Data sheet - Data Center

advertisement
Data sheet
CDR Cable Distribution Racks
Item number
Descriptive Code
Description
84311972
CDR09-BKPD-00-TLPT-A
84313716
CDR09-BKPD-00-BLPT-A
84313718
CDR06-BKPD-1B-TL-30XX30-A
84313720
CDR06-BKPD-1B-BL-30XX30-A
900mm wide CDR, perforated doors, no
conduit, top and bottom brush strips, top entry,
top patch exit, bottom patch channel, 81 tray
positions, Black (RAL 9005), tray units for MTP
and Miniflex
900mm wide CDR, perforated doors, no
conduit, top and bottom brush strips, bottom
entry, bottom patch exit, top patch channel, 81
tray positions, Black (RAL 9005), tray units for
MTP and Miniflex
600mm wide CDR, perforated door, 1 conduit
per tray position, #1 at bottom, top and bottom
brush strips, top entry, top patch exit, 60 tray
positions separated by 2 x-connects, Black
(RAL 9005), tray units for MTP and Miniflex
600mm wide CDR, perforated door, 1 conduit
per tray position, #1 at bottom, top and bottom
brush strips, bottom entry, bottom patch exit,
60 tray positions separated by 2 x-connects,
Black (RAL 9005), tray units for MTP and
Miniflex
Created by:
Doc. No.:
Rev.:
DW
CDR_900_600_DW_01
B
hubersuhner.com
Data sheet
CDR Cable Distribution Racks
Page
2 of 6
Highest packing density for evolving data centres
The CDR (Cable Distribution Rack) is a purpose-built high density fibre management rack which
serves as a central cross-connect in the main distribution area of data centres. With a footprint depth
of only 300 mm, the CDR is fully modular and scalable up to 1620 ports (3240 fibres) using LC
connectivity. Users can benefit from a C-shaped construction where all internal sub-elements are
completely installable and accessible from the front side. This important feature means that CDRs
can be placed back-to-back on a single floor tile or alternatively against an unused wall for minimal
space consumption.
Designed to match your data centre
The CDR has been designed to match equipment cabinets in the data centre and provide a seamless
visual transition from passive racks to active racks. The CDR’s perforated curved doors are the same
design as those used on the HUBER+SUHNER equipment cabinet range and the same quality look
and feel is echoed across the complete portfolio.
Configured to suit your needs
The CDR is 47U high, 300 mm deep and comes in two standard width dimensions of 900 mm and
600 mm, designed for splicing and MTP-LC transition trays.
Characteristics
•
•
•
•
•
•
•
•
•
•
•
•
Only 300mm deep and completely front-accessible
Lightweight 2-post design for improved access to cables
Integrated cable over-length management
Up to 36 fibres per tray position with MTP-LC transition tray
Perforated doors to match nearby equipment cabinets
Quick release doors without tools
Mount against a wall or at the end of row
Back-to-back mount on a single floor tile of 600 mm
Large apertures for all cable types, sizes and quantities
Fast installation of tray units from the front side
Easy mounting of tray units with unit position number strips
Side by side mounting with clear cable routing
Technical data
Attribute
Value
Dimensions (W x D x H):
CDR9
CDR6
900x300x2226mm
600x300x2226mm
Material
Aluminium & Steel
Weight:
CDR9
CDR6
123.4kg
75.6kg
Colour
Black RAL 9005
Created by:
Doc. No.:
Rev:Rev.:
DW
CDR_900_600_DW_01
B
hubersuhner.com
Data sheet
CDR Cable Distribution Racks
Page
3 of 6
Ordering Information ODF C-Frame 900
CDR09BK
GY
SDPD0
1
2
0BT
B
L
E
0
0
P
0TA
Ordering Information ODF C-Frame 600
CDR06BK
GY
SDPD0
1
2
0BT
B
LE000
nn
0
X
0
X
00mmA
Created by:
Doc. No.:
Rev:Rev.:
DW
CDR_900_600_DW_01
B
Description
CDR 900 47U
Black frame
Grey frame
Solid doors
Perforated doors
No conduits fitted
1x Conduit fitted per fibre tray
2x Conduits fitted per fibre tray
No conduits fitted
Conduit Numbering: #1 at bottom
Cable entry from the top
Cable entry from the bottom
Cable B/Out plate: L to R 19" & cover
Cable B/Out plate: L to R 19" & cover with Extension Bar
NO Cable B/Out plate
Patchcord channel - none
Patchcord channel - fitted
No tray units fitted
Tray units fitted (81 tray positions)
Variant-standard
Description
CDR 600 47U
Black frame
Grey frame
Solid doors
Perforated doors
No conduits fitted
1x Conduit fitted per fibre tray
2x Conduits fitted per fibre tray
No conduits fitted
Conduit Numbering: #1 at bottom
Cable entry from the top
Cable entry from the bottom
Cable B/Out plate: L to R 19" & cover
Cable B/Out plate: L to R 19" & cover with Extension Bar
NO Cable B/Out plate
No tray units fitted below x-connect
Number of tray units fitted (standard with x-connects 30 tray positions)
No Cross-connect fitted
Cross-connect fitted
No SecondCross-connect fitted
Second Cross-connect fitted
No tray units fitted above x-connect
Number of tray units fitted above x-connect (standard 30)
Variant-standard
hubersuhner.com
Data sheet
CDR Cable Distribution Racks
Page
4 of 6
Technical drawings
CDR9
Created by:
Doc. No.:
Rev:Rev.:
DW
CDR_900_600_DW_01
B
hubersuhner.com
Data sheet
CDR Cable Distribution Racks
Page
5 of 6
CDR6
Created by:
Doc. No.:
Rev:Rev.:
DW
CDR_900_600_DW_01
B
hubersuhner.com
Data sheet
CDR Cable Distribution Racks
Page
6 of 6
CDR Floor Fixing Kits
Characteristics
• Secures rack to concrete substrate
• Takes weight load away from tile
• Cable protection sleeves for threaded bar
• Expanding anchors provide strong fixation
• Double nut array prevents loosening during service
• Large washers provide excellent support
Item number
Descriptive Code
Description
85029106
NGR-CONCRETE-KIT_4-P
85091849
NGR-RAISED-FLOOR-FIXING-KIT
Fastening kit for raised computer
floors incl. anchors, threaded-rod, nuts
and washers
Fastening kit for solid concrete floors
incl. anchor, nuts and washers
HUBER+SUHNER AG
Fiber Optics Division
9100 Herisau
Switzerland
Tel. +41 (71) 353 41 11
Fax +41 41 (71) 353 4647
HUBER+SUHNER is certified according to ISO 9001, ISO 14001, ISO/TS 16949 and IRIS.
Note
It is exclusively in written agreements that we provide our customers with warrants and representations as to the technical specifications and/or
the fitness for any particular purpose. The facts and figures contained herein are carefully compiled to the best of our knowledge, but they are
intended for general information purposes only.
Created by:
Doc. No.:
Rev:Rev.:
DW
CDR_900_600_DW_01
B
hubersuhner.com