CRH-XHE 102÷904 Packaged air-conditioning unit 4Heat pump Water cooled Roof Top Capacity from 42,3 to 315 kW On Line Monitoring Service available GEOTHERMIC The CRH-XHE packaged air-conditioning units are installed outside the spaces being served. They come in various capacities and with a vast range of accessories. They are intended for the air-conditioning of large rooms or areas and are applied in closed or open loop water systems. Designed to reduce work on site to a minimum, these units have been created for continuous operation with maximum energy saving through an extremely intelligent, advanced management of energy, supplying it only when and where needed. They are extremely versatile units with three airflow settings: standard, high and reduced. The high efficiency of the innovative refrigeration circuit, optimized for functioning at partial loads, the free-cooling and the energy recovery of expelled air available as an option on the whole range, allow to reduce energy consumption and therefore the management costs and the emission of carbon dioxide. functions and features H2O Heating-Cooling Water cooled FC R-410A Roof Top Refrig. R-410A Herm. Scroll Free-Cooling EEV CC Direct Coupled Fan (102÷302) Electronic Expansion Valve available configurations (1) CRH-XHE C 402 (2) (3) (4) (5) (6) (7) M 200 R 100 SM SR (1) CONSTRUCTIONAL CONFIGURATION: 4B Fresh air mixing/recirculation plenum 4C Radial expulsion fan, mixing chamber /re-circulation / external air intake with free-cooling adjustment. (sizes 102÷302) With intake/discharge fan, mixing/recirculation plenum and fresh air return available with Free-Cooling control (sizes 362÷904) (2) SUPPLY: 4M Outflow (3) HEAD PRESSURE IN SUPPLY (4) RETURN: 4R Return (5) HEAD PRESSURE IN RETURN (sizes 362÷904 only) (6) SUPPLY AIR FLOW RATE: 4SM Standard air flow rate 4RM Reduced air flow rate 4HM High air flow rate (7) RETURN AIR FLOW RATE (sizes 362÷904 only): 4SR Standard air flow rate 4RR Reduced air flow rate 4HR High air flow rate accessories 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Anti-ice electric heater protection on the water side exchanger Thermal Free-Cooling Enthalpy Free-Cooling Enthalpy control (humidification, dehumidification, post-heating) High efficiency air filter F7 Extra section of very high efficiency electronic filters H10 Steel mesh filter on water side Plumbing assembly for loop with constant flow rate Plumbing assembly for loop with variable flow rate Plumbing assembly for system with disposable water High and low pressure gauges Uprated electric fan motors for static pressure values higher than standard (only sizes 362÷904) Air quality sensor for CO2 control Air quality sensor for CO2 and VOC control Air side dirty filters differential pressure switch Remote control with remote microprocessor control Serial communication module RS485 (LON WORKS) 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Serial communication module RS485 (MODBUS) Copper/copper evaporator coil Hot water coil with 2 rows Electric heating coil 3-way modulating valve Phase monitor Shunt capacitors (power factor > 0,9) Active energy recovery of expelled air Hot gas post-heating coil Constant supply air flow-rate (only sizes 102÷302) Immerse electrode steam humidifier Droplet-separator humidifier with once-through water Modulating fresh air outlet damper On/off motorized fresh air outlet damper Rubber antivibration mounts (only sizes 102÷302) Application with fabric ducts Rain cover with pre-filter (only sizes 464÷904) Device for fan inrush current reduction (sizes 362÷904) Key to symbols: Accessories supplied separately. technical data (1) kW (1) kW (1) kW (2) kW (2) kW (3) (4) Pa l/s (3) (4) Pa l/s (5) dB(A) V/Ph/Hz 102 42,3 33,2 7,54 44,6 7,63 122 48,7 37,7 9,20 52,3 9,38 182 66,7 49,5 12,2 71,6 13,5 222 76,2 56,2 14,6 83,3 16,0 2 262 302 94,1 104 70,1 78,2 16,7 18,9 103 115 18,4 20,9 SCROLL 1 RAD 2 RAD 450 520 450 370 460 510 2200 2500 3060 3610 4440 5000 60 62 64 65 66 67 362 121 90,1 22,0 134 24,1 402 452 464 524 604 704 804 904 136 147 162 184 211 239 285 315 99,7 109 122 139 158 177 216 236 24,8 28,1 28,0 33,2 37,9 43,8 50,0 56,7 153 168 179 205 232 267 312 344 28,2 32,0 31,3 37,6 41,1 49,2 53,1 59,9 4 SCROLL 1 CFG 300 210 210 300 210 330 300 330 270 5555 6111 6666 8056 9028 10000 11111 12500 13888 1 CFG 210 120 120 150 180 240 120 210 210 4444 4888 5333 6444 7222 8000 8889 10000 11111 69 70 71 72 73 73 73 74 75 400/3/50 Data referred to the following conditions: pressure is measured at 1 m from the external surface of the unit in open field conditions. Working static pressure 50 Pa. The above data refer to standard units. Constructional configuration B (1) (2) (3) (4) Ambient air at 27°C/19,5°C W.B.; external exchanger water = 29/35°C; operation at full re-circulation Ambient air at 20°C D.B.; water at exchanger outlet 10°C; operation at full re-circulation CFG = centrifugal fan; RAD = CC Radial-blade fan (Direct Coupled Fan) With electrical motors standard. For the units CRH-XHE 102-302, net pressure available to overcome supply and return pressure drops (5) Sound levels refer to A version standard units with full load under nominal test conditions. The sound dimensions and clearances C C A1 B1 B B1 A B2 A1 B B2 A CRH-XHE 362÷452 CRH-XHE 102÷302 Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) Weight in oper. mm mm mm mm mm mm mm Kg 102 2750 1780 1870 1500 1500 1500 1067 122 2750 1780 1870 1500 1500 1500 1117 182 2750 2180 1870 1500 1500 1500 1294 222 2750 2180 1870 1500 1500 1500 1344 262 2750 2180 2256 1500 1500 1500 1560 302 2750 2180 2256 1500 1500 1500 1610 362 3970 2180 2256 1500 1500 1500 2135 402 3970 2180 2256 1500 1500 1500 2205 452 3970 2180 2256 1500 1500 1500 2255 464 5416 2185 2272 1500 1500 1500 1500 2920 524 5416 2185 2272 1500 1500 1500 1500 3000 604 5416 2185 2272 1500 1500 1500 1500 3080 704 5416 2185 2272 1500 1500 1500 1500 3190 804 6602 2185 2272 1500 1500 1500 1500 4385 The above data refer to units in constructional configuration C. N.B. For all other constructional configurations, see the relevant Technical Bulletin. C A2 A B B1 CAUTION! CRH-XHE 464÷904 A1 For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas. Data contained in this document are not binding and may be changed by the Manufacturer without notice. No part of this publication may be reproduced. www.clivet.com 904 6602 2185 2272 1500 1500 1500 1500 4480 ext.DG09A001GB-00 GEOTHERMIC Sizes Cooling capacity 4 Sensible cooling capacity Compressor input Heating capacity 4 Compressor input Number and type of compressors Number and type of circulating fans Max. working static pressure for supply Distribution air flow rate Number and type of return fans Max. working static pressure for return Return air flow rate Sound pressure level Power supply