M Family Digital Machine Protection Relay 3 Three-phase protection for electrical machines. Features and Benefits Protection and Control ■ Advanced 16-bit microprocessor ■ Thermal image protection ■ Configurable logic, curves, digital I/Os and LEDs ■ Unbalance ■ Overcurrent and undercurrent ■ Flash memory for field upgrades ■ Monitoring and metering ■ Two settings groups ■ Analog/digital oscillography ■ Drawout case for easy maintenance ■ 24 event recording ■ AC/DC power supply ■ Restricted ground fault ■ Access via front panel keypad or communication links User Interfaces ■ Compatible with M Family systems in half or full 19" racks Applications ■ Protection and control for generators, motors, and transformers ■ enerVista.com compatible (see page 275) ■ M+PC software for setting and monitoring ■ Front RS232 and rear RS485 ports using ModBus® RTU protocol up to 19,200 bps GE Multilin 1 MIG M Family Digital Machine Protection Relay Protection The MIG Digital Machine Protection Relay is designed specifically for small generators and motors. As part of the M Family, the MIG provides superior protection which includes: 3 Thermal Image Unit The thermal image algorithm protects the machine from negative sequence components that can cause overheating in the stator and rotor, as well as overload. an additional ground sensor. Alternatively, for more sensitive detection, an additional core balance (zero sequence) ground sensor encircling the three-phase conductors can be used. Undercurrent Ground IOC Units Starts/Hour and Time To Restart This protection has the same settings and features as the phase IOC unit. This feature counts the number of machine starts during a time window to ensure they do not This function is used in motor applications to detect a decrease in machine current caused by load decrease. The unit can be set as an alarm or trip. Functional Block Diagrams Unbalance 52G Protection against rotor damage is provided through definite time or time curve models, to minimize heating caused by the negative sequence current generated by supply voltage unbalance. GENERATOR APPLICATION 49 46 51P 50P 50G 51G METERING OSCILLOGRAPHY EVENT RECORDING CONFIGURABLE I/O CONFIGURABLE LEDS CONFIGURABLE LOGIC GEN Three-Phase TOC This protection can be set from 0.1 to 2.4 times I n. Four separate ANSI or IEC TOC curves can be selected including definite time, normal inverse, very inverse, and extremely inverse. Additionally, a user configurable curve is available. Different time multipliers may be set for each curve, optimizing curve selection for coordination with fuses, machines, motors, transformers, or other equipment. ANSI IEC/BS142 normal inverse very inverse extremely inverse definite time IEC A IEC B IEC C definite time MIG Digital Machine Protection 3 Adjustable phase IOC allows the pickup setpoint to be set from 0.1 to 30 times I n and a time delay from 0 to 100 seconds. This feature has the same curve selection choices and settings as the phase TOC unit. The ground signal is normally derived as the residual sum of the three-phase CTs eliminating the need for 2 49 46 51P 50P 37 66 50G 51G METERING OSCILLOGRAPHY EVENT RECORDING CONFIGURABLE I/O CONFIGURABLE LEDS CONFIGURABLE LOGIC MIG M Phase IOC Units Ground TOC MOTOR APPLICATION 52M Digital Machine Protection 742751A2.ai 52 TRANSFORMER APPLICATION 49 3 46 51P METERING OSCILLOGRAPHY EVENT RECORDING CONFIGURABLE I/O CONFIGURABLE LEDS CONFIGURABLE LOGIC 50P 1 50G 51G 87R MIG 742752A2.ai www.GEindustrial.com/Multilin MIG M Family Digital Machine Protection Relay Locked Rotor The MIG provides protection during extra-long start-ups where excessive overcurrent conditions can damage rotors. This protection is critical for power applications where the motor drives the generator into service. Typical Wiring Note: Only for reference. For particular connections for any MIG model, please refer to its external connections drawing. ZERO SEQUENCE GROUND SENSING CONNECTION LINE A << B << >> C << >> >> 20 A MAX CIRCUIT BREAKER LOCATED BEFORE POWER INPUT ZERO SEQUENCE GROUND CT PHASE A CT PHASE C CT C1 C2 C3 C4 C5 C6 C7 C8 A1 A2 IB N IC N +/L -/N IA N IG N A6 CAUTION: Fork or ring terminals must be used on the termainal block. NOTE: Suitable disconnect devices (switch or circuit breaker) recommended located near the relay. OVERVOLTAGE CATEGORY: II (*) Terminals B12, A12 and B11 must be connected to SELV (safety extra-low voltage) parts (on the PLC). They are not to be tested for hipot test under any circumstance. (**) In basic model, inputs and outputs are configured as follows: OUTPUTS INPUTS OUT1: Phase Trip CC1: Disable 50P Function OUT2: Ground Trip CC2: Disable 50N Function OUT3: 50 Trip OUT4: 49 Alarm GROUND BUS Digital Generator Protection B5 B6 A8 CC1 A9 CC2 A10 COM RS232 SAFETY GND GROUND DIGITAL OUTPUTS(**) A5 DIGITAL INTPUTS(**) >> MIG TRIP << C1 C2 C3 C4 C5 C6 C7 C8 IA Internally fused 1A/250V fast blow RS485 52a TRIP COIL READY Restricted Ground Fault (RGF) protection provides sensitive ground fault detection for low magnitude fault currents that may not be detected by other protection functions. This protection is often applied to machines and transformers having impedance grounded wye windings. TRIP COIL CONTROL POWER + C N IB N IC N IG N POWER CURRENT INPUTS 52a B PHASE C CT NOTE: 14 AWG wiring recommended (2.5 mm2) AC or DC CIRCUIT BREAKER A PHASE B CT GE Multilin Restricted Ground Fault ALTERNATIVE CT WIRING FOR RESIDUAL GROUND SENSING PHASE A CT PHASE B CT CURRENT INPUTS SDA B12(*) A SDB A12(*) B GND B11(*) GROUND JX COM OUT4 OUT3 OUT1/2 OUT1 exceed the number programmed by the user. If the number is exceeded, the unit blocks any new attempts and keeps the trip contact closed during the restart block time. B7 INPUT B8 PROGRAMMABLE CONTROLLER B9 B10 A7 INPUT 742750A2.ai Inputs and Outputs The factory configuration of MIG inputs and outputs can be easily modified using M+PC software. Two digital inputs and six relay outputs are provided, four of them programmable. These configurable outputs can be assigned either to a set of pre-configured values, or to an OR/NOT combination of the same values. Ordering MIG P * * * E O 00 * 00 * MIG P A I 1 5 1 5 N MIG Guideform Specifications For an electronic version of the MIG guideform specifications, please visit: www.GEindustrial.com/ Multilin/specs, fax your request to 905-201-2098 or email to literature.multilin@indsys.ge.com. F H C S Digital machine protection relay Three-phase + ground relay ANSI curves IEC curves Phase CT In = 1A (pickup range: 0.1 – 2.4 A) Phase CT In = 5A (pickup range: 0.5 – 12 A) Ground CT In = 1A (pickup range: 0.1 – 2.4 A) Ground CT In = 5A (pickup range: 0.5 – 12 A) Sensitive ground CT In = 1 A (pickup range: 0.005 – 0.12 A) 24 – 48 VDC auxiliary voltage (range: 19 – 58 VDC) 110 – 250 VDC (range: 88 – 300 VDC) and 110 – 230 VAC (range: 88 – 264 VAC) Individual relay Mounted in an M+ system† † If relays are to be mounted in an M+ system, then either an M050 half 19” rack or M100 full 19” rack case must be ordered. The M050 and M100 racks are provided at no additional cost based on the number of relays ordered. Accessories B1315P1 Depth reducing collar, reduces the mounting depth by 63 mm enerVista enabled See page 275. www.enerVista.com www.GEindustrial.com/Multilin 3 3