A Three Phase, Double Conversion, PWM, High Performance UPS... True On Line Operation The OnLine Power Industrial Grade 3000 represents the highest performance on line UPS technology in which the transistorized inverter is continuously providing superior power protection for today’s rapidly changing industrial and data processing hardware platforms. High Reliability Industrial Grade 3000 offers the highest level of reliability available in true on line UPS Systems. Observed mean time between failure (MTBF) is in excess of 400,000 hours. This has been achieved through conservative design philosophy, extremely low parts count, state of the art logic & control circuitry and built-in static and maintenance bypass switches. High Efficiency Industrial Grade 3000 is the most cost effective solution to your power problems. With 92% operating efficiency at full load, the input power requirement is significantly lower than other competitive products. Higher efficiency also reduces air conditioning requirements. As a result, “cost of ownership” is among the lowest in the industry. Transistorized Inverter Continuous Duty Static Switch UPS 3000 static switch is a continuous duty, fully rated assembly providing a means of transferring the critical load from inverter to reserve input during excessive overloads and fault clearing. Maintenance Bypass Switch Industrial Grade 3000 has a built in maintenance bypass switch in the UPS cabinet. The switch allows the critical load to be directly fed from the utility during routine maintenance, a feature most desired by field service engineers and technicians. Ease of Installation Industrial Grade 3000 is designed to accommodate conduit/ cable entry from the top or bottom. All power cables for rectifier input, maintenance bypass input & system output terminate on individual terminal blocks with Allen screws, eliminating the need for pressure connectors. The unit can be placed against the wall as no rear access is required. • UL LISTED • UL 924 (Optional) • High Reliability • High Efficiency • Acoustically Quiet • Ease of Installation • Full Double Conversion • Fully Rated Static Switch • Maintenance Bypass Switch • Transistorized Inverter Suitable for 100% Non-Linear Loads with 3.5 Crest Factor • 5 Year Factory Warranty (3ø Uninterruptible Power Supply) Switching mode power supplies (SMPS) are an integral part of practically all industrial data Processing/ Computing equipment used in today’s industrial applications and office environments. These SMPS present highly non-linear loads to the UPS. Non-linear loads have voltage wave form distortion. Industrial Grade 3000 utilizes state-of-the-art, IGBT’s pulse width modulated (PWM) inverter technology that produces an output voltage wave form compatible with today’s automated industrial equipment and computer systems. • 15 to 100 kVA Industrial Grade 3000 The TANK STANDARD FEATURES OPTIONS • UL 924 • Main Input Breaker • Remote Emergency Power OFF (REPO) Stat ion with 50 ft. Cable • Reserve Input Circuit Breaker • Transistorized Inverter • Thermal Remote Emergency Power OFF (REPO) Station with 50 ft. Cable • Continuous Duty Static Switch • IBM AS/400 Interface Cable and Connector • 5% Input Harmonic Distortion Filter • Maintenance Bypass Switch • Remote Panel w/Summary Alarm • Power Cable Terminal Blocks • Computer Grade Bypass Transformer • IBM AS/400 Interface Circuitry • Power Distribution Panel • System Monitoring • Emergency Power OFF (EPO) • Multiple Software • Special Paint INDUSTRIAL GRADE 3000 SPECIFICATIONS ENVIRONMENT INPUT **Voltage . . . . . . Voltage Range . . . Wiring . . . . . . . . . Power Factor . . . . . ***Frequency Range Power Walk-In . . . . . Magnetizing In Rush . Current Limit . . . . . . . . . . . . . . . . .. .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208Y/120, 480Y/277 VAC +10%, -15% 3 Phase, 3 Wire and Ground 0.85 60 Hz. +5% 20 to 100% in 15 Sec. 5-8 times normal Full Load current 100-125% of normal Full Load current adjustable Protection . . . . . . . . . . . . . . . . . Molded case circuit breaker with single phase protection. Current limit fuses. OUTPUT Voltage 60 Hz . . . . . . . . . . . . . 208Y/120 or 480Y/277 VAC Wiring . . . . . . . . . . . . . . . . . . . 3 Phase, 4 Wire and Ground Voltage Regulation Balanced Load . . . . . . . . . . . +0.5% 50% Unbalanced . . . . . . . . . +2% 100% Unbalanced . . . . . . . +5% Frequency (Regulation) . . . . . . +0.1% Efficiency . . . . . . . . . . . . . . . 92% Load Power Factor . . . . . . . . 0.7 Lag to 0.9 Lead Phasing Balance Balanced Load . . . . . . . 120˚ +1˚ 50% Unbalanced . . . . . 120˚ +1˚ 100% Unbalanced . . . 120˚ +3˚ Total Harmonics . . . . . . 3% RMS Max. Single Harmonics . . . . 1% RMS Max. Overload at . . . . . . . 125% of Full Load for 10 Minutes. Nominal . . . . . . . . . 150% of Full Load for 30 seconds. Current Limit . . . . . 150% FL current at reduced voltage Fault Clearing Capability . . . 300-400% sub-cycle Voltage Transients 50% Load step . . . . . . +3% 100% Load step . . . . . +5% Loss or return of redundant module . . . +3% Automatic transfer . . . +3% Load to Bypass Manual Return . . . . +1% Load to UPS Response Time . . Recovery to 99% of steady state in 1 cycle. IG3-6022E-404 © Copyright OnLine Power, Inc. All rights reserved. R Operating Temp. . . . . . . . . . . UPS: 0˚ to 40˚C. (32˚ to 104˚F.) Battery: 20˚ to 30˚C. (68˚ to 86˚F.) Non-operating Temp. . . . . . . . -20˚ to 70˚C. (-4˚ to 158˚F.) Battery Temp. . . . . . . . . . . . . Average annual temperature less than 27˚C. (80˚F.). Peak temperature less than 43˚C. (110˚F.) for more than 24-hour period. Relative Humidity . . . . . . . . . . 5-95% Non-condensing Altitude Operating . . . . . . . . . . . . . Up to 7,500 ft. (2,286 m) Non-operating . . . . . . . . . . Up to 10,000 ft. (3,048 m) Acoustical Noise . . . . . . . . <45 dB at 6 ft. Dimensions . . . . . . . . . . . . . . Width Depth Height 34" x 34" x 69" kVA INPUT OUTPUT SIZES VOLTAGE VOLTAGE 15 20 25 30 37.5 50 62.5 75 100 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 480 VAC 480 VAC 480 VAC 480 VAC 480 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC 208 VAC 480 VAC MODEL NUMBERS UP015B0500T3 UP015H0900T3 UP020B0500T3 UP020H0900T3 UP025B0500T3 UP025H0900T3 UP030B0500T3 UP030H0900T3 UP037B0500T3 UP037H0900T3 UP050B0500T3 UP050H0900T3 UP062H0500T3 UP062H0900T3 UP075H0500T3 UP075H0900T3 UP100H0500T3 UP100H0900T3 BATTERY CABINET WEIGHT 15 Min 30 Min 45 Min BTU's/HR UPS WEIGHTS 4,440 1,655 LBS 1,243 1,495 2,900 5,900 1,998 LBS 1,618 2,050 3,270 7,400 2,092 LBS 1,800 2,144 3,900 8,900 2,186 LBS 2,144 2,800 4,100 11,100 2,331 LBS 2,144 2,800 4,900* 15,000 2,566 LBS 2,800 4,940* 5,600* CONSULT FACTORY * Two (2) Battery Cabinets. ** Other input voltages available; contact factory sales department for more information. *** For modified units & 50 Hz models, consult factory Specifications are subject to change without prior notification. 5701 Smithway St. Commerce, CA 90040 Phone: (800) 227-8899 Fax: (323) 721-3929 www.onlinepower.com