Technical Data PanelView Component Specifications Catalog Numbers 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T4T, 2711C-T6M, 2711C-T6T, 2711C-T10C Topic Page Environmental Specifications 2 General Specifications 3 Certifications 3 Technical Specifications 4 Dimensions 6 Accessories 8 Software 9 Cables 10 Additional Resources 11 PanelView Component Family This component-level operator interface provides a control and visualization solution for low-level applications that use serial or Ethernet communication. This device can connect directly to the PowerFlex® 4 drives. Preferred controllers include the Allen-Bradley® MicroLogix™ and Micro800™ families. The integrated mounting clamps and quick-lever clips provide for panel installation and maintenance. These 2-inch to 10-inch displays have built-in programming software that is accessed from a web browser over a USB or Ethernet connection. You can design your application and adjust terminal settings while viewing the results directly on the connected terminal. Secured programming access, unicode language switching, alarm messages and history, and recipe operations are other key features. PanelView Component Specifications Environmental Specifications 2 Attribute 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T4T, 2711C-T6M, 2711C-T6T, 2711C-T10C Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): 0…50 °C (32…122 °F) Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -25…70 °C (-13…158 °F) Temperature, surrounding, max 50 °C (122 °F) Heat dissipation C200/C300: 16 BTU/hr C400: 24 BTU/hr C600: 32 BTU/hr C1000: 58 BTU/hr Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5…95% noncondensing Vibration IEC 60068-2-6 (Test Fc, Operating): 2 g at 10…500 Hz Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock): 15 g at 11 ms Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock): 30 g Emissions CISPR 11: Group 1, Class A ESD immunity IEC 61000-4-2: 4 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 3V/m with 1 kHz sine-wave 80% AM from 1400…2000 MHz 1V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz EFT/B immunity IEC 61000-4-4: ±2 kV at 5 kHz on power ports ±1 kV at 5 kHz on communication ports Surge transient immunity IEC 61000-4-5: ±500V line-line (DM) and ±1 kV line-earth (CM) on DC power ports ±1 kV line-earth (CM) on communication ports Conducted RF immunity IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 PanelView Component Specifications General Specifications Attribute 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T4T, 2711C-T6M, 2711C-T6T, 2711C-T10C Isolation voltage For 2711C-T4T only 30V (continuous), basic insulation type Tested at 500V for 60 s, line to Ethernet No isolation between all ports to line, except Ethernet port Duration indicates that the product was qualification or type-tested to the specified level (one-time tested on a representative sample) Wire size Single-wire gauge: 0.33…2.08 mm2 (22...14 AWG) Dual-wire gauge: 0.33…1.31 mm2 (22…16 AWG) Earth wire: 2.08…3.31 mm2 (14…12 AWG) Wire type Solid or stranded copper wire that is rated at 90 °C (194 °F), or greater Wiring category(1) 2 – on power ports 2 – on communication ports Enclosure type ratings Meets NEMA / UL Type 4X (indoor) 12, 13, and IEC IP54, IP65 (when marked) C600 series B only: NEMA / UL Type 12, 13, and IEC IP54 North American temperature code T3C – only for 2711C-T4T (1) Use this conductor category information to plan for conductor routing. See Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Certifications Certifications (when product is marked) (1) 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T4T, 2711C-T6M, 2711C-T6T, 2711C-T10C cULus UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E113724. Only for 2711C-T4T UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E10314. CE European Union 2004/108/EC EMC Directive, in compliance with: EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EAC Russian Customs Union TR CU 020/2011 EMC Technical Regulation RCM Australian Radiocommunications Act, in compliance with: AS/NZS CISPR 11; Industrial Emissions KC Korean Registration of Broadcasting and Communications Equipment, in compliance with: Article 58-2 of Radio Waves Act, Clause 3 (1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 3 PanelView Component Specifications Technical Specifications The tables in this section provide technical specifications for the PanelView™ Component terminals. Table 1 - Technical Specifications - PanelView Component C200 and C300 Terminals C200 2711C-F2M Attribute C200 2711C-K2M C300 2711C-T3M C300 2711C-K3M Display type Monochrome transflective STN passive matrix Monochrome transflective FSTN passive matrix Display size 2-in. 3-in. Display area (WxH) 49 x 14 mm (1.93 x 0.55 in.) 67 x 33 mm (2.64 x 1.30 in.) Resolution 122 x 32 128 x 64 Backlight 50,000 hours life, min; not replaceable 50,000 hours life, min; not replaceable Yellow/Green status indicator White status indicator Operator input Four function keys (F1…F4) Up, down, left, right, Enter keys Real-time clock No battery backup Battery 5-year min at 25 °C (77 °F) Programming port USB device port Communication ports RS-232 (DH-485), RS-232 (DF1), RS-485 Multi-vendor communication available for Modbus and Siemens MPI devices Memory card USB flash drive Software DesignStation software, version 2.0 or later Web-enabled software resident in terminal that is accessed through web browser Browser support: Firefox 3.0, Internet Explorer 7 or 8 Emulator available Preferred controller MicroLogix, SLC™, and Micro800 controllers Input voltage, DC 18…30V DC (24V DC nom) Power consumption, DC 5 W max (0.21 A at 24V DC) Weight, approx 0.19 g (0.40 lb) 0.30 kg (0.65 lb) 0.20 kg (0.43 lb) 0.30 kg (0.65 lb) Dimensions (HxWxD), approx 80 x 116 x 54 mm 3.15 x 4.54 x 2.13 in. 119 x 139 x 55 mm 4.69 x 5.47 x 2.15 in. 80 x 116 x 57 mm 3.15 x 4.54 x 2.23 in. 119 x 139 x 55 mm 4.69 x 5.47 x 2.15 in. Cutout dimensions (HxWxD), approx 65 x 100 mm 2.56 x 3.94 in. 100 x 120 mm 3.94 x 4.72 in. 65 x 100 mm 2.56 x 3.94 in. 100 x 120 mm 3.94 x 4.72 in. 4 Ten function keys (F1…F10) Numeric keypad 0…9 Up, down, left, right, decimal, +/-, Enter keys Analog touch Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 Ten function keys (F1…F10) Numeric keypad 0…9 Up, down, left, right, decimal, +/-, Enter keys PanelView Component Specifications Table 2 - Technical Specifications - PanelView Component C400, C600, and C1000 Terminals C400 2711C-T4T Attribute Display type C600 2711C-T6T Color transmissive TFT active matrix LCD Color transmissive TFT active matrix LCD C600 2711C-T6M Monochrome transmissive FSTN passive matrix C1000 2711C-T10C Color transmissive TFT active matrix LCD Display size 4.3-in. 5.7-in. 10.4-in. Display area (WxH) 95 x 53.86 mm (3.74 x 2.12 in.) 115 x 86 mm (4.53 x 3.39 in.) 211 x 158 mm (8.31 x 6.22 in.) Resolution 480 x 272 320 x 240 640 x 480 Backlight 40,000 hours life, min; not replaceable Operator input Analog touch Actuation rating: 1 million presses Real-time clock Battery backup Battery life 5-year min at 25 °C (77 °F) Programming port USB device port or Ethernet port Communication ports RS-232 (DH-485), RS-232 (DF1), RS-485, Ethernet Multi-vendor communication available for Modbus, Modbus/TCP, and Siemens MPI devices Memory card USB flash drive Software DesignStation software, version 2.0 or later Web-enabled software resident in terminal that is accessed through web browser Browser support: Firefox 3.0, Internet Explorer 7 or 8 Emulator available Preferred controller MicroLogix, SLC, and Micro800 controllers White status backlight 50,000 hours life, min; not replaceable White status backlight CCFL USB flash drive Secure Digital (SD) card: Cat. no. 2711C-RCSD, USB to SD adapter with SD card Input voltage, DC 18…30V DC (24V DC nom) 18…30V DC (24V DC nom) Power consumption, DC 3.5 W max (0.14 A at 24V DC) 10 W max (0.42 A at 24V DC) 18 W max (0.75 A at 24V DC) Weight, approx 0.35 g (0.76 lb) 0.68 g (1.48 lb) 1.57 kg (3.41 lb) Dimensions (HxWxD), approx 113 x 138x 43 mm 4.45 x 5.43 x 1.69 in. 154 x 209 x 57 mm 6.0 x 8.23 x 2.25 in. 250 x 308 x 54 mm 9.84 x 12.13 x 2.13 in. Cutout dimensions (HxWxD), approx 99 x 119 mm 3.9 x 4.69 in. 136 x 190 mm 5.35 x 7.48 in. 232 x 290 mm 9.13 x 11.42 in. Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 5 PanelView Component Specifications Dimensions Dimensions are provided for the PanelView Component terminals. Figure 1 - PanelView Component C200 and C300 Terminals c d a F1 1 F2 2 F3 3 F4 4 F5 5 F6 6 F7 7 F8 8 F9 9 F10 0 b Figure 2 - PanelView Component C200 Function Key and C300 Touch Terminals c d a F1 F2 F3 F4 b Table 3 - Dimensions - PanelView Component C200 and C300 Height, approx Width, approx Depth Overall, approx Mounted Depth, approx Cutout Height, approx Cutout Width, approx a b c d mm (in.) mm (in.) C200 and C300 Keypad 119 mm (4.69 in.) 139 mm (5.47 in.) 55 mm (2.15 in.) 49 mm (1.93 in.) 99.0 ± 1.0 (3.90 ± 0.04) 119.0 ± 1.0 (4.69 ±0.04) C200 Function Key 80 mm (3.15 in.) 116 mm (4.57 in.) 54 mm (2.13 in.) 49 mm (1.93 in.) 64.0 ± 1.0 (2.52 ± 0.04) 99.0 ± 1.0 (3.90 ±0.04) 64.0 ± 1.0 (2.52 ± 0.04) 99.0 ± 1.0 (3.90 ±0.04) PanelView Component C300 Touch 6 57 mm (2.23 in.) Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 PanelView Component Specifications Figure 3 - PanelView Component C400 Touch Terminal c d a b Figure 4 - PanelView Component C600 Touch Terminal c d PanelView C600 a b Figure 5 - PanelView Component C1000 Touch Terminal c d PanelView C1000 6 a 6 b Table 4 - Dimensions - PanelView Component C400, C600, and C1000 Height, approx Width, approx Depth Overall, approx Mounted Depth, approx Cutout Height, approx Cutout Width, approx a b c d mm (in.) mm (in.) C400 Touch 113 mm (4.45 in.) 138 mm (5.43 in.) 43 mm (1.69 in.) 38 mm (1.49 in.) 99.0 ± 1.0 (3.90 ± 0.04) 119.0 ± 1.0 (4.69 ±0.04) C600 Touch 154 mm (6.0 in.) 209 mm (8.23 in.) 57 mm (2.25 in.) 49 mm (1.93 in.) 135.0 ± 1.0 (5.31 ± 0.04) 189.0 ± 1.0 (7.44 ±0.04) C1000 Touch 250 mm (9.84 in.) 308 mm (12.13 in.) 54 mm (2.13 in.) 49 mm (1.93 in.) 231.0 ± 1.0 (9.09 ± 0.04) 289.0 ± 1.0 (11.38 ±0.04) PanelView Component Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 7 PanelView Component Specifications Accessories Table 5 through Table 8 list the accessories for the PanelView Component terminals. Table 5 - SD Card Cat. No. Description 2711C-RCSD USB to SD adapter with SD card Table 6 - Antiglare Overlays Cat. No.(1) Input Type PanelView Component Function Key C200 2711C-RG2F Numeric Keypad Touch • C300 2711C-RG2K • C200 • C300 • 2711C-RG6T C600 • 2711C-RG10T C1000 • (1) Three overlays are shipped with each catalog number. Table 7 - Power Terminal Blocks Cat. No. Description Quantity 2711C-RJ422 RS-422/485 connector with resistor 10 2711-TBDC DC power terminal block 10 Table 8 - Power Supply 8 Cat. No. Description Quantity 2711P-RSACDIN DIN-rail mount AC-to-DC power supply, 85…265V AC, 47…63 Hz 1 Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 PanelView Component Specifications Software The PanelView Component operator interface with its on-terminal programming software removes the need to install software on a personal computer and reduces both start-up and service time. Connect your computer to the PanelView Component terminal through a USB cable or Ethernet, then launch the software through your web browser. Microsoft Internet Explorer and Mozilla Firefox are supported. A dashboard provides one point of entry for accessing all terminal and design operations. Take advantage of these features while connected to the terminal: • Launch the design environment where navigation tabs guide you through application development. • View the results of your design efforts directly on the terminal without having to download the application first. • Modify terminal display and communication settings, view system information, and enable login security. • Transfer files between PanelView Component terminal storage and a USB flash drive, SD card, or computer; and delete files from terminal storage. • Change the start-up application or language the terminal uses for configuration screens and diagnostic messages. For programming without a PanelView Component, you can create an application using the free DesignStation software or an emulator. The emulator and browser must be on the same computer. Table 9 - Supported Browsers and Platforms Operating System Browser Platform Supported Windows 7 Windows Vista Windows XP, Service Pack 2 (SP2) Internet Explorer 7 and 8, Firefox 3.0 Terminal and emulator Internet Explorer 7 and 8 DesignStation 2.0 or later Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 9 PanelView Component Specifications Cables Use these cables for connecting PanelView Component terminals. Table 10 - Cables for PanelView Component Terminals Cat. No. Description For Use with These Terminals 2711C-CBL-UU02 USB-A host to USB-B device cable, 2 m (6.5 ft) C200, C300, C400, C600, and C1000 2711P-CBL-EX04 Ethernet crossover CAT5 cable, 4.3 m (14 ft) C400, C600, and C100 2711C-RCSD USB to SD adapter with SD card C200, C300, C400, C600, and C1000 1747-CP3 Serial 9-pin D-shell to 9-pin D-shell null modem cable, 3 m (10 ft) C200, C300, C400, C600, and C1000 1761-CBL-PM02 Serial 9-pin D-shell to 8-pin mini DIN cable, 2 m (6.5 ft) C200, C300, C400, C600, and C1000 2711C-CBL-AB03 RS-485 5-pin connector to RJ45 cable C200, C300, C600, and C1000 This table provides a summary of connections to MicroLogix controllers. Table 11 - PanelView Component Terminal Connections to MicroLogix Controllers Protocol PanelView Component Port MicroLogix (8-pin Mini DIN) 1000, 1100, 1400, 1200LSP, 1500LSP (CH0) MicroLogix (9-pin D-shell) 1500LRP (CH1) MicroLogix 1100/1400 RS-485 (1763-NC01) MicroLogix 1100, 1400 Ethernet DF1 RS-232 1761-CBL-PM002 1747-CP3 1747-CP3 — RS-232 1761-CBL-PM002 1747-CP3 1747-CP3 — DH-485 RS-485(1) — — — — Modbus RS-232 1761-CBL-PM002 1747-CP3 1747-CP3 — Ethernet (MicroLogix/ENI)2 Ethernet — — — CAT5 Ethernet (1) RS-485 is nonisolated and is recommended for connecting to only one device with an isolated port. 10 Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 PanelView Component Specifications Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Description PanelView Component Installation Instructions, publication 2711C-IN001 Provides instructions for installing a PanelView Component terminal. PanelView Component User Manual, publication 2711C-UM001 Provides information on how to configure and operate the PanelView Component terminal, including troubleshooting information. PanelView Component Quick Start, publication 2711C-QS001 Provides instructions on configuring a sample application on a PanelView Component terminal. Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing an automation industrial system. Product Certifications website, http://www.ab.com Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. Rockwell Automation Publication 2711C-TD001E-EN-P - July 2015 11 Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, MicroLogix, SLC, PowerFlex, Micro800, PanelView, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 2711C-TD001E-EN-P - July 2015 Supersedes Publication 2711C-TD001D-EN-P - January 2015 Copyright © 2015 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.