Outdoor-XUPs ~ 2100 watts, 230 vac, UPS with voltage regulation, 3000AHV/3000BHV Outdoor XUPs Series 230 vac outdoor uninterruptible power system Outdoor XUPs Outdoor XUPs model 3000AHV 3000 VA 2100 watts 230 vac 16 min @2100W 45 min @1050W -20° to +60°C; -40° to +60°C with optional battery heater 3000BHV 3000 VA 2100 watts 230 vac 45 min @2100W 2 hrs @1050W -20° to +60°C; -40° to +60°C with optional battery heater Pure sine wave Wide temperature batteries Outdoor UPS with voltage regulation TSi Power Outdoor XUPs-3000AHV/BHV units are constructed with extreme wide temperature batteries, and are housed in a weather protected IP44(NEMA-3R) enclosure. These offer lineinteractive automatic voltage regulation, over/ under-voltage protection, surge protection with heavy duty noise filtering, communications capability and optional extended battery backup. Key Outdoor XUPs benefits This rugged UPS design, with microprocessorcontrolled 20 kHz sine wave inverter and optional conformal coated boards, reduces the number of solid-state devices required for power conversion and is suitable for use in severe outdoor environments. Outdoor XUPs extreme/wide temperature batteries allow operation of the UPS system over an ambient temperature range of -20°to +60°C (- 4° to +140°F); - 40° to +60°C (-40° to +140°F) with optional battery heater. Built-in automatic voltage regulation enables a wide input voltage window within which power is delivered without having to drain or exercise the batteries, thereby ensuring long battery life. A fan exhausts hot air to protect batteries and electronics. OutdoorXUPs-3000AHV battery run-times are 16 minutes at 2100 watts load, and 45 minutes with a 1050 watts load; battery runtimes for the OutdoorXUPs-3000BHV are 45 minutes at 2100 watts load, and 2 hours with a 1050 watts load. How the Outdoor XUPs works TSi Power Corporation 1103 West Pierce Ave Antigo, WI 54409 USA 800 874 3160 (USA only) Phone +1 715 623 0636 Fax +1 715 623 2426 sales@tsipower.com www.tsipower.com Copyright © 2010 TSi Voltage regulation The Outdoor XUPs Series UPS provides automatic voltage regulation with surge protection and noise filtering, as well as overvoltage protection with a threshold of 280 vac, and undervoltage protection with a threshold of 190 vac. Upon a brownout, overvoltage, or loss of power, the XUPs will transfer to battery power in less than 4 milliseconds, enabling uninterrupted operation of computer, telecom, surveillance, signaling or other systems. LEDs provide visual assessment of UPS status. By unlatching, the front door swings open; inside the cabinet is an array of LED status indicators and a power on/off control switch. Note: shown with optional liquid-tight cable glands Typical applications This heavy duty outdoor UPS system is ideal for protection of WiFi/GSM/CDMA/satellite base stations, wireless communications/ perimeter surveillance and security/gate control systems, LED traffic light/roadway display systems and industrial remote terminal units (RTUs). Key Outdoor XUPs features • Cabinet can be pedestal(ground), pole, or wall mounted • Full weather outdoor protection IP44(NEMA-3R) metal cabinet • Pure sine wave output • Over/under-voltage protection • Remote power on/off (optional) • Wide temperature batteries • Heavy-duty surge protection and noise filtering • Automatic voltage regulation • Comprehensive array of status bargraphs for voltage, load and battery levels • Two year warranty on electronics, parts and labor; manufacturer’s warranty on batteries 1 2 Specifications OutdoorXUPs-3000AHV/BHV Outdoor XUPs Specification OutdoorXUPs-3000AHV OutdoorXUPs-3000BHV Electrical Capacity in VA (watts) UPS topology 3000VA (2100W) High efficiency line-interactive with 20 kHz PWM sine wave inverter Input Nominal voltage Input current Operating voltage 230 volts ac 12 amperes maximum @ 230 vac 190–280 vac without using batteries Operating frequency 47–63 Hz Output Nominal voltage Note: shown with optional liquid-tight cable glands Outdoor lineinteractive UPS with automatic voltage regulation and extreme/wide temperature batteries Voltage regulation 230 vac +/- 8% upon changes in line or load Crest ratio Output waveform Power efficiency Power on/off switch Transfer time Batteries Battery backup time Recharge time SNMP interface for UPS monitoring and automatic shutdown configuration (optional) Surge let-through voltages Status indicators TSi’s ongoing product improvement process makes specifications subject to change. Other companies product names herein are for identification purposes only, and may be trademarks of their respective companies. 230 volts ac Input/output connections 3:1 Pure sine wave, less than 3% THD with linear load 97%, under full load conditions On/off rocker style power switch <4 milliseconds 32 ampere hours, 48 vdc 64 ampere hours, 48 vdc Wide temperature sealed gel-cells -20° to +60°C (-4° to+140°F); -40° to +60°C (-40° to+140°F) with optional battery heater. 16 minutes @ 2100 watts load. 45 minutes @ 2100 watts load. 45 minutes @ 1050 watts load. 2 hours @ 1050 watts load. 8 hours to 90% capacity 16 hours to 90% capacity after full discharge. after full dischrge. Using an external SNMP adapter, the RS-232 signals (from the DB-9 female connector) from the UPS can be converted to 10M/100M fast Ethernet signals (and RJ-45 connection) for external UPS monitoring/ configuration capability using Telnet, web browsers, or NMS (for TCP/IP, UDP, SNMP, Telnet, SNTP, PPP, HTTP & SMTP protocols). Test pulse injection: Line-Neutral: Line-Ground: and Neutral-Ground. Combination Wave: L-N: 450V, L-G: 300 V, N-G: 300V 5 LED load level indicator: 0 to 100% of rated load. 5 LED battery charge level indicator from 0 to 100% of rated charge. 3 LED indicators for: in boost, buck or normal mode. 3 LED indicators for: inverter on/off, battery fault, and overload. 3 position terminal blocks provided for 3 x 2.5mm2 (14 AWG) connections via 12mm(1/2”) diameter holes. Physical Dimensions Weights Steel cabinet Mounting options 610 mm (24”) wide x 406 mm (16”) deep x 762 mm (30”) high 91 kg (200 lbs) 182 kg (400 lbs) Full weather IP44(NEMA-3R) outdoor design. Bolting or banding mountable to monopole via optional ‘H’ style bracket (steel mounting bands not included), pedestal (ground) with optional bottom mounted u-channel, or wall mountable via four wall mounting ‘feet’ which are included standard. Environmental TSi Power Corporation 1103 West Pierce Ave Antigo, WI 54409 USA 800 874 3160 (USA only) Phone +1 715 623 0636 Fax +1 715 623 2426 sales@tsipower.com www.tsipower.com Copyright © 2010 TSi Operating temperature, battery heater option and cooling method Moisture protection -20° to +60°C (-4° to+140°F) ambient air temperature. -40° to +60°C (-40° to+140°F) with optional battery heater. Thermostat controlled exhaust fan. Conformal coating of electronic boards for moisture resistance to protect against high humidity environments. Warranty Warranty 2 year limited warranty, parts & labor; manufacturer’s battery warranty. Outdoor XUPs Series 230 vac outdoor uninterruptible power system optional bandable or boltable monopole mounting brackets Outdoor XUPs Note: shown with optional liquid-tight cable glands OutdoorXUPs-3000AHV/BHV system architecture utility ac input ac circuit breaker hot earth ground chassis 190 – 280 volts ac neutral external battery (optional) heavy - duty ac surge protection, noise filter and overvoltage, undervoltage disconnect circuits + 10 % 0% - 10 % regulated XUPs output 230 vac +/-8% relay 1 logic relay 2 battery and charger dc hot neutral ac inverter chassis ground OutdoorXUPs-3000AHV/BHV at a glance Heavy-duty outdoor UPS with line-interactive automatic voltage regulation and extreme/wide temperature batteries TSi Power Corporation 1103 West Pierce Ave Antigo, WI 54409 USA 800 874 3160 (USA only) Phone +1 715 623 0636 Fax +1 715 623 2426 sales@tsipower.com www.tsipower.com Copyright © 2010 TSi • Wide ambient temperature range sealed gel-cell batteries: -20° to +60°C (-4° to +140°F); or -40° to +60°C (-40° to +140°F) with optional thermostat controlled battery heater • 230 vac +/-8% output from 190–280 vac input without going to batteries • 48 vdc battery bus • SNMP compatible (optional) • 16 minutes @ 2100 watts, or 45 minutes @ 1050 watts with the OutdoorXUPs-3000AHV • Less than 4ms transfer time • 45 minutes @ 2100 watts, or 2 hours @ 1050 watts with the OutdoorXUPs-3000BHV • Weather protected IP44/NEMA-3R painted metal cabinet • Microprocessor-controlled 20 kHz PWM sine wave inverter • Thermostat controlled fan is included 3 4 Outdoor XUPs Series OutdoorXUPs-3000AHV/BHV Outdoor XUPs Mounting on a concrete pad with U-channel Following is a drawing of a recommended pedestal/concrete pad mounted installation using the TSi Power aluminum U-channel mounting brackets. When ordered with these, the units will come with them already bolted to the bottom of the cabinet. There are four pre-drilled bolt holes that will then allow bolting of the unit to a concrete pad or other mounting surface, such as a Quazite® pad or Unistrut®. Outdoor XUPs pad mounted Note: shown with optional liquid-tight cable glands 610mm (24”) 406mm (16”) thermostat controlled hot air vent for exhaust fan (placement varies) 762mm (30”) door hinges IP44(NEMA-3R) metal cabinet door latch 102mm (4”) intake air vent underneath (or on side) XUPs output input/output holes (placement varies) ac input 64mm (2.5”) 6.3mm (.25”) thickness aluminum U-channel concrete pad 102mm (4”) above ground recommended TSi Power Corporation 1103 West Pierce Ave Antigo, WI 54409 USA 800 874 3160 (USA only) Phone +1 715 623 0636 Fax +1 715 623 2426 sales@tsipower.com www.tsipower.com Copyright © 2010 TSi Outdoor-XUPs-2100W-230-vac-UPS+voltage-regulation-3000-AHV-BHV-2010-06-06.pdf