Quick-fitting Type Mechanical Valve Mechanical Valve Features This push-type valve turns on and off the input of air pressure. The operating force is not affected by strength of pressure owing to the spool valve mechanism. The valve has three ports to exhaust the residual pressure on the output side (equipment) when closed and two ports that have no exhaust function. spool (nickel-plated brass) Construction Resin body (Polybutylene telephthalate) Insert ring (nickel-plated brass) Push pin (polyacetal) Flat O-ring (nitrile rubber) Tube Guide (nickel-plated brass) Elastic sleeve (nitrile rubber) Seal ring (nickel-plated brass) Tube Release ring (polyacetal) Spring holder (nickel-plated brass) Specification Fluid admitted Service pressure range Working vacuum Lubrication Model Designation (Example) MVM 6 (1) (2) (1)Type MVM : Micro Switch Type MVP : Panel Mount Type MVU : Air Switch MVF : Foot Switch (2)Tube Dia. Code Size 4 φ4mm 6 φ6mm 3 (3) Air 0~100psi 0~0.7MPa 32~140°F 0~60°C ISO VG32 (Turbine oil class 1) A (4) R (5) J (6) (7) (5)Operation system No code : pin R : Roller lever *Pin only in MVU. 1/8 5/32 φ1/8in. φ5/32in. (6)Exhaust Mode (only 3-way valves) No code : Open to atmosphere via silencer J : Concertrated exhaust via fitting (7)Hexagon flat-to-flat specification (3)No. of ports Code No. of port Lock claw (stainless steel) Spring (piano wire) *Black in normal-close type, ivory in normal-open type. 2 2 U: Hexagon flat-to-flat inch spec. (NPT) No code: Hexagon flat-to-flat mm spec. 3 3 (4)Standby position No code : Nomally closed (Release ring is black) A : Normally open (Release ring is ivory) *Only normally close type in MVP and MVU. Application example spool P port P port A port A port Exhaust port Exhaust port In case of Three-Way, Normally Open type, the compressed air entered from P port flows to A port. While the spool is pushed down, the air inlet is blocked and the residual pressurized air is released from the exhaust port (open to air type or concentrated exhaust type). *Three-Way, Normally Closed type works contrary to Normally Open type. 292 MVM Tube dia. Stroke Dimensions for Pin Type Operating Stroke S2 1.0 1.6 Over Stroke S3 0.4 0.4 Recommended Stroke S4 2 3.2 S3 S5 S4 S2 S1 φ4 φ6 Pre-Stroke S1 1.0 1.6 unit:mm Max. Stroke S5 2.4 3.6 MVM Model Microswitch Pin Type MVM 4 MVM 4 MVM 6 MVM 6 2-φD B2 A A B2 L1 L2 φP C J 8 4 23.5 21 33 17 7 8 11 6 30.5 27 33.5 22 6.5 10.5 12 unit:mm Mass Eff. a. F (g) (mm2) 10 10.5 3 10.5 10.5 15.5 12.5 7 2-φP J L1 B1 F L2 2-C B1 Tube dia. φD max min φ10 14.5 20.5 11 2-φ3.3 MVM Model Microswitch Pin Type (Concentrated Exhaust) 3-C E 3-φP B2 L1 L2 φP C J1 J2 E 4 26.5 24 33 17 7 8 11 8 8.5 15 10.5 11 6 34.5 31 33.5 22 F 6.5 10.5 12 10.5 11.5 16.5 15.5 14.5 15 3 7 L1 J2 J1 B1 F L2 3-φD B2 20.5 14.5 MVM 43-J MVM 43A-J MVM 63-J MVM 63A-J unit:mm Mass Eff. a. (g) (mm2) B1 Tube dia. φD max min 11 2-φ3.3 MVM Tube dia. φ4 φ6 Operating Stroke S2 1.7 2.5 Over Stroke S3 0.4 0.4 Recommended Stroke S4 3.2 4.5 unit:mm Max. Stroke S5 3.6 4.9 S3 S5 S1 S2 S4 Stroke Dimensions for Roller Type Pre-Stroke S1 1.5 2.0 294 MVM Model Microswitch Roller Type B2 φ9 B2 L1 34.5 30.5 33 17 4 6 42 37 L2 max min 33.5 22 φP C J 8 18 14.5 8 11 19.5 15 10.5 12 unit:mm Mass Eff. a. (g) (mm2) F 10.5 12.5 10.5 15.5 15 3 7 2-φP J F L1 B1 2-φD 7 2-C L2 MVM 4 -R MVM 4 A-R MVM 6 -R MVM 6 A-R B1 Tube dia. φD max min φ10 14.5 20.5 11 2-φ3.3 MVM Model Microswitch Roller Type (Concentrated Exhaust) B2 20.5 14.5 φ9 MVM 43-RJ MVM 43A-RJ MVM 63-RJ MVM 63A-RJ 6 37.5 33.5 33 46 17 18 14.5 φP C J 8 11 8 unit:mm Mass Eff. a. E F (g) (mm2) 13 15 10.5 3 13.5 41 33.5 22 19.5 15 10.5 12 10.5 16.5 15.5 17 7 J2 J1 L1 L2 B1 3-φP F 3-C E 11 2-φ3.3 MVP Tube dia. Stroke Dimensions for Pin Type S5 S4 S2 S1 S3 MVP Panel Mount Type Pin Type B L 12 MVP 42 MVP 43 MVP 62 3-H14 MVP 63 2-C E M10×0.75 2-φD φ4 φ6 Model φ9 6 3 9.5 295 4 B2 L2 L1 max min 3-φD 7 B1 Tube dia. φD max min 2-φP Pre-Stroke S1 1.8 1.8 Tube dia. φD 4 6 Operating Stroke S2 1.8 1.8 B max 49.5 49 49.5 49 min 46 45.5 46 45.5 Over Stroke S3 0.4 0.4 L 33 32.5 33 32.5 Recommended Stroke S4 3.6 3.6 φP C E 8 11 18 10.5 12 18.5 unit:mm Max. Stroke S5 4 4 unit:mm Mass Eff. a. (g) (mm2) 31 30 32 31 3 5 MVP Model Panel Mount Pin Type (Concentrated Exhaust) B 6 41.5 3 9.5 2-12 MVP 43-J MVP 63-J Tube dia. φD 4 6 φP C E Mass (g) unit:mm Eff. a. (mm2) 8 10.5 11 12 18 18.5 33 35 3 5 B max 57 57 min 53.5 53.5 3-C E φ9 3-H14 M10×0.75 3-φD 3-φP MVP Tube dia. Stroke Dimensions for Roller Type φ4 φ6 S5 S4 S3 S2 2.5 MVP Model Panel Mount Roller Type MVP 42-R MVP 43-R MVP 62-R MVP 63-R B 19.5 9.5 L 12 6 2-φD Panel Mount Roller Type (Concentrated Exhaust) 41.5 9.5 2-12 Tube dia. φD 4 6 B max 56.5 57 56.5 57 min 53 53.5 53 53.5 L 33 32.5 33 32.5 φP C E 8 11 18 10.5 12 18.5 unit:mm Mass Eff. a. (g) (mm2) 34.5 33.5 35.5 34.5 3 5 Model Tube dia. φD MVP 43-RJ MVP 63-RJ 4 6 B max 66 66 min 62.5 62.5 φP C E Mass (g) unit:mm Eff. a. (mm2) 8 10.5 11 12 18 18.5 36.5 38 3 5 3-H14 3-C E 19.5 B 6 3-φD unit:mm Max. Stroke S5 4.3 4.3 2-φP MVP 2.5 Recommended Stroke S4 3.9 3.9 2-C E 2.5 M10×0.75 Over Stroke S3 0.4 0.4 3-H14 M10×0.75 φ9 Operating Stroke S2 2.1 2.1 Stroke Dimensions were measured for the product mounted on 2.5-mm plate. Dimensions vary when the thickness of the plate changes. S1 φ9 Pre-Stroke S1 1.8 1.8 3-φP 296 MVU Model Air Switch 2-φ3.4 MVU 42 MVU 43 MVU 62 MVU 63 2.5 φ8 2-13 35.5 8 Tube dia. φD B C 4 29 11 6 31.5 12 Mass (g) 22.5 24 22.5 24 unit:mm Eff. a. (mm2) 3 5 Main body is Ivory color. Release ring is black. 22 10 22 B 2-φD 2-C (stroke) MVF Model Foot Switch MVF 4 MVF 6 80 11.5 4-φ5.5 96 297 6 52 14.5 6 50 14.5 120 MVF 4 MVF 6 Tube dia. φD Mass (g) unit:mm Eff. a. (mm2) 4 6 172.5 174.5 3 7 uses MVM 4 uses MVM 6 or MVM 4 or MVM 6 A. A. ! Detailed Safely Instruction Before using the PISCO device, be sure to read the "Safety Instructions","Common Safety Instructions for Products Listed in This Manual" on page 23~24 and "Common Safety Instructions for Change Series Valves" on page 279. ! Warning 1. Do not allow any load beyond the limit stroke to bear on the push pin or roller by maschine operation. Otherwise damage to the body may result. 2. Do not use the valve with cam and dog whose operation involves steep leading and trailing edges. Impacts may inflict damage to the device body. 3. Do not carry out the air switch or foot switch type of operation by a machine. Such an operation may damage the device body. 4. In applications that require high level of reliability, make certain that the mechanical valve operates properly at start-up. 5. Do not subject the product with a rotary resin body to forcible swinging or rotation. Otherwise the body may suffer damage or develop leakage. 6. Do not use the valve in locations where it can be exposed to water drops, oil drops, dust, etc. The valve is neither drip-proof nor dustproof, so that malfunction may result. 1. 2. 3. 4. 293 ! Caution Consult PISCO about applications involving frequent operations. Confirm the number of ports and the conduction system by checking the marking on the body. With the microswitch or the panel mounting type, the effective sectional area may change with the stroke. Insufficient stroke may cause low flow rate. With the air switch or the foot switch type, push the button or the top lid of the case completely until it stops. Failure to do so may result in poor conduction or low flow rate due to faulty switching.