“Tungsten Halogen”Series

advertisement
“Tungsten Halogen”Series
12V 50W Conversion Kit
石英燈電池組件
Description
Fluorescent
Tube
Self-contained, maintained type emergency power pack with
automatic changeover device for 12V 50W tungsten halogen lamp
can give out not less than 90% of normal lumen output for 2 or 3
hours emergency battery discharge. There are two LED representing
mains on and charging. The metal case is supplied for remote
mounting. It contains maintenance free sealed lead acid battery.
Variable rate charger is used to ensure the battery is always correctly
charged. Low voltage cutoff is present to prevent battery damage.
Prices do not include light fitting.
Standards
“CRYSTALITE” Cat. CC-12-50-K2
12V 50W Emergency Tungsten Halogen Lamp PowerPack, with metal housing for 2 hours duration.
• BS 5266 – Part I
• BS EN 60598-2-22 (850°
C hot wire test)
• FSD PPA 104(A) 4th Revision
Compact
Fluorescent
Connection Diagram
Maintained Type 長明式
Non-maintained Type 後備式
12V 50W lamp
Tungsten
Halogen
Tungsten
Halogen
12V 50W lamp
Tungsten
Halogen
Neutral(青線)
Non-switch
Live
Switch
Live(燈制線)
LED & ESL
Neutral(青線)
Input
Non-switch
Live
Input
Technical Data
Model
ATS
System Mode
CC-12-50-K2
CS-12-50-K2
CC-12-50-K3
CS-12-50-K3
Maintained Type
Non-Maintained Type
Maintained Type
Non-Maintained Type
Normal Output
12V 50W Tungsten Halogen Lamp
Emergency Output
Discharge Duration
Exit Sign
Battery
90%
2 Hours
3 Hours
Maintenance free sealed type Lead-Acid
12V, 12Ah
12V, 18Ah
Operating Temperature
0°C - 50°C
Transfer time
< 0.3 second
Recharge Period
Line Voltage
12 Hours
A/C 220V~230V +6%, -10% 50Hz
Low Discharge Protection
Compliance
Metal Case
41
Electronic Protection
BS EN 60598-2-22, BS 5266-1, FSD PPA 104A (4th Revision)
MB-803
340L x 200W x 70H (mm)
MB-804
362L x 200W x 90H (mm)
Self-Contained Emergency Lighting System
“Tungsten Halogen”Series
12V 75/100W Conversion Kit
石英燈電池組件
Description
Self-contained, maintained type emergency power pack
with automatic changeover device for 12V 75W/100W
tungsten halogen lamp can give out not less than 50%
of normal lumen output for 2 hours emergency battery
discharge. There are two LED representing mains on and
charging. The enclosures can be supplied for remote
mounting. It contains sealed lead acid battery and hence
maintenance free. Variable rate charger is used to ensure
the battery is always correctly charged. Low voltage
cutoff is present to prevent battery damage. Prices do
not include light fitting.
Standards
Fluorescent
Tube
“CRYSTALITE” Cat. CC-12-75-K2
12V 75W Emergency Tungsten Halogen Lamp Power-Pack,
with metal housing for 2 hours duration.
Compact
Fluorescent
• BS 5266 – Part I
• BS EN 60598-2-22 (850°
C hot wire test)
• FSD PPA 104(A) 4th Revision
Connection Diagram
Maintained Type 長明式
Tungsten
Halogen
Non-maintained Type 後備式
12V 75W/100W
Tungsten
Halogen
12V 75W/100W
Tungsten
Halogen
LED & ESL
Neutral(青線)
Non-switch
Live
Switch
Live(燈制線)
Neutral(青線)
Input
Non-switch
Live
Input
ATS
Technical Data
Model
System Mode
Normal Output
CC-12-75-K2
CS-12-75-K2
CC-12-100-K2
CS-12-100-K2
Maintained Type
Non-Maintained Type
Maintained Type
Non-Maintained Type
12V 75W Tungsten Halogen Lamp
12V 100W Tungsten Halogen Lamp
Emergency Output
50%
Discharge Duration
2 Hours
Battery
Operating Temperature
Transfer time
Recharge Period
Line Voltage
Low Discharge Protection
Exit Sign
Maintenance free sealed type Lead-Acid
12V, 12Ah
0°C - 50°C
< 0.3 second
12 Hours
A/C 220V~230V +6%, -10% 50Hz
Electronic Protection
Compliance
BS EN 60598-2-22, BS 5266-1, FSD PPA 104A (4th Revision)
Metal Case
MB-815
430L x 200W x 70H (mm)
Self-Contained Emergency Lighting System
42
“Auxi Lamp”Series
12V 50W Auxiliary Lamp Conversion Kit
Description
Metal-halide lamps are widely used in Public Area. As the wattage
of lamp is too large which is not possible to operate in emergency
mode, 12V 50W Auxiliary lamp is generally used for emergency
operation and light on when the metal-halide lamp is warming up.
Standards
Fluorescent
Tube
• BS 5266 – Part I
• BS EN 60598-2-22 (850°
C hot wire test)
• FSD PPA 104(A) 4th Revision
“CRYSTALITE” Cat. CC-12-50-K2+T
12V 50W Emergency Tungsten Halogen Lamp Power
Pack, with timer and metal housing for 2 hours duration
Connection Diagram
Compact
Fluorescent
Maintained Type 長明式
I/P 220V 50Hz
LIVE NEUTRAL
Battery Kit
Tungsten
Halogen
Luminaire
A
Luminaire
ELECTRONIC
BALLAST
L
Mains
L
Lamp
N
N
12V 50W
Tungsten Halogen Lamp
I
Bulb
I
I
LED & ESL
Metal Halide
CRYSTALITE
12V 50W
With Timer
12V 50W
METAL HALITE
Technical Data
ATS
Model
CC-12-50-K2+T
CC-12-50-K3+T
System Mode
Maintained Type
Normal Output
12V 50W Tungsten Halogen Lamp
Emergency Output
Discharge Duration
90%
2 Hours
Exit Sign
Battery
3 Hours
Maintenance free sealed type Lead-Acid
12V, 12Ah
12V, 18Ah
Operating Temperature
0°C - 50°C
Transfer time
< 0.3 second
Recharge Period
Line Voltage
12 Hours
A/C 220V~230V +6%, -10% 50Hz
Low Discharge Protection
Compliance
Metal Case
43
Electronic Protection
BS EN 60598-2-22, BS 5266-1, FSD PPA 104A (4th Revision)
MB-803
340L x 200W x 70H (mm)
MB-804
362L x 200W x 90H (mm)
Self-Contained Emergency Lighting System