Ubiquity Mobile Functionality Ubiquity Mobile Description Ubiquity Mobile is our custom application which is used with a PDA (Palm or Pocket PC) or laptop PC to locally access a networked TCS Basys Controls control system. The application is menu driven and allows the user to load, view, and edit various programming and monitoring parameters within the control system. Ubiquity Mobile can be used to access an entire network of controls or an individual controller, as needed. Neither the PC nor PDA integrates directly with the QD2040 Site Communications Center to use Ubiquity Mobile. Rather, Ubiquity Mobile resides on the PDA or PC which then connects via a cable to a QD1010 (RS232-to-RS485 converter). Then, a second cable connects the QD1010 to a single controller or network of controllers. However, if the PDA or PC has a web browser installed, it could connect directly to the QD2040 (in standalone mode) using a cross-over cable and utilize the QD2040’s internal Ubiquity browser-based software. Basic Functions of Ubiquity Mobile Include: • • • • • Programming of all controllers Monitoring controller inputs and outputs Modifying controller addresses Creating and modifying schedules Setting time and date on controllers (if applicable) TM 1000101000000101010101010101010101010100101010101010101010101 Mobile A TCS Basys Controls Solution TM mobile Ubiquity Mobile Mobile Quickstart Guide: A TCS Basys Controls Solution TM 1) Install Software Mobile A TCS Basys Controls Solution Mobile A TCS Basys Controls Solution There are two software applications which must be installed before using Ubiquity Mobile. Install Steps: Vary slightly based on the exact type/model of PDA. SuperWaba SuperWaba is an open-source software development platform for PDAs (Personal Digital Assistants) and Smartphones. It provides a rich set of user interface controls and functionalities plus multi-platform support (Palm OS, Windows CE, Pocket PC, and more). SuperWaba must be loaded and running on your PDA or laptop PC to use Ubiquity Mobile. Pocket PC & Other Windows CE Devices 1. Download/extract ubiquity_mobile_pc_ce.zip to your PC’s desktop. 2. Be sure your “hot sync” software is functioning & plug in your device. 3. Click/run _CEinstall-RunMe.bat (this installs SuperWaba). 4. Click/run _UBMobile_install_.bat (this installs Ubiquity For additional information on SuperWaba visit www.superwaba.com.br 5. Ubiquity Mobile is now installed and ready to run when started/activated. Ubiquity Mobile Ubiquity Mobile is our custom application which is used with a PDA or laptop PC to locally access a networked TCS Basys Controls control system. The application is menu driven and allows the user to load, view, and edit various programming and monitoring parameters within the control system. Ubiquity Mobile can be used to access an entire network of controls or an individual controller, as needed. Palm OS 1. Download/extract ubiquity_mobile_palm.zip to your PC’s desktop. 2. Be sure the “Hot Sync Manager” and “palmOne Quick Install” are functioning. 3. Double click each file to add it to the transfer list For additional information on Ubiquity Mobile visit www.tcsbasys.com Mobile and all the controller profiles SZxxxx.pdb and SLxxxx.pdb). (including SuperWaba.pdb, SuperWaba.prc, SWNatives.prc, UbMobile.pdb, UbMobile.prc,plus all SZxxxx.pdb and SLxxxx.pdb files). 4. Plug in your device and initiate the sync process. 5. Ubiquity Mobile is now installed and ready to run when started/activated. NOTE: For most connection configurations a seprate QD1010 is required between the PDA and the controller or controller network. TCS Basys Controls • 2800 Laura Lane Middleton, WI 53562 • PH: 800.288.9383 • FX: 608.836.9044 • www.tcsbasys.com Page: Ubiquity Mobile | Quickstart Guide 2) Initial Connection/Wiring Connect to entire control network through existing QD1010 STEP 1: Assemble PDA, adapters and cables (PI5000) STEP 2: Disconnect QD1010 from Gateway STEP 3: Connect PDA assembly to RS232 port on existing QD1010 - RS232 Cable - - - - - - - - - - - - - - RS232 - Serial to RS232 cable Adaptor RS485 - PDA to USB/Serial Adaptor GATEWAY QD1010 RS232 RS485 TO CONTROLLER NETWORK QD1010 TO CONTROLLER NETWORK Connect to entire control network through a single controller STEP 1: Connect PDA assembly to RS232 port of separate QD1010 STEP 2: Disconnect controller network from existing QD1010 RS232 -- -- -- -- -- -- -- -- -- - GATEWAY QD1010 QD1010 TO CONTROLLER NETWORK TO CONTROLLER NETWORK RS485 RS232 RS485 -- -- -- -- -- RS485 ----- RS232 RS485 STEP 3: Connect PDA/QD1010 assembly to RS485 port of any controller on controller network SL2108 QD1010 OR TO SINGLE CONTROLLER TO CONTROLLER NETWORK RS485 SZ1022 Connect to individual controller STEP 1: Connect PDA assembly to RS232 port of separate QD1010 STEP 2: Disconnect single controller from controller network RS485 RS232 RS485 -- -- -- -- STEP 3: Connect PDA/QD1010 assembly to RS485 port of single controller RS232 RS485 TO CONTROLLER NETWORK RS485 QD1010 SL2108 SL2108 OR TO SINGLE CONTROLLER RS485 -- -- -- -- QD1010 SZ1022 TO CONTROLLER NETWORK RS485 SZ1022 3) Software Startup/BasicInterface a. Tap/Click the UB Mobile icon. b. The startup screen will appear. c. The Ubiquity Mobile Main Window will appear. TCS Basys Controls • 2800 Laura Lane Middleton, WI 53562 • PH: 800.288.9383 • FX: 608.836.9044 • www.tcsbasys.com Page: Ubiquity Mobile | Quickstart Guide 4) Communication Screen You must first establish a comm. connection before attempting any other functions – tap/click the Communication button. b. Tap/Click the “Stop” button once all controllers have been found. c. The range (from x to y) can be changed to speed the autodetect process. Monitor Data a. Tap/Click the communication button. b. Be sure to match all settings shown. c. You must select “serial” from the drop-down even if it is showing already. ** a confirmation message will appear at the bottom of the screen – Port Serial opened at 9600 b/s 5) Main Menu Bar a. On Auto Detect screen, Tap/Click the desired controller. b. Use Menu Bar to go to Net/Mon>> Monitor Data option. c. Click “Read” to view that controller’s current monitoring data (live). d. To view another controller, use Menu Bar to go back to the Auto Detect screen and repeat these steps. 7) Program Screens The program screens allow you to view and modify program parameters including a controller’s address. The main menu bar is located at the top of each screen. It shows your correct location within Ubiquity Mobile. a. Tap/Click the Menu Bar. b. The Menu Bar expands. c. Tap/Click the desired location. 6) Monitor Screens Auto Detect The monitor screen allow you to locate and view live data from all controllers and monitors. a. Tap/Click the “Start” button to begin autodetecting. Load Controller a. Enter the address of the desired controller. b. Tap/Click the “Read Id” button. ** a confirmation message will appear at the bottom of the screen – Addr # XXXX #=address number, XXXX= prod model number c. Select the controller type from the drop-down that matches the model number shown at the bottom of the screen after “Read Id”. d. Set the changes as temporary or permanent. • temporary – Used for testing purposes. Once the test changes are no longer needed YOU MUST restore the original settings before selecting another controller (Menu Bar >> Program >> RD/Wr >> Restore All). TCS Basys Controls • 2800 Laura Lane Middleton, WI 53562 • PH: 800.288.9383 • FX: 608.836.9044 • www.tcsbasys.com Page: Ubiquity Mobile | Quickstart Guide • permanent – Any changes made to the controller will remain AND will be sent to Ubiquity once the controller network is reconnected. This option allows you to jump to another controller after writing changes (DOES Program Submenu: Browse NOT require “restore all”). e. Tap/Click the “Load Controller” button. ** a confirmation message will appear at the bottom of the screen – Load Succeeded f. Tap/Click the “Read Id” button again. Change Controller’s Address a. Enter the current address of controller. b. Tap/Click the “Apply Addr.” button to select the contoller. c. Tap/Click the “Change Cont. Addr” button. d. Change the address to the desired value in the pop up window . e. Tap/Click the “Ok” button. Programming Process When programming always follow these steps. a. Read values for current page (this MUST be done before writing any changes). b. Make any desired changes (highlight and then change). c. Write values for current page. d. Read values to confirm change has been made. e. Go to next or prev screen repeat steps above. - read button - write button - previous button - next button • Next – Goes to the next page for current controller. • Previous – Goes to the previous page for current controller. • First – Goes to the first page for current controller. • Load Cont. – Goes to the main program screen. • Goto Page – Allows you to jump to any previously. viewed page for current controller. • Page Info – Opens window showing page# and description. Program Submenu: RD/Wr • Read Page – Loads the current values for all parameters shown on the page. • Write Point – Writes a single value (the last modified parameter) to the controller. • Write Page – Writes all values shown on the page to the controller. • Disp. Org. Page – Displays original values for current page. • Rest&Wr Page – Display original values for current page and writes all values shown to the controller. • Restore All – Restores ALL parameters on all pages to their original values and writes ALL values to the controller. Change Controllers Use the Menu Bar to go to the Main Program screen to select a different controller to program. a. Tap/Click the Menu Bar. b. Tap/Click Browse option. c. Tap/Click Load Cont (takes you to the Load Controller screen) option. d. Select a new controller and repeat programming steps. TCS Basys Controls • 2800 Laura Lane Middleton, WI 53562 • PH: 800.288.9383 • FX: 608.836.9044 • www.tcsbasys.com