Utilities and Building Separation Family Court Center and Child Study Institute Buildings 429 Michigan Street, Toledo, Ohio Lucas County Board of Commissioners One Government Center, Suite 800, Toledo, Ohio 43604 PROJECT SITE MECHANICAL/ ELECTRICAL/ PLUMBING/ FIRE PROTECTION: mda engineering , inc . Mechanical Electrical and Telecommunications Engineers 1415 Holland Road Maumee , Ohio 43537 Phone: (419 ) 893 -3141 Fax: (419 ) 893 -0687 Project Contacts: Don Michaelis: Mechnical Brandon Stotz: Electrical Rob Yambert: Plumbing & Fire Protection INDEX OF DRAWINGS ARCHITECTURAL A0.01 LIFE SAFETY FLOOR PLANS A0.11 CSI BUILDING REMEDIATION PLAN A0.21 FIRE PROTECTION - - - - GENERAL INFORMATION - - A1.01 GROUND / MAIN FLOOR PLANS - - A1.02 2ND / 3RD FLOOR PLANS - - A1.11 ENLARGED PLANS, ELEVATIONS & WALL TYPES - - - - - - - - - - MECHANICAL - - 06.23.2015 FOR PERMIT M1.01 M1.02 M1.03 06.23.2015 FOR BIDDING 05.12.2015 FINAL OWNERREVIEW SET FP1.01 GROUND FLOOR PLAN - FIRE PROTECTION PLUMBING P1.01 P1.02 P2.01 PARTIAL SITE PLAN - PLUMBING GROUND FLOOR PLAN - PLUMBING NOTES AND DETAILS - PLUMBING MECHANICAL - GROUND FLOOR PLAN MECHANICAL - SECOND FLOOR PLAN MECHANICAL - THIRD FLOOR PLAN ELECTRICAL E0.01 E1.01 E2.01 ELECTRICAL SCHEDULES, LEGEND SPECIFICATIONS & ONE-LINE ELECTRICAL GROUND FLOOR PLAN - LIGHTING ELECTRICAL GROUND FLOOR PLAN - POWER 7 6 5 4 3 2 1 F F E E EXISTING 3-HOUR FIRE RATED WALL TO REMAIN. ALL REPAIRS AND PENETRATIONS TO MAINTAIN MINIMUM 3-HOUR FIRE-RESISTANCE RATING OF CONSTRUCTION - TYP. UP EXIT EXIT ELEV. ELEV. DN UP ELEV. DN ELEV. D2 A0.01 2nd FLOOR LIFE SAFETY SCALE: 1/32" = 1'-0" D D EXISTING 3-HOUR FIRE RATED WALL TO REMAIN. ALL REPAIRS AND PENETRATIONS TO MAINTAIN MINIMUM 3-HOUR FIRE-RESISTANCE RATING OF CONSTRUCTION - TYP. BUILDING CODE: 2011 OHIO BUILDING CODE UTILITY AND BUILDING SEPARATION TYPE OF PROJECT: (FAMILY COURT / CHILD STUDY INSTITUTE) EXISTING USE GROUP: B (NOTE: OHIO STUDY INSTITUTE BUILDING PROJECT TITLE Utilities and Building Separation CURRENTLY UNOCCUPIED.) PRIMARY OCCUPANCY CLASSIFICATION: SECONDARY OCCUPANCY CLASSIFICATION: B, CIVIC ADMINISTRATION SPECIAL OCCUPANCY CLASSIFICATION: NONE MIXED USE GROUPS: NON SEPARATED REQUIRED SEPARATION OF OCCUPANCIES NONE EXISTING CONSTRUCTION CLASSIFICATION: 2A PROPOSED CONSTRUCTION CLASSIFICATION: 2A (NO CHANGE) DN WATER FEATURE UP UP DN UP 429 Michigan St. Toledo, Ohio EXIT UP DN ELEV. ELEV. EXIT EXIT ELEV. DN UP ELEV. UP DN EXIT EXIT ELEV. ELEV. EXIT UP EXIT DN ELEV. 10'-0" +/- C C2 A0.01 FIFTH FLOOR C4 A0.01 SCALE: 1/32" = 1st FLOOR LIFE SAFETY SCALE: 1/32" = 1'-0" 1'-0" EXIT EXISTING 3-HOUR FIRE RATED WALL TO REMAIN. ALL REPAIRS AND PENETRATIONS TO MAINTAIN MINIMUM 3-HOUR FIRE-RESISTANCE RATING OF CONSTRUCTION - TYP. DN UP EXIT BASEMENT 7,690 S.F. GROUND FLOOR - MECHANICAL 6,917 S.F. GROUND FLOOR - LIBRARY 7,651 S.F. MAIN FLOOR 13,858 S.F. SECOND FLOOR 12,297 S.F. THIRD FLOOR 12,315 S.F. FOURTH FLOOR 12,054 S.F. FIFTH FLOOR 11,873 S.F. TOTAL 85,955 S.F. EXISTING BUILDING HEIGHT: EXISTING 3-HOUR FIRE RATED WALL TO REMAIN. ALL REPAIRS AND PENETRATIONS TO MAINTAIN MINIMUM 3-HOUR FIRE-RESISTANCE RATING OF CONSTRUCTION - TYP. EXIT EXIT SCALE: 1/32" = UP B2 A0.01 1'-0" GROUND FLOOR SCALE: 1/32" = 3 HOURS OCCUPANT LOAD (MAXIMUM): ELEV. FOURTH FLOOR 5 STORIES, ABOVE GRADE PROVIDED FIRE SEPARATION BETWEEN BUILDINGS: UP ELEV. ROOF AREA UP B4 A0.01 DN DN ELEV. DN B EXIT DN ELEV. PIT ELEV. DN 91'-0" EXIT EXIT EXIT UP C EXISTING BUILDING AREA: 1'-0" EXISTING 3-HOUR FIRE RATED WALL TO REMAIN. ALL REPAIRS AND PENETRATIONS TO MAINTAIN MINIMUM 3-HOUR FIRE-RESISTANCE RATING OF CONSTRUCTION - TYP. BASEMENT 26 OCCUPANTS GROUND FLOOR - MECHANICAL 23 OCCUPANTS GROUND FLOOR - LIBRARY 77 OCCUPANTS MAIN FLOOR 139 OCCUPANTS SECOND FLOOR 123 OCCUPANTS THIRD FLOOR 124 OCCUPANTS FOURTH FLOOR 121 OCCUPANTS FIFTH FLOOR 119 OCCUPANTS TOTAL 752 OCCUPANTS NUMBER OF EXITS REQUIRED: 2 NUMBER OF EXITS PROVIDED: 2 MINIMUM ALL FLOORS EXIT ACCESS TRAVEL DISTANCE: 300' FIRE SPRINKLER SYSTEM: NFPA 13, EXISTING STANDPIPES: YES SEE FP DWGS. FIRE ALARM SYSTEM: YES, EXISTING FIRE DEPARTMENT CONNECTION: SEE FP DWG. FOR LOCATION FIRE PUMP: YES 06.23.2015 BIDDING 06.23.2015 PERMIT 05.12.2015 FINAL OWNER REVIEW B CHECKED ARB APPROVED ARB TCI JOB NO. 160278 UP EXIT EXIT EXIT EXIT ELEV. LIFE SAFETY UP DN FLOOR PLANS ELEV. A UP A UP SHEET TITLE DN ELEV. A4 A0.01 A2 A0.01 THIRD FLOOR SCALE: 1/32" = BASEMENT LIFE SAFETY SCALE: 1/32" = 1'-0" 1'-0" SHEET NO. Printed 6/23/2015 A0.01 7 6 5 4 3 2 1 7 6 5 4 3 2 1 GENERAL NOTES: 3 3 1. CHILD STUDY INSTITUTE BUILDING CONTAINS KNOWN FRIABLE ACM MATERIALS THAT REQUIRE CLEANING AND REMOVAL IN ALL PATHWAYS AND AREAS OF WORK FOR DESIGNATED FOR THE BUILDING UTILITY SEPARATION. REFER TO ACM REMEDIATION REQUIREMENTS THIS SHEET. 2. REFER TO DEMOLITION DRAWINGS FOR ADDITIONAL CEILING AREAS WITHIN THE CHILD STUDY INSTITUTE TO BE REMOVED / REMEDIATED TO FACILITATE UTILITY SPEARATION PROJECT. 3. REMOVE MISC. FURNITURE / COMBUSTIBLES FOUND IN ROOMS NOT LABELED WITH SPECIFIC REMOVAL INSTRUCTIONS THROUGHOUT THE CHILD STUDY INSTITUTE. 4. OWNER RESERVES THE RIGHT TO REVIEW ALL MATERIALS INDICATED FOR REMOVAL AND DISPOSAL FROM THE CHILD STUDY INSTITUTE. OWNER MAY IDENTIFY ITEMS TO BE MOVED TO A DESIGNATED OFF-SITE LUCAS COUNTY FACILITY FOR STORAGE BY CONTRACTOR. 3 4 4 4 5 5 1 F 3 4 4 1 5 ACM REMEDIATION REQUIREMENTS: 3 3 REMOVAL OF ALL ASBESTOS CONTAINING MATERIALS / DEBRIS SHALL BE ACCOMPLISHED ACCORDING TO THE FOLLOWING REGULATIONS: 1 B1 A0.11 1 1 1 2 4 4 F B1 A0.11 B1 A0.11 1. THE OSHA ASBESTOS IN CONSTRUCTION STANDARD 29 CFR 1926.1101 2. THE USEPA ASBESTOS NESHAPs REGULATIONS 40 CFR PART 61 SECTIONS 61.141, 61.145, 61.150 AND 61.154 3. THE OHIO DEPARTMENT OF HEALTH REGULATIONS AS FOUND IN THE OHIO ADMINISTRATIVE CODE, FINAL RULE 3701-34 4. THE OHIO EPA REGULATIONS FOUND IN THE OHIO ADMINISTRATIVE CODE, FINAL RULE 3745-20 ACM REMEDIATION: ALL ACM REMEDIATION AND CLEAN MUST BE PERFORMED BY A LICENSED ASBESTOS ABATEMENT CONTRACTOR. 1 1 DESIGNATES AREA FOR ASBESTOS REMEDIATION, CLEANING AND ISOLATION FOR WORK TO BE COMPLETED AS PART OF THE UTILITY SEPERATION. MATERIALS FOR REMEDIATION ARE OUTLINED IN THE PRECONSTRUCTION ASBESTOS SURVEY, ALL WORK MUST CONFORM TO REQUIREMENTS FOR REMEDIATION OF ACM AS LISTED IN "REMEDIATION REQUIREMENTS" ON THIS SHEET. 2 DESIGNATES AREA FOR ASBESTOS REMEDIATION, CLEANING AND ISOLATION WITH ACM PLASTER CEILINGS. REMOVE DAMAGED, LOOSE, DETERIORATED OR OTHERWISE UNSECURED ACM CEILING MATERIALS HANGING OR FALLEN TO FLOOR. ALL WORK MUST CONFORM TO REQUIREMENTS FOR REMEDIATION OF ACM AS LISTED IN "REMEDIATION REQUIREMENTS" ON THIS SHEET. 3 E B1 A0.11 6 1 1 2 2 1 4 2 5 E LOOSE AND NON-BUILT-IN FURNITURE & CASEWORK REMOVAL: 1 2 3 4 1 1 B1 A0.11 4 REMOVE FILES AND RELATED MATERIALS FROM AREA INDICATED AND DISPOSE OF IN A LEGAL MANNER AS DESIGNATED BY REPRESENTATIVES OF LUCAS COUNTY. 2 REMOVE KITCHEN EQUIPMENT AND RELATED MATERIALS FROM AREA INDICATED AND RELOCATE TO NEW STORAGE OFF-SITE AS DESIGNATED BY REPRESENTATIVES OF LUCAS COUNTY. 3 REMOVE AND DISPOSE OF BEDDING/ PADS / MATTRESSES IN A LEGAL MANNER AS DIRECTED BY REPRESENTATIVES OF LUCAS COUNTY. 4 REMOVE LOOSE FURNITURE INCLUDING BUT NOT LIMITED TO WOOD OR METAL DESKS, CHAIRS, WOOD OR METAL CABINETS, WOOD BOOKCASES, STORAGE RACKS, STORED BUILDING MATERIALS, COMPUTER PARTS, PHONES, OFFICE SUPPLIES, STORED CARPENTRY TOOLS, COMMERCIAL WASHERS AND DRYERS AND RELATED MATERIALS FROM AREA INDICATED AND DISPOSE OF IN A LEGAL MANNER AS DESIGNATED BY REPRESENTATIVES OF LUCAS COUNTY. 5 REMOVE AND DISPOSE OF ALL OTHER GARBAGE AND MISC. DEBRIS OTHER THAN ACM IN A LEGAL MANNER AS DIRECTED BY REPRESENTATIVES OF LUCAS COUNTY. 5 5 4 1 4 5 5 WATER FEATURE 4 5 1 1 4 5 1 2 3 UP UP 1 UP DN UP DN UP DN ELEV. UP D ELEV. DN ELEV. D 10'-0" +/- D6 A0.11 FOURTH FLOOR REMEDIATION PLAN SCALE: 1/16" = 1'-0" THIRD FLOOR REMEDIATION PLAN D4 A0.11 SCALE: 1/16" = D2 A0.11 1'-0" 3 PROJECT TITLE Utilities and Building Separation MAIN FLOOR REMEDIATION REMOVAL PLAN SCALE: 1/16" = 1'-0" 429 Michigan St. Toledo, Ohio LINE OF EXISTING CEILING OR STRUCTURE ABOVE IF NO CEILING 3 2x4 WOOD STUDS SPACED 24" O.C. 3 4 2 4 4 5 C 5 1/2" EXPOSURE 1 GRADE OSB SHEATHING SECURED TO WOOD STUDS WITH SCREWS OR NAILS 4 5 4 C 5 1 3 4 4 1 5 4 3 3 5 1 B1 A0.11 PROVIDE CONTINUOUS WOOD BLOCKING BEHIND ALL SHEATHING PANEL JOINTS. B1 A0.11 4 5 SECURE TEMPORARY CONSTRUCTION PARTITION TO FLOOR AND WALLS WITH DRILLED EXPANSION ANCHORS. NO POWDER-ACTIVATED ANCHORS PERMITTED 1 1 LINE OF EXISTING FLOOR 1 4 2 5 1 2 1 B1 A0.11 4 5 B ASBESTOS PARTITION DETAIL SCALE: 1 1/2"= 1'-0" 06.23.2015 BIDDING 06.23.2015 PERMIT 05.12.2015 FINAL OWNER REVIEW B CHECKED ARB APPROVED ARB TCI JOB NO. 160278 4 5 1 SHEET TITLE CSI BUILDING B1 A0.11 REMEDIATION 4 1 5 DN A A ELEV. PLAN ELEV. 4 UP UP 5 Printed 6/23/2015 DN SHEET NO. A4 A0.11 7 6 SECOND FLOOR REMEDIATION PLAN SCALE: 1/16" = A2 A0.11 1'-0" 5 4 A0.11 GROUND FLOOR REMEDIATION REMOVAL PLAN SCALE: 1/16" = 1'-0" 3 2 1 7 6 5 4 3 TYPICAL MOUNTING HEIGHTS (BASED ON ICC - A117.1 - 2009) (ACCESS. DENOTES ACCESSIBLE REQUIREMENTS) SOAP DISPENSER SANITARY SANITARY NAPKIN NAPKIN RECEPTACLE DISPENSER SEAT COVER DISPENSER TOWEL DISPENSER OR MULTIPURPOSE UNIT TOWEL DISPENSER AND WASTE RECEPTACLE WASTE RECEPTACLESURFACE MOUNTED FULL LENGTH MIRROR AND BARRIER FREE MIRRORS DETAIL TITLE X 3'-4" MAX. MIRROR EDGE SCALE: 1/8" = 1'-0" AX.XX 2'-10" TOP OF TABLE WHEN OPEN 1'-6" (MAX.) 3'-4" MAX. MIRROR EDGE 6'-0" (ANSI MIN.) (MIN.) LAV MIRROR AND MIRROR AND SHELF, OR VANITY COUNTER TILTED MIRROR DOOR INDICATION DETAIL IDENTIFICATION NUMBER (SAME NUMBER ON SHEET WHERE DRAWN OR REFERENCED) 1'-8" 3'-0"± 9" (MIN.) 9" (MIN.) 5'-4" 3'-4" 3'-8" 3'-4" 3'-8" (TYP. HEIGHT) *15" A.F.F. MIN. SOAP DISH 2'-9" 1'-3" 3'-4" OPENING EDGE *REFER TO NOTE BELOW FOR CODE REQUIREMENTS F DETAIL IDENTIFICATION MIRROR SIZE AS SPECIFIED OR NOTED *ALL MIRROR DIMENSIONS ARE TO THE MIRROR GLASS SURFACE *48" A.F.F. MAX. DOOR SWING INDICATIONNEW DOOR SHEET IDENTIFICATION NUMBER (INDICATES SHEET NUMBER WHERE DETAIL IS DRAWN OR SHEET NUMBER(S) TO REFER TO WHEN REFERENCED ON THE SHEET WHERE THE DETAIL IS DRAWN) BABY CHANGING STATION ROOM NAME 000 DETAIL IDENTIFICATION NUMBER XX BOTTOM OF TACTILE CHARACTERS FIRE ALARM PULL BOX THERMOSTAT ELEVATOR PUSH BUTTONS 2'-0" (MIN.) ACCESS. URINAL 6" (MAX.) LAVATORY VANITY 1'-6" (MIN.) 4'-0" ACCESS. HANDLE HEIGHT 5'-4" 4'-0" MIN. 3/8" MIN. E.W.C. OR DRINKING FOUNTAINS LAVATORY B.F. SHOWER SEAT (DEMOLITION NOTATION) KEYED NOTE IDENTIFICATION NUMBER AS LISTED IN 'NOTES LEGEND' 10 T. (11 R.) MATERIAL OR WORK DIVISION NOTATION BARRIER FREE TRANSFER-TYPE SHOWER UNIT SIDE WALL 3'-2" MIN. 4'-0" MAX. 3" MIN. 6" MAX. 1'-6" 6" MAX. TYP. BULLETIN INDICATION OR ADDENDUM (TO BE USED FOR GENERAL REVISIONS ALSO) 1 I.G. REVISIONS THAT ARE NOT ADDENDUMS OR BULLETINS.) BULLETIN NUMBER (CURRENT REVISIONS SHALL BE SHOWN ENCIRCLED BY A FREEFORM LINE) 0 MATERIAL 'A' MATERIAL 'B' (NEW CONST.) (EXIST. CONST.) 5'-3" NOTE: DO NOT SCALE DRAWINGS WITHOUT GRAPHIC SCALES WITH PROPORTIONS OTHER THAN 1:1 DRAWING NOTATION INDICATION MATERIAL NOTATION AND INFORMATION (REFER TO TECHNICAL SPECIFICATIONS FOR MATERIAL DESCRIPTIONS AND METHODS OF CONSTRUCTION) D D INDICATES DIRECTION OF VIEW OR MULTIPLE VIEWS A-000 1 JOINT BETWEEN MATERIALS (OR CONSTRUCTION WORK DIVISION LINE) ELEVATION IDENTIFICATION NUMBER(S) (SAME LETTER ON SHEET WHERE DRAWN OR REFERENCED) 1'-4" MIN. UP (DN) STAIR DIRECTION TO FLOOR ABOVE (UP) OR BELOW (DN.) NUMBER OF TREADS (OR RISERS) IN STAIR RUN ELEVATION INDICATION 2'-3" MAX. E ASSUMED NORTH IF NOT TRUE NORTH OR PLAN NORTH WHERE TRUE NORTH IS INDICATED BY ARROW NOTATION DRAWING DIMENSION LINE INDICATION STAIR DIRECTION NOTATION SCALE: 1/8" = 1'-0" AX.XX NOTE: B.F. CONTROLS TO BE MOUNTED WITH-IN THIS AREA N (LIFE SAFETY PLAN NOTATION) ELEVATION TITLE X 18" S.S. GRAB BAR NORTH INDICATION 1. ELEVATION IDENTIFICATION NUMBER (SAME NUMBER ON SHEET WHERE DRAWN OR REFERENCED) 3'-0" MIN. 3'-5" MAX. 3'-0" MAX. 2'-9" MIN. 3'-2" MIN. 4'-0" MAX. 3'-4" STD. 6'-4" STD. 1. SHEET IDENTIFICATION NUMBER (INDICATES SHEET NUMBER WHERE ELEVATION IS DRAWN OR SHEET NUMBER(S) TO REFER TO WHEN REFERENCED ON THE SHEET WHERE THE ELEVATION IS DRAWN) WALL LINE BARRIER FREE TRANSFER-TYPE SHOWER UNIT CONTROL WALL KEYED NOTE IDENTIFICATION NUMBER AS LISTED IN 'NOTES LEGEND' ELEVATION IDENTIFICATION WALL LINE WINDOW IDENTIFICATION NUMBER (PLAN NOTATION) SHEET IDENTIFICATION NUMBER (INDICATES SHEET NUMBER WHERE SECTION IS DRAWN) WALL LINE 01 1. X A.XXX 18" S.S. GRAB BAR SHOWER HEAD AND VALVES SCALE: 1/8" = 1'-0" SECTION IDENTIFICATION NUMBER URINAL PARTITION OR WALL CONSTRUCTION (DEPTH >24") WINDOW IDENTIFICATION KEYED NOTE IDENTIFICATION NUMBER AS LISTED IN 'NOTES LEGEND' SECTION LOCATION INDICATION NOTE: B.F. CONTROLS TO BE MOUNTED WITH-IN THIS AREA 4" MAX. DESCRIPTION ORIGINATES AT WALL SURFACE DESIGNATION IF A ROOM HAS ONE DOOR OPENING, THE DOOR OPENING IS THE SAME AS THE SECURE SIDE OF THE ROOM NUMBER. IF MORE THAN ONE DOOR OPENING IN A ROOM EXISTS, DOOR OPENINGS WITHIN THAT ROOM ARE IDENTIFIED BY THE ROOM NUMBER FOLLOWED BY AN ALPHA CHARACTER STARTING CLOCKWISE FROM THE CORRIDOR ACCESS DOOR OPENING. KEYED NOTE INDICATION SHEET IDENTIFICATION NUMBER (INDICATES SHEET NUMBER WHERE SECTION IS DRAWN OR SHEET NUMBER(S) TO REFER TO WHEN REFERENCED ON THE SHEET WHERE THE SECTION IS DRAWN) 2'-3" (MIN.) HIGH-LOW E.W.C. OR DRINKING FOUNTAIN A. SECTION TITLE X AX.XX 5'-0" MIN. LENGTH HOSE WITH HAND HELD OR ADJUSTABLE SPRAY UNIT ON BAR FOLDED POSITION 1'-5" (ACCESS. MIN.) 1'-7" (ACCESS MAX.) 2'-5" (MIN.) CLEAR (MIN.) 2'-10" (MAX.) 5'-0" MIN. TO ADJACENT WALL WHEN W.C. ON COMMONWALL (MAX.) 8" CL 2'-10" (MIN.) 2'-10" (MAX.) 8" 9" (MIN.) 2'-3" (MIN.) (MIN.-ANSI (USPS) 1'-3" MIN. 3" (MAX.) 1'-3" MIN. URINAL SHOWER CL EDGE OF LAV. 2'-5" (MIN.) 1'-6" (MIN.) 5" MAX. FLUSH CONTROL STANDARD URINAL WALL CONSTRUCTION TYPE LETTER AS LISTED IN 'WALL TYPE LEGEND' SECTION IDENTIFICATION NUMBER (SAME NUMBER ON SHEET WHERE DRAWN OR REFERENCED) 1'-3" (MIN.) URINAL SHIELD (DEPTH < 24") 3'-8" MAX. 1'-5" (MAX.) 2'-9" (MIN.) 3'-0" (MAX.) 3'-8" MAX. FLUSH VALVE CL G.B. LINE OF WALL 1'-5" 1'-5" 3 1/2" MAX. PARALLEL ONLY APPROACH 1'-6" MIN. 1'-3" (MIN.) FLUSH CONTROL WATER CLOSET (ACCESS.) (MIN.-ANSI) (USPS) 1'-6" (MAX.) WALL TYPE NOTATION SECTION IDENTIFICATION 001 101 201 301 CONTINUE FOR AS MANY FLOORS REQUIRED. A FIRE EXTINGUISHER CABINET C A-000 PROJECT TITLE A Utilities and Building Separation B SHEET IDENTIFICATION NUMBER (INDICATES SHEET NUMBER WHERE ELEVATION IS DRAWN) 3'-0" MAX. 2'-9" MIN. 16" - 18" ACCESS. W.C. 17" - 19" AMBULATORY WATER CLOSET (ACCESS.) 2'-1" MAX AX.XX 2'-6" MIN. 1'-3" MAX. LINE OF WALL 5'-0" MAX. 1'-6" MIN. 2'-0" (U.N.O.) 1'-0" (MIN.) 1'-5" (MIN.) 1'-7" (MAX.) 17" (MIN.) - 19" (MAX.) (DIM. TO TOP OF SEAT) 1'-6" (MIN.) 3'-3" (MIN.) 3'-5" (MAX.) 2'-9" (MIN.) 3'-0" (MAX.) 1 1/2" (MIN.) G.B. 2'-0" (MIN.) PLAN VIEW DOOR IDENTIFICATION NUMBER BASEMENT DOORS FIRST FLOOR DOORS SECOND FLOOR DOORS THIRD FLOOR DOORS COLUMN IDENTIFICATION LETTER OR NUMBER FOR NEW CONSTRUCTION DETAIL IDENTIFICATION NUMBER XX LINE OF WALL E.W.C. OR DRINKING FOUNTAINS 3" MIN. 6" MAX. TOILET PAPER DISPENSER (ACCESS.) VERT. G.B. 3'-6" (MAX.) 1'-7" (MAX.) 1'-5" (MIN.) (MIN.-ACCESS.) 1 1/2" 1 1/2" (MIN.-ACCESS.) 1'-6" 1'-2" (MIN. 1'-7" MAX.) TOILET PAPER DISPENSER D G.B. 1 1/2" MOP STRIP AND SHELF 3'-0" MIN. 3'-6" MIN. 3'-3"(MIN.) 3'-5"(MAX) WALL MOUNTED OR EMERGENCY (ACCESS. - FRONT APPROACH) DETAIL LOCATION INDICATION FOR ENLARGED PLANS 3'-0" MIN. LINE OF WALL 1'-0" MAX. ELECTRIC DUPLEX, TELEPHONE, OR T.V. OUTLET WITH LIGHT SWITCH 2'-3" LIGHT SWITCH 3'-0" (MAX.) 1'-6" *15" A.F.F. MIN. COAT ROD AND HAT SHELF (ABOVE) 6'-0" 3'-6" (MAX.) WALL LINE WHERE INDICATED CL BOTTOM OF OUTLET 4'-0" CL CONTROLS 4'-0" (MAX.) 4'-6" (MAXIMUM) 4'-0" TOP FIRE EXTINGUISHER AND WALL BRACKET FOR CODE NOTES CL CONTROLS MIN. REQ'D. CLEARANCE 1'-6" (MIN.) 101 DOOR IDENTIFICATION BY FLOOR AND/OR ZONE SHALL BE AS FOLLOWS: 001 101 201 301 COLUMN INDICATION SHEET IDENTIFICATION NUMBER (INDICATES SHEET NUMBER WHERE DETAIL IS DRAWN) HIGH-LOW FOUNTAIN *REFER TO NOTE ABOVE *48" A.F.F. MAX. HIGH ORIFICE HT. WIDTH VARIES (REFER TO PLAN DWGS.) E 9" 9" F 101A CONTINUE FOR AS MANY FLOORS REQUIRED. SHEET IDENTIFICATION NUMBER (INDICATES SHEET NUMBER WHERE DETAIL IS DRAWN) SIGNAGE OR PLAQUE LOCATION HAND DRYER 3'-2" MIN. FACIAL TISSUE DISPENSER CONTROLS OPERABLE 1'-3" ACCESS. SHELF OR PURSE SHELF BRAILLE 3'-7" MAX. TOWEL BAR CLEAR OF DOOR SWING ELEVATION VIEW 2'-3" (MIN.) TOWEL BAR AND SHELF FORWARD APPROACH REACH RANGES REQUIRED BY CODE REGULATIONS 2'-9" 3'-8" (TYP. HEIGHT) 3'-8" 1'-3" SHELF *OPERABLE CONTROLS SHALL FALL WITHIN LOW ORIFICE HT. HIGH-LOW FOUNTAIN OR SINGLE B.F. FOUNTAIN ACCESS. HOOKS 2'-9" 4'-0" (ANSI MAX.) 1'-3" 2'-9" 5'-4" (TYPICAL HEIGHT) 6'-0" HOOKS LOWEST TEXT 3/8" MIN. UPPER TEXT *48" A.F.F. MAX. CENTER LINE OF SIGNAGE ROOM IDENTIFICATION NUMBER BASEMENT FIRST FLOOR SECOND FLOOR THIRD FLOOR (PLAN SECTIONS) DOOR SWING INDICATIONEXISTING DOOR TO BE REMOVED DOOR IDENTIFICATION ROOM IDENTIFICATION BY FLOOR AND/OR ZONE SHALL BE AS FOLLOWS: XX AX.XX (WALL SECTIONS) DOOR SWING INDICATIONEXISTING DOOR ROOM NAME AND NUMBER INDICATION DETAIL LOCATION INDICATION AX.XX SHOWER CURTAIN ROD 1 REFERENCE SYMBOLS MISCELLANEOUS ACCESSORIES, TOILET ACCESSORIES AND FIXTURES *NOTE: MOUNTING HEIGHTS SHOWN ARE PROPOSED FOR ALL ACCESSORIES AND FIXTURES REQUIRED UNLESS OTHERWISE NOTED OR DIMENSIONED ON DRAWINGS FOR SPECIFIC CONDITIONS 2 MATCH LINE INDICATION STANDARD ROLL-IN TYPE SHOWER - BACK WALL SHEET IDENTIFICATION NUMBER (INDICATES SHEET NUMBER OF DRAWING) A1.1 ZONE `A' ZONE `A' A1.1 A1.2 ZONE `B' ZONE `B' A1.2 429 Michigan St. Toledo, Ohio SHEET IDENTIFICATION NUMBER (INDICATES SHEET NUMBER WHERE DRAWING IS CONTINUED) ABBREVIATIONS C A ABV AFF AFG AFS ASC ABRSV ABSORB ACS PNL ACST ACT ACOUS INSUL APC AWT ADDM ADDNL ADH ADJ ADMIN AGGR ACCU A/C AAP AC UNIT AHU ALT ALT NO ALUM/AL AMT AMP AMPL AHR AB & or ANOD APT APPRD APPROX ARCH AAWI B AD ATM ASPH ASSY @ AV AUTO AUX AVG ABOVE ABOVE FINISH FLOOR ABOVE FINISH GRADE ABOVE FINISH SLAB ABOVE SUSPENDED CEILING ABRASIVE ABSORPTION ACCESS PANEL ACOUSTIC ACOUSTIC CEILING TILE ACOUSTIC INSULATION ACOUSTIC PANEL CEILING ACOUSTIC WALL TREATMENT ADDENDUM ADDITIONAL ADHESIVE ADJUSTABLE / ADJACENT ADMINISTRATION AGGREGATE AIR COOLED CONDENSING UNIT AIR CONDITIONING ALARM ANNUNCIATOR PANEL AIR CONDITIONING UNIT AIR HANDLING UNIT ALTERNATE ALTERNATE NUMBER ALUMINUM AMOUNT AMPERE AMPLIFIER ANCHOR ANCHOR BOLT AND ANGLE ANODIZED APARTMENT APPROVED APPROXIMATE ARCHITECT/ARCHITECTURAL ARCHITECTURAL DRAWING-NO. ARCHITECTURAL WOODWORKING INSTITUTE AREA DRAIN AUTOMATIC TELLER MACHINE ASPHALT ASSEMBLY AT AUDIO VISUAL AUTOMATIC AUXILIARY AVERAGE B B/B BFP BDD BBR B PL BSMT BM BC BRG BRG PL BLW BFF BM BTWN BEV BITUM BD BLR BS BW BOT BLVD BDRY BRKT BRKR BTU BRZ BLDG BL BUR BULL BB BLKHD BN Printed 6/23/2015 A 7 BACK-TO-BACK BACK FLOW PREVENTER BACK DRAFT DAMPER BASE BOARD RADIATION BASE PLATE BASEMENT BEAM BACK OF CURB BEARING BEARING PLATE BELOW BELOW FINISH FLOOR BENCH MARK BETWEEN BEVEL BITUMINOUS BOARD BOILER BOTH SIDES BOTH WAYS BOTTOM BOULEVARD BOUNDARY BRACKET BREAKER BRITISH THERMAL UNIT BRONZE BUILDING BUILDING LINE BUILT-UP ROOFING BULLETIN BULLETIN BOARD BULKHEAD BULLNOSE CAB CUH CTV CAP CPT CO CSMT CSWK CSG CI CIP CAT NO CB CATW CAV CLG CLG DIFF CLG GRL CLG HT CEM CEM FIN CBB CEM PLAS CTR C OR CL C TO C CER CT CTB CTF CH BD CHFR C CHWR CHWS CH CIR CRCMF CKT CKT BRKR CCL CLRM CO CLR CL CLWG CLO CLOS CH COAX COEFF CFMF CW COL CLL CO COMPT CPRS CA COMPR CMPTR CONC CONC FLR CMU PCCP CP CSP CND CONF CONN CONSTR CM CONT CTR CNTR CNTOR CF CFE CF/OI CLL CTRL CJ CP COORD CNR CG CORR CU CNTR CSK CABINET CABINET UNIT HEATER CABLE TELEVISION CAPACITY CARPET CASED OPENING CASEMENT CASEWORK CASING CAST IRON CAST IRON PIPE/CAST-IN-PLACE CATALOG NUMBER CATCH BASIN CATWALK CAVITY CEILING CEILING DIFFUSER CEILING GRILLE CEILING HEIGHT CEMENT CEMENT FINISH CEMENTITOUS (BACKER) BOARD CEMENT PLASTER CENTER CENTERLINE CENTER-TO-CENTER CERAMIC CERAMIC TILE CERAMIC TILE BASE CERAMIC TILE FLOOR CHALKBOARD CHAMFER CHANNEL CHILLED WATER RETURN CHILLED WATER SUPPLY CHILLER CIRCLE CIRCUMFERENCE CIRCUIT CIRCUIT BREAKER CIVIL DRAWING-NO. CLASS CLASSROOM CLEAN OUT CLEAR CLOSE CLEAR WIRE GLASS CLOSET CLOSURE COAT HOOK COAXIAL CABLE COEFFICIENT COLD- FORMED METAL FRAMING COLD WATER PIPING COLUMN COLUMN LINE COMPANY COMPARTMENT COMPRESSIBLE COMPRESSED AIR COMPRESSOR COMPUTER CONCRETE CONCRETE FLOOR CONCRETE MASONRY UNIT CONCRETE PAVEMENT CONCRETE PIPE CONCRETE SEWER PIPE CONDUIT CONFERENCE CONNECT CONSTRUCTION CONSTRUCTION MANAGEMENT CONTINUE/CONTINUOUS CONTOUR CONTRACT CONTRACTOR CONTRACTOR FURNISHED CONTRACTOR FURNISHED EQUIPMENT CONTRACTOR FURNISHED/ OWNER INSTALLED CONTRACT LIMIT LINE CONTROL CONTROL JOINT/ CONSTRUCTION JOINT CONTROL PANEL COORDINATE CORNER CORNER GUARD CORRIDOR/CORRUGATED COPPER COUNTER COUNTERSINK 6 CFLG COV COV PL CUB CU FT CFM CU YD CYL C&G CI COUNTER FLASHING COVER COVER PLATE CUBICAL CUBIC FEET/ CUBIC FOOT CUBIC FEET PER MINUTE CUBIC YARD CYLINDER CURB AND GUTTER CURB INLET D DMPR DMPF DL dB D DEL DEMO DPTN DEPT DSGN DET DIAG DIA or Ø DIFF DIM DR DIR DISC DW DISP DIST DISTR PNL DIV DR DR CL DR OPNG DBL DBL ACT DR DH DN DS DR DT DWR DWG DF DSP DUPL DTDR DAMPER DAMPPROOFING DEAD LOAD DECIBEL DEEP DELETE / DELIVER DEMOLISH, DEMOLITION DEMOUNTABLE PARTITION DEPARTMENT DESIGN DETAIL DIAGONAL / DIAGRAM DIAMETER DIFFUSER / DIFFERENCE DIMENSION DINING ROOM DIRECTION DISCONNECT DISHWASHER DISPENSER DISTANCE DISTRIBUTION PANEL DIVIDER/DIVISION DOOR DOOR CLOSER DOOR OPENING DOUBLE DOUBLE ACTING DOOR DOUBLE HUNG DOWN DOWNSPOUT DRAIN DRAIN TILE DRAWER DRAWING DRINKING FOUNTAIN DRY STAND PIPE DUPLICATE DUTCH DOOR E EA EF EW ESMT E EP EOS ELAST ELEC EC EEP EWC EL ELEV EMER ENCL ENGR ENTR EPDM EPT EQ EQL SP EQUIP EQUIV ESCAL EST EXC EXH EXH DT EXH FN EXH GR EACH EACH FACE EACH WAY EASEMENT EAST EDGE OF PAVEMENT EDGE OF SLAB ELASTOMERIC ELECTRIC/ELECTRICAL ELECTRICAL CONTRACTOR ELECTRICAL DRAWING-NO. ELECTRICAL PANEL ELECTRIC WATER COOLER ELEVATION ELEVATOR EMERGENCY ENCLOSURE ENGINEER ENTRANCE/ENTRY ETHYLENE PROPYLENE DIENE MONOMER EPOXY PAINT EQUAL EQUALLY SPACED EQUIPMENT EQUIVALENT ESCALATOR ESTIMATE EXCAVATED EXHAUST EXHAUST DUCT EXHAUST FAN EXHAUST AIR GRILLE EXH EAR EXIST EXIST GR ERD EXP EXP BT EJ EXP EXTN EXT EIFS EXTRU EGSB EXHAUST AIR HOOD EXHAUST AIR REGISTER EXISTING EXISTING GRADE EXISTING ROOF DRAIN EXPANSION EXPANSION BOLT EXPANSION JOINT EXPOSED EXTENSION EXTERIOR EXTERIOR INSULATION FINISH SYSTEM EXTRUSION EXTERIOR GYPSUM SHEATHING BOARD F FAB FC BRK FOC FOF FOM FOS F/F FCU FS FSTNR FAS FDR FT or ' FPM FN FRG FGL FRP FIG FC FIN FIN FLR FFEL FIN FLR FIN GR FTR FA FAAP FACP FDMPR FE FEC FHC FH FRA FR FRTW FPL FP FIXT FLASH FHMS FHWS FLR FLG FAR FCO FD FLR FIN FLR SK FLUOR FLDG FT FTG FDTN FR FRMG FRZ FA FR GL FFA FFB FS FURN FURG FBO FF&E FUT FABRIC FACE BRICK FACE OF CONCRETE / CURB FACE OF FINISH FACE OF MASONRY FACE OF STUDS FACE-TO-FACE FAN COIL UNIT FAR SIDE FASTENER FASCIA FEEDER FEET/FOOT FEET PER MINUTE FENCE FIBER REINFORCED GYPSUM FIBERGLASS FIBERGLASS REINFORCED PLASTIC FIGURE FILE CABINET FINISH/FINISHED FINISH FLOOR FINISHED FLOOR ELEVATION FINISHED FLOOR FINISHED GRADE FINNED TUBE RADIATION FIRE ALARM FIRE ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL FIRE DAMPER FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FIRE HYDRANT FIRE RATED ASSEMBLY FIRE RATING / FIRE RESISTANCE FIRE RETARDANT TREATED WOOD FIREPLACE FIREPROOF / FLAG POLE FIXTURE FLASHING FLAT HEAD MACHINE SCREW FLAT HEAD WOOD SCREW FLOOR FLOORING FLOOR AREA RATIO FLOOR CLEAN OUT FLOOR DRAIN FLOOR FINISH FLOOR SINK FLUORESCENT FOLDING FOOT, FEET FOOTING FOUNDATION FRAME FRAMING FREEZER FRESH AIR FRITTED GLASS FROM FLOOR ABOVE FROM FLOOR BELOW FULL SIZE / FULL SCALE FURNISH/FURNISHED FURRING/FURRED FURNISHED BY OTHERS FURNITURE, FIXTURE & EQUIPMENT FUTURE 5 G GA GAL GPH GPM GALV GI GALV STL G LN GEN GEN COND GC GL GFRC GFRG GFRP GFRP GLZ CMU GSU GLZ GB GR BM GRTG GRAN GT GRL G GFCI GT GUT GDR GYP BD GAUGE GALLON GALLONS PER HOUR GALLONS PER MINUTE GALVANIZED GALVANIZED IRON GALVANIZED STEEL GAS LINE GENERAL GENERAL CONDITIONS GENERAL CONTRACTOR GLASS GLASS- FIBER REINFORCED CONCRETE GLASS- FIBER REINFORCED GYPSUM GLASS- FIBER REINFORCED PLASTER GLASS- FIBER REINFORCED PLASTIC GLAZED CONCRETE MASONRY UNIT GLAZED STRUCTURAL UNIT GLAZING GRAB BAR GRADE BEAM GRATING GRANITE GREASE TRAP GRILLE GROUND GROUND FAULT CIRCUIT INTERRUPTER GROUT GUTTER GUARD RAIL GYPSUM BOARD INSTL INSUL INT INV INT EL INSTALL INSULATION INTERIOR INVERT INVERT ELEVATION JAN CLO JS J-BOX JR JANITOR CLOSET JANITOR SINK JUNCTION BOX JUNIOR J K KPL KW KIT KB KD KOP L LAB LAD LAM LAM GL LDG LGE LAU LAV LH LIB LT LTG LT GA LP LP LTG PNL LTWT LWC LMST LD LF LIQ LL LR LOC LKR LLH LLV LVR LPT LBR LBS or # H HD HS HCP HNDRL HDW HDWD HD JT HDR HA GL HVAC HTWS HTWR HD HT HEX H HDDE HEPA HID HP HS HV HWY HO HC HM HMD HMF HORIZ HP HB HC HOSP HW HWB HWR HWS HR HSKPG HYD HYDR HAND DRYER HAND SINK HANDICAPPED HANDRAIL HARDWARE HARDWOOD HEAD JOINT HEADER HEAT ABSORBING GLASS HEATING, VENTILATING, & AIR CONDITIONING HEATING WATER SUPPLY HEATING WATER RETURN HEAVY DUTY HEIGHT HEXAGON HIGH HIGH DENSITY POLY ETHYLENE HIGH EFFICIENCY PARTICLE AIR FILTER HIGH INTENSITY DISCHARGE HIGH PRESSURE / HIGH POINT HIGH STRENGTH HIGH VOLTAGE HIGHWAY HOLD OPEN HOLLOW CORE HOLLOW METAL HOLLOW METAL DOOR HOLLOW METAL FRAME HORIZONTAL HORSEPOWER HOSE BIBB HOSE CABINET HOSPITAL HOT WATER HOT WATER BOILER HOT WATER RETURN HOT WATER SUPPLY HOUR HOUSE KEEPING HYDRANT HYDRAULIC LABORATORY LADDER LAMINATE LAMINATED GLASS LANDING LARGE LAUNDRY LAVATORY LEFT HAND LIBRARY LIGHT LIGHTING LIGHT GAUGE LIGHT POLE LIGHTPROOF LIGHTING PANEL LIGHTWEIGHT LIGHTWEIGHT CONCRETE LIMESTONE LINEAR DIFFUSER LINEAR FEET/FOOT LIQUID LIVE LOAD LIVING ROOM LOCATION LOCKER LONG LEG HORIZONTAL LONG LEG VERTICAL LOUVER LOW POINT LUMBER POUNDS M MACH MB MACH RM MAU MGT MAINT MH MFR MFD MO MATL MAX MECH MMECH RM MC MC MED MDO MEMB MWP MTL I ID INCAND. IN or " INCL. INFO ID IF IFS KICK PLATE KILOWATT KITCHEN KNEE BRACE KNOCK DOWN KNOCK-OUT PANEL IDENTIFICATION INCANDESCENT INCH/INCHES INCLUDE/INCLUDING INFORMATION INSIDE DIAMETER / DIMENSION INSIDE FACE INSIDE FACE OF STUD 4 MACHINE MACHINE BOLT MACHINE ROOM MAKE-UP AIR UNIT MANAGEMENT MAINTENANCE MANHOLE MANUFACTURER MANUFACTURERED MASONRY OPENING MATERIAL MAXIMUM MECHANICAL MECHANICAL DRAWING-NO. MECHANICAL ROOM MECHANICAL CONTRACTOR MEDICINE CABINET MEDIUM MEDIUM DENSITY OVERLAY MEMBRANE MEMBRANE WATERPROOFING METAL ML ML & P MT MEZZ MF MLWK MIN MIRR MISC MR MOD MOD BIT MON MBH MOD MLDG MTD MTG MVBL MULL M METAL LATH METAL LATH AND PLASTER METAL THRESHOLD MEZZANINE MILL FINISH MILLWORK MINIMUM MIRROR MISCELLANEOUS MOISTURE RESISTANCE MODEL MODIFIED BITMEN MONUMENT MOP / BROOM HOLDER MOTOR OPERATED DAMPER MOLDING MOUNTED MEETING/MOUNTING MOVEABLE MULLION THOUSAND (1000) N NAT NG NS NEUT NRC NOM NRP NORM N NIC NTS NO or # NATURAL NATURAL GAS NEAR SIDE / NARROW STILE NEUTRAL NOISE REDUCTION COEFFICIENT NOMINAL NON REMOVABLE NORMAL NORTH NOT-IN-CONTRACT NOT-TO-SCALE NUMBER O O GL OFF OCC OC OPQ OPNG OPP OPH ORIG ORN OZ O/O OA OAD OAG OAI OD OF OFS OA ORD OH OH DR OF/CI OF/OI O OBSCURE GLASS OFFICE OCCUPY ON CENTER OPAQUE OPENING OPPOSITE OPPOSITE HAND ORIGINAL ORNAMENTAL OUNCE OUT-TO-OUT OUTSIDE AIR OUTSIDE AIR DAMPER OUTSIDE AIR GRILLE OUTSIDE AIR INTAKE OUTSIDE DIAMETER / DIMENSION OUTSIDE FACE OUTSIDE FACE STUDS OVERALL OVERFLOW ROOF DRAIN OVERHANG OVERHEAD DOOR OWNER FURNISH / CONTRACTOR INSTALL OWNER FURNISH / OWNER INSTALL OXYGEN P PT PR PNL PTD PTDR PTR PAR PRKG P BD PTN PVG PED PER FT PERF PERIM PAINT PAIR PANEL PAPER TOWEL DISPENSER PAPER TOWEL DISPENSER AND RECEPTACLE PAPER TOWEL RECEPTACLE PARALLEL / PARAPET PARKING PARTICLE BOARD PARTITION PAVING PEDESTAL PER FOOT (OR INCH) PERFORATED PERIMETER 3 PERM PERP or PH or O PHOTO PC PIL PLAS PLAM PL GL PLAT PLBG PLYWD PT PC PI PL POL PVC PORC PORC ENAM PORT POS PIV # / LB PLF PSF PSI PCF PWR PRCST PREFAB PREFIN PT PRV PRI PROJ PROP PL PA PSH PB PP PP PL T C PERMANENT PERPENDICULAR PHASE PHOTOGRAPH PIECE PILASTER PLASTER PLASTIC LAMINATE PLATE GLASS PLATFORM PLUMBING PLYWOOD POINT OF TANGENCY POINT OF CURVATURE POINT OF INTERSECTION POLYETHYLENE (PLASTIC) POLISH/POLISHED POLYVINYLCHLORIDE PORCELAIN PORCELAIN ENAMEL PORTABLE POSITION POST INDICATOR VALVE POUND POUNDS PER LINEAR FOOT POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POUNDS PER CUBIC FOOT POWER PRECAST PREFABRICATED PREFINISHED PRESERVATIVE TREATED PRESSURE REDUCING VALVE PRIMARY PROJECT/PROJECTION PROPERTY PROPERTY LINE PUBLIC ADDRESS PURSE SHELF PUSH BUTTON / PULL BOX PUSH / PULL PUSH / PULL PLATE Q QUAL QTY QT QTB QTF QTR QTR RND QUALITY QUANTITY QUARRY TILE QUARRY TILE BASE QUARRY TILE FLOOR QUARTER QUARTER ROUND R RAB R R RWL RLG RR RECD RECPT RCPTN REC REC RDC RWD REF REFL RCP REF REG REINF REM REP REPL REQD RESIL RB RF RET RA RAD RA FAN RABBETED RADIUS RAIN WATER LEADER RAILING RAILROAD RECEIVED RECEPTACLE RECEPTION RECESSED RECTANGLE/RECTANGULAR REDUCER REDWOOD REFERENCE REFLECT REFLECTED CEILING PLAN REFRIGERATOR REGISTER REINFORCE REMOVE/REMOVABLE REPAIR REPLACE REQUIRED RESILIENT RESILIENT BASE RESILIENT FLOORING RETURN RETURN AIR RETURN AIR DUCT RETURN AIR FAN RA GR REV RPM R RH ROW RD RFG RD RH RL RV RFG RTU RM RO RND or O RHMS RHWS RBR RTF RETURN AIR GRILLE REVISED/REVISION REVOLUTIONS PER MINUTE RISER RIGHT HAND RIGHT OF WAY ROAD ROOFING ROOF DRAIN ROOF HATCH ROOF LEADER ROOF VENTILATOR / VENT ROOFING ROOF TOP UNIT ROOM ROUGH OPENING ROUND ROUND HEAD MACHINE SCREW ROUND HEAD WOOD SCREW RUBBER RUBBER TILE FLOOR S SDL SADDLE SAN SANITARY SND SANITARY NAPKIN DISPENSER SNDU SANITARY NAPKIN DISPOSAL UNIT SS SANITARY SEWER SCHED SCHEDULE SJ SCORED JOINT SCRN SCREEN SCP SCUPPER SLNT SEALANT SHTHG SHEATHING SECT SECTION SVCE SERVICE SHT SHAFT SHFT SHAFT (ELEVATION) SS SERVICE SINK SHT SHEET SM SHEET METAL SHT MTL FLASH SHEET METAL FLASHING SV SHEET VINYL SHR SHOWER SCR SHOWER CURTAIN ROD SIM SIMILAR SGL SINGLE SK SKETCH SKLT SKYLIGHT SM SMALL SMK SMOKE SD SMOKE DETECTOR SD SOAP DISPENSER SC SOLID CORE SCWD SOLID CORE WOOD DOOR SAFB SOUND ATTENUATION FIRE BLANKET STC SOUND TRANSMISSION CLASS S SOUTH SPKR SPEAKER SPEC SPECIFICATIONS SB SPLASH BLOCK SP EL SPOT ELEVATION SPKLR SPRINKLER SQ SQUARE SF SQUARE FEET/SQUARE FOOT STAG STAGGERED SST STAINLESS STEEL ST STAIRS / STREET STD STANDARD SS STANDING SEAM (ROOF) SP STANDPIPE ST PR STATIC PRESSURE STA STATION STM STEAM STL STEEL STL JST STEEL JOIST STL LNTL STEEL LINTEL STL PL STEEL PLATE STL RF DK STEEL ROOF DECK STL TR STEEL TRUSS STL TB STEEL TUBING STIF STIFFENER SD STORM DRAIN STOR STORAGE STR STRAIGHT ST STREET STRUCT STRUCTURAL SSTRUCTURAL DRAWING-NO. 2 STRUCT STL SUB SP SMP SAG SD SF SPRT SURF SUSP SW SWBD SWGR SYM SYMM SYS STRUCTURAL STEEL SUBSTITUTE SUMP PIT SUMP PUMP SUPPLY AIR GRILLE SUPPLY DIFFUSER/ DUCT SUPPLY FAN SUPPORT SURFACE SUSPEND SWITCH SWITCHBOARD SWITCHGEAR SYMBOL SYMMETRICAL SYSTEM T TK BD TAN TECH TEL TV TEMP TMPD GL TER TB TSTAT R THK THRESH THRU TPD TPH T& G T& B TOC TE TO TOF TOM TOP TOP TOR TOS TOW TOPO TB TD TDR TG XFMR TRANS T TD TYP TACKBOARD TANGENT TECHNICAL TELEPHONE TELEVISION TEMPERATURE TEMPERED GLASS TERRAZZO TEST BORING THERMOSTAT THERMAL RESISTANCE THICK/ THICKNESS THRESHOLD THROUGH TOILET PAPER DISPENSER TOILET PAPER HOLDER TONGUE AND GROOVE TOP AND BOTTOM TOP OF CURB / TOP OF CONCRETE TOP ELEVATION TOP OF TOP OF FOOTING TOP OF MASONRY TOP OF PARAPET TOP OF PAVEMENT TOP OF RIM TOP OF STEEL / SLAB TOP OF WALL TOPOGRAPHY TOWEL BAR TOWEL DISPENSER TOWEL DISPENSER / RECEPTACLE TRANSFER GRILLE TRANSFORMER TRANSOM TREAD TRENCH DRAIN TYPICAL VTR VENT VIF VS VERT VEST VIB VCT VWC VCT VOL VD V VENT THRU ROOF VENTILATOR / VENTILATION VERIFY IN FIELD VERSUS VERTICAL/ VERTICALLY VESTIBULE VIBRATION VINYL COMPOSITION TILE VINYL WALL COVERING VITRIFIED CLAY TILE VOLUME VOLUME DAMPER VOLTS C W WSCT W CAB WCO WH W/W WHSE WF W WTR WC WL WH WM WPM WP WR WS WH WT WWF WWM W W Wx_ W GL WM w/ w/o WD WB WBL WP WI WAINSCOT WALL CABINET WALL CLEAN OUT WALL HYDRANT WALL-TO-WALL WAREHOUSE WASH FOUNTAIN WASTE/ WATTS WATER WATER CLOSET WATER LINE WATER HEATER WATER METER WATER PROOF MEMBRANE WATERPROOFING WEATHER RESISTANCE WEATHERSTRIP WEEP HOLE WEIGHT WELDED WIRE FABRIC WELDED WIRE MESH WEST WIDE/ WIDTH WIDE FLANGE SECTION WIRED GLASS WIRE MESH WITH WITHOUT WOOD / WOOD DOOR WOOD BASE WOOD BLOCKING WORKING POINT WROUGHT IRON UC UCD UFD UGND UL UNFIN UH UNO UR. UTIL UP UNDERCUT UNDER CUT DOOR UNDER FLOOR DUCT UNDER GROUND UNDERWRITER'S LABORATORY UNFINISHED UNIT HEATER UNLESS NOTED OTHERWISE URINAL UTILITY UTILITY POLE 06.23.2015 PERMIT 05.12.2015 FINAL OWNER REVIEW CHECKED ARB APPROVED ARB TCI JOB NO. 160278 X X BRACE XL CROSS BRACE EXTRA LARGE SHEET TITLE YD YCO YD YR GENERAL YARD YARD CLEAN OUT YARD DRAIN YEAR Z ZC ZINC V VAC VB VR VAV VF VFD VAR VNR VP VS BIDDING B Y U 06.23.2015 INFORMATION A SHEET NO. VACUUM / VACUUM LINE VACUUM BREAKER VAPOR RETARDER VARIABLE AIR VOLUME VARIABLE FREQUENCY VARIABLE FREQUENCY DRIVE VARIATION / VARIES VENEER VENEER PLASTER VENT STACK A0.21 1 7 6 5 4 3 2 1 DEMOLITION DESIGNATIONS: DOORS: D-1: REMOVE DOUBLE DOORS ADDITIONAL NOTES FOR DOORS: 1. CONTRACTOR SHALL INCLUDE REMOVAL AND SALVAGE OF EXISTING DOOR HARDWARE AS FOLLOWS FROM ALL DOORS TO BE REMOVED: A. LOCKSETS B. PANIC HARDWARE - ALL ABOVE HARDWARE ARE ITEMS TO BE DELIVERED TO OWNER. ANY OTHER HARDWARE ITEMS TO BE DISPOSED OF OFF-SITE BY THE CONTRACTOR. DOOR FRAMES PLAYGROUND DF-1: REMOVE HOLLOW METAL OR STEEL DOOR FRAME ADDITIONAL NOTES FOR DOOR FRAMES: F F 1. CONTRACTOR SHALL INCLUDE REMOVAL OR CUTTING OF EXISTING DOOR FRAME ANCHORS, SHIMS AND THRESHOLDS TO PROVIDE A CLEAN, CLEAR OPENING FOR NEW CONSTRUCTION. CSI WALLS AND PARTITONS: C4 A4 A1 A1.01 A1.01 C1 A1.01 A1.01 W-1: REMOVE CONCRETE MASONRY UNIT (CMU) WALL - 4",6",8",10" AND/OR 12" THICK EXPOSE EXISTING SUBSTRATE. REMOVE GLUE, MORTAR, ANCHORS, ETC. ASSOCIATED WITH WALL COVERING TO PROVIDE A SMOOTH SURFACE FOR NEW CONSTRUCTION. ADDITIONAL NOTES FOR WALLS AND PARTITIONS: FCC 1. SEE ARCHITECTURAL FLOOR PLANS FOR THICKNESS OF WALL WHERE APPLICABLE C4 A4 WINDOWS AND LOUVERS: C1 A1 A1.02 A1.02 A1.02 A1.02 WIN-1: REMOVE EXISTING ALUMINUM WINDOW INCLUDING FRAME, GLASS, ALL ASSOCIATED INTERIOR AND EXTERIOR ALUMINUM TRIM AND SEALANTS. AREAWAY RAISED PLANTER AREA L-1: REMOVE EXISTING MECHANICAL LOUVER INCLUDING FRAME, ALL ASSOCIATED INTERIOR AND EXTERIOR TRIM AND SEALANTS. EXISTING OPENING TO BE PREPARED FOR INSTALLATION OF NEW 3-HR RATED WALL INFILL, REMOVE ALL MATERIALS NECESSARY FOR INSTALLATION OF NEW 3-HR CMU INFILL. ADDITIONAL NOTES FOR WINDOWS AND CURTAIN WALL: E2 A1.01 E CSI BUILDING 1. REMOVE OR CUT EXISTING WINDOW, WALL ANCHORS AND SHIMS TO PROVIDE A CLEAN, CLEAR OPENING FOR NEW CONSTRUCTION. AREA OF SIDEWALK REMOVAL. REFER TO A1.01 - A4/C4 FOR ADDITIONAL INFORMATION AND SCOPE. SITE PLAN SCALE: 1" = 40' E FCC BUILDING ACM ACOUSTICAL PLASTER CEILING TO BE REMOVED AS REQUIRED TO ACCESS PIPES AND DUCTWORK. NOTE: CSI BUILDING WALL AND CEILING FINISH MATERIAL ARE IDENTIFIED AS ASBESTOS-CONTAINING-MATERIAL (ACM). CONTRACTOR IS RESPONSIBLE FOR SECURING LICENSED ABATEMENT CONTRACTOR FOR REMOVAL OF MATERIALS IN AREAS WHERE WORK SCOPE SHOWN ON CONTRACTOR DOCUMENTS WILL RESULT IN POSSIBE DISTURBING OF THESE ACM MATERIALS. CSI BUILDING FCC BUILDING DN D DN WATER FEATURE D-1 DN DF-1 UP UP NOTE: CSI BUILDING WALL AND CEILING FINISH MATERIAL ARE IDENTIFIED AS ASBESTOS-CONTAINING-MATERIAL (ACM). CONTRACTOR IS RESPONSIBLE FOR SECURING LICENSED ABATEMENT CONTRACTOR FOR REMOVAL OF MATERIALS IN AREAS WHERE WORK SCOPE SHOWN ON CONTRACTOR DOCUMENTS WILL RESULT IN POSSIBE DISTURBING OF THESE ACM MATERIALS. W-1 L-1 DN DN D UP D-1 UP ELEV. UP DF-1 D-1 DN ELEV. UP UP DN PROJECT TITLE ELEV. PIT UP DN ACM REMEDIATION REQUIRED FOR ALL PIPE, DUCT OR CONDUIT SHOWN OR REQUIRED TO BE REMOVED THAT HAS BEEN IDENTIFIED AS CONTAINING ACM INSULATION (SEE REPORT). SEE A0.11 FOR REMEDIATION REQUIREMENTS. NOTE: 10'-0" +/REMOVE EXISTING CONCRETE SIDEWALK AS NECESSARY TO INSTALL NEW DOMESTIC WATER TAP AND LINE. CUT AT EXISTING CONC. JOINTS, PROTECT EXISTING CURB AND PROVIDE REQUIRED PEDESTRIAN BLOCKADES. 15'-0" +/- NOTE: C Utilities and Building Separation ELEV. ELEV. COORDINATE REMOVAL OF EXISTING CEILINGS WITH AREAS OF WORK SHOWN OR INDICATED ON FP, M, P & e DRAWINGS. CONTRACTOR SHALL COORDINATE WORK INCLUDING REINSTALLING CEILING SYSTEMS, GRIDS, TILES OR SUPPORT FRAMING AND GYPSUM BOARD TO MATCH ORIGINAL CONDITIONS PRIOR TO DEMOLITION. NOTE: 429 Michigan St. Toledo, Ohio ACM REMEDIATION REQUIRED FOR ALL PIPE, DUCT OR CONDUIT SHOWN OR REQUIRED TO BE REMOVED THAT HAS BEEN IDENTIFIED AS CONTAINING ACM INSULATION. SEE A0.11 FOR REMEDIATION REQUIREMENTS. NOTE: EXISTING CURB C4 A1.01 MAIN FLOOR DEMOLITION PLAN SCALE: 1/16" = C1 A1.01 1'-0" 18 17 16 15 CSI BUILDING 14 13 12A 12 11 10 9 8 7 6 5 4 3 2 GROUND FLOOR DEMOLITION PLAN SCALE: 1/16" = C 1'-0" 1 18 17 16 15 FCC BUILDING CSI BUILDING EXISTING 3-HOUR FIRE RATED WALL TO REMAIN. ALL REPAIRS AND PENETRATIONS TO MAINTAIN MINIMUM 3-HOUR FIRE-RESISTANCE RATING OF CONSTRUCTION - TYP. COORDINATE REMOVAL OF EXISTING CEILINGS WITH AREAS OF WORK SHOWN OR INDICATED ON FP, M, P & e DRAWINGS. CONTRACTOR SHALL COORDINATE WORK INCLUDING REINSTALLING CEILING SYSTEMS, GRIDS, TILES OR SUPPORT FRAMING AND GYPSUM BOARD TO MATCH ORIGINAL CONDITIONS PRIOR TO DEMOLITION. 14 13 12A 12 11 10 9 8 7 6 5 4 3 2 1 FCC BUILDING EXISTING 3-HOUR FIRE RATED WALL TO REMAIN. ALL REPAIRS AND PENETRATIONS TO MAINTAIN MINIMUM 3-HOUR FIRE-RESISTANCE RATING OF CONSTRUCTION - TYP. L L L A2 L A1.11 DN H H DN WATER FEATURE A1 UP ASBESTOS ABATEMENT PARTITION SEE A0.11 J F ELEV. G UP F ELEV. UP DN C B A 14 15'-0" +/- 18 17 16 15 13 EXISTING FIRE ALARM CONTROL PANEL TO REMAIN 12A 12 11 10 9 8 7 5 4 3 2 1 18 17 16 15 Printed 6/23/2015 EXISTING CURB A4 A1.01 MAIN FLOOR PLAN SCALE: 1/16" = 7 A1 A1.01 1'-0" 6 5 4 ARB D GROUND / MAIN B 14 13 CORE DRILL NEW HOLE IN WALL FOR 4" DOMESTIC WATER LINE. REFER TO SHEET P1.02. SEAL PENETRATION WATER-TIGHT AFTER INSTALLATION IS COMPLETE. 12A 12COORDINATE 11 10WITH PLUMBING CONTRACTOR. 9 8 7 6 5 4 3 2 1 A A1.01 1'-0" 3 FLOOR PLANS SHEET NO. GROUND FLOOR PLAN SCALE: 1/16" = APPROVED SHEET TITLE A EXISTING MASTER CLOCK TO REMAIN. 6 EXISTING EDP, SEE ELEC. DWGS. A REPLACE REMOVED CONCRETE SIDEWALK PER CITY OF TOLEDO STANDARD CONSTRUCTION DOCUMENTS, SHEET 37. INFILL TRENCH PER C.O.T. STANDARD CONSTRUCTION DOCUMENTS SHEET 43. ARB E C B A 10'-0" +/- CHECKED F ELEV. C B FINAL OWNER REVIEW G D C 05.12.2015 TCI JOB NO. 160278 UP D ELEV. H UP DN ELECTRICAL PANEL - SEE ELEC. DWGS E DN D PERMIT NEW GYP. BD. CEILING TO SEAL CORRIDOR FROM EXISTING SHAFT. EXISTING PIPE OPENINGS TO BE CLOSED. SEE MECHANICAL & PLUMBING DRAWINGS FOR SIZE AND NUMBER. F E UP E J DN TOOTH IN CMU TO INFILL DOOR OPENING G UP DN H DN G D4 A1.11 E6 A1.11 J 06.23.2015 B TOOTH IN 3 HR RATED CMU IN OPENING TO FIT NEW FIRE RATED DOOR. 3'-4" J BIDDING K ASBESTOS ABATEMENT PARTITION, SEE A0.11 A1.11 A K 5'-0"+/- B K ELEV. PIT K UP 06.23.2015 2 1 7 6 5 4 3 2 1 DEMOLITION DESIGNATIONS: DOORS: D-1: REMOVE DOUBLE DOORS ADDITIONAL NOTES FOR DOORS: 1. CONTRACTOR SHALL INCLUDE REMOVAL AND SALVAGE OF EXISTING DOOR HARDWARE AS FOLLOWS FROM ALL DOORS TO BE REMOVED: A. LOCKSETS B. PANIC HARDWARE - ALL ABOVE HARDWARE ARE ITEMS TO BE DELIVERED TO OWNER. ANY OTHER HARDWARE ITEMS TO BE DISPOSED OF OFF-SITE BY THE CONTRACTOR. DOOR FRAMES DF-1: REMOVE HOLLOW METAL OR STEEL DOOR FRAME ADDITIONAL NOTES FOR DOOR FRAMES: F F 1. CONTRACTOR SHALL INCLUDE REMOVAL OR CUTTING OF EXISTING DOOR FRAME ANCHORS, SHIMS AND THRESHOLDS TO PROVIDE A CLEAN, CLEAR OPENING FOR NEW CONSTRUCTION. WALLS AND PARTITONS: W-1: REMOVE CONCRETE MASONRY UNIT (CMU) WALL - 4",6",8",10" AND/OR 12" THICK EXPOSE EXISTING SUBSTRATE. REMOVE GLUE, MORTAR, ANCHORS, ETC. ASSOCIATED WITH WALL COVERING TO PROVIDE A SMOOTH SURFACE FOR NEW CONSTRUCTION. ADDITIONAL NOTES FOR WALLS AND PARTITIONS: 1. SEE ARCHITECTURAL FLOOR PLANS FOR THICKNESS OF WALL WHERE APPLICABLE WINDOWS AND LOUVERS: WIN-1: REMOVE EXISTING ALUMINUM WINDOW INCLUDING FRAME, GLASS, ALL ASSOCIATED INTERIOR AND EXTERIOR ALUMINUM TRIM AND SEALANTS. L-1: REMOVE EXISTING MECHANICAL LOUVER INCLUDING FRAME, ALL ASSOCIATED INTERIOR AND EXTERIOR TRIM AND SEALANTS. EXISTING OPENING TO BE PREPARED FOR INSTALLATION OF NEW 3-HR RATED WALL INFILL, REMOVE ALL MATERIALS NECESSARY FOR INSTALLATION OF NEW 3-HR CMU INFILL. ADDITIONAL NOTES FOR WINDOWS AND CURTAIN WALL: 1. REMOVE OR CUT EXISTING WINDOW, WALL ANCHORS AND SHIMS TO PROVIDE A CLEAN, CLEAR OPENING FOR NEW CONSTRUCTION. E CSI BUILDING FCC BUILDING CSI BUILDING E FCC BUILDING WIN-1 EXISTING LIGHTWELL TO REMAIN UNLESS NOTED OTHERWISE. NOTE: CSI BUILDING WALL AND CEILING FINISH MATERIAL ARE IDENTIFIED AS ASBESTOS-CONTAINING-MATERIAL (ACM). CONTRACTOR IS RESPONSIBLE FOR SECURING LICENSED ABATEMENT CONTRACTOR FOR REMOVAL OF MATERIALS IN AREAS WHERE WORK SCOPE SHOWN ON CONTRACTOR DOCUMENTS WILL RESULT IN POSSIBE DISTURBING OF THESE ACM MATERIALS. NOTE: CSI BUILDING WALL AND CEILING FINISH MATERIAL ARE IDENTIFIED AS ASBESTOS-CONTAINING-MATERIAL (ACM). CONTRACTOR IS RESPONSIBLE FOR SECURING LICENSED ABATEMENT CONTRACTOR FOR REMOVAL OF MATERIALS IN AREAS WHERE WORK SCOPE SHOWN ON CONTRACTOR DOCUMENTS WILL RESULT IN POSSIBE DISTURBING OF THESE ACM MATERIALS. WIN-1 CEILINGS TO BE REMOVED AS REQUIRED TO ACCESS PIPES, DUCTWORK AND OTHER REMOVALS. CEILINGS TO BE REMOVED AS REQUIRED TO ACCESS PIPES AND DUCTWORK. CEILINGS TO BE REMOVED TO ACCESS PIPES AND DUCTWORK, WITH POSSIBLE ACM INSULATION ABOVE CEILING REMOVE MASONRY AT REMOVED DUCTWORK AS REQUIRED TO ALLOW SEALING OF DUCTWORK IN SHAFT. REMOVE MASONRY AT REMOVED DUCTWORK AS REQUIRED TO ALLOW SEALING OF DUCTWORK IN SHAFT. D UP DN UP ELEV. ELEV. C4 A1.02 C NOTE: NOTE: COORDINATE REMOVAL OF EXISTING CEILINGS WITH AREAS OF WORK SHOWN OR INDICATED ON FP, M, P & e DRAWINGS. CONTRACTOR SHALL COORDINATE WORK INCLUDING REINSTALLING CEILING SYSTEMS, GRIDS, TILES OR SUPPORT FRAMING AND GYPSUM BOARD TO MATCH ORIGINAL CONDITIONS PRIOR TO DEMOLITION. THIRD FLOOR DEMOLITION PLAN C1 A1.02 1'-0" 18 17 16 15 CSI BUILDING PROJECT TITLE 14 13 12A 12 11 10 9 ELEV. DN ELEV. ACM REMEDIATION REQUIRED FOR ALL PIPE, DUCT OR CONDUIT SHOWN OR REQUIRED TO BE REMOVED THAT HAS BEEN IDENTIFIED AS CONTAINING ACM INSULATION (SEE REPORT). SEE A0.11 FOR REMEDIATION REQUIREMENTS. SCALE: 1/16" = ELEV. UP UP ELEV. DN NOTE: 8 7 6 5 3 4 2 ACM REMEDIATION REQUIRED FOR ALL PIPE, DUCT OR CONDUIT SHOWN OR REQUIRED TO BE REMOVED THAT HAS BEEN IDENTIFIED AS CONTAINING ACM INSULATION (SEE REPORT). SEE A0.11 FOR REMEDIATION REQUIREMENTS. NOTE: Utilities and Building Separation COORDINATE REMOVAL OF EXISTING CEILINGS WITH AREAS OF WORK SHOWN OR INDICATED ON FP, M, P & e DRAWINGS. CONTRACTOR SHALL COORDINATE WORK INCLUDING REINSTALLING CEILING SYSTEMS, GRIDS, TILES OR SUPPORT FRAMING AND GYPSUM BOARD TO MATCH ORIGINAL CONDITIONS PRIOR TO DEMOLITION. 429 Michigan St. Toledo, Ohio SECOND FLOOR DEMOLITION PLAN SCALE: 1/16" = 18 17 16 15 FCC BUILDING C 1'-0" 1 CSI BUILDING EXISTING 3-HOUR FIRE RATED WALL TO REMAIN. ALL REPAIRS AND PENETRATIONS TO MAINTAIN MINIMUM 3-HOUR FIRE-RESISTANCE RATING OF CONSTRUCTION - TYP. 14 13 12A 12 11 10 9 8 7 6 5 4 3 2 1 FCC BUILDING EXISTING 3-HOUR FIRE RATED WALL TO REMAIN. ALL REPAIRS AND PENETRATIONS TO MAINTAIN MINIMUM 3-HOUR FIRE-RESISTANCE RATING OF CONSTRUCTION - TYP. L L A3 L L EXISTING LIGHTWELL TO REMAIN UNLESS NOTED OTHERWISE. TYP. REINSTALL OR CONSTRUCT NEW CEILINGS TO MATCH EXISTING. A1.11 K B D DN CEILINGS TO BE REMOVED TO ACCESS PIPES AND DUCTWORK, WITH POSSIBLE ACM INSULATION ABOVE CEILING K K K WALL PENETRATIONS TO BE CMU IN-FILLED AND FIRE RATED, SEE SHEET M1.02 REINSTALL OR CONSTRUCT NEW CEILINGS TO MATCH EXISTING. J H J J J H H H DN UP G G PERMIT 05.12.2015 FINAL OWNER REVIEW CHECKED ARB APPROVED ARB DN G G F F E E D D C C C C B B B B A A A A ELEV. ELEV. ELEV. F ELEV. UP E UP E D D ELEV. DN DN ELEV. A SHEET TITLE 2ND / 3RD FLOOR PLANS A 18 17 16 15 Printed 6/23/2015 06.23.2015 TCI JOB NO. 160278 WALL PENETRATIONS TO BE CMU IN-FILLED AND FIRE RATED, SEE SHEET M1.03 F BIDDING B WALL PENETRATIONS TO BE CMU IN-FILLED AND FIRE RATED, SEE SHEET M1.03 UP 06.23.2015 A4 A1.02 14 13 12A 12 11 10 9 8 7 6 5 4 3 2 1 18 17 16 15 THIRD FLOOR PLAN SCALE: 1/16" = A1 A1.02 1'-0" 7 6 5 4 14 13 12A 12 11 10 9 8 7 6 5 4 3 2 1 SHEET NO. SECOND FLOOR PLAN SCALE: 1/16" = A1.02 1'-0" 3 2 1 7 6 5 4 3 2 BOTTOM OF STRUCTURE TOP OF WALL BRACING SYST. (TYP.) BOTTOM OF STRUCTURE TOP OF WALL BRACING SYST. (TYP.) SEE STRUC. SLIP LEG TRACK SECTION VIEW SEE DWGS. FOR BOND BEAM LOCATIONS REMOVE ANY EXISTING MECHANICAL DUCTWORK IN AREA OF SHAFTWALL ENCLOSURE, SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION CEILING LINE CEILING LINE CEILING LINE 4 1/4" 1" GYPSUM LINER PANELS F BOTTOM OF STRUCTURE SECTION COMPRESSABLE FILL VIEW FIRESAFING AS REQ'D TO MEET FIRE RATING EXISTING SHAFT OPENING 1 12" NOMINAL CMU SEE PLAN F 12" NOMINAL CMU SEE PLAN 3 5/8" 25GA. MIN. MTL STUDS @ 16" O.C. (USE 6" STUDS AS NOTED ON PLAN) PLAN VIEW 2 1/2" C-H STUDS 25 GUAGE @ 24" O.C. 5/8" GYP BD VERT. BAR REINF. SEE STRUCT. VERT. BAR. REINF. SEE STRUCT. PLAN VIEW 3 1/2" FIBERGLASS BATT INSULATION 2 LAYERS 1/2" FIRECODE C CORE GYPSUM PANELS, FACE LAYER JOINTS FINISHED SECTION VIEW DEMOLITION DESIGNATIONS: FLOOR RUNNER TRACK DOORS: D-1: REMOVE DOUBLE DOORS BXUV.U904 - Fire-resistance Ratings - ANSI/UL 263 ADDITIONAL NOTES FOR DOORS: DOOR FRAMES DF-1: REMOVE HOLLOW METAL OR STEEL DOOR FRAME ADDITIONAL NOTES FOR DOOR FRAMES: 8'-0" E U 8'-0" THRU WALL PENETRATIONS TO BE 1. CONTRACTOR SHALL INCLUDE REMOVAL AND SALVAGE OF EXISTING DOOR HARDWARE AS CMU IN-FILLED AND FIRE RATED, SEE MEP DRAWINGS FOR MORE FOLLOWS FROM ALL DOORS TO BE REMOVED: INFORMATION AND SCOPE. A. LOCKSETS B. PANIC HARDWARE NEW 2-HR RATED SUSPENDED GYP. BD. CEILING AND - ALL ABOVE HARDWARE ARE ITEMS TO BE DELIVERED TO OWNER. ANY OTHER HARDWARE SOFFIT TO CLOSE OFF EXISTING MECH. SHAFT. ITEMS TO BE DISPOSED OF OFF-SITE BY THE CONTRACTOR. TOP OF FLOOR TOP OF FLOOR Page 1 of 1 CMU FULL HEIGHT UL. #U904 3-HR- Fire Resistance Ratings - ANSI/UL 263 BXUV CMU C-3 CMU FULL HEIGHT S A GYP. BD./METAL STUD BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada 3-HR RATED CMU INFILL AND NEW FIRE RATED DOOR NEW 3 HOUR RATED CMU IN-FILLED WALL E BOTTOM OF STRUCTURE See General Information for Fire-resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design No. U904 NEW FIRE RATED DOOR May 26, 2015 1. CONTRACTOR SHALL INCLUDE REMOVAL OR CUTTING OF EXISTING DOOR FRAME ANCHORS, SHIMS AND THRESHOLDS TO PROVIDE A CLEAN, CLEAR OPENING FOR NEW CONSTRUCTION. Bearing Wall Rating — 3 HR. Nonbearing Wall Rating — 3 HR. WALLS AND PARTITONS: GROUND FLOOR WEST INT. ELEV. This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7 W-1: REMOVE CONCRETE MASONRY UNIT (CMU) WALL - 4",6",8",10" AND/OR 12" THICK EXPOSE EXISTING SUBSTRATE. REMOVE GLUE, MORTAR, ANCHORS, ETC. ASSOCIATED WITH WALL COVERING TO PROVIDE A SMOOTH SURFACE FOR NEW CONSTRUCTION. E6 A1.11 TOP OF FLOOR SECTION VIEW SCALE: 1/8" = * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. 1'-0" ADDITIONAL NOTES FOR WALLS AND PARTITIONS: FLOOR LINE 1. SEE ARCHITECTURAL FLOOR PLANS FOR THICKNESS OF WALL WHERE APPLICABLE WINDOWS AND LOUVERS: DEMOLITION DESIGNATIONS: WIN-1: REMOVE EXISTING ALUMINUM WINDOW INCLUDING FRAME, GLASS, ALL ASSOCIATED INTERIOR AND EXTERIOR ALUMINUM TRIM AND SEALANTS. DOORS: D4 A1.11 L-1: REMOVE EXISTING MECHANICAL LOUVER INCLUDING FRAME, ALL ASSOCIATED D-1: REMOVE DOORS INTERIOR AND DOUBLE EXTERIOR TRIM AND SEALANTS. EXISTING OPENING TO BE PREPARED FOR INSTALLATION OF NEW 3-HR RATED WALL INFILL, REMOVE ALL MATERIALS NECESSARY FOR ADDITIONAL NOTES FOR3-HR DOORS: INSTALLATION OF NEW CMU INFILL. WALL SECTION 1. Concrete Blocks* — Various designs. Classification C-3 (3 hr). SCALE: 3/4" = See Concrete Blocks category for list of eligible manufacturers. 1'-0" SEALANT FIRE SEALANT 2. Mortar — Blocks laid in full bed of mortar, nom. 3/8 in. thick, of not less than 2-1/4 and not more than 3-1/2 parts of clean sharp sand to 1 part Portland cement (proportioned by volume) and not more than 50 percent hydrated lime (by cement volume). Vertical joints staggered. 1. CONTRACTOR SHALL AND SALVAGE ADDITIONAL NOTES FOR INCLUDE WINDOWSREMOVAL AND CURTAIN WALL: OF EXISTING DOOR HARDWARE AS FOLLOWS FROM ALL DOORS TO BE REMOVED: LOCKSETS 1. A. REMOVE OR CUT EXISTING WINDOW, WALL ANCHORS AND SHIMS TO PROVIDE A CLEAN, B. PANIC HARDWARE CLEAR OPENING FOR NEW CONSTRUCTION. - ALL ABOVE HARDWARE ARE ITEMS TO BE DELIVERED TO OWNER. ANY OTHER HARDWARE ITEMS TO BE DISPOSED OF OFF-SITE BY THE CONTRACTOR. 3. Portland Cement Stucco or Gypsum Plaster — Add 1/2 hr to Classification if used. Attached to concrete bolcks (Item 1). D 4. Loose Masonry Fill — If all core spaces are filled with loose dry expanded slag, expanded clay or shale (Rotary Kiln Process), water repellant vermiculite masonry fill insulation, or silicone treated perlite loose fill insulation add 1 hr to Classification. 5. Foamed Plastic* — (Optional-Not Shown) — 1-1/2 in. thick max, 4 ft wide sheathing attached to concrete blocks (Item 1). DOOR FRAMES 7'-0" +/- FIELD VERIFY D EXISTING WALL ATLAS ROOFING CORP — "EnergyShield Pro Wall Insulation" and "EnergyShield Pro 2 Wall Insulation." DF-1: REMOVE HOLLOW METAL OR STEEL DOOR FRAME CARLISLE COATINGS & WATERPROOFING INC — Type R2+ Sheath ADDITIONAL NOTES FOR DOOR FRAMES: 1. CONTRACTOR SHALL INCLUDE REMOVAL OR CUTTING OF EXISTING DOOR FRAME ANCHORS, SHIMS AND THRESHOLDS TO PROVIDE A CLEAN, CLEAR OPENING FOR NEW CONSTRUCTION. HUNTER PANELS — Type Xci-Class A, Xci 286 WALLS AND PARTITONS: PROJECT TITLE RMAX OPERATING L L C — "TSX-8500", "TSX-8510", "Thermasheath-XP", "ECOMAXci", "Thermasheath-3", "Durasheath-3" THE DOW CHEMICAL CO — Type Thermax Sheathing, Thermax Light Duty Insulation, Thermax Heavy Duty Insulation, Thermax Metal Building Board, Thermax White Finish Insulation, Thermax ci Exterior Insulation, Thermax XARMOR ci Exterior Insulation, Thermax IH Insulation, Thermax Plus Liner Panel, Thermax Heavy Duty Plus (HDP) and TUFF-R™ ci Insulation ADDITIONAL NOTES FOR WALLS AND PARTITIONS: Utilities and Building Separation U W-1: REMOVE CONCRETE MASONRY UNIT (CMU) WALL - 4",6",8",10" AND/OR 12" THICK EXPOSE EXISTING SUBSTRATE. REMOVE GLUE, MORTAR, ANCHORS, ETC. ASSOCIATED WITH WALL COVERING TO PROVIDE A SMOOTH SURFACE FOR NEW CONSTRUCTION. 1. SEE ARCHITECTURAL FLOOR PLANS FOR THICKNESS OF WALL WHERE APPLICABLE 5A. Building Units — As an alternate to Item 5, min. 1-in thick polyisocyanurate composite foamed plastic insulation boards, nom. 48 by 48 or 96 in., with a facer on one side and wood fiber board on the other. WINDOWS AND LOUVERS: WIN-1: REMOVE EXISTING ALUMINUM WINDOW INCLUDING FRAME, GLASS, ALL ASSOCIATED INTERIOR AND EXTERIOR ALUMINUM TRIM AND SEALANTS. RMAX OPERATING L L C — "Thermasheath-SI" L-1: REMOVE EXISTING MECHANICAL LOUVER INCLUDING FRAME, ALL ASSOCIATED INTERIOR AND EXTERIOR TRIM AND SEALANTS. EXISTING OPENING TO BE PREPARED FOR INSTALLATION OF NEW 3-HR RATED WALL INFILL, REMOVE ALL MATERIALS NECESSARY FOR INSTALLATION OF NEW 3-HR CMU INFILL. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. 429 Michigan St. Toledo, Ohio C2 A1.11 1. REMOVE OR CUT EXISTING WINDOW, WALL ANCHORS AND SHIMS TO PROVIDE A CLEAN, CLEAR OPENING FOR NEW CONSTRUCTION. UL. #U904 Fire Resistance Specs SCALE: 1' = A Last Updated on 2015-05-26 ADDITIONAL NOTES FOR WINDOWS AND CURTAIN WALL: C FIRE SEALANT EXISTING WALL 1'-0" http://database.ul.com/cgi-bin/ulweb/LISEXT/1FRAME/FireResistanceWizard.html C 6/22/2015 7'-0" +/- FIELD VERIFY U FIRE SEALANT B FIRE SEALANT EXISTING WALL SEALANT WIN-1 WIN-1 Printed 6/23/2015 EXISTING STAIR TO REMAIN 05.12.2015 FINAL OWNER REVIEW A3 A1.11 1'-0" 5 4 SCALE: 3/4" = 1'-0" A2 A1.11 3 PLAN DETAIL SCALE: 3/4" = 1'-0" ARB APPROVED ARB ELEVATIONS & L 3" X 3" X 1/8" A ANCHORS @ 48" O.C. VERTICALLY PLAN DETAIL CHECKED ENLARGED PLANS, BUILDING PAPER BOND BREAKER BUILDING PAPER BOND BREAKER Partial North (Jackson Street) Exterior Elevation 6 PERMIT SHEET TITLE EXISTING MTL. STUD WALL TO REMAIN 12" NOMINAL CMU 3-HR RATED TO INFILL ROUGH OPENING EXISTING RAILING TO REMAIN 7 3'-4" +/- FIELD VERIFY 3'-6" +/- FIELD VERIFY ALL ROUGH OPENINGS TO BE IN-FILLED WITH 3 HOUR RATED CMU TYP. SCALE: 1/8" = 06.23.2015 TCI JOB NO. 160278 12" NOMINAL CMU, 3-HR FIRE RATED A4 A1.11 BIDDING B WIN-1 A 06.23.2015 A1 A1.11 2 SHEET NO. PLAN DETAIL SCALE: 3/4" = WALL TYPES A1.11 1'-0" 1 7 6 5 18 17 16 15 14 4 13 12A 12 11 10 3 9 8 7 6 2 5 4 3 1 2 1 F E F L L K K J J H H E KEY PLAN N N.T.S. D D G G F ELEV. PIT ELEV. E D C F PROJECT TITLE E Utilities and Building Separation D C C B B A A 18 17 16 15 14 13 12A 12 11 10 9 8 7 6 5 4 2 3 429 Michigan Street Toledo, OH C 1 B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED RFY APPROVED LS B TCI JOB NO. 160261 SHEET TITLE GROUND FLOOR PLAN FIRE PROTECTION A A SHEET NO. FP1.01 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687 7 6 5 4 3 2 1 F F E E PLAYGROUND KEY PLAN N N.T.S. D D CSI PROJECT TITLE Utilities and Building Separation 429 Michigan Street Toledo, OH FCC C C AREAWAY RAISED PLANTER AREA B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED RFY APPROVED LS B TCI JOB NO. 160261 SHEET TITLE PARTIAL SITE PLAN PLUMBING A A SHEET NO. P1.01 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687 7 6 5 18 17 16 15 14 4 13 12A 12 11 10 3 9 8 7 6 2 5 4 1 2 3 1 F F L L K K E E J J H H KEY PLAN G N.T.S. G D D F F ELEV. PIT ELEV. E D E PROJECT TITLE Utilities and Building Separation D C C 429 C N B B A A 18 17 16 15 14 13 12A 12 11 10 9 8 7 6 5 4 2 3 Michigan Street Toledo, OH C 1 B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED RFY APPROVED LS B TCI JOB NO. 160261 SHEET TITLE GROUND FLOOR PLAN PLUMBING A A SHEET NO. P1.02 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687 7 6 5 4 3 2 1 F F E E KEY PLAN N N.T.S. D D PROJECT TITLE Utilities and Building Separation 429 Michigan Street Toledo, OH C C B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED RFY APPROVED LS B TCI JOB NO. 160261 SHEET TITLE NOTES AND DETAILS PLUMBING A A SHEET NO. P2.01 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687 7 6 5 18 17 16 15 14 4 13 12A 12 11 10 3 9 8 7 6 2 5 4 1 2 3 1 F E F L L K K J J H H E KEY PLAN N N.T.S. D D G G F ELEV. PIT ELEV. E D C F PROJECT TITLE E Utilities and Building Separation D C C B B A A 18 17 16 15 14 13 12A 12 11 10 9 8 7 6 5 4 3 2 429 Michigan Street Toledo, OH C 1 B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED DRM APPROVED LJS B TCI JOB NO. 160261 SHEET TITLE MECHANICAL GROUND FLOOR PLAN A A SHEET NO. M1.01 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687 7 6 5 18 17 16 15 14 4 13 12A 12 11 10 3 9 8 7 6 2 5 4 1 2 3 1 F E F L L K K J J H H E KEY PLAN N N.T.S. D D G G F ELEV. ELEV. E D C F PROJECT TITLE E Utilities and Building Separation D ELEV. C C B B A A 18 17 16 15 14 13 12A 12 11 10 9 8 7 6 5 4 2 3 429 Michigan Street Toledo, OH C 1 B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED DRM APPROVED LJS B TCI JOB NO. 160261 SHEET TITLE MECHANICAL SECOND FLOOR PLAN A A SHEET NO. M1.02 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687 7 6 5 18 17 16 15 14 4 13 12A 12 11 10 3 9 8 7 6 2 5 4 1 2 3 1 F E F L L K K J J H H E KEY PLAN N N.T.S. D D G G F ELEV. ELEV. E D C F PROJECT TITLE E Utilities and Building Separation D ELEV. C C B B A A 18 17 16 15 14 13 12A 12 11 10 9 8 7 6 5 4 2 3 429 Michigan Street Toledo, OH C 1 B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED DRM APPROVED LJS B TCI JOB NO. 160261 SHEET TITLE MECHANICAL THIRD FLOOR PLAN A A SHEET NO. M1.03 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687 7 6 5 4 3 2 1 F F E E KEY PLAN N N.T.S. D D PROJECT TITLE Utilities and Building Separation 429 Michigan Street Toledo, OH C C B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED BAS APPROVED RJG B TCI JOB NO. 160261 SHEET TITLE A A ELECTRICAL SCHEDULES, LEGEND SPECIFICATIONS & ONE-LINE SHEET NO. E0.01 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687 7 6 5 18 17 16 15 14 4 13 12A 12 11 10 3 9 8 7 6 2 5 4 1 2 3 1 F E F L L K K J J H H E KEY PLAN N N.T.S. D D G G F ELEV. PIT ELEV. E D C F PROJECT TITLE E Utilities and Building Separation D C C B B A A 18 17 16 15 14 13 12A 12 11 10 9 8 7 6 5 4 2 3 429 Michigan Street Toledo, OH C 1 B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED BAS APPROVED RJG B TCI JOB NO. 160261 SHEET TITLE ELECTRICAL GROUND FLOOR PLAN - LIGHTING A A SHEET NO. E1.01 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687 7 6 5 18 17 16 15 14 4 13 12A 12 11 10 3 9 8 7 6 2 5 4 1 2 3 1 F E F L L K K J J H H E KEY PLAN N N.T.S. D D G G F ELEV. PIT ELEV. E D C F PROJECT TITLE E Utilities and Building Separation D C C B B A A 18 17 16 15 14 13 12A 12 11 10 9 8 7 6 5 4 2 3 429 Michigan Street Toledo, OH C 1 B 06-23-2015 FOR PERMIT 06-23-2015 FOR BIDDING 05-12-2015 FOR REVIEW CHECKED BAS APPROVED RJG B TCI JOB NO. 160261 SHEET TITLE ELECTRICAL GROUND FLOOR PLAN - POWER A A SHEET NO. E2.01 Mechanical and Electrical Engineers 7 6 5 4 3 2 1 1415 Holland Road Maumee, Ohio 43537 Phone: (419) 893-3141 Fax: (419) 893-0687