ENVEL Light Emitting Diode Panels
ENVEL DESIGN CORPORATION is pleased to introduce new ENVEL LED lighting panels.
These energy efficient, state-of-the-art, and environmentally optimal light sources provide
selective levels of illumination with extremely low clearance conditions. Panel thickness of
under ½” includes a layer of proprietary ENVEL high-efficiency diffuser which provides an
exceptionally even lighting effect. Depending upon panel size, lights are situated on one, two
or four edges to achieve as consistent a light level as possible across panel face.
Types
Thickness
Single Face
(.375” LED panel + .060” diffuser)
0.4375”
LED
Max Size
Top View
Approximately 119” x 48”*
*Standard sizes up to 4’ x 8’, please inquire about oversized options.
Specifications
Description
Item
Primary Material
Diffuser Material
Min Size
Max Size
Acrylic (PMMA)
Acrylic (PMMA)
2” x 2”
Additional Information
93% transparent
H.E. ENVELITE - .060” thick
119’ x 48” *
Weight 1.95 lb. / sq. ft.
All power supplies are
Power Supply
DC 12V Adaptors
120 VAC standard
with dimming capability
Wire Size: 22 AWG 2 wire
Connector: 2.1mm x 5.5mm
Electrical Connection
Polarity: Positive Center
barrel connector
Note: Each panel must have direct connection to power supply. Do not wire panels in series.
Input Voltage
120 VAC / DC 12V
DC 24V (Optional)
Lighting Source
SMD LED
Other color temperatures
Color Temperature (CCT)
3000K, 4100K, 5300K
available
Operating Temperature
-22°F - +104°F
Power Consumption
4.0 Watts / ft. (Standard)
Constant Voltage
Lifetime
More than 50,000 hours
LED Warranty
2 years from date of shipment
Warranty on Acrylic
5 years from date of shipment
For indoor use only. Confirm Specifications with Envel Design.
www.enveldesign.com
*
805.376.8111
*
Newbury Park, CA
7/8/2016
Specification Guide for
ENVEL Light Emitting Diode Panels
Please provide LED panel size, color temperature, cord length and cord exit location information
when placing your order using the information provided below. If you don’t find the information
that you are looking for below please call one of our customer service representatives at
(805)-376-8111 and we will be happy to give you further explanation and details.
1. Size

The maximum size available is 48” x 119” and are 10 mm thick. For larger applications, plan
on placing panels side by side.

If requesting a custom shape, a drawing with dimensions is required. Custom shape must
be within overall maximum size available.

Panels can be formed, please call to confirm specifications. Panels cannot be cut in the
field. Holes can be drilled in the field, if care is taken to avoid all electrical components and
holes are drilled no closer than 1” from all edges of the panel.

Each panel will ship with a separate match-cut ENVELITE high efficiency diffuser. If holes
are to be drilled by ENVEL DESIGN, duplicate holes will be drilled into the match-cut
diffuser.
Page 1 of 3
www.enveldesign.com
*
805.376.8111
*
Newbury Park, CA
7/7/2016
Specification Guide for ENVEL L i g h t E m i t t i n g D i o d e P a n e l s
2. Color Temperature



Pure/Cool White 5300K *
Neutral White 4100K
Warm White 3000K
Example:
Profile view of ENVEL LED Light Panel
24” x 48” ENVEL LED light panel with output 5300K LEDs lit along 2 long edges (40W)
3. Cord Length



5’ power cord with 2.1mm x 5.5mm barrel plug *
10’ power cord with 2.1mm x 5.5mm barrel plug
Custom length with bare wire end
* Denotes standard configuration of rectangular or square light panel.
Page 2 of 3
www.enveldesign.com
*
805.376.8111
*
Newbury Park, CA
7/7/2016
Specification Guide for ENVEL L i g h t E m i t t i n g D i o d e P a n e l s
3. Cord Configuration
 Please specify where the cord for each panel is to exit.
 Example: Top Right, Top Center, Top Left
 If the panel is to be framed or butted against other surfaces, the cord can exit from the
back.
 Panels may be installed as close as 1mm to each other. If the cord is to exit between
adjacent panels, the cord may be set within a notched area.
 Note: Each panel must have a direct connection to the power supply. Do
not wire panels in series.
 Panels are dimmable, with standard components provided by Envel. Please indicate if
you do not need panels to be dimmable.
 The placement and spacing of LEDs will be based on size and shape of panel ordered.
Square and rectangular panels will have LEDs along 1 to 4 sides, depending on the
overall size of the panel.
Standard ENVEL LED Light Panels are for indoor use only.
When ordering, please confirm specifications with Envel Design.
Page 3 of 3
Specification Guide for ENVEL L i g h t E m i t t i n g D i o d e P a n e l s
www.enveldesign.com
*
805.376.8111
*
Newbury Park, CA
7/7/2016
ENVEL LED Light Panel Dimmer Wiring
The following Lutron wiring diagrams have been included to illustrate typical installation
conditions for both driver and dimmer hardware. All installation and wiring should be
performed by a licensed electrical contractor.
If you have any questions or concerns regarding your specific installation please contact Envel
Design and we will assist you by way of offering further detailed explanation, or by putting you in
touch with one of our trusted vendors. Envel Design has included these documents for general
reference purposes and makes no express guarantees that these hardware and installation
diagrams will relate to your specific project. Prior to purchasing or installing any lighting
hardware please consult with your electrician.
www.enveldesign.com
*
805.376.8111
*
Newbury Park, CA
6/16/2016
041-289a.ai 2/16/2011 12:00:06 PM
LED Driver Installation
Best Practices Guide
Hi-lume® A-Series
Driver Mounting
Mount driver flush against fixture to provide best heat transfer. Also, avoid mounting driver close to heat source such as fixture cover plate or light source.
K Enclosure Stud Mounting
Uses 8-32 Threaded Stud
K Enclosure Tab Mounting
M Enclosure Mounting
Correct
Incorrect
Incorrect
Incorrect
Driver must be electrically grounded for proper performance
and to meet UL® & NEC® requirements. When using
K enclosure mounting tabs, grounding should be accomplished
by using paint piercing mounting hardware to ensure electrical
connection through driver enclosure and fixture.
Power Wiring
Driver Wiring
WARNING: Shock hazard. May result in serious injury
or death. Disconnect power before servicing or installing.
Wire Strip Length
For power, output and digital terminals (E1, E2).
L3D Models
Power Input
(Line Voltage):
GND²
NEU
DH
Solid copper 18-16 AWG
(0.75 mm2 - 1.5 mm2) wire
EcoSystem® Digital Link
can be Class 1 or Class 2:¹
SH
N/C
N/C
E2
5/16 in
(8 mm)
For proper wiring:
E1
Follow wiring schematic on driver being installed.
Driver photos are for reference only.
Hi-lume A-Series, K Enclosure
C
3.00 in (76 mm) W x 1.00 in (25 mm) H x 4.90 in (124 mm) L
M
Y
CM
For use with 3-wire fluorescent controls.
MY
CY
CMY
LTE Models
GND²
NEU
N/C
DH
N/C
N/C
N/C
N/C
K
¹ NOTE: Class 2 must be separated from Class 1 and line voltage wiring by the following:
0.25 in (6 mm) or physical barrier. Please refer to App Note #142 for further information.
² NOTE: Fixture must be grounded in accordance with local and national electrical codes.
Not all enclosures include ground terminal.
1.18 in (30 mm) W x 1.00 in (25 mm) H x 14.25 in (362 mm) L
EcoSystem® Digital Link Wiring
Wire Gauge
Digital Link
Length (max)
Wire Size
Digital Link
Length (max)
12 AWG
2200 ft
4.0 mm2
828 m
14 AWG
1400 ft
2.5 mm2
517 m
16 AWG
900 ft
1.5 mm2
310 m
550 ft
2
18 AWG
1.0 mm
Load Wiring
207 m
2
0.75 mm
Hi-lume A-Series, M Enclosure
155 m
WARNING: Risk of electric shock. May result in serious
injury or death. Disconnect power before servicing
or installing.
To EcoSystem Digital
Link compatible
devices (up to 64
total drivers)
NOTE: Some models are not rated Class 2, please refer to label on
the driver being installed.
-V / Black
LED
light
source
+V
RED
-V
BLK
Driver
Terminals
LINE
E2
E1
NEU
DH
HOT
NEU
DH
HOT
LINE
Digital
Bus
E2
E1
+V / Red
Digital
Bus
10 ft (3.0 m)
Max Wire Length
Lutron Technical Support Hotline 1.800.523.9466
www.lutron.com
Lutron, EcoSystem, Hi-lume, and the Sunburst logo are registered trademarks of Lutron Electronics Co., Inc.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. UL is a registered trademark of Underwriters Laboratories, Inc.
P/N: 041-289 Rev. A 02/2011
Page 1 of 2 Page 2 of 2 ENVEL LED Light Panel Installation Guide
Mounting LED Light Panels
Mirror Clips
1. The preferred method of mounting ENVEL LED
light panels is a framing system which will
completely capture the edges of the LED Panel,
the ENVE high-efficiency diffuser and any
additional Envelex finishes.
2. It is required that a little bit of space (1/4”) be left
between the panels and wall for heat dissipation.
3. ENVEL LED light panels can be mounted by
using Mirror Clips, Z Clips, or simply screw
mounting with pre-drilled holes in the panel.
Make sure the panels are secured to prevent
damage.
(Mounting accessories are not
provided unless specifically contracted.)
Z Clips
4. White optical reflective film on reverse of panel is
NOT intended to support the weight of the panel
with contact or adhesive tapes.
5. When screw mounting the ENVEL LED light
panel drill holes a minimum of 1” from the LED
lights and heat sinks.
Screw Mount with Pre-Drilled Holes
6. ENVEL LED light panels may deform (deflect)
due to gravity if not correctly supported with
mounting products.
www.enveldesign.com
*
805.376.8111
*
Newbury Park, CA
7/8/2016
Power Cord Exit Options
Step 1 - Please select one from below:
 Standard - #1
Power cord exits from short side (edge) corner (default option when LED is shorter than 6 feet.)
 Standard - #2
Power cord exits from the middle of each long side (default option when LED is longer than 6 feet.)
July 7, 2016
Step 2 - Please select one from below:
 Option #1
Power cord exits from the back.
 Option #2
Power cord exit is recessed.
July 7, 2016
Power Cord Exit Options
Standard locations: Please choose 1 or 2 wire exit(s) from below
If wattage is < 50W = 1 wire / If wattage is <50W = 2 wires.
Please note that it is recommended that wire exits NOT be on the same side as the LED electrical
components which will run along the edge of one, two or four sides as this will result in a portion of the
edge being dark. For instance, if the LED component were to run along the top and exit at location #3 of
the illustration above the top corner would be dark. To have the complete top edge light the wire exit
would need to be at location #4.
When there are LED electrical components along all four edges the wire exits must be from the back of
the panel.
July 7, 2016
LED Dimming Driver
Hi-lumeR 1% EcoSystemT / 3-Wire L3D
Architectural Dimming
369325j
1 04.06.16
Hi-lumeR 1% EcoSystemT / 3-Wire L3D
Driver Overview
Hi-lumeR 1% EcoSystemT / 3-Wire Driver is a
high-performance LED driver that provides smooth,
continuous 1% dimming for virtually any LED fixture,
whether it requires constant-current or constant-voltage.
It is the most versatile LED driver offered today due to its
compatibility with a wide variety of LED arrays, multiple
form factors, and numerous control options.
•
•
•
•
•
•
•
•
•
•
•
•
•
Features
Continuous, flicker-free dimming from 100% to 1%.
Compatible with Energi Savr NodeT unit with
EcoSystemR, GRAFIK EyeR QS control unit, PowPakR
dimming module with EcoSystemR, and QuantumR
systems, allowing for integration into a planned or
existing EcoSystemR lighting control solution. Please see
Compatible Controls chart or contact Lutron for details
regarding compatible controls.
Standard 3-wire, line-voltage phase-control technology for
consistent dimming performance and compatibility with all
Lutron® 3-wire fluorescent controls.
QwikFigT compatible. For more information please refer
to Lutron® P/N 367-2533 (K and M case only).
Line voltage miswire protection on EcoSystemR control
inputs.
100% performance tested at factory.
A rated lifetime of 50,000 hours @:
– tc = 149 °F (65 °C) for 40 W drivers
– tc = 158 °F (70 °C) for 50 W drivers
ULR recognized and listed options for United States and
Canada.
Type TL Rated.
FCC Part 15 compliant for commercial applications
at 120 V ~ or 277 V ~.
Pulse Width Modulation (PWM) or Constant-Current
Reduction (CCR) dimming methods available. See
Application Note #360 for details.
RoHS Compliant.
For more information please go to:
www.lutron.com/hilume1led
®
Job Name:
Job Number:
S P E C I F I C AT I O N S U B M I T TA L
Model Numbers:
Case type K
3.00 in (76 mm) W x 1.00 in (25 mm) H x 4.90 in (124 mm) L
Case type M
1.18 in (30 mm) W x 1.00 in (25 mm) H x 14.25 in (362 mm) L
Case type KL
K-case mounted on a 4.00 in (102 mm) W x 1.50 in (38 mm) H
x 4.00 in (102 mm) L junction box to provide ULR listed wiring
compartment
The Hi-lumeR 1% EcoSystemT / 3-Wire family of drivers
includes models which operate at a maximum power
of 40 W or less as well as models which can operate
up to 50 W.
• 40 W or less models – output ranges A-M and X-Z
• 50 W models – output ranges N and W
(K-case only)
For a description of the output ranges please see
following pages.
Page 1
UL Listed -
L3DA4U1UKN-AV120 - UL recognized
L3D A4U1UKL-AV120
L3DA4U1UMN-AV120 - UL recognized
LED Dimming Driver
Hi-lumeR 1% EcoSystemT / 3-Wire L3D
Architectural Dimming
369325j
2 04.06.16
Specifications
Regulatory Approvals
• Meets ANSI C62.41 category A surge protection
standards up to and including 4 kV.
• FCC Part 15 compliant for commercial applications
at 120 V ~ or 277 V ~.
• Manufacturing facilities employ ESD reduction
practices that comply with the requirements of
ANSI/ESD S20.20.
• LutronR Quality Systems registered to
ISO 9001.2008.
• UL® 8750 recognized.
• UL® recognized models are also UL® classified to
1598C for field replacement capability
• UL® 8750 listed form factor available.
• Class 2 output available.
• Type TL Rated.
UL® 8750 Listed Option
• cULus® for United States and Canada available for
certain operating regions.
• Pre-wired and installation ready.
• See KL Enclosure page for more specific details
regarding UL® listed option.
Environmental
• Sound Rating: Inaudible in 27 dB ambient.
• Relative Humidity: Maximum 90% non-condensing.
• Minimum operating ambient temperature
t a = 32 °F (0 °C).
•
•
•
•
•
•
•
•
•
•
•
•
•
Performance
Dimming Range: 100% to 1%.
Operating Voltage: 120–277 V ~ at 50/60 Hz.
Lifetime: 50,000 hours @:
– tc = 149 °F (65 °C)1 for 40 W drivers.
– tc = 158 °F (70 °C)1 for 50 W drivers.
– For rated warranty, tc not to exceed the maximum
rated temperatures listed here.1
Patented thermal foldback protection.
LEDs turn on to any dimmed level without going
to full brightness.
Non-volatile memory restores all driver settings after
power failure.
Power Factor: > 0.90 for loads greater than 25 W
Standby Power Consumption: < 1.0 W
Total Harmonic Distortion (THD): < 20% for loads
greater than 25 W.
Inrush Current: < 2 A.
Inrush Current Limiting Circuitry: eliminates circuit
breaker tripping, switch arcing and relay failure.
Open circuit protected.
Short circuit protected.
• Turn-on time: ≤ 1.5 seconds. 2
• PWM Dimming Frequency: 550 Hz.
Driver Wiring & Mounting
• Driver is grounded by a mounting screw to the
grounded fixture (or by terminal connection on the
K-case).
• Terminal blocks on the driver accept one solid wire
per terminal from 18 AWG to 16 AWG
(0.75 mm2 to 1.5 mm2).
• Fixture must be grounded in accordance with local
and national electrical codes.
• For maximum driver to LED light engine wire lengths
see Driver Leads section at end of document.
1
2
Installer is responsible for ensuring that the driver case temperature does not exceed the maximum rated temperature.
Models available with turn-on time ≤ 1 second.
®
Job Name:
Job Number:
S P E C I F I C AT I O N S U B M I T TA L
Model Numbers:
Page 2
UL Listed -
L3DA4U1UKN-AV120 - UL recognized
L3D A4U1UKL-AV120
L3DA4U1UMN-AV120 - UL recognized
Related documents
Download