® 2 100 SYSTEM FEATURES • Protects facilities and equipment against the harmful effects of lightning strikes and internally generated electrical transients • Individually fused MOV’s provide superior protection and continuous operation • 200 kAIC short circuit current rating allows direct bus connection without the need of an upstream over-current protection device • Includes pre-wired pigtail conductors to stream line installation • Low profile design has an optional flush-mount plate for in-wall recessed panel applications • UL 1283 EMI/RFI filter • Ultra Compact Footprint – makes installation flexible • Enhanced Transient Filter for better protection of electronic loads • 25-Year Unlimited Free Replacement Warranty • Status indicator lights (LED) PRODUCT SPECIFICATIONS GENERAL SPECIFICATIONS AVAILABLE CONFIGURATIONS Maximum Rated Surge Current: 100kA per phase (50kA/mode) Repetitive Surge Current Rating: 3,000 impulses per mode based on actual test data (using ANSI/IEEE C62.41.1-2002 C3 combo wave) Application: ANSI/IEEE C62.41 Location C, B & A. Ideal for distribution panels, branch panels and critical loads Design: Hybrid parallel design with individual fused MOV’s and UL 1283 EMI/RFI filter Warranty: 25-Year Unlimited Free Replacement Safety Listing: UL 1449 4th Ed., Type 1 for Type 1 & Type 2 locations and UL 1283 Model Number TK-TT2-100-3D240-FL 120/240VAC, 3ø high-leg DELTA, 4-wire + grd (B phase must be 208V) ELECTRICAL SPECIFICATIONS TK-TT2-100-240NN-FL 240VAC, Three-Phase, 3-wire + grd Modes of Protection: All modes: L-N, L-G, N-G & L-L Input Power Frequency: 47-63Hz Connection Method: Parallel to electrical distribution system Response Time: Less than 1 nanosecond Standard Monitoring: Status indicator lights (one per phase) Short circuit Current Rating: 200 kAIC – no upstream over-current protection device (breaker or fuse) required. MECHANICAL SPECIFICATIONS Dimensions (approx.): 6”H x 6”W x 4”D (160 mm H x 160 mm W x 102 mm D) Enclosure: Powder coated, impact-resistance steel, weather-proof NEMA 4 (IP56) Connection: Pre-wired with 30”(915 mm) of #10 AWG (5.26 mm2) conductor Mounting: Dual mounting flanges Operating Environment: -40° C to 70° C (-40° F to 160° F) 5% to 95% non-condensing humidity Weight: 10 lbs. (4.5 kg) Description TK-TT2-100-1P120-FL 120VAC, Single-Phase 2-wire + grd TK-TT2-100-1P240-FL 240VAC, Single-Phase 2-wire + grd TK-TT2-100-1S240-FL 120/240VAC, Split-Phase, 3-wire + grd TK-TT2-100-3Y208-FL 120/208VAC, Three-Phase, 4-wire + grd TK-TT2-100-3Y380-FL 220/380VAC,Three-Phase, 4-wire + grd TK-TT2-100-3Y480-FL 277/480VAC,Three-Phase, 4-wire + grd AVAILABLE OPTIONS • Monitoring package (Form C dry relay contacts + audible alarm with mute button) : add suffix "-M" Stand-Alone Option (To Be Ordered as a separate Item) • TT2-FMP Flush-Mount Plate Kit EMI / RFI FILTER ATTENUATION – MIL STANDARD 220B Max. Attenuation Frequency 40 dB @ 100 kHz FREE ENT CEM REPLA WARRANTY WARRANTY 25 YEAR 25 YEAR UL 1449 Made in U.S.A. Page 1 of 2 ® SIDE VIEW FRONT VIEW 1/2" Chase Nipple 3/4 to 1/2" Threaded Reducer 3/4" Myers Hub Ø0.31 [7.94] (4X) 3.14 [79.8] 2 100 2.82 [71.6] • • 7.64 [194.1] For 120/208V Configuration 6.89 [175.0] 6.28 [159.5] 4.28 [108.7] 4.00 [101.6] 6.28 [159.5] ANSI/IEEE C62.41.1 Category A1 Ring Wave 2000V, 67A Test Plot L-N Mode, Dynamic, 180 Phase Angle, 6" Leads, Positive Polarity 1 msec/div Horizontal 45V/div Vertical AC Sine Wave All measurements in inches [mm] ANSI/IEEE C62.41.1-2002, C62.41.2-2002, & C62.45-2002 Measured Limited Voltage Model Number System Voltage Peak Let-Through Voltage Level - 36V Reference Level Zero Crossing of AC Sine Wave UL Voltage Ratings UL 1449 2nd Edition/ A1 Ring Wave B3/C1 Impulse Wave C3 Impulse Wave UL1449 3rd & 4th Ed. Voltage Protection 2kV, 67A 6kV, 3kA 20kV, 10kA 180° Phase Angle 90° Phase Angle 90° Phase Angle Ratings System Configuration Protection Mode MCOV 1-Phase 2-wire+grnd L-N L-G N-G 150V 150V 150V 42V 541V 765V 590V 597V 590V 970V 1160V 1100V 400/600 400/600 400/600 L-N L-G N-G L-N L-G L-L N-G L-N L-G L-L N-G L-N L-G L-L N-G L-N L-G L-L N-G 320V 320V 320V 150V 150V 300V 150V 150V 150V 300V 150V 320V 320V 640V 320V 320V 320V 640V 320V 42V 541V 765V 36V 283V 56V 322V 36V 283V 56V 322V 42V 541V 63V 765V 42V 541V 63V 765V 1038V 1037V 1037V 590V 597V 980V 590V 590V 597V 980V 590V 1040V 1037V 1860V 1035V 1040V 1037V 1860V 1035V 1660V 1690V 1510V 970V 1160V 1490V 1100V 970V 1160V 1490V 1100V 1660V 1690V 2570V 1510V 1660V 1690V 2570V 1510V 800/1200 800/1200 800/1200 400/600 400/600 800/1000 400/600 400/600 400/600 800/1000 400/600 800/1200 800/1200 1500/2000 800/1200 800/1200 800/1200 1500/2000 800/1200 150V 320V 150V 320V 320V 470V 150V 36V 39V 283V 735V 31V 71V 303V 598V 1041V 595V 1042V 988V 1394V 595V 960V 1326V 1160V 1495V 1490V 1629V 860V 400/600 800/1200 400/600 800/1200 800/1000 1500/1500 400/600 320V 300V 525V 70V 1039V 978V 1500V 1300V 800/1200 800/1000 TK-TT2-100-P120-FL 120V TK-TT2-100-1P240-FL 240V TK-TT2-100-1S240-FL 120/240V Split-Phase 3-wire+grnd TK-TT2-100-3Y208-FL 120/208V 3-Phase WYE 4-wire+grnd TK-TT2-100-3Y380-FL 220/380V 3-Phase WYE 4-wire+grnd TK-TT2-100-3Y480-FL 277/480V 3-Phase WYE 4-wire+grnd 1-Phase 2-wire+grnd TK-TT2-100-3D240-FL 120/240V 3-Phase high-leg DELTA 4-wire+grnd L-N H-N L-G H-G L-L H-L N-G TK-TT2-100-240NN-FL 240V 3-Phase DELTA 3-wire+grnd L-G L-L All tests performed with 6" (152 mm) lead length, positive polarity. All voltages are peak values (±10%) measured from the zero reference point at the phase angles referenced above using a 10 µs/div display rate and 500 Mega samples/sec sampling rate. Specifications subject to change without notice. See web site www.TPSsurge.com for latest revisions. ©2010 Total Protection Solutions, LLC TransTrack® and Total Protection for life® are regestered trademarks of Total Team Solutions\ 6.28.10/TT2100 Page 2 of 2 For Technical Support: TEL: 800.647.1911 www.TPSsurge.com P.O. Box 3760, Winter Park, FL 32790-3760