Metal Enclosed Switchgears
Metal Clad Switchgears
Gas Insulated RMU's
Catalogue 2011
a Friem & Aktif Group Company
Aktif trade mark for Medium voltage switchgears, Switching equipment and
Kiosks with high quality and environmentally sensitive
Competitive trade mark of Aktif for manufacturing Medium voltage
switchgears, Switching equipment and kiosks
Aktif trade mark for Capacitor Banks, Harmonic Filters, Resistors, Medical
Insulated Power Panels, Synchronization and Energy automation Panels
with high quality and environmentally sensitive
Aktif trade mark for Measuring, Protection, Automatic Meter Reading,
Billing and Energy Management Software.
Aktif trade mark for Measuring, Protection, Control and Power Quality products
with high quality, long life and environmentally sensitive
Identifies the product as top quality, safe and one step forward of the similar ones.
Symbolizes measurable energy saving products helps to energy continuity.
Identifies smart control logic.
Identifies easy to use products, simplifies the difficult tasks.
Green products, respects to the nature and our future.
TECHNICAL SPECIFICATIONS
A1
A2
A3
A4
A5
A6
Partition Specification
Internal Arc Classification (IAC)
Loss of Service Continuity (LSC)
Insulation of Switchgears
Comparison Table
Related Standards
8
8
9
9
10
10
METAL ENCLOSED SWITCHGEARS
B1
B2
B3
B4
B5
B6
Compartments
Application Areas
Advantages
Standards Complied
Technical Specifications
Switchgears Types
15
16
16
16
17
18
METAL CLAD SWITCHGEARS
C 1 Metal Clad Switchgears
C 1.1 Compartments
C 1.2 Application Areas
C 1.3 Advantages
C 1.4 Standards Complied
C 1.5 Technical Specifications
C 1.6 Switchgears Types
C 2 Metal Clad Switchgears for Double Busbar applications
C 2.1 Compartments
C 2.2 Application Areas
C 2.3 Advantages
C 2.4 Standards Complied
C 2.5 Technical Specifications
C 2.6 Switchgears Types
38
39
41
41
41
42
43
52
52
53
53
54
54
55
GAS INSULATED RMUs
D1
D2
D3
D4
D5
D6
D7
Compartments
Application Areas
Advantages
Standards Complied
Technical Specifications
Switchgears Types
Sample Busbar Designs with RMU Units
63
63
64
64
65
67
78
AUXILIARY EQUIPMENT
E 1 Switching Equipment
E 2 Protection Devices
E 3 Measuring Devices
E 4 Measuring Transformers
82
86
89
93
1
Company Profile
Aktif Mühendislik Ltd.
Aktif Engineering (AMDT) is established in 1996
Measuring, Protecting and Quality of Electricity.
2200m2 headquarter of AMDT is located in Istanbul
consisting of 35 employees. Since establishment AMDT
provides high quality engineering, supplying and start-up
services for the power quality, energy saving, energy
metering, protection.
AMDT provides standard and custom designed solutions
to domestic and international customers, with over 15
years of experience.
Aktif Raylı Sistemler Ltd.
Aktif Railway Systems (ARS) is established in 2008 for the
designing and providing of traction systems' substations
as well as providing on-board equipment used on vehicles.
The main purpose of ARS is providing engineering services
and products to public bodies and companies in this
sector.
Even though it is a brand new company, ARS managed to
complete successfully both Antalya Light Rail System
project as well as Istanbul Metro Stinger System projects.
Aksis Enerji Sistemleri Ltd.
Aksis Energy Metering Systems (AKS) is established in
2003 for providing metering solutions like Automatic Meter
Reading, Billing Software in every level of energy sector.
The company is focused on saving and efficient using of
energy by its Meter Management and Loss & Leakage
tracing solutions.
AKS answers all expectations in power systems with high
quality products and custom design software solutions.
AKS customers create over 100 million Euro energy bills
using different Metering, Management and Billing methods
of AKS.
2
Company Profile
Aktif Elektroteknik A.Ş.
The company is established to manufacture Switchgears and
Kiosks under the name of “Setas” in 1981. First in 2008,
company merged to Aktif Group as Aktif Elektroteknik (AET)
and then the company becomes international after significant
participation of Italian Friem S.p.A in 2009.
9000m2 factory of AET is located in Ankara consisting of over
100 employees.
AET operates with its 30 years of manufacturing experience,
modernized machinery line, ever increasing know-how,
experienced Turkish and Italian R&D teams, quality products
type tested by the leading accredited European laboratories
and the vision of new ideas to meet with future expectations.
Friem S.p.A.
Friem manufactured over 40 million ampere and 1000 power
rectifiers for the worldwide since it's established in Milan at
1950.
Having technical knowledge of energy and electro mechanics
along with ability of complete design of conversion systems,
FRIEM provides also high voltage DC insulators, DC switches,
anodic control and protection products and auxiliary equipments
like polarization products to its customers.
Friem is a share holder of Aktif Elektronik in Turkey and also
COET S.r.L in Italy.
Coet S.r.L.
Since establishment in 1962 in Milan, COET has been
producing AC/DC switching equipments and panels that are
used safely by its customers thanks to the COET's work on
industrial and electric equipment and patents obtained in this
field.
All manufactured products are the result of long technical
research and development work. This way, the company is
known for the originality and diversity of its planned solutions.
COET has been working on Industrial and railway systems
and has become one of the leading companies in the field of
supplying switching equipments for traction substation.
3
Company Profile
Introduction
Aktif Group is in continuous development with its
customer oriented activities, advanced engineering
know-how, R&D works, software developing abilities and
with the continuous support of loyal customers that are
attained and protected by precise work and ethical
principles of the company.
The group companies have ISO 9001 since 90s and our
factory has ISO 14001 Environment and ISO 18001
Occupational Health and Safety Certificates.
Technology
The most important activities of Aktif is R&D and increase the
Employee quality which the investment amount of these
activities are more than average.
All mechanical projects are designed by 3D-CAD platforms.
Power flow, test and quality works are calculated by
Worldwide accepted simulation software and ActWin software
as well as developing software for different platforms.
In order to increase the production quality and capacity all
machinery within the facility are renewed with latest
technology equipment in 2009.
Mission
By the help of our following missions are continuing to
announce product quality and knowledge of our company
and country in best possible way by meeting rising
customer expectations.
open minded approach
high quality policy
innovative ideas
constantly improved processes
polished employees
knowledge based decisions
Vision
To increase the number of our loyal customers in global
market, hence increasing the market share and
becoming reputable, reliable and preferred company as
worldwide with our;
prominent quality difference,
customer oriented approach,
innovative activities,
open minded approach.
4
Company Profile
Security
The human safety and security are the main concerns in
all of our products.
Design, Interlock logics and documentation of our
products are implemented, manufactured and tested in
order to reach the highest safety level.
Furthermore, services and site works are done according
to human safety rules by taking into account the
dangerous of electricity.
High Performance, Durable and Simple
Endurance of our products, which are produced with high
level of awareness and accurateness in addition to follow
international standards, ensures an outstanding
performance for the users. Therefore our products are
considered as top of the line products.
Visual simplicity and being user friendly are the design
criteria for the software and hardware of our products. Our
products have the most simple and functional features for
emergency applications as well as persistence of habits and
customer satisfaction are basics in design, production and
shipment.
Service Continuity
The service continuity means efficiency of power
consequently profitability of the business.
Our products are designed and manufactured in order to
ensure energy sustainability and provide the best service
availability.
This policy is the cornerstone of our orientation and training
programs and it is fully applied by our technical and
administrative staff.
Local & Remote Monitoring
Energy continuity and efficiency can be ensured only by
monitoring of equipments local and remotely.
Our products are designed with remote monitoring and
management features by the help of our software
development abilities on different platforms and hardware
capabilities. This will ensure the saving and profitability,
directly.
5
A 1 Partition Specification
A 1.1 Accessible Compartments
A 1.2 Non-accessible Compartments
A 1.3 Partition Class
A 2 Internal Arc Classification (IAC)
A 3 Loss of Service Continuity (LSC)
A 4 Insulation of Switchgears
A 5 Comparison Table
A 6 Related Standards
8
8
8
8
9
9
10
10
11
6
Technical
Information
A
Technical Information
Metal Enclosed switching and control equipment between
the rated voltage 1 - 52 kVac are defined in IEC 62271-200
standards.
Medium
Voltage
Switchgears
Partition
Specifications
Internal
Arc
Classification
Loss of
Service
Continuity
Accessible
Compartments
Non-accessible
Compartments
Partition
Class
It is possible to classify the Switchgears in accordance with
the specifications given in IEC 62271-200 standard
conveniently in the below given table.
Insulation of
Compartments
A 1 Partition Specifications
The structure of the switchgears partitions and their features
are provided in 3 main headings as seen in the attached table.
A 1.1 Accessible Compartments
Interlock-controlled accessible compartment: Compartment
containing high voltage parts, intended to be opened for
normal operation and/or normal maintenance as stated by
the manufacturer, in which Access is controlled by integral
design of the switchgear and controlgear. Installation,
extension, repairing are not considered as normal
maintenance
Switchgears classification according to IEC 62271-200
Procedure-based accessible compartments: Compartments
containing high-voltage parts, intended to be opened for
normal operation and/or normal maintenance as stated by
the manufacturer, in which Access is controlled by suitable
procedure combined with locking. Installation, extension,
repairing are not considered as normal maintenance
Tool based accessible compartments: Compartment
containing high-voltage parts, that may be opened, but not
for normal operation and maintenance. Special procedures
are required. Tools are necessary for opening.
A 1.2 Non-accessible Compartments
Compartments that should not be needed to open and the
opening may damage the integrity which contains high-voltage.
A 1.3 Partition Class
It is a classification that defines whether metallic or
non-metallic parts to be used or not for the purpose of
segregating the compartments contains live parts.
8
a Friem & Aktif Group Company
Partition class PM
Switchgear providing continuous
metallic partitions and/or shutters,
intended to be earthed, between
opened accessible compartments
and live parts of the main circuits
Partition class PI
Switchgear having one or more nonmetallic partitions or shutters
between opened accessible
compartments and live parts of the
main circuit
Technical Information
A 2 Internal Arc Classification
It is a classification for metal enclosed switchgear and
controlgear, to ensure that in case of an internal arc the
defined conditions for protecting people are met and verified
by the appropriate test.
Three types of accessibility are defined, by considering
possible accessibility of Switchgears at site.
Accessibility Type A: Restricted to the authorized
personal only
Accessibility Type B: Unrestricted accessibility, open
to any people
Accessibility Type C: Accessibility restricted by
installation which is out of
reachable distance for pole
mounted switchgears. The
allowable minimum height of the
facility should be defined by the
manufacturer.
The metal enclosed switchgear and controlgear may have
different accessibilities for different directions. The following
codes should be used to define accessibility from different
directions.
F : Front
L : Side
R : Back
A 3 Loss of Service Continuity
It is a classification which defines the keeping of other
Switchgears and/or functional units in energizing position
when main circuit compartment of a switchgear is opened.
LSC2: It shows the having to other accessible compartments
out of the main busbar compartment of single busbar
switchgear and controlgear. Two subsections are
defined.
LSC2B: defines the Switchgears that opening and
interfering of switching compartment is allowed
while both cable and busbar compartment is
energized.
LSC2A: defines the Switchgears that opening and
interfering of switching compartment is allowed
while only busbar compartment is energized.
LSC1: defines the Switchgears that opening and interfering of
switching compartment is not possible while any of
busbar or cable compartments is energized since cable
and current-voltage transformers are located in a single
section.
9
a Friem & Aktif Group Company
A
A
Technical Information
A 4 Insulation of Switchgear
Switchgears may have different types of insulations as
follows:
Air Insulated
Gas Insulated
Liquid Insulated
A 5 Comparison Table
Specifications
Metal Clad
Switchgears
Metal Enclosed
Switchgears
RMU Units
LSC
IAC
IP
Ur
Ir
Ik
2B-PM
AFLR
40
Up to 40.5 kV
Up to 4000 A
Up to 50 kA
2A-PI
AFL
40
Up to 40.5 kV
Up to 1250 A
Up to 25 kA
PM
AFL
67
Up to 40.5 kV
Up to 1250 A
Up to 25 kA
SMC series Metal Clad Switchgears
SME series Metal Enclosed Switchgears
TPR6 series Gas Insulates RMUs
10
a Friem & Aktif Group Company
Technical Information
A 6 Related Standards
The IEC 60298 was able to meet the standards while it was
utilized in previous years. However, due to the advancement of
the technology and developments in Switchgears designs, and
bringing the safety to the forefront, the standard was no able to
handle the power cuts of the systems as well as maintenance
needs of the users.
In the following table the new IEC 62271 standard and its
sections and corresponding old standard numbers are written
as it's published by SC17A and SC17C committees.
IEC 62271
Section
HIGH VOLTAGE SWITCHGEAR AND CONTROLGEAR
Old IEC Number
New Heading
1
Common specifications for high-voltage switchgear and controlgear standards
2
Seismic Competence for rated voltage of 72.5 kV and above
100
101
102
103
104
105
106
107
108
109
200
201
202
203
204
300
301
302
303
304
305
306
307
308
309
310
High-voltage alternating current circuit-breakers
Synthetic testing of high voltage alternating current circuit breakers
Alternating current disconnectors and earthing switches
Switches for rated voltages above 1 kV and less than 52 kV
High voltage switches for rated voltages of 52 kV and above
Alternating current switch-fuse combinations
High voltage alternating current contactors and contactor-based motor-starters
High voltage alternating current switchgear-fuse combinations
Switchgear having combined functions
Alternating-current series capacitor by-pass switches
AC metal enclosed switchgear and controlgear for rated voltages above
1 kV and up to an including 52 kV
AC insulation-enclosed switchgear and controlgear for rated voltages above
1 kV and up to an including 38 kV
High-voltage/low-voltage prefabricated substations
Gas-insulated metal enclosed switchgear for rated voltages of 72.5 kV and above
Rigid high-voltage, gas-insulated transmission lines for rated voltages of
72.5 kV and above
Guide for seismic qualification of high-voltage alternating current circuit breakers
High-voltage alternating current circuit breakers - Inductive load switching
High-voltage alternating current circuit breakers - Guide for short circuit and
switching test procedures for metal-enclosed and dead tank circuit breakers
High-voltage switchgear and controlgear - Use and handling of SF6 in high voltage
switchgear and controlgear
Additional requirements for enclosed switchgear and controlgear from
1 kV to 72.5 kV to be used in severe climatic conditions
Cable connections for gas-insulated metal-enclosed switchgear for
rated voltages of 72.5 kV and above - Fluid filled and extruded insulation cablesFluid-filled and dry type cable terminators
Direct connection between power transformers and gas-insulated
metal-enclosed switchgear for rated voltages of 72.5 kV and above.
High-voltage switchgear and controlgear - The use of electronic and
associated technologies in auxiliary equipment of switchgear and controlgear
Guide for asymmetrical short-circuit breaking test duty T100a
TRV parameters for high voltage switchgear and controlgear with rated value ove
1 kV and under 100 kV
Electric endurance test for circuit breakers with rated voltage of 72.5 kV and above
IEC 60694
IEC 60056
IEC 60427
IEC 60129
IEC 60265-1
IEC 60265-2
IEC 60420
IEC 60470
IEC 60298
IEC 60466
IEC 61330
IEC 60517
IEC 61640
IEC 61666
IEC 61233
IEC 61633
IEC 61634
IEC 61932
IEC 60859
IEC 61639
IEC 62063
-
11
a Friem & Aktif Group Company
A
B1
B2
B3
B4
B5
B6
Compartments
Application Areas
Advantages
Standards Complied
Technical Specifications
Switchgears Types
B 6.1 Incoming Switchgears with Disconnectors
B 6.2 Incoming Switchgears with Load Break Switch
B 6.3 Cable Connection Switchgears
B 6.4 Incoming Switchgears with Circuit Breaker
B 6.5 Outgoing Switchgears with Circuit Breaker
B 6.6 Outgoing Switchgears with Vacuum Contactor
B 6.7 Outgoing Switchgear with Fuse and Load Break Switch
B 6.8 Bus Coupling Switchgears
B 6.9 Bus Coupling Switchgears with Load Break Switch
B 6.10 Bus Section with Load Break Switch
B 6.11 Bus Section with Circuit Breaker
B 6.12 Bus Riser
B 6.13 Bus Voltage Measuring Switchgear
B 6.14 Bus Current Measuring Switchgear
B 6.15 Current & Voltage Measuring Switchgear with Load Break Switch
B 6.16 Surge Arrestor Switchgears
12
15
16
16
16
17
18
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
Metal
Enclosed
Switchgears
B
SME series Metal Enclosed Switchgears
SME series Metal Enclosed Switchgears are the switching and
control equipment between 1 kV and 40.5 kV, manufactured in
conformity with IEC 62271-200.
The first Metal Enclosed Switchgear of Turkey is manufactured
in Aktif factory in 1995 and tested in international test
laboratories.
SME series Metal Enclosed Switchgears are manufactured by
galvanized metal sheet with 2 mm thickness and painted by
electro-static powder paint in colors conforming to RAL coding.
SME series Metal Enclosed Modular Switchgears
manufactured by Aktif Elektroteknik are defined with following
features as per IEC 62271-200 standards:
Air insulated
LSC 2A Loss of Service continuity
PI Partition Class
AFL Internal Arc Classification
3 accessible compartments
14
a Friem & Aktif Group Company
SME series Metal Enclosed Switchgears
B 1 Compartments
SME series Metal Enclosed Switchgears contain
3 segregated compartments.
a
a - Low Voltage Compartment
b - Busbar Compartment
c - Switching Equipment Compartment
a - Low Voltage Compartment
b
This compartment contains all secondary circuits for
measurement, protection, control, monitoring,
communication and other associated systems.
b - Busbar Compartment
c
Busbar Compartment mainly consists of;
- Electrolytic copper busbars according to rated current.
- Epoxy resin post insulators
Access to busbar compartment is possible with special safety
procedures and tools.
c - Switching Equipment Compartment
In this Compartment following equipment is contained
according to the project specifications:
Switching equipment
Current transformers
Voltage transformers
Surge arresters
Grounding
Capacitive voltage divider
Cable connection couplings
Furthermore, this compartment also contains following
switching equipment:
SF6 Gas or vacuum circuit breaker
SF6 Gas insulated Load Break Switch
SF6 Gas insulated or Rotary Disconnector
Vacuum Contactor
Switching compartment access is controlled by integral
design of Metal Enclosed Switchgear to ensure safe
operation according to IEC 62271-200
The following mechanic Interlocks are provided as standard:
performing of Load Break switches with/without fuses is not
possible when;
the Switching compartment door is open and/or,
the Grounding disconnector is in Closed position
switching of Disconnectors used together with circuit
breakers is not possible when;
the Switching compartment door is open ,
the Circuit Breaker is Closed position and/or,
the Grounding disconnector is in Closed position
switching of Grounding disconnector is not possible when;
the Line Disconnector is in Closed position.
15
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 2 Application Areas
Metal Enclosed Switchgears are especially used in the
transformer centers, distribution systems, renewable energy
production and industrial plants where the rated current up to
1250 A and short circuit current up to 25 kA.
Energy Distribution Centers
Hydroelectric and Wind Energy Applications
Diesel and Natural Gas Power Plants
Transformer Substations
Cement Factories
Auto Industry
Petroleum and Chemical Industry
Iron and Steel Industry
Rolling Mills
Pipe lines
Shipyards
Emergency Situation and Stand-by Power Facilities
Ore Mines
Railway Substations
B 3 Advantages
LSC2A service continuity
Grounded metal separation between compartments
Maximum human safety with AFL internal arc testing feature
Safe electrical and mechanical Interlock systems do not
allow to operational faults
SF6 gas insulated Circuit breaker allows fast and easy servicing
Grounding system with ensured continuity
Modular design, which allows extension easily
Tested short time withstand current up to 25 kA / 1 s.
Interactive mimic diagram
Proven reliability with unique design
Low maintenance cost
Easy and safety operation
After sale service and spare parts availability
B 4 Standards Complied
SME series Switchgears are manufactured in conforming to
following standards:
IEC 62271-1
IEC 62271-200
IEC 62271-100
IEC 62271-102
IEC 62271-105
IEC 60044-1
IEC 60044-2
IEC 60273
IEC 60051
IEC 60255
16
a Friem & Aktif Group Company
: General articles relating to High Voltage
Switchgears
: Metal Enclosed Switchgears (1 - 52 kVac)
: Circuit Breakers (1 - 52 kVac)
: Main Circuit and grounding Disconnectors
: AC Switch and Fuse combinations
: Current Transformers
: Voltage Transformers
: Insulators
: Measuring Devices
: Secondary Protection relays
SME series Metal Enclosed Switchgears
B 5 Technical Specifications
Technical Spesifications
Descriptions
SME 3,6
Rated Voltage (rms)
Power frequency withstand voltage 50 Hz, 1 min
(rms) between phases and phase-ground
SME 12
SME 17,5
SME 24
SME 36
SME 40,5
17,5
24
36
40,5
kV
3,6
7,2
12
kV
10
20
28
38
50
70
85
40
60
75
95
125
170
185
Lightning impulse withstand voltage 1.2/50ms
kV
(peak) between phases and phase-ground
Rated frequency
Hz
Rated (rms) current of switchgears with
Busbars A
C/B and Disconnector A
Load break switches A
Vacuum Contactors (inductive switching) A
Vacuum Contactors (capacitive switching) A
Rated short time withstand (rms) current with
C/B and Disconnectors kA
Load break switches kA
Vacuum Contactors kA
Rated short time withstand (peak) current with
C/B and Disconnectors kA
Load break switches kA
Vacuum Contactors kA
Short circuit withstand time
s
Internal Arc Failure
Current kA
Duration s
Earthing Disconnector
Rated short circuit current making capacity kA
Rated short time withstand (peak) current kA
Rated short circuit withstand time s
50 - 60
630 ... 1250
630 ... 1250
630
400
250
630 ... 1250
630 ... 1250
630
400
200
630 ... 1250
630 ... 1250
630
-
16 - 20 - 25
16 - 20
8
16 - 20 - 25
16 - 20
8
16 - 20 - 25
16 - 20
8
40 - 50 - 63
40 - 50
20
1
40 - 50 - 63
40 - 50
20
1
40 - 50 - 63
40 - 50
20
1
16 - 20 - 25
1
16 - 20 - 25
1
16 - 20 - 25
1
16 - 20 - 25
40 - 50 - 63
1
16 - 20 - 25
40 - 50 - 63
1
16 - 20 - 25
40 - 50 - 63
1
Switchgear Structure as per the
loss of service continuity
internal arc classification
partition class
Protection Class
SME 7,2
LSC 2A
AFL
PI
when doors are closed
between compartments
IP 40
IP 20
RAL 9003 / 7035
IEC 62271-200
Color
Standards complied
Note: Full type tests of SME series switchgears up to 25 kA are performed at VEIKI accredited laboratories in Hungary.
17
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 6 Switchgears Types
Incoming with
Disconnector
Incoming Switchgear with Disconnector
Incoming with
Load Break Switch
Is the switchgear without protection and on load switching
features, with the rated current up to 1250 A and short circuit
level up to 25 kA.
Incoming Switchgear with Load Break Switch
Is the switchgear which allows the switching on load but
without protection features with the rated current up to
630 A and short circuit level up to 20 kA.
Cable Connection Switchgear
Cable connection
Is the switchgear to connect the distribution busbar with
the cables connected from the bottom without using any
switching and protection features with the rated current
up to 1250 A and short circuit level up to 25 kA.
Incoming/Outgoing
with Circuit Breaker
Incoming/Outgoing Switchgear with Circuit Breaker
Is the switchgear for the incoming of distribution busbar
with rated current up to 1250 A and short circuit current
up to 25 kA which allows the protection and switching
operation during short circuit.
Outgoing Switchgear with Vacuum Contactor
Outgoing with
Vacuum Contactor
Is the switchgears used where frequent switching operation
is required with rated voltage up to 24 kV and rated current
up to 400 A.
Outgoing with
Load Break
Switch and fuses
Outgoing Switchgear with Load Break Switch and Fuse
Is the switchgear which allows the switching on load and contains
short circuit fuses for protection features with the rated current
up to 630 A and short circuit level up to 20 kA.
Bus Coupling Switchgear
Switchgear to connect the different busbars whether feed
by the same or different supply with rated current up to
1250 A and short circuit current up to 25 kA. This switchgear
is a combination of Bus section and Bus riser switchgears.
Bus Coupling
Bus Coupling with
Load Break Switch
Bus Coupling Switchgear with Load Break Switch
Switchgear where the connection of two different busbars
are realized manually without protection and paralleling
features whether feed by the same or different supply with
rated current up to 630 A and short circuit current up to
20 kA.
18
a Friem & Aktif Group Company
SME series Metal Enclosed Switchgears
Bus Section with
LBS / Disconnector
Bus Section Switchgear with Load Break Switch
Bus Section with
Circuit Breaker
Switchgear where the connection of two different busbars
are realized manually without protection and paralleling
features whether feed by the same or different supply with
rated current up to 630 A and short circuit current up to
20 kA.
Bus Section Switchgear with Circuit Breaker
Bus Riser
Switchgear where the connection of two different busbars
are realized automatically with protection and paralleling
features whether feed by the same or different supply with
rated current up to 1250 A and short circuit current up to
25 kA.
Bus Voltage
Measuring
Bus Rising Switchgear
Switchgear Is used for the connection of Bus section
switchgear' busbars by rising up to other busbar system
with rated current up to 1250 A and short circuit current
up to 25 kA.
Bus Voltage Measuring Switchgear
Current
Measuring
Switchgear is used for obtaining voltage information for
the measurement and protection purposes in the metal
enclosed busbar with rated current up to 1250 A and short
circuit current up to 25 kA with the help of Secondary
protection relays and measurement devices like Voltmeter,
Power Analyzers, Electricity meters, etc ...
Voltage & Current
Measuring with LBS
Bus Current Measurement Switchgears
Switchgear with rated current up to 1250 A and short circuit
current up to 25 kA in where the current information of the
distribution busbars is obtained for the using of Secondary
protection relays and measurement devices such as
Ammeter, Analyzers and Electricity Meters.
Current & Voltage Measuring Switchgears
Switchgear with rated current up to 630 A and short circuit
current up to 20 kA in which the current and voltage
information of the distribution busbars is obtained to use
at Secondary protection relays and measurement devices
such as Ammeter, Voltmeter, Analyzers and Electricity
Meters.
Surge Arrestor
Switchgears
Surge Arrester Switchgear
It is used on the busbars rated current up to 1250 A and
short circuit current up to 25 kA, to protect the system and
apparatus against temporary over voltages caused by the
lightning surges and switching surges.
19
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 6.1 Incoming Switchgear with Disconnector
Is the switchgear without protection and on load switching
features, with the rated current up to 1250 A and short circuit
level up to 25 kA.
In this switchgear 3 poles and 3 positioned (open– close- earthed)
SF6 gas insulated disconnector is used as standard and alternatively
Rotary Disconnectors may be used.
Incoming switchgears with disconnectors are used on;
Incoming of MV distribution busbar which does not stand
protection and load switching.
Switchgear Equipment
SF6 Gas Insulated Disconnector
Air Insulated Rotary switch *
Thermostat and Heater Kit
Copper Busbar
Capacitive Voltage Indicator Set
Fault Location indicator
Surge Arrestor
Current Transformer
Ammeter
Test Terminal
Cable Connection Terminal
SCADA Connections
Interlock
Options
Standard
x
x
x
x
x
x
x
x
x
x
x
x
x
* This product is an option of SF6 gas insulated disconnector.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
40.5
20
a Friem & Aktif Group Company
Width (mm)
375
500
750
1000
Depth (mm)
900
900
1400
1500
Height (mm)
2000
2000
2250
2300
SME series Metal Enclosed Switchgears
B 6.2 Incoming Switchgear with Load Break Switch
Is the switchgear which allows the switching on load but without
protection features with the rated current up to 630 A and short
circuit level up to 20 kA.
In this switchgear 3 poles and 3 positioned (open-close-earthed)
SF6 gas insulated Load Break switch is used as standard.
Incoming switchgears with Load Break Switch are used at;
- Incoming of MV distribution busbars and
- In some applications also at outgoing feeders
where there is no need for protection.
Switchgear Equipment
SF6 Gas Insulated Load Break Switch
Motor operation mechanism
Thermostat and Heater Kit
Copper Busbar
Capacitive Voltage Indicator Set
Fault Location indicator
Surge Arrestor
Current Transformer
Ammeter
Test Terminal
Remote Operation set
Cable Connection Terminal
SCADA Connections
Interlock
Standard
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
Width (mm)
375
500
750
Depth (mm)
900
900
1400
Height (mm)
2000
2000
2250
21
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 6.3 Cable Connection Switchgear
Is the switchgear to connect the distribution busbar with the
cables connected from the bottom without using any switching
and protection features with the rated current up to 1250 A and
short circuit level up to 25 kA.
Busbar connection switchgears are used to supply;
- Side connected Incoming switchgears
- Outgoing switchgears and
- Opposite busbar incoming fed from the outgoing cubicle at
opposite arrangement of switchgears.
which consist of switching and protection.
Switchgear Equipment
Standard
Earthing Disconnector
Thermostat and Heater Kit
Copper Busbar
Capacitive Voltage Indicator Set
Cable Connection Terminal
SCADA Connections
Interlock
Options
x
x
x
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
22
a Friem & Aktif Group Company
Width (mm)
375
500
750
Depth (mm)
900
900
1400
Height (mm)
2000
2000
2250
SME series Metal Enclosed Switchgears
B 6.4 Incoming Switchgear with Circuit Breaker
Is the switchgear for the incoming of distribution busbar with
rated current up to 1250 A and short circuit current up to 25 kA
which allows the protection and switching operation during short
circuit.
Switching is operated by 3 poles SF6 gas insulated Circuit Breaker
and Disconnection operation is realized by the using of 3 positioned
(open-close-earthed) SF6 gas insulated disconnector as standard
or Rotary switch as an option.
Incoming Switchgears with Circuit Breaker are used in;
- Network or Generator incoming feeders,
- Incoming feeders of Open/Close Ring operated networks.
Standard incoming switchgears are used also as outgoing
switchgear for any kind of application.
Switchgear Equipment
Circuit Breaker
SF6 Gas Insulated Disconnector
Air Insulated Rotary Switch *
Main Busbar Earthing Disconnector
Copper Busbar
Capacitive Voltage Indicator Set
Thermostat and Heater Kit
Surge Arrestor
Voltage Transformer
Voltmeter and Commutator set
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Over Current Relay
Other secondary protection relays
Cable Connection Terminal
SCADA Connections
GSM-GPRS Modem Converter Set
Interlock
*
Standard
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
This product is an option of SF6 gas insulated disconnector.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
40.5
Width (mm)
750
750
1000
1200
Depth (mm)
900
900
1400
1500
Height (mm)
2000
2000
2250
2300
23
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 6.5 Outgoing Switchgear with Circuit Breaker
Is the switchgear for the outgoing from distribution busbar
with rated current up to 1250 A and short circuit current up
to 25 kA which allows for the protection and switching
operation during short circuit.
Switching is operated with 3 poles SF6 gas insulated Circuit
Breaker and Disconnection operation is realized by the using
of 3 positioned (open-close-earthed) SF6 gas insulated
disconnector as standard or Rotary switch as an option.
Outgoing Switchgears with Circuit Breaker are mainly used in;
- Any load feeders supplied from Distribution Busbars
- Line feeders supplied from Distribution Busbars
- Outgoing feeders of Open/Close Ring operated networks.
Standard outgoing switchgears are used as Incoming
switchgears at some site application.
Switchgear Equipment
Circuit Breaker
SF6 Gas Insulated Disconnector
Air Insulated Rotary Switch*
Main Busbar Earthing Disconnector
Copper Busbar
Capacitive Voltage Indicator Set
Thermostat and Heater Kit
Surge Arrestor
Voltage Transformer
Voltmeter and Commutator set
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Over Current Relay
Other secondary protection relays
Cable Connection Terminal
SCADA Connections
GSM-GPRS Modem Converter Set
Interlock
*
Standard
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
This product is an option of SF6 gas insulated disconnector.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
40.5
24
a Friem & Aktif Group Company
Width (mm)
750
750
1000
1200
Depth (mm)
900
900
1400
1500
Height (mm)
2000
2000
2250
2300
SME series Metal Enclosed Switchgears
B 6.6 Outgoing Switchgear with Vacuum Contactor
Is the switchgears used where frequent switching operation
is required with rated voltage up to 24 kV and rated current
up to 400 A.
For the switching operation 3 poles vacuum contactor is used
and disconnection operation is realized by 3 poles 3 positioned
(open-close-earthed) SF6 gas insulated disconnector as
standard or air insulated Rotary Switch as an alternative.
Outgoing Switchgear with contactor is used for feeding of;
- Capacitor Banks
- Harmonic Filters
- Shunt Reactors and
- Motors
Switchgear Equipment
Vacuum Contactor
SF6 Gas Insulated Disconnector
Air insulated Rotary Switch *
Copper Busbar
Capacitive Voltage Indicator Set
M.V. Protection Fuses
Thermostat and Heater Kit
Surge arrester
Current Transformer
Ammeter
Over Current Relay
Other secondary protection relays
Test Terminal
Cable Connection Terminal
SCADA Connections
GSM-GPRS Modem Converter Set
Interlock
*
Standard
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
This product is an option of SF6 gas insulated disconnector.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
Width (mm)
750
750
Depth (mm)
900
900
Height (mm)
2000
2000
25
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 6.7 Outgoing Switchgear with Load Break Switch
and Fuse
Is the switchgear which allows the switching on load and contains
short circuit fuses for protection features with the rated current up
to 630 A and short circuit level up to 20 kA.
In this switchgear 3 poles and 3 positioned (open-close-earthed) SF6
gas insulated Load Break switch is used as standard.
Outgoing switchgear with fused type Load Switch is used for;
- Feeding of Transformers with rated power up to 400 kVA
- Feeding of Transformers with rated power up to 1600 kVA
with the condition of being in the same location with distribution
transformer.
Switchgear Equipment
SF6 Gas Insulated Load Break Switch
Motor operating mechanism
Copper Busbar
Capacitive Voltage Indicator Set
M.V. Protection Fuses
Thermostat and Heater Kit
Remote Operation set
Cable Connection Terminal
SCADA Connections
Interlock
Standard
x
Options
x
x
x
x
x
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
26
a Friem & Aktif Group Company
Width (mm)
375
500
750
Depth (mm)
900
900
1400
Height (mm)
2000
2000
2250
SME series Metal Enclosed Switchgears
B 6.8 Bus Coupling Switchgear
Switchgear to connect the different busbars whether feed by
the same or different supply with rated current up to 1250 A
and short circuit current up to 25 kA. This switchgear is a
combination of Bus section and Bus riser switchgears.
Inside the switchgear 3 poles SF6 gas insulated Circuit
Breaker and 2 pieces of 3 positioned (open-close-earthed)
SF6 gas insulated Disconnectors are used as standard.
Bus Coupling Switchgears are used to;
- Connect two different busbars and
- Synchronizing of Power plants or Renewable Energy
supplies to the network.
x
Switchgear Equipment
Circuit Breaker
SF6 Gas Insulated Disconnectors
Air Insulated Rotary Switches *
Thermostat and Heater Kit
Copper Busbar
Voltage Transformer
Voltmeter and Commutator set
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Over Current Relay
Other secondary protection relays
Cable Connection Terminal
SCADA Connections
GSM-GPRS Modem Converter Set
Interlock
*
Options
Standard
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
This product is an option of SF6 gas insulated disconnector.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
40.5
Width (mm)
1125 *
1250 *
1750 *
2200
Depth (mm)
900
900
1400
1500
Height (mm)
2000
2000
2250
2300
* This product is an option of SF6 gas insulated disconnector.
27
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 6.9 Bus Coupling Switchgear with Load Break
Switch
Switchgear where the connection of two different busbars are realized
manually without protection and paralleling features whether feed
by the same or different supply with rated current up to 630 A and
short circuit current up to 20 kA.
In this switchgear SF6 gas insulated Load Break switch with 3 poles
and 3 positions (open-close-earthed) is used as standard. Instead of
LBS, SF6 gas insulated disconnector or Rotary switch can be used
optionally also to increase the rated current to 1250A, and short
circuit current to 25 kA.
Bus Coupling Switchgear with Load Break switch is used to connect
two busbars each other manually or automatically without
protection.
Switchgear Equipment
Standard
SF6 Gas Insulated Load Break Switch
SF6 Gas Insulated Disconnector *
Air Insulated Rotary Switch *
Motor set for spring charging
Thermostat and Heater Kit
Copper Busbar
Capacitive Voltage Indicator Set
Voltage Transformer
Voltmeter and Commutator set
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Motor set for Remote Open-Close
SCADA Connections
Interlock
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
* These products are the option of SF6 gas insulated Load Break switch when there is
no need to switching on-load.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
28
a Friem & Aktif Group Company
Width (mm)
750
1000
1150
Depth (mm)
900
900
1400
Height (mm)
2000
2000
2250
SME series Metal Enclosed Switchgears
B 6.10 Bus Section Switchgear with Load Break
Switch
Switchgear where the connection of two different busbars are realized
manually without protection and paralleling features whether feed
by the same or different supply with rated current up to 630 A and
short circuit current up to 20 kA.
In this switchgear SF6 gas insulated Load Break switch with 3 poles
and 3 positions (open-close-earthed) is used as standard. Instead of
LBS, SF6 gas insulated disconnector or Rotary switch can be used
optionally also to increase the rated current to 1250A, and short
circuit current to 25 kA.
Bus Section Switchgear with Load Break switch is used to connect
two busbars each other manually or automatically without
protection especially at opposite arrangement of busbars.
Switchgear Equipment
Standard
SF6 Gas Insulated Load Break Switch
SF6 Gas Insulated Disconnector *
Air Insulated rotary Disconnector *
Motor set for spring charging
Thermostat and Heater Kit
Copper Busbar
Capacitive Voltage Indicator Set
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Motor set for remote open-close
SCADA Connections
GSM/GPRS Modem Converter Set
Interlock
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
* These products are the option of SF6 gas insulated Load Break switch when there is no
need to switching on-load.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
Width (mm)
375
500
750
Depth (mm)
900
900
1400
Height (mm)
2000
2000
2250
29
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 6.11 Bus Section Switchgear with Circuit Breaker
Switchgear where the connection of two different busbars are
realized automatically with protection and paralleling features
whether feed by the same or different supply with rated current
up to 1250 A and short circuit current up to 25 kA.
3 poles SF6 gas insulated Circuit Breaker with 3 poles and 3
positions (open-close-earthed) Disconnector is used as
standard in this switchgear. Also air insulated Rotary Switch
can be used as a disconnection option.
Busbar Coupling Switchgear with Circuit Breaker is used;
- Connect two different busbars and
- Synchronizing of Power plants or Renewable Energy supplies
to the network especially at opposite arrangement of
busbars.
Hücre Donanımları
Circuit breaker
SF6 Gas insulated Disconnector
Air type Rotary switch *
Thermostat and heater kit
Copper busbar
Capacitif voltage indicator
Current transformer
Ammeter
Power Analyzer
Electricty meter
Over current relay
Other secondary protection relays
SCADA connection
GSM-GPRS Modem/Converter Set
Interlock
*
Opsiyonel
Standart
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
This product is an option of SF6 gas insulated disconnector.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
40,5
30
a Friem & Aktif Group Company
Width (mm)
750
750
1000
1200
Depth (mm)
900
900
1400
1500
Height (mm)
2000
2000
2250
2300
SME series Metal Enclosed Switchgears
B 6.12 Bus Rising Switchgear
Switchgear Is used for the connection of Bus section
switchgear' busbars by rising up to other busbar system
with rated current up to 1250 A and short circuit current up
to 25 kA.
Bus riser switchgears may contain 3 poles 3 positioned
(open-close-earthed) disconnector or rotary switch in case
of switching necessity.
Bus Riser switchgear is used with Bus Section to connect
two busbars.
Switchgear Equipment
SF6 gas insulated disconnector
Air insulated Rotary switch
Thermostat and Heater Kit
Copper Busbar
Voltage Transformer
Voltmeter and Commutator set
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Options
x
x
Standard
x
x
x
x
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
40,5
Width (mm)
375
500
750
1000
Depth (mm)
900
900
1400
1500
Height (mm)
2000
2000
2250
2300
31
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 6.13 Bus Voltage Measuring Switchgear
Switchgear is used for obtaining voltage information for the
measurement and protection purposes in the metal
enclosed busbar with rated current up to 1250 A and short
circuit current up to 25 kA with the help of Secondary
protection relays and measurement devices like Voltmeter,
Power Analyzers, Electricity meters, etc ...
In this switchgear SF6 gas insulated Disconnector with 3 poles
and 3 positions (open-close-earthing) is used as standard and
also Air insulated rotary switch can be used as an option.
Bus Voltage Measuring Switchgears are used for the receiving of;
- Measurement and protection basis Voltage data.
- Billing basis Energy consumption measurement.
- Providing auxiliary power up to 2.5 kVA in Low Voltage.
Switchgear Equipment
SF6 Gas Insulated Disconnector
Air-Insulated rotary Switch *
Thermostat and Heater Kit
Copper Busbar
Medium Voltage Fuse
Voltage Transformer
Voltmeter and commutator set
Power Analyzer
Electricity Meter
SCADA Connections
*
Options
Standard
x
x
x
x
x
x
x
x
x
x
This product is an option of SF6 gas insulated disconnector.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
40,5
Width (mm)
375 *
500 *
750 *
1000
Depth (mm)
900
900
1400
1500
Height (mm)
2000
2000
2250
2300
* When rotary switcher is used 750 mm for 12 kV and 24 kV, 1000 mm for 36 kV.
32
a Friem & Aktif Group Company
SME series Metal Enclosed Switchgears
B 6.14 Bus Current Measurement Switchgears
Switchgear with rated current up to 1250 A and short circuit
current up to 25 kA in where the current information of the
distribution busbars is obtained for the using of Secondary
protection relays and measurement devices such as
Ammeter, Analyzers and Electricity Meters.
Bus Current Measuring Switchgear is used for the receiving of :
- Measurement and Protection basis Current data,
- Billing basis Energy consumption measurement.
Switchgear Equipment
Thermostat and Heater Kit
Copper Busbar
Current Transformer
Ammeter
Electricity meter
Standard
x
x
x
Optional
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
40,5
Width (mm)
750
750
1000
1200
Depth (mm)
900
900
1400
1500
Height (mm)
2000
2000
2250
2300
33
a Friem & Aktif Group Company
B
B
SME series Metal Enclosed Switchgears
B 6.15 Current & Voltage Measuring Switchgears
Switchgear with rated current up to 630 A and short circuit
current up to 20 kA in which the current and voltage information
of the distribution busbars is obtained to use at Secondary
protection relays and measurement devices such as Ammeter,
Voltmeter, Analyzers and Electricity Meters.
In this switchgear SF6 gas insulated Load Break switch with
3 poles and 3 positions (open-close-earthed) is used as
standard. Instead of LBS, SF6 gas insulated disconnector or
Rotary switch can be used optionally also to increase the rated
current to 1250A, and short circuit current to 25 kA.
Current & Voltage Measuring Switchgear is used for the receiving of;
- Main Measurement basis Current and Voltage data,
- Billing basis Energy consumption measurement.
Switchgear Equipment
Standard
SF6 Gas Insulated Load Break Switch
SF6 Gas Insulated Disconnector *
Air Insulated rotary Switch *
Motor set for spring charging
Thermostat and Heater Kit
Copper Busbar
Medium Voltage Fuse
Voltage Transformer
Voltmeter and Commutator set
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Motor set for Remote open-close
SCADA Connections
GSM/GPRS Modem Converter Set
Interlock
Optional
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
* If more current capacity is needed it's possible to use SF6 Disconnector or Rotary Switch
instead of LBS.
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
34
a Friem & Aktif Group Company
Width (mm)
750
1000
1150
Depth (mm)
900
900
1400
Height (mm)
2000
2000
2250
SME series Metal Enclosed Switchgears
B 6.16 Surge Arrester Switchgear
It is used on the busbars rated current up to 1250 A and short
circuit current up to 25 kA, to protect the system and apparatus
against temporary over voltages caused by the lightning surges
and switching surges.
Switchgear Equipment
Thermostat and Heater Kit
Copper Busbar
Surge Arrestor
Standard
x
x
x
Options
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
17.5 - 24
36
40,5
Width (mm)
375
500
750
1000
Depth (mm)
900
900
1400
1500
Height (mm)
2000
2000
2250
2300
35
a Friem & Aktif Group Company
B
C 1 Metal Clad Switchgears with Single Busbar
C 1.1 Compartments
C 1.2 Application Areas
C 1.3 Advantages
C 1.4 Standards Complied
C 1.5 Technical Specifications
C 1.6 Switchgears Types
C 1.6.1 Incoming/Outgoing Switchgears
C 1.6.2 Outgoing Switchgears with Vacuum Contactor
C 1.6.3 Cable Connection Switchgear
C 1.6.4 Bus Section Switchgears
C 1.6.5 Bus Riser Switchgear
C 1.6.6 Bus Voltage Measuring Switchgears
C 1.6.7 Current & Voltage Measuring Switchgears
C 2 Metal Clad Switchgears with Double Busbar
C 2.1 Compartments
C 2.2 Application Areas
C 2.3 Advantages
C 2.4 Standards Complied
C 2.5 Technical Specifications
C 2.6 Switchgears Types
C 2.6.1 Double Bus Incoming / Outgoing Switchgears
C 2.6.2 Double Bus Coupling Switchgears
C 2.6.3 Double Bus Voltage Measuring Switchgears
C 2.6.4 Double Bus Current & Voltage Measuring Switchgears
38
40
41
43
43
43
44
45
46
47
48
49
50
51
52
54
54
55
55
56
56
57
58
59
60
61
Metal Clad
Switchgear
C
SMC series Metal Clad Switchgears
C 1 Metal Clad Switchgearswith single Busbar
Metal Clad Switchgears are switching and control cabinets
manufactured between 1 kV … 40.5 kV in conformity with IEC
62271-200 standards.
The Metal Clad Switchgears are manufactured from steel
structures in vertical position as free-standing which contain
withdrawable/cassette type Circuit breakers, Main, distribution
and grounding busbars, Current-Voltage Transformers,
Protection and Control equipment.
Main structures consist of 3 mm sheet steels and painted with
electrostatic powder paint in conformance with RAL codes.
Metal Clad Switchgears manufactured by Aktif Elektroteknik
since 1989 as passed the tests successfully in the accredited
international laboratories in Europe (CESI/Italy).
SMC series Metal Clad Switchgears are defined with following
features according to IEC 62271-200.
Air insulated
LSC 2B Loss of Service continuity
PM Partition class
AFLR Internal Arc Classification
4 accessible compartments
40
a Friem & Aktif Group Company
SMC series Metal Clad Switchgears
C 1.1 Compartments
b
Metal clad Switchgears consist of 4 compartments segregated
from each other by grounded metal compartments:
a - Switching Compartment
b - Low Voltage Compartment
c - Busbar Compartment
d - Cable Compartment
c
a - Switching Compartment
The switching compartment consists of following units:
a
Switching Equipments (circuit breaker-contactor, etc.)
Withdrawable truck
Switchgear door contains operating mechanism of truck and
earthing switch
Individual and lockable grounded automatic shutters
d
Switching Compartment may have the following switching
equipment according to the project.
Vacuum circuit breaker
SF6 circuit breaker
Contactor
Fuses
Switching compartment access is controlled by integral design
of Metal Clad Switchgear to ensure safe operation according to
IEC 62271-200
The following mechanic Interlocks are provided as standard:
The withdrawal or engagement of the C/B is not possible during
the C/B is “On” position
The operation of the C/B is not possible unless it is in service
and test position
It is not possible to open the switching compartment door when
it is in service position
It is not possible to close the C/B when switching compartment
door is open
Closing of earthing switch is not possible if circuit breaker
truck is in service position
The operation of the C/B is not possible when earthing switch
is closed
41
a Friem & Aktif Group Company
C
C
SMC series Metal Clad Switchgears
b - Low Voltage Compartment
This compartment contains all secondary circuits for control,
measurement, protection, monitoring, communication and
other associated systems
c - Busbar Compartment
Busbar Compartment mainly consists of;
- Electrolytic copper busbars according to rated current.
- Epoxy resin post insulators
Access to busbar compartment is possible with special safety
procedures and tools.
d - Cable Compartment
Followings equipment is located inside Cable compartments;
Current transformer
Voltage transformer
Surge arrestor
Earthing switch
Capacitive voltage divider
Cable gland and connection fixtures
Special procedures are required. Tools are necessary for
opening for access.
Access to cable compartment is possible with special safety
procedures and tools.
42
a Friem & Aktif Group Company
SMC series Metal Clad Switchgears
C 1.2 Application Areas
Energy Transmission and Distribution Centers
Hydroelectric Power Plants
Diesel and Natural Gas Power Plants
Transformer Substations
Cement Factories
Auto Industry
Petroleum and Chemical Industry
Iron and Steel Industry
Rolling Mills
Pipelines
Electro Chemical Facilities
Shipyards
Emergency Situation and Stand-by Power Plants
Ore Mines
Railway Substations
C 1.3 Advantages
LSC2B Maximum Service Continuity
Earthed metal partitions between compartments
Maximum human safety with AFLR internal arc
testing feature
Safety electrical and mechanical Interlocks doesn't allow to
operational faults
Withdrawable type Vacuum / SF6 Circuit breaker for fast and
easy servicing
Earthing system, continuity ensured
Modular compact design, allows any future expansion
Tested short time withstand currentat 31.5 kA / 3 s.
Long operational life - 10.000 switching
Interactive mimic diagram
Proven reliability with unique design
Low maintenance cost
Easy and safety operation
After sale service and spare parts availability
C 1.4 Standards Complied
SMC series Metal Clad Switchgears are manufactured in
conforming to following standards:
IEC 62271-1
IEC 62271-200
IEC 62271-100
IEC 62271-102
IEC 62271-105
IEC 60044-1
IEC 60044-2
IEC 60273
IEC 60051
IEC 60255
: General articles relating to High Voltage
Switchgears
: Metal Enclosed Switchgears (1 - 52 kVac]
: Circuit Breakers (1 - 52 kVac]
: Main Circuit and grounding Disconnectors
: AC Switch and Fuse Combinations
: Current Transformers
: Voltage Transformers
: Insulators
: Measuring Devices
: Secondary Protection relays
43
a Friem & Aktif Group Company
C
C
SMC series Metal Clad Switchgears
C 1.5 Technical Specifications
Technical Specifications
Descriptions
Rated Voltage (rms)
Power frequency withstand Voltage 50 Hz, 1
min (rms) between phases and phase-ground
Lightning impulse withstand Voltage 1.2/50 ms
(peak) between phases and phase - ground
Rated frequency
Rated (rms) current of switchgears with
Busbars (with natural ventilation)
(forced ventilation)
C/B and Disconnector (with natural ventilation)
(forced ventilation)
Load break switches
Vacuum Contactors (inductive switching)
Vacuum Contactors (capacitive switching)
Rated short time withstand (rms) current with
C/B and Disconnectors
Load break switches
Vacuum Contactors
Rated short time withstand (peak) current with
C/B and Disconnectors
Load break switches
Vacuum Contactors
Short circuit withstand time
up to 31.5 kV
above 31.5 kV
Internal Arc withstand
SMC 3,6
SMC 7,2
SMC 12
SMC 17,5
SMC 24
SMC 36
SMC 40,5
kV
3,6
7,2
12
17,5
24
36
40,5
kV
10
20
28
38
50
70
85
kV
40
60
75
95
125
170
185
50 - 60
Hz
A
A
A
A
A
A
A
630 ... 3150
5000
630 ... 3150
5000
630
400
250
630 ... 3150
5000
630 ... 3150
5000
630
800
200
630 ... 3150
5000
630 ... 3150
5000
630
-
16 ... 50
16 - 20
8
16 ... 50
16 - 20
8
16 ... 50
16 - 20
-
40 ... 125
40 - 50
20
40 ... 125
40 - 50
20
40 ... 125
40 - 50
-
3
1
3
1
3
1
16 ... 31.5
1
16 ... 31.5
1
16 ... 31.5
1
16 ... 50
3
1
16 ... 50
3
1
16 ... 50
3
1
kA
kA
kA
kA
kA
kA
s
s
Current kA
Duration s
Earthing Disconnector
Rated short time withstand current kA
Duration (up to 31.5 kA) s
(above 31.5 kA) s
Switchgear Structure as per the
loss of service continuity
internal arc classification
partition class
LSC 2B
AFLR
PM
Protection Class
when doors are closed - standard
optional
between compartments
Color
IP 40
IP 42
IP 20
RAL 9003 / 7035
IEC 62271-200
Standards complied
Note: Full type tests of SMC switchgears up to 31.5 kA are performed at CESI accredited laboratories in Italy.
44
a Friem & Aktif Group Company
SMC series Metal Clad Switchgears
C 1.6 Switchgears Types
Incoming/Outgoing
Outgoing with
Vacuum Contactor
Incoming/Outgoing Switchgear
is the switchgear for incoming and outgoing from the
distribution busbar with rated current up to 3150 A and
short circuit current up to 50 kA which allows to switch
operation during short circuit.
Outgoing Switchgears with Vacuum Contactor
is the switchgears used where frequent switching operation
is required with rated voltage up to 24 kV and rated current
up to 400 A.
Cable Connection
Cable Connection Switchgear
Bus Section
is the switchgear with rated current up to 3150 A and short
circuit current up to 50 kA and the incoming distribution
connection realized by busbar
Bus Section Switchgear
is the switchgear with rated current up to 3150 A and short
circuit current up to 50 kA where the dividing of the main
busbar is needed and allows to switching operation during
short circuit.
Bus Riser Switchgear
Bus Riser
is the switchgear used for the purpose of rising the busbar
connections to the other busbar level which is divided by
the Bus section switchgear, with rated current up to
3150 A and short circuit current up to 50 kA.
Bus Voltage
Measuring
Bus Voltage Measuring Switchgear
is the switchgear used for obtaining voltage information for
the measurement and protection purposes in the metal
clad busbar with rated current up to 3150 A and short circuit
current up to 50 kA with the help of Secondary protection
relays and measurement devices like Voltmeter, Power
Analyzers, Electricity meters...
Current & Voltage Measuring Switchgear
Current & Voltage
Measuring
is the switchgear used for obtaining current information for
the measurement and protection purposes in the metal clad
busbar with rated current up to 3150 A and short circuit current
up to 50 kA with the help Secondary protection relays and
measurement devices like Ammeter, Power Analyzers,
Electricity meters...
45
a Friem & Aktif Group Company
C
C
SMC series Metal Clad Switchgears
C 1 6.1 Incoming/Outgoing Switchgear
is the switchgear for incoming and outgoing of distribution
busbar with rated current up to 3150 A and short circuit
current up to 50 kA which allows the protection and the
switching operation during short circuit.
Switching is operated by 3 poles Vacuum or SF6 gas insulated
Circuit Breaker. Disconnection operation is realized by the
turning of the unit in to the test position after the circuit
breaker on withdrawable truck is switched to off position.
Incoming/Outgoing Switchgears with Circuit Breaker are used in;
- Network or Generator incoming feeders
- All Load feeders supplied from Distribution Busbars
- Incoming or Outgoing feeders of Open/Close Ring operated
networks.
X
TRIP
Imax
Uab
VA
OPEN
RCL
LRC
0 A0 V
POWER
CLOSED
0.00 k
Disable
Not Avail
<Menu>
<<<
<<<
I
O
RS232
Switchgear Equipments
Circuit Breaker
Earthing Disconnector
Main Busbar Earthing Disconnector
Copper Busbar
Capacitive Voltage Indicator Set
Thermostat and Heater Kit
Surge Arrestor
Medium Voltage Fuse
Voltage Transformer
Current Transformer
Voltmeter and Commutator set
Ammeter
Power Analyzer
Electricity Meter
Over Current Relay
Other secondary protection relays
Cable Connection Terminal
Fault indicator relay
SCADA Connectionss
GSM-GPRS Modem Converter Set
Interlock
Standard
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Switchgear Dimensions (Vacuum C/B)
Rated Voltage (kV)
3.6 - 24
36 - 40.5
Width (mm)
800
1200
Depth (mm
2000
3000
Height (mm)
2100
2300
Switchgear Dimensions (SF6 C/B)
Rated Voltage (kV)
3.6 - 24
36 - 40.5
46
a Friem & Aktif Group Company
Width (mm)
1100
1400
Depth (mm
2350
3000
Height (mm)
2100
2300
SMC series Metal Clad Switchgears
C 1 6.2 Outgoing Switchgears with Vacuum Contactor
the switchgears used where frequent switching operation is
required with rated voltage up to 24 kV and rated current up
to 400 A.
For the switching operation 3 poles vacuum contactor is
used. Disconnection operation is realized by the turning of
the unit in to the test position after the contactor on
withdrawable truck switched to off position.
Outgoing Switchgear with contactor is used for feeding of;
- Capacitor Banks
- Harmonic Filters
- Shunt Reactors and
- Motors
Switchgear Equipments
Standard
Vacuum Contactor
Earthing disconnector
Thermostat and Heater Kit
Copper Busbar
Capacitive Voltage Indicator Set
Medium Voltage Fuses
Current Transformers
Over Current Relay
Other secondary protection relays
Test terminal
Fault indicator device
SCADA Connections
GSM-GPRS Modem Converter Set
Interlock
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 12
Width (mm)
800
Depth (mm)
2000
Height (mm)
2100
47
a Friem & Aktif Group Company
C
C
SMC series Metal Clad Switchgears
C 1 6.3 Cable Connection Switchgear
Switchgear allows to connect main busbar system from
another busbar system up to 3150 A rated current and 50 kA
short circuit current.
This switchgear doesn't contain any protection and breaking
possibility. The disconnection is possible only by the turning
the unit in to the test position to remove the connection
busbar from the main distribution busbar after the circuit
breaker on supply feeder is switched to off position.
Incoming Switchgears with busbar are used in;
- Opposite busbar incoming, fed from the outgoing cubicle
at opposite arrangement of switchgears.
Switchgear Equipments
Earthing Disconnector
Thermostat and Heater Kit
Copper Busbar
Capacitive Voltage Indicator Set
Surge Arrestor *
MV Fuses
Voltage Transformer
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Test Terminal
Cable Connection Terminal
SCADA Connections
Interlock
Standard
x
x
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 24
36 - 40.5
48
a Friem & Aktif Group Company
Width (mm)
800
1200
Depth (mm)
2000
3000
Height (mm)
2100
2300
SMC series Metal Clad Switchgears
C 1 6.4 Bus Section Switchgear
the switchgear with rated current up to 3150 A and short
circuit current up to 50 kA where the dividing of the main
busbar is needed and allows for switching operation during
short circuit.
For the switching operation 3 poles Vacuum or SF6 gas
insulated Circuit Breaker is used on withdrawable truck.
Disconnection operation is realized by the turning of the unit
in to the test position after the circuit breaker on
withdrawable truck is switched to off position.
Bus Section Switchgear is used to connect/disconnect two
Busbars automatically or with remote switching operation
with Secondary Protection.
Switchgear Equipments
X
TRIP
VA
Imax
Uab
RCL
LRC
0 A0 V
POWER
CLOSED
OPEN
0.00 k
Disable
Not Avail
<Menu>
Standard
<<<
<<<
Circuit Breaker
Thermostat and Heater Kit
Copper Busbar
Capacitive Voltage Indicator Set
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Over Current Relay
Other secondary protection relay
Test Terminal
SCADA Connections
GSM-GPRS Modem Converter Set
Interlock
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
I
O
RS232
Switchgear Dimensions (Vacuum C/B)
Rated Voltage (kV)
3.6 - 24
36 - 40.5
Width (mm)
800
1200
Depth (mm)
2000
3000
Height (mm)
2100
2300
Hücre Ölçüleri (SF6 Gazl› Kesicili)
Rated Voltage (kV)
3.6 - 24
36 - 40.5
Width (mm)
1100
1400
Depth (mm)
2350
3000
Height (mm)
2100
2300
49
a Friem & Aktif Group Company
C
C
SMC series Metal Clad Switchgears
C 1 6.5 Bus Riser Switchgear
is the switchgear used for the purpose of rising the busbar
connections to the other busbar level which is divided by the Bus
section switchgear, with rated current up to 3150 A and short circuit
current up to 50 kA.
Voltage transformers can be used optionally in this switchgear to
obtain voltage information.
Bus Riser Switchgear is used with Bus Section Switchgear.
Switchgear Equipment
Standard
Thermostat and Heater Kit
Copper Busbar
Voltage Transformer
Voltmeter and Commutator set
Options
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 24
36 - 40.5
50
a Friem & Aktif Group Company
Width (mm)
500
800
Depth (mm)
2000
3000
Height (mm)
2100
2300
SMC series Metal Clad Switchgears
C 1.6.6 Bus Voltage Measuring Switchgears
Switchgear is used for obtaining voltage information for the
measurement and protection purposes in the metal clad
busbar with rated current up to 3150 A and short circuit
current up to 50 kA with the help of Secondary protection
relays and measurement devices like Voltmeter, Power
Analyzers, Electricity meters, etc ...
Disconnection is realized by the turning of the unit in to the
test position.
Bus Voltage Measuring Switchgears are used in :
- Measurement and protection basis Voltage data reading.
- Billing basis Energy consumption measurement reading.
- Providing auxiliary power up to 2.5 kVA in Low Voltage.
Switchgear Equipment
Standard
Thermostat and Heater Kit
Copper Busbar
Medium Voltage Fuses
Voltage Transformer
Voltmeter and Commutator Set
Power Analyzer
SCADA Connections
Interlock
Options
x
x
x
x
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 24
36 - 40.5
Width (mm)
800
1200
Depth (mm)
2000
3000
Height (mm)
2100
2300
51
a Friem & Aktif Group Company
C
C
SMC series Metal Clad Switchgears
C 1.6.7 Current & Voltage Measuring Switchgears
Switchgear with rated current up to 3150 A and short circuit
current up to 50 kA in which the current and voltage
information of the distribution busbars are obtained by using
Secondary protection relays and measurement devices such
as Ammeter, Voltmeter, Analyzers and Electricity Meters.
Disconnecting operation is not requested in such kind of
feeders to be able to measure the energy consumption
continuously.
Metering Switchgears are used for the receiving of;
- Main Measurement basis Current and Voltage data.
- Billing basis Energy consumption measurement.
Switchgear Equipment
Standard
Thermostat and Heater Kit
Copper Busbar
Medium Voltage Fuses
Voltage Transformer
Current Transformer
Electricity Meter
Voltmeter and Commutator Set
Ammeter
Power Analyzer
SCADA Connections
Interlock
Options
x
x
x
x
x
x
x
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
3.6 - 24
36 - 40.5
52
a Friem & Aktif Group Company
Width (mm)
800
1200
Depth (mm)
2000
3000
Height (mm)
2100
2300
SMC series Metal Clad Switchgears
53
a Friem & Aktif Group Company
C
C
SMC series Metal Clad Switchgears
C 2 Metal Clad Switchgears with Double
Busbar
b
c
Switchgears with double busbar are used for balancing the
load for the medium voltage distribution systems that feed
from two different sources by taking the capacity into the
consideration. Furthermore, it is also used for utilizing the
busbar of one source when the other source cannot get energy
to its busbar due to a power cut-off. It makes advantage to
distribution system for the continuity of energy supply.
C 2.1 Compartments
Metal clad Switchgears with double busbar system contain
the following compartments which are segregated from
each other with grounded metal compartment.
c d
a
a- Switching Equipment Compartment
b- Low Voltage Command Compartment
c- Busbar Compartments
d- Cable Compartment
a- Switching Equipment Compartment
Switching Compartment consists of the following units:
Switching Equipment (Circuit breaker-contactor, etc.)
Elevator type of withdrawable truck
Switchgear door contains operating mechanism of truck and
earthing switch
Individual and lockable grounded metal separator
b
Switching compartment may have the following Switching
Equipment as per the necessity of the project
Vacuum Circuit breaker
SF6 Circuit breaker
Contactor
Fuses
In order to provide operational safety, the metal clad Switchgears
are manufactured in line with the criteria defined in IEC 62271-200
Access to Switching compartment is controlled by integral
design of Metal Clad Switchgear to ensure safe operation
according to IEC 62271-200
The following mechanic Interlocks are provided as standard:
The withdrawal or engagement of the C/B is not possible
during the C/B is “On” position
The operation of the C/B is not possible unless it is in service
and test position
It is not possible to open the switchgear door when it is in
service position
It is not possible to close the C/B when switching
compartment door is open.
Closing of earthing switch is not possible if circuit breaker
truck is in service position
The operation of the CB is not possible when earthing switch
is closed.
a
54
a Friem & Aktif Group Company
SMC series Metal Clad Switchgears
b- Low Voltage Compartment
This compartment contains all secondary circuits for
control, measurement, protection, monitoring,
communication and other associated systems.
c- Busbar Compartment
Busbar Compartment mainly consists of;
Electrolytic copper busbars according to rated current.
Epoxy resin post insulators
Access to busbar compartment is possible with special safety
procedures and tools.
d- Cable Compartment
Followings equipments are located inside Cable compartments;
Current transformer
Voltage transformer
Surge arrestor
Earthing switch
Capacitive voltage divider
Cable gland and connection fixtures
Access to Cable compartment is possible with special safety
procedures and tools.
C 2.2 Application Areas
The industrial or distribution companies that get their energy
from two different sources utilize double busbar systems in
order to be able to perform load balancing at the main busbar.
In this application, bus A or bus B distributes uninterrupted
power and also balances the loads on two busbars.
Energy Distribution Centers
Industrial Zones
Metallurgy and Cement Factories
Petrochemical Plants
C 2.3 Advantages
Minimum influences from the faults occurring energy feeding
points.
More power distribution from a single energy center
Balancing energy consumption rates between two busbars in
systems that are fed by two sources and providing uninterrupted
power distribution.
55
a Friem & Aktif Group Company
C
C
SMC series Metal Clad Switchgears
C 2.4 Standards Complied
SMC series Metal Clad Switchgears are manufactured in
conformance with the following standards:
IEC 62271-1
IEC 62271-200
IEC 62271-100
IEC 62271-102
IEC 62271-105
IEC 60044-1
IEC 60044-2
IEC 60273
IEC 60051
IEC 60255
: General articles relating to High Voltage
Switchgears
: Metal Enclosed Switchgears (1 - 52 kVac)
: Circuit Breakers (1 - 52 kVac)
: Main Circuit and Earthing Disconnector
: AC Switches and Fuse Combinations
: Current Transformers
: Voltage Transformers
: Insulators
: Measuring Devices
: Secondary Protection relays
C 2.5 Technical Specifications
Technical Specifications
Descriptions
Rated Voltage (rms)
Power frequency withstand Voltage 50 Hz, 1
min (rms) between phases and phase-ground
Lightning impulse withstand Voltage 1.2/50 ms
(peak) between phases and phase - ground
Rated frequency
Rated (rms) current of switchgears with
Busbars (with natural ventilation)
(forced ventilation)
C/B and Disconnector (with natural ventilation)
(forced ventilation)
Load break switches
Vacuum Contactors (inductive switching)
Vacuum Contactors (capacitive switching)
Rated short time withstand (rms) current with
C/B and Disconnectors
Load break switches
Vacuum Contactors
Rated short time withstand (peak) current with
C/B and Disconnectors
Load break switches
Vacuum Contactors
Short circuit withstand time
up to 31.5 kV
above 31.5 kV
Internal Arc withstand
SMC 3,6
SMC 7,2
SMC 12
SMC 17,5
SMC 24
SMC 36
SMC 40,5
kV
3,6
7,2
12
17,5
24
36
40,5
kV
10
20
28
38
50
70
85
kV
40
60
75
95
125
170
185
50 - 60
Hz
A
A
A
A
A
A
A
630 ... 3150
5000
630 ... 3150
5000
630
400
250
630 ... 3150
5000
630 ... 3150
5000
630
800
200
630 ... 3150
5000
630 ... 3150
5000
630
-
16 ... 50
16 - 20
8
16 ... 50
16 - 20
8
16 ... 50
16 - 20
-
40 ... 125
40 - 50
20
40 ... 125
40 - 50
20
40 ... 125
40 - 50
-
3
1
3
1
3
1
16 ... 31.5
1
16 ... 31.5
1
16 ... 31.5
1
16 ... 50
3
1
16 ... 50
3
1
16 ... 50
3
1
kA
kA
kA
kA
kA
kA
s
s
Current kA
Duration s
Earthing Disconnector
Rated short time withstand current kA
Duration (up to 31.5 kA) s
(above 31.5 kA) s
Switchgear Structure as per the
loss of service continuity
internal arc classification
partition class
LSC 2B
AFLR
PM
Protection Class
when doors are closed - standard
optional
between compartments
Color
IP 40
IP 42
IP 20
RAL 9003 / 7035
IEC 62271-200
Standards complied
56
a Friem & Aktif Group Company
SMC series Metal Clad Switchgears
C
C 2.6 Switchgears Types
Double Bus Incoming/Outgoing Switchgear
Double Bus
Incoming / Outgoing
Double Bus
Coupling
Is the switchgear with rated current up to 3150 A and short
circuit current up to 50 kA where the power incoming and
outgoing realized by busbar and switching operation can be
realized in short circuit situation.
Double Bus Coupling Switchgear
Is the switchgear with rated current up to 3150 A and short
circuit current up to 50 kA where the energy is supplied from
two different sources.
Double Bus Voltage Measuring Switchgear
Double Bus
Voltage Measuring
It is used for obtaining voltage information for the measurement
and protection purposes in the metal clad busbar with rated
current up to 3150 A and short circuit current up to 50 kA
with the help of Secondary relays and measurement devices
such as Voltmeter, analyzers and Electricity Meters.
Double Bus
Current & Voltage
Measuring
Double Bus Current & Voltage Measuring Switchgear
Switchgear with rated current up to 3150 A and short circuit
current up to 50 kA in which the current and voltage
information of the distribution busbars are obtained by using
Secondary protection relays and measurement devices such
as Ammeter, Voltmeter, Analyzers and Electricity Meters.
57
a Friem & Aktif Group Company
C
SMC series Metal Clad Switchgears
C 2.6.1 Double Bus Incoming / Outgoing Switchgears
Is the switchgear with rated current up to 3150 A and short circuit
current up to 50 kA where the energy incoming and outgoing
realized by busbar and switching operation can be realized in the
short circuit situation, with full protection frame.
Switching operation is realized by vacuum or SF6 gas insulated
Circuit Breaker with 3 poles. The disconnecting operation is
realized when withdrawable truck with the busbar on it shall be
turned to the test position. The Bus connection is changed by lift.
Incoming Switchgear with Circuit Breaker is used in;
- Distribution Busbars of Network and Generator Incoming
feeders
- Any Load supply feeders of Distribution Busbars and
- Incoming and Outgoing of Open/Close Ring operated Networks.
Switchgear Equipment
X
TRIP
Imax
Uab
VA
OPEN
RCL
LRC
0 A0 V
POWER
CLOSED
0.00 k
Disable
Not Avail
<Menu>
<<<
<<<
I
O
RS232
Withdrawable Circuit Breaker
Earthing Disconnector
Thermostat and Heater Kit
Copper Busbar
Capacitive Voltage Indicator Set
Surge Arrestor
Voltage Transformer
Voltmeter Commutator Set
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Over Current Relay
Other secondary protection relays
Test Terminal
Cable Connection Terminal
SCADA Connections
GSM-GPRS Modem Converter Set
Interlock
Rated Voltage (kV)
3.6 - 24
36 - 40.5
58
a Friem & Aktif Group Company
Standard
x
x
x
x
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
Switchgear Dimensions
Width (mm)
Depth (mm)
Height (mm)
800
2350
2100
1200
3500
2450
SMC series Metal Clad Switchgears
C 2.6.2 Double Bus Coupling Switchgear
Is the switchgear with rated current up to 3150 A and short circuit
current up to 50 kA where the energy is supplied from two different
sources, with full protection frame.
Switching operation is realized by Vacuum or SF6 gas insulated
Circuit Breaker with 3 poles. The disconnecting operation is realized
when withdrawable truck with the busbar on it shall be turned to the
test position.
Double Bas Coupling Switchgears are used to connect two
Busbars automatically or with local/remote switching operation.
Switchgear Equipment
X
TRIP
Imax
Uab
VA
OPEN
RCL
LRC
0 A0 V
POWER
CLOSED
0.00 k
Disable
Not Avail
<Menu>
<<<
<<<
I
O
RS232
Withdrawable Circuit Breaker
Earthing Disconnector
Thermostat and Heater Kit
Copper Busbar
Current Transformer
Ammeter
Power Analyzer
Electricity Meter
Over Current Relay
Other secondary protection relays
Test Terminal
SCADA Connections
GSM-GPRS Modem Converter Set
Interlock
Rated Voltage (kV)
3.6 - 24
36 - 40.5
Standard
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
Switchgear Dimensions
Width (mm)
Depth (mm)
Height (mm)
800
2350
2100
1200
3500
2450
59
a Friem & Aktif Group Company
C
C
SMC series Metal Clad Switchgears
C 2.6.3 Double Bus Voltage Measuring Switchgears
Switchgear is used for obtaining voltage information for the
measurement and protection purposes in the metal clad
busbar with rated current up to 3150 A and short circuit
current up to 50 kA with the help of Secondary protection
relays and measurement devices like Voltmeter, Power
Analyzers, Electricity meters, etc ...
Disconnection is realized by the turning of the unit in to the
test position.
Bus Voltage Measuring Switchgears are used in :
- Measurement and protection basis Voltage data reading.
- Billing basis Energy consumption measurement.
- Providing auxiliary power up to 2.5 kVA in Low Voltage.
Switchgear Equipment
Thermostat and Heater Kit
Copper Busbar
Medium Voltage Fuses
Voltage Transformer
Voltmeter and Commutator Set
Power Analyzer
SCADA Connections
Interlock
Rated Voltage (kV)
3.6 - 24
36 - 40.5
60
a Friem & Aktif Group Company
Standard
x
x
x
x
Options
x
x
x
x
Switchgear Dimensions
Width (mm)
Depth (mm)
Height (mm)
800
2350
2100
1200
3500
2450
SMC series Metal Clad Switchgears
C 2.6.4 Double Bus Current & Voltage Measuring
Switchgears
Switchgear with rated current up to 3150 A and short circuit
current up to 50 kA in which the current and voltage
information of the distribution busbars are obtained by using
Secondary protection relays and measurement devices such
as Ammeter, Voltmeter, Analyzers and Electricity Meters.
Disconnecting operation is not requested in such kind of
feeders to be able to measure the energy consumption
continuously.
Metering Switchgears are used for the receiving of;
- Main Measurement basis Current and Voltage data.
- Billing basis Energy consumption measurement.
Switchgear Equipment
Thermostat and Heater Kit
Copper Busbar
Medium Voltage Fuses
Voltage Transformer
Voltmeter and Commutator Set
Power Analyzer
SCADA Connections
Interlock
Rated Voltage (kV)
3.6 - 24
36 - 40.5
Standard
x
x
x
x
Options
x
x
x
x
Switchgear Dimensions
Width (mm)
Depth (mm)
Height (mm)
800
2350
2100
1200
3500
2450
61
a Friem & Aktif Group Company
C
D1
D2
D3
D4
D5
D6
Compartments
Application Areas
Advantages
Standards Complied
Technical Specifications
Switchgears Types
D 6.1 L type Line Disconnecting Unit
D 6.2 F type Transformer Protection Unit with Circuit Breaker
D 6.3 E type Cable Connection Unit with Earthing Disconnector
D 6.4 T type 200 A Transformer Protection Unit with Circuit Breaker
D 6.5 C type 630 A or 1250 A Line Protection Unit with Circuit Breaker
D 6.6 U1 / U3 type 630 A Bus Coupling Unit with Disconnector
D 6.7 U2 type 630 A Bus Coupling Unit with Disconnector
D 6.8 UCB type 630 A Bus Coupling Unit with Disconnector
D 6.9 Q type Measurement Unit with Circuit Breaker
D 6.10 M type Measurement Unit
D 7 Sample Busbar Designs with RMU
62
65
65
66
66
67
69
70
71
72
73
74
75
76
77
78
79
80
Gas
Insulated
RMUs
D
TPR6 series Gas Insulated RMUs
TPR6 series gas insulated modular RMUs are the switching
and control Switchgears are manufactured in conformity
with IEC 62271-200 standards.
TPR6 series gas insulated RMUs are used on the medium voltage
distribution busbars with rated voltage from 1 kV to 40.5 kV, with
the rated current from 200 A up to 1250 A and short time withstand
current up to 25 kA.
TPR6 series gas Insulated RMUs are defined with following
features:
Gas Insulated
Partition Class PM
AFL and AFLR Internal Arc Classification
64
a Friem & Aktif Group Company
TPR6 series Gas Insulated RMUs
D 1 Compartments
b
a- Switching Equipment Compartment
b- Low Voltage Command Compartment
a- Switching Equipment Compartment
TPR6 is a “lifelong closed section” that contains all
Switching Equipment and live parts along with its stainless
steel tank. It is separated from environment with a hermetic
enclosed steel tank and provides very high level of safety for
humans. The structure is designed to stand electro-dynamic
stress while it is working.
The working mechanism, dynamic mimic diagram and
voltage signal lamps are located on the front panel.
Switching operations are performed with spring
mechanisms.
The positions of the Switching Equipment are shown on the
dynamic mimic diagram and voltage status can be monitored
with capacitive voltage indicator. The circuit breaker and
cable compartment is placed in an easily accessible way
from the front door which can be locked with a ground key.
b- Low Voltage Compartment
The low voltagecompartment is added up on the panel as a
separate unit.
a
D 2 Application Areas
TPR6 series Switchgears are used due to their compact sizes in
small spaces in transformer stations, and distribution facilities
at especially premier disruption level.
Energy Transmission Centers
Hydroelectric and Wind Energy Applications
Diesel and Natural Gas Power Plants
Transformer Stations
Cement Factories
Auto Industry
Petroleum Industry
Chemical Industry
Iron and Steel Industry
Rolling Mills
Pipelines
Electro-Chemical Facilities
Emergency Situation and Stand-by Power Facilities
Ore Mines
Rail Systems
65
a Friem & Aktif Group Company
D
D
TPR6 series Gas Insulated RMUs
D 3 Advantages
Grounded metal separation between the sections
Maximum human safety with AFL and AFRL internal arc
testing feature
Safe electrical and mechanical Interlock systems do not
permit for operational faults
Grounding system with ensured continuity
Modular design, allowing additions to the system
Tested short time withstand current is 21 kA.
Interactive mimic diagram
Proven reliability with unique design for the operation and
personnel safety
No maintenance requirement
Suitable for remote monitoring and remote applications
No need for addition of SF6 gas for 30 years due to the
sealing
Working without being effected from humid, dusty and dirty
environments.
D 4 Standards Complied
The RMU series Switchgears are manufactured in
conforming to the following standards:
IEC 62271-1
IEC 62271-200
IEC 62271-100
IEC 62271-102
IEC 62271-105
IEC 60044-1
IEC 60044-2
IEC 60273
IEC 60051
IEC 60255
66
a Friem & Aktif Group Company
: General articles relating to high voltage
Switchgears
: Metal enclosed Switchgears (1 - 52 kVac)
: Breakers (1 - 52 kVac)
: Main Circuit and Grounding Separators
: AC Switching and Circuit Breaker
Combinations
: Current Transformers
: Voltage Transformers
: Insulators
: Measuring Devices
: Secondary Protection relays
TPR6 series Gas Insulated RMUs
D 5 Technical Specifications
Technical Specifications
Descriptions
Rated Voltage (rms)
Power frequency withstand Voltage 50 Hz, 1 min
(rms) between phases
Power frequency withstand Voltage 50 Hz, 1 min
(rms) phase to ground
Lightning impulse withstand voltage 1.2/50 ms
(peak) between phases
Lightning impulse withstand voltage 1.2/50 ms
(peak) phase to ground
Rated frequency
Rated current
Rated short time withstand current (I k)
Rated duration of short circuit (tk)
Rated peak withstand current (making capacity)
Protection degree (front side)
Protection degree (M.V. compartment)
Internal arc withstand current
Making & Breaking on fuse switch (F module)
Rated transfer current at breaking (F module)
Active load breaking current (disconnectors)
Closed loop breaking current (disconnectors)
No-load transformer breaking current (disconnectors)
Cable charging breaking current (disconnectors)
Line charging breaking current (disconnectors)
Earth fault breaking current (disconnectors)
Number of Mechanical operations (disconnectors)
Number of Electrical operations (disconnectors)
Number of Mechanical operations
(earthing switch)
Number of Electrical operations
(earthing switch)
Number of Mechanical operations
(C module circuit breaker)
Number of Electrical operations
(C module circuit breaker)
Number of Mechanical operations
(T module circuit breaker)
Number of Electrical operations
(T module circuit breaker)
Sequence of process (for Circuit Breaker)
Maximum ambient temperature
Allowed temperature difference
Minimum ambient temperature
Relative humidity
Altitude (max.)
Color
TPR6 7,2
TPR6 12
TPR6 12*
TPR6 17,5
TPR6 24
TPR6 36
TPR6 40,5
kV
7,2
12
12
17,5
24
36
40,5
kV
20
28
42
38
50
70
95
kV
23
32
48
45
60
80
110
kV
60
75
95
95
125
170
185
kV
Hz
A
kA
s
kA
IP
IP
kA
kA
A
A
A
A
A
A
A
70
85
110
145
50 - 60
630 - 1250
16-20-25
3
2,5 x Ik
3x
67
16 - 20
25
25
20
1800
1600
1400
630
630
16
32
32
57
1,000 op. / M1 cl.
100 op. at P.F.= 0.7 / E3 cl.
195
210
25
2100
25
1800
110
12,5-16-20
20
840
20
840
1.000 op. / M1 cl.
Making capacity x 5 / E2 cl.
10,000 op. / M2 cl.
E2 cl.
2,000 op. / M1 cl.
E1 cl.
O - 0,3 s - CO - 3 min - CO
55 oC
40 oC
-25 oC
% 95
1000 m.
RAL 9003
Note: Full type tests of TPR6 switchgears up to 25 kA are performed at CESI accredited laboratories in Italy.
67
a Friem & Aktif Group Company
D
D
TPR6 series Gas Insulated RMUs
Operational Mechanism Options
Rated Voltage
Up to 24 kV
36 kV - 40.5 kV
Unit Type
L*
F
C
T
U1 *
U2
E
M
I
L*
F
C
U1 *
U2
E
M
I
Q
Avaiable Options
No enlargement from right or left
Enlargement is possible
Cable entry or exit from the side
Cable entry or exit from the side
Busbar or cable entry exit from the top
Disconnector
-
-
0
+
I
B
K
Earthing Disconnector
LT
3D
CB6
CB6
LT
CB6
E
**
LT
3D
LT
LT
LT
E
LT
Circuit Breaker
TCB
TCB
TCB
TPR6 RMU units are used in any type connection like
disconnector - fuse combination, disconnector - circuit
breaker combination; in protection with secondary
protection relays and metering in MV.
Mechanism types in TRP6 series RMUs are as below.
D 5.1 CB6 and TCB6 type Circuit Breaker
Mechanism
For circuit breaker applications of TPR6 series RMUs with
rated current of 200 A and 630 A, CB6 type circuit breakers
are used up to rated voltage 24 kV and TCB type circuit
breakers are used above rated voltage 24 kV.
D 5.2 LT Type Disconnector Mechanisms
LT type separator
mechanism
3D type separator
mechanism
This type of disconnector mechanisms are used L, U2, Q and
U2 modules of TPR6 series RMUs only in 36 and 40.5 kV
rated voltages.
D 5.3 3D Type Disconnector Mechanisms
This type of disconnector mechanisms are used in circuit
breakers with shunt opening coil of F module.
D 5.4 Mechanism Selection
* Every letter below the unit describes the function of the
module. Units may expandable from left, right or both sides
in option “L”, and from top in option “K” with the connection
of cables or busbars.
CB6 type breaker
mechanism
** Option B is the same of option “l” but the cable
connection is not inside a metal housing.
68
a Friem & Aktif Group Company
TPR6 series Gas Insulated RMUs
D 6 RMU Types
L type
Line Disconnector
F type Transformer
Protection with
Circuit Breaker
L type Line Disconnector Unit
E type Cable
Connection with
Earthing Disconnector
It is used as line in with disconnector in the distributions
centers where RMU units are utilized.
F type Transformer Protection Unit with Circuit Breaker
It is used in the distribution centers with a circuit breaker
disconnector, where RMU is utilized, for the purpose of
protection of transformers with capacity of up to 400 kVA
or up to 1600 kVA, providing that it is located in the same
place.
E type Cable Connection Unit with Earthing Disconnector
T type Transformer
Protection with
200 A Circuit Breaker
C type
Line Protection with
630 A Circuit Breaker
In the distribution centers where RMU is used, it is utilized
for making an entry to the RMU busbar without needing
any switching element.
U1 type
Bus Coupling with
630 A Disconnector
T type Transformer Protection Unit with 200 A Disconnector
In the distribution centers where RMU is used, it is utilized
for the protection of transformers with a 200 A Circuit
Breaker and secondary protection relays.
C type Line Protection Unit with 630 A Circuit Breaker
In the distribution centers where RMU is used, it is utilized
for the protection of lines with a 630 A Circuit Breaker and
secondary protection relays.
U1 type Bus Coupling Unit with 630 A Disconnector
U2 type
Bus Coupling with
630 A Circuit Breaker
U3 type
Bus Coupling with
630 A Disconnector
In the distribution centers where RMU is used, it is utilized
for connecting two RMU busbars without secondary
protection but with 630 A disconnector.
UCB type
Bus Coupling with
630 A Circuit Breaker
U2 type Bus Coupling Unit with 630 A Circuit Breaker
In the distribution centers where RMU is used, it is utilized
for connecting two RMU busbars with secondary protection
with 630 A Circuit Breaker and disconnector by providing
earthing option.
U3 type Bus Coupling Unit with 630 A Disconnector
In the distribution centers where RMU is used, it is utilized
for connecting two RMU busbars without protection but
with 630 A disconnector and earthing disconnector.
UCB type Bus Coupling Unit with 630 A Circuit Breaker
Q type
Measuring with
Circuit Breaker (for 36 kV)
M type
Measuring
In the distribution centers where RMU is used, it is utilized
for connecting two RMU busbars with secondary protection
with 630 A Circuit Breaker.
Q type Measuring Unit with Circuit Breaker (for 36 kV)
These are the RMU units that contain the meter for the
invoicing purposes only at 36 kV level in distribution
centers where a RMU is used.
M type Measuring Unit
These are the units that contain the meter for the invoicing
purposes in distribution centers where a RMU is used.
69
a Friem & Aktif Group Company
D
D
TPR6 series Gas Insulated RMUs
D 6.1 L type
Line Disconnector Unit
It is used within the open or closed ring structure of the wind
mill Power Plants, energy distribution companies and
factories that have number of scattered transformers and
also within the RMU medium voltage distribution centers of
energy distribution systems as a ring Incoming Outgoing unit
which is not considered to be need for secondary protection.
When the Disconnector mechanism is selected with a motor,
remote opening and closing process can be carried out.
The L type RMU can be selected to permit expansion to the
right or left. Furthermore, cable and busbar connection
from the top is also possible.
Switchgear Equipment
Pressure Gage
LT Type Operating Mechanism
Capacitive Voltage Indicator Set
3D Type Operating Mechanism*
Opening Disconnector Coil (for 3D Type)
Disconnector auxiliary contacts
Earthing Disconnector auxiliary contacts
Motor for Disconnector spring
Charging
Disconnector Interlock (Open)
Earthing Disconnector Interlock (Close)
Other secondary protection relay
Disconnector Key Lock
Earthing Disconnector Key Lock
LV Control Panel
Short Circuit Lamp Indicator
Earthing Fault Lamp Indicator
K
0
0
+
+
I
I
*
Standard
x
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
It is alternative of LT type Operating Mechanism
Switchgear Dimensions
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
Rated Voltage (kV)
1 - 24
36 - 40.5
0
+
I
K
*
70
a Friem & Aktif Group Company
Width (mm)
350
425
Depth (mm)
717
912
Height (mm)
1200 / 1500 *
1830
Height of the unit is 1500mm when used together with a C Type module
TPR6 series Gas Insulated RMUs
D 6.2 F type
Transformer Protection Unit with Circuit
Breaker
While providing protection, it is used for feeding the
transformers from the medium voltage distribution centers
with RMU at energy distribution systems of medium voltage
that have open or close ring structured.
When the Disconnector mechanism is selected with a motor,
remote opening and closing process can be carried out.
The F type RMU can be selected to permit expansion to the
right or left. Furthermore, cable and busbar connection
from the top is also possible.
Switchgear Equipment
Pressure Gage
Capacitive Voltage Indicator Set
3D Type Operating Mechanism *
Opening Disconnector Coil (for 3D Type)
Disconnector auxiliary contacts
Earthing Disconnector auxiliary contacts
Motor for Disconnector spring Charging
Disconnector Interlock (Open)
Earthing Disconnector Interlock (Close)
Other secondary protection relay
Disconnector Key Lock
Earthing Disconnector Key Lock
LV Control Panel
Short Circuit Lamp Indicator
Earthing Fault Indicator Lamp
K
0
0
+
+
I
I
*
Standard
x
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
It is alternative of LT type Operating Mechanism
Switchgear Dimensions
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
Rated Voltage (kV)
1 - 24
36 - 40.5
0
+
I
K
*
Width (mm)
350
425
Depth (mm)
717
912
Height (mm)
1200 / 1500 *
1830
Height of the unit is 1500mm when used together with a C Type module
71
a Friem & Aktif Group Company
D
D
TPR6 series Gas Insulated RMUs
D 6.3 E type
Cable Connection Unit with Earthing Disconnector
It is used for making Incoming with a cable to a busbar that
does not need switching element in up to 24 kV medium
voltage RMU distribution busbars.
The E type RMU can be selected to permit expansion to the
right or left. Furthermore, cable and busbar connection
from the top is also possible.
Switchgear Equipment
Pressure Gage
Capacitive Voltage Indicator Set
Earthing Disconnector Key Lock
LV Control Panel
Surge Arrester
Short Circuit Lamp Indicator
Earthing Fault Lamp Indicator
K
0
0
+
+
I
I
Standard
x
x
Options
x
x
x
x
x
Switchgear Dimensions
Rated Voltage (kV)
1 - 24
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
*
0
+
I
K
72
a Friem & Aktif Group Company
Width (mm)
350
Depth (mm)
717
Height (mm)
1200 / 1500 *
Height of the unit is 1500mm when used together with a C Type module
TPR6 series Gas Insulated RMUs
D 6.4 T type
Transformer Protection Unit with 200 A
Disconnector
It is used in medium voltage open or closed ring distribution
structures with up to 24 kV RMU units for feeding
transformers while ensuring protection with 200 A Circuit
Breaker and secondary protection relay from medium
voltage distribution center.
The T type RMU can be selected to permit expansion to the
right or left. Furthermore, cable and busbar connection
from the top is also possible.
Switchgear Equipment
Pressure Gage
Capacitive Voltage Indicator Set
CB6 Type Operating Mechanism*
200 A Vacuum Breaker
Circuit reaker Opening Relay
Circuit Breaker auxiliary contacts
Circuit Breaker central Interlock system*
Disconnector auxiliary contacts
Earthing Disconnector auxiliary contacts
Disconnector Interlock (Open)
Earthing Disconnector Interlock (Open)
Earthing Disconnector Interlock (Close)
Disconnector Key Lock
Earthing Disconnector Key Lock
Secondary protection relay
Low Voltage relay
Breaker Engine for setting the spring
Breaker Closing Relay
LV Control Panel
Short Circuit Lamp Indicator
Earthing Fault Lamp Indicator
Current Transformer Cable Connection
K
0
0
+
+
I
I
*
Standard
x
x
x
x
x
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
when the Disconnector is off and breaker is on, lock key can be moved
Switchgear Dimensions
Rated Voltage (kV)
1 - 24
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
*
Width (mm)
350
Depth (mm)
717
Height (mm)
1200 / 1500 *
Height of the unit is 1500mm when used together with a C Type module
0
+
I
K
73
a Friem & Aktif Group Company
D
D
TPR6 series Gas Insulated RMUs
D 6.5 C type
Line Protection Unit with 630 A or 1250 Circuit
Breaker
It is used in medium voltage open or closed ring distribution
structures with the RMU units for line Incoming of the
medium voltage distribution centers with 630 A or 1250 A
Circuit Breaker and secondary protection relay to ensure
busbar Incoming.
The C type RMU can be selected to permit expansion to the
right or left. Furthermore, cable and busbar connection
from the top is also possible.
Switchgear Equipment
Pressure Gage
Capacitive Voltage Indicator Set
CB6 Type Operating Mechanism *
630A/1250A Vacuum Breaker
Breaker Opening Relay
Breaker auxiliary contacts
Breaker central Interlock system *
Disconnector auxiliary contacts
Earthing Disconnector auxiliary contacts
Disconnector Interlock (Open)
Earthing Disconnector Interlock (Open)
Earthing Disconnector Interlock (Close)
Disconnector Key Lock
Earthing Disconnector Key Lock
Secondary protection relay
Low Voltage relay
motor for Disconnector spring Charging
Breaker Closing Relay
LV Control Panel
Short Circuit Lamp Indicator
Earthing Fault Lamp Indicator
Current Transformer Cable Connection
K
0
0
+
+
I
I
*
Standart
x
x
x
x
x
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
when the Disconnector is off and breaker is on, lock key can be moved
Switchgear Dimensions (for 630 A)
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
Rated Voltage (kV)
1 - 24
36 - 40.5
0
+
I
K
*
Depth (mm)
717
912
Height (mm)
1500
1830
Height of the unit is 1500mm when used together with a C Type module
Switchgear Dimensions (for 1250 A)
Rated Voltage (kV)
1 - 24
*
74
a Friem & Aktif Group Company
Width (mm)
350
425
Width (mm)
600
Depth (mm)
717 / 1000
K type upper expansion option can only be possible by use of a bar.
Height (mm)
1800 / 2250 *
TPR6 series Gas Insulated RMUs
D 6.6 U1 / U3 type
Bus Coupling Unit with 630 A Disconnector
It is used with the RMU units in medium voltage open or
closed ring distribution structures' medium voltage
distribution centers for the purpose of connecting two
different busbars with Disconnector and Load Break Switch.
Earthing disconnector option is supplied by U3 type switchgear.
The U1 type RMU can be selected to permit expansion to the
right or left. Furthermore, cable and busbar connection
from the top is also possible.
U1
U3
Switchgear Equipment
0
0
+
+
K
K
Pressure Gage
Capacitive Voltage Indicator Set
LT Type Operating Mechanism
Opening Disconnector Coil (for 3D Type)
Disconnector auxiliary contacts
Earthing Disconnector
Earthing Disconnector auxiliary contacts
motor for Disconnector spring Charging:
(for type 3D)
Disconnector Interlock (Open)
Earthing Disconnector Interlock (Open)
Earthing Disconnector Interlock (Close)
Disconnector Key Lock
Earthing Disconnector Key Lock
LV Control Panel
Short Circuit Lamp Indicator
Earthing Fault Lamp Indicator
Standard
x
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
* The alternative mechanism for LT type Disconnector mechanism can be used in case
a 3D type mechanism is used.
Switchgear Dimensions (for 630 A)
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
Rated Voltage (kV)
1 - 24
36 - 40.5
0
+
I
K
*
*
Width (mm)
450**
625
Depth (mm)
717
912
Height (mm)
1200 / 1500*
1830
Height of the unit is 1500mm when used together with a C Type module:
In case an expansion will not be made, the width is 350 mm.:
75
a Friem & Aktif Group Company
D
D
TPR6 series Gas Insulated RMUs
D 6.7 U2 type
Bus Coupling Unit with 630 A Circuit Breaker
It is used with the RMU units in medium voltage open or
closed ring distribution structures' medium voltage
distribution centers for the purpose of connecting two
different busbars with Disconnector or Load Break Switch
and Circuit Breaker contains secondary protection function.
The U2 type RMU can be selected to permit expansion to the
right or left. Furthermore, cable and busbar connection
from the top is also possible.
Switchgear Equipment
0
0
+
+
K
K
Pressure Gage
Capacitive Voltage Indicator Set
LT + TCB Type Operating Mechanism
630A/1250A Vacuum Breaker
Breaker Opening Relay
Breaker auxiliary contacts
Breaker central Interlock system*
Disconnector auxiliary contacts
Earthing Disconnector auxiliary contacts
Disconnector Interlock (Open)
Earthing Disconnector Interlock (Open)
Earthing Disconnector Interlock (Close)
Disconnector Key Lock
Earthing Disconnector Key Lock
Secondary protection relay
Low Voltage relay
Breaker Engine for setting the spring:
Breaker Closing Relay
LV Control Panel
Short Circuit Lamp Indicator
Earthing Fault Lamp Indicator
*
Standard
x
x
x
x
x
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
when the Disconnector is off and breaker is on, lock key can be moved.
Switchgear Dimensions (for 630 A)
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
Rated Voltage (kV)
1 - 24
36 - 40.5
0
+
I
K
*
Depth (mm)
717
912
Height (mm)
1200 / 1500
1830
Height of the unit is 1500 mm when used together with a C Type module
Switchgear Dimensions (for 1250 A) **
Rated Voltage (kV)
1 - 24
**
76
a Friem & Aktif Group Company
Width (mm)
450
750
Width (mm)
600
Depth (mm)
717 / 1000
K type upper expansion option can only be possible by use of a bar.
Height (mm)
1500 / 2250 *
TPR6 series Gas Insulated RMUs
D 6.8 UCB type
Bus Coupling Unit with 630 A Circuit Breaker
It is used with the RMU units in medium voltage open or
closed ring distribution structures' medium voltage
distribution centers for the purpose of connecting two
different busbars with Circuit Breaker and secondary
protection relay.
The UCB type RMU can be selected to permit expansion to
the right or left. Furthermore, cable and busbar connection
from the top is also possible.
Switchgear Equipment
0
0
+
+
K
K
Pressure Gage
Capacitive Voltage Indicator Set
CB6 Type Operating Mechanism
630A/1250A Vacuum Breaker
Breaker Opening Relay
Breaker auxiliary contacts
Breaker central Interlock system*
Secondary protection relay
Low Voltage relay
motor for C.B spring Charging
Breaker Closing Relay
LV Control Panel
Short Circuit Lamp Indicator
Earthing Fault Lamp Indicator
*
Standard
x
x
x
x
x
x
Options
x
x
x
x
x
x
x
x
when the breaker is on, lock key can be moved.
Switchgear Dimensions (for 630 A)
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
Rated Voltage (kV)
1 - 24
36 - 40.5
0
+
I
K
*
Width (mm)
450
750
Depth (mm)
717
912
Height (mm)
1200 / 1500
1830
Height of the unit is 1500 mm when used together with a C Type module
Switchgear Dimensions (for 1250 A) **
Rated Voltage (kV)
1 - 24
**
Width (mm)
600
Depth (mm)
717 / 1000
Height (mm)
1500 / 2250 *
K type upper expansion option can only be possible by use of a bar.
77
a Friem & Aktif Group Company
D
D
TPR6 series Gas Insulated RMUs
D 6.9 Q type
Measuring Unit with Circuit Breaker (for 36 kV)
It is used with the RMU units in medium voltage open or
closed ring distribution structures' medium voltage
distribution centers for the purpose of measurement of
electricity consumption at the busbar by entering to the
busbar by a cable or another busbar.
A cable or busbar connection to a Q Type RMU from the top
is possible.
Switchgear Equipment
Pressure Gage
Capacitive Voltage Indicator Set
LT + TCB Type Operating Mechanism
630A/1250A Vacuum Breaker
Breaker Opening Relay
Breaker auxiliary contacts
Breaker central Interlock system*
Disconnector auxiliary contacts
Earthing Disconnector auxiliary contacts
Disconnector Interlock (Open)
Earthing Disconnector Interlock (Open)
Earthing Disconnector Interlock (Close)
Disconnector Key Lock
Earthing Disconnector Key Lock
Secondary protection relay
Low Voltage relay
motor for Circuit Breaker spring Charging
Breaker Closing Relay
LV Control Panel
Short Circuit Lamp
Earthing Fault Lamp Indicator
Current Transformer Cable Connection
Current Transformer
Voltage Transformer
K
*
Standard
x
x
x
x
x
x
x
Options
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
when the Disconnector is off and breaker is on, lock key can be moved.
Switchgear Dimensions (for 630 A)
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
Rated Voltage (kV)
36
0
+
I
K
*
78
a Friem & Aktif Group Company
Width (mm)
1000
Except the upper bar section
Depth (mm)
1150
Height (mm)
1830 *
TPR6 series Gas Insulated RMUs
D 6.10 M type
Measuring Unit
It is used with the RMU units in medium voltage open or
closed ring distribution structures' medium voltage
distribution centers for the purpose of measurement of
electricity consumption at the busbar.
The M type RMU can be selected to permit expansion to the
right or left. Busbar connection to a M Type RMU from the
top is possible.
Switchgear Equipment
0
0
+
+
K
K
Connection Bushings
Current Transformer Mounting plate
Voltage Transformer Mounting plate
1 or 2 piece Electric Connection Kit
No 2-3 Current Transformer
No 2-3 Voltage Transformer
LV Control Panel
Fuse and Fuse-Box
Standard
x
x
x
Options
x
x
x
x
x
Switchgear Dimensions (for 630A)
Avaiable Options
Not expandable to the right or left
Expandable
Side Cable Entry and Outlet
Busbar or cable entry-outlet from the top
Rated Voltage (kV)
1 - 24
36 - 40.5
Width (mm)
850
1100
Depth (mm)
717
1150
Height (mm)
1200
1830
0
+
I
K
79
a Friem & Aktif Group Company
D
D
TPR6 series Gas Insulated RMUs
D 7 Sample Busbar Design with RMU
0L
L
L
F0
Sample 1 :
A medium voltage busbar with 1 Incoming and 3 Outgoings, not
expanding to the right or left, consisting of L type Incoming unit
with a load separator (not expandable to the right) where
busbar Incoming is made and 2 L type Outgoing units with a F
type unit (no expandable to the right).
With the notation of “0 L”, it is stated that the far most left hand
side L type unit cannot be expanded to the left and similarly
with “F 0”, the far right hand side F type Switchgears will not
expand to the right.
Sample 1
+L
L
F
F+
Sample 2 :
A medium voltage busbar with 1 Incoming and 3 Outgoings,
expandable to the right and left, consisting of L type Incoming
unit with load separator (expendable to the left) where busbar
Incoming is made and 2 F type unit (expendable to the right).
With the notation of “+ L”, it is stated that the far most left hand
side L type unit can be expanded to the left and similarly with
“F +”, the far right hand side F type Switchgears can be
expanded to the right.
Sample 2
I
F0
Sample 3 :
A circuit breaker protection solution is derived with an F type
unit that could not expand o the right hand side, by direct cable
connection module for energy feeding.
With the notation of “F O”, it is stated that the left hand side F
type unit cannot be expanded.
Sample 3
80
a Friem & Aktif Group Company
TPR6 series Gas Insulated RMUs
0L
L+
M
+F
F0
Sample 4 :
Busbar Incoming is performed with L type Incoming unit with
load separator (not expandable to the left) and Outgoing is
realized with 1 L type unit (expandable to the right) and in
addition, one M unit added to the busbar. It is a busbar solution
by addition of an F unit that is extendable to the left on the right
hand side, and addition of 2 F type not extendable units to the
left hand side of the busbar.
With the notation of “0 L”, it is stated that the far most left hand
side L type unit cannot be expanded to the left and similarly
with “L +”, the far right hand side L type Switchgears can be
expanded to the right and with “+ F” notation, it is shown that
the additional unit on the left can be added to the medium
voltage busbar from the far right hand side and with “F 0”
notation it is indicated that the far right hand side Switchgears
can be expanded from its right hand side.
Sample 4
0L LK
OF FK
OF FK
Sample 5 :
This is a sample application of connecting three medium
voltage busbar composed of two units are connected with a
cable or busbar overhead.
Sample 5
0L
L
FO
M
In the first busbar “0 L” coded unit describes that the unit with
a load separator cannot be expanded to the left and the unit
with “L K” is an Outgoing unit that can be connected with a
cable or busbar.
The units with the notation of “0 L” on the second and third
busbars indicates these unites that are protected by load
separator circuit breaker are not expandable to the left, and “F
K” notation shows that these load separator circuit breaker
protected transformers can have Outgoing with cable or a
busbar from the top.
Sample 6 :
In this sample, the energy has been transferred to a busbar by
an L unit which has a load separator and is not expandable to
the right and one Outgoing is secured by an L unit which does
not expand to the right and has a load separator as well as two
Outgoings by an F unit that has a load separator circuit breaker
and does not expand to the right.
Sample 6
In this sample, it is noted that the unit with “0 L” code cannot
expand to the left and has Incoming-Outgoing with a load
separator, “L” denotes Incoming-Outgoing with load separator
with no expandability either to the right or left, whereas the unit
that has "F 0" indicates that it is a Incoming-Outgoing unit with
circuit breaker and load separator and it does not expand to the
right. The unit with an “M” code is a measurement unit that
does not expand to the right or left and the Incoming or
Outgoing is only performed by a cable.
81
a Friem & Aktif Group Company
D
E 1 Switching Equipment
E 1.1 Circuit Breakers
E 1.1.1 SVC Series Vacuum Circuit Breakers
E 1.1.2 SION/3AH (Siemens) Vacuum Circuit Breakers
E 1.1.3 EVOLIS (Schneider) Vacuum Circuit Breakers
E 1.1.4 SF1 (Schneider) SF6 Gas Circuit Breakers
E 1.1.5 SF2 (Schneider) SF6 Gas Circuit Breakers
E 1.2 Vacuum Contactors
E 1.3 LBS and Disconnectors
E 2 Protection Devices
E 2.1 Relays
E 2.1.1 M series Digital Protection Relays
E 2.1.2 MC series Digital Protection Relays
E 2.1.3 ULTRA series Protection Relays
E 2.1.4 DTVA series Distance Protection Relays
E 2.1.5 ANSI codes Relay Application Table
E 2.1.6 Relay Management Software
E 2.2 Circuit Breakers
E 3 Measuring Devices
E 3.1 Capacitive Voltage Indicators
E 3.2 Analyzers
E 3.2.1 NQM series Energy Analyzers
E 3.2.2 NPM series Power Analyzer
E 3.2.2 Energy Management Software
E 3.3 Power Quality Recorders
E 3.3.1 2400d series Power Quality Recorder
E 3.3.2 2400ip series Power Quality Recorder
E 3.3.3 2400R series Power Quality Recorder
E 3.3.4 2400duo series Power Quality Recorder
E 3.3.5 2400i series Power Quality Recorder
E 3.4 Electricity Meters
E 3.4.1 MT860 Electricity meter for Transmission & Production
E 3.4.2 MT830 Electricity meter for Distribution & Industry
E 3.4.3 MT372 Electricity Meter for Small Size Commercial Subscribers
E 3.4.4 MT173 Electricity Meter for Small Size Commercial Subscribers
E 4 Measuring Transformers
E 4.1 Current Transformers
E 4.2 Voltage Transformers
82
84
84
84
86
86
86
86
87
87
88
88
88
88
88
88
89
90
90
91
91
92
92
92
92
93
93
93
93
93
93
94
94
94
94
94
95
95
95
Auxiliary
Equipment
E 1
Auxiliary Equipment Switching Equipment
E 1 Switching Equipment
E 1.1 Circuit Breakers
Aktif Elektroteknik use followings Vacuum or SF6 gas
insulated circuit breakers in air insulated medium voltage
Switchgears in conformity with IEC 62271-100 standards.
1.1.1 SVC (Aktif) Vacuum Circuit Breaker (are manufactured
up to the capacities of 40.5 kV, 3150A, 31.5 kA and are used
in the production).
1.1.2 SION/3AH (Siemens) Vacuum Circuit Breakers
1.1.3 EVOLIS (Schneider) Vacuum Circuit Breakers
1.1.4 SF1 type (Schneider) SF6 gas insulated Circuit Breakers
1.1.5 SF2 type (Schneider) SF6 gas insulated Circuit Breakers
E 1.1.1 SVC series Vacuum Breakers
SVC series Vacuum Circuit breakers are designed by Aktif
and their patent is obtained. In this manner the Switchgears
and breakers are supplied from one source.
Three pieces excellent insulated high quality Vacuum
interrupters are used In SVC series Vacuum Circuit breakers
as placed inside a special casing.
7
5
4
A
D
D
8
1
B
2
9
6
3
C
E
1.
2.
3.
4.
5.
6.
7.
8.
9.
Label
Interlock arm
Auxiliary carrying support
Contacts
Mechanism box
Push mechanism
Busbar shell
Tube protector
48 pin plug
A
B
C
D
E
84
a Friem & Aktif Group Company
3,6kV
200
320
775
700
640
7,2kV
200
320
775
700
640
12kV 17,5kV 24kV
200
200
200
320
320
320
775
775
775
700
700
700
640
640
640
36kV 40,5kV
350
350
455
455
1150 1150
930
930
960
960
Auxiliary Equipment Switching Equipment
E 1
The SVC units have compact structures and provide sturdy,
safe mechanical operation.
SVC series Vacuum Circuit Breakers are also designed as
drawer type.
The electrical arc is insulated in the vacuum environment and
extinguished within the vacuum. When an internal arc formed,
the extinguishing process takes place within the vacuum tube;
hence there would not be any release to the outside. The
vacuum tube does not need any maintenance. Due to its
general characteristics its contact structure would not be
deteriorated. Therefore it can be used more efficiently when
compared to similar products.
E 1.1.1.1 Application Areas
SVC units are used in the following application areas:
Overhead transmission lines
Distribution and transformer centers
Cables
Transformers
Motors
Generators
Capacitor banks
E 1.1.1.2 Advantages
Fulfilling committed energy targets
Excellent performance
Excellent Endurance
Long operation life
Low maintenance cost (fast and economic maintenance)
Technical Specifications:
Description
Rated Voltage (Ur)
1 minute high frequency withstand voltage (Ud)
Power frequency
Lightning
impulse withstand voltage (Up)
withstand Voltage
Rated Frequency (Fr)
Rated Current (Ir)
Rated short time withstand current(lk)
Rated short time withstand current(lp)
Operational sequence
Capacitive load switching current (lc)
Closing time
Opening time
Process time
Mechanical Life
Rated control circuit voltage
Operational temperature
Unit
kV
kV
kV
Hz
A
kA/3s
kA
A
ms
ms
ms
op.
V
C°
Values
3,6
7,2
12 17,5
24
36 40,5
10
85
20
28
38
50
70
40
60
75
95 125 170 190
50 / 60
630 - 1250 - 1600 - 2000 - 2500 - 3150
16 - 25 - 31,5
16 - 25
40 - 63 - 80
40 - 63
O - 0,3s - CO - 180s - CO
400
35 - 60
40 - 50
60
20.000
DC: 24, 110 / AC: 220
-5°...+40°
85
a Friem & Aktif Group Company
E 1
Auxiliary Equipment Switching Equipment
E 1.1.2 SION/3AH (Siemens) Vacuum Circuit Breaker
The vacuum breakers are subjected to routine tests during
production and these tests are harder than the
requirements of the standards.
Current measurement data flow
Decisive measurement data
Low power loss
Long term thermal stability
The vacuum circuit breakers do not need maintenance
Under normal operational conditions, 10000 opening and
closing as per IEC 60694 and VDE 0670 part 1000
The performance remains within the limits even in frequent
usage after long term stand-by periods
Environmentally sensitive.
E 1.1.3 EVOLIS (Schneider) Vacuum Circuit Breaker
Evolis vacuum breakers have 3 poles and they are for
internal use. This kind of circuit breaker is used for the
switching and protection purposes in the industry, public
sector and energy distribution.
These types of breakers are suitable for LSC2B type metal
partitioned metal clad sells.
Rated Voltage
: up to 24 kV
Rated Current
: up to 2500 A
Short Circuit switching Current : up to 40 kA
E 1.1.4 SF1 type (Schneider) SF6 Gas insulated Circuit Breaker
SF1 with 3 poles is for medium voltage internal usage. Between
1 kV and 40.5 kV, this kind of circuit breaker is used for the
switching and protection purposes in the industry, public sector
and commercial distribution. The SF1 breaker equipped with
automated compression technique and uses SF6 gas during
current cutting phase. There are 3 types of SF1:
Horizontal type suitable for metal enclosed LSC2A
Switchgears
Rated Voltage
: up to 40.5 kV
Rated Current
: up to 1250 A
Short Circuit switching Current : up to 25 kA
E 1.1.5 SF2 type (Schneider) SF6 Gas insulated Circuit Breaker
SF2 with 3 poles is for medium voltage internal usage. Between
24 kV and 38 kV, this kind of circuit breaker is used for the
switching and protection purposes in the industry, public sector
and commercial energy distribution. These types of breakers
are suitable for LSC2B metal clad Switchgears.
Rated Voltage
: up to 40.5 kV
Rated Current
: up to 2500 A
Short Circuit switching Current : up to 31.5 kA
86
a Friem & Aktif Group Company
Auxiliary Equipment Switching Equipment
E 1
E 1.2 Vacuum Contactors
The vacuum contactors have 3 poles and have cycle capacity
of over 1 million in the medium voltage facilities with their high
electromagnetic characteristics.
The vacuum contactors are also performed for alternative
current facilities for the below given purposes:
Motor start-up
Switching of transformers
Switching of reactors
Switching of big resistive loads similar to those in electric
furnaces
Switching of capacitor banks
E 1.3 Load Break Switches
SLB series Load Break Switches used are in conformanity with
IEC 60295-1 and 62271-102 standards and load break switches
are able to switch the circuit on load. The rated current is up to
630 A and the short circuit withstand is up to 20 kA.
The Load Break Switch has SF6 gas and it switches on load.
It has 3 poles and 3 modes (open - close - earthed). The
Earthing Disconnector is located in Load Break Switch
structure.
E 1.4 Disconnectors
In close position
In open position
Grounding
E 1.4.1 SF6 gas insulated Disconnectors
SGD series SF6 gas insulated Disconnectors are used in
conformity with IEC 60295-1 and 62271-102 standards. The
rated current is up to 1250 A and the short circuit withstand
is up to 25 kA.
Furthermore, it has SF6 gas and it has opening and closing
feature without load. It has 3 poles and 3 modes (open close - earthed). The Earthing Disconnector is located in
Load Break Switch structure.
E 1.4.2 Air insulated Rotary Switches
SRS series Air Insulated Rotary Switches have rated current
of up o 1250 A and short circuit withstand current of up to 25
kV and are used in Metal Enclosed Switchgears.
E 1.5 Earthing Disconnectors
SES series earthing switches are manufactured and
produced with 3 second withstand up to 31.5 kA and 1
second withstand up to 50 kA.
87
a Friem & Aktif Group Company
E 2
Auxiliary Equipment Protection Devices
E 2 Protection Devices
E 2.1 Relays
Microelettrica Scientifica secondary protection relays are used
in our products. These relays are digital and able to provide
protection in different applications and functions. These relays
have Modbus RTU, IEC 60870-103 or IEC 61850 communication
protocols; are classified as M series, MC series, Ultra series
and DTVA series. The protection functions that can be done
with these relays are;
Current & Voltage protection
Feeder, Line and Busbar protection
Transformer protection
Motor and Generator protection
Capacitor feeder protection
In addition to these protection functions, trip and event recording
can also be obtained. These relays provide easy to use feature with
their draw-out execution. Relays can communicate with MSCom2,
Actwin RM and any Scada software.
E 2.1.1 M series
These relays are microprocessor based and are used in high
and medium voltage systems.
They have Modbus RTU communication protocol and R485
serial communication port at the back.
E 2.1.2 MC series
Different protection features are combined in these relays
due to its compact structure.
They have one R485 serial communication port at the back
and there is one RS232 serial communication port on the
front panel.
E 2.1.3 ULTRA series
These relays can be used in any application in transmission,
distribution and industrial plants.
It combines protection, measurement and control features.
In addition to R485 serial communication port at the back
and one RS232 serial communication port on the front panel,
Modbus RTU/IEC60870-5-103/IEC61850/TCP-IP
communication protocols are also presented.
E 2.1.4 DTVA series
These relays make distance protection in 3 phase, phase to
phase and phase to ground faults.
These relays are distance protection relays that have auto
reclosing function.
The communication can be done by RS232 from the front panel
and by fiber optic connection from the rear of the equipment.
These relays have the functions of remote testing by a
computer,collecting the measured values and setting.
88
a Friem & Aktif Group Company
Auxiliary Equipment Protection Devices
E 2
E 2.1.5 ANSI codes Application Tables
DLMR
DM30-S
DM33
DTMR
DTMR-3
DTVA-EP
FMR
GMR
IM30-AB
IM30-AP
IM30-B00
IM30-BY
IM30-C
IM30-D
IM30-DT
IM30-G
IM30-SA
IM30-SR
IM30-T
MC1V
MC3V
MC20
MC30
MC30-R
MC30-RG
MCM
MD32-G
MD32-T
MD33-T
MFP
MG30
MMR
MM30
MM30-D
MM30-W
MTR33
MW33
M-HIB3
M-LIB3
RIA123
SCM21
SPM21
UM30-A
UFD14
UFD34
Sekonder Koruma Röleleri Genel Uygulama Tablosu
Speed Control
Distance protection / Under impedance
Volts per Herz
Synchronization and/or synchrocheck
Under Voltage (AC)
Under/over Voltage (AC)
Under/over voltage of positive sequence
Directional Power
Under current or under power
Loss of field
Reverse phase or phase balanced current
Unbalanced protection for capacitors
Phase sequence or phase balance voltage
Control of motor starting sequence
Thermal protection for machine or trafo
Instantaneous / time delayed over current
Instantaneous / time delayed earth fault
Voltage restrained over current
Breaker failure protection
Locked rotor protection
Power factor
Over voltage (AC)
Zero sequence over voltage
Fuse failure
Ground fault protection (insulation)
Machine stator ground fault
Sensitive earth fault protection
Control of motor starting number
AC directional over current relay
Directional earth fault relay
Blocking output
Trip circuit supervision
Phase angle or out of step protection
Reclosing
Frequency
Lock-out
Differential protection
Pilot cable differential protection
Busbar differential protection
Differantial earth fault current
Regulating control
Frequency rate of change
Voltage rate of change
Breaker interruption energy
Oscillographic waveform capturing
Automatic threshold doubling on inrush
Double setting
12 /14
21
24
25
27
27/59
27/59d
32
37
40
46
46N
47
48
49
50/51
50/51N
50/51V
51BF
51LR
55
59
59Uo
60FL
64
64S
64SEF
66
67
67N
68
74
78
79
81
86
87
87/85
87B
87N
90
df/dt
dv/dt
I2t
Osi
2xIn
2-set
Note: This table is prepared by taking into consideration of frequently used relays. There are a lot of relays
applicablefor protection functions that are not listed here being used. Please ask for a copy of detailed
product catalogue for other relays and protection functions that are not listed in this table.
89
a Friem & Aktif Group Company
E 2
Auxiliary Equipment Protection Devices
E 2.1.6 Relay Management Software
MSCom2
It communicates with any Microelettrica Scientifica relays.
Real time measurement and all system and function settings
are possible.
It can communicate with up to 250 relays.
Firmware update is available.
Free of charge.
Real time measuring can be performed.
ActWin RM
It is developed for remote monitoring and control of the relays.
GPRS and RS485 communications are available.
All events, alarms and all other operations are recorded.
It provides protection against unauthorized interference with
its three level of authorization scheme.
Monitoring and control over the mobile phones and
computers are available.
Drawing a single line diagram and displaying relay on it, is
provided.
Actwin Mobile
It is the Mobile phone version of ActWin RM.
E 2.2 Fuses
The fuses that are used in our products safely protect the
transformers, cable, capacitor banks against thermal effects
and short circuits between the 6 kV and 36 kV.
Appropriate circuit breaker selection can be made by using
below provided reference table.
TransRated Voltage U1N= 20/24 kV U2N = 400V Rated Voltage U1N= 30/36 kV U2N = 400V
former Rated Voltage U1N= 17,5 kV U2N = 400V
Rated
Transformer MV Rated
MV Rated
LV Rated
MV Rated
LV Rated
LV Rated
Transformer
Power Transformer
(KVA) Rated Current Fuse Current Fuse Current Rated Current Fuse Current Fuse Current Rated Current Fuse Current Fuse Current
25
50
75
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
prim.
(A)
sec.
(A)
min.
(A)
max.
(A)
min.
(A)
max.
(A)
prim.
(A)
sec.
(A)
min.
(A)
max.
(A)
min.
(A)
1,0
1,9
2,9
3,8
4,8
6,2
7,7
9,6
12,1
15,4
19,2
24,2
30,8
38,5
48,1
61,6
77,0
36
72
108
144
180
231
289
361
455
577
722
909
1155
1443
1804
2309
2887
4
6,3
10
10
16
16
20
25
25
25
31,5
40
63
80
100
125
160
6,3
10
10
16
20
25
25
31,5
31,5
40
50
63
80
100
100
125
160
40
31,5
80
63
100 125
125 160
160 200
200 250
250 315
315 400
400 500
500 630
630 720
800 900
1000 1200
1200
-
0,7
1,4
2,2
2,9
3,6
4,6
5,8
7,2
9,1
11,5
14,4
18,2
23,1
28,9
36,1
46,2
57,7
36
72
108
144
180
231
289
361
455
577
722
909
1155
1443
1804
2309
2887
4
6,3
6,3
10
10
16
16
20
20
25
31,5
40
50
63
80
100
125
6,3
6,3
6,3
10
16
20
20
25
25
40
50
63
63
80
80
100
125
40
31,5
80
63
100 125
125 160
160 200
200 250
250 315
315 400
400 500
500 630
630 720
800 900
1000 1200
1200
-
90
a Friem & Aktif Group Company
max.
(A)
prim.
(A)
sec.
(A)
min.
(A)
max.
(A)
0,5
1,0
1,4
1,9
2,4
3,1
3,8
4,8
6,1
7,7
9,6
12,1
15,4
19,2
24,1
30,8
38,5
36
72
108
144
180
231
289
361
455
577
722
909
1155
1443
1804
2309
2887
6,3
2
6,3
4
6,3
6,3
6,3
6,3
10
6,3
16
10
16
10
20
16
25
16
25
16
25 31,5
40
31,5
50
40
50
40
63
50
80
63
2x50
min.
(A)
max.
(A)
31,5
63
100
125
160
200
250
315
400
500
630
800
1000
1200
-
40
80
125
160
200
250
315
400
500
630
720
900
1200
-
Auxiliary Equipment Measuring Devices
E 3
E 3 Measuring Devices
E 3.1 Capacitive voltage indicators
The voltage indicators that we use in our products work on
the principle of measuring of capacitive voltage.
It provides excellent results in displaying the presence of the
voltage without supply.
They are manufactured according to IEC 61243-5 standard.
Technical Specifications
Standards
Display of Phase
: IEC 61243-5
: No display U<%10 Un
Led light on U>%10 Un
o
o
Operational Temperature Range : -25O C … +70O C
o
o
Storage Temperature Range
: -30O C … +80O C
Protection Class
: IP 54
91
a Friem & Aktif Group Company
E 3
Auxiliary Equipment Measuring Devices
E 3.2 Power & Energy Analyzers
Analyzers combine voltmeter, cosphimeter, wattmeter,
var-meter and frequency-meter into single equipment.
Therefore, it is possible to make savings from space, cable
and cost of equipment.
The data read can be transferred to SCADA or energy
Management Software on a computer via communication
ports that on the equipment. Since this data is kept in the
data base of the equipment, it provides simplicity in fault
determination. Furthermore consumption figures for the
past periods can be obtained hence planning towards future
can be made more consistently.
Due to digital outputs provided by the equipment it has
became indispensible part of SCADA systems. Transducer
usage becomes unnecessary by the help of some models
which have analog outputs.
Due to these features, the analyzers become essential part
of any management or automation system.
E 3.2.1 NQM series Energy Analyzers
Large 128 x 128 graphic LCD
Embedded memory for measurements records (with
extendable memory)
Programmable digital outputs (maximum 6)
Digital inputs may be used as a counter (for gas and water
meters) and position monitoring (maximum 8)
Programmable analog outputs (maximum 4)
RS232 and RS485 communication ports
Current and voltage waveform display on the screen
Harmonic analysis
Faulty connection warning
E 3.2.2 NPM series Power Analyzer
RS485 communication port
4 LED screen that can be read remotely
Display of more than 30 electrical parameter
E 3.2.3 Energy Management Software
Actwin Energy Management Software reads all energy
parameters of Asset Power Analyzers and digital Electricity
Meters and records the data with time labels. It supports various
communication interfaces as well as communication protocols.
With different reporting and monitoring screens, various reports
and invoices can be created by the parameters recorded and can
be viewed in different formats in real time.
The most important feature of the software is that the data reading is
possible from multiple ports simultaneously and this increases
communication speed to a maximum level. In this manner, it is possible
to obtain more reading and create much more detailed reports.
92
a Friem & Aktif Group Company
Auxiliary Equipment Measuring Devices
E 3
E 3.3 Power Quality Recorders
Energy quality recorders are the necessary equipment for
analyzing the quality of electric networks according to
related standards (EN 50160, IEC 6100-4-7). The various
electrical parameters such as flickers, harmonics,
inter-harmonics, symmetric components, instability and
energy can be monitored simultaneously.
According to EN 50160, IEC 61000-3-6/7 standards, all
statistical data relating to quality of the energy of the
distribution and transmission systems including voltage sag,
swell and interruptions and so on are recorded by IEC
61000-4-30 class A and detailed reporting in conformity with
the standards are made.
E 3.3.1 2400d Series Power Quality Recorder
DIN rail type, compact structure, suitable for placing in a panel.
Without an external connection, assembled solutions
RS232 and USB connection
GPS and pulse synchronization
Screwed input terminal blocks
Ethernet and website interface
PSTN and GSM/GPRS modem
DC insulated 4 current and 4 voltage measurement inputs in
2444d model
Only 4 voltage measurement inputs in 2440d model
E 3.3.2 2400ip Series Power Quality Recorder
Suitable design for heavy conditions
IP 65 protection class against water, dust and impacts
4 voltage and 4 current measurement inputs
Water proof connections
Wall mounted type structure and flush mounting
E 3.3.3 2400R Series Power Quality Recorder
The best protection and safety level in its own class
Galvanized insulated 4 voltage and 4 current measurement inputs
Screw type connections to the terminal blocks that provides
maximum level of safety
Strengthened battery for 3 hours of operation
E 3.3.4 2400duo Series Power Quality Recorder
Measuring two transformers' parameters simultaneously at
transmission and distribution substations or in industrial plants
DC insulated 8 current and 8 voltage measurement inputs
Screw type connections to the terminal blocks that provides
maximum level of safety
E 3.3.5 2400i Series Power Quality Recorder
4 current and 4 voltage measurement input
High speed communication
93
a Friem & Aktif Group Company
E 3
Auxiliary Equipments Measuring Devices
E 3.4 Electricity Meters
Unless otherwise required, static electric meters are used in
our products and meters with appropriate features and
certifications are chosen for different applications.
E 3.4.1 MT860 Electricity Meter with High Accuracy for
Transmission and Production Plants
Class 0.2S active energy measurement accuracy
Active, reactive and apparent energy/demand measurement
Modular communication and input/output options
Sag/swell and interruption measurements
Leakage detection and recording function
Due to the optic probe, there is no need to energy for reading
Various communication alternatives (RS485, GSM/GPRS,
Ethernet)
E 3.4.2 MT830 Electricity Meter for Distribution and
Industrial plants
Class 0.5s active energy measurement accuracy
Active, reactive and apparent energy/demand measurement
In conformity with the EPDK technical specifications
Energy interruption counter
Harmonic component analysis
Leakage detection and recording function
Various communication alternatives (RS485, GSM/GPRS,
Ethernet)
E 3.4.3 MT 372 Electricity Meter for Small Size Commercial
Subscribers
Class 1 active energy measurement accuracy
Active, reactive and apparent energy/demand measurement
Suitable for pre-paid subscriptions with internal cut-off
device
Internal GPRS modem option
Possibility of reading water and gas meters with MBus output
Various communication alternatives (RS485, GSM/GPRS,
Ethernet, MBus)
E 3.4.4 MT173 Electricity Meter for Small Size Commercial
Subscribers
Class 1 active energy measurement accuracy
Active, reactive and apparent energy/demand measurement
Network/generator tariffs
Different tariffs during the day (Day, night, peak time)
RS485 communication port
94
a Friem & Aktif Group Company
Auxiliary Equipments Measuring Transformers
E 4
E 4 Measuring transformers
We use, depending on the requirement, either conventional
type measurement transformers in conformity with IEC
60044-1 and IEC 60044-2 or Rogowski type cast resin
measurement transformers in conformity with IEC 60044-8.
E 4.1 Current transformers
Current/Voltage slope is extremely linear and does not get
saturated
Can work in many different frequencies
Since it does not have iron core, fast current change and
transient response is very well.
Decreases the interaction due to magnetic field.
Rogowski and Conventional type of current transformers
are used in SME series switchgears.
Internal Type - with supports /bushings
Internal Type - with capacitive layers
External Type
Basic Specifications
Operational voltage
Withstand voltage
Short period testing voltage (1.2/50ºs)
Rated frequency
Rated primer current
Secondary coils
Short period thermal withstand current (1s)
Insulation Class
: up to 40.5 kV
: up to 85 kV
: up to 185 kV
: 50 / 60 Hz
: up to 4000 A
:1/5A
: up to 1000 In
:E
E 4.2 Voltage transformers
The cast resin coated conventional voltage transformers
used in our products are as follow:
Internal type single pole insulated with circuit breaker
Internal type single pole insulated without circuit breaker
Internal type double pole insulated
Basic Specifications
Operational voltage
Withstand voltage
Short period testing voltage (1.2/50ºs)
Rated frequency
Rated primer current
Secondary Voltage
Class
Nominal gerilim faktörü
Insulation Class
: up to 40.5 kV
: up to 85 kV
: up to 185 kV
: 50 / 60 Hz
: up to 40.5/√3 kV
: 100/√3 V, 110/√3 V,
120/√3 V
: 0,2 / 0,5 / 1
: 1,9
:E
95
a Friem & Aktif Group Company
Raylı Sistemler
Orta Gerilim Hücreler
Enerji Da€›tım Çözümleri
Trafo ve Da€›t›m Kö kleri
Depo Alanı Çözümleri
Mobil ‹stasyonlar
Araçüstü Ekipmanlar
Dirençler
Enerji Kalitesi
OSOS ve Faturalama
T›bbi Güç Sistemleri
Senkronizasyon Cihazlar›
Sekonder Koruma Röleleri
Ölçme ve Yönetim Sistemleri
Kaçak Akım Röleler
Microener – 49 rue de l’Université – 93160 Noisy le Grand – France
a Friem & Aktif Group Company
Tél : 01 48 15 09 09 – E-mail : info@microener.com – www.microener.com
Doc. Nr. AET-SW 1105/C.Eng Owing to periodical improvements of our products the supplied products may differ in some details from the data stated in the prospectus material. Published by Aktif Elektroteknik A.S. Data subject to alteration without notice.
Design & Creation: Aktif Group / Photos: Aktif Group - Stock.xchng & Shutterstock
Enerji ve Endüstri
Download