Occupancy Sensors ��������� OS1 OS2 APPLICATIONS Starfield’s line of low-power, low-voltage occupancy sensors are designed for easy installation and network communication. Use these sensors to meet energy code requirements for auto-off and enhanced security systems. Features include ceiling and wall mounting for maximum coverage and completely passive technology to eliminate potential hearing aid interference. reporting while direct digital control eliminates hardwired zones and power packs. Data collected with Starfield’s high-speed query capacity can be shared with other building systems or displayed graphically to create animated displays for security analysis. Optional network communication allows remote configuration and real-time FEATURES AND BENEFITS ■ ■ ■ ■ ■ ■ ■ SPECIFICATIONS Selectable logic options allows buildings to respond to changing needs and personal preference. Direct digital control simplifies installation, eliminates external power packs, and provides configuration flexibility. Coordinated interface with Starfield wall controls. Manual-on logic eliminates need for dual technology sensors in most applications. Monitor, record, share, and display occupancy data for enhanced energy savings and security. Automatic Gain Control — Dual tech acoustical sensors use patented technology to tune out constant background noise while responding to changing noise signals like talking, shuffling of papers, and general human activities 100% passive technology eliminates possible hearing aid interference. Low-voltage Electrical ■ ■ ■ Input voltage — 10-12 VDC Class 2 device DALI current 3 mA Physical and Operation ■ ■ ■ ■ ■ ■ Location: Wall and ceiling Mounting: Ceiling title or 4x4 electrical box 8-12 feet above finished floor. Colors: White Green indicator light 30 sec to 30 min internal time delay Installation requires TR33 DALI interface board or M option on TR wall controls. Environmental Operating temperature range: 0 to +55°C Storage temperature range: -10 to +85°C ■ Relative humidity: 20-90% non-condensing Warranty: Limited 2-year warranty ■ ■ 11 — Catalog 105.5 ©2004 Starfield Controls Inc. All rights reserved. Subject to change without notice. 1400 West 122nd Ave., Suite 240, Westminster CO 80234 Office 303.427.1661 ■ Fax 303.255.0701 Web: www.starfieldcontrols.com MODELS Model Fig Sensor Technology Horz View (deg) Mounting Range (ft.) Logic Application Power (mA) OS1 1 PIR 360 Ceiling 12-20 Auto/Manual 3 OS1-DT 1 PIR and Acoustic 360 Ceiling 12-20 Auto/Auto Auto/Restore 3 OS2 2 PIR 120 Wall 40 Auto/Manual 3 OS2-DT 2 PIR and Acoustic 120 Wall 40 Auto/Auto Auto/Restore 3 Logic Operation Recommended Application Warning Period Advantage Auto/Manual When covered area becomes unoccupied, lights lower to minimum setting for a 10 minute period. If occupancy is detected during the warning period lights will restore to their previous setting. Otherwise lights turn off and must be manually restarted. Private offices, conference rooms, and areas with multiple user controls that require manual override. Recommended for evening operation where security guards and cleaning crews may be present. 10 minutes Consistent, intuitive operation eliminates the need for dual technology sensors in most applications. Meets California Title 24 2005 new “on at 50% or less” requirement when used with Starfield digital dimmers. Auto/Restore When covered area becomes unoccupied, lights lower to minimum setting and stay at that setting until occupancy is detected Private offices during business hours with change to Auto/Manual during off-hours. NA Less intrusive systems generally preferred by occupants. Meets California Title 24 2005 new “on at 50% or less” requirement when used with Starfield digital dimmers. Auto/Auto When covered area becomes unoccupied, lights lower to minimum setting for a 10 minute warning period. If occupancy is detected during warning period or when lights are off they will automatically restore to previous setting. Public areas or safety and security areas without manual controls. Dual technology occupancy sensors recommended where high sensitivity setting are required. 10 minutes Automatic on Auto/Auto CA Same operation as auto/auto except that lights always turn on at 50% or less regardless of last setting. See Auto/Auto 10 minutes Automatic on. Meets California Title 24 2005 new “on at 50% or less” requirement. ORDERING OS1 — DT ���� ���� ������ �������� ������������ ��������� �� ������ Model OS1 360° ceiling mount OS2 120° wall mount �������� ���������� Technology PIR Infrared DT Infrared and Acoustic Dual Tech ��������� ������� Wiring Termination to TR33 or Starfield wall controls with M option Wiring Legend �������������� �������������������� ����������������� �������� ©2004 Starfield Controls Inc. All rights reserved. Subject to change without notice. 1400 West 122nd Ave., Suite 240, Westminster CO 80234 Office 303.427.1661 ■ Fax 303.255.0701 Web: www.starfieldcontrols.com Catalog 105.5 — 12