Data sheet CDR Cable Distribution Racks Item number Descriptive Code Description 84311972 CDR09-BKPD-00-TLPT-A 84313716 CDR09-BKPD-00-BLPT-A 84313718 CDR06-BKPD-1B-TL-30XX30-A 84313720 CDR06-BKPD-1B-BL-30XX30-A 900mm wide CDR, perforated doors, no conduit, top and bottom brush strips, top entry, top patch exit, bottom patch channel, 81 tray positions, Black (RAL 9005), tray units for MTP and Miniflex 900mm wide CDR, perforated doors, no conduit, top and bottom brush strips, bottom entry, bottom patch exit, top patch channel, 81 tray positions, Black (RAL 9005), tray units for MTP and Miniflex 600mm wide CDR, perforated door, 1 conduit per tray position, #1 at bottom, top and bottom brush strips, top entry, top patch exit, 60 tray positions separated by 2 x-connects, Black (RAL 9005), tray units for MTP and Miniflex 600mm wide CDR, perforated door, 1 conduit per tray position, #1 at bottom, top and bottom brush strips, bottom entry, bottom patch exit, 60 tray positions separated by 2 x-connects, Black (RAL 9005), tray units for MTP and Miniflex Created by: Doc. No.: Rev.: DW CDR_900_600_DW_01 B hubersuhner.com Data sheet CDR Cable Distribution Racks Page 2 of 6 Highest packing density for evolving data centres The CDR (Cable Distribution Rack) is a purpose-built high density fibre management rack which serves as a central cross-connect in the main distribution area of data centres. With a footprint depth of only 300 mm, the CDR is fully modular and scalable up to 1620 ports (3240 fibres) using LC connectivity. Users can benefit from a C-shaped construction where all internal sub-elements are completely installable and accessible from the front side. This important feature means that CDRs can be placed back-to-back on a single floor tile or alternatively against an unused wall for minimal space consumption. Designed to match your data centre The CDR has been designed to match equipment cabinets in the data centre and provide a seamless visual transition from passive racks to active racks. The CDR’s perforated curved doors are the same design as those used on the HUBER+SUHNER equipment cabinet range and the same quality look and feel is echoed across the complete portfolio. Configured to suit your needs The CDR is 47U high, 300 mm deep and comes in two standard width dimensions of 900 mm and 600 mm, designed for splicing and MTP-LC transition trays. Characteristics • • • • • • • • • • • • Only 300mm deep and completely front-accessible Lightweight 2-post design for improved access to cables Integrated cable over-length management Up to 36 fibres per tray position with MTP-LC transition tray Perforated doors to match nearby equipment cabinets Quick release doors without tools Mount against a wall or at the end of row Back-to-back mount on a single floor tile of 600 mm Large apertures for all cable types, sizes and quantities Fast installation of tray units from the front side Easy mounting of tray units with unit position number strips Side by side mounting with clear cable routing Technical data Attribute Value Dimensions (W x D x H): CDR9 CDR6 900x300x2226mm 600x300x2226mm Material Aluminium & Steel Weight: CDR9 CDR6 123.4kg 75.6kg Colour Black RAL 9005 Created by: Doc. No.: Rev:Rev.: DW CDR_900_600_DW_01 B hubersuhner.com Data sheet CDR Cable Distribution Racks Page 3 of 6 Ordering Information ODF C-Frame 900 CDR09BK GY SDPD0 1 2 0BT B L E 0 0 P 0TA Ordering Information ODF C-Frame 600 CDR06BK GY SDPD0 1 2 0BT B LE000 nn 0 X 0 X 00mmA Created by: Doc. No.: Rev:Rev.: DW CDR_900_600_DW_01 B Description CDR 900 47U Black frame Grey frame Solid doors Perforated doors No conduits fitted 1x Conduit fitted per fibre tray 2x Conduits fitted per fibre tray No conduits fitted Conduit Numbering: #1 at bottom Cable entry from the top Cable entry from the bottom Cable B/Out plate: L to R 19" & cover Cable B/Out plate: L to R 19" & cover with Extension Bar NO Cable B/Out plate Patchcord channel - none Patchcord channel - fitted No tray units fitted Tray units fitted (81 tray positions) Variant-standard Description CDR 600 47U Black frame Grey frame Solid doors Perforated doors No conduits fitted 1x Conduit fitted per fibre tray 2x Conduits fitted per fibre tray No conduits fitted Conduit Numbering: #1 at bottom Cable entry from the top Cable entry from the bottom Cable B/Out plate: L to R 19" & cover Cable B/Out plate: L to R 19" & cover with Extension Bar NO Cable B/Out plate No tray units fitted below x-connect Number of tray units fitted (standard with x-connects 30 tray positions) No Cross-connect fitted Cross-connect fitted No SecondCross-connect fitted Second Cross-connect fitted No tray units fitted above x-connect Number of tray units fitted above x-connect (standard 30) Variant-standard hubersuhner.com Data sheet CDR Cable Distribution Racks Page 4 of 6 Technical drawings CDR9 Created by: Doc. No.: Rev:Rev.: DW CDR_900_600_DW_01 B hubersuhner.com Data sheet CDR Cable Distribution Racks Page 5 of 6 CDR6 Created by: Doc. No.: Rev:Rev.: DW CDR_900_600_DW_01 B hubersuhner.com Data sheet CDR Cable Distribution Racks Page 6 of 6 CDR Floor Fixing Kits Characteristics • Secures rack to concrete substrate • Takes weight load away from tile • Cable protection sleeves for threaded bar • Expanding anchors provide strong fixation • Double nut array prevents loosening during service • Large washers provide excellent support Item number Descriptive Code Description 85029106 NGR-CONCRETE-KIT_4-P 85091849 NGR-RAISED-FLOOR-FIXING-KIT Fastening kit for raised computer floors incl. anchors, threaded-rod, nuts and washers Fastening kit for solid concrete floors incl. anchor, nuts and washers HUBER+SUHNER AG Fiber Optics Division 9100 Herisau Switzerland Tel. +41 (71) 353 41 11 Fax +41 41 (71) 353 4647 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, ISO/TS 16949 and IRIS. Note It is exclusively in written agreements that we provide our customers with warrants and representations as to the technical specifications and/or the fitness for any particular purpose. The facts and figures contained herein are carefully compiled to the best of our knowledge, but they are intended for general information purposes only. Created by: Doc. No.: Rev:Rev.: DW CDR_900_600_DW_01 B hubersuhner.com