Product line E11 E11 New! New! Circuit protection system ETI Elektroelement d.d. Obrezija 5, SI - 1411 Izlake Slovenia Phone: + 386 03 56 57 570 Fax: + 386 03 56 74 077 eti@eti.si www.etigroup.eu PRODUCT LINE E11 Miniature circuit breakers Miniature circuit breakers ETIMAT11 Advantages of miniature circuit breakers ETIMAT11 Sealing cover Sealing possibility “ON/OFF” mark on the switch button Locking device Better protection of terminals against touching the parts under voltage New method of mounting on the DIN rail and simple replacement Double connection possibility Every product is marked with EAN code Option of mounting auxiliary devices (auxiliary switch, shunt trip) 2 PRODUCT LINE E11 Miniature circuit breakers PS/SS Auxiliary signal switch for ETIMAT11 A device which can either be set up as an auxiliary switch or a signal switch; depending on the setting selected, this device may be used for remote indication of the current switching status of a switching device in the type series ETIMAT11 MCB. Auxiliary switch = contact position indication Signal switch = indication device tripped on fault occurrence This switch may be used as a potential-free break/make or break/change-over contact. Even in an assembly, all terminals are easily accessible from above. Installation and operation: This switch is mounted together with the switching device on the support rail. If required, therefore, both may be removed together from the assembly and replaced. Before fitting, the universal auxiliary switch will be set to the desired function auxiliary switch or signal switch by turning the adjusting-screw, marked by an appropriate label (fig.1) On the relevant switching device, an aperture for the tripping pin is provided; this aperture is broken out (fig. 2) Auxiliary switch PS/SS E11 type contacts PS/SS E11 1xNC, 1xNC/NO NC - normally closed contact NO - normally opened contact Connection to the switching device is effected by two retaining clamps, operation is effected via the tripping pin or the connecting piece to the toggle switch (fig. 3) For test purposes, the universal auxiliary switch (in assembled condition) may be operated without actuation of the switching device. To this end, the connecting pin to the protective switching device toggle is withdrawn; then, using a small screwdriver, activate the function TEST of the auxiliary switch (fig.4) Fig.1 Fig.2 Fig.3 Fig.4 ETIMAT11 RC - Remote control ETIMAT11 RC is a miniature circuit breaker with remote control mechanism. ETIMAT11 RC provides following advantages: • • • • • • • • • • remote switching with simultaneous protection minimal space requirement straightforward actuation can be used as actuator in any instalation bus system secure against remote activationafter manual switch-of and/or being tripped by overcurrent control coil protected against thermal overload easy instalation assured by rapid fastening method visual status display : red/ON, green/OFF sealable control lever capability of adding an auxiliary switch Technical Data: • • • the remote control mechanism, which serves to actuate ETIMAT11 RC is conected to Etimat11 MCB by the factory before dispatch the remote control mechanism is activated electro-magneticaly by the application of a control voltage acc. to following data: rated voltage: 230V a.c. exciting current: approx 1.5A, duration min 20msek • No. of operations: • 20.000 , max 12 per minute 3 PRODUCT LINE E11 Miniature circuit breakers ETIMAT11 QC - Quick connect Use rigid wire Connecting the wire with cross section from 1,5 to 4 mm2 Voltage test Disconnecting the wire - press the button 4 PRODUCT LINE E11 Miniature circuit breakers Miniature circuit breaker ETIMAT11 Characteristics I/t characteristics at 50 and 60Hz min. 2 1min. 1min. 4 2 2 10s 10s t 4 6 4 6 4 2 1s 6 1s 6 sek. 2 4 4 2 2 100ms 100ms 6 6 4 4 2 2 10ms 10ms 6 6 1 1.5 2 3 NxI 5 10 20 4 30 1 1.13 1.45 min. 100 10 2 1min. 4 4 2 2 10s 10s 6 4 2 1s 6 1s 6 4 2 100ms 100ms 6 6 4 4 2 2 10ms 10ms 6 6 3 NxI 5 10 n 20 30 5 10 20 30 10 20 30 n 1.05 1.2 4 2 2 NxI 6 4 2 1.5 3 10 2 1 2 120 1min. 4 1.5 n t min. t 10 2 100 sek. 1.13 1.45 100 10 4 1.13 1.45 sek. sek. t min. 100 4 1 1.5 2 3 NxI 5 n 5 Miniature circuit breaker ETIMAT11 Characteristics Effect of the ambient temperature on the tripping characteristic 70 Corection factor is valid for current with times over 30 s I(x°C) -test current at x ambient temperature I(30°C) - test current at 30°C ambient temperature T/ C ° 60 50 In [A] 0,5 1 1,6 2 4 6 10 13 16 20 25 32 40 50 63 40 30 20 10 0 -10 -20 I(x°C) -30 -40 k= ----------------I(30°C) 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 10 -40 0,61 1,22 1,95 2,44 4,88 7,32 12,2 15,9 19,5 24,4 30,5 39 48,8 61 76,9 6 2 B63 10 8 B50 8 6 B40 B32 4 B25 B20 3 B16 2 B10 B13 4 2 2 5 5 Ip/A B6 C50 C40 C32 C25 C20 3 C16 C10 C13 2 10 6 5 C63 5 4 6 C6 4 5 4 4 3 3 2 2 3 10 3 1.5 2 2.5 3 4 5 6 7 8 10 9 10 4 3 10 3 1.5 Prospective current I p (A) 10 2 I t/As 6 6 5 5 4 5 6 7 8 9 10 4 2 Ip/A 2 5 10 6 D32 5 D25 D20 4 3 D16 D10 D13 D6 2 4 2 2 8 Max. operating I t (A s) 2 2 2 3 2 6 3 6 5 5 4 4 3 3 2 2 2 2.5 3 4 5 6 7 8 9 10 4 K16 K10 K13 2 6 1.5 K25 K20 4 8 10 3 K32 5 10 3 5 8 8 Prospective current I p (A) 6 3 I t/As 4 Ip/A 3 2.5 6 8 2 4 2 Prospective current I p (A) 6 8 10 70 0,38 0,75 1,2 1,5 3 4,5 7,5 9,75 12 15 18,8 24 30 37,5 47,3 2 5 8 10 60 0,41 0,82 1,32 1,65 3,29 4,94 8,23 10,7 13,2 16,5 20,6 26,3 32,9 41,2 51,9 6 8 10 50 0,44 0,88 1,42 1,77 3,55 5,33 8,89 11,5 14,2 17,7 22,2 28,4 35,5 44,4 56 2 Max. operating I t (A s) 2 2 2 3 2 10 40 0,47 0,94 1,51 1,88 3,77 5,66 9,44 12,2 15,1 18,8 23,6 30,2 37,7 47,2 59,4 I t/As 4 Ip/A 3 10 Ambient temperature T/OC 0 10 20 30 0,56 0,54 0,52 0,5 1,12 1,09 1,05 1 1,79 1,74 1,68 1,6 2,24 2,18 2,1 2 4,49 4,36 4,20 4 6,73 6,54 6,31 6 11,2 10,9 10,5 10 14,5 14,1 13,6 13 17,9 17,4 16,8 16 22,4 21,8 21 21 28 27,2 26,3 25 35,9 34,9 33,6 32 44,9 43,6 42 40 56,1 54,5 52,6 50 70,7 68,7 66,2 63 5 4 10 -10 0,57 1,15 1,84 2,30 4,61 6,91 11,5 14,9 18,4 23 28,8 36,9 46,1 57,6 72,6 6 5 10 -20 0,59 1,18 1,89 2,36 4,72 7,09 11,8 15,4 18,9 23,6 2,5 37,8 47,8 59,1 74,4 6 8 2 I t/As 6 Max. operating I t (A s) -30 0,6 1,2 1,92 2,4 4,8 7,2 12 15,6 19,2 24 30 38,4 48 60 75,6 10 8 Max. operating I t (A s) PRODUCT LINE E11 Miniature circuit breakers 10 K6 4 3 10 3 1.5 2 2.5 3 4 5 6 Prospective current I p (A) 7 8 9 10 4 PRODUCT LINE E11 Miniature circuit breakers Miniature circuit breaker ETIMAT11 Rated short-circuit capacity 10 kA 1-pole ln [A] 0,5 1 2 4 6 10 13 16 20 25 32 40 50 63 Un [V] 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 1-pole + N ln [A] 0,5 1 2 4 6 10 13 16 20 25 32 40 50 63 Un [V] 230 230 230 230 230 230 230 230 230 230 230 230 230 230 2-pole ln [A] 0,5 1 2 4 6 10 13 16 20 25 32 40 50 63 Un [V] 400 400 400 400 400 400 400 400 400 400 400 400 400 400 Rated current 0,5 - 63 A Tripping characteristic B, C, D, K code No. B code No. C code No. D code No. K 700600102 701000105 701300104 701600103 702000106 702500101 703200103 704000108 705000109 706300109 700501100 700101108 700201101 700401107 700601103 701001106 701301105 701601104 702001107 702501102 703201104 704001109 705001100 706301100 700502101 700102109 700202102 700402108 700602104 701002107 701302106 701602105 702002108 702502103 703202105 700503102 700103100 700203103 700403109 700603105 701003108 701303107 701603106 702003109 702503104 703203106 code No. B code No. C code No. D code No. K 700610109 701010102 701310101 701610100 702010103 702510108 703210100 704010105 705010106 706310106 700511107 700111105 700211108 700411104 700611100 701011103 701311102 701611101 702011104 702511109 703211101 704011106 705011107 706311107 700512108 700112106 700212109 700412105 700612101 701012104 701312103 701612102 702012105 702512100 703212102 700513109 700113107 700213100 700413106 700613102 701013105 701313104 701613103 702013106 702513101 703213103 code No. B code No. C code No. D code No. K 700620106 701020109 701320108 701620107 702020100 702520105 703220107 704020102 705020103 706320103 700521104 700121102 700221105 700421101 700621107 701021100 701321109 701621108 702021101 702521106 703221108 704021103 705021104 706321104 700522105 700122103 700222106 700422102 700622108 701022101 701322100 701622109 702022102 702522107 703222109 700523106 700123104 700223107 700423103 700623109 701023102 701323101 701623100 702023103 702523108 703223100 weight [g] 124 124 124 124 124 121 121 121 121 121 121 130 130 130 packaging [pcs] 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 weight [g] 249 249 249 249 249 245 245 245 245 245 245 261 261 261 packaging [pcs] 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 weight [g] 249 249 249 249 249 245 245 245 245 245 245 261 261 261 packaging [pcs] 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 7 PRODUCT LINE E11 Miniature circuit breakers 3-pole ln [A] 0,5 1 2 4 6 10 13 16 20 25 32 40 50 63 Un [V] 400 400 400 400 400 400 400 400 400 400 400 400 400 400 3-pole + N ln [A] 0,5 1 2 4 6 10 13 16 20 25 32 40 50 63 Un [V] 400 400 400 400 400 400 400 400 400 400 400 400 400 400 code No. B code No. C code No. D code No. K 700630103 701030106 701330105 701630104 702030107 702530102 703230104 704030109 705030100 706330100 700531101 700131109 700231102 700431108 700631104 701031107 701331106 701631105 702031108 702531103 703231105 704031100 705031101 706331101 700532102 700132100 700232103 700432109 700632105 701032108 701332107 701632106 702032109 702532104 703232106 700533103 700133101 700233104 700433100 700633106 701033109 701333108 701633107 702033100 702533105 703233107 code No. B code No. C code No. D code No. K 700640100 701040103 701340102 701640101 702040104 702540109 703240101 704040106 705040107 706340107 700541108 700141106 700241109 700441105 700641101 701041104 701341103 701641102 702041105 702541100 703241102 704041107 705041108 706341108 700542109 700142107 700242100 700442106 700642102 701042105 701342104 701642103 702042106 702542101 703242103 700543100 700143108 700243101 700443107 700643103 701043106 701343105 701643104 702043107 702543102 703243104 code No. B code No. C code No. D code No. K 710600109 711000102 711300101 711600100 712000103 710501107 710101105 710201108 710401104 710601100 711001103 711301102 711601101 712001104 710502108 710102106 710202109 710402105 710602101 711002104 711302103 711602102 712002105 710503109 710103107 710203100 710403106 710603102 711003105 711303104 711603103 712003106 weight [g] 377 377 377 377 377 367 367 367 367 367 367 393 393 393 packaging [pcs] 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 weight [g] 500 500 500 500 500 488 488 488 488 488 488 524 524 524 packaging [pcs] 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 weight [g] 124 124 124 124 124 121 121 121 121 packaging [pcs] 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 Miniature circuit breaker ETIMAT 11-QC Rated short-circuit capacity 10 kA Rated current 0,5 - 20 A Tripping characteristic B, C, D, K 1-pole ln [A] 0,5 1 2 4 6 10 13 16 20 8 Un [V] 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 1-pole + N ln [A] 0,5 1 2 4 6 10 13 16 20 Un [V] 230 230 230 230 230 230 230 230 230 2-pole ln [A] 0,5 1 2 4 6 10 13 16 20 Un [V] 400 400 400 400 400 400 400 400 400 3-pole ln [A] 0,5 1 2 4 6 10 13 16 20 Un [V] 400 400 400 400 400 400 400 400 400 3-pole + N ln [A] 0,5 1 2 4 6 10 13 16 20 Un [V] 400 400 400 400 400 400 400 400 400 code No. B code No. C code No. D code No. K 710610106 711010109 711310108 711610107 712010100 710511104 710111102 710211105 710411101 710611107 711011100 711311109 711611108 712011101 710512105 710112103 710212106 710412102 710612108 711012101 711312100 711612109 712012102 710513106 710113104 710213107 710413103 710613109 711013102 711313101 711613100 712013103 code No. B code No. C code No. D code No. K 710620103 711020106 711320105 711620104 712020107 710521101 710121109 710221102 710421108 710621104 711021107 711321106 711621105 712021108 710522102 710122100 710222103 710422109 710622105 711022108 711322107 711622106 712022109 710523103 710123101 710223104 710423100 710623106 711023109 711323108 711623107 712023100 code No. B code No. C code No. D code No. K 710630100 711030103 711330102 711630101 712030104 710531108 710131106 710231109 710431105 710631101 711031104 711331103 711631102 712031105 710532109 710132107 710232100 710432106 710632102 711032105 711332104 711632103 712032106 710533100 710133108 710233101 710433107 710633103 711033106 711333105 711633104 712033107 code No. B code No. C code No. D code No. K 710640107 711040100 711340109 711640108 712040101 710541105 710141103 710241106 710441102 710641108 711041101 711341100 711641109 712041102 710542106 710142104 710242107 710442103 710642109 711042102 711342101 711642100 712042103 710543107 710143105 710243108 710443104 710643100 711043103 711343102 711643101 712043104 weight [g] 249 249 249 249 249 245 245 245 245 packaging [pcs] 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 weight [g] 249 249 249 249 249 245 245 245 245 packaging [pcs] 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 weight [g] 377 377 377 377 377 367 367 367 367 packaging [pcs] 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 weight [g] 500 500 50 500 500 488 488 488 488 packaging [pcs] 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 PRODUCT LINE E11 Miniature circuit breakers 9 PRODUCT LINE E11 Miniature circuit breakers Miniature circuit breaker ETIMAT RC (remote control) Rated short-circuit capacity 10 kA Rated current 6 - 63 A Tripping characteristics B, C 1-pole ln [A] 6 10 13 16 20 25 32 40 50 63 10 Un [V] 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 1-pole + N ln [A] 6 10 13 16 20 25 32 40 50 63 Un [V] 230 230 230 230 230 230 230 230 230 230 2-pole ln [A] 6 10 13 16 20 25 32 40 50 63 Un [V] 400 400 400 400 400 400 400 400 400 400 3-pole ln [A] 6 10 13 16 20 25 32 40 50 63 Un [V] 400 400 400 400 400 400 400 400 400 400 code No. B code No. C 630600100 631000103 631300102 631600101 632000104 632500109 633200101 634000106 635000107 636300107 630601101 631001104 631301103 631601102 632001105 632501100 633201102 634001107 635001108 636301108 code No. B code No. C 630610107 631010100 631310109 631610108 632010101 632510106 633210108 634010102 635010103 636310103 630611108 631011101 631311100 631611109 632011102 632511107 633211109 634011103 635011104 636311104 code No. B code No. C 630620104 631020107 631320106 631620105 632020108 632520103 633220105 634020100 635020101 636320101 630621105 631021108 631321107 631621106 632021109 632521104 633221106 634021101 635021102 636321102 code No. B code No. C 630630101 631030104 631330103 631630102 632030105 632530100 633230102 634030107 635030108 636330108 630631102 631031105 631331104 631631103 632031106 632531101 633231103 634031108 635031109 636331109 weight [g] 124 121 121 121 121 121 121 130 130 130 packaging [pcs] 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 weight [g] 249 245 245 245 245 245 245 261 261 261 packaging [pcs] 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 weight [g] 249 245 245 245 245 245 245 261 261 261 packaging [pcs] 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 weight [g] 377 367 367 367 367 367 367 393 393 393 packaging [pcs] 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 3-pole + N ln [A] 6 10 13 16 20 25 32 40 50 63 Un [V] 400 400 400 400 400 400 400 400 400 400 code No. B code No. C 630640108 631040101 631340100 631640109 632040102 632540107 633240109 634040104 635040105 636340105 700641109 701041102 701341101 701641100 702041103 702541108 703241100 704041105 705041106 706341106 weight [g] 500 488 488 488 488 488 488 524 524 524 PRODUCT LINE E11 Miniature circuit breakers packaging [pcs] 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 3/15 Miniature circuit breaker ETIMAT11-DC Rated short-circuit capacity 6 kA Rated current 6 - 63 A 1-pole ln [A] 6 10 13 16 20 25 32 40 50 63 Un [V] 220 220 220 220 220 220 220 220 220 220 2-pole ln [A] 6 10 13 16 20 25 32 40 50 63 Un [V] 440 440 440 440 440 440 440 440 440 440 Tripping characteristic B, C code No. B code No. C 690600102 691000105 691300104 691600103 692000106 692500101 693200103 694000108 695000109 696300109 690601106 691001109 691301108 691601107 692001100 692501105 693201107 694001102 695001103 696301103 code No. B code No. C 690620106 691020109 691320108 691620107 692020100 692520105 693220107 694020102 695020103 696320103 690621107 691021100 691321109 691621108 692021101 692521106 693221108 694021103 695021104 696321104 weight [g] 124 245 245 245 245 245 245 261 261 261 packaging [pcs] 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 weight [g] 249 245 245 245 245 245 245 261 261 261 packaging [pcs] 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 6/30 Accessories for ETIMAT11, ETIMAT11-QC and ETIMAT11-DC PS/SS E11 is an auxiliary switch used for remote signalling of the MCB to which it is fixed. PS/SS E11 may also be fixed later of the state. Clamps are safe to touch. External dimensions comply with MCB, built-in width is 0,5 module (9 mm). During fitting, the MCB must be switched off. Auxiliary switch PS/SS E11 type code No. PS/SS E11 768900101 contacts 1xNC, 1xNC/NO weight [g] 40 packaging [pcs] 1/10 11 PRODUCT LINE E11 Miniature circuit breakers DA ETIMAT11 shunt trip release is fixed to the right side of the miniature circuit breaker ETIMAT11 for remote release of the MCB. Dimensions correspond to those of MCB ETIMAT11. Shunt trip release DA ETIMAT 11 type code No. DA ETIMAT11 12-60V AC/DC DA ETIMAT11 110-250V AC 770610108 772510107 weight [g] 110 110 packaging [pcs] 1/54 1/54 weight [g] 231 231 231 packaging [pcs] 2/72 2/72 2/72 weight [g] 466 466 466 packaging [pcs] 1/36 1/36 1/36 weight [g] 696 696 696 packaging [pcs] 1/18 1/18 1/18 weight [g] 860 860 860 packaging [pcs] 1/18 1/18 1/18 Miniature circuit breaker ETIMAT11 80 -125A Rated short-circuit capacity 15, 20 kA Rated current 80 - 125 A Tripping characteristics C, D 1-pole ln [A] 80 100 125 2-pole ln [A] 80 100 125 3-pole ln [A] 80 100 125 3-pole + N ln [A] 80 100 125 12 code No. C code No. D 002131731 002131732 002131733 002151731 002151732 code No. C code No. D 002133731 002133732 002133733 002153731 002153732 code No. C code No. D 002135731 002135732 002135733 002155731 002155732 code No. C code No. D 002136731 002136732 002136733 002156731 002156732 PRODUCT LINE E11 Miniature circuit breakers Accessories for ETIMAT11 80 - 125A Shunt trip release DA ETIMAT 80/125 110 - 415V code No. B weight packaging [g] [pcs] 002159321 173 1/54 Auxiliary switch PSM 80/125 code No. B weight [g] 002159121 62 packaging [pcs] 1/12 Current limiter OSP-11 Rated short-circuit capacity 10 kA 1-pole ln [A] 6 10 13 16 20 25 32 40 50 63 3-pole ln [A] 6 10 13 16 20 25 32 40 50 63 Rated current 6 - 63 A code No. 700603992 701003995 701303994 701603993 702003996 702503991 703203993 704003998 705003999 706303999 code No. 700633993 701033996 701333995 701633994 702033997 702533992 703233994 704033999 705033990 706333990 Tripping characteristics Test current Tripping time t > 3600 s 1,1 x In 2 < t < 900 s 1,4 x In 0,5 < t < 60 s 2,5 x In t > 0,1 s 10 x In t < 0,1 s 20 x In Rated voltage 230/400 V weight [g] 124 121 121 121 121 121 121 130 130 130 packaging [pcs] 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 12/60 weight [g] 377 367 367 367 367 367 367 393 393 393 packaging [pcs] 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 Application <Limiting the consumption of electric power based on current overload <Protection against short circuit. Dimensions <A single pole device (width 1 module) – dimensions fit circuit breaker ETIMAT 11 <Three-pole device: width of 3 modules Built-in <Domestic distribution boards (built-in and surface-mounted), it is possible to seal the connecting terminals with special sealing peace. <Surface-mounted distribution board NE 2 (distribution board width: 2 moduls) for a single pole device <Surface-mounted distribution board NE 4 (distribution board width: 4 moduls) for three pole device <Sealing available for both NE 2 and NE 4. Result No tripping Tripping Tripping No tripping Tripping 13 PRODUCT LINE E11 Residual current circuit breakers Residual current circuit breakers Residual current circuit breakers EFI are used for protection against indirect touching of parts under voltage, for prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of I∆n≤30mA. Residual current circuit breakers can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective conductor are separated (VDE 0100 Part 410). Types - Our programme comprises residual current circuit breakers which are sensitive to alternating residual current (AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type). type A EFI 2 EFI 4 type type type type type type type type AC G UT A AC S G UT For alternating residual current For alternating and pulsating direct residual current Short-circuit capacity with back-up fuse lower temperature limit of application -25°C VDE 0664, part 1 (up to 80 A) Selective (time delayed min. 40 ms) Short time delayed (min. 10 ms) UT Unwanted tripping Note: Tripping time according to standard IEC 61008 Residual current circuit breaker EFI-2 Rated residual current 0,03 - 0,5 A Rated current 16 - 80 A type A, AC, G EFI-2 type A, EFI-2 type AC number ln l∆n [A] [A] of poles 16 0,03 2 25 0,03 2 40 0,03 2 63 0,03 2 80 0,03 2 16 0,1 2 25 0,1 2 40 0,1 2 63 0,1 2 80 0,1 2 16 0,3 2 25 0,3 2 40 0,3 2 63 0,3 2 80 0,3 2 16 0,5 2 25 0,5 2 40 0,5 2 63 0,5 2 80 0,5 2 14 code No. A code No. AC 002062521 002062522 002062523 002062524 002062525 002063521 002063522 002063523 002063524 002063525 002064521 002064522 002064523 002064524 002064525 002065521 002065522 002065523 002065524 002065525 002062121 002062122 002062123 002062124 002062125 002063121 002063122 002063123 002063124 002063125 002064121 002064122 002064123 002064124 002064125 002065121 002065122 002065123 002065124 002065125 weight [g] 229 229 229 244 244 223 223 223 227 230 223 223 223 227 230 223 223 223 227 230 packaging [pcs] 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 PRODUCT LINE E11 Residual current circuit breakers Residual current circuit breaker EFI-4 Rated residual current 0,03 - 0,5 A Rated current 16 - 80 A type A, AC EFI-4 type A, EFI-4 type AC number code No. A ln l∆n [A] [A] of poles 16 0,03 4 002062541 25 0,03 4 002062542 40 0,03 4 002062543 63 0,03 4 002062544 80 0,03 4 002062545 16 0,1 4 002063541 25 0,1 4 002063542 40 0,1 4 002063543 63 0,1 4 002063544 80 0,1 4 002063545 16 0,3 4 002064541 25 0,3 4 002064542 40 0,3 4 002064543 63 0,3 4 002064544 80 0,3 4 002064545 16 0,5 4 002065541 25 0,5 4 002065542 40 0,5 4 002065543 63 0,5 4 002065544 80 0,5 4 002065545 * type with N-pole on the left side is also available. code No. AC 002062141 002062142 002062143 002062144 002062145 002063141 002063142 002063143 002063144 002063145 002064141 002064142 002064143 002064144 002064145 002065141 002065142 002065143 002065144 002065145 weight [g] 393 393 393 400 407 393 393 393 400 407 364 364 364 372 372 364 364 364 372 372 packaging [pcs] 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 Accessories for residual current circuit breakers EFI (16 - 80 A) The PS EFI is fixed to EFI series switches. The width of the device is 9 mm, other dimensions are in compliance with EFI switches. The auxiliary switch PS EFI is used for the remote signalling of the state of contact’s condition (close/open) of EFI switches. During fitting, the EFI must be switched off. Auxiliary Switch PS EFI type contact code No. PS EFI - MD b-contact/a-contact PS EFI - 2M 2 x b-contact PS EFI - 2D 2 x a-contact a - contact = make contact (NO) b - contact = break contact (NC) 002069001 002069002 002069003 Sealing piece EFI-2 code No. weight [g] 002069011 2 packaging [pcs] 2 Sealing piece EFI-4 code No. weight [g] 002069012 3 packaging [pcs] 2 weight [g] 50 50 50 packaging [pcs] 1/12 1/12 1/12 15 PRODUCT LINE E11 Residual current circuit breakers Residual current circuit breaker EFI-2 100 Rated residual current 0,03 - 0,3 A Rated current 100 A type A, AC EFI-2 100 ln [A] 100 100 100 type A, EFI-2 100 type AC number code No. A l∆n [A] of poles 0,03 2 002062530 0,1 2 002062532 0,3 2 002062534 code No. AC 002062531 002062533 002062535 weight [g] 400 400 400 packaging [pcs] 1/27 1/27 1/27 weight [g] 320 320 320 packaging [pcs] 1/27 1/27 1/27 Residual current circuit breaker EFI-4 100 Rated residual current 0,03 - 0,3 A Rated current 100 A type A, AC EFI-4 100 ln [A] 100 100 100 type A, EFI-4 100 type AC number code No. A l∆n [A] of poles 0,03 4 002062150 0,1 4 002062152 0,3 4 002062154 code No. AC 002062151 002062153 002062155 Residual current circuit breaker EFI-2 UT Rated residual current 0,03 A Rated current 25 A type A EFI-2 UT type A ln l∆n [A] [A] 25 0,03 number of poles 2 code No. A 852528418 weight [g] 260 packaging [pcs] 1/10 weight [g] 453 453 470 470 470 470 470 470 470 packaging [pcs] 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 Residual current circuit breaker EFI-4 UT Rated residual current 0,03 - 0,5 A Rated current 25 -63 A type A EFI-4 UT type A ln l∆n [A] [A] 25 0,03 40 0,03 63 0,03 40 0,1 63 0,1 40 0,3 63 0,3 40 0,5 63 0,5 16 number of poles 4 4 4 4 4 4 4 4 4 code No. A 852548411 854048418 856348419 854041411 856341412 854043413 856343414 854045415 856345416 PRODUCT LINE E11 Residual current circuit breakers Residual current circuit breaker EFI-4 S Rated residual current 0,3 A Rated current 40 - 63 A type A, AC EFI-4 S type A, EFI-4 S type AC number code No. A ln l∆n [A] [A] of poles 40 0,3 4 859443410 63 0,3 4 859643416 code No. AC weight [g] 400 400 002064243 002064244 packaging [pcs] 1/27 1/27 Residual current circuit breaker EFI-4 KV/G Rated residual current 0,03 A Rated current 40 A EFI-4 KV/G type A number ln l∆n [A] [A] of poles 40 0,03 4 type A code No. A 854088416 weight [g] 400 packaging [pcs] 1/27 Accessories for residual current circuit breakers EFI UT, EFI S, EFI KV/G PS/SS is an auxiliary switch used for remote signalling of the MCB to which it is fixed. PS/SS may also be fixed later of the state. Clamps are safe to touch. External dimensions comply with EFI, built-in width is 0,5 module (9 mm). During fitting, the EFI must be switched off. Auxiliary switch PS/SS type code No. contacts PS/SS 769900102 1xNC, 1xNC/NO weight [g] 40 packaging [pcs] 1/10 17 PRODUCT LINE E11 Residual current circuit breakers with integral overcurrent protection Residual current circuit breakers with integral overcurrent protection Residual current circuit breaker with integral overcurrent protection KZS-2M Rated short-circuit capacity 10 kA Rated current 6 - 40 A Tripping characteristic B, C Rated residual current 0,01 - 0,03 - 0,3 A Description: KZS (KZS-2M, KZS-3M, KZS-4M 3p, KZS-4M 3p+N and KZS-2M UT) is a residual current circuit breaker combining the features of a miniature circuit-breaker and a residual current circuit breaker and is functionally independent on line voltage. Used primarily in circuits with an increased requirements regarding touch voltage such circuits of portable appliances, in kindergartens, schools and hospitals etc. 18 KZS-2M ln [A] 6 10 13 16 20 25 32 40 IΔn = 30 mA type A code No. B code No. C 002173201 002173221 002173202 002173222 002173203 002173223 002173204 002173224 002173205 002173225 002173206 002173226 002173207 002173227 002173208 002173228 type AC code No. B code No. C 002173101 002173121 002173102 002173122 002173103 002173123 002173104 002173124 002173105 002173125 002173106 002173126 002173107 002173127 002173108 002173128 KZS-2M ln [A] 6 10 13 16 20 25 32 40 IΔn = 300 mA type AC code No. B code No. C 002173301 002173321 002173302 002173322 002173303 002173323 002173304 002173324 002173305 002173325 002173306 002173326 002173307 002173327 002173308 002173328 packaging [pcs] 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 KZS-2M ln [A] 6 10 13 16 IΔn = 10 mA type A code No. B code No. C 002173211 002173231 002173212 002173232 002173213 002173233 002173214 002173234 packaging [pcs] 1/54 1/54 1/54 1/54 packaging [pcs] 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 PRODUCT LINE E11 Residual current circuit breakers with integral overcurrent protection Residual current circuit breaker with integral overcurrent protection KZS-3M Rated short-circuit capacity 10 kA KZS-3M ln [A] 6 10 13 16 20 25 Rated current 6 - 25 A Tripping characteristic B, C IΔn = 30 mA type A code No. B code No. C 002173801 002173821 002173802 002173822 002173803 002173823 002173804 002173824 002173805 002173825 002173806 002173826 Rated residual current 0,03 A packaging [pcs] 1/36 1/36 1/36 1/36 1/36 1/36 Residual current circuit breaker with integral overcurrent protection KZS-4M 3p Rated short-circuit capacity 10 kA Rated current 6 - 32 A Tripping characteristic B, C Rated residual current 0,03 A NEW! KZS-4M 3p IΔn = 30 mA type A ln [A] code No. B code No. C 6 002174701 002174721 10 002174702 002174722 13 002174703 002174723 16 002174704 002174724 20 002174705 002174725 25 002174706 002174726 32 002174707 002174727 type AC code No. B code No. C 002174801 002174821 002174802 002174822 002174803 002174823 002174804 002174824 002174805 002174825 002174806 002174826 002174807 002174827 weight [g] 478 478 478 478 478 478 478 packaging [pcs] 1/27 1/27 1/27 1/27 1/27 1/27 1/27 Residual current circuit breaker with integral overcurrent protection KZS-4M 3p+N Rated short-circuit capacity 10 kA Rated current 6 - 32 A Tripping characteristic B, C Rated residual current 0,03 A NEW! KZS-4M 3p+N IΔn = 30 mA type A ln [A] code No. B code No. C 6 002174901 002174921 10 002174902 002174922 13 002174903 002174923 16 002174904 002174924 20 002174905 002174925 25 002174906 002174926 32 002174907 002174927 type AC code No. B code No. C 002174001 002174021 002174002 002174022 002174003 002174023 002174004 002174024 002174005 002174025 002174006 002174026 002174007 002174027 weight [g] 478 478 478 478 478 478 478 packaging [pcs] 1/27 1/27 1/27 1/27 1/27 1/27 1/27 Residual current circuit breaker with integral overcurrent protection KZS-2M UT Rated short-circuit capacity 10 kA Rated current 16 A KZS-2M UT IΔn = 30 mA type A ln [A] code No. B code No. C 16 741615323 741616324 Tripping characteristic B, C weight [g] 290 Rated residual current 0,03 A packaging [pcs] 1/10 19 PRODUCT LINE E11 Build-in switch Accessories for residual current circuit breaker with integral overcurrent protection KZS-2M UT PS/SS is an auxiliary switch used for remote signalling of the MCB to which it is fixed. PS/SS may also be fixed later of the state. Clamps are safe to touch. External dimensions comply with KZS-2M UT, built-in width is 0,5 module (9 mm). During fitting, the KZS-2M UT must be switched off. Auxiliary switch PS/SS type code No. contacts PS/SS 769900102 1xNC, 1xNC/NO weight [g] 40 packaging [pcs] 1/10 Build-in switch Build-in switch SV Rated current 100 A Utilization category AC-22B Application Build-in switch is used as a main switch in distribution boxes in houses or as a switch for individual electric circuits. With a build-in switch we can completely replace the cam switch. Build-in switch can be sealed either in ON or OFF position. Advantages Build-in switch has a more robust and simple construction and therefore a more reliable operation. It also shows the status of the contacts. With an additional label the circuit in which the switch is built in can be marked. Switches with In≤ 63A have a double switching OFF. 1-pole type SV 1100 2-pole type SV 2100 3-pole type SV 3100 20 In code No. Un [A] 100 002423116 [V] 230/400 In code No. Un [A] 100 002423216 [V] 400 In code No. Un [A] 100 002423316 [V] 400 utilization category AC-22B utilization category AC-22B utilization category AC-22B weight packaging [g] 90 [pcs] 12/108 weight packaging [g] 180 [pcs] 6/54 weight packaging [g] 270 [pcs] 4/36 4-pole type SV 4100 In code No. Un [A] 100 002423416 [V] 400 utilization category AC-22B weight packaging [g] 360 [pcs] 3/27 PRODUCT LINE E11 Build-in switch 21 ETI Elektroelement d.d. Obrezija 5, SI - 1411 Izlake Slovenia Phone: + 386 03 56 57 570 Fax: + 386 03 56 74 077 eti@eti.si www.etigroup.eu