CRH-XHE (42kW

advertisement
CRH-XHE
102÷904
Packaged air-conditioning unit
4Heat pump
Water cooled
Roof Top
Capacity from 42,3 to 315 kW
On Line Monitoring Service available
GEOTHERMIC
The CRH-XHE packaged air-conditioning units are installed outside the
spaces being served. They come in various capacities and with a vast range
of accessories. They are intended for the air-conditioning of large rooms or
areas and are applied in closed or open loop water systems.
Designed to reduce work on site to a minimum, these units have been created
for continuous operation with maximum energy saving through an extremely
intelligent, advanced management of energy, supplying it only when and
where needed. They are extremely versatile units with three airflow settings:
standard, high and reduced.
The high efficiency of the innovative refrigeration circuit,
optimized for functioning at partial loads, the free-cooling and the energy
recovery of expelled air available as an option on the whole range, allow
to reduce energy consumption and therefore the management costs and the
emission of carbon dioxide.
functions and features
H2O
Heating-Cooling
Water cooled
FC
R-410A
Roof Top
Refrig. R-410A
Herm. Scroll
Free-Cooling
EEV
CC
Direct Coupled Fan
(102÷302)
Electronic Expansion
Valve
available configurations
(1)
CRH-XHE
C
402
(2)
(3)
(4)
(5)
(6)
(7)
M
200
R
100
SM
SR
(1) CONSTRUCTIONAL CONFIGURATION:
4B Fresh air mixing/recirculation plenum
4C Radial expulsion fan, mixing chamber /re-circulation /
external air intake with free-cooling adjustment. (sizes
102÷302)
With intake/discharge fan, mixing/recirculation plenum
and fresh air return available with Free-Cooling control
(sizes 362÷904)
(2) SUPPLY:
4M Outflow
(3) HEAD PRESSURE IN SUPPLY
(4) RETURN:
4R Return
(5) HEAD PRESSURE IN RETURN (sizes 362÷904 only)
(6)
SUPPLY AIR FLOW RATE:
4SM Standard air flow rate
4RM Reduced air flow rate
4HM High air flow rate
(7)
RETURN AIR FLOW RATE (sizes 362÷904 only):
4SR Standard air flow rate
4RR Reduced air flow rate
4HR High air flow rate
accessories
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Anti-ice electric heater protection on the water side exchanger
Thermal Free-Cooling
Enthalpy Free-Cooling
Enthalpy control (humidification, dehumidification, post-heating)
High efficiency air filter F7
Extra section of very high efficiency electronic filters H10
Steel mesh filter on water side
Plumbing assembly for loop with constant flow rate
Plumbing assembly for loop with variable flow rate
Plumbing assembly for system with disposable water
High and low pressure gauges
Uprated electric fan motors for static pressure values higher than
standard (only sizes 362÷904)
Air quality sensor for CO2 control
Air quality sensor for CO2 and VOC control
Air side dirty filters differential pressure switch
Remote control with remote microprocessor control
Serial communication module RS485 (LON WORKS)
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Serial communication module RS485 (MODBUS)
Copper/copper evaporator coil
Hot water coil with 2 rows
Electric heating coil
3-way modulating valve
Phase monitor
Shunt capacitors (power factor > 0,9)
Active energy recovery of expelled air
Hot gas post-heating coil
Constant supply air flow-rate (only sizes 102÷302)
Immerse electrode steam humidifier
Droplet-separator humidifier with once-through water
Modulating fresh air outlet damper
On/off motorized fresh air outlet damper
Rubber antivibration mounts (only sizes 102÷302)
Application with fabric ducts
Rain cover with pre-filter (only sizes 464÷904)
Device for fan inrush current reduction (sizes 362÷904)
Key to symbols:
Accessories supplied separately.
technical data
(1) kW
(1) kW
(1) kW
(2) kW
(2) kW
(3) (4) Pa
l/s
(3) (4) Pa
l/s
(5) dB(A)
V/Ph/Hz
102
42,3
33,2
7,54
44,6
7,63
122
48,7
37,7
9,20
52,3
9,38
182
66,7
49,5
12,2
71,6
13,5
222
76,2
56,2
14,6
83,3
16,0
2
262 302
94,1 104
70,1 78,2
16,7 18,9
103 115
18,4 20,9
SCROLL
1 RAD
2 RAD
450 520 450 370 460 510
2200 2500 3060 3610 4440 5000
60
62
64
65
66
67
362
121
90,1
22,0
134
24,1
402 452 464 524 604 704 804 904
136 147 162 184 211 239 285 315
99,7 109 122 139 158 177 216 236
24,8 28,1 28,0 33,2 37,9 43,8 50,0 56,7
153 168 179 205 232 267 312 344
28,2 32,0 31,3 37,6 41,1 49,2 53,1 59,9
4 SCROLL
1 CFG
300 210 210 300 210 330 300 330 270
5555 6111 6666 8056 9028 10000 11111 12500 13888
1 CFG
210 120 120 150 180 240 120 210 210
4444 4888 5333 6444 7222 8000 8889 10000 11111
69
70
71
72
73
73
73
74
75
400/3/50
Data referred to the following conditions:
pressure is measured at 1 m from the external surface of the unit in open field conditions. Working static
pressure 50 Pa. The above data refer to standard units. Constructional configuration B
(1) (2) (3)
(4)
Ambient air at 27°C/19,5°C W.B.; external exchanger water = 29/35°C; operation at full re-circulation
Ambient air at 20°C D.B.; water at exchanger outlet 10°C; operation at full re-circulation
CFG = centrifugal fan; RAD = CC Radial-blade fan (Direct Coupled Fan)
With electrical motors standard. For the units CRH-XHE 102-302, net pressure available to overcome supply
and return pressure drops
(5) Sound levels refer to A version standard units with full load under nominal test conditions. The sound
dimensions and clearances
C
C
A1
B1
B
B1
A
B2
A1
B
B2
A
CRH-XHE 362÷452
CRH-XHE 102÷302
Sizes
Length (A)
Width (B)
Height (C)
4(A1)
(A2)
(B1)
(B2)
Weight in oper.
mm
mm
mm
mm
mm
mm
mm
Kg
102
2750
1780
1870
1500
1500
1500
1067
122
2750
1780
1870
1500
1500
1500
1117
182
2750
2180
1870
1500
1500
1500
1294
222
2750
2180
1870
1500
1500
1500
1344
262
2750
2180
2256
1500
1500
1500
1560
302
2750
2180
2256
1500
1500
1500
1610
362
3970
2180
2256
1500
1500
1500
2135
402
3970
2180
2256
1500
1500
1500
2205
452
3970
2180
2256
1500
1500
1500
2255
464
5416
2185
2272
1500
1500
1500
1500
2920
524
5416
2185
2272
1500
1500
1500
1500
3000
604
5416
2185
2272
1500
1500
1500
1500
3080
704
5416
2185
2272
1500
1500
1500
1500
3190
804
6602
2185
2272
1500
1500
1500
1500
4385
The above data refer to units in constructional configuration C.
N.B. For all other constructional configurations, see the relevant Technical Bulletin.
C
A2
A
B
B1
CAUTION!
CRH-XHE 464÷904
A1
For trouble-free operation of the unit it is essential to maintain the safety
distances indicated by the green areas.
Data contained in this document are not binding and may be changed by the Manufacturer without notice. No part of this publication may be reproduced.
www.clivet.com
904
6602
2185
2272
1500
1500
1500
1500
4480
ext.DG09A001GB-00
GEOTHERMIC
Sizes
Cooling capacity
4
Sensible cooling capacity
Compressor input Heating capacity
4
Compressor input Number and type of compressors
Number and type of circulating fans
Max. working static pressure for supply
Distribution air flow rate
Number and type of return fans
Max. working static pressure for return
Return air flow rate
Sound pressure level
Power supply
Download