PROPERTY INSPECTION REPORT for: John Doe 1234 Any Street Houston, Texas 77044 PROPERTY INSPECTION REPORT Prepared For: John Doe (Name of Client) Concerning: 1234 Any Street, Houston, Texas 77044 (Address or Other Identification of Inspected Property) By: Don Davison TREC# 9825 01/10/13 (Name and License Number of Inspector) (Date) (Name, License Number and Signature of Sponsoring Inspector, if required) This property inspection report may include an inspection agreement (contract), addenda, and other information related to property conditions. If any item or comment is unclear, you should ask the inspector to clarify the findings. It is important that you carefully read ALL of this information. This inspection is subject to the rules (“Rules”) of the Texas Real Estate Commission (“TREC”), which can be found at www.trec.state.tx.us. The TREC Standards of Practice (Sections 535.227-535.233 of the Rules) are the minimum standards for inspections by TREClicensed inspectors. An inspection addresses only those components and conditions that are present, visible, and accessible at the time of the inspection. While there may be other parts, components or systems present, only those items specifically noted as being inspected were inspected. The inspector is not required to move furnishings or stored items. The inspection report may address issues that are code-based or may refer to a particular code; however, this is NOT a code compliance inspection and does NOT verify compliance with manufacturer’s installation instructions. The inspection does NOT imply insurability or warrant ability of the structure or its components. Although some safety issues may be addressed in this report, this inspection is NOT a safety/code inspection, and the inspector is NOT required to identify all potential hazards. In this report, the inspector will note which systems and components were Inspected (I), Not Inspected (NI), Not Present (NP), and/or Deficient (D). General deficiencies include inoperability, material distress, water penetration, damage, deterioration, missing parts, and unsuitable installation. Comments may be provided by the inspector whether or not an item is deemed deficient. The inspector is not required to prioritize or emphasize the importance of one deficiency over another. Some items reported as Deficient may be considered life-safety upgrades to the property. For more information, refer to Texas Real Estate Consumer Notice Concerning Recognized Hazards, form OP-I. This property inspection is not an exhaustive inspection of the structure, systems, or components. The inspection may not reveal all deficiencies. A real estate inspection helps to reduce some of the risk involved in purchasing a home, but it cannot eliminate these risks, nor can the inspection anticipate future events or changes in performance due to changes in use or occupancy. It is recommended that you obtain as much information as is available about this property, including any seller’s disclosures, previous inspection reports, engineering reports, building/remodeling permits, and reports performed for or by relocation companies, municipal inspection departments, lenders, insurers, and appraisers. You should also attempt to determine whether repairs, renovation, remodeling, additions, or other such activities have taken place at this property. It is not the inspector’s responsibility to confirm that information obtained from these sources is complete or accurate or that this inspection is consistent with the opinions expressed in previous or future reports. ITEMS IDENTIFIED IN THE REPORT DO NOT OBLIGATE ANY PARTY TO MAKE REPAIRS OR TAKE OTHER ACTIONS, NOR IS THE PURCHASER REQUIRED TO REQUEST THAT THE SELLER TAKE ANY ACTION. When a deficiency is reported, it is the client’s responsibility to obtain further evaluations and/or cost estimates from qualified service professionals. Any such follow-up should take place prior to the expiration of any time limitations such as option periods. Evaluations by qualified tradesmen may lead to the discovery of additional deficiencies which may involve additional repair costs. Failure to address deficiencies or comments noted in this report may lead to further damage of the structure or systems and add to the original repair costs. The inspector is not required to provide follow-up services to verify that proper repairs have been made. © 2009 Davison Inspections: Report for: 1234 Any Street Page 2 of 25 Property conditions change with time and use. For example, mechanical devices can fail at any time, plumbing gaskets and seals may crack if the appliance or plumbing fixture is not used often, roof leaks can occur at any time regardless of the apparent condition of the roof, and the performance of the structure and the systems may change due to changes in use or occupancy, effects of weather, etc. These changes or repairs made to the structure after the inspection may render information contained herein obsolete or invalid. This report is provided for the specific benefit of the client named above and is based on observations at the time of the inspection. If you did not hire the inspector yourself, reliance on this report may provide incomplete or outdated information. Repairs, professional opinions or additional inspection reports may affect the meaning of the information in this report. It is recommended that you hire a licensed inspector to perform an inspection to meet your specific needs and to provide you with current information concerning this property. ADDITIONAL INFORMATION PROVIDED BY INSPECTOR This inspection report is subject to the following conditions: It is made under the prevailing conditions of the items indicated in the service agreement at the time of the inspection. It is expressly understood that no warranty or guarantee of subsequent performance or condition of said item is being made by the inspector. The inspector is limited solely to those items specifically indicated herein and is also limited to patents, open and obvious defects which are concurrence readily ascertained by the visual inspection without the need to disassemble any items or remove wall coverings or other areas hidden from view. This inspection report does not guarantee meeting city building and electrical codes. By acceptance of this instrument, the customer waives any and all claims for damages, costs, expenses, repair or other liabilities against the inspector rising out of or in any way related to this inspection and the failure to report any defects in the items inspected unless caused by gross and willful negligence of the inspector. Company Relationships: As part of our commitment to service, Davison Inspections will also invite a professional inspector for termite inspections if requested to do so by the client. TEXAS REAL ESTATE CONSUMER NOTICE CONCERNING HAZARDS OR DEFICIENCIES: Each year, Texans sustain property damage and are injured by accidents in the home. While some accidents may not be avoidable, many other accidents, injuries, and deaths may be avoided through the identification and repair of certain hazardous conditions. Examples of such hazards include: • improperly installed or missing ground fault circuit protection (GFCI) devices for electrical receptacles in garages, bathrooms, kitchens, and exterior areas; • improperly installed or missing arc fault protection (AFCI) devices for electrical receptacles in family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreations rooms, closets, hallways, or similar rooms or areas; • ordinary glass in locations where modern construction techniques call for safety glass; • the lack of fire safety features such as smoke alarms, fire-rated doors in certain locations, and functional emergency escape and rescue openings in bedrooms; • excessive spacing between balusters on stairways and porches; • improperly installed appliances; • improperly installed or defective safety devices; and • lack of electrical bonding and grounding. To ensure that consumers are informed of hazards such as these, the Texas Real Estate Commission (TREC) has adopted Standards of Practice requiring licensed inspectors to report these conditions as “Deficient” when performing an inspection for a buyer or seller, if they can be reasonably determined. These conditions may not have violated building codes or common practices at the time of the construction of the home, or they may have been “grandfathered” because they were present prior to the adoption of codes prohibiting such conditions. While the TREC Standards of Practice do not require inspectors to perform a code compliance inspection, TREC considers the potential for injury or property loss from the hazards addressed in the Standards of Practice to be significant enough to warrant this notice. Contract forms developed by TREC for use by its real estate licensees also inform the buyer of the right to have the home inspected and can provide an option clause permitting the buyer to terminate the contract within a specified time. Neither the Standards of Practice nor the TREC contract form requires a seller to remedy conditions revealed by an inspection. The decision to correct a hazard or any deficiency identified in an inspection report is left to the parties to the contract for the sale or purchase of the home. © 2009 Davison Inspections: Report for: 1234 Any Street Page 3 of 25 In accordance with the Texas Real Estate Commission (TREC) Standards of Practice: some items are identified as "Deficient". Some items may be in need of repair while some may be considered possible safety hazards due to their condition or they do not appear to meet generally accepted codes of construction/installation procedures, or the equipment may be obsolete. Some items may require further evaluation and/or repair by licensed tradesmen, and some items noted should receive eventual attention with the majority of the items listed being the result of normal wear and tear. PROPERTY DESCRIPTION: This two story, wood framed single family dwelling faces west and has a combination brick veneer and cement board siding, an asphalt composition roof with attached garage. Present at Inspection Building Status Weather Conditions Utilities On Special Notes: I=Inspected I NI X X X Buyer Vacant Fair Yes NI=Not Inspected PNP X Selling agent Owner occupied Cloudy No water NP=Not Present D Listing agent Tenant occupied Rain No gas 60° Occupant Other Outside temp. No electric D=Deficient Inspection Item I. Structural Systems X X A. Foundations, Walkways and Driveways Type of foundation(s): This foundation appeared to be a slab on grade Foundation Observations: At the time of this inspection, I did not observe evidence of excessive differential deflection that would interfere with the usability or serviceability of supported structure. It is this inspector's opinion that at the time of this inspection, the foundation was performing its function; however; the following deficiencies have been identified: The foundation wall had inadequate grading clearance on the southeast wall in the front yard. Concrete foundation walls are required to extend above the finished grade adjacent to the foundation a minimum of 4”. Walkways and Driveway Observations: It is this inspector's opinion that at the time of this inspection, the walkways and driveway were performing their intended function. X X B. Grading & Drainage Grading Observations: It is this inspector's opinion that at the time of this inspection, the grading system was performing its function. Drainage Observations: It is this inspector's opinion that at the time of this © 2009 Davison Inspections: Report for: 1234 Any Street Page 4 of 25 inspection, the drainage system was performing its intended function; however; the following deficiencies have been identified: There were several locations where there was no rain gutter system which would have helped move water away from the house. above below Current and past building codes provide that all ground water within ten feet of the foundation must drain away from the house. X X C. Roof Covering Materials Type(s) of roof covering: Asphalt Shingle Viewed From: a ladder and from the ground with a monocular from all sides. Roof Covering Observations: It is this inspector's opinion that at the time of this inspection, the roof covering was performing its intended function; however; the following deficiencies have been identified: Tree branches are too close and should be trimmed to maintain a minimum of a 5feet clearance from the roof and house to prevent damages from occurring. © 2009 Davison Inspections: Report for: 1234 Any Street Page 5 of 25 X X D. Roof Structure & Attic: Viewed From: On decked area inside attic (accessed by attic access ladder located in the upstairs hallway) Approximate Average Depth of Insulation: 12” blown-in exposed 2”X6” joists Approximate Average Thickness of Vertical Insulation: not visible Roof Structure & Attic Observation: It is this inspector's opinion that at the time of this inspection, the roof structure & attic were performing their intended function; however; the following deficiencies have been identified: The attic access ladder was missing insulation as well as weather stripping. The attic door should be sealed the same as any other exterior door, helping prevent treated air from escaping into the untreated attic space. Research has shown that a non-insulated attic door drops the ceiling insulation’s R-value by 27%. © 2009 Davison Inspections: Report for: 1234 Any Street Page 6 of 25 Insulation installers are required to post the R values of the house for every 300 square feet of attic floor space. This information is missing and should be supplied and installed as required. There’s a good reason why all new homes having a pull-down attic ladder are now required to have a 350 pound weight rated ladder. It’s such an easy way to protect your family as well as anyone else (like your HVAC professional). I suggest putting the replacement of the attic ladder with a 350 lb. rated ladder towards the top of your to-do-list as a new homeowner. If the ladder is in the garage, it should also be fire rated. X X E. Walls (Interior & Exterior) Interior Walls Observations: It is this inspector's opinion that at the time of this inspection, the interior walls were performing their intended function. The interior of the house had been recently painted which would cover any water stains that may have indicated water penetration. Exterior Walls Observations: It is this inspector's opinion that at the time of this inspection, the exterior walls were performing their intended function; however; the following deficiencies have been identified: Caulking/sealant was cracking or missing at several locations. Exterior walls shall provide the building with a weather-resistant exterior wall envelope. Seal all cracks, gaps and holes in exterior walls including areas where different siding materials meet, around windows and doors, expansion joints in the brick veneer and where plumbing and wires penetrate the exterior walls. © 2009 Davison Inspections: Report for: 1234 Any Street Page 7 of 25 Cracks in the brick veneer may be indications of foundation or structural, but generally, small hair-line cracks in the mortar could be simple expansion issues, especially if there is no expansion joint anywhere in the wall. X F. Ceilings & Floors Ceiling Observations: It is this inspector's opinion that at the time of this inspection, the ceiling was performing its intended function. The interior of the house had been recently painted which would cover any water stains that may have indicated water penetration. Floor Observations: It is this inspector's opinion that at the time of this inspection, the floor was performing its intended function. X X G. Doors (Interior & Exterior) Interior Doors Observations: It is this inspector's opinion that at the time of this inspection, the interior doors were performing their intended function. Exterior Door Observations: It is this inspector's opinion that at the time of this inspection, the exterior doors were performing their intended function; however; the following deficiencies have been identified: Weather stripping materials needs adjustments or repairs on exterior doors where visible light is seen when doors are closed. daylight The door connecting the garage to the living space was not self-closing. Openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycomb core steel doors © 2009 Davison Inspections: Report for: 1234 Any Street Page 8 of 25 not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors, that are selfclosing. Garage Door Observations: It is this inspector's opinion that at the time of this inspection, the garage door was performing its intended function. X H. Windows Window Materials: X Aluminum Wood Vinyl X Single-pane glass Double-pane glass Window Operation: Double-hung X Single-hung Fixed Sliding Casement Awning Windows Observations: It is this inspector's opinion that at the time of this inspection, the windows were performing their intended function. X X I. Stairways (Interior & Exterior) Interior Stairways Observations: It is this inspector's opinion that at the time of this inspection, the interior stairway was performing its intended function; however; the following deficiencies have been identified: The space between spindles was greater than 4”. The spindle spacing should not allow a 4” sphere to pass between the spindles. The wall handrail was only 32” above the step and didn’t terminate at the wall. The handrail is required to be 34” to 38” above the step and should turn and terminate into the wall to help prevent a possible trip hazard by clothing catching on the end © 2009 Davison Inspections: Report for: 1234 Any Street Page 9 of 25 of the handrail. The risers on the steps were missing a bull-nose. Exterior Stairways Observations: N/A X X J. Fireplace/Chimney Fireplace Observations: X metal box and flue masonry / brick Fireplace Observations: It is this inspector's opinion that at the time of this inspection, the fireplace was performing its intended function; however; the following deficiencies have been identified: The refractory was not sealed at the gas line penetration. The manufacturer’s installation instructions should be followed, but these openings are generally sealed with insulation, high-temperature caulk or medium duty refractory mortar to prevent heated gasses from entering the wood framed wall. © 2009 Davison Inspections: Report for: 1234 Any Street Page 10 of 25 Chimney Observations: Since I did not walk the roof I only did a visual inspection of the chimney cap. It is this inspector's opinion that at the time of this inspection, the chimney was performing its intended function. This inspection of the fireplace is a visual inspection only, and is not a warranty and/or guarantee that the fireplace(s), chimney(s) and termination cap(s) has/have been properly or safely installed/built. X K. Porches, Balconies, Decks and Carports Observations: It is this inspector's opinion that at the time of this inspection, the deck was performing its intended function. II. Electrical Systems X X A. Service Entrance & Panels Service Entrance Observations: The electrical service entrance is a 200 amp, 120/240 volt, 3-wire, single-phase system with aluminum wiring used from the meter. The service comes from below-ground with the meter located on the northeast exterior wall. Main Service Panel Observations: There were four unused breaker openings in the panel, no visible aluminum wiring in the Branch circuits, no double-tapped breakers, and the panel appeared to be grounded. It is this inspector's opinion that at the time of this inspection, the service panel was performing its intended function; however; the following deficiencies have been identified: The ground rod was not flush with ground level and should be buried completely below grade with an approved type of clamp installed. The rod shall be installed such that the upper end of the electrodes shall be flush with or below ground. © 2009 Davison Inspections: Report for: 1234 Any Street Page 11 of 25 The circuits were not properly labeled or identified. As the circuits were not identified, it could not be determined if the circuits were properly sized for the listed appliances. Identifying circuits such as ‘bedrooms or wall outlets or light switches’ is not adequate. Labeling must be specific as to which appliances are to be protected by the over current device. It appeared that the aluminum service wiring connections were missing an antioxidant compound. Even though this is not specified in the NEC, it is considered to be a good practice in our area and TREC requires that I call this out as a deficiency. White wires being used as “hot” wires were not properly identified with black paint or tape. © 2009 Davison Inspections: Report for: 1234 Any Street Page 12 of 25 There were multiple wire connections on the neutral buss under one screw. These wires are improperly installed and when screwed into the same section may not make proper contact. Wiring should be evenly distributing on the buss with a single wire attached to each separate screw. The wiring exiting the service panel was bundled instead of allowing individual wiring to exit the panel, each through its own punch-out. Bundling of the wires produces heat, which means resistance, and may lead to a drop in amperage in the circuit. Arc-fault protection (AFCI) is missing in one or more required areas. AFCI is now required for all 15amp and 20amp electrical circuits supplying outlets installed in dwelling unit family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms or © 2009 Davison Inspections: Report for: 1234 Any Street Page 13 of 25 areas shall be protected by a listed arc-fault circuit interrupter, combination-type, installed to provide protection of the branch circuit. While this may not have been a code requirement when this property was originally constructed it is now a requirement for all TREC Licensed Inspectors to call missing AFCI protection as a deficiency. Upgrading the AFCI protection will enhance your home and your personal safety. X X B. Branch Circuits, Connected Devices and Fixtures Type of Wiring: Copper, Non-Metallic sheathed cable Branch Circuits & Connected Devices Observations: It is this inspector's opinion that at the time of this inspection, the branch circuits and connecting devices were performing their intended function. Fixture Observations: It is this inspector's opinion that at the time of this inspection, the electrical fixtures were performing their intended function; however; the following deficiencies have been identified: Exterior receptacles were weather resistant rather than weather proof. While this may not have been a code requirement when this property was originally constructed it is now a requirement for all TREC Licensed Inspectors to call weather resistant exterior receptacles as a deficiency. Upgrading the receptacles will enhance your home and your personal safety. weather resistant weather proof © 2009 Davison Inspections: Report for: 1234 Any Street Page 14 of 25 Several switch boxes as well as recptacle outlet boxes were missing faceplates or were damaged. Some light fixtures and/or bulbs did not function. These fixtures may have been missing bulbs or bulbs were burned out. © 2009 Davison Inspections: Report for: 1234 Any Street Page 15 of 25 Clothes closet lights need globe type fixtures installed to correct a fire hazard condition. A bare bulb left on over a shelf can cause a fire to occur. A globe covered type fixture or florescent light bulbs may help correct this issue. We recommend upgrading to enhance personal safety. GFCI protection was missing in one or more required locations. According to current NEC standards, all kitchen countertop receptacles must be GFCI protected, plus all bathrooms, laundry, utility and wet bar sinks (all receptacles within 6-feet of the outside edge of the sinks), all garage receptacles (including the ceiling) and all receptacles on the exterior. While this may not have been a code requirement when this property was originally constructed it is now a requirement for all TREC Licensed Inspectors to call missing GFCI protection as a deficiency. Upgrading the GFCI protection will enhance your home and your personal safety. Smoke detectors are improperly installed and/or missing. Smoke detectors shall be installed in each sleeping room, outside of each separate sleeping area in the immediate vicinity of the bedrooms and one on each additional story of the dwelling. All detectors shall be interconnected such that the actuation of one alarm will actuate all the alarms in the individual unit and shall provide an alarm which will be clearly audible in all bedrooms over background noise levels with all intervening doors closed. III. Heating, Ventilation and Air Conditioning Systems © 2009 Davison Inspections: Report for: 1234 Any Street Page 16 of 25 X X A. Heating Equipment Type of System: central, forced air system Energy Source: natural gas Heating Equipment Observations: It is this inspector's opinion that at the time of this inspection, the heating equipment was performing its intended function; however; the following deficiencies have been identified: Missing sediment trap in front of gas shut-off valve. A visual inspection of the exchanger was performed without the dismantlement of exchangers. X X B. Cooling Equipment Type of System: central, forced-air system with an exterior condenser and interior evaporator Capacity: 48,000 BTU/hr = 4 tons Cooling Equipment Observations: I was able to do an ambient test which compares the temperature of the air coming out of the supply vent to the temperature of the air going back into the return vent. There should be a range of 12° to 22° difference. The supply air average throughout the house was 67° while the intake vent read 84°, giving us an acceptable 18° difference. It is this inspector's opinion that at the time of this inspection, the cooling equipment was performing its intended function; however; the following deficiencies have been identified: The exterior cooling unit was not level at the time of the inspection, Even a 10° tilt can shorten the life of the compressor. © 2009 Davison Inspections: Report for: 1234 Any Street Page 17 of 25 Coolant line’s insulation was missing or in need of repair. X X C. Duct System, Chases and Vents Duct System Observations: It is this inspector's opinion that at the time of this inspection, the duct system, which includes chases and vents, which I was able to access, was performing its intended function; however; the following deficiencies have been identified: Observed areas where flexible duct in contact with other flexible duct. Flexible ducts should not come in contact with each other. Differences in air temperature outside and well as inside the duct could cause condensation to form. Ducts should be re-strapped or insulation should separate the area where the two ducts come in contact. © 2009 Davison Inspections: Report for: 1234 Any Street Page 18 of 25 IV. Plumbing System X X A. Water Supply System and Fixtures Location of the Water Meter: southeast corner next to street Location of Main Water Supply Valve: east wall Static Water Pressure Reading: 74 PSI Water Supply System & Fixtures Observations: It is this inspector's opinions that at the time of this inspection, the water supply and fixtures were performing their intended functions; however; the following deficiencies have been identified: One or more exterior water bib was missing an anti-siphon device. © 2009 Davison Inspections: Report for: 1234 Any Street Page 19 of 25 also had broken handle anti-siphon device Sink drain pop-up-stopper needs repair / adjustment / replacement at (location) X B. Drains, Wastes and Vents Observations: It is this inspector's opinion that at the time of this inspection, the drains, waste and vents were performing their intended functions. It should be noted that I was unable to test the wall drain in the utility room used for the washing machine. X X C. Water Heating Equipment Energy Source: natural gas Capacity: 50 gal. Observations: It is this inspector's opinion that at the time of this inspection, the water heating unit was performing its intended function; however; the following deficiencies have been identified: Water supply pipes were missing insulation. © 2009 Davison Inspections: Report for: 1234 Any Street Page 20 of 25 Missing sediment trap in front of gas shut-off valve. X X D. Hydro-Massage Therapy Equipment Observations: It is this inspector's opinion that at the time of this inspection, the spa tub was performing its intended function; however; the following deficiencies have been identified: Access to tub drain line, plumbing and motor are not accessible, which limits my inspection. Building codes require an access opening to these areas for service and repairs to this fixture and its components. © 2009 Davison Inspections: Report for: 1234 Any Street Page 21 of 25 This unit is on a dedicated circuit that is GFCI protected with the reset being located on the wall next to the toilet. This reset should be tested at least once a year to ensure proper functioning. V. Appliances X X A. Dishwasher Observations: It is this inspector's opinion that at the time of this inspection, the dishwasher was performing its intended function; however; the following deficiencies have been identified: There was no anti siphon loop or mechanical air gap in the drain pipe. An air gap or anti siphon loop is used to prevent backflow of contaminated water and bacteria from the disposer or plumbing drain back into the dishwasher. Many models come with backflow valves, but the anti siphon loop or mechanical air gap is still required. An anti siphon loop is created by forming an upside down “U” in the drain hose. The “top” of the “U” must be in contact with the bottom of the counter. The hose is the tied in place, usually to the underside of the sink or to the faucets. © 2009 Davison Inspections: Report for: 1234 Any Street Page 22 of 25 X X B. Food Waste Disposer Observations: It is this inspector's opinion that at the time of this inspection, the disposer was performing its intended function; however; the following deficiencies have been identified: The unit in the kitchen had been improperly wired. The wiring should be inside a covered junction box and secured to the body of the unit. X X C. Range Exhaust Vent Observations: It is this inspector's opinion that at the time of this inspection, the (recirculation / down-draft) exhaust vent was performing its intended function; however; the following deficiencies have been identified: The light was not functioning. © 2009 Davison Inspections: Report for: 1234 Any Street Page 23 of 25 The filter was dirty/greasy. This prevents proper circulation. X D. Ranges, Cook tops and Ovens Range/cook top: gas X electric Oven: gas X electric Oven Temperature Calibration: Set Temp°F 350 Actual Temp °F 327 Differential Temp °F 2 Observations: It is this inspector's opinion that at the time of this inspection, the cook top and oven were performing their intended function. X E. Microwave Ovens Observations: It is this inspector's opinion that at the time of this inspection, the microwave oven was performing its intended function. X F. Trash Compactor Observations: N/A X G. Mechanical Exhaust Vents and Bathroom Heaters Observations: It is this inspector's opinion that at the time of this inspection, the exhaust vents were performing their intended function. X H. Garage Door Operator(s) Observations: It is this inspector's opinion that at the time of this inspection, the garage door operator was performing its intended function. © 2009 Davison Inspections: Report for: 1234 Any Street Page 24 of 25 X I. Doorbell and Chimes Observations: It is this inspector's opinion that at the time of this inspection, the doorbell was performing its intended function. X X J. Dryer Vents Observations: It is this inspector's opinion that at the time of this inspection, the dryer vent was performing its intended function; however; the following deficiencies have been identified: The exterior cover to the vent was not properly mounted to the exterior of the house and was the wrong type cover and in need of cleaning. full of lint © 2009 Davison Inspections: Report for: 1234 Any Street Page 25 of 25