16555 East Gale Avenue City of Industry, CA 91745 626.968.5666 www.aal.net TM Y-LED Upgrade Kit Installation Guide Fixture: SLVT - LARGENT ! WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. MAINTENANCE: A regularly scheduled maintenance program should be established to retain optimum light output and reduce heat retention. Dusting with a soft, clean, dry cloth is normally sufficient for the optics. CAUTION: All wiring must be done by a qualified electrician. KEEP THIS SHEET FOR FUTURE REFERENCE. UPGRADE KIT CONTENTS 1 2 UPGRADE KIT CONTENTS ITEM # PART # QTY DESCRIPTION 1 93049910 1 RETROFIT KIT Y-LED SLVT 2 A84005 2 8-32 WINGNUT PAGE 1/5 93049909 REV. A ARCHITECTURAL AREA LIGHTING 16555 East Gale Avenue City of Industry, CA 91745 626.968.5666 www.aal.net TM Y-LED Upgrade Kit Installation Guide Fixture: SLVT - LARGENT 1. ! REMOVE TOP COVER TURN OFF ALL POWER TO THE UNIT AND TAKE PROPER SAFETY PRECAUTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS PERSONAL INJURY. TOP COVER 1. REMOVE TOP COVER BY LOOSENING FOUR (4) 1/4-20 X 2" SCREWS. (FIG. 1-1) 1/4-20 X 2" SCREWS 4X A FIG. 1-1 DETAIL A PAGE 2/5 93049909 REV. A ARCHITECTURAL AREA LIGHTING 16555 East Gale Avenue City of Industry, CA 91745 626.968.5666 www.aal.net TM Y-LED Upgrade Kit Installation Guide Fixture: SLVT - LARGENT 2. REMOVE EXISTING REFLECTOR ASSEMBLY AND HID COMPONENTS. 1. DISENGAGE QUICK-DISCONNECT AND PULL APART. (FIG. 2-1) 2. REMOVE REFLECTOR BY REMOVING TWO 8-32 WINGNUTS. DO NOT DISCARD WINGNUTS.(FIG. 2-1) REFLECTOR ASSEMBLY 8-32 WINGNUT 2X QUICKDISCONNECT 3. REMOVE BALLAST BY REMOVING 2X 1/4-20 SCREWS. LOOSEN 8-32 SCREW AND REMOVE IGNITOR AND CAPACITOR. DRILL RIVETS OUT AND REMOVE CAPACITOR BRACKET. (FIG 2-2) 4. DISCONNECT ALL WIRE CONECTIONS. RIVETS 2X 8-32 SCREW IGNITOR AND CAPACITOR BALLAST 1/4-20 SCREWS 2X CAPACITOR BRACKET FIG 2-2 PAGE 3/5 93049909 REV. A ARCHITECTURAL AREA LIGHTING FIG2-1 16555 East Gale Avenue City of Industry, CA 91745 626.968.5666 www.aal.net TM Y-LED Upgrade Kit Installation Guide Fixture: SLVT - LARGENT 3. INSTALLING Y-LED MODULE 1. LINE UP Y-LED MODULE ASSY CARRIER PLATE HOLES OVER SCREWS, SECURE MODULE TO HOUSING WITH TWO WINGNUTS. (FIG. 3-1) 2. USING EXISTING HARDWARE BOND RING TERMINAL TO HOUSING. (FIG. 3-1) 3. CONNECT QUICK-DISCONNECT. IF REQUIRED, ATTACH PROVIDED FEMALE QUICK-DISCONNECT WIRE HARNESS USING PROVIDED CRIMP CONNECTORS. (FIG. 3-1) 4. MAKE ALL WIRE CONNECTIONS. Y-LED MODULE ASSEMBLY 8-32 WINGNUT 2X QUICKDISCONNECT FEMALE QUICKDISCONNECT HARNESS CRIMP CONNECTOR GROUND QUICKDISCONNECT RING TERMINAL FIG 3-1 PAGE 4/5 93049909 REV. A ARCHITECTURAL AREA LIGHTING 16555 East Gale Avenue City of Industry, CA 91745 626.968.5666 www.aal.net TM Y-LED Upgrade Kit Installation Guide Fixture: SLVT - LARGENT 4. INSTALLING TOP COVER TOP COVER 1. RETURN TOP COVER TO ITS ORIGINAL POSITION AND SECURE WITH (4) 1/4-20 SCREWS. (FIG. 4-1) 2. INSTALLATION COMPLETE. 1/4-20 X 2" SCREWS 4X FIG. 4-1 PAGE 5/5 93049909 REV. A ARCHITECTURAL AREA LIGHTING CATALOG NUMBER INSTALLATION INSTRUCTIONS SLVT-LED (MICROCORE) TOP CLOSURE COVER ASSEMBLY (4) DRIVERS EMITTER DECK HOUSING (4) CAPTIVE SCREWS FIXTURE INSTALLATION STEPS: 1) TURN POWER OFF. 2) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y. (NOTE: FIXTURE ASSEMBLY MUST BE GROUNDED TO INCOMING EQUIPMENT GROUND SUPPLY). 3) SLIP-FITTER OVER TOP OF POLE. SECURE FITTER WITH (3) STAINLESS STEEL SET SCREWS. 4) INSTALLATION COMPLETE. (3) STAINLESS STEEL SET SCREWS TO SERVICE EMITTER DECK/DRIVER: 1) TURN OFF POWER. 2) LOOSEN (4) CAPTIVE SCREWS LOCATED AT THE BOTTOM OF THE FIXTURE AND OPEN TOP CLOSURE COVER ASSEMBLY. 3) INTERIOR OF THE HOUSING IS EXPOSED. 4) SERVICE EMITTER AND DRIVERS AS NEEDED. 5) TO RE-ASSEMBLE REVERSE PROCEDURE. 16555 East Gale Avenue City of Industry, CA 91716-0080 (626)968-5666 Fax(626)330-3861 FITTER WIRE CONNECTORS (BY OTHERS) 4" O.D. POLE OR 4" O.D. ARM TOP TENON DATE 07/02/13 DATE 07/02/13 APPRVD PART NO. KC REV. A 93046553 CATALOG NUMBER INSTALLATION INSTRUCTIONS SLVT H* / CF TOP CLOSURE COVER ASSEMBLY (4) CAPTIVE SCREW LAMP (BY OTHERS) (REF) DOOR SCREW DOOR ASSEMBLY (3) STAINLESS STEEL SET SCREW FIXTURE INSTALLATION STEPS: 1) TURN POWER OFF. 2) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y. (NOTE: FIXTURE ASSEMBLY MUST BE GROUNDED TO INCOMING EQUIPMENT GROUND SUPPLY). 3) SLIP FITTER OVER TOP OF POLE. SECURE FITTER WITH (3) STAINLESS STEEL SET SCREWS. 4) INSTALLATION COMPLETE. FITTER WIRE CONNECTORS (BY OTHERS) LAMP INSTALLATION STEPS: 1) TURN OFF POWER. 2) LOOSEN DOOR SCREW FROM DOOR ASSEMBLY. 3) OPEN DOOR ASSEMBLY. 4) INSTALL LAMP (BY OTHERS). 5) CLOSE DOOR ASSEMBLY AND SECURE WITH DOOR SCREW. 6) INSTALLATION COMPLETE. 4" O.D. POLE OR 4" O.D. ARM TOP TENON TO SERVICE BALLAST: 1) TURN OFF POWER. 2) LOOSEN (4) CAPTIVE SCREWS LOCATED AT THE BOTTOM OF THE FIXTURE. OPEN TOP CLOSURE COVER ASSEMBLY AND SET ASIDE. 3) INTERIOR OF THE HOUSING IS EXPOSED. 4) DISCONNECT WIRE CONNECTORS. 5) SERVICE BALLAST AS NEEDED. 6) TO RE-ASSEMBLE, REVERSE PROCEDURE. 16555 East Gale Avenue City of Industry, CA 91745 (626)968-5666 DATE APPRVD PART NO. 8/13/2010 DATE REV. A96496 CATALOG NUMBER INSTALLATION INSTRUCTIONS SLVTL & SLVTLDL TOP CLOSURE COVER ASSEMBLY BALLAST COVER PLATE COVER PLATE (2) WING NUT SCREW (4) CAPTIVE SCREW (2) HEX KEP NUT FIXTURE INSTALLATION STEPS: 1) TURN POWER OFF. 2) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y. (NOTE: FIXTURE ASSEMBLY MUST BE GROUNDED TO INCOMING EQUIPMENT GROUND SUPPLY). 3) SLIP FITTER OVER TOP OF POLE. SECURE FITTER WITH (3) STAINLESS STEEL SET SCREWS. 4) INSTALLATION COMPLETE. LAMP (BY OTHERS) LAMP INSTALLATION STEPS: 1) TURN OFF POWER. 2) LOOSEN (4) CAPTIVE SCREWS LOCATED AT THE BOTTOM OF THE FIXTURE AND OPEN TOP CLOSURE COVER ASSEMBLY AND SET ASIDE. 3) INTERIOR OF THE HOUSING IS EXPOSE. 4) REMOVE (2) WING NUTS AND COVER PLATE. 5) INSTALL LAMP (BY OTHERS). 6) TO RE-ASSEMBLE, REVERSE PROCEDURE. (3) STAINLESS STEEL SET SCREW FITTER TO SERVICE BALLAST: 1) TURN OFF POWER. 2) LOOSEN (4) CAPTIVE SCREWS LOCATED AT THE BOTTOM OF THE FIXTURE AND OPEN TOP CLOSURE COVER ASSEMBLY AND SET ASIDE. 3) INTERIOR OF THE HOUSING IS EXPOSED. 4) REMOVE SCREW AND (2) HEX KEP NUTS. 5) LIFT BALLAST COVER PLATE. TURN UPSIDE DOWN AND DISCONNECT WIRE CONNECTORS. 6) SERVICE BALLAST AS NEEDED. 7) TO RE-ASSEMBLE, REVERSE PROCEDURE. 16555 East Gale Avenue City of Industry, CA 91745 (626)968-5666 WIRE CONNECTORS (BY OTHERS) 4" O.D. POLE OR 4" O.D. ARM TOP TENON DATE DATE NOTE: DRAWING SHOWN SLVTLDL OPTION. APPRVD PART NO. REV. A96497