 21-6687-7008
E-mail: marketing@evapcochina.com
Download