2 A}+HHXT"T&.E.T-A *#$ SCHOOL OF BIOMEDICAT ENG!NEERING QI'OTATION ENQUIRY Ref: rrr (BHU)/BME/ r S -tl lqrnt Z Zz-f d Due Date:o8/ol laolL Date: (Last date of quotation receiving) I f/ i :-Taot s- (Dote altender enquiry) To, Dear Sir, your lowest rate for supplying the under mentioned items. euot6tion in duplicate must reach us before the date marked above and should contain the following information: 8' Full specification and make of the item offered and its rate F.o.R. Varanasi 9' Sales tax at concessional rate as applicable to educational institution. Please submit 10. Your VAT / CST registration number, pAN & TtN numbers. 11. Conditions of supply and terms of payment. 12' lf you are a manufacture of the item or if you have proprietary right over it, please mention it in the quotation and provide a certificate. 13' Please mention your agency commission in lndianRs., if applicable (in case of imported items). 14. Please give undertaking as per annexure_l_B Quotation must be sent in a sealed envelope with word "euorATIoN", our reference number, and due date as given above, clearly marked over it. s.N. 1 2 Name of Items Non-lnvasive Automated Blood Pressure - Volume Pressure Recording Tail-Cuff System Laser Tissue Blood Flowmeter (Applicable for Rodent BrainJ Discription / Technical Specifi cation Measurement: blood pressure parameters; - t4il blood volume and blood flow Measurement o o o i Tissue Blood Flow (FLOWI Tissue Blood Volume IMASSJ Tissue Blood Velocity (VELOCITYI Measureme4t depth: about \ /aolt The Sealed quotations will be opened on I\/o Biomedical Engineering (This is mandatory in case of L mm at 12:15 PM in the office of Schootof e-publishing). n ?\N)u.*rY-- .P" K*f 1 - systolic, diastolic, and mean Bp - heart rate N.B. : Other technical specifications are attached A Quantity ^- fiq iqf;rwr.riiTqfErdt qr SCHOOL OF BIOMEDICAL ENGG *n,ir..r frdrFrfr frr+lra INDIAN INSTITUTE OF TECHNOLOGY i, ii 1 1,,.,,. ; 7 [EC-.Jh_{HC BANARAS iiI ;.IOU UNIVERSITY :;rotgii-22166U V.:.ltrii..iASl-22 1 0os Other technical specifications 1. Automated NIBP - Volume Pressure Recording Tail-Cuff System Instrument should include Controller, Software, 1-Channel Activation, and Stand Able to measure 6 blood pressure parameters: * Systolic, diastolic, and mean BP * heart rate * Tail blood volume and blood flow 631,996 631,996 * Actual Diastolic BP detection, not just a calculated * Actual Diastolic BP detection, not just a calculated value Suitable for Mice as small as 8 grams to Rats larger than 950 grams MRI Compatible Also provide: 1) HLD-RM Medium Rat Holder, 200 to 300g 2) RAT-CUFFKIT VPR Sensor & Occlusion Cuff Kit- Rat 3) IR-PLT4 Warming Platform for up to 4 animals, includes infrared thermometer 2. Laser Tissue Blood Flowmeter Laser Power at Probe: < 3mW Electrode type: Surface electrode and Needle electrode Laser for measurement Wavelength : 780nm, Semiconductor laser, CLASS 1M Tissue Blood Flow (FLOW) FLO-C1 : 0 - 100.0 (mL/min/100g equivalent) Tissue Blood Volume (MASS) 0 - 2000 (arbitrary unit) Blood Flow Velocity (VEL.) FLO-C1 : 0 - 10.00 (KHz) Measurement area: inside about 1 mm circle Measurement depth: about 0.5 - 1 mm (depens on tissue) Output: 0 -10V Analog Time constant: 0.1, 1, 3 sec Optical connector: FC Optical fiber probe: 100/140µm, GI Power: 220 V AC Annexure-I-B ANNEXURE-I-C