DOUBLE NUTS ")| (MIN.) 35 (1") | CONDUIT (OUTLET FOR LUMINAIRE) C L 15.9 ( 150 (6") 100 (4") 19.1 (")| DRAIN PIPE, PLACED AT LOW END OF BOX CAP TYPICAL INSTALLATION OF JUNCTION BOX JB25 LOCK WASHERS (TYP.) 35 (1") - 90, LONG SWEEP ELBOW 35 (1") | CONDUIT H.S. BOLTS WITH 400 IF REQ’D. (1’-4") BOX JB25 150 BOX JB25 IF REQ’D. (6") JUNCTION JUNCTION (MIN.) SEE NOTE 5 DRILL THRU HOLES L127x127x9.5 IN BOTH LEGS OF (L5x5x) (MIN.) SUPPORT ANGLE SUPPORT ANGLE L127x127x9.5 SLOTTED HOLES (L5x5x) (MIN.) 5 (") MIN. CLR. BRACKET U-BOLT O.D. OF CONDUIT NOTE: ALL HARDWARE & AS REQUIRED STRUCTURAL STEEL TO BE GALVANIZED. CONDUIT HANGER CONDUITS & FITTINGS FOR UNDERBRIDGE LIGHTING (FOR STEEL CONDUIT ONLY) REFER TO DESIGN DRAWINGS FOR LOCATION OF OUTLETS FOR LUMINAIRES MOUNTING DETAIL FOR CONDUIT HANGER AS SHOWN IS A SUGGESTED METHOD FOR STEEL STRUCTURES. DETAILS FOR PRESTRESSED BEAMS WOULD BE SIMILAR. ALTERNATIVE DETAILS WILL BE CONSIDERED ON A CASE BY CASE BASIS. ALL DETAILS MUST BE DESIGNED FOR SPECIFIC LOADS AND DETAILED ON SHOP DRAWINGS. DO NOT MAKE ANY ATTACHMENT TO THE UNDERSIDE OF THE DECK. END OF BARRIER GUIDE RAIL (RUB RAIL NOT SHOWN FOR CLARITY) 53 (2") | CONDUIT (SEE NOTE 3) 200 + -12 (8"+ " ) - 450 (1’-6") COVER SCREWS WILL BE BRASS OR SHOULDER 200 + -12 (8"+ " ) - 600 MIN. (TYP.) (2’-0") STAINLESS STEEL, FLAT HEAD, STRAIGHT SLOT A TRAFFIC SIDE R=300 (12") ICKY 450 (1’-6") 6.4 (") BARRIER MINIMUM NUMBER AND SIZE OF CONDUITS AS REQUIRED A 300 45 (1’-0") 12.7 (") DIA.x 40 (1") GROUNDING STUD AND NUT DRAIN PIPE 53 (2") | CONDUIT CAP 600 (2’-0") JUNCTION BOX JB25 PLAN VIEW ELEVATION SECTION A - A ELEVATION SEE NOTE 4 MIN. (SECTION 1101 OF PUB. 408) CONDUIT DETAILS AT ENDS OF BRIDGE NOTES: (6") DIA. 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED. U.S. CUSTOMARY UNITS IN ( ) PARENTHESES. 3. FOR PROPER GROUNDING OF GALV. STEEL CONDUIT OR NON-METALLIC CONDUIT, SEE PUB. 408 SECTION 910. GALVANIZED TEETH TO GRIP NEOPRENE SLEEVE INSULATING BUSHING EXPANSION SAME AS OPENING IN BARRIER + 5 (1/4") HEAD 150 STAINLESS STEEL CLAMPING BANDS 2. PROVIDE MATERIALS AND WORKMANSHIP IN ACCORDANCE WITH PUB. 408. MOLDED NEOPRENE SLEEVE 5. BLISTER IS NOT REQUIRED FOR JUNCTION BOX JB25 WHERE BARRIER WIDTH PROVIDES MINIMUM CONCRETE COVER OF 75 mm (3"). GALVANIZED SILICON BRONZE COUPLINGS GALVAZINED STEEL OVERSIZE GALVANIZED STEEL CONDUIT SLEEVE FIXED HEAD 6. MINIMUM CENTER TO CENTER SPACING OF JUNCTION BOXES IN BRIDGE PARAPETS 53 (2") | CONDUIT NIPPLE 53 (2") | CONDUIT 4. CONDUIT TO EXIT BARRIER ON OUTSIDE OF GUIDE RAIL POST LINE TO AVOID DAMAGE TO CONDUIT. TO BE 3000 (10’-0"). BOXES TO BE A MINIMUM OF 3000 (10’-0") FROM OPEN JOINT. 7. MAXIMUM NUMBER OF CONDUITS PERMITTED TO BE PLACED IN BRIDGE BARRIER (4") APPROX. C L 100 ") (3 100 APPROX. IS FOUR. CONDUITS MUST BE STAGGERED AND AS WIDELY SPACED AS PRACTICAL. NOTE: EITHER ALL METRIC OR ALL ENGLISH VALUES MUST BE USED ON PLANS. METRIC AND ENGLISH VALUES SHOWN MAY NOT BE MIXED. C L COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF DESIGN TINNED FLEXIBLE COPPER BRAID BONDING JUMPER TO GROUND CONNECTION (NOT REQ’D FOR PVC ON DEFLECTION FITTING. CONDUIT WITH SEPARATE OPENING GROUND WIRE) + IN 210 (8") APPROX. BARRIER AS PER DESIGN DRAWINGS PROVIDE TINNED COPPER BRAID STANDARD BONDING JUMPER WHEN REQUIRED LENGTH OF EXPANSION FITTING FOR GROUND CONTINUITY WHEN (180 (7") TYPICAL USING STEEL CONDUIT. ELECTRICAL DETAILS FOR 100 (4") MOVEMENT) + PROVIDE SLEEVE OF SUFFICIENT LENGTH TO ACCOMMODATE MAXIMUM EXPANSION AND CONTRACTION OF EXPANSION JOINT. CONDUIT EXPANSION AND DEFLECTION JOINT FITTINGS BC-739M BRIDGE BARRIER TO GUIDE RAIL TRANSITION BC-722M LIGHTING POLE ANCHORAGE REFERENCE DRAWINGS RECOMMENDED OCT.26, 2010 CHIEF BRIDGE ENGINEER RECOMMENDED OCT.26, 2010 DIRECTOR, BUREAU OF DESIGN SHEET 1 OF 2 BC-721M CONDUIT EXPANSION NOTES ONE SIZE LARGER CLAMP GIRDER OR BEAM (TYP.) A THAN CONDUIT SIZE TO (SPREAD BOX BEAM SHOWN) PERMIT TEMPERATURE 1. APPROXIMATE LENGTH OF FLEXIBLE CONDUIT IS 2 TIMES ANTICIPATED MOVEMENT OR EXPANSION OF CONDUIT 300 (1’-0") MIN. PLUS 900 (3’-0"). 2. SIZE BOX PER NEC314. 3. FOR UNDERBRIDGE LOCATIONS, BOXES CAN BE USED IF KEPT INACCESSABLE FROM GENERAL PUBLIC AND PLACED A MIN. 3 000 (10’-0") ABOVE SURROUNDING GROUND. CONDUIT 4. PULL BOX USE IS OPTIONAL, IF NEEDED, USE CAST IRON OR WELDED STEEL WHICH IS HOT " WIDE HOT DIP DIPPED GALVANIZED PER PUB.408, SECTION 1101.10. GALV. SPACER P L SUBSTRUCTURE CLAMP CONDUIT OPTIONAL PULL BOX 300 CONDUIT LIQUIDTIGHT FLEXIBLE (1’-0") NON-METALIC CONDUIT B B FITTING EXPANSION CLAMP FIXED CLAMP OVERSIZED CLAMP FOR EXPANSION OF CONDUIT CONDUIT CLAMP DETAILS PVC CONDUIT BEAM SEAT SURFACE MOUNTED A PULL BOX 50 (2") BRIDGE MIN. SUPERSTRUCTURE PLAN LIQUIDTIGHT FLEXIBLE NON-METALIC CONDUIT SEE NOTE 1 FOR LENGTH. OPTIONAL PULL BOX LIQUIDTIGHT FLEXIBLE NON-METALIC CONDUIT WEEP HOLE AT LOW POINT SECTION B-B SECTION A-A BOX USED FOR LARGER MOVEMENTS NOTES: EXPOSED CONDUIT CONNECTIONS 1. REFER TO PUBLICATION 408, SECTION 910.3(q) FOR GROUNDING. 2. GROUND METAL CONDUIT. PROVIDE AN AWG#4 BONDING JUMPER WHEN AT EXPANSION JOINTS (6") DIA. NECESSARY FOR GROUND CONTINUITY. STAINLESS STEEL CLAMPING BANDS TEETH TO GRIP NEOPRENE SLEEVE 150 MOLDED NEOPRENE SLEEVE SILICON BRONZE COUPLINGS RUBBER 53 (2") | PVC OR FRE CONDUIT CONDUIT NIPPLE O-RING COUPLING 53 (2") | PVC ") (3 100 APPROX. OR FRE CONDUIT C L C L NOTE: EITHER ALL METRIC OR ALL ENGLISH VALUES MUST BE USED ON PLANS. METRIC AND ENGLISH VALUES SHOWN MAY NOT BE MIXED. COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF DESIGN OPENING + IN 210 (8") APPROX. BARRIER STANDARD LENGTH OF EXPANSION FITTING AS PER ELECTRICAL DETAILS DESIGN DRAWINGS OPTIONAL PVC CONDUIT EXPANSION AND DEFLECTION JOINT FITTINGS + PROVIDE SLEEVE OF SUFFICIENT LENGTH TO ACCOMMODATE MAXIMUM EXPANSION AND CONTRACTION OF EXPANSION JOINT. RECOMMENDED OCT.26, 2010 CHIEF BRIDGE ENGINEER RECOMMENDED OCT.26, 2010 DIRECTOR, BUREAU OF DESIGN SHEET 2 OF 2 BC-721M