ASTI Residual current circuit breakers 3-polni ln [A] 6 10 13 16 20 25 32 40 50 63 code No. 700633993 701033996 701333995 701633994 702033997 702533992 703233994 704033999 705033990 706333990 weight [g] 377 367 367 367 367 367 367 393 393 393 packaging [pcs] 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 4/20 Tripping characteristics Test current Tripping time 1,1 x In t > 3600 s 2 < t < 900 s 1,4 x In 0,5 < t < 60 s 2,5 x In t > 0,1 s 10 x In t < 0,1 s 20 x In Result No tripping Tripping Tripping No tripping Tripping Application <Limiting the consumption of electric power based on current overload <Protection against short circuit. Dimensions <A single pole device (width 1 module) – dimensions fit circuit breaker ETIMAT 11 <Three-pole device: width of 3 modules Built-in <Domestic distribution boards (built-in and surface-mounted), it is possible to seal the connecting terminals with special sealing peace. <Surface-mounted distribution board NE 2 (distribution board width: 2 moduls) for a single pole device <Surface-mounted distribution board NE 4 (distribution board width: 4 moduls) for three pole device <Sealing available for both NE 2 and NE 4. Residual current circuit breakers Residual current circuit breakers EFI are used for protection against indirect touching of parts under voltage, for prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of I∆n≤30mA. Residual current circuit breakers can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective conductor are separated (VDE 0100 Part 410). Types - Our programme comprises residual current circuit breakers which are sensitive to alternating residual current (AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type). EFI 2 type A type AC type G EFI 4 type A type AC type S type G For alternating residual current For alternating and pulsating direct residual current Short-circuit capacity with back-up fuse lower temperature limit of application -25°C VDE 0664, part 1 (up to 80 A) Selective (time delayed min. 40 ms) Short time delayed (min. 10 ms) Note: Tripping time according to standard IEC 61008 24 technical data on page 251 Residual current circuit breakers Nazivniresidual Rated diferenčni current tok 0,03 - 0,5 A Nazivnicurrent Rated tok 16 - 80 A ASTI Residual current circuit breaker EFI-2 Tip Type A, AC, G EFI-2 type A, EFI-2 type AC ln number l∆n [A] [A] of poles 16 0,03 2 25 0,03 2 40 0,03 2 63 0,03 2 80 0,03 2 100 0,03 2 16 0,1 2 25 0,1 2 40 0,1 2 63 0,1 2 80 0,1 2 100 0,1 2 16 0,3 2 25 0,3 2 40 0,3 2 63 0,3 2 80 0,3 2 100 0,3 2 16 0,5 2 25 0,5 2 40 0,5 2 63 0,5 2 80 0,5 2 code No. A code No. AC 002062521 002062522 002062523 002062524 002062525 002062530 002063521 002063522 002063523 002063524 002063525 002062532 002064521 002064522 002064523 002064524 002064525 002062534 002065521 002065522 002065523 002065524 002065525 002062121 002062122 002062123 002062124 002062125 002062531 002063121 002063122 002063123 002063124 002063125 002062533 002064121 002064122 002064123 002064124 002064125 002062535 002065121 002065122 002065123 002065124 002065125 weight [g] 229 229 229 244 244 244 223 223 223 227 230 230 223 223 223 227 230 230 223 223 223 227 230 packaging [pcs] 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 1/54 16 - 80 A 100 A Residual current circuit breaker EFI-4 Rated residual current 0,03 - 0,5 A Rated current 16 - 80 A type A, AC EFI-4 type A, EFI-4 type AC ln number code No. A l∆n of poles [A] [A] 16 0,03 4 002062541 25 0,03 4 002062542 40 0,03 4 002062543 63 0,03 4 002062544 80 0,03 4 002062545 100 0,03 4 002062150 16 0,1 4 002063541 25 0,1 4 002063542 40 0,1 4 002063543 63 0,1 4 002063544 80 0,1 4 002063545 100 0,1 4 002062152 16 0,3 4 002064541 25 0,3 4 002064542 40 0,3 4 002064543 63 0,3 4 002064544 80 0,3 4 002064545 100 0,3 4 002062154 16 0,5 4 002065541 25 0,5 4 002065542 40 0,5 4 002065543 63 0,5 4 002065544 80 0,5 4 002065545 * Na voljo je tudi izvedba s polom N na levi strani. code No. AC 002062141 002062142 002062143 002062144 002062145 002062151 002063141 002063142 002063143 002063144 002063145 002062153 002064141 002064142 002064143 002064144 002064145 002062155 002065141 002065142 002065143 002065144 002065145 weight [g] 393 393 393 400 407 407 393 393 393 400 407 407 364 364 364 372 372 372 364 364 364 372 372 packaging [pcs] 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 1/27 16 - 80 A 100 A technical data on page 251 25 ASTI Residualcurrentcircuitbreakers EFI-4 tip S ln [A] 40 63 l∆n [A] 0,3 0,3 number of poles 4 4 EFI-4 tip G ln l∆n [A] [A] 40 0,03 number of poles 4 code No. A code No. AC 859443410 859643416 002064243 002064244 code No. AC weight [g] 320 854088416 weight [g] 400 400 packaging [pcs] 1/10 1/10 packaging [pcs] 1/10 ETIalsomanufacturestrippingrelaysusedinresidualcurrentcircuitbreakers–therangeof productsandtheirtechnicaldataisavailableintechnicalinformationpublishedseparately. AccessoriesforresidualcurrentcircuitbreakersEFI(16-80A) ThePSEFIisfixedtoEFIseriesswitches.The switches.TheauxiliaryswitchPSEFIisusedfortheremotesignallingofthestateofcontact’scondition(closed/open)of EFIswitches.Duringfitting,theEFImustbeswitchedoff. Auxiliary Switch PS EFI type contact code No. PS EFI - MD b-contact/a-contact PS EFI - 2M 2 x b-contact PS EFI - 2D 2 x a-contact a - contact = make contact (NO) b - contact = break contact (NC) 002069001 002069002 002069003 Sealing piece EFI-2 code No. weight [g] 002069011 2 packaging [pcs] 2 Sealing piece EFI-4 code No. weight [g] 002069012 3 packaging [pcs] 2 Shunt trip release DA EFI tip code No. 002069004 26 weight [g] 45 weight [g] 50 50 50 packaging [pcs] 1/12 1/12 1/12 packaging [pcs] 1/12 technicaldataonpage