LLT LLT FAMILY LED Recessed Lensed Troffer A full family of sustainable recessed lighting products using high performance frosted lenses for attractive interior lighting. ALL THE RIGHT CHOICES FS FLUSH STEEL FS, FA Flush steel door frame is standard with simple-to-operate cam latch mechanism. Lens is positioned flush to the housing for a smooth glow at the ceiling plane. Flush Lens FA FLUSH ALUMINUM Three color options LED board and driver replaceable from below Flush aluminum door offers a robust frame with spring loaded latching. Lens position is flush to the housing for a smooth glow at the ceiling plane. RA RA REGRESSED ALUMINUM Regressed Aluminum door places the refractor above the ceiling plane for an architectural, regressed appearance using an aluminum frame with spring loaded latching. Three door options hinge & latch from either side Regressed Lens A12F ACRYLIC PATTERN 12 Acrylic Pattern 12 frosted lens is both attractive and efficient. IC rating standard on all models A19F ACRYLIC PATTERN 19 Acrylic Pattern 19 .156" frosted refractor offers a high-end aesthetic. A12F A19F Four lumen packages LED COLOR OPTIONS Choice of two lens options Choice of Recessed (shown), Surface, or Cable Mount 1 2' x 4' 3500K (35) Neutral 4000K (40) White Product versatility is all about the right product for the application. LLT offers up to four lumen packages with appropriate output ranges for general ambient lighting in many types of architectural conditions. Lower lumen packages may be applied to low ceilings, corridors or low ambient light locations. Medium and high lumen packages trend towards standard general lighting. Very high lumen packages may be selected for high ceilings, high light level needs, retail or health care. Size 2 2' x 2' 3 1x4 2x2 2x4 2 Warm LUMEN PACKAGES THREE SIZES 1' x 4' 3000K (30) Performance LW ML Nominal Lumens 1950 2400 Efficacy up to 91 Lumens per Watt Nominal Lumens 2100 2500 Efficacy up to 95 Lumens per Watt Nominal Lumens 3900 4700 Efficacy up to 95 Lumens per Watt HL VL 3100 3800 3300 4000 DESIGNLIGHTS CONSORTIUM® QUALIFIED LLT products are DesignLights Consortium® (DLC) qualified and, as such, may be included in project specifications and utility rebate programs for energy efficient, sustainable lighting solutions. Please refer to the DLC website for specific product qualifications at www.designlights.org. 3 LLT FAMILY LED Recessed Lensed Troffer ENERGY CODE COMPLIANCE CONTROLS INTEGRATION LIGHTING EFFICACY As of October, 2013, each state must adopt, at minimum, the national energy code ASHRAE 90.1-2010. The code is aimed squarely at energy reduction and has a direct impact on lighting. States may choose to exceed the national requirement. Saving energy through lighting control is a primary strategy for lighting design and code compliance. LLT is compatible with a full range of controls including, but not limited to: (LUMENS PER WATT) Among other things, ASHRAE 90.1-2010 will reduce the amount of power that commercial installations can use for lighting; that is the watts per square foot, or Lighting Power Density, is reduced compared to prior national standards. It is also noteworthy that Daylight Harvesting requirements are expanded and applied to smaller spaces than prior versions of the national code. OCCUPANCY & VACANCY SENSORS ASHRAE 90.1-2010 must be applied both to new construction as well as modifications or additions of 10% or more. Therefore, the code will apply to a wide range of applications including retrofit. DAYLIGHT HARVESTING SENSORS ENERGY CODE COMPLIANCE LIGHTING UPGRADES — ASHRAE REQUIREMENTS ASHRAE 90.1-2010 POWER DENSITY HIGHLIGHTS ASHRAE 90.1-2010 requires alterations of 10% or more of a space to comply with LPD requirements. Occupancy Sensors automate lights to turn both on and off. Vacancy Sensors automate the lights off function only and require a manual on function. Continuous dimming with 0-10V control, high/low circuit daylighting, or on/off daylighting. ENERGY SAVINGS WALL SWITCHES Single circuit, multi circuit, or high/low circuiting within a fixture. Building 2010 Area Type LPD (W/ft 2) 90.1-2010 = New Construction and Upgrades Hospital 1.21 DIMMERS 0-10V continuous dimming via manual control. Dormitory 0.61 Hotel 1.00 RELAY PANELS & LARGER SYSTEMS School 0.99 Timers, Sweeps, Energy Management Systems, or simple Relay Panel Systems. Warehouse 0.66 Office 0.90 1 or 2 circuit wiHUBB wireless controls enabled option allow LLT products to integrate seamlessly into Hubbell's unique wireless peer-to-peer, self-healing wireless mesh control network. 2X2 PERFORMANCE COMPARISON Size 2x2 Source, Source Lumen 35K Type Package LED T8 ML (2) 17W 2520 1791 Watts 27 31 Initial Lumen Lumens/ Maint. Watt 93 58 80% 95% Avg. fc Max/ Min 32 24 2.2 2.1 Watts per Variance, Square LPD Foot , LPD 0.42 0.48 Order LLT with WIH option to ship with factory installed wiHUBB wireless remote module. Antenna is prewired and is placed into the fixture with a quick snap-in action. Requires no additional fixture wiring or electrical access. Must be commissioned and controlled using award-winning wiHUBB interfaces. 0 14% DRIVER OPTIONS Proper control interface is easy with our simple driver options. Operation, light delivery, and wiring are all compatible with a multitude of control strategies. 2X4 PERFORMANCE COMPARISON Size 2x4 4 Source, Source Lumen 35K Type Package LED T5 T8 ML (2) 28W (2) 28W 4693 3890 4415 Watts Initial Lum/W Lumen Maint. Avg. fc Max/ Min 51 62 60 92 63 74 80% 95% 95% 48 44 48 2.4 2.3 2.3 Watts /Sq Variance, Ft , LPD LPD 0.64 0.78 0.80 0 22% 25% Driver Definition Operation E Fixed Output On/Off Electronic Step Dimming Electronic Dimming High/Low, On/Off Continuous Dimming ESD ED Light Delivery One Light Level Two Light Levels Variable Light Levels Wiring Occupancy Daylight Sensor Harvesting Compatible Compatible 3 Wire (hot, neutral, ground) • • 4 Wire (2 hot, neutral, 1 ground) • • 5 Wire (hot, neutral, ground plus (2) 0-10V dimming wires) • • 5 LLT FAMILY LED Recessed Lensed Troffer COLUMBIA'S LED DEVELOPMENT STRATEGY MAXIMIZED EFFICACY • Best in class Lumens Per Watt (LPW) with a choice of lumen packages SUSTAINABILITY TRACEABILITY Hubbell Inc. established its Hubbell Sustainability Initiative (HSI) to achieve an ongoing culture of environmental responsibility with its employees, customers, suppliers, community, and industry by implementing educational programs and sustainable practices. Hubbell's vision is to be a recognized leader in conserving natural resources to sustain our environment. LLT embodies the HSI philosophy through environmentally responsible design. • Identify existing LED module easily and provide on-site performance verification LUMEN MAINTENANCE • Designed to a minimum L80, meaning 80% of initial lumens at 50,000 hour life COLOR CONSISTENCY • Color consistency within 3 steps (MacAdam Ellipse) within each fixture, from fixture-to-fixture, and throughout life • Exceeds LRC recommendations for visually complex scenes* • Mercury and lead free • Low energy and carbon footprint • 50,000 hour life • Manufactured from recyclable materials • Components easily replaceable at end of life • Easily upgradeable to capitalize on improvements in solid state technology Y 0.42 0.415 0.41 COST OF OWNERSHIP 0.405 0.40 3-Step MacAdam Ellipse 0.395 0.39 MODULAR REPLACEABILITY 0.385 4-Step MacAdam Ellipse 0.38 0.375 X 0.37 0.38 • Low initial and operating cost 0.39 0.40 0.41 0.42 0.43 • The ability to replace driver or LED board for upgrades or maintenance • No "throw away" fixtures 0.44 ORDERING GUIDE INDUSTRY STANDARDS LLT • Adherence to LM79, LM80, and TM21 • DesignLights Consortium® (DLC) qualified – MODEL LLT LED Lensed MAINTENANCE FRIENDLY Troffer • Below ceiling access of electrical components QUALITY – COLOR TEMP 30 3000K 35 3500K 40 4000K SIZE • Fixtures will not ship if they do not pass rigorous testing protocols EXAMPLE LLT22-35HLG-FSA12F-EU 14 1' x 4' 22 2' x 2' 24 2' x 4' LW ML HL VL CEILING TYPE G Grid1 SM Surface Mount CM Cable Mount2 For hard ceilings use flange kit accessory. SHIELDING A12F Pattern 12 Frosted Acrylic Lens A19F Pattern 19 Frosted Acrylic Lens .156" LUMEN OUTPUT DOOR Low Watt Medium Lumen High Lumen 1 Very High Lumen 1 FS White Flush Steel • Options for switching, dimming, daylighting, and occupancy sensors • wiHUBB enabled wireless control options ONGOING IMPROVEMENT • Multi-generational approach to state-of-the-art technology Aluminum3 RA White Developing Color Tolerance Criteria for White LEDs, Lighting Research Center, Rensselaer Polytechnic Institute Damp Label - standard. IC Rating - standard. 6 – VOLTAGE U 120V-277V ACCESSORIES (ORDER SEPARATELY) FK14 1' × 4' Flange Kit, Single FK22 FK24 FKCR CM 48Y1SC3F-KIT CM 48Y2SC3F-KIT Mounting (for rows add FKCR) 2' × 2' Flange Kit, Single Mounting (for rows add FKCR) 2' x 4' Flange Kit, Single Mounting (for rows add FKCR) Flange Kit Row Adaptor (All Sizes) 48" Cable Mount Kit for 1' wide Cable Mount fixtures, 3-Wire Feed Cord 48" Cable Mount Kit for 2' wide Cable Mount fixtures, 3-Wire Feed Cord For drywall order Flange Kit accessories separately. Order hanger accessories separately. 3 Standard with Spring Loaded Latches. 4 Can be converted to fixed output by tying hot leads together. 5 For compatibility with Dual-Lite LiteGear® inverters in lieu of installed battery pack, contact Hubbell Lighting representative. 6 In-Fixture Module Antenna adds 2" to overall fixture height at power feed location. 7 Not available with Surface Mount ceiling types. 1 2 * DRIVER E Fixed Output ESD Step Dimming4 ED 0-10V Dimming FA White Flush Regressed Aluminum3 For more door options contact factory. CONTROLS COMPATIBLE U – OPTIONS C388 C488 C588 ELL14 PAF SLL 4TB G1 G2 G3 GLR NYC WIH 3-Wire Flex 4-Wire Flex 5-Wire Flex Emergency Battery Pack Installed, 1400 Lumens5 Paint After Fabrication Spring Loaded Latches Four T-Bar Clips (1x4, 2x2 only) Sinlge Gasket (door to housing) Double Gasketing (G1 and lens to door) Triple Gasketing (G2 and housing to ceiling) Fast Blow Fuse NYC Compliant wiHUBB6,7 Product Availability — Nominal Lumens Size 1' x 4' LW ML HL VL 1950 2400 3100 3800 3300 4000 2' x 2' 2100 2500 2' x 4' 3900 4700 7 ALERA LIGHTING ARCHITECTURAL AREA LIGHTING BEACON PRODUCTS COLUMBIA LIGHTING COMPASS DEVINE LIGHTING HUBBELL BUILDING AUTOMATION HUBBELL INDUSTRIAL LIGHTING HUBBELL OUTDOOR LIGHTING KIM LIGHTING KURT VERSEN LITECONTROL PRESCOLITE PROGRESS LIGHTING SPAULDING LIGHTING SPORTSLITER SOLUTIONS STERNER WHITEWAY 701 Millennium Blvd. Greenville, SC 29607 Tel 864.678.1000 Fax 866.898.0131 www.columbialighting.com CO1067 1/14 Copyright © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. All rights reserved. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice.