Presentation, general characteristics Limit switches 3 b XCK J Osiswitch® 3 Classic Metal, type XCK J Conforming to CENELEC EN 50041 v With head for linear movement (plunger) 561647 561646 fixed body with 1 cable entry Page 37633/2 561650 561649 561648 v With head for rotary movement (lever) or multi-directional Page 37633/2 b XCK J v With head for linear movement (plunger) 561652 561651 plug-in body with 1 cable entry Page 37636/2 561655 561654 561653 v With head for rotary movement (lever) Page 37636/2 Environment characteristics Conforming to standards Product certifications Protective treatment Ambient air temperature Vibration resistance Shock resistance Electric shock protection Degree of protection Repeat accuracy Cable entry or integral connector Materials 32400-EN_Ver6.3.fm/2 Products Machine assemblies Version Operation Storage Conforming to IEC 60068-2-6 Conforming to IEC 60068-2-27 Depending on model IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14 IEC 60204-1, EN 60204-1 UL, CSA Standard “TC”, special "TH" - 25…+ 70 °C, special sub-assemblies available for extreme temperatures (-40 °C or +120 °C) - 40…+ 70 °C 25 gn (10…500 Hz) 50 gn (11 ms) Class I conforming to IEC 61140 and NF C 20-030 IP 66 conforming to IEC 60529; IK 07 conforming to EN 50 102 0.01 mm on the tripping points, with 1 million operating cycles for head with end plunger Tapped entry for n° 13 cable gland, or tapped ISO M20 x 1.5 or 1/2" NPT, or M12 connector Bodies and heads in zamak Schneider Electric General characteristics Limit switches (continued) Osiswitch® 3 3 Classic Metal, type XCK J Conforming to CENELEC EN 50041 Contact block characteristics XE2p P a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A c DC-13; Q300 (Ue = 250 V, Ie = 0.27 A), conforming to IEC 60947-5-1 appendix A, EN 60947-5-1 a AC-15; B300 (Ue = 240 V, Ie = 1.5 A); Ithe = 6 A c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 appendix A, EN 60947-5-1 Ui = 500 V degree of pollution 3 conforming to IEC 60947-1 Ui = 300 V conforming to UL 508, CSA C22-2 n° 14 Ui = 400 V degree of pollution 3 conforming to IEC 60947-1 Ui = 300 V conforming to UL 508, CSA C22-2 n° 14 XE3p P XE2p P XE3p P XE2p P XE3p P Rated impulse withstand voltage U imp = 6 kV conforming to IEC 60947-1, IEC 60664 U imp = 4 kV conforming to IEC 60947-1, IEC 60664 Positive operation (depending on model) Resistance across terminals Short-circuit protection N/C contacts with positive opening operation conforming to IEC 60947-5-1 Appendix K, EN 60947-5-1 y 25 mW conforming to IEC 60255-7 category 3 10 A cartridge fuse type gG (gl) 6 A cartridge fuse type gG (gl) XE2p P XE3p P XE2S P21p1 XE2N P21p1 XCK J plug-in and XES P20p1 XE3N P and XE3S P Cabling (screw clamp terminals) Clamping capacity, min: 1 x 0.34 mm2, max: 2 x 1.5 mm2 Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 2.5 mm2 Clamping capacity, min: 1 x 0.75 mm2, max: 2 x 1.5 mm2 Clamping capacity, min: 1 x 0.34 mm2, max: 1 x 1 mm2 or 2 x 0.75 mm2 XE2S P21p1 and XE3S P: 0.01 m/minute XE2N P21p1 and XE3N P: 6 m/minute b Conforming to IEC 60947-5-1 Appendix C b Utilisation categories AC-15 and DC-13 b Maximum operating rate: 3600 operating cycles/hour b Load factor: 0.5 XE2N P21p1 XCK J plug-in, XES P20p1 Minimum actuation speed Electrical durability Millions of operating cycles XE2S P21p1, XE2S P2141 a.c. supply a 50/60 Hz o inductive circuit 5 Ithe 1 110 V 0,5 24 V 230/400 V 48 V 0,1 0,5 230 V 2 12/24/48 V 110 V 1 0,5 5 4 3 Ithe 12/24 V 2 1 230 V 48 V 0,5 0,2 0,1 0,5 10 3 4 5 Current in A Ithe 5 1 0,5 110 V 230/400 V 24 V Millions of operating cycles a.c. supply a 50/60 Hz o inductive circuit 2 Ithe 1 2 3 4 5 10 Current in A 0,1 0,5 110 V 1 2 10 3 4 5 Current in A Power broken in W for 5 million operating Power broken in W for 5 million operating Power broken in W for 5 million operating cycles. cycles. cycles. Voltage V 24 48 120 Voltage V 24 48 120 Voltage V 24 48 120 o W 10 7 4 o W 13 9 7 o W 10 7 4 For XE2S Pp151 on a or c, N/C and N/O contacts simultaneously loaded to the values shown with reverse polarity. XE3N Ppppp XE3S Ppppp Millions of operating cycles d.c. supply c 1 5 4 3 Millions of operating cycles Rated insulation voltage Millions of operating cycles Rated operational characteristics Ithe 5 4 3 2 230 V 1 12/24/48 V 110 V 0,5 0,2 48 V 0,1 0,5 d.c. supply c Schneider Electric 1 2 10 3 4 5 Current in A Power broken in W for 5 million operating cycles. Voltage V 24 48 120 o W 3 2 1 0,1 0,5 1 2 3 4 5 10 Current in A Power broken in W for 5 million operating cycles. Voltage V 24 48 120 o W 4 3 2 32400-EN_Ver6.3.fm/3 Limit switches References, characteristics Type of head Type of operator Osiswitch® 3 3 Classic Metal, conforming to CENELEC EN 50041, type XCK J Complete switches, fixed body ISO M20 x 1.5 cable entry Plunger (fixing by the body) Rotary (fixing by the body) (switches supplied for actuation from left AND right) Form A (1) Form B (1) Form C (1) Form D (1) Metal end plunger Steel roller plunger Thermoplastic roller lever (4) Steel roller lever (4) Variable length thermoplastic roller lever (4) Round thermoplastic rod lever, Ø 6 mm (4) (5) XCK J167H29 XCK J10511H29 XCK J10513H29 XCK J10541H29 XCK J10559H29 13 21 14 22 References (2) (3) 2-pole N/C + N/O XCK J161H29 snap action (XE2S P2151) 2 4,7(P) 21-22 13-14 21-22 13-14 0 13 21 21 22 22 11 12 14 0,9 6 mm 23˚ 0 mm 58˚(P) 23˚ 21-22 13-14 21-22 13-14 0 1,5 90˚ 0 11˚ ZCK J9H29 + ZCK E67 90˚ 4,7(P) 6 mm 2-pole N/C + N/C ZCK J7H29 + simultaneous, ZCK E61 slow break (XE2N P2141) 3,4(P) 31 21 13 32 22 14 0 2 13 14 mm 0 90˚ 6 mm 28˚ 23˚ mm 1,5 23˚ 21-22 13-14 0 33˚ 90˚ ZCK J9H29 + ZCK E05 + ZCK Y41 90˚ 11-12 21-22 11-12 21-22 0 90˚ 0 90˚ 11˚ ZCK J7H29 + ZCK E05 + ZCK Y13 33˚ ZCK J9H29 + ZCK E05 + ZCK Y59 23˚ 11-12 21-22 11-12 21-22 0 0 23˚ 58˚(P) 0 28˚ 90˚ ZCK JD39H29 + ZCK E05 + ZCK Y13 23˚ 90˚ 11˚ ZCK J7H29 + ZCK E05 + ZCK Y41 ZCK J7H29 + ZCK E05 + ZCK Y59 11-12 21-22 11-12 21-22 90˚ 28˚ 90˚ ZCK JD39H29 + ZCK E05 + ZCK Y41 90˚ 90˚ ZCK JD39H29 + ZCK E05 + ZCK Y59 0 90˚ 0 90 11˚ ZCK JD37H29 + ZCK E05 + ZCK Y41 23˚ 40˚(P) ZCK JD37H29 + ZCK E05 + ZCK Y59 23˚ 21-22 33-34 13-14 21-22 33-34 13-14 33˚ 28˚ 21-22 33-34 13-14 21-22 33-34 13-14 11˚ ZCK JD37H29 + ZCK E05 + ZCK Y13 0 0 23˚ 21-22 33-34 13-14 21-22 33-34 13-14 0 11˚ 3-pole ZCK JD37H29 + ZCK JD37H29 + ZCK JD37H29 + N/C + N/C + N/O ZCK E61 ZCK E67 ZCK E05 + ZCK Y11 break before make, slow 3,2(A) 5,9(P) 23˚ 40˚(P) 2 3,4(P) 21-22 21-22 21-22 break 33-34 33-34 33-34 13-14 13-14 13-14 (XE3N P2141) 0 33˚ 0 5,3 90˚ mm 0 3,2 6 0 58˚(P) 21-22 33-34 13-14 21-22 33-34 13-14 0 XCK J50559H29 62˚(P) 90˚ 21-22 33-34 13-14 21-22 33-34 13-14 0 90˚ 11-12 21-22 0 90˚ 23˚ 33˚ 62˚(P) mm XCK J50541H29 11˚ 11-12 21-22 3,5(A) 0 11˚ 21-22 13-14 11˚ ZCK J7H29 + ZCK E05 + ZCK Y11 5,9(P) 0 90˚ 23˚ 40˚(P) 0 11-12 21-22 11-12 21-22 1,5 21-22 33-34 13-14 21-22 33-34 13-14 0,9 21 0 0 11˚ 21-22 13-14 58˚(P) ZCK JD39H29 + ZCK JD39H29 + ZCK JD39H29 + 3-pole N/C + N/C + N/O ZCK E61 ZCK E67 ZCK E05 + ZCK Y11 snap action (XE3S P2141) 2 4,7(P) 3,2(A) 8,1(P) 23˚ 58˚(P) 0 31 23˚ 11-12 21-22 11-12 21-22 11-12 21-22 6 mm 21-22 33-34 13-14 21-22 33-34 13-14 22 8,1(P) ZCK J7H29 + ZCK E67 11-12 21-22 32 3,2(A) 11-12 21-22 11-12 21-22 21-22 13-14 21-22 13-14 11˚ ZCK J9H29 + ZCK E05 + ZCK Y11 23˚ 21-22 13-14 21-22 13-14 ZCK J9H29 + ZCK E05 + ZCK Y13 0,9 21 58˚(P) 2-pole N/C + N/C ZCK J9H29 + ZCK E61 snap action (XE2S P2141) 0 11 23˚ 21-22 13-14 21-22 13-14 XCK J50513H29 2 22 8,1(P) 2-pole N/C + N/O XCK J561H29 XCK J567H29 XCK J50511H29 break before make, slow 3,2(A) 5,9(P) 23˚ 40˚(P) 2 3,4(P) 21-22 21-22 21-22 break 13-14 13-14 13-14 0 5,3 mm 0 33˚ 90˚ 0 3,2 6 (XE2N P2151) mm 11-12 21-22 11-12 21-22 12 3,2(A) 21-22 13-14 21-22 13-14 90˚ 0 21-22 33-34 13-14 33˚ 90˚ mm Weight (kg) Contact operation 0.430 0.455 contact closed contact open 0.480 0.490 (A) = cam displacement (P) = positive opening point 0.485 0.485 N/C contact with positive opening operation Characteristics Switch actuation Type of actuation On end By 30° cam By any moving part Maximum actuation speed 0.5 m/s 1 m/s 1.5 m/s 30 25 30 Mechanical durability in millions of operating cycles Minimum For tripping 20 N 16 N 0.25 N.m force or For positive 50 N 40 N 0.50 N.m – torque opening Cable entry (3) 1 entry tapped M20 x 1.5 mm for ISO cable gland, clamping capacity 9 to 12 mm (1) Form conforming to EN 50041, see page 31900/9. (2) Switches with gold contacts or ring type connections: please consult your Regional Sales Office. (3) For an entry tapped for a n° 13 cable gland, delete H29 from the end of the reference. Example: XCK J161H29 becomes XCK J161. For an entry tapped for 1/2" NPT (USAS B2-1) conduit, replace H29 at the end of the reference by H7. Example: XCK J161H29 becomes XCK J161H7. (4) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting or clamp. (5) Value taken with actuator operating at 100 mm from the fixing. 37633-EN_Ver1.3.fm/2 Schneider Electric Dimensions 3 Limit switches Osiswitch® 3 Classic Metal, conforming to CENELEC EN 50041, type XCK J Complete switches, fixed body ISO M20 x 1.5 cable entry XCK Jp61H29 ZCK Jp + ZCK E61 XCK Jp67H29 ZCK Jp + ZCK E67 XCK Jp051pH29 ZCK Jp + ZCK E05 + ZCK Y11 or Y13 57 17 5 41 5 41 50 60 60 120 (1) = 33,5 30 = (1) = 33,5 40 44 30 33,5 = 40 44 XCK Jp0541H29 ZCK Jp + ZCK E05 + ZCK Y41 62 = 30 = 40 XCK Jp0559H29 ZCK Jp + ZCK E05 + ZCK Y59 52 48 44 26,2 (1) (1) 33,5 60 60 60 (3) (4) (5) 40…85 62…107 (2) 132…177 5,5 133 37 60 107 (1) 63 17 = 30 = 40 33,5 60 = 30 = 40 (1) Tapped entry for ISO M20 x 1.5 or Pg 13 cable gland or 1/2" NPT. (2) Ø 6 rod, length 200 mm. (3) 282 max. (4) 190 max. (5) 212 max. Ø: 2 elongated holes Ø 5.3 x 7.3. Schneider Electric 37633-EN_Ver1.3.fm/3 Limit switches References, characteristics Type of head 3 Osiswitch® Classic Metal, conforming to CENELEC EN 50041, type XCK J Complete switches, fixed body Integral M12 connector Plunger (fixing by the body) Type of operator 3 Rotary (fixing by the body) (switches supplied for actuation from left AND right) Form A (1) Form B (1) Form C (1) Form D (1) Metal end plunger Steel roller plunger Thermoplastic roller lever (2) Steel roller lever (2) Variable length thermoplastic roller lever (2) Round thermoplastic rod lever, Ø 6 mm (2) (3) XCK J161D XCK J167D XCK J10511D XCK J10513D XCK J10541D XCK J10559D 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 13 21 14 22 References (4) 2-pole N/C + N/O snap action (XE2S P2151) 2 3,2(A) 8,1(P) 4,7(P) 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 0 6mm 0 0 0 0 0 1,5 0,9 Weight (kg) Contact operation mm 0.430 0.455 contact closed contact open 0.480 0.490 (A) = cam displacement (P) = positive opening point 0.485 0.485 Characteristics Switch actuation Type of actuation On end By 30° cam Maximum actuation speed Mechanical durability (in millions of operating cycles) Minimum force For tripping or torque For positive opening Connection Positive operation 0.5 m/s 30 1 m/s 25 By any moving part 1.5 m/s 30 20 N 16 N 0.25 N.m 50 N 40 N 0.50 N.m – – M12 5-pin connector, Ui = 60 V, Ie = 4 A (see suitable pre-wired female connectors below). Although their design is identical to switches with cable entries, the switches incorporating an M12 5-pin connector cannot be marked with the symbol according to the standard IEC 60947-5-1, Appendix K (the insulation voltage Ui of the connector must be greater than or equal to 250 V). (1) Form conforming to EN 50041, see page 31900/9. (2) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting or clamp. (3) Value taken with actuator operating at 100 mm from the fixing. (4) Switches with gold contacts: please consult your Regional Sales Office. References of suitable pre-wired female connectors Type of connector With cable, Ø 5.8 mm (4 x 0.34 mm2 + 1 x 0.5 mm2) Weight (kg) 37634-EN_Ver1.3.fm/2 L=2m M12 straight, 5-pin, 4 A/24 V max. XZ CP1164L2 M12 elbowed, 5-pin, 4 A/24 V max. XZ CP1264L2 L=5m XZ CP1164L5 XZ CP1264L5 L = 10 m XZ CP1164L10 XZ CP1264L10 L=2m L=5m L = 10 m 0.115 0.270 0.520 Schneider Electric Limit switches Dimensions, connections Osiswitch® 3 3 Classic Metal, conforming to CENELEC EN 50041, type XCK J Complete switches, fixed body Integral M12 connector Dimensions XCK J161D XCK J1051pD XCK J167D 57 17 5 5 41 50 = XCK J10541D 30 = 33,5 40 44 = 12 33,5 = 12 30 40 44 60 60 120 133 37 60 107 = 12 33,5 41 63 17 30 = 40 62 XZ CP1164Lp XCK J10559D 52 48 44 26,2 XZ CP1264Lp 26 60 60 = 30 = 33,5 40 59 12 12 32 40 33,5 L (3) (4) 42 (2) 132…177 40…85 62…107 (1) 20 5,5 = 30 L = 40 59 (1) Ø 6 rod, length 200 mm. (2) 282 max. (3) 190 max. (4) 212 max. Ø: 2 elongated holes Ø 5.3 x 7.3. L: cable length 2, 5 or 10 m. Connections Limit switch XCK JppppD Pre-wired female connector XZ CP1p64Lp 2 2 1 1 3 4 13 21 14 22 4 1-2 = N/C 3-4 = N/O 5=t 4 A / 24 V max. 3 Schneider Electric 1 = brown 2 = white 3 = blue 4 = black 5 = t yellow/green 37634-EN_Ver1.3.fm/3 Limit switches References, characteristics Type of head 3 Osiswitch® Classic Metal, conforming to CENELEC EN 50041, type XCK J Complete switches, fixed body Integral 7/8" 16UN connector Plunger (fixing by the body) Type of operator 3 Rotary (fixing by the body) (switches supplied for actuation from left AND right) Form A (1) Form B (1) Form C (1) Form D (1) Metal end plunger Steel roller plunger Thermoplastic roller lever (2) Steel roller lever (2) Variable length thermoplastic roller lever (2) Round thermoplastic rod lever, Ø 6 mm (2) (3) XCK J161A XCK J167A XCK J10511A XCK J10513A XCK J10541A XCK J10559A 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 13 21 14 22 References (4) 2-pole N/C + N/O snap action (XE2S P2151) 2 3,2(A) 8,1(P) 4,7(P) 21-22 13-14 21-22 13-14 21-22 13-14 21-22 13-14 0 6mm 0 Weight (kg) Contact operation mm 0 0 0 0 1,5 0,9 0.430 0.455 contact closed contact open 0.480 0.490 (A) = cam displacement (P) = positive opening point 0.485 0.485 N/C contact with positive opening operation Characteristics Switch actuation Type of actuation On end By 30° cam By any moving part 0.5 m/s 1 m/s 1.5 m/s Maximum actuation speed 30 25 30 Mechanical durability (in millions of operating cycles) Minimum force For tripping 20 N 16 N 0.25 N.m or torque For positive opening 50 N 40 N 0.50 N.m – – Connection 7/8" 16UN 5-pin connector, Ui = 250 V; Ie = 6 A (see suitable pre-wired female connectors below). (1) Form conforming to EN 50041, see page 31900/9. (2) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting or clamp. (3) Value taken with actuator operating at 100 mm from the fixing. (4) Switches with gold contacts: please consult your Regional Sales Office. References of suitable pre-wired female connectors Type of connector With cable, Ø 6.7 mm (5 x 0.5 mm2) Weight (kg) 37635-EN_Ver1.3.fm/2 L=2m 7/8" 16UN straight, 5-pin, 6 A/250 V max. XZ CP1771L2 L=5m XZ CP1771L5 L = 10 m XZ CP1771L10 L=2m L=5m L = 10 m 0.190 0.475 0.950 Schneider Electric Limit switches Dimensions, connections 3 Osiswitch® 3 Classic Metal, conforming to CENELEC EN 50041, type XCK J Complete switches, fixed body Integral 7/8" 16UN connector Dimensions XCK J161A XCK J1051pA XCK J167A 57 17 5 41 5 50 60 60 120 133 37 17 17 60 107 17 = 33,5 30 = 33,5 = XCK J10541A 30 = XZ CP1771Lp 48 44 30 40 62 XCK J10559A 52 = 33,5 = 40 44 40 44 26,2 (1) 55 (2) 60 60 17 17 = 33,5 L (3) (4) 40…85 62…107 132…177 5,5 41 63 17 30 = = 33,5 40 59 30 = 40 59 (1) Ø 6 rod, length 200 mm. (2) 282 max. (3) 190 max. (4) 212 max. Ø: 2 elongated holes Ø 5.3 x 7.3. L: cable length 2, 5 or 10 m. Connections Limit switch XCK JppppA Pre-wired female connector XZ CP1771Lp 3 3 21 22 1 = 21 2 = 22 3=t 4 = 14 5 = 13 1 1 13 5 2 14 4 2 Schneider Electric 4 5 1 = black 2 = blue 3 = yellow/green t 4 = brown 5 = white 37635-EN_Ver1.3.fm/3 Limit switches References, characteristics Type of head Type of operator 3 Osiswitch® 3 Classic Metal, conforming to CENELEC EN 50041, type XCK J Complete switches, plug-in body ISO M20 x 1.5 cable entry Plunger (fixing by the body) Rotary (fixing by the body) (switches supplied for actuation from left AND right) Form A (1) Form B (1) Form C (1) Metal end plunger Steel roller plunger Thermoplastic roller lever (4) XCK J1161H29 XCK J1167H29 XCK J110511H29 XCK J110513H29 XCK J110541H29 XCK J110559H29 Steel roller lever (4) Variable length thermoplastic roller lever (4) Form D (1) Round thermoplastic rod lever, Ø 6 mm (4) (5) 13 11 14 12 References (2) (3) Single-pole C/O snap action 2 11-12 13-14 11-12 13-14 0 6mm 11-12 13-14 11-12 13-14 3,2(A) 0 0,9 Weight (kg) Contact operation 11-12 13-14 11-12 13-14 mm 0 11-12 13-14 11-12 13-14 0 11-12 13-14 11-12 13-14 0 11-12 13-14 11-12 13-14 0 1,5 0.430 contact closed 0.455 contact open Switch actuation Type of actuation On end By 30° cam Maximum actuation speed Mechanical durability (in millions of operating cycles) Minimum force or torque for tripping Cable entry (3) 0.5 m/s 30 1 m/s 25 0.480 0.490 0.485 (A) = cam displacement 0.485 Characteristics By any moving part 1.5 m/s 30 20 N 16 N 0.25 N.m 1 entry tapped M20 x 1.5 for ISO cable gland. Clamping capacity 7 to 13 mm (1) Form conforming to EN 50041, see page 31900/9. (2) Switches with gold contacts: please consult your Regional Sales Office. (3) For an entry tapped for a n° 13 cable gland, delete H29 from the end of the reference. Example: XCK J1161H29 becomes XCK J1161. For an entry tapped for 1/2" NPT (USAS B2-1) conduit, replace H29 at the end of the reference by H7. Example: XCK J1161H29 becomes XCK J1161H7. (4) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting or clamp. (5) Value taken with actuator operating at 100 mm from the fixing. 37636-EN_Ver1.3.fm/2 Schneider Electric Dimensions 3 Limit switches Osiswitch® 3 Classic Metal, conforming to CENELEC EN 50041, type XCK J Complete switches, plug-in body ISO M20 x 1.5 cable entry XCK J1611H29 XCK J1167H29 XCK J110511H29, XCK J110513H29 57 17 5 41 5 50 36 = = 30 25 62 = XCK J110541H29 (1) = 30 = 42,5 42,5 42,5 XCK J110559H29 52 5,5 60 60 127 140 37 60 114 = 30 (1) 25 (1) 25 36 41 63 17 48 26,2 44 25 60 (5) (4) 60 60 (3) 139…184 40…85 62…107 (2) (1) = 30 (1) 25 = 60 42,5 = 30 = 42,5 (1) Tapped entry for ISO M20 x 1.5 or Pg 13 cable gland or 1/2" NPT conduit. (2) Ø 6 rod, length 200 mm. (3) 289 max. (4) 190 max. (5) 212 max. Schneider Electric 37636-EN_Ver1.3.fm/3