HYDRAULIC LABORATORY The hydraulic laboratory is used both with an educational purpose and as a research laboratory. Using the modern equipment from the laboratory, measurements were performed for research contracts, PhD theses and research topics for the department. Laboratory facilities CALIBRATION PUMP with weights; Bourdon tube with a measuring range 0 ... 200 kN/m2; piston area: 244.8 x 10-6 m2; piston mass: 0.5 kg mass added weight: 0.5kg, 1.0kg and 2.5kg. FLOW CHANNEL made of transparent acrylic; patterns of flow visualization: 5; width: 15 mm; length: 615 mm; depth: 150 mm; tank capacity: 0.45 l. PITOT TUBE with pressure gauge, weir, siphons (2 types), radial gate, waves generator; accessories of the existing flume and must meet the installation requirements on the Armfield flume: assembly dimensions on the basic existing Armfield hydraulic bench- width: 76 mm; height: 250 mm; DEVICE FOR DETERMINING THE PARAMETERS of discharged flow over weirs; overall dimensions: height: 160 mm; width: 230mm; wall thickness: 4 mm; dimensions of weir opening: height 82 mm; width 30 mm; triangular weir angle: 90 °; measurement needle from 0 to 150mm with 0.1 mm precision. HYDROSTATIC PRESSURE measurement device; tank capacity: 5.5 liters; distance between weights: 275 mm; cross-sectional area of the toroid: 7.5 x 10-3 m2; total depth immersion of the quadrant: 160 mm; water depth above the quadrant: 100 mm. METACENTRIC HEIGHT MEASUREMENT DEVICE; the maximum tilting angle: ± 13 °; corresponding linear dimensions: ± 90 mm; bridge size: length: 350 mm; width: 200 mm; maximum height: 475 mm. BERNOULLI'S THEOREM DEMONSTRATION DEVICE -gauge pressure range: 0300 mm; number of gauge tubes 8; tubes’ diameter: 10.0 mm; upstream diameter: 25.0 mm; upstream divergence angle: 14 °; downstream divergence angle: 21 °. DEVICE FOR DETERMINING THE IMPACT PARAMETERS of a stream against a wall; nozzle diameter: 8 mm; distance between the nozzle and the wall: 20 mm; flat wall diameter: 36 mm; impact area: 180° hemispheric surface; 120 ° conoid surface; divergence angle 30 °. DEVICE FOR MEASUREMENT OF ENERGY LOSS IN PIPES; pipe tested diameter: 3.0 mm; pipeline length: 560 mm; distance between two points of measurement: 510 mm; mercury gauge pressure area: 500 mm; water gauge pressure range: 500 mm; measuring cylinder capacity: 1000 m. DEVICE FOR REYNOLDS NUMBER MEASUREMENT; test pipe diameter: 10.0 mm; test pipe length: 700 mm; tank capacity: 0.45 liters. INTERACTIVE SMART BOARD 680 165.7 (W) x 125.7 (H) cm x 13 (D) cm or (65 1/4 (W) x 49 1/2 (H) x 5 1/8 (D) inches). PLC-XW65/PLC-XW65K SANYO Projector, LCD, 1024 x 768 maximum resolution, 2500 lumens brightness, 600:1 contrast, composite connection, D-sub 15, weight 1.6 kg, 34 dB maximum sound level. Hydraulic laboratory